Date post: | 04-Feb-2018 |
Category: |
Documents |
Upload: | vuongnguyet |
View: | 235 times |
Download: | 2 times |
Ascotherm® eco KRP91Natural convection
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 5
Asc
othe
rm e
co
KRP
91
Tender specification, range available and sizes
Operating principle
Cold air from the window area and cool room air drop in the floor pan. The air is heated by the heat regi-ster, becomes lighter and rises. Due to the installation in front of window areas a specific shielding against cold air is provided. For more information, see chapter "General information".
Tender specification
Version KRP91 Natural Convection
Ready-to-install floor pan for the floor area. Operating principle natural convection.
Sturdy floor pan made of galvanised sheet steel, coated in anthracite grey (RAL 7016), external, adjustable and acoustically decoupled height adjustments (pre-installed).
Heat register consisting of copper pipes and aluminium fins, an-thracite grey (RAL7016) coated and mounted in transversal steel girders made of galvanised sheet steel, acoustically decoupled.
Standard on the face or room side euro taper connection with union nut (3/4“ internal thread) and air vent. Suitable for a max. operating pressure of 10 bar (optionally 16 bar) and a max. operating temperature of 110 °C.
Aluminium linear grille as standard. Acoustic decoupling through placement of the aluminium linear grille on rubber ele-ments in the floor pan. Consisting of sturdy longitudinal profile bars, natural colour anodised, with profile bar dimensions of 16 x 6 mm. Grille with a total height of 20 mm and an open cross-section of 60%.
Including installation cover and edge bar protection for protec-ting the trench convectors during the construction phase.
Heat outputs tested and determined in acc. with Pr DIN EN 16430, Part 1 and 2.
QA system certified according to DIN EN ISO 9001:2008.
Environmental management system according to DIN EN ISO 14001:2004.
Suitable for closed water heating systems in accordance with DIN 18380 and water quality in accordance with VDI 2035, ÖNORM H5195 and SWKI BT 102-01.
Operating conditions: Hot water up to 110 °C
Operating pressure: Max. 10 bar (optionally 16 bar high-pres-
sure-version)
Test pressure: 13 bar (21 bar)
GeneralTrench convectors find application in private residential areas, in conservatories, in offices and administration buildings, in show-rooms as well as in business premises.
Version KRP91 Natural Convection
• Connections: 2 x euro taper with union nut (3/4“ internal thread), suitable for use with all fittings that comply with DIN V 3838
• Air vent: installed
Range available• 6 depths: 185, 210, 260, 310, 360 and 400 mm• 4 heights: 92, 120, 150 und 200 mm• 17 lengths:
– from 1000 mm to 5000 mm– Grading 250 mm
• Standard: Aluminium linear grille
Surface finishes• Standard colour of floor pan, powder-coated:
Anthracite grey (RAL7016 matt finish)• Standard colour of linear grille:
Aluminium anodised in natural colour• Standard colour of edge bar:
Aluminium, anodised in natural colour
Accessories• Digital room thermostat• Programmable room thermostat• Electric actuator 230 V AC• Room thermostat with remote control• Connection set, consisting of valve base with factory preset kV
valve and return fitting with shut-off
For additional accessories and information about accessories, see "Accessories".
6 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Ascotherm KRP91Natural convection
Asc
othe
rm e
co
KRP
91
Technical data per metre
Technical data per metreHeight 92-200 mm
HeightH
[mm]
DepthT
[mm]
Heat output
Expo-nent
n[ ]
Spec.standard
waterflow rate
qms[kg/h m]
Massper
metre(average)
M[kg/m]
ΦL ∆T 50K75/65/20°C[watts/m
ribbedconvector
length]
Φ ∆T 42K70/55/20°C[watts/mribbed
convectorlength]
Φ ∆T 30K55/45/20°C[watts/mribbed
convectorlength]
Φ ∆T 25K50/40/20°C[watts/mribbed
convectorlength]
92
185 288 220 126 93 1,60 24,8 9,01
210 315 248 151 116 1,42 27,2 9,98
260 368 289 176 135 1,43 31,7 11,78
310 473 377 238 186 1,33 40,8 13,72
360 567 451 282 219 1,35 48,9 15,89
400 630 503 317 247 1,33 54,3 17,01
120
185 354 273 161 121 1,53 30,5 10,02
210 389 306 187 143 1,42 33,5 11,06
260 473 371 226 173 1,43 40,8 12,98
310 567 444 269 206 1,44 48,9 15,06
360 662 519 316 242 1,43 57,1 17,33
400 735 578 353 271 1,42 63,4 18,53
150
185 420 323 189 141 1,55 36,2 11,50
210 554 434 263 201 1,44 47,8 12,87
260 662 516 310 235 1,47 57,1 14,80
310 767 600 363 277 1,45 66,1 17,22
360 859 669 402 305 1,47 74,1 19,95
400 945 733 435 329 1,50 81,5 21,06
200
185 509 393 232 175 1,52 43,9 13,00
210 610 477 288 220 1,45 52,6 14,41
260 725 566 341 260 1,46 62,5 16,41
310 872 681 410 312 1,46 75,2 18,89
360 1128 880 530 404 1,46 97,2 21,69
400 1307 1017 608 462 1,48 112,7 22,85
For individual calculations of heat outputs, see "General Information"
Ascotherm® eco KRP91Natural convection
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 7
Asc
othe
rm e
co
KRP
91
Dimensional drawings and connection images
2-pipe connections without integrated valve
Connection system
Orde-ring code IVTI
ArrangementOrdering code
|ANB|
Connec-tionsize
Ordering code
Additio-nal price
per radiator [EUR]|VG| |RG|
2-pipe, room side, side by side
2 BB DDEuro taper with union
nut internal thread
3/4“
64 64 –
2-pipe, on the face side, side by side
2 11 33
2-pipe, facing down, side by side
2
Special connection 66/ 88
The accessories range does not contain any connection sets with preset valves for the connection arrangements 66 and 88; however, these can be installed at the factory with appropriate notification when ordering.
Valve base with factory preset kv valve = Outflow 3/4“ external thread with euro taper, inflow 1/2“ internal thread; return fitting with shut-off: both sides 3/4“ external thread with euro taper
On request
Dimensional drawings KRP91
Connection BB/DD
Side view from left Front view Side view from right
H1
T
T-33 H2
H3
H
36106 50
L
Ø19
Ø33
Top view
Lber.
Dimensional drawings for connection BB, connection DD mirrored
T [mm]
H [mm]
H1 [mm]
H2 [mm]
H3 [mm]
185
210
260
310
360
400
92 3 - 30 61 61
120 3 - 50 61 86
150 3 - 85 61 111
200 3 - 105 86 136
L [mm]
Lribb. [mm]
up to 3000 L - 278
over 3000 L - 360
ribb.
Ascotherm® eco KRP91Natural convection
8 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Asc
othe
rm e
co
KRP
91
Dimensional drawings and connection images
Dimensional drawings KRP91
Connections 11/33
Side view from left Front view Side view from right
T
T-33
T1 NA
Ø19
Ø33
T2
H1
H2
H3
H
L
Top view
Lber.
Dimensional drawings for connection 11, connection 33 mirrored
T [mm]
H [mm]
H1 [mm]
H2 [mm]
H3 [mm]
185
210
260
310
360
400
92 3 - 30 61 61
120 3 - 50 61 86
150 3 - 85 61 86
200 3 - 105 86 111
T [mm]
T1 [mm]
T2 [mm]
Boss spa-cing [mm]
185 38 92 100
210 38 117 100
260 38 142 112,5
310 88 192 112,5
360 126 237 100
400 151 269 100
L [mm]
Lribb. [mm]
up to 3000 L - 278
over 3000 L - 360
Pressure loss diagram for heights 92 and 120 mm Pressure loss diagram for heights 150 and 200 mm
Pres
sure
loss
∆p
[m
bar
/m r
ibb
ed c
on
vect
or
len
gth
]
T 185, T 210
T 260T 310
T 400
T 360
1
10
100
10 100 1000
Pres
sure
loss
∆p
[m
bar
/m r
ibb
ed c
on
vect
or
len
gth
]
T 185, T 210
T 260
T 310T 400
T 360
1
10
100
10 100 1000
Water flow qm [kg/h] Water flow qm [kg/h]
ribb.
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 9
Asc
othe
rm e
co
KRP
91
LR: Aluminium linear grille, natural colour anodised (standard)
Ribbed convector length = length floor pan - 278 mm, for length > 3000 mm: length floor pan - 360 mm
Standard heat output at 75 / 65 / 20 °C (∆T 50K), Φ=ΦS
Ascotherm® eco KRP91Natural convection
Prices and heat outputs
Height 92 mm (depth 185–260 mm)
Version KRP91 KRP91 KRP91Depth T [mm] 185 210 260Exponent n [ ] 1,60 1,42 1,43Price per piece [EUR/pc.] 87,14 119,18 124,15
Price per metre [EUR/m]without linear
grille
113,12
with linear grille
204,04
without linear grille
160,60
with linear grille
256,25
without linear grille
161,09
with linear grille
269,72
LengthL
[mm]
Ribbedconvector length
Lribb. [mm]
∆T[K]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
1000 722504230
20815991
200,26 291,18227178109
279,78 375,43266209127
285,24 393,87
1250 972504230
280213122
228,54 342,19306240147
319,93 439,49358281171
325,51 461,30
1500 1222504230
352268154
256,82 393,20385303185
360,08 503,56450353215
365,79 528,73
1750 1472504230
424323185
285,10 444,21464365223
400,23 567,62542425259
406,06 596,16
2000 1722504230
496378217
313,38 495,22542426260
440,38 631,68634497303
446,33 663,59
2250 1972504230
568433248
341,66 546,23621488298
480,53 695,74726570347
486,60 731,02
2500 2222504230
640488280
369,94 597,24700550336
520,68 759,81818642391
526,88 798,45
2750 2472504230
712543311
398,22 648,25779612374
560,83 823,87910714435
567,15 865,88
3000 2722504230
784598343
426,50 699,26857673411
600,98 887,931002786479
607,42 933,31
3250 2890504230
832634364
454,78 750,27910715437
641,13 951,991064835508
647,69 1000,74
3500 3140504230
904689395
483,06 801,28989777475
681,28 1016,061156907552
687,97 1068,17
3750 3390504230
976744427
511,34 852,291068839513
721,43 1080,121248979596
728,24 1135,60
4000 3640504230
1048799458
539,62 903,301147901551
761,58 1144,1813401051640
768,51 1203,03
4250 3890504230
1120854490
567,90 954,311225963588
801,73 1208,2414321123684
808,78 1270,46
4500 4140504230
1192909521
596,18 1005,3213041025626
841,88 1272,3115241196728
849,06 1337,89
4750 4390504230
1264963553
624,46 1056,3313831087664
882,03 1336,3716161268772
889,33 1405,32
5000 4640504230
13361018584
652,74 1107,3414621149702
922,18 1400,4317081340816
929,60 1472,75
10 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Asc
othe
rm e
co
KRP
91
LR: Aluminium linear grille, natural colour anodised (standard)
Ribbed convector length = length floor pan - 278 mm, for length > 3000 mm: length floor pan - 360 mm
Standard heat output at 75 / 65 / 20 °C (∆T 50K), Φ=ΦS
Ascotherm® eco KRP91Natural convection
Prices and heat outputs
Height 92 mm (depth 310–400 mm)
Version KRP91 KRP91 KRP91Depth T [mm] 310 360 400Exponent n [ ] 1,33 1,35 1,33Price per piece [EUR/pc.] 141,38 157,62 164,92
Price per metre [EUR/m]without linear
grille
167,49
with linear grille
299,74
without linear grille
215,53
with linear grille
361,95
without linear grille
213,51
with linear grille
370,85
LengthL
[mm]
Ribbedconvector length
Lribb. [mm]
∆T[K]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
1000 722504230
342273172
308,87 441,12409325204
373,15 519,57455363229
378,43 535,77
1250 972504230
460367231
350,74 516,06551438274
427,03 610,06612488308
431,81 628,48
1500 1222504230
578461291
392,62 590,99693551345
480,92 700,55770614387
485,19 721,20
1750 1472504230
696555350
434,49 665,93835664416
534,80 791,03927740466
538,56 813,91
2000 1722504230
815650410
476,36 740,86976776486
588,68 881,521085866546
591,94 906,62
2250 1972504230
933744469
518,23 815,801118889556
642,56 972,011242991625
645,32 999,33
2500 2222504230
1051839529
560,11 890,7312601002627
696,45 1062,5014001117704
698,70 1092,05
2750 2472504230
1169933588
601,98 965,6714021115698
750,33 1152,9815571242783
752,07 1184,76
3000 2722504230
12881028648
643,85 1040,6015431227768
804,21 1243,4717151369862
805,45 1277,47
3250 2890504230
13671091687
685,72 1115,5416391303816
858,09 1333,9618211453916
858,83 1370,18
3500 3140504230
14851185747
727,60 1190,4717801416886
911,98 1424,4519781578995
912,21 1462,90
3750 3390504230
16031279806
769,47 1265,4119221528957
965,86 1514,93213617041074
965,58 1555,61
4000 3640504230
17221374866
811,34 1340,34206416411027
1019,74 1605,42229318301153
1018,96 1648,32
4250 3890504230
18401468925
853,21 1415,28220617541098
1073,62 1695,91245119561233
1072,34 1741,03
4500 4140504230
19581562985
895,09 1490,21234718661168
1127,51 1786,40260820811312
1125,72 1833,75
4750 4390504230
207616571044
936,96 1565,15248919791239
1181,39 1876,88276622071391
1179,09 1926,46
5000 4640504230
219517521104
978,83 1640,08263120921309
1235,27 1967,37292323321470
1232,47 2019,17
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 11
Asc
othe
rm e
co
KRP
91
LR: Aluminium linear grille, natural colour anodised (standard)
Ribbed convector length = length floor pan - 278 mm, for length > 3000 mm: length floor pan - 360 mm
Standard heat output at 75 / 65 / 20 °C (∆T 50K), Φ=ΦS
Ascotherm® eco KRP91Natural convection
Prices and heat outputs
Height 120 mm (depth 185–260 mm)
Version KRP91 KRP91 KRP91Depth T [mm] 185 210 260Exponent n [ ] 1,53 1,42 1,43Price per piece [EUR/pc.] 110,52 144,49 156,95
Price per metre [EUR/m]without linear
grille
137,56
with linear grille
228,48
without linear grille
193,33
with linear grille
288,98
without linear grille
194,46
with linear grille
303,09
LengthL
[mm]
Ribbedconvector length
Lribb. [mm]
∆T[K]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
1000 722504230
256197116
248,08 339,00281221135
337,82 433,47342268163
351,41 460,04
1250 972504230
344265156
282,47 396,12378297181
386,15 505,72460361220
400,03 535,81
1500 1222504230
433334196
316,86 453,24475373228
434,49 577,96578453276
448,64 611,59
1750 1472504230
521402236
351,25 510,36573450275
482,82 650,21696546332
497,26 687,36
2000 1722504230
610471277
385,64 567,48670527322
531,15 722,45815639389
545,87 763,13
2250 1972504230
698538317
420,03 624,60767603368
579,48 794,70933732446
594,49 838,90
2500 2222504230
787607357
454,42 681,72864679415
627,82 866,941051825502
643,10 914,68
2750 2472504230
875675397
488,81 738,84962756462
676,15 939,191169917558
691,72 990,45
3000 2722504230
964744437
523,20 795,961059832508
724,48 1011,4312881010615
740,33 1066,22
3250 2890504230
1023789464
557,59 853,081124883540
772,81 1083,6813671072653
788,95 1141,99
3500 3140504230
1112858504
591,98 910,201221960586
821,15 1155,9214851165709
837,56 1217,77
3750 3390504230
1200926544
626,37 967,3213191037633
869,48 1228,1716031258766
886,18 1293,54
4000 3640504230
1289994585
660,76 1024,4414161113680
917,81 1300,4117221351822
934,79 1369,31
4250 3890504230
13771062624
695,15 1081,5615131189726
966,14 1372,6618401444879
983,41 1445,08
4500 4140504230
14661131665
729,54 1138,6816101265773
1014,48 1444,9019581536935
1032,02 1520,86
4750 4390504230
15541199705
763,93 1195,8017081342820
1062,81 1517,1520761629991
1080,64 1596,63
5000 4640504230
16431267745
798,32 1252,9218051418866
1111,14 1589,39219517221048
1129,25 1672,40
12 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Asc
othe
rm e
co
KRP
91
LR: Aluminium linear grille, natural colour anodised (standard)
Ribbed convector length = length floor pan - 278 mm, for length > 3000 mm: length floor pan - 360 mm
Standard heat output at 75 / 65 / 20 °C (∆T 50K), Φ=ΦS
Ascotherm® eco KRP91Natural convection
Prices and heat outputs
Height 120 mm (depth 310–400 mm)
Version KRP91 KRP91 KRP91Depth T [mm] 310 360 400Exponent n [ ] 1,44 1,43 1,42Price per piece [EUR/pc.] 181,95 216,91 227,76
Price per metre [EUR/m]without linear
grille
201,69
with linear grille
333,94
without linear grille
245,08
with linear grille
391,50
without linear grille
253,07
with linear grille
410,41
LengthL
[mm]
Ribbedconvector length
Lribb. [mm]
∆T[K]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
1000 722504230
409320194
383,64 515,89478375228
461,99 608,41531417255
480,83 638,17
1250 972504230
551432262
434,06 599,38643504307
523,26 706,29714561343
544,10 740,77
1500 1222504230
693543329
484,49 682,86809635386
584,53 804,16898706431
607,37 843,38
1750 1472504230
835654397
534,91 766,35974764465
645,80 902,041082850519
670,63 945,98
2000 1722504230
976764464
585,33 849,831140894544
707,07 999,911266995608
733,90 1048,58
2250 1972504230
1118876531
635,75 933,3213051024623
768,34 1097,7914491139696
797,17 1151,18
2500 2222504230
1260987599
686,18 1016,8014711154702
829,61 1195,6616331283784
860,44 1253,79
2750 2472504230
14021098666
736,60 1100,2916361284781
890,88 1293,5418171428872
923,70 1356,39
3000 2722504230
15431208733
787,02 1183,7718021414861
952,15 1391,4120011573961
986,97 1458,99
3250 2890504230
16391284779
837,44 1267,2619131501914
1013,42 1489,29212416691020
1050,24 1561,59
3500 3140504230
17801394846
887,87 1350,7420791631993
1074,69 1587,16230818141108
1113,51 1664,20
3750 3390504230
19221505913
938,29 1434,23224417601072
1135,96 1685,04249219581196
1176,77 1766,80
4000 3640504230
20641617981
988,71 1517,71241018911151
1197,23 1782,91267521021284
1240,04 1869,40
4250 3890504230
220617281048
1039,13 1601,20257520201230
1258,50 1880,79285922471372
1303,31 1972,00
4500 4140504230
234718381115
1089,56 1684,68274121501309
1319,77 1978,66304323911461
1366,58 2074,61
4750 4390504230
248919491182
1139,98 1768,17290622801388
1381,04 2076,54322725361549
1429,84 2177,21
5000 4640504230
263120611250
1190,40 1851,65307224101467
1442,31 2174,41341026801637
1493,11 2279,81
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 13
Asc
othe
rm e
co
KRP
91
LR: Aluminium linear grille, natural colour anodised (standard)
Ribbed convector length = length floor pan - 278 mm, for length > 3000 mm: length floor pan - 360 mm
Standard heat output at 75 / 65 / 20 °C (∆T 50K), Φ=ΦS
Ascotherm® eco KRP91Natural convection
Prices and heat outputs
Height 150 mm (depth 185–260 mm)
Version KRP91 KRP91 KRP91Depth T [mm] 185 210 260Exponent n [ ] 1,55 1,44 1,47Price per piece [EUR/pc.] 116,05 151,76 159,71
Price per metre [EUR/m]without linear
grille
156,80
with linear grille
247,72
without linear grille
213,94
with linear grille
309,59
without linear grille
210,79
with linear grille
319,42
LengthL
[mm]
Ribbedconvector length
Lribb. [mm]
∆T[K]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
1000 722504230
303233136
272,85 363,77400313190
365,70 461,35478372224
370,50 479,13
1250 972504230
408314183
312,05 425,70538421256
419,19 538,75643501301
423,20 558,99
1500 1222504230
513394230
351,25 487,63677530322
472,67 616,15809630378
475,90 638,84
1750 1472504230
618475277
390,45 549,56815638387
526,16 693,54974759456
528,59 718,70
2000 1722504230
723556325
429,65 611,49954747453
579,64 770,941140888533
581,29 798,55
2250 1972504230
828637372
468,85 673,421092855519
633,13 848,3413051017610
633,99 878,41
2500 2222504230
933717419
508,05 735,351231964585
686,61 925,7414711146688
686,69 958,26
2750 2472504230
1038798466
547,25 797,2813691072650
740,10 1003,1316361275765
739,38 1038,12
3000 2722504230
1143879513
586,45 859,2115081181716
793,58 1080,5318021404843
792,08 1117,97
3250 2890504230
1214933545
625,65 921,1416011254761
847,07 1157,9319131491895
844,78 1197,83
3500 3140504230
13191014592
664,85 983,0717401363827
900,55 1235,3320791620973
897,48 1277,68
3750 3390504230
14241095639
704,05 1045,0018781471892
954,04 1312,72224417491050
950,17 1357,54
4000 3640504230
15291175686
743,25 1106,9320171580958
1007,52 1390,12241018781127
1002,87 1437,39
4250 3890504230
16341256733
782,45 1168,86215516881024
1061,01 1467,52257520071205
1055,57 1517,25
4500 4140504230
17391337781
821,65 1230,79229417971090
1114,49 1544,92274121361282
1108,27 1597,10
4750 4390504230
18441418828
860,85 1292,72243219051155
1167,98 1622,31290622641359
1160,96 1676,96
5000 4640504230
19491498875
900,05 1354,65257120141221
1221,46 1699,71307223941437
1213,66 1756,81
14 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Asc
othe
rm e
co
KRP
91
LR: Aluminium linear grille, natural colour anodised (standard)
Ribbed convector length = length floor pan - 278 mm, for length > 3000 mm: length floor pan - 360 mm
Standard heat output at 75 / 65 / 20 °C (∆T 50K), Φ=ΦS
Ascotherm® eco KRP91Natural convection
Prices and heat outputs
Height 150 mm (depth 310–400 mm)
Version KRP91 KRP91 KRP91Depth T [mm] 310 360 400Exponent n [ ] 1,45 1,47 1,50Price per piece [EUR/pc.] 188,35 223,23 234,40
Price per metre [EUR/m]without linear
grille
220,22
with linear grille
352,47
without linear grille
265,20
with linear grille
411,62
without linear grille
273,74
with linear grille
431,08
LengthL
[mm]
Ribbedconvector length
Lribb. [mm]
∆T[K]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
1000 722504230
554433262
408,57 540,82620483290
488,43 634,85682529314
508,14 665,48
1250 972504230
746583353
463,63 628,94835651391
554,73 737,76919712423
576,58 773,25
1500 1222504230
937733443
518,68 717,061050818491
621,03 840,661155895532
645,01 881,02
1750 1472504230
1129883534
573,74 805,171264985591
687,33 943,5713911078641
713,45 988,79
2000 1722504230
13211033624
628,79 893,2914791152692
753,63 1046,4716271261749
781,88 1096,56
2250 1972504230
15131183715
683,85 981,4116941320792
819,93 1149,3818641445859
850,32 1204,33
2500 2222504230
17041332805
738,90 1069,5319091488893
886,23 1252,2821001628967
918,75 1312,10
2750 2472504230
18961482896
793,96 1157,6421231654993
952,53 1355,19233618111076
987,19 1419,87
3000 2722504230
20881633987
849,01 1245,76233818221094
1018,83 1458,09257219941185
1055,62 1527,64
3250 2890504230
221717331048
904,07 1333,88248319351161
1085,13 1561,00273121171258
1124,06 1635,41
3500 3140504230
240818831138
959,12 1422,00269721021262
1151,43 1663,90296723001367
1192,49 1743,18
3750 3390504230
260020331229
1014,18 1510,11291222691362
1217,73 1766,81320424841476
1260,93 1850,95
4000 3640504230
279221831320
1069,23 1598,23312724371463
1284,03 1869,71344026671584
1329,36 1958,72
4250 3890504230
298423331410
1124,29 1686,35334226041563
1350,33 1972,62367628501693
1397,80 2066,49
4500 4140504230
317524821501
1179,34 1774,47355627711663
1416,63 2075,52391230331802
1466,23 2174,26
4750 4390504230
336726331591
1234,40 1862,58377129381764
1482,93 2178,43414932171911
1534,67 2282,03
5000 4640504230
355927831682
1289,45 1950,70398631061865
1549,23 2281,33438534002020
1603,10 2389,80
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 15
Asc
othe
rm e
co
KRP
91
LR: Aluminium linear grille, natural colour anodised (standard)
Ribbed convector length = length floor pan - 278 mm, for length > 3000 mm: length floor pan - 360 mm
Standard heat output at 75 / 65 / 20 °C (∆T 50K), Φ=ΦS
Ascotherm® eco KRP91Natural convection
Prices and heat outputs
Height 200 mm (depth 185–260 mm)
Version KRP91 KRP91 KRP91Depth T [mm] 185 210 260Exponent n [ ] 1,52 1,45 1,46Price per piece [EUR/pc.] 116,05 151,34 163,35
Price per metre [EUR/m]without linear
grille
173,53
with linear grille
264,45
without linear grille
224,47
with linear grille
320,12
without linear grille
223,50
with linear grille
332,13
LengthL
[mm]
Ribbedconvector length
Lribb. [mm]
∆T[K]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
1000 722504230
367284167
289,58 380,50440344208
375,81 471,46523408246
386,85 495,48
1250 972504230
495382226
332,96 446,61593464280
431,93 551,49705550331
442,73 578,51
1500 1222504230
622481284
376,35 512,73745582352
488,05 631,52886692417
498,60 661,55
1750 1472504230
749579341
419,73 578,84898702424
544,16 711,551067833502
554,48 744,58
2000 1722504230
876677399
463,11 644,951050821496
600,28 791,581248974587
610,35 827,61
2250 1972504230
1004776458
506,49 711,061203941569
656,40 871,6114301116672
666,23 910,64
2500 2222504230
1131874516
549,88 777,1813551059640
712,52 951,6416111257757
722,10 993,68
2750 2472504230
1258972573
593,26 843,2915081179713
768,63 1031,6717921399843
777,98 1076,71
3000 2722504230
13851070631
636,64 909,4016601298785
824,75 1111,7019731540928
833,85 1159,74
3250 2890504230
14711137671
680,02 975,5117631378833
880,87 1191,7320951635985
889,73 1242,77
3500 3140504230
15981235728
723,41 1041,6319151497905
936,99 1271,76227717771071
945,60 1325,81
3750 3390504230
17261334787
766,79 1107,7420681617977
993,10 1351,79245819191156
1001,48 1408,84
4000 3640504230
18531432845
810,17 1173,85222017361049
1049,22 1431,82263920601241
1057,35 1491,87
4250 3890504230
19801530903
853,55 1239,96237318551122
1105,34 1511,85282022011326
1113,23 1574,90
4500 4140504230
21071628960
896,94 1306,08252519741193
1161,46 1591,88300223431412
1169,10 1657,94
4750 4390504230
223517271019
940,32 1372,19267820941266
1217,57 1671,91318324841497
1224,98 1740,97
5000 4640504230
236218251077
983,70 1438,30283022131338
1273,69 1751,94336426261582
1280,85 1824,00
16 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Asc
othe
rm e
co
KRP
91
LR: Aluminium linear grille, natural colour anodised (standard)
Ribbed convector length = length floor pan - 278 mm, for length > 3000 mm: length floor pan - 360 mm
Standard heat output at 75 / 65 / 20 °C (∆T 50K), Φ=ΦS
Ascotherm® eco KRP91Natural convection
Prices and heat outputs
Height 200 mm (depth 310–400 mm)
Version KRP91 KRP91 KRP91Depth T [mm] 310 360 400Exponent n [ ] 1,46 1,46 1,48Price per piece [EUR/pc.] 190,57 223,23 234,40
Price per metre [EUR/m]without linear
grille
230,37
with linear grille
362,62
without linear grille
278,27
with linear grille
424,69
without linear grille
286,81
with linear grille
444,15
LengthL
[mm]
Ribbedconvector length
Lribb. [mm]
∆T[K]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
Φ[watts]
Price [EUR]
Price [EUR]
1000 722504230
630492296
420,94 553,19814635383
501,50 647,92944734439
521,21 678,55
1250 972504230
848662399
478,53 643,851096855515
571,07 754,091270988591
592,91 789,59
1500 1222504230
1066832501
536,13 734,5013781076648
640,64 860,2715971242743
664,62 900,63
1750 1472504230
12841002604
593,72 825,1616601296781
710,20 966,4419241497895
736,32 1011,66
2000 1722504230
15021172706
651,31 915,8119421516913
779,77 1072,61225117511048
808,02 1122,70
2250 1972504230
17201343809
708,90 1006,47222417361046
849,34 1178,78257720051199
879,72 1233,74
2500 2222504230
19381513911
766,50 1097,12250619561178
918,91 1284,96290422591351
951,43 1344,78
2750 2472504230
215616831014
824,09 1187,78278821761311
988,47 1391,13323125131504
1023,13 1455,81
3000 2722504230
237418531116
881,68 1278,43307023961444
1058,04 1497,30355827681656
1094,83 1566,85
3250 2890504230
252019671185
939,27 1369,09326025451533
1127,61 1603,47377729381758
1166,53 1677,89
3500 3140504230
273821371287
996,87 1459,74354227651665
1197,18 1709,65410431931910
1238,24 1788,93
3750 3390504230
295623071390
1054,46 1550,40382429851798
1266,74 1815,82443134472062
1309,94 1899,96
4000 3640504230
317424771492
1112,05 1641,05410632051931
1336,31 1921,99475737012214
1381,64 2011,00
4250 3890504230
339226481595
1169,64 1731,71438834252063
1405,88 2028,16508439552366
1453,34 2122,04
4500 4140504230
361028181697
1227,24 1822,36467036452196
1475,45 2134,34541142092518
1525,05 2233,08
4750 4390504230
382829881800
1284,83 1913,02495238652328
1545,01 2240,51573844642670
1596,75 2344,11
5000 4640504230
404631581902
1342,42 2003,67523440852461
1614,58 2346,68606447172822
1668,45 2455,15
Ascotherm® ecoProduct details
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 65
Prod
uct
deta
ils
The new connection sets with factory preset kV valves
Control curves for valve inserts
Standard valve insert V5K S
Presetting 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,56 8
kvs value up to 0,16 0,21 0,24 0,30 0,34 0,41 0,44 0,54 0,65 0,82 0,98 1,11 1,23 1,33 1,43
Pres
sure
loss
in m
bar
321 4 5 6
87
1,5 2,5 3,5 4,5 5,5
7,56,5
100
1000
10 1002 3 4 5 6 7 8 9 2 3 4 5 6 7 8 9
1000
10
2
345
6 78 9
2
345
6 78 9
Water flow in kg/h
Connection sets for the Ascotherm ecoIt is recommended that the Ascotherm eco be fitted with preset kv connection sets (see accessories range). On request, the instal-lation can be done at the factory.
The Ascotherm eco units are fitted with preset connection sets depending on the heating or cooling capacity.
Ascotherm eco units can also be fitted with the fine-adjusting valve. The adjustable valve insert permits reproducible settings of low water flow rates. The setting values can be taken from the diagram.
Ascotherm® ecoProduct details
66 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Prod
uct
deta
ils
The new connection sets with factory preset kV valves
Valve performance limits of valve inserts for the Ascotherm eco connection setsPlease note the valve performance limits in relation to the system parameters
Standard valve insert V5K S
Presetting kvs value Δp [mbar]
Temperature difference ΔT [K]
2 4 6 8 10 12 15 20
1 0,16
60 92 183 275 366 458 549 686 91580 106 211 317 423 528 634 793 1057
100 118 236 354 473 591 709 886 1182120 129 259 388 518 647 777 971 1294140 140 280 419 559 699 839 1049 1398
1,5 0,21
60 120 240 360 480 601 721 901 120180 139 277 416 555 694 832 1040 1387
100 155 310 465 620 775 930 1163 1551120 170 340 510 680 849 1019 1274 1699140 183 367 550 734 917 1101 1376 1835
2 0,24
60 137 275 412 549 686 824 1030 137380 159 317 476 634 793 951 1189 1585
100 177 354 532 709 886 1063 1329 1772120 194 388 582 777 971 1165 1456 1941140 210 419 629 839 1049 1258 1573 2097
2,5 0,30
60 169 337 506 675 844 1012 1266 168780 195 390 585 779 974 1169 1461 1948
100 218 436 654 871 1089 1307 1634 2178120 239 477 716 955 1193 1432 1790 2386140 258 516 773 1031 1289 1547 1933 2578
3 0,34
60 194 389 583 778 972 1167 1459 194580 225 449 674 898 1123 1347 1684 2246
100 251 502 753 1004 1255 1506 1883 2511120 275 550 825 1100 1375 1650 2063 2750140 297 594 891 1188 1485 1782 2228 2971
3,5 0,41
60 235 469 704 938 1173 1407 1759 234580 271 542 812 1083 1354 1625 2031 2708
100 303 606 908 1211 1514 1817 2271 3028120 332 663 995 1327 1658 1990 2487 3317140 358 716 1075 1433 1791 2149 2687 3582
4 0,44
60 252 503 755 1007 1258 1510 1888 251780 291 581 872 1162 1453 1744 2180 2906
100 325 650 975 1300 1625 1950 2437 3249120 356 712 1068 1424 1780 2136 2669 3559140 384 769 1153 1538 1922 2307 2883 3845
4,5 0,54
60 309 618 927 1236 1544 1853 2317 308980 357 713 1070 1427 1783 2140 2675 3567
100 399 798 1196 1595 1994 2393 2991 3988120 437 874 1310 1747 2184 2621 3276 4368140 472 944 1415 1887 2359 2831 3539 4718
5 0,65
60 372 744 1115 1487 1859 2231 2789 371880 429 859 1288 1717 2147 2576 3220 4293
100 480 960 1440 1920 2400 2880 3600 4800120 526 1052 1577 2103 2629 3155 3944 5258140 568 1136 1704 2272 2840 3408 4260 5679
5,5 0,82
60 469 938 1407 1876 2345 2814 3518 469080 542 1083 1625 2166 2708 3250 4062 5416
100 606 1211 1817 2422 3028 3633 4541 6055120 663 1327 1990 2653 3317 3980 4975 6633140 716 1433 2149 2866 3582 4299 5374 7165
6 0,98
60 561 1121 1682 2242 2803 3363 4204 560680 647 1295 1942 2589 3236 3884 4855 6473
100 724 1447 2171 2895 3618 4342 5428 7237120 793 1586 2378 3171 3964 4757 5946 7928140 856 1713 2569 3425 4281 5138 6422 8563
6,5 1,11
60 635 1270 1905 2540 3175 3810 4762 634980 733 1466 2199 2933 3666 4399 5499 7331
100 820 1639 2459 3279 4098 4918 6148 8197120 898 1796 2694 3592 4490 5388 6734 8979140 970 1940 2910 3879 4849 5819 7274 9699
7 1,23
60 704 1407 2111 2814 3518 4221 5277 703680 812 1625 2437 3250 4062 4874 6093 8124
100 908 1817 2725 3633 4541 5450 6812 9083120 995 1990 2985 3980 4975 5970 7462 9950140 1075 2149 3224 4299 5374 6448 8060 10747
7,5 1,33
60 761 1522 2282 3043 3804 4565 5706 760880 878 1757 2635 3514 4392 5271 6588 8785
100 982 1964 2946 3929 4911 5893 7366 9821120 1076 2152 3228 4304 5379 6455 8069 10759140 1162 2324 3486 4648 5810 6973 8716 11621
8 1,43
60 818 1636 2454 3272 4090 4908 6135 818080 945 1889 2834 3778 4723 5667 7084 9445
100 1056 2112 3168 4224 5280 6336 7920 10560120 1157 2314 3470 4627 5784 6941 8676 11568140 1249 2499 3748 4998 6247 7497 9371 12495
Ascotherm® ecoProduct details
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 67
Prod
uct
deta
ils
The new connection sets with factory preset kV valves
Fine-adjusting valve insert V5K F
Presetting 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,56 8
kvs value up to 0,06 0,06 0,07 0,07 0,08 0,09 0,1 0,11 0,12 0,15 0,17 0,21 0,25 0,37 0,5
Pres
sure
loss
in m
bar
22,5
11,5
3 4 5 6 7 83,5 4,5 5,5 6,5 7,5
100
1000
10 1002 3 4 5 6 7 8 9 2 3 4 5 6 7 8 9
1000
10
2
345
6 78 9
2
345
6 78 9
Water flow in kg/h
Ascotherm® ecoProduct details
68 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Prod
uct
deta
ils
The new connection sets with factory preset kV valves
Valve performance limits of valve inserts for the Ascotherm eco connection setsPlease note the valve performance limits in relation to the system parameters
Fine-adjusting valve insert V5K F
Presetting kvs value Δp [mbar]
Temperature difference ΔT [K]
2 4 6 8 10 12 15 20
1 0,06
60 34 69 103 137 172 206 257 34380 40 79 119 159 198 238 297 396
100 44 89 133 177 222 266 332 443120 49 97 146 194 243 291 364 485140 52 105 157 210 262 315 393 524
1,5 0,06
60 34 69 103 137 172 206 257 34380 40 79 119 159 198 238 297 396
100 44 89 133 177 222 266 332 443120 49 97 146 194 243 291 364 485140 52 105 157 210 262 315 393 524
2 0,07
60 40 80 120 160 200 240 300 40080 46 92 139 185 231 277 347 462
100 52 103 155 207 258 310 388 517120 57 113 170 227 283 340 425 566140 61 122 183 245 306 367 459 612
2,5 0,07
60 40 80 120 160 200 240 300 40080 46 92 139 185 231 277 347 462
100 52 103 155 207 258 310 388 517120 57 113 170 227 283 340 425 566140 61 122 183 245 306 367 459 612
3 0,08
60 46 92 137 183 229 275 343 45880 53 106 159 211 264 317 396 528
100 59 118 177 236 295 354 443 591120 65 129 194 259 324 388 485 647140 70 140 210 280 350 419 524 699
3,5 0,09
60 51 103 154 206 257 309 386 51580 59 119 178 238 297 357 446 594
100 66 133 199 266 332 399 498 665120 73 146 218 291 364 437 546 728140 79 157 236 315 393 472 590 786
4 0,10
60 57 114 172 229 286 343 429 57280 66 132 198 264 330 396 495 660
100 74 148 222 295 369 443 554 738120 81 162 243 324 404 485 607 809140 87 175 262 350 437 524 655 874
4,5 0,11
60 63 126 189 252 315 378 472 62980 73 145 218 291 363 436 545 727
100 81 162 244 325 406 487 609 812120 89 178 267 356 445 534 667 890140 96 192 288 384 481 577 721 961
5 0,12
60 69 137 206 275 343 412 515 68680 79 159 238 317 396 476 594 793
100 89 177 266 354 443 532 665 886120 97 194 291 388 485 582 728 971140 105 210 315 419 524 629 786 1049
5,5 0,15
60 86 172 257 343 429 515 644 85880 99 198 297 396 495 594 743 991
100 111 222 332 443 554 665 831 1108120 121 243 364 485 607 728 910 1213140 131 262 393 524 655 786 983 1311
6 0,17
60 97 194 292 389 486 583 729 97280 112 225 337 449 561 674 842 1123
100 126 251 377 502 628 753 942 1255120 138 275 413 550 688 825 1031 1375140 149 297 446 594 743 891 1114 1485
6,5 0,21
60 120 240 360 480 601 721 901 120180 139 277 416 555 694 832 1040 1387
100 155 310 465 620 775 930 1163 1551120 170 340 510 680 849 1019 1274 1699140 183 367 550 734 917 1101 1376 1835
7 0,25
60 143 286 429 572 715 858 1073 143080 165 330 495 660 826 991 1238 1651
100 185 369 554 738 923 1108 1385 1846120 202 404 607 809 1011 1213 1517 2022140 218 437 655 874 1092 1311 1638 2184
7,5 0,37
60 212 423 635 847 1058 1270 1587 211680 244 489 733 978 1222 1466 1833 2444
100 273 546 820 1093 1366 1639 2049 2732120 299 599 898 1197 1497 1796 2245 2993140 323 647 970 1293 1616 1940 2425 3233
8 0,50
60 286 572 858 1144 1430 1716 2145 286080 330 660 991 1321 1651 1981 2477 3302
100 369 738 1108 1477 1846 2215 2769 3692120 404 809 1213 1618 2022 2427 3034 4045140 437 874 1311 1748 2184 2621 3277 4369
Ascotherm® ecoProduct details
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 69
Prod
uct
deta
ils
The new connection sets with factory preset kV valves
Factory kV presetting of the valves
KRP91
H [mm] 92 120 150 200
T [mm] 185 210 260 310 360 400 185 210 260 310 360 400 185 210 260 310 360 400 185 210 260 310 360 400
L [mm] Preset kV values
1000 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5*
1250 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 2,5 2,5
1500 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5 5,5* 5,5* 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5
1750 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5 5,5* 5,5* 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5
2000 5,5* 5,5* 5,5* 5,5* 5,5* 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 4,5
2250 5,5* 5,5* 5,5* 5,5* 5,5* 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 4,5 4,5
2500 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 4,5 4,5
2750 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5
3000 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5
3250 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 2,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5
3500 5,5* 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 6,0
3750 5,5* 2,5 2,5 2,5 2,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 6,0
4000 2,5 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 6,0 6,0
4250 2,5 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 6,0 6,0
4500 2,5 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 4,5 6,0 2,5 4,5 4,5 4,5 6,0 6,0
4750 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 4,5 6,0 4,5 4,5 4,5 4,5 6,0 6,0
5000 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 6,0 6,0 4,5 4,5 4,5 6,0 6,0 6,0
* Fine-adjusting valve
Dimensioning:
Heat outputs at 70 / 55 / 20°C,
Pressure loss across the valve 100 mbar
Ascotherm® ecoProduct details
70 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Prod
uct
deta
ils
The new connection sets with factory preset kV valves
Factory kV presetting of the valves
KRN92
H [mm] 110 150 200
T [mm] 185 210 260 310 360 400 185 210 260 310 360 400 185 210 260 310 360 400
L [mm] Preset kV values
1000 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5*
1250 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5*
1500 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5*
1750 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 2,5 2,5
2000 5,5* 5,5* 5,5* 5,5 5,5 5,5 5,5* 5,5* 5,5* 5,5* 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5
2250 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5
2500 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5
2750 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5
3000 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5
3250 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 4,5 4,5
3500 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 4,5 5,5* 5,5* 2,5 2,5 4,5 4,5
3750 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5
4000 5,5* 5,5* 2,5 2,5 2,5 4,5 5,5* 5,5* 2,5 2,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5
4250 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5
4500 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 2,5 2,5 4,5 4,5 4,5
4750 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5
5000 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5
* Fine-adjusting valve
Dimensioning:
Heat outputs at 70 / 55 / 20°C,
Pressure loss across the valve 100 mbar
Ascotherm® ecoProduct details
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 71
Prod
uct
deta
ils
The new connection sets with factory preset kV valves
Factory kV presetting of the valves
KRN81
H [mm] 110
T [mm] 185 210 260 310 360
L [mm] Preset kV values
1250 2,5 2,5 2,5 2,5 4,5
1500 2,5 2,5 2,5 2,5 4,5
1750 2,5 2,5 4,5 4,5 4,5
2000 4,5 4,5 4,5 4,5 6
2250 4,5 4,5 4,5 4,5 6
2500 4,5 4,5 6 6 6
2750 4,5 6 6 6 6
3000 4,5 6 6 6 6
3250 4,5 6 6 6 6
3500 6 6 6 6 8
3750 6 6 6 6 8
4000 6 6 6 8 8
Dimensioning:
Heat outputs at 70 / 55 / 20°C,
Pressure loss across the valve 100 mbar
Ascotherm® ecoProduct details
72 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Prod
uct
deta
ils
The new connection sets with factory preset kV valves
Factory kV presetting of the valves
KC 281
H [mm] 130 155
T [mm] 310 360 310 360
L [mm] Preset kV values
1250 6 6 6 8
2000 0* 0* 0* 0*
2750 0* 0* 0* 0*
Note:
On the KC2 81, the valve inserts are preset in relation to the cooling capacity, since the water flow rate required for cooling is usually higher than for heating.
Dimensioning:
Cooling capacities at 16 / 18 / 27°C,
Pressure loss across the valve 100 mbar
KC 481
H [mm] 130 155
T [mm] 330 360 330 360
L [mm] Preset kV values
1250 6 6 6 6
2000 0* 0* 0* 0*
2750 0* 0* 0* 0*
Dimensioning:
Cooling capacities at 16 / 18 / 27°C,
Pressure loss across the valve 100 mbar
KC 481
H [mm] 130 155
T [mm] 330 360 330 360
L [mm] Preset kV values
1250 4,5 4,5 4,5 4,5
2000 6 8 6 8
2750 8 0* 8 0*
Dimensioning:
Heat outputs at 70 / 55 / 20°C,
Pressure loss across the valve 100 mbar
* Wherever kv preset values are stated as 0, the maximum convector outputs are above the valve performance limits for the indicated system parameters. In this case, it is necessary to check whether the dimensioned output is within the valve performance limits. See data under valve performance limits.
Ascotherm® ecoArbonia Individual
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 73
Asc
othe
rm e
co
Indi
vidu
al
Special versions
Angled version
• Available for all versions and for empty pan• Angle can be between 50° and 320° Please provide a dimensional drawing or template with the
order.• Feasibility depends on engineering review• Radiator must still be transportable
Dimensional drawing
Orde-ring code |BES|
Additional price / bevel cut
[EUR]
Floor pan
Linear grille
Roll-up grille
Single bevel
90°
L2
L1
TWA
W A T
L1
L2
270°
76
771)49,00 46,00 164,00
WA
T
L1
L2
αL1
L2
α
WA
T
1) Characteristic 77 for bevel cut at both ends
L1, L2: Length of the limbs, measured on the wallα: AngleT: Depth floor panWA: Wall spacing
Ascotherm® ecoArbonia Individual
74 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Asc
othe
rm e
co
Indi
vidu
al
Special versions
Curved version
• Available for KRP91 (other versions on request)• Bending radius R: at least 1000 mm Please provide a dimensional drawing or template with the
order.• Feasibility depends on engineering review• Radiator must still be transportable
Dimensional drawing
Orde-ring code |BES|
Additional price per radiator
[EUR]
L
R T
W A
Inside radius
70 On requestW A
T
R
L
Outside radius
L: Streched lengthR: Bending radius (wall radius)T: Depth floor panWA: Wall spacing
Ascotherm® ecoArbonia Individual
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 75
Asc
othe
rm e
co
Indi
vidu
al
Special versions
Column section version
• Available for all versions and for empty pan Please provide a dimensional drawing or template with the
order.• Feasibility depends on engineering review• Radiator must still be transportable
Dimensional drawing
Orde-ring codeIBESI
Additional price per column section
[EUR]
Floor pan
Linear grille
Roll-up grille
Column section according to drawing
75On
requestOn
requestOn
request
column section in floor pan column section in linear grille column section in roll-up grille
A
Ød C
A
Ød C
A
Ød C
A B
C
A B
C
A B
C
d: DiameterA: Inset dimension for lengthB: Edge dimensionC: Inset dimension for depth
Ascotherm® ecoArbonia Individual
76 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Asc
othe
rm e
co
Indi
vidu
al
Special versions
Version with impact sound insulation
Description
Orde-ring codeIEBTI
Additional price per
metre [EUR]
Without impact sound insulation
• Standard version wit-hout
–
With impact sound insulation
TS1 39,00
Coupled Ascotherm• radiators are supplied individually• Connection material (flexible connection hoses etc. available as accessory)• Only for versions KRP91 (not for H 150 and H 200), KRN92, KRN81• On version KRN81 (max. up to 4 motors)
Con-nection system Description
Sequence of coupled radiatorsΔ(enter in column "Special characteri-stics")
Ordering code|KHP|
Additio-nal price per radi-
ator [EUR]
Connec-tion on the same side from the left
• Radiator position 2 re-peats when coupling more than 3 radiators
• Please provide a draw-ing with the order
Initial radiator1
Middle radiator2
Final radiator3
75 67,00Connec-tion on the same side from the right
• Radiator position 2 re-peats when coupling more than 3 radiators
• Please provide a draw-ing with the order
Final radiator3
Middle radiator2
Initial radiator1
Impact sound insulation 4 mm
Ascotherm® ecoArbonia Individual
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 77
Asc
othe
rm e
co
Indi
vidu
al
Special versions
Air connection with air connection valve
Number of air connec-tions|LAZ| Length [mm] Description and dimensional drawings
Air connection arrangement
|LAP|1)
Height H
[mm]
Connec-tion size
|LAG|
Additional price per
additional connec-
tion [EUR]
1 ≤ 3000 mm • Standard: 1 air connection, incl. air valve • Additional air connections possible (max.
number and location on request) • Air connections are distributed evenly (to the
extent technically possible)• The exact positioning of the air connections
can be seen in the drawing
– 110, 150, 200 63 39,00
150, 200 80 41,00
200 100 44,00
200 125 46,00
2 > 3000 mm • Standard: 2 air connections, incl. air valves • Additional air connections possible (max.
number and location on request) • Air connections are distributed evenly (to the
extent technically possible)• The exact positioning of the air connections
can be seen in the drawing
• No clear assignment of positions, since floor pan joined at the factory
110, 150, 200 63 39,00
150, 200 80 41,00
200 100 44,00
200 125 46,00
Special connections - Version per drawing - Ordering code LAP = SON On re-quest
1) The positioning of the air connections is affected slightly by the arrangement of the cross bracing in the floor pan, example: connec-tion F (room side, centred) = "approx. centred" The exact dimensions/positions can be seen in the drawing and need to be approved by the customer.
Number and positions of the air connections
L/2 ±75L/2 ±75L ≤ 3000
L/4 ±150 L/4 ±150L > 3000
Ascotherm® ecoArbonia Individual
78 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Asc
othe
rm e
co
Indi
vidu
al
Special versions
Additional special versions
Description
Cha-racteri-
stic
Orde-ring code
Additional price per radiator
[EUR]
Pressure version High-pressure version16 bar (1600 kPa) |DRU| 16 + 5 %
Special versions Special length for heating 1)
• > 1000 mm (KRP91 and KRN92)• > 1250 mm possible (KRN81)
|BES| SBL Next-larger standard length
Special length for heating and cooling 1)
• > 1250 mm possible |BES| SBL On request
Extra-short length (smaller than smallest standard length)
• 600 mm - < 1000 mm possible (KRP91 and KRN92)• 1000 mm - < 1250 possible (KRN81)• 850 mm - < 1250 mm possible (KC281)• 1050 mm - < 1250 mm possible (KC481)
|BES| SBL On request
Special depth acc. to drawing 2) |BES| SBT On request
Special height according to drawing 3) |BES| SBH On request
Fixing Fixing with special bracket (in case of high soil structure) On request
Special finish Finished in special colour (no RAL colour)
Aluminium linear grille / aluminium roll-up grille |AUS| SF On request
Floor pan and register |FAR1| 99 On request
Finished in other RAL colour (standard is RAL 7016)
Floor pan and register |FAR1| SF + 30 %
1) Provide exact length2) Provide exact depth3) Provide exact height
Ascotherm® ecoAscotherm® eco Individual
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 79
Asc
othe
rm e
co
Indi
vidu
al
On request, accessory components, available factory-installed
Available on request
Description
Cha-racteri-
stic
Orde-ring code
Additional price per
metre [EUR]
Edge bar
Anodised in natural colour ELO = Anodised in natural colour |RDL| ELO –
Colour anodised BRO = Anodised in bronze finish MES = Anodised in brass finish DKS = Anodised in dark silver finish SWZ = Anodised in black finish EDS = Anodised in stainless steel finish
|RDL| BROMESDKSSWZEDS
11,0011,0011,0011,0011,00
Paint finish FAR1 = Edge bar finished as floor pan/register |RDL| FAR1 –
FAR2 = Edge bar finished as top grille |RDL| FAR2 49,00
Air-intake filter • For KRN81 air-intake filter PPI 30 dark 90 x 3 mm |FVL| FV 8,00
• For KC281 and KC481 air -ntake filter PPI 30 dark 140 x 3 mm |FVL| FV 9,00
Accessory components, factory-installed
Description
Cha-racteri-
stic
Orde-ring code
Additional price per radiator
[EUR]
Installation Connection set, straight form with pre-set kv valve
Consisting of:
• Valve base with factory preset kv valve– DN 15, both sides 3/4“ external thread
with euro taper– M30 x 1,5– nickel-plated, protective cap
• Return fitting with shut-off– DN 15, both sides 3/4“ external thread
with euro taper– nickel-plated
• Threaded fitting attached only hand-tight
• For all KRN, KRP91 and KC281 with connection 11 or 33
|VRS| VRS 44,00
• For KC481 with connec-tion 11 or 33
|VRS| VRS 88,00
Connection set, angled version with preset kv valve
Consisting of:
• Valve base with factory preset kv valve– DN 15, both sides 3/4“ external thread
with euro taper– M30 x 1,5– nickel-plated, protective cap
• Return fitting with shut-off– DN 15, both sides 3/4“ external thread
with euro taper– nickel-plated
• Threaded fitting attached only hand-tight
• For KC281 with connec-tion BB or DD
|VRS| VRS 44,00
• For KC481 with connec-tion BB or DD
|VRS| VRS 88,00
Connection set, angled version with preset kv val-ve, connection arrangement 66/88
Consisting of:
• Valve base with factory preset kv valve– DN 15, outlet 3/4“ external thread with
euro taper, inlet 1/2“ internal thread– M30 x 1,5– nickel-plated, protective cap
• Return fitting with shut-off– DN 15, both sides 3/4“ external thread
with euro taper– nickel-plated
• Threaded fitting attached only hand-tight
• For KRP91, KRN92 and KRN81
|VRS| VRS 44,00
Thermoelec-tric actuator 230 V AC
• Factory-installed • Only in conjunction with VRS
• For KRP91 and KRN92
|STT| STT 29,00
Thermoelec-tric actuator 24 V DC
• Factory-installed and with controller board wired
• Only in conjunction with VRS
• For KRN81 and KC281
|STT| STT 92,00
• For KC481 |STT| STT 184,00
KNX plug-in card (for KRN81, KC281 and KC481)
• for installation in the Ascotherm eco control board to connect to KNX networks, only 1 per convector group is needed (up to 6 convectors)
• For KRN81, KC281 and KC481
|GLT| KNX 146,00
Ascotherm® ecoAccessories
80 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Acc
esso
ries
Empty floor pan
1) Dimensions |HOE| and |MT| need to be stated with the order (for description, see chapter "General information")
Prices for other colours, see chapter "Ascotherm top grilles" and "Special versions".
Ascotherm eco empty floor panFor the ... Arbonia offers an Ascotherm empty floor pan in its accessories range.
The range available (H / B / T) and the special or extra-short empty floor pan lengths are listed at the individual versions.
Description Product code Characteristic
Dimensi-ons
Ordering code
ProductVersion
Ordering code
|3|
Priceper
piece[EUR/pc.]
Priceper
metrewithout grille
[EUR/m]
Priceper
metrewith grille[EUR/m]
Priceper
metrewithout grille
[EUR/m]|3.1| |3.4|
Empty floor panZA0108
Dimensions
• Heights:– 92, 110, 120, 130,
150, 155, 200 mm• Depths:
– 185, 210, 260, 310, 330, 360, 400 mm
• Lengths variable:– 200–3000 mm
Finish
• Standard in anthraci-te grey (RAL 7016 matt finish)
Top grille version
• Standard in alumi-nium, anodised in natural colour
Material
• Galvanised sheet steel, colour-coated
92 185 ZA0108 1)
111,30 89,04 179,96 179,96
210 111,30 100,17 195,82 195,82
260 111,30 111,30 219,93 219,93
310 111,30 122,43 254,68 254,68
360 111,30 133,56 279,98 279,98
400 111,30 144,69 302,03 302,03
110 185 ZA0108 1)
111,30 100,17 191,09 191,09
210 111,30 111,30 206,95 206,95
260 111,30 122,43 231,06 231,06
310 111,30 133,56 265,81 265,81
360 111,30 144,69 291,11 291,11
400 111,30 155,82 313,16 313,16
120 185 ZA0108 1) 111,30 100,17 271,38 271,38
210 111,30 111,30 282,62 282,62
260 111,30 122,43 296,68 296,68
310 111,30 133,56 191,09 191,09
360 111,30 144,69 206,95 206,95
400 111,30 155,82 231,06 231,06
130 310 ZA0108 1) 111,30 139,13 265,81 265,81
330 111,30 144,70 291,11 291,11
360 111,30 150,26 313,16 313,16
150 185 ZA0108 1)
111,30 111,30 202,22 202,22
210 111,30 122,43 218,08 218,08
260 111,30 133,56 242,19 242,19
310 111,30 144,69 276,94 276,94
360 111,30 155,82 302,24 302,24
400 111,30 166,95 324,29 324,29
155 310 ZA0108 1)
111,30 150,26 282,51 282,51
330 111,30 155,83 293,75 293,75
360 111,30 161,40 307,82 307,82
200 185 ZA0108 1)
111,30 122,43 213,35 213,35
210 111,30 133,56 229,21 229,21
260 111,30 144,69 253,32 253,32
310 111,30 155,82 288,07 288,07
360 111,30 166,95 313,37 313,37
400 111,30 178,08 335,42 335,42
Ascotherm® eco Accessories
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 81
Acc
esso
ries
1) Dimensions characteristic |MT| and ordering code need to be stated when ordering (for description, see chapter "General informati-on" and colour chart)
Top grilles
are attractively shaped, solid and robust. There are practically no limits to how they can be integrated into the architectural design of the room, thanks to the choice of various profile forms,
materials and
Surface finishes. The grilles can easily be removed for cleaning and then returned to their original positions.
Ascotherm eco top grilles
Description Product code Characteristic
Dimen-sions
Ordering code|MT|
Version
ProductVersion
Price per
metre [EUR/m]]Description
Orde-ring code
Alumini-um linear grille
ZA0109
Dimensions• Length up to 5000 mm
– up to 3000 mm in one piece
– as of 3001 mm in two pieces
• Height 20 mm• Bar width 6 mm• Bar spacing 10 mm• Open cross-section 60 %
Finish
• Anodised in natural or co-lour, powder-coated in RAL colours
• Anodised colours– Natural (ELO)– Bronze (BRO)– Dark silver (DKS)– Brass (MES)– Black (SWZ)
• Cut surfaces in aluminium colour if linear grille is in two pieces
Version
• Longitudinal profile bars are fixedly connected to aluminium angle profiles by means of a pressure process every 200-300 mm
Material
• Aluminium profiles
T = 185 Natural anodised ELO ZA0109 1) 90,92
Colour anodised BROMESDKSSWZ
ZA0109 1) 161,76
Finished in colour of choice
LAC ZA0109 1) 118,20
T = 210 Natural anodised ELO ZA0109 1) 95,65
Colour anodised BROMESDKSSWZ
ZA0109 1) 166,50
Finished in colour of choice
LAC ZA0109 1) 124,33
T = 260 Natural anodised ELO ZA0109 1) 108,63
Colour anodised BROMESDKSSWZ
ZA0109 1) 179,49
Finished in colour of choice
LAC ZA0109 1) 141,22
T = 310 Natural anodised ELO ZA0109 1) 132,25
Colour anodised BROMESDKSSWZ
ZA0109 1) 203,10
Finished in colour of choice
LAC ZA0109 1) 171,93
T = 330 Natural anodised ELO ZA0109 1) 137,92
Colour anodised BROMESDKSSWZ
ZA0109 1) 208,77
Finished in colour of choice
LAC ZA0109 1) 179,30
T = 360 Natural anodised ELO ZA0109 1) 146,42
Colour anodised BROMESDKSSWZ
ZA0109 1) 217,28
Finished in colour of choice
LAC ZA0109 1) 190,35
T = 400 Natural anodised ELO ZA0109 1) 157,34
Colour anodised BROMESDKSSWZ
ZA0109 1) 228,62
Finished in colour of choice
LAC ZA0109 1) 205,09
Natural anodised
Bronze
Dark silver
Brass
black
Ascotherm® ecoAccessories
82 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Acc
esso
ries
1) Dimensions characteristic |MT| and ordering code need to be stated when ordering (for description, see chapter "General informati-on" and colour chart)
Top grilles
Ascotherm eco top grilles
Description Product code Characteristic
Dimen-sions
Ordering code|MT|
Version
ProductVersion
Price per
metre [EUR/m]Description
Orde-ring code
Flexible aluminium roll-up grille
ZA0110
Dimensions• Length up to 5000 mm
– up to 3000 mm in one piece
– as of 3001 mm in two pieces
• Height 20 mm• Bar width 6 mm• Bar spacing 14 mm
– other spacings on request• Open cross-section 70 %
Finish
• Anodised in natural or co-lour, powder-coated in RAL colours
• Anodised colours– Natural (ELO)– Bronze (BRO)– Dark silver (DKS)– Brass (MES)– Black (SWZ)
• Cut surfaces in aluminium colour if linear grille is in two pieces
Version
• Anodised in natural colour– Cross connections with
chrome steel springs and PVC spacers in grey
• Anodised in colour– Cross connections with
chrome steel springs and PVC spacers in black
• Finished in colour of choice– Cross connections with
chrome steel springs and PVC spacers in black
Material
• Aluminium profiles
T = 185 Natural anodised ELO ZA0110 1) 90,92
Colour anodised BROMESDKSSWZ
ZA0110 1) 161,76
Finished in colour of choice
LAC ZA0110 1) 118,20
T = 210 Natural anodised ELO ZA0110 1) 95,65
Colour anodised BROMESDKSSWZ
ZA0110 1) 166,50
Finished in colour of choice
LAC ZA0110 1) 124,33
T = 260 Natural anodised ELO ZA0110 1) 108,63
Colour anodised BROMESDKSSWZ
ZA0110 1) 179,49
Finished in colour of choice
LAC ZA0110 1) 141,22
T = 310 Natural anodised ELO ZA0110 1) 132,25
Colour anodised BROMESDKSSWZ
ZA0110 1) 203,10
Finished in colour of choice
LAC ZA0110 1) 171,93
T = 330 Natural anodised ELO ZA0110 1) 137,92
Colour anodised BROMESDKSSWZ
ZA0110 1) 208,77
Finished in colour of choice
LAC ZA0110 1) 179,30
T = 360 Natural anodised ELO ZA0110 1) 146,42
Colour anodised BROMESDKSSWZ
ZA0110 1) 217,28
Finished in colour of choice
LAC ZA0110 1) 190,35
T = 400 Natural anodised ELO ZA0110 1) 157,34
Colour anodised BROMESDKSSWZ
ZA0110 1) 228,62
Finished in colour of choice
LAC ZA0110 1) 205,09
Natural anodised
Brass
Dark silver
black
Bronze
Ascotherm® eco Accessories
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 83
Acc
esso
ries
1) Dimensions characteristic |MT| and ordering code need to be stated when ordering (for description, see chapter "General informati-on" and colour chart)
Top grilles
Ascotherm eco top grilles
Description Product code Characteristic
Dimen-sions
Ordering code|MT|
Version
ProductVersion
Price per
metre [EUR/m]]Description
Orde-ring code
Stainless steel roll-up grille
ZA0111
Dimensions• Length up to 5000 mm
– up to 3000 mm in one piece
– as of 3001 mm in two pieces
• Height 20 mm• Profile width 10 mm• Profile spacing 16 mm• Open cross-section 60 %
Version
• Cross connections with chrome steel springs and PVC spacers in grey
• Aluminium edge bar in stain-less steel optic
Material
• Stainless steel• Not to be used at tempe-
ratures below dew point (danger of slipping)
T = 185 Stainless steel EDS ZA0111 1) 413,29
T = 210 Stainless steel EDS ZA0111 1) 448,70
T = 260 Stainless steel EDS ZA0111 1) 495,94
T = 310 Stainless steel EDS ZA0111 1) 543,17
T = 330 Stainless steel EDS ZA0111 1) 562,06
T = 360 Stainless steel EDS ZA0111 1) 590,40
T = 400 Stainless steel EDS ZA0111 1) 628,18
Wooden roll-up grille
ZA0112
Dimensions• Length up to 5000 mm
– up to 3000 mm in one piece
– as of 3001 mm in two pieces
• Height 20 mm• Profile width 12 mm• Profile spacing 16 mm• Open cross-section 55 %
Version
• Light oak, ash and beech, oiled
• Aluminium edge bar, natural
Material
• Cross connections with chrome steel springs and PVC spacers in white
• not to be used at tempe-ratures below dew point (material deformation)
T = 185 OakAshBeech
HEIHESHBU
ZA0112 1) 271,49
T = 210 OakAshBeech
HEIHESHBU
ZA0112 1) 307,01
T = 260 OakAshBeech
HEIHESHBU
ZA0112 1) 354,24
T = 310 OakAshBeech
HEIHESHBU
ZA0112 1) 401,48
T = 330 OakAshBeech
HEIHESHBU
ZA0112 1) 420,37
T = 360 OakAshBeech
HEIHESHBU
ZA0112 1) 448,70
T = 400 OakAshBeech
HEIHESHBU
ZA0112 1) 486,48
Beech
Stainless steel
Ascotherm® ecoAccessories
84 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Acc
esso
ries
Accessories and miscellaneous
Accessories–fittings
Description Product code Characteristic Dimensions
ProductVersion
Price [EUR]
Connection set, straight form
ZV0110
• VE 5,5 (yellow), kv value 0,15• Only for KRP91 / KRN92Consisting of:• Valve base with factory preset kv valve
– DN 15, both sides 3/4“ external thread with euro taper
– M30 x 1,5– nickel-plated, protective cap
• Return fitting with shut-off– DN 15, both sides 3/4“ external thread with euro
taper– nickel-plated
– ZV0110 0001 41,16
• VE 2,5 (white), kv value 0,30• Only for KRP91 / KRN92 / KRN81Consisting of:• Valve base with factory preset kv valve
– DN 15, both sides 3/4“ external thread with euro taper
– M30 x 1,5– nickel-plated, protective cap
• Return fitting with shut-off– DN 15, both sides 3/4“ external thread with euro
taper– nickel-plated
– ZV0110 0002 41,16
• VE 4,5 (red), kv value 0,54 • Only for KRP91 / KRN92 / KRN81 Consisting of:• Valve base with factory preset kv valve
– DN 15, both sides 3/4“ external thread with euro taper
– M30 x 1,5– nickel-plated, protective cap
• Return fitting with shut-off– DN 15, both sides 3/4“ external thread with euro
taper– nickel-plated
– ZV0110 0003 41,16
• VE 6 (black), kv value 0,98 • Only for KRP91 / KRN 81 / KC2 81 / KC4 81 Consisting of:• Valve base with factory preset kv valve
– DN 15, both sides 3/4“ external thread with euro taper
– M30 x 1,5– nickel-plated, protective cap
• Return fitting with shut-off– DN 15, both sides 3/4“ external thread with euro
taper– nickel-plated
– ZV0110 0004 41,16
• VE 8 (blue), kv value 1,43 • Only for KRN 81 / KC2 81 / KC4 81Consisting of:• Valve base with factory preset kv valve
– DN 15, both sides 3/4“ external thread with euro taper
– M30 x 1,5– nickel-plated, protective cap
• Return fitting with shut-off– DN 15, both sides 3/4“ external thread with euro
taper– nickel-plated
– ZV0110 0005 41,16
Ascotherm® eco Accessories
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 85
Acc
esso
ries
Accessories and miscellaneous
Connection set, angled form
ZV0109
• VE 6 (black), kvs value 0,98 • Only for KC2 81 / KC4 81Consisting of:• Valve base with factory preset kv valve
– DN 15, both sides 3/4“ external thread with euro taper
– M30 x 1,5– nickel-plated, protective cap
• Return fitting with shut-off– DN 15, both sides 3/4“ external thread with euro
taper– nickel-plated
– ZV0109 0001 41,16
• VE 8 (blue), kvs value 1,43 • Only for KC2 81 / KC4 81Consisting of:• Valve base with factory preset kv valve
– DN 15, both sides 3/4“ external thread with euro taper
– M30 x 1,5– nickel-plated, protective cap
• Return fitting with shut-off– DN 15, both sides 3/4“ external thread with euro
taper– nickel-plated
– ZV0109 0002 41,16
Flexible connection
ZT0110
• Incl. 2 double nipples and seals for euro taper• Corrugated hose , stainless steel, DN 16• Operating pressure 10 bar• Temperature resistance up to +90°C (briefly up to
+110°C)• Nuts: brass, internal thread 3/4“, spanner opening 30
mm• Seals: AFM 34• Oxygen diffusion-proof
L = 300 mm ZT0110 0001 28,81
L = 500 mm ZT0110 0002 31,90
Double nipple set
ZT0111 0001
• 2 pcs.• 3/4“ external thread to 3/4“ external thread
– ZT0111 0001 5,66
Air-intake filter
ZK0077
• For KRN 81• 1 roll (5 m)• PPI 30 dark 90x3 mm, with hook & loop strips (1,5 m)
for installation
– ZK0077 0001 22,64
• For KC2 81 / KC4 81• 1 roll (5 m)• PPI 30 dark 140x3 mm, with hook & loop strips (2 m)
for installation
– ZK0077 0002 26,75
Plastic fitting set
ZK0072
• Pipe penetration • For installation in the pipe penetration of the floor
pan (suitable for pipe diameter up to 20 mm)• 10 pcs.
– ZK0072 0001 14,41
• Cable penetration • For installation in the cable penetration of the floor
pan• 5 pcs.
– ZK0072 0002 10,29
Accessories–fittings
Description Product code Characteristic
DimensionsOrdering
code|LAE|
ProductVersion
Price [EUR]
Ascotherm® ecoAccessories
86 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Acc
esso
ries
Accessories and miscellaneous
Accessories-Control technique
Description Product code Characteristic
DimensionsOrdering
code|4|
ProductVersion
Ordering code
|3|Price[EUR]
Room thermo-stat
ZE0077
• Programmable room thermostat, incl. fan control• Only for KRN81 / KC281 / KC481• Temperature control unit, incl. fan control with large
liquid crystal display (LCD) for controlling up to 6 trench convectors
• Energy-saving, automatic blue backlighting• Programmable timer programs• Temperature range 9°C to 32°C• Settings 0,5°C• Frost protection temperature 8°C• Adjustable temperature offset +/5°C• Control of heating/cooling• Voltage supply via BUS cable<• Output relay 5 A• Protection type / protection class: IP30 / II• Plastic casing 81x135x22 for wall mounting (with and
without in-wall pattress box)• Colour similar to RAL9010
– ZE 0077 0003 125,54
• Digital room thermostat• Only for KRP91 / KRN92• Temperature control unit with digital temperature
display• 3 operating modes• Comfort and setback temperature adjustable from
5°C to 30°C• Frost protection temperature adjustable from 5°C to
15°C• Settings 0,5°C• Adjustable temperature offset +/5°C• Voltage supply via AAA batteries (2*1,5V)• Battery charge display, battery change from the front• Output relay 2 A• Protection type / protection class: IP30 / II• Plastic casing 80x80x23 for wall mounting (with and
without in-wall pattress box)• Colour similar to RAL9010
– ZE 0077 0001 68,94
• Programmable room thermostat• Only for KRP91 / KRN92• Temperature control unit with large liquid crystal
display (LCD)• Energy-saving, automatic blue backlighting• Programmable timer programs• 5 operating modes (comfort, set-back, frost protec-
tion, AUTO, Off)• Week or day programming• Voltage supply via AAA batteries (2*1,5V)• Battery charge display, battery change from the front
without loss of program• Output relay 2 A• Protection type / protection class: IP30 / II• Plastic casing 81x135x33 for wall mounting (with and
without in-wall pattress box)• Colour similar to RAL9010
– ZE 0077 0002 107,02
KNX plug-in card
ZE 0078 0001
• Only for KRN81 / KC281 / KC481• For installation on the ASCOTHERM eco control board
to connect to KNX networks, only 1 card needed per convector group (up to 6 convectors)
– ZE 0078 0001 139,94
Ascotherm® eco Accessories
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 87
Acc
esso
ries
Accessories and miscellaneous
Actuator
ZE 0087 0001
• Thermoelectric actuator 24 V DC• Only for KRN 81 / KC2 81 / KC4 81• Operating voltage 24 V DC• Control voltage 0-10 V DC• Power consumption 2 W• Current draw 80 mA• Inrush current max. 350 mA (max 2 min)• Protection type / protection class: IP 54 / III• Operating displacement 4 mm• Incl. VA80 valve adapter and 5 m connecting line• Currentless closed
– ZE 0087 0001 87,47
Actuator
ZE 0023 0001
• Thermoelectric actuator 230 V AC• Only for KRP91 / KRN 92• Operating voltage 230 V AC, 50/60 Hz• Power consumption 1 W• Inrush current max. 320 mA• Protection type / protection class: IP54 / II• Humidity max 80% non-condensing• Currentless closed
– ZE 0023 0001 29,84
Thermostat with fine adjustment
ZV0081 0001
• Only for KRP91 / KRN 92• Threaded connection M30 x 1,5• Capillary pipe 5 m long• casing, white• Temperature range 7 °C to 28 °C• Scaled cap
– 0 Frost protection– 1 - 5
• When a thermostat with remote control is used, other kv settings are needed for the valves; the valve inserts are preset for use with actuators as standard
– ZV0081 0001 94,67
External room temperature sensor
ZE 0080 0001
• Room temperature sensor NTC 10 K with plastic cap, incl. 3-m cable + installation material
– ZE 0080 0001 31,90
Pipe surface sensor
ZE0081
• For sensing the flow temperatures, incl. 2-m cable + installation material, for lengths up to 2000 mm
– ZE 0081 0001 36,02
• For sensing the flow temperatures, incl. 4-m cable + installation material, for lengths over 2000 mm
– ZE 0081 0002 39,10
Dew point monitor
ZE 0082 0001
• Supply voltage 24 V DC• Current draw max. 3 mA• Range 10% to 100% relative humidity• Switching point at 20°C: 90 +/ 3% relative humidity• Reaction time on change of pipe temperature:
t90 < 3 min.• Reaction time on change of room humidity: t90 < 25
sec.• Incl. cable penetration and circuit board plug
– ZE 0082 0001 143,03
Window contact sensor
ZE00830001
• Voltage supply 1 lithium battery 3 V, type CR2032, service life up to 2 years
• Transmission type X2D protocol• Radio frequency 868 MHz• Transmission range up to 300 m (in open area)• Protection type IP 40• Casing ABS/PC
– ZE 0083 0001 81,29
Accessories-Control technique
Description Product code Characteristic
DimensionsOrdering
code|4|
ProductVersion
Ordering code
|3|Price[EUR]
Ascotherm® ecoAccessories
88 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Acc
esso
ries
Accessories and miscellaneous
Assembling aids
Description
Product code Characteristic
DimensionsOrdering
code|4|
Surface / Finish
Ordering code|17|
ProductVersion
Ordering code
|3|Price[EUR]
Spray paint
ZK0002 0007
• RAL 7016 (matt) – Anthracite ZK0002 0007 16,98
Presence detector
ZE00840001
• Voltage supply 230 V with phase and neutral conduc-tor
• Radio frequency 868 MHz• 1 to 2 control channels, depending on function• 3 pre-installed cable for connection to the local
switch, button for up/down• 1 wired phase input from sensor or button• Up to 16 bidirectional RF receivers and any number of
unidirectional RF receivers• Operating temperature -5°C to 40°C• Dimensions: H 50 x B 47 x T 23 mm
– ZE 0084 0001 121,42
RF receiver
ZE 0085 0001
• For use with window contact sensor and presence detector
• Voltage supply via control board• Up to 2x20 transmitters applicable• Transmission range up to 100 m (open area)• Incl. 1-m cable + installation material
– ZE 0085 0001 183,16
Cable
ZE 0086 0001
• For use with RF receiver (ZE00850001)• Length 2 m
– ZE 0086 0001 12,35
Accessories-Control technique
Description Product code Characteristic
DimensionsOrdering
code|4|
ProductVersion
Ordering code
|3|Price[EUR]
Ascotherm® ecoFurther information
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 89
Furt
her
info
rmat
ion
Size and units of measurement
Size and units of measurement
Description Code Units
metre [m]
Millimetre [mm]
Kilogramme [kg]
Degree Celsius [°C]
Kelvin [K]
Joule [J]
Second [s]
Hour [h]
Pascal, kilopascal [Pa, kPa]
Length, height, depth L, H, T [mm]
Floor pan length Lfloor pan [mm]
Ribbed convector length Lribb. [mm]
floor pan height Hfloor pan [mm]
Register height Hreg. [mm]
floor pan depth Tfloor pan [mm]
Register depth Treg. [mm]
Mass M [kg]
Flow-, return temperature t1, t2 [°C]
Room temperature tr [°C]
Mean hot water temperature tm [°C]
Volume flow rate V [m3/h]
Velocity v [m/s]
Pressure loss ∆p [mbar]
Valve coefficient kV –
Adjustable valve coefficient kVS –
Operating pressure, test pressure, air pressure p [bar/Pa]
Sound pressure level Lp [dB/A]
Acoustic power level LW [dB/A]
Internal thread IG –
External thread AG –1) Maximum length: greatest possible length of a delivery unit
Ascotherm® ecoFurther information
90 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Furt
her
info
r-m
atio
n
Size and units of measurement
Size and units of measurement for heating
Description Code Units
Average heat transfer medium temperature EN 442 tm = t1 + t2
2[°C]
Over temperature ∆T [K]
Standard over temperature ΔTn = 49,83 K [K]
Heat output (Phi) Φ [W]
Standard heat output at 75 / 65 / 20 °C (∆T 50 K) (EN 442) Φs [W]
Specific standard heat output ΦL [W/m]
Specific heat capacity cp [J/kgK]
Radiator classification, exponent n –
Correction factor CK –
Water flow rate, standard water flow rate in accordance with EN 442
qm [kg/h]
spec. standard water flow rate according to EN 442 qms [kg/h m]
Size and units of measurement for cooling
Description Code Units
Mean cooling water temperature tm = t1 + t2
2[°C]
Under temperature difference ∆T [K]
Standard under temperature ∆Tn = 9,97 K [K]
Total cooling capacity PK [W]
Total standard cooling capacity PKN [W]
Sensible cooling capacity PS [W]
Sensible standard cooling capacity PSN [W]
Specific heat capacity cp [J/kgK]
Classification, exponent n –
Correction factor CK –
Water flow rate, standard water flow rate in accordance with EN 442
qm [kg/h]
spec. water flow, spec. standard water flow rate according to EN 442
qms [kg/h m]
Relative humidity ϕ [%]
Ascotherm® eco Further information
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 91
Furt
her
info
rmat
ion
Planning, assembly and installation information
Preliminary notes
General
Goods and services are provided exclusively on the basis of our General Terms of Sale, Delivery and Payment.
Technical data
The respective technical data refer to the standard version. Subject to changes and tolerances customary in the industry or necessary for production reasons.
Operating conditions
• For closed hot water heating systems in accordance with DIN 18380 and water quality in accordance with VDI 2035.
• Ascotherm eco trench convectors are not suitable for steam heating systems.
KRP91, KRN92
Company relevant characteristics
Standard version
High-pressure version
Operating pressure [bar (kPa)]
10,0 (1000) 16,0 (1600)
Test pressure [bar (kPa)] 13,0 (1300) 20,8 (2080)
Max. temperature [°C] 110 110
KRN81, KC281, KC481
Company relevant characteristics
Standard version
High-pressure version
Operating pressure [bar (kPa)]
10,0 (1000) 16,0 (1600)
Test pressure [bar (kPa)] 13,0 (1300) 20,8 (2080)
Max. temperature [°C] 90 90
Unless an operating pressure is specified, the standard version will be provided.
Water quality
Operating conditions for water quality in accordance with VDI 2035 must be maintained just as the industry-standard installati-on rules.
Warranty claims according to our General Terms of Sale, Delivery and Payment shall be invalid in the event of:
• periodic or extended draining of the system• operation with steam• addition of substances (e.g. chemicals, antifreeze) to the
heating water that can have a corrosive effect on copper or sealing materials
• excessive sludge deposition in the trench convector• occasional or constant drag-in of oxygen into the system (e.g.
lines and pipes that are not sealed against diffusion) • leaks in the heating system
Special versions according to drawings
If necessary, the customer receives a dimensional drawing for review and approval; the order will be produced after this is returned. In the event that the order is cancelled, the customer must pay compensation for the services and costs incurred up to that point.
Paint finishes
Stoved enamel powder coating (packaged) in all RAL colours according to customer specifications; colour deviations customary in the industry are possible.
Use only original RAL colour samples for colour matching.
For production reasons, paint finishes are subject to slight colour deviations, caused in part by specific light conditions. There may also be differences when comparing painted surfaces with painted ceramic products. Because of limitations in the printing process, the illustrated colours are not binding.
The floor pans and possibly aluminium grilles are finished in accordance with DIN 55900. They must be transported with care and protected against damage at the construction site.
Noises
Noise emission depends on the design, size and fan speed. The acoustic power levels were measured using DIN 45635-1 as a reference.
According to E DIN EN 16430-1 (Fan-assisted radiators, convectors and trench convectors - Part 1: Technical specifications and requi-rements), the sound pressure level can be defined with a room absorption of 8 dB(A). This corresponds to a distance of 2 m from the tested unit, a room volume of 100 m3 and a reverberation time of 0,5 s.
The acoustic characteristics of the room influence the noise level. Accordingly, the actual values may differ. It is recommended that the Ascotherm eco be designed for operation at a moderate speed.
Ascotherm® ecoFurther information
92 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Furt
her
info
r-m
atio
n
Planning, assembly and installation information
Acoustic
Sources of noise cause the air to oscillate; it compresses and expands alternately.
These pressure changes dither the existing air pressure and pro-pagated through the air in sinusoidal form. When these pressure fluctuations reach our ear, the air pressure waves are transfor-med into mechanical vibrations by the eardrum.
The process of hearing is begun.
The human ear only senses the airborne sound; the following two factors are decisive:
a: Sound pressure
b: Frequency
1. Sound pressure
The sound pressure is the change in pressure of the air caused by a sound source. These pressure fluctuations are measured in N/m², and are designated with the letter p.
The sound pressure is a measure of the sound level. It depends on the distance between the sound source and the measurement location as well as the properties of the room.
The sound pressure is unsuitable for calculating the expansion of sound on the sound propagation paths. For this it is necessary to determine the acoustic power of the sound source.
2. Acoustic power
The energy converted into sound by a component (sound source) is called acoustic power. This acoustic power is transmitted to the air in the form of pressure fluctuations.
The acoustic power is a value that cannot be measured directly. It is determined by integrating the acoustic pressure over a hemis-pherical or spherical surface about the sound source.
The acoustic power is thus a value that is independent of space and distance.
It will be used for all of the following calculations.
The acoustic power is stated in watt [W].
For practical use, dimensionless figures have been introduced based on the work of A. G. Bell.
3. Sound pressure level
The logarithmic relationship of a sound pressure p to the refe-rence value p0 is designated acoustic pressure level LP; the unit used to specify it is the decibel [dB].
Lp = 10 lg ( p )2
p0
p = Effective value of the sound pressure at a certain spot in the room
p0 = Reference sound pressure, specified internationally at 2 x 10-5 N/m²
4. Acoustic power level
The acoustic power level LW is defined by:
LW = 10 lg ( P ) in dBP0
P = Acoustic power in watts
P0 = Reference power, specify internationally at 1 x 10-12 watts
The sound pressure level is the sound generated at the sound source (the energy transmitted to the air), while the acoustic pressure level is the sound registered at a certain distance from the sound source.
Thus generally the acoustic power level is larger than the acoustic pressure level.
5. Frequency assessment
Humans perceive the same sound pressure level differently at dif-ferent frequencies. A sound pressure level is generally perceived as quieter and less annoying at low frequencies than at higher frequencies.
In order to take this subjective perception into account, the objectively measured sound pressure levels are adapted to the perception of sound levels. This is called assessment of the sound pressure level.
This assessment is done by subtracting a certain amount from the measured sound pressure level for frequencies that humans are less sensitive to, while adding a certain amount in the other frequency ranges.
Of the various assessments, the A-weighting has become virtually the only one used.
This provides information in the form of a single figure that is designated as an A-weighted acoustic pressure level or an A-weighted sound pressure power.
The unit is called db[A].
6. Sound level additions
If several sound sources are present, then the corresponding levels have to be added to form a total sound level.
The same principles apply here for both the sound pressure level and the acoustic power level.
When there is more than one sound source with the same level, the following relationship applies:
Ltot = L1 + 10 x log n [dB]
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 93
Furt
her
info
rmat
ion
Planning, assembly and installation information
Ascotherm® eco Further information
Calculation: General informationCalculation of the heating requirements of buildings is perfor-med according to the standard DIN EN 12831.
Basic principles heat outputsThe heat outputs of Ascotherm eco trench convectors were measured and established in accordance with E DIN EN 16430 "Fan-assisted radiators, convectors and trench convectors" Part 1: "Technical specifications and requirements" and Part 2 "Test method and rating for thermal output".
Standard heat output ΦS (∆T = 50 K)
The standard heat output ΦS in watts of a radiator indicates the heat flow that is emitted under the following conditions:
- Flow temperature t1 = 75 °C
- Return temperature t2 = 65 °C
- Room temperature tr = 20 °C
- Air pressure p = 1013 hPa
From this follows the average heating water temperature tm in °C.
tr
t1 t2
tm
tm =t1 + t2
=75 + 65
= 70 °C2 2
Calculation
Heat output Φ (deviation from ∆T = 50 K)
For over temperature ∆T deviating from ∆T = 50 K, the heat out-put is calculated as follows:
Φ = ΦS x∆T
n
or Φ = ΦS x CK∆Tn
where n = exponent and CK = correction factor of the heat output characteristic curve (see technical data of the radiators). The over temperature ∆T should be calculated logarithmically as follows:
∆T =(t1 - tr) - (t2 - tr)
=(t1 - t2)
ln(t1 - tr)
ln(t1 - tr)
(t2 - tr) (t2 - tr)
The over temperature ∆T for normal conditions (75 / 65 / 20 °C) is the following as a logarithmic over temperature :
∆Tn =75- 65
= 49.83 K
ln75 - 2065 - 20
Calculation example
KRP91 with L = 3000 mm; H = 120 mm; T = 260 mm
Ascotherm eco:
- Standard heat output ΦS = 1288 watts- Exponent n = 1,43
Operating conditions:
- Flow temperature t1 = 65 °C
- Return temperature t2 = 50 °C
- Room temperature tr = 20 °C
∆T =65 - 50
=15
=15
=15
= 36,99 K
ln65 - 20
ln45 ln1,5 0,4055
50 - 20 30
Φ = ΦS x CK = 1089 x36,99
1,43
= 1288 x 0,653 = 841 W49,83
94 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Furt
her
info
r-m
atio
n
Planning, assembly and installation information
Ascotherm® ecoFurther information
Water flow
Minimum water flow rate
In order to guarantee even temperature distribution in the radi-ator and thus proper heat emission, a minimum water flow must be assured.
For each version, the specific standard water flow rate qms is stated in the performance tables.
The water flow is calculated as follows:
qm [kg/h] =Φ
1,16 x (t1 - t2)
Calculation example
KRP91 with L = 3000 mm; H = 110 mm; T = 260 mm
Φs = 1288 W t1 = 75 °C t2 = 65 °C tr = 20 °C
qm =1288 W
= 111,0 kg/h 1,16 x (75-65)
Calculation example
Φ = 841 W t1 = 65 °C t2 = 50 °C tr = 20 °C
qm =841 W
= 48,3 kg/h 1.16 x (65-50)
Simplified dimensioning
Calculation:
1) Take exponent from table
2) Determine over temperature
3) Determine factor CK from the correction factor table
4) Calculate standard heat output as follows:
Φs =Φ desired
CK
5) Compare calculated value ΦS with table value Φ ∆T 50 K and select corresponding version
Example:
- Flow temperature t1 = 65 °C
- Return temperature t2 = 55 °C
- Room temperature tr = 20 °C
- Desired heat output Φ = 1800 W- Maximum dimensions L = 4500 mm
H = 200 mm T = 360 m
1) n = 1,37
2) Over temperature at 65/55/20 °C = 39,8 K ∼ 40 K3) Factor CK 65/55/20 = 0,7400
4)Φs =
Φ desired=
1800 W= 2432 W
Ck 0,7400
5) KRP91 with L = 4250 mm, H = 150 mm, T = 260 mm, ΦS = 2575 W ≥ 2432 W
or
KRP91 with
L = 3250 mm, H = 200 mm, T = 310 mm, ΦS = 2520 W ≥ 2432 W
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 95
Furt
her
info
rmat
ion
Planning, assembly and installation information, cooling outputs
Ascotherm® eco Further information
Calculation: General informationThe cooling load of buildings is calculated on the basis of VDI 2078.
Basic principles, cooling outputsThe cooling outputs of Ascotherm eco trench convectors were measured and established in accordance with E DIN EN 16430 "Fan-assisted radiators, convectors and trench convectors" Part 1: "Technical specifications and requirements" and Part 3 "Test method and rating for cooling outputs".
Standard cooling output PKN (∆T = 10 K)
The cold air flow generated under the following conditions is designated the total standard cooling output PKN in watts of an Ascotherm eco:
t1 [°C] = Cool water inflow t1 = 16 °C
t2 [°C] = Cool water outflow t2 = 18 °C
tr [°C] = Room temperature tr = 27 °C
Air pressure p = 1013 hPa
Relative humidity ϕ = 50 %
This produces the average cooling water temperature tm in °C.
tm =t1 + t2
=16 + 18
= 17 °C2 2
Calculation
Cooling output PK (when deviating from ∆T = 10 K)
For temperature loss ∆T that deviate from ∆T = 10 K, the cooling output is calculated as follows:
PK = PKN x∆T
n
or PK = PKN x CK∆Tn
where n = exponent and CK = correction factor of the heat out-put characteristic (see technical data). The temperature diffe-rence ∆T should be calculated logarithmically as follows:
∆T =(t1 - tr) - (t2 - tr)
=(t1 - t2)
ln(t1 - tr)
ln(t1 - tr)
(t2 - tr) (t2 - tr)
The under temperature ∆T under standard conditions (16 / 18 / 27 °C) corresponds to the following logarithmic under temperature :
∆Tn =16- 18
= 9,97 K
ln16 - 2718 - 27
Calculation example
KC281 with L = 2000 mm; H = 130 mm; T = 310 mm
Ascotherm eco:
- Total standard cooling output
PKN = 882 watts
- Exponent n = 1,00
- Control voltage 5 V
Operating conditions:
- Flow temperature t1 = 17 °C
- Return temperature t2 = 19 °C
- Room temperature tr = 26 °C
∆T =17 - 19
=2
=2
=2
= 7,96 K
ln17 - 26
ln9 ln1,29 0,2513
19 - 26 7
PK = PKN x CK = 882 x7,96
1,00
= 882 x 0,7984 = 704 W9,97
96 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Furt
her
info
r-m
atio
n
Planning, assembly and installation information, cooling outputs
Ascotherm® ecoFurther information
Water flowFormula for calculating the water flow qm.
qm [kg/h] = PK [W]
1,16 (t2 - t1)
For each version<, the specific standard water flow rate qms is stated in the performance tables.
Calculation example
KC281 with L = 2000 mm, H = 130 mm, T = 310 mm
PKN = 882 W t1 = 16 °C<t2 = 18
°Ctr = 27 °C
qm =882 W
= 380 kg/h 1,16 x (18-16)
Calculation example
PK = 704 W t1 = 17 °C t2 = 19 °C tr = 26 °C
qm =704 W
= 303,45 kg/h 1,16 x (19-17)
Simplified dimensioning
Calculation:
1) Take exponent from table For approximate calculation n = 1,00
2) Determine under temperature
3) Determine factor CK from the correction factor table
4) Calculate standard cooling output as follows:
PKN =Pdesired
CK
5) Compare calculated value PKN with table value and select appropriate version
Example:
- Flow temperature t1 = 17 °C
- Return temperature t2 = 19 °C
- Room temperature tr = 26 °C
- Desired cooling output Pdesired = 1000 W
- Desired version KC 281
- Maximum dimensions L = 2000 mm H = 155 mm T = 360 m
1) n = 1,00
2) Under temperature at 17/19/26 °C = 7,96 K ∼ 8 K3) Factor CK 17/19/26 = 0,8024
4)PKN=
Pdesired=
1000 W= 1246 W
Ck 0,8024
5) KC281 with L = 2000 mm, H = 155 mm, T = 360 mm,
Dimensioning with control voltage of 5 V PKN = 1256 W ≥ 1246 W
or
KC281 with L = 2000 mm, H = 130 mm, T = 310 mm,
Dimensioning with control voltage of 7 V PKN = 1336 W ≥ 1246 W
Note regarding "Basics of cooling outputs":
The calculations above are for a dimensioning with dry cooling. If system parameters that result in condensation on the cooling register are intentionally selected during planning, the sensible cooling output needs to be considered in addition to the total cooling output. In this case, the sensible cooling output is the determining factor for performance the cooling load.
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 97
Furt
her
info
rmat
ion
Planning, assembly and installation information, cooling outputs
Ascotherm® eco Further information
Air tempera-ture
[°C]
Dew point temperature in °C at a relative humidity of
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
5 -24,0 -15,9 -11,2 -7,6 -4,6 -2,2 -0,1 +1,8 +3,5 +5,0
6 -23,1 -15,0 -10,3 -6,6 -3,7 -1,3 +0,8 +2,8 +4,5 +6,0
7 -22,3 -14,2 -9,4 -5,7 -2,8 -0,4 +1,8 +3,8 +5,5 +7,0
8 -21,6 -13,5 -8,5 -4,8 -1,8 +0,6 +2,8 +4,8 +6,5 +8,0
9 -21,0 -12,8 -7,6 -3,8 -0,8 +1,6 +3,8 +5,8 +7,4 +9,0
10 -20,2 -12,0 -6,7 -2,9 +0,1 +2,5 +4,8 +6,8 +8,4 +10,0
11 -19,5 -11,1 -5,9 -2,0 +0,9 +3,5 +5,7 +7,8 +9,4 +11,0
12 -18,7 -10,2 -5,0 -1,2 +1,7 +4,4 +6,6 +8,7 +10,4 +12,0
13 -17,9 -9,4 -4,2 -0,3 +2,6 +5,3 +7,5 +9,7 +11,4 +13,0
14 -17,2 -8,6 -3,3 +0,6 +3,5 +6,2 +8,5 +10,6 +12,3 +14,0
15 -16,5 -7,8 -2,4 +1,5 +4,5 +7,2 +9,5 +11,6 +13,3 +15,0
16 -15,7 -6,9 -1,5 +2,4 +5,5 +8,1 +10,5 +12,6 +14,3 +16,0
17 -14,9 -6,0 -0,7 +3,3 +6,5 +9,1 +11,5 +13,5 +15,3 +17,0
18 -14,1 -5,2 +0,2 +4,2 +7,4 +10,1 +12,4 +14,5 +16,3 +18,0
19 -13,2 -4,5 +1,0 +5,1 +8,3 +11,0 +13,4 +15,4 +17,3 +19,0
20 -12,5 -3,6 +1,9 +6,0 +9,3 +12,0 +14,3 +16,4 +18,3 +20,0
21 -11,7 -2,8 +2,7 +6,8 +10,2 +12,9 +15,3 +17,4 +19,3 +21,0
22 -11,0 -2,0 +3,6 +7,7 +11,1 +13,9 +16,3 +18,3 +20,3 +22,0
23 -10,3 -1,2 +4,5 +8,6 +12,1 +14,7 +17,2 +19,3 +21,2 +23,0
24 -9,6 -0,3 +5,4 +9,5 +12,9 +15,7 +18,2 +20,3 +22,2 +24,0
25 -8,8 +0,5 +6,3 +10,4 +13,8 +16,7 +19,2 +21,3 +23,2 +25,0
26 -8,0 +1,3 +7,1 +11,3 +14,8 +17,7 +20,2 +22,3 +24,2 +26,0
27 -7,3 +2,1 +7,9 +12,2 +15,8 +18,5 +21,0 +23,2 +25,2 +27,0
28 -6,5 +3,0 +8,7 +13,1 +16,7 +19,5 +22,0 +24,2 +26,2 +28,0
29 -5,7 +3,8 +9,6 +14,0 +17,5 +20,4 +23,0 +25,2 +27,2 +29,0
30 -5,0 +4,6 +10,5 +14,9 +18,4 +21,4 +24,0 +26,2 +28,2 +30,0
Example of system dimensioning under normal conditions
Dew point tableFor a correct dry cooling dimensioning without condensation, the flow temperature of the cool water needs to be taken into account. The flow temperature of the cooling water can be taken as the lowest possible surface temperature of fin compon-ents. Assuming normal conditions (room air temperature 27 °C, relative humidity 50%), the
dew point will be 15.8 °C. This means that condensation can be expected if the flow temperature of the cool water drops below 15.8 °C. Beneficial drying effects associated with fan operation are not taken into account, since this effect depends largely on the fan speed.
98 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Furt
her
info
r-m
atio
n
Planning, assembly and installation information
Ascotherm® ecoFurther information
Over temperatures ∆T (logarithmic calculation)
Flow temperature
t1 °C
Room temperature
tr °C
Return temperature t2 °C
30 35 40 45 50 55 60 65 70 75
90 24 30,7 35,3 39,3 42,9 46,3 49,5 52,5 55,4 58,2
22 33,2 37,6 41,5 45,1 48,4 51,6 54,5 57,4 60,2
20 30,8 35,7 39,9 43,7 47,2 50,5 53,6 56,6 59,4 62,2
18 33,5 38,1 42,2 45,9 49,3 52,6 55,7 58,6 61,5 64,2
15 37,3 41,6 45,5 49,1 52,5 55,7 58,7 61,7 64,5 67,2
85 24 29,2 33,6 37,5 41,0 44,3 47,4 50,3 53,1 55,9
22 31,7 35,9 39,7 43,2 46,4 49,5 52,4 55,2 57,9
20 29,4 34,1 38,2 41,9 45,3 48,5 51,5 54,4 57,2 59,9
18 32,0 36,5 40,4 44,0 47,4 50,5 53,5 56,4 59,2 61,9
15 35,7 39,9 43,7 47,2 50,5 53,6 56,6 59,4 62,2 64,9
80 24 27,7 31,9 35,7 39,1 42,3 45,3 48,1 50,8 53,5
22 30,1 34,2 37,8 41,2 44,3 47,3 50,1 52,8 55,5
20 27,9 32,5 36,4 40,0 43,3 46,4 49,3 52,1 54,8 57,5
18 30,4 34,8 38,6 42,1 45,4 48,4 51,4 54,2 56,9 59,5
15 34,1 38,2 41,9 45,3 48,5 51,5 54,4 57,2 59,9 62,5
75 24 26,1 30,2 33,8 37,1 40,2 43,1 45,8 48,5
22 28,5 32,4 35,9 39,2 42,2 45,1 47,8 50,5
20 26,4 30,8 34,6 38,0 41,2 44,2 47,1 49,8 52,5
18 28,9 33,1 36,8 40,1 43,3 46,3 49,1 51,8 54,5
15 32,5 36,4 40,0 43,3 46,4 49,3 52,1 54,8 57,5
70 24 24,5 28,4 31,9 35,1 38,0 40,8 43,5
22 26,8 30,6 34,0 37,1 40,0 42,8 45,5
20 24,9 29,1 32,7 36,1 39,2 42,1 44,8 47,5
18 27,3 31,3 34,9 38,1 41,2 44,1 46,8 49,5
15 30,8 34,6 38,0 41,2 44,2 47,1 49,8 52,5
65 24 22,8 26,6 29,9 32,9 35,8 38,4
22 25,1 28,7 32,0 35,0 37,8 40,4
20 23,3 27,3 30,8 34,0 37,0 39,8 42,5
18 25,6 29,5 32,9 36,1 39,0 41,8 44,5
15 29,1 32,7 36,1 39,2 42,1 44,8 47,5
60 24 21,1 24,7 27,8 30,7 33,4
22 23,3 26,8 29,9 32,7 35,4
20 21,6 25,5 28,9 31,9 34,8 37,4
18 23,9 27,6 30,9 33,9 36,8 39,4
15 27,3 30,8 34,0 37,0 39,8 42,5
55 24 19,3 22,7 25,7 28,4
22 21,5 24,7 27,7 30,4
20 20,0 23,6 26,8 29,7 32,4
18 22,2 25,7 28,9 31,7 34,4
15 25,5 28,9 31,9 34,8 37,4
50 24 17,4 20,6 23,4
22 19,6 22,6 25,4
20 18,2 21,6 24,7 27,4
18 20,4 23,7 26,7 29,4
15 23,6 26,8 29,7 32,4
45 24 15,5 18,4
22 17,5 20,4
20 16,4 19,6 22,4
18 18,5 21,6 24,4
15 21,6 24,7 27,4
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 99
Furt
her
info
rmat
ion
Planning, assembly and installation information, heat output correction factors
Ascotherm® eco Further information
Correction factors CK (logarithmic calculation)
∆T [K]Exponent n
∆T [K]1,00 1,28 1,29 1,30 1,31 1,32 1,33 1,34 1,35 1,36 1,37 1,38 1,39
10 0,2007 0,1280 0,1260 0,1239 0,1220 0,1200 0,1181 0,1162 0,1144 0,1126 0,1108 0,1090 0,1073 1011 0,2207 0,1446 0,1424 0,1403 0,1382 0,1361 0,1341 0,1321 0,1301 0,1281 0,1262 0,1243 0,1225 1112 0,2408 0,1616 0,1593 0,1571 0,1549 0,1527 0,1505 0,1484 0,1463 0,1442 0,1422 0,1402 0,1382 1213 0,2609 0,1791 0,1767 0,1743 0,1720 0,1697 0,1674 0,1652 0,1630 0,1608 0,1587 0,1566 0,1545 1314 0,2809 0,1969 0,1944 0,1920 0,1895 0,1871 0,1848 0,1824 0,1801 0,1779 0,1756 0,1734 0,1712 1415 0,3010 0,2151 0,2125 0,2100 0,2075 0,2050 0,2025 0,2001 0,1977 0,1954 0,1930 0,1907 0,1885 1516 0,3211 0,2336 0,2310 0,2283 0,2258 0,2232 0,2207 0,2182 0,2157 0,2133 0,2109 0,2085 0,2061 1617 0,3411 0,2524 0,2497 0,2471 0,2444 0,2418 0,2392 0,2367 0,2341 0,2316 0,2291 0,2267 0,2243 1718 0,3612 0,2716 0,2688 0,2661 0,2634 0,2608 0,2581 0,2555 0,2529 0,2504 0,2478 0,2453 0,2428 1819 0,3813 0,2911 0,2883 0,2855 0,2828 0,2800 0,2774 0,2747 0,2721 0,2695 0,2669 0,2643 0,2618 19
20 0,4013 0,3108 0,3080 0,3052 0,3024 0,2997 0,2969 0,2942 0,2916 0,2889 0,2863 0,2837 0,2811 2021 0,4214 0,3308 0,3280 0,3252 0,3224 0,3196 0,3169 0,3141 0,3114 0,3087 0,3061 0,3035 0,3008 2122 0,4415 0,3511 0,3483 0,3454 0,3426 0,3398 0,3371 0,3343 0,3316 0,3289 0,3262 0,3236 0,3209 2223 0,4615 0,3717 0,3688 0,3660 0,3632 0,3604 0,3576 0,3548 0,3521 0,3494 0,3467 0,3440 0,3414 2324 0,4816 0,3925 0,3897 0,3868 0,3840 0,3812 0,3784 0,3757 0,3729 0,3702 0,3675 0,3649 0,3622 2425 0,5017 0,4136 0,4107 0,4079 0,4051 0,4023 0,3995 0,3968 0,3941 0,3914 0,3887 0,3860 0,3833 2526 0,5217 0,4349 0,4320 0,4292 0,4265 0,4237 0,4209 0,4182 0,4155 0,4128 0,4101 0,4075 0,4048 2627 0,5418 0,4564 0,4536 0,4508 0,4481 0,4453 0,4426 0,4399 0,4372 0,4345 0,4319 0,4292 0,4266 2728 0,5619 0,4781 0,4754 0,4726 0,4699 0,4672 0,4645 0,4619 0,4592 0,4566 0,4540 0,4513 0,4487 2829 0,5819 0,5001 0,4974 0,4947 0,4920 0,4894 0,4867 0,4841 0,4815 0,4789 0,4763 0,4737 0,4712 2930 0,6020 0,5223 0,5196 0,5170 0,5144 0,5118 0,5092 0,5066 0,5040 0,5015 0,4990 0,4964 0,4939 3031 0,6221 0,5447 0,5421 0,5395 0,5370 0,5344 0,5319 0,5294 0,5269 0,5244 0,5219 0,5194 0,5169 3132 0,6421 0,5672 0,5647 0,5622 0,5598 0,5573 0,5548 0,5524 0,5499 0,5475 0,5451 0,5427 0,5403 3233 0,6622 0,5900 0,5876 0,5852 0,5828 0,5804 0,5780 0,5756 0,5733 0,5709 0,5685 0,5662 0,5639 3334 0,6823 0,6130 0,6107 0,6083 0,6060 0,6037 0,6014 0,5991 0,5968 0,5946 0,5923 0,5900 0,5878 3435 0,7023 0,6362 0,6339 0,6317 0,6295 0,6273 0,6250 0,6228 0,6206 0,6185 0,6163 0,6141 0,6119 3536 0,7224 0,6595 0,6574 0,6553 0,6531 0,6510 0,6489 0,6468 0,6447 0,6426 0,6405 0,6384 0,6364 3637 0,7425 0,6831 0,6811 0,6790 0,6770 0,6750 0,6730 0,6710 0,6690 0,6670 0,6650 0,6630 0,6611 3738 0,7625 0,7068 0,7049 0,7030 0,7011 0,6992 0,6973 0,6954 0,6935 0,6916 0,6898 0,6879 0,6860 3839 0,7826 0,7307 0,7289 0,7271 0,7254 0,7236 0,7218 0,7200 0,7183 0,7165 0,7148 0,7130 0,7113 3940 0,8027 0,7548 0,7531 0,7515 0,7498 0,7482 0,7465 0,7449 0,7432 0,7416 0,7400 0,7384 0,7367 4041 0,8227 0,7790 0,7775 0,7760 0,7745 0,7730 0,7714 0,7699 0,7684 0,7669 0,7655 0,7640 0,7625 4142 0,8428 0,8034 0,8020 0,8007 0,7993 0,7979 0,7966 0,7952 0,7939 0,7925 0,7911 0,7898 0,7884 4243 0,8629 0,8280 0,8268 0,8255 0,8243 0,8231 0,8219 0,8207 0,8195 0,8183 0,8171 0,8159 0,8147 4344 0,8830 0,8527 0,8516 0,8506 0,8495 0,8485 0,8474 0,8464 0,8453 0,8443 0,8432 0,8422 0,8411 4445 0,9030 0,8776 0,8767 0,8758 0,8749 0,8740 0,8731 0,8722 0,8713 0,8705 0,8696 0,8687 0,8678 4546 0,9231 0,9026 0,9019 0,9012 0,9005 0,8997 0,8990 0,8983 0,8976 0,8969 0,8962 0,8954 0,8947 4647 0,9432 0,9278 0,9273 0,9267 0,9262 0,9257 0,9251 0,9246 0,9240 0,9235 0,9229 0,9224 0,9219 4748 0,9632 0,9532 0,9528 0,9525 0,9521 0,9517 0,9514 0,9510 0,9507 0,9503 0,9500 0,9496 0,9492 4849 0,9833 0,9787 0,9785 0,9783 0,9782 0,9780 0,9778 0,9777 0,9775 0,9773 0,9772 0,9770 0,9768 4950 1,0034 1,0043 1,0043 1,0044 1,0044 1,0044 1,0045 1,0045 1,0045 1,0046 1,0046 1,0046 1,0047 5051 1,0234 1,0301 1,0303 1,0306 1,0308 1,0310 1,0313 1,0315 1,0317 1,0320 1,0322 1,0325 1,0327 5152 1,0435 1,0560 1,0564 1,0569 1,0573 1,0578 1,0582 1,0587 1,0592 1,0596 1,0601 1,0605 1,0610 5253 1,0636 1,0821 1,0827 1,0834 1,0841 1,0847 1,0854 1,0861 1,0867 1,0874 1,0881 1,0888 1,0894 5354 1,0836 1,1083 1,1092 1,1100 1,1109 1,1118 1,1127 1,1136 1,1145 1,1154 1,1163 1,1172 1,1181 5455 1,1037 1,1346 1,1357 1,1368 1,1380 1,1391 1,1402 1,1413 1,1425 1,1436 1,1447 1,1459 1,1470 5556 1,1238 1,1611 1,1624 1,1638 1,1651 1,1665 1,1679 1,1692 1,1706 1,1720 1,1733 1,1747 1,1761 5657 1,1438 1,1877 1,1893 1,1909 1,1925 1,1941 1,1957 1,1973 1,1989 1,2005 1,2021 1,2037 1,2054 5758 1,1639 1,2144 1,2163 1,2181 1,2200 1,2218 1,2237 1,2255 1,2274 1,2293 1,2311 1,2330 1,2349 5859 1,1840 1,2413 1,2434 1,2455 1,2476 1,2497 1,2518 1,2539 1,2560 1,2582 1,2603 1,2624 1,2646 5960 1,2040 1,2683 1,2706 1,2730 1,2754 1,2777 1,2801 1,2825 1,2849 1,2873 1,2896 1,2920 1,2944 6061 1,2241 1,2954 1,2980 1,3006 1,3033 1,3059 1,3086 1,3112 1,3139 1,3165 1,3192 1,3219 1,3245 6162 1,2442 1,3226 1,3255 1,3284 1,3313 1,3342 1,3372 1,3401 1,3430 1,3460 1,3489 1,3518 1,3548 6263 1,2642 1,3500 1,3532 1,3564 1,3595 1,3627 1,3659 1,3691 1,3723 1,3756 1,3788 1,3820 1,3853 6364 1,2843 1,3775 1,3809 1,3844 1,3879 1,3913 1,3948 1,3983 1,4018 1,4053 1,4089 1,4124 1,4159 6465 1,3044 1,4051 1,4088 1,4126 1,4163 1,4201 1,4239 1,4277 1,4315 1,4353 1,4391 1,4429 1,4468 6566 1,3244 1,4328 1,4369 1,4409 1,4450 1,4490 1,4531 1,4572 1,4613 1,4654 1,4695 1,4737 1,4778 6667 1,3445 1,4607 1,4650 1,4694 1,4737 1,4781 1,4825 1,4869 1,4913 1,4957 1,5001 1,5046 1,5090 6768 1,3646 1,4886 1,4933 1,4979 1,5026 1,5073 1,5120 1,5167 1,5214 1,5261 1,5309 1,5356 1,5404 6869 1,3846 1,5167 1,5217 1,5266 1,5316 1,5366 1,5416 1,5466 1,5517 1,5567 1,5618 1,5669 1,5720 69
100 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Furt
her
info
r-m
atio
n
Planning, assembly and installation information, heat output correction factors
Ascotherm® ecoFurther information
Correction factors CK (logarithmic calculation)
∆T [K]Exponent n
∆T [K]1,40 1,41 1,42 1,43 1,44 1,45 1,47 1,48 1,49 1,65 1,70 1,72 1,93
10 0,1056 0,1039 0,1022 0,1006 0,0990 0,0974 0,0943 0,0928 0,0913 0,0706 0,0652 0,0631 0,0451 1011 0,1206 0,1188 0,1170 0,1153 0,1135 0,1118 0,1085 0,1069 0,1053 0,0827 0,0767 0,0744 0,0542 1112 0,1362 0,1343 0,1324 0,1306 0,1287 0,1269 0,1233 0,1216 0,1199 0,0954 0,0889 0,0864 0,0641 1213 0,1524 0,1504 0,1484 0,1464 0,1444 0,1425 0,1387 0,1369 0,1350 0,1089 0,1018 0,0991 0,0748 1314 0,1691 0,1669 0,1648 0,1627 0,1607 0,1587 0,1547 0,1527 0,1508 0,1231 0,1155 0,1126 0,0863 1415 0,1862 0,1840 0,1818 0,1796 0,1775 0,1754 0,1712 0,1692 0,1671 0,1379 0,1299 0,1268 0,0985 1516 0,2038 0,2015 0,1992 0,1970 0,1948 0,1926 0,1882 0,1861 0,1840 0,1534 0,1450 0,1417 0,1116 1617 0,2219 0,2195 0,2172 0,2148 0,2125 0,2103 0,2058 0,2036 0,2014 0,1696 0,1607 0,1573 0,1255 1718 0,2404 0,2379 0,2355 0,2331 0,2308 0,2284 0,2238 0,2216 0,2193 0,1863 0,1771 0,1735 0,1401 1819 0,2593 0,2568 0,2543 0,2519 0,2494 0,2471 0,2423 0,2400 0,2377 0,2037 0,1941 0,1904 0,1555 19
20 0,2786 0,2760 0,2735 0,2710 0,2686 0,2661 0,2613 0,2589 0,2566 0,2217 0,2118 0,2080 0,1717 2021 0,2983 0,2957 0,2931 0,2906 0,2881 0,2856 0,2807 0,2783 0,2759 0,2403 0,2301 0,2262 0,1887 2122 0,3183 0,3157 0,3132 0,3106 0,3081 0,3056 0,3006 0,2982 0,2957 0,2595 0,2491 0,2450 0,2064 2223 0,3388 0,3362 0,3336 0,3310 0,3284 0,3259 0,3209 0,3184 0,3160 0,2792 0,2686 0,2645 0,2249 2324 0,3596 0,3569 0,3543 0,3518 0,3492 0,3467 0,3416 0,3391 0,3367 0,2995 0,2888 0,2846 0,2441 2425 0,3807 0,3781 0,3755 0,3729 0,3703 0,3678 0,3628 0,3603 0,3578 0,3204 0,3095 0,3053 0,2641 2526 0,4022 0,3996 0,3970 0,3944 0,3919 0,3893 0,3843 0,3818 0,3793 0,3418 0,3309 0,3266 0,2849 2627 0,4240 0,4214 0,4189 0,4163 0,4138 0,4112 0,4062 0,4037 0,4013 0,3638 0,3528 0,3485 0,3064 2728 0,4462 0,4436 0,4411 0,4385 0,4360 0,4335 0,4285 0,4261 0,4236 0,3863 0,3753 0,3710 0,3287 2829 0,4686 0,4661 0,4636 0,4611 0,4586 0,4561 0,4512 0,4488 0,4463 0,4093 0,3984 0,3941 0,3517 2930 0,4914 0,4889 0,4865 0,4840 0,4815 0,4791 0,4743 0,4719 0,4695 0,4329 0,4220 0,4178 0,3755 3031 0,5145 0,5121 0,5096 0,5072 0,5048 0,5024 0,4977 0,4953 0,4930 0,4569 0,4462 0,4420 0,4001 3132 0,5379 0,5355 0,5331 0,5308 0,5284 0,5261 0,5215 0,5192 0,5169 0,4815 0,4710 0,4668 0,4253 3233 0,5616 0,5593 0,5570 0,5547 0,5524 0,5501 0,5456 0,5433 0,5411 0,5066 0,4962 0,4922 0,4514 3334 0,5855 0,5833 0,5811 0,5789 0,5766 0,5744 0,5701 0,5679 0,5657 0,5322 0,5221 0,5181 0,4781 3435 0,6098 0,6076 0,6055 0,6034 0,6012 0,5991 0,5949 0,5928 0,5907 0,5582 0,5485 0,5446 0,5056 3536 0,6343 0,6323 0,6302 0,6282 0,6261 0,6241 0,6200 0,6180 0,6160 0,5848 0,5754 0,5716 0,5339 3637 0,6591 0,6572 0,6552 0,6533 0,6513 0,6494 0,6455 0,6436 0,6417 0,6118 0,6028 0,5992 0,5629 3738 0,6842 0,6823 0,6805 0,6786 0,6768 0,6750 0,6713 0,6695 0,6677 0,6394 0,6307 0,6273 0,5926 3839 0,7095 0,7078 0,7061 0,7043 0,7026 0,7009 0,6975 0,6957 0,6940 0,6674 0,6592 0,6560 0,6231 3940 0,7351 0,7335 0,7319 0,7303 0,7287 0,7271 0,7239 0,7223 0,7207 0,6958 0,6882 0,6852 0,6543 4041 0,7610 0,7595 0,7580 0,7565 0,7551 0,7536 0,7507 0,7492 0,7477 0,7248 0,7177 0,7149 0,6862 4142 0,7871 0,7857 0,7844 0,7831 0,7817 0,7804 0,7777 0,7764 0,7751 0,7542 0,7477 0,7452 0,7189 4243 0,8135 0,8123 0,8111 0,8099 0,8087 0,8075 0,8051 0,8039 0,8027 0,7840 0,7782 0,7760 0,7523 4344 0,8401 0,8390 0,8380 0,8369 0,8359 0,8348 0,8328 0,8317 0,8307 0,8143 0,8093 0,8073 0,7864 4445 0,8669 0,8660 0,8651 0,8643 0,8634 0,8625 0,8607 0,8599 0,8590 0,8451 0,8408 0,8391 0,8213 4546 0,8940 0,8933 0,8926 0,8919 0,8911 0,8904 0,8890 0,8883 0,8876 0,8763 0,8728 0,8714 0,8569 4647 0,9213 0,9208 0,9203 0,9197 0,9192 0,9186 0,9176 0,9170 0,9165 0,9079 0,9053 0,9042 0,8932 4748 0,9489 0,9485 0,9482 0,9478 0,9475 0,9471 0,9464 0,9460 0,9457 0,9400 0,9383 0,9376 0,9302 4849 0,9767 0,9765 0,9764 0,9762 0,9760 0,9759 0,9755 0,9754 0,9752 0,9726 0,9718 0,9714 0,9680 4950 1,0047 1,0047 1,0048 1,0048 1,0048 1,0049 1,0049 1,0050 1,0050 1,0055 1,0057 1,0058 1,0065 5051 1,0329 1,0332 1,0334 1,0337 1,0339 1,0341 1,0346 1,0349 1,0351 1,0389 1,0401 1,0406 1,0457 5152 1,0614 1,0619 1,0623 1,0628 1,0632 1,0637 1,0646 1,0650 1,0655 1,0728 1,0750 1,0760 1,0856 5253 1,0901 1,0908 1,0914 1,0921 1,0928 1,0935 1,0948 1,0955 1,0962 1,1070 1,1104 1,1118 1,1263 5354 1,1190 1,1199 1,1208 1,1217 1,1226 1,1235 1,1253 1,1262 1,1271 1,1417 1,1463 1,1481 1,1677 5455 1,1481 1,1492 1,1504 1,1515 1,1527 1,1538 1,1561 1,1572 1,1584 1,1768 1,1826 1,1849 1,2097 5556 1,1774 1,1788 1,1802 1,1816 1,1830 1,1843 1,1871 1,1885 1,1899 1,2123 1,2194 1,2222 1,2526 5657 1,2070 1,2086 1,2102 1,2119 1,2135 1,2151 1,2184 1,2200 1,2217 1,2482 1,2566 1,2600 1,2961 5758 1,2367 1,2386 1,2405 1,2424 1,2443 1,2462 1,2499 1,2518 1,2537 1,2846 1,2943 1,2983 1,3403 5859 1,2667 1,2688 1,2710 1,2731 1,2753 1,2774 1,2818 1,2839 1,2861 1,3213 1,3325 1,3370 1,3853 5960 1,2968 1,2993 1,3017 1,3041 1,3065 1,3089 1,3138 1,3163 1,3187 1,3585 1,3711 1,3762 1,4310 6061 1,3272 1,3299 1,3326 1,3353 1,3380 1,3407 1,3461 1,3489 1,3516 1,3960 1,4102 1,4159 1,4773 6162 1,3578 1,3607 1,3637 1,3667 1,3697 1,3727 1,3787 1,3817 1,3847 1,4340 1,4497 1,4561 1,5244 6263 1,3885 1,3918 1,3951 1,3983 1,4016 1,4049 1,4115 1,4148 1,4181 1,4723 1,4897 1,4967 1,5722 6364 1,4195 1,4230 1,4266 1,4302 1,4338 1,4374 1,4446 1,4482 1,4518 1,5111 1,5301 1,5378 1,6208 6465 1,4506 1,4545 1,4584 1,4622 1,4661 1,4700 1,4779 1,4818 1,4857 1,5503 1,5710 1,5794 1,6700 6566 1,4820 1,4861 1,4903 1,4945 1,4987 1,5029 1,5114 1,5157 1,5199 1,5898 1,6123 1,6214 1,7199 6667 1,5135 1,5180 1,5225 1,5270 1,5315 1,5361 1,5452 1,5498 1,5544 1,6298 1,6541 1,6639 1,7706 6768 1,5452 1,5500 1,5549 1,5597 1,5646 1,5694 1,5792 1,5841 1,5891 1,6701 1,6962 1,7068 1,8219 6869 1,5771 1,5823 1,5874 1,5926 1,5978 1,6030 1,6135 1,6187 1,6240 1,7108 1,7389 1,7502 1,8740 69
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 101
Furt
her
info
rmat
ion
Planning, assembly and installation information, cooling capacity correction factors
Ascotherm® eco Further information
Correction factors CK (logarithmic calculation)
∆T [K]Exponent n
∆T [K]0,68 0,72 0,74 0,76 0,78 0,79 0,83 0,90 0,91 0,92 0,93
8 0,8610 0,8534 0,8497 0,8459 0,8422 0,8404 0,8330 0,8203 0,8185 0,8167 0,8149 89 0,9328 0,9290 0,9271 0,9252 0,9233 0,9223 0,9186 0,9120 0,9111 0,9101 0,9092 910 1,0020 1,0022 1,0022 1,0023 1,0023 1,0024 1,0025 1,0027 1,0027 1,0028 1,0028 1011 1,0691 1,0734 1,0755 1,0776 1,0797 1,0808 1,0850 1,0925 1,0936 1,0947 1,0957 1112 1,1343 1,1427 1,1470 1,1512 1,1555 1,1577 1,1663 1,1815 1,1837 1,1859 1,1881 1213 1,1978 1,2105 1,2170 1,2235 1,2300 1,2332 1,2464 1,2698 1,2731 1,2765 1,2799 1314 1,2597 1,2769 1,2856 1,2943 1,3032 1,3076 1,3255 1,3573 1,3620 1,3666 1,3712 1415 1,3202 1,3419 1,3529 1,3640 1,3752 1,3808 1,4036 1,4443 1,4502 1,4561 1,4621 1516 1,3794 1,4057 1,4191 1,4326 1,4462 1,4531 1,4808 1,5307 1,5379 1,5452 1,5525 1617 1,4374 1,4685 1,4842 1,5001 1,5162 1,5244 1,5572 1,6165 1,6252 1,6339 1,6426 1718 1,4944 1,5302 1,5483 1,5667 1,5854 1,5948 1,6329 1,7018 1,7119 1,7221 1,7323 1819 1,5504 1,5909 1,6115 1,6325 1,6537 1,6644 1,7078 1,7867 1,7983 1,8099 1,8216 1920 1,6054 1,6507 1,6739 1,6974 1,7212 1,7332 1,7821 1,8711 1,8842 1,8974 1,9106 2021 1,6596 1,7098 1,7354 1,7615 1,7879 1,8013 1,8558 1,9551 1,9697 1,9845 1,9993 2122 1,7129 1,7680 1,7962 1,8249 1,8540 1,8687 1,9288 2,0387 2,0549 2,0712 2,0877 2223 1,7655 1,8255 1,8563 1,8876 1,9194 1,9355 2,0013 2,1219 2,1397 2,1577 2,1758 2324 1,8173 1,8823 1,9157 1,9496 1,9842 2,0017 2,0733 2,2048 2,2242 2,2439 2,2637 2425 1,8685 1,9385 1,9744 2,0111 2,0484 2,0673 2,1447 2,2873 2,3084 2,3297 2,3512 2526 1,9190 1,9940 2,0326 2,0719 2,1120 2,1324 2,2157 2,3695 2,3923 2,4153 2,4386 2627 1,9689 2,0489 2,0901 2,1322 2,1751 2,1969 2,2862 2,4513 2,4759 2,5007 2,5257 27
∆T [K]Exponent n
∆T [K]0,94 0,95 0,97 1,00 1,02 1,04 1,05 1,06 1,10 1,12 1,19
8 0,8131 0,8113 0,8077 0,8024 0,7989 0,7954 0,7936 0,7919 0,7849 0,7815 0,7695 89 0,9083 0,9073 0,9055 0,9027 0,9009 0,8990 0,8981 0,8972 0,8935 0,8917 0,8853 910 1,0028 1,0029 1,0029 1,0030 1,0031 1,0031 1,0032 1,0032 1,0033 1,0034 1,0036 1011 1,0968 1,0979 1,1001 1,1033 1,1055 1,1077 1,1087 1,1098 1,1142 1,1164 1,1241 1112 1,1903 1,1925 1,1969 1,2036 1,2081 1,2126 1,2148 1,2171 1,2261 1,2307 1,2467 1213 1,2833 1,2867 1,2936 1,3039 1,3109 1,3178 1,3213 1,3248 1,3390 1,3461 1,3713 1314 1,3759 1,3806 1,3900 1,4042 1,4138 1,4234 1,4283 1,4331 1,4527 1,4626 1,4978 1415 1,4681 1,4741 1,4862 1,5045 1,5169 1,5293 1,5356 1,5418 1,5672 1,5801 1,6259 1516 1,5599 1,5673 1,5822 1,6048 1,6201 1,6355 1,6432 1,6510 1,6825 1,6985 1,7557 1617 1,6514 1,6602 1,6780 1,7051 1,7234 1,7419 1,7512 1,7606 1,7986 1,8179 1,8871 1718 1,7425 1,7529 1,7737 1,8054 1,8269 1,8486 1,8595 1,8706 1,9153 1,9381 2,0199 1819 1,8334 1,8453 1,8692 1,9057 1,9305 1,9555 1,9682 1,9809 2,0327 2,0590 2,1541 1920 1,9240 1,9374 1,9646 2,0060 2,0341 2,0627 2,0771 2,0916 2,1506 2,1808 2,2897 2021 2,0142 2,0293 2,0598 2,1063 2,1379 2,1700 2,1863 2,2026 2,2692 2,3033 2,4266 2122 2,1043 2,1210 2,1548 2,2066 2,2418 2,2776 2,2957 2,3139 2,3884 2,4265 2,5647 2223 2,1941 2,2125 2,2498 2,3069 2,3458 2,3854 2,4054 2,4256 2,5080 2,5503 2,7040 2324 2,2836 2,3038 2,3446 2,4072 2,4499 2,4933 2,5153 2,5375 2,6283 2,6748 2,8445 2425 2,3730 2,3949 2,4393 2,5075 2,5541 2,6014 2,6255 2,6497 2,7490 2,8000 2,9861 2526 2,4621 2,4858 2,5339 2,6078 2,6583 2,7098 2,7358 2,7622 2,8702 2,9257 3,1288 2627 2,5510 2,5765 2,6284 2,7081 2,7626 2,8182 2,8464 2,8749 2,9918 3,0520 3,2725 27
Ascotherm® ecoFurther information
102 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Furt
her
info
r-m
atio
n
Planning, assembly and installation instructions
Scope of delivery• External, adjustable and acoustically decoupled height adjust-
ments (pre-installed)• For KRP91, KRN92 and KRN81 aluminium linear grille (on
request, delivery can be postponed until the end of the construction phase)
• For KC281 and KC481 aluminium roll-up grille (on request, delivery can be postponed until the end of the construction phase)
• Plastic elements for acoustic decoupling• Installation cover and edge bar protection (for protection
during the construction phase)
Planning advices• To compensate for cold air that occurs on large window areas,
the trench convectors must be dimensioned to extend along the entire length of the window.
• The thermal behaviour of screeds and floors can compress the floor pans of trench convectors. To prevent this, expansion joints must be provided.
• When electrical cables or a thermostatic sensor head with a remote sensor will be used, it is necessary to install an empty conduit.
• The installation cover supplied serves to protect the convec-tor during the construction phase and should be replaced with the supplied linear grille or roll-up grille only after all construction work has been completed. The installation cover has only limited loading capability and is not suitable for use as a surface to support scaffolds, ladders etc.
• The convector must be accessible for maintenance work at any time.
Installation instructions
Positioning and arrangement
• Remove the packaging film and packaging cardboard from the trench convector before installation. If the top grille has already been delivered, store it in a safe location until construction work has been completed.
• Place the trench convector in position and use the external height adjustments to align it. The height adjustments can be placed in the correct position with the aid of a screwdriver.
• Use the mounting brackets to secure the floor pan to the floor.
• If necessary, use insulation underneath and on the sides of the floor pan as well.
• Note the acoustic decoupling
Connecting of the trench convector
• Water connection to the face (as standard) or room sided with openings already provided for pipe entry (on request, other connection arrangements also possible).
• Attach fittings and connect convector to pipework.• To prevent entry of screed into the floor pan, seal the provi-
ded openings with suitable material. (e. g. plastic plugs from the accessory range)
• Perform a pressure test.• Cover the convector with the supplied installation cover for
protection• When components from other manufacturers are used (e.g.
connection set, actuator,…) that are not in the accessory range for the Ascotherm eco, pay attention to the installation dimensions.
Intended use
The Ascotherm KRN81, KC281 and KC481 are intended exclusi-vely for use in indoor areas (e.g. conservatories, residential and commercial areas, showrooms, etc. The Ascotherm KRN81, KC281 and KC481 cannot be used in swimming pools, damp locations and outdoor areas. In case of doubt, always consult the manufac-turer. Any other or additional use shall be considered as impro-per use.
Safety instructions
• Electrical work may be carried out only by authorised electri-cians. Connection must comply with valid VDE regulations and the EVU directives.
• When installing Ascotherm KRN81, KC281 and KC481, a suita-ble residual current-operated protective device (RCD) / earth leakage circuit breaker (less than or equal to 30 mA) must be installed.
• In case of failure to comply with the regulations and directives malfunctions with consequential damage and endangerment of individuals can occur. Mixing up wires or connecting impro-perly can result in MORTAL DANGER!
• Note additional safety information in the installation instruc-tions.
Ascotherm® eco KRP91Further information
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 103
Ordering process
Furt
her
info
rmat
ion
Product Flow/return Floor pan Grille
Pos
Ro
om
Nu
mb
er
Pro
du
ct /
vers
ion
Hei
gh
t in
mm
Dep
th in
mm
Len
gth
in m
m
Co
nn
ecti
on
sys
tem
Co
up
ling
of
rad
iato
r p
osi
tio
n
Des
ign
(in
terc
on
nec
ted
)
Arr
ang
emen
t
Co
nn
ecti
on
siz
e
Pres
sure
ver
sio
n
Top
gri
lle
Fitt
ing
s
Act
uat
or
Fitt
ing
Pan
co
lou
r
Pan
co
lou
r co
de
Edg
e b
ar c
olo
ur
Top
gri
lle v
ersi
on
Spec
ials
|HOE| |MT| |LAE| |VT| |KHP| |BF| |ANB| |VG| |RG| |DRU| |ABD| |EBT| |STT| |VRS| |FAR1| |FNR1| |RDL| |AUS| |BES|
1 WG 1 KRP91 150 185 1000 2 BB 64 64 10 LR RAL 7016 ELO ELO
2 WG 1 KRP91 92 260 2050 2 33 64 64 10 RR TS1 STT VRS RAL 7016 DKS DKS SBL
RoomInformation on the room in which the radiator will be installed
Ordering information Ordering code
Conservatory WG
Entrance Entrance
Administrative building VG
... ...
NumberNumber of radiators
Ordering informationOrdering code for example
1 radiator 1
2 radiators 2
Product / version
Ordering information Ordering code
Ascotherm KRP91 Natural Convection KRP91
|HOE| - Height BH in mm
Ordering information Ordering code
92 mm 92
120 mm 120
150 mm 150
200 mm 200
|MT| - Depth in mm
Ordering information Ordering code
185 mm 185
210 mm 210
260 mm 260
310 mm 310
360 mm 360
400 mm 400
|LAE| - Length in mm
Ordering information Ordering code
from 1000 mm to 5000 mm 1000 - 5000
|VT| - Flow / return: Connection system
Ordering information Ordering code
2-pipe system (flow and return are separate)
2
Other connection arrangements
Ordering information Ordering code
Coupled on same side in series 75
Special connections 99
|KHP| - Coupling of radiator position
Ordering information Ordering code
Without coupling –
Initial radiator 1
Centred radiator 2
Final radiator 3
|BF| - radiator design
Ordering information Ordering code
Without –
Connected at right end 1
Connected at both ends 2
Connected at left end 3
|ANB| - Flow / return: Arrangement
Ordering information Ordering code
1st digit: pos. flow 2nd digit: pos. return
DB
8 361
|VG| - Flow connection size
Ordering information Ordering code
G 3/4’’ 64
|RG| - Return connection size
Ordering information Ordering code
G 3/4’’ 64
|DRU| - Pressure version in bar (Pa)
Ordering information Ordering code
Standard version: 10 bar (1000 kPa) 10
High-pressure version: 16 bar (1600 kPa) 16
Ascotherm® eco KRP91Further information
104 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Ordering process
Furt
her
info
r-m
atio
n
|ABD| - Top grille
Ordering information Ordering code
Without –
Standard version: Aluminium linear grille LR
Aluminium roll-up grille RR
|EBT| - Fittings
Ordering information Ordering code
Without impact sound insulation –
With impact sound insulation TS1
|STT| - Actuator
Ordering information Ordering code
Without actuator –
With actuator STT
|VRS| - Fitting
Ordering information Ordering code
Without Fitting –
With Fitting VRS
Floor pan |FAR1| - Surface: Colour
Ordering information Ordering code
RAL RAL
|FNR1| - Surface: Colour code
Ordering information Ordering code
Anthracite grey 7016
Edge bar |RDL| - Edge bar colour
Ordering information Ordering code
Anodised ELO
Bronze BRO
Brass MES
Dark silver DKS
black SWZ
Stainless steel EDS
Pan colour FAR1
Grille colour FAR2
Top grilles |AUS| - Top grille version Ordering information Ordering code
Anodised ELO
Bronze BRO
Brass MES
Dark silver DKS
black SWZ
Finished LAC
Stainless steel 1) EDS
Type of wood: beech 1) HBU
Type of wood: oak 1) HEI
Type of wood: ash 1) HES1) This version is only possible with roll-up grille.
|BES| - Specials
Ordering information Ordering code
Mitre / column 75
Single mitre 76
Double mitre 77
Special height SBH
Special length SBL
Special depth SBT
= Standard version, instead of value, it is also possible to insert "-"
Ascotherm® eco KRN92Further information
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 105
Ordering process
Furt
her
info
rmat
ion
Product Flow/return Floor pan Grile
Pos
Ro
om
Nu
mb
er
Pro
du
ct /
vers
ion
Hei
gh
t in
mm
Dep
th in
mm
Len
gth
in m
m
Co
nn
ecti
on
sys
tem
Co
up
ling
of
rad
iato
r p
osi
tio
n
Des
ign
(in
terc
on
nec
ted
)
Arr
ang
emen
t
Nu
mb
er o
f ai
r co
nn
ec-
tio
ns
Air
co
nn
ecti
on
arr
an-
gem
ent
Air
co
nn
ecti
on
siz
e
Co
nn
ecti
on
siz
e
Pres
sure
ver
sio
n
Top
gri
lle
Fitt
ing
s
Act
uat
or
Fitt
ing
Pan
co
lou
r
Pan
co
lou
r co
de
Edg
e b
ar c
olo
ur
Top
gri
lle v
ersi
on
Spec
ials
|HOE| |MT| |LAE| |VT| |KHP| |BF| |ANB| |LAZ| |LAP| |LAG| |VG| |RG| |DRU| |ABD| |EBT| |STT| |VRS| |FAR1| |FNR1| |RDL| |AUS| |BES|
1 HK2 2 KRN92 110 310 2750 2 11 1 F 63 64 64 10 LR RAL 7016 ELO ELO
2 HK2 1 KRN92 200 185 2000 2 BB 1 F 100 64 64 10 RR STT VRS RAL 7016 SWZ SWZ
RoomInformation on the room in which the radiator will be installed
Ordering information Ordering code
Conservatory WG
Administrative building VG
... ...
NumberNumber of radiators
Ordering information Ordering code
1 radiator 1
2 radiators 2
Product / version
Ordering information Ordering code
Ascotherm KRN92 Natural convection with additional air connection
KRN92
|HOE| - Height BH in mm
Ordering information Ordering code
110 mm 110
150 mm 150
200 mm 200
|MT| - Depth in mm
Ordering information Ordering code
185 mm 185
210 mm 210
260 mm 260
310 mm 310
360 mm 360
400 mm 400
|LAE| - Length in mm
Ordering information Ordering code
from 1000 mm to 5000 mm 1000 - 5000
|VT| - Flow / return: Connection system
Ordering information Ordering code
2-pipe system (flow and return are separate)
2
Other connection arrangements
Ordering information Ordering code
Coupled on same side in series 75
Special connections 99
|KHP| - Coupling of radiator position
Ordering information Ordering code
Without coupling –
Initial radiator 1
Centred radiator 2
Final radiator 3
|BF| - radiator design
Ordering information Ordering code
Without –
Connected at right end 1
Connected at both ends 2
Connected at left end 3
|ANB| - Flow / return: Arrangement
Ordering information Ordering code
1st digit: pos. flow 2nd digit: pos. return
DB
8 361
|LAZ| - Number of air connections
Ordering information Ordering code
One 1
Select 2 - 10 2 - 10
|LAP| - Air connection arrangement
Ordering information Ordering code
Air connection F
Special connection according to drawing SON
Ascotherm® eco KRN92Further information
106 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Ordering process
Furt
her
info
r-m
atio
n
|LAG| - Air connection size
Ordering information Ordering code
Connection 63 mm 63
Connection 80 mm 80
Connection 100 mm 100
Connection 125 mm 125
• Connection size depends on height
|VG| - Flow connection size
Ordering information Ordering code
G 3/4’’ 64
|RG| - Return connection size
Ordering information Ordering code
G 3/4’’ 64
|DRU| - Pressure version in bar (Pa)
Ordering information Ordering code
Standard version: 10 bar (1000 kPa) 10
High-pressure version: 16 bar (1600 kPa) 16
|ABD| - Top grille
Ordering information Ordering code
Without –
Standard version: Aluminium linear grille LR
Aluminium roll-up grille RR
|EBT| - Fittings
Ordering information Ordering code
Without impact sound insulation –
With impact sound insulation TS1
|STT| - Actuator
Ordering information Ordering code
Without actuator –
With actuator STT
|VRS| - Fitting
Ordering information Ordering code
Without Fitting –
With Fitting VRS
Floor pan |FAR1| - Surface: Colour
Ordering information Ordering code
RAL RAL
|FNR1| - Surface: Colour code
Ordering information Ordering code
Anthracite grey 7016
Edge bar |RDL| - Edge bar colour
Ordering information Ordering code
Anodised ELO
Bronze BRO
Brass MES
Dark silver DKS
black SWZ
Stainless steel EDS
Pan colour FAR1
Grille colour FAR2
Top grilles |AUS| - Top grille version Ordering information Ordering code
Anodised ELO
Bronze BRO
Brass MES
Dark silver DKS
black SWZ
Finished LAC
Stainless steel 1) EDS
Type of wood: beech 1) HBU
Type of wood: oak 1) HEI
Type of wood: ash 1) HES1) This version is only possible with roll-up grille.
|BES| - Specials
Ordering information Ordering code
Mitre / column 75
Single mitre 76
Double mitre 77
Special height SBH
Special length SBL
Special depth SBT
= Standard version, instead of value, it is also possible to insert "-"
Ascotherm® eco KRN81Further information
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 107
Ordering process
Furt
her
info
rmat
ion
Product Flow/return Floor pan Grille
Pos
Ro
om
Nu
mb
er
Pro
du
ct /
vers
ion
Hei
gh
t in
mm
Dep
th in
mm
Len
gth
in m
m
Co
nn
ecti
on
sys
tem
Co
up
ling
of
rad
iato
r p
osi
tio
n
Des
ign
(in
terc
on
nec
ted
)
Arr
ang
emen
t
Co
nn
ecti
on
siz
e
Pres
sure
ver
sio
n
Top
gri
lle
Fitt
ing
s
Filt
er f
leec
e
Act
uat
or
Fitt
ing
Co
ntr
ol s
yste
m
Bu
ildin
g m
anag
emen
t sy
stem
Pan
co
lou
r
Pan
co
lou
r co
de
Top
gri
lle v
ersi
on
Edg
e b
ar c
olo
ur
Spec
ials
|HOE| |MT| |LAE| |VT| |KHP| |BF| |ANB| |VG| |RG| |DRU| |ABD| |EBT| |FVL| |STT| |VRS| |RLT| |GLT| |FAR1| |FNR1| |AUS| |RDL| |BES|
1 R01 1 KRN81 110 310 1250 2 BB 64 64 10 RR TS1 FV RLT RAL 7016 HEI ELO
2 R01 1 KRN81 110 260 3000 2 33 64 64 10 LR STT VRS RLT RAL 7016 ELO ELO
RoomInformation on the room in which the radiator will be installed
Ordering information Ordering code
Conservatory WG
Administrative building VG
... ...
NumberNumber of radiators
Ordering information Ordering code
1 radiator 1
2 radiators 2
Product / version
Ordering information Ordering code
Ascotherm KRN81 Forced convection with cross-flow fan
KRN81
|HOE| - Height BH in mm
Ordering information Ordering code
110 mm 110
|MT| - Depth in mm
Ordering information Ordering code
185 mm 185
210 mm 210
260 mm 260
310 mm 310
360 mm 360
|LAE| - Length in mm
Ordering information Ordering code
from 1250 mm to 4000 mm 1250 - 4000
|VT| - Flow / return: Connection system
Ordering information Ordering code
2-pipe system (flow and return are separate)
2
Other connection arrangements
Ordering information Ordering code
Coupled on same side in series 75
Special connections 99
|KHP| - Coupling of radiator position
Ordering information Ordering code
Without coupling –
Initial radiator 1
Centred radiator 2
Final radiator 3
|BF| - radiator design
Ordering information Ordering code
Without –
Connected at right end 1
Connected at both ends 2
Connected at left end 3
|ANB| - Flow / return: Arrangement
Ordering information Ordering code
1st digit: pos. flow 2nd digit: pos. return
DB
8 361
|VG| - Flow connection size
Ordering information Ordering code
G 3/4’’ 64
|RG| - Return connection size
Ordering information Ordering code
G 3/4’’ 64
|DRU| - Pressure version in bar (Pa)
Ordering information Ordering code
Standard version: 10 bar (1000 kPa) 10
High-pressure version: 16 bar (1600 kPa) 16
Ascotherm® eco KRN81Further information
108 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Ordering process
Furt
her
info
r-m
atio
n
|ABD| - Top grille
Ordering information Ordering code
Without –
Standard version: Aluminium linear grille LR
Aluminium roll-up grille RR
|EBT| - Fittings
Ordering information Ordering code
Without impact sound insulation –
With impact sound insulation TS1
|FVL| - Filter fleece
Ordering information Ordering code
Without filter fleece –
With filter fleece FV
|STT| - Actuator
Ordering information Ordering code
Without actuator –
With actuator STT
|VRS| - Fitting
Ordering information Ordering code
Without Fitting –
With Fitting VRS
|RLT| - Control system
Ordering information Ordering code
Without control system –
With control system RLT
|GLT| - Building management system
Ordering information Ordering code
Without –
KNX card KNX
LON card LON
Floor pan |FAR1| - Surface: Colour
Ordering information Ordering code
RAL RAL
|FNR1| - Surface: Colour code
Ordering information Ordering code
Anthracite grey 7016
Edge bar |RDL| - Edge bar colour
Ordering information Ordering code
Anodised ELO
Bronze BRO
Brass MES
Dark silver DKS
black SWZ
Stainless steel EDS
Pan colour FAR1
Grille colour FAR2
Top grilles |AUS| - Top grille version Ordering information Ordering code
Anodised ELO
Bronze BRO
Brass MES
Dark silver DKS
black SWZ
Finished LAC
Stainless steel 1) EDS
Type of wood: beech 1) HBU
Type of wood: oak 1) HEI
Type of wood: ash 1) HES1) This version is only possible with roll-up grille.
|BES| - Specials
Ordering information Ordering code
Mitre / column 75
Single mitre 76
Double mitre 77
Special height SBH
Special length SBL
Special depth SBT
= Standard version, instead of value, it is also possible to insert "-"
Ascotherm® eco KC281Further information
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 109
Ordering process
Furt
her
info
rmat
ion
Product Flow/return Floor pan Grille
Pos
Ro
om
Nu
mb
er
Pro
du
ct /
vers
ion
Hei
gh
t in
mm
Dep
th in
mm
Len
gth
in m
m
Co
nn
ecti
on
sys
tem
Co
up
ling
of
rad
iato
r p
osi
tio
n
Des
ign
(in
terc
on
nec
ted
)
Hea
tin
g /
coo
ling
arr
an-
gem
ent
Co
nn
ecti
on
siz
e
Pres
sure
ver
sio
n
Top
gri
lle
Fitt
ing
s
Filt
er f
leec
e
Co
nd
ensa
te p
um
p
Act
uat
or
Fitt
ing
Co
ntr
ol s
yste
m
Bu
ildin
g m
anag
emen
t sy
stem
Pan
co
lou
r
Pan
co
lou
r co
de
Edg
e b
ar c
olo
ur
Top
gri
lle v
ersi
on
Spec
ials
|HOE| |MT| |LAE| |VT| |KHP| |BF| |ANB| |VG| |RG| |DRU| |ABD| |EBT| |FVL| |PUM| |STT| |VRS| |RLT| |GLT| |FAR1| |FNR1| |RDL| |AUS| |BES|
1 R02 2KC
281130 310 1250 2 BB 64 64 10 RR TS1 RAL 7016 ELO ELO
RoomInformation on the room in which the radiator will be installed
Ordering information Ordering code
Conservatory WG
Entrance Entrance
Administrative building VG
... ...
NumberNumber of radiators
Ordering information Ordering code
1 radiator 1
2 radiators 2
Product / version
Ordering information Ordering code
Ascotherm KC281 heating and cooling in 2-pipe system
KC 281
|HOE| - Height BH in mm
Ordering information Ordering code
130 mm 130
155 mm 155
|MT| - Depth in mm
Ordering information Ordering code
310 mm 310
360 mm 360
|LAE| - Length in mm
Ordering information Ordering code
1250 mm 1250
2000 mm 2000
2750 mm 2750
|VT| - Flow / return: Connection system
Ordering information Ordering code
2-pipe system (flow and return are separate)
2
Other connection arrangements
Ordering information Ordering code
Coupled on same side in series 75
Special connections 99
|KHP| - Coupling of radiator position
Ordering information Ordering code
Without coupling –
Initial radiator 1
Centred radiator 2
Final radiator 3
|BF| - radiator design
Ordering information Ordering code
Without –
Connected at right end 1
Connected at both ends 2
Connected at left end 3
|ANB| - Flow / return: Arrangement
Ordering information Ordering code
1st digit: pos. flow 2nd digit: pos. return
DB
8 361
|VG| - Flow connection size
Ordering information Ordering code
G 3/4’’ 64
|RG| - Return connection size
Ordering information Ordering code
G 3/4’’ 64
|DRU| - Pressure version in bar (Pa)
Ordering information Ordering code
Standard version: 10 bar (1000 kPa) 10
High-pressure version: 16 bar (1600 kPa) 16
Ascotherm® eco KC281Further information
110 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Ordering process
Furt
her
info
r-m
atio
n
|ABD| - Top grille
Ordering information Ordering code
Without –
Aluminium linear grille LR
Standard version: Aluminium roll-up grille RR
|EBT| - Fittings
Ordering information Ordering code
Without impact sound insulation –
With impact sound insulation TS1
|FVL| - Filter fleece
Ordering information Ordering code
Without filter fleece –
With filter fleece FV
|PUM| - Condensate pump
Ordering information Ordering code
Without condensate pump –
With condensate pump PUM
|STT| - Actuator
Ordering information Ordering code
Without actuator –
With actuator STT
|VRS| - Fitting
Ordering information Ordering code
Without Fitting –
With Fitting VRS
|RLT| - Control system
Ordering information Ordering code
Without control system –
With control system RLT
|GLT| - Building management system
Ordering information Ordering code
Without –
KNX card KNX
LON card LON
Floor pan |FAR1| - Surface: Colour
Ordering information Ordering code
RAL RAL
|FNR1| - Surface: Colour code
Ordering information Ordering code
Anthracite grey 7016
Edge bar |RDL| - Edge bar colour
Ordering information Ordering code
Anodised ELO
Bronze BRO
Brass MES
Dark silver DKS
black SWZ
Stainless steel EDS
Pan colour FAR1
Grille colour FAR2
Top grilles |AUS| - Top grille version Ordering information Ordering code
Anodised ELO
Bronze BRO
Brass MES
Dark silver DKS
black SWZ
Finished LAC
Stainless steel 1) EDS
Type of wood: beech 1) HBU
Type of wood: oak 1) HEI
Type of wood: ash 1) HES1) This version is only possible with roll-up grille.
|BES| - Specials
Ordering information Ordering code
Mitre / column 75
Single mitre 76
Double mitre 77
Special height SBH
Special length SBL
Special depth SBT
= Standard version, instead of value, it is also possible to insert "-"
Ascotherm® eco KC481Further information
Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 111
Ordering process
Furt
her
info
rmat
ion
Product Flow/return Floor pan Grille
Pos
Ro
om
Nu
mb
er
Pro
du
ct /
vers
ion
Hei
gh
t in
mm
Dep
th in
mm
Len
gth
in m
m
Co
nn
ecti
on
sys
tem
Co
up
ling
of
rad
iato
r p
osi
tio
n
Des
ign
(in
terc
on
nec
ted
)
Arr
ang
emen
t h
eati
ng
Arr
ang
emen
t co
olin
g
Co
nn
ecti
on
siz
e h
eati
ng
Co
nn
ecti
on
siz
e co
olin
g
Pres
sure
ver
sio
n
Top
gri
lle
Fitt
ing
s
Filt
er f
leec
e
Co
nd
ensa
te p
um
p
Act
uat
or
Fitt
ing
Co
ntr
ol s
yste
m
Bu
ildin
g m
anag
emen
t sy
stem
Pan
co
lou
r
Pan
co
lou
r co
de
Edg
e b
ar c
olo
ur
Top
gri
lle v
ersi
on
Spec
ials
|HOE| |MT| |LAE| |VT| |KHP| |BF| |ANB| |ANK| |VG| |RG| |VGK| |RGK| |DRU| |ABD| |EBT| |FVL| |PUM| |STT| |VRS| |RLT| |GLT| |FAR1| |FNR1| |RDL| |AUS| |BES|
1 LW 2 KC 481 155 330 2750 4 11 33 64 64 64 64 10 RR TS1 FV STT VRS RLT RAL 7016 EDS EDS
RoomInformation on the room in which the radiator will be installed
Ordering information Ordering code
Conservatory WG
Entrance Entrance
Administrative building VG
... ...
NumberNumber of radiators
Ordering information Ordering code
1 radiator 1
2 radiators 2
Product / version
Ordering information Ordering code
Ascotherm KC481 heating and cooling in 4-conductor system
KC 481
|HOE| - Height BH in mm
Ordering information Ordering code
130 mm 130
155 mm 155
|MT| - Depth in mm
Ordering information Ordering code
330 mm 330
360 mm 360
|LAE| - Length in mm
Ordering information Ordering code
1250 mm 1250
2000 mm 2000
2750 mm 2750
|VT| - Flow / return: Connection system
Ordering information Ordering code
4-pipe system (heating flow and return, cooling flow and return are separate)
4
Other connection arrangements
Ordering information Ordering code
Coupled on same side in series 75
Special connections 99
|KHP| - Coupling of radiator position
Ordering information Ordering code
Without coupling –
Initial radiator 1
Centred radiator 2
Final radiator 3
|BF| - radiator design
Ordering information Ordering code
Without –
Connected at right end 1
Connected at both ends 2
Connected at left end 3
|ANB| - Flow / return: Heating arrangement
Ordering information Ordering code
1st digit: pos. flow 2nd digit: pos. return
DB
8 361
|ANK| - Flow / return: Cooling arrangement
Ordering information Ordering code
1st digit: pos. flow 2nd digit: pos. return
DB
8 361
|VG| - Flow connection size
Ordering information Ordering code
G 3/4’’ 64
|RG| - Return connection size
Ordering information Ordering code
G 3/4’’ 64
Ascotherm® eco KC481Further information
112 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.
Ordering process
Furt
her
info
r-m
atio
n
|VGK| - Flow connection size
Ordering information Ordering code
G 3/4’’ 64
|RGK| - Return connection size
Ordering information Ordering code
G 3/4’’ 64
|DRU| - Pressure version in bar (Pa)
Ordering information Ordering code
Standard version: 10 bar (1000 kPa) 10
High-pressure version: 16 bar (1600 kPa) 16
|ABD| - Top grille
Ordering information Ordering code
Without –
Aluminium linear grille LR
Standard version: Aluminium roll-up grille RR
|EBT| - Fittings
Ordering information Ordering code
Without impact sound insulation –
With impact sound insulation TS1
|FVL| - Filter fleece
Ordering information Ordering code
Without filter fleece –
With filter fleece FV
|PUM| - Condensate pump
Ordering information Ordering code
Without condensate pump –
With condensate pump PUM
|STT| - Actuator
Ordering information Ordering code
Without actuator –
With actuator STT
|VRS| - Fitting
Ordering information Ordering code
Without Fitting –
With Fitting VRS
|RLT| - Control system
Ordering information Ordering code
Without control system –
With control system RLT
|GLT| - Building management system
Ordering information Ordering code
Without –
KNX card KNX
LON card LON
Floor pan |FAR1| - Surface: Colour
Ordering information Ordering code
RAL RAL
|FNR1| - Surface: Colour code
Ordering information Ordering code
Anthracite grey 7016
Edge bar |RDL| - Edge bar colour
Ordering information Ordering code
Anodised ELO
Bronze BRO
Brass MES
Dark silver DKS
black SWZ
Stainless steel EDS
Pan colour FAR1
Grille colour FAR2
Top grilles |AUS| - Top grille version Ordering information Ordering code
Anodised ELO
Bronze BRO
Brass MES
Dark silver DKS
black SWZ
Finished LAC
Stainless steel 1) EDS
Type of wood: beech 1) HBU
Type of wood: oak 1) HEI
Type of wood: ash 1) HES1) This version is only possible with roll-up grille.
|BES| - Specials
Ordering information Ordering code
Mitre / column 75
Single mitre 76
Double mitre 77
Special height SBH
Special length SBL
Special depth SBT
= Standard version, instead of value, it is also possible to insert "-"
Prodcut Flow/return Floor pan Grille
Pos
Ro
om
Nu
mb
er
Pro
du
ct /
vers
ion
Hei
gh
t in
mm
Dep
th in
mm
Len
gth
in m
m
Co
nn
ecti
on
sys
tem
Co
up
ling
of
rad
ia-
tor
po
siti
on
Des
ign
(in
terc
on
-n
ecte
d)
Arr
ang
emen
t h
eati
ng
Arr
ang
emen
t co
olin
g
Nu
mb
er o
f ai
r
con
nec
tio
ns
Air
co
nn
ecti
on
ar
ran
gem
ent
Air
co
nn
ecti
on
siz
e
Pres
sure
ver
sio
n
Top
gri
lle
Fitt
ing
s
Filt
er f
leec
e
Co
nd
ensa
te p
um
p
Act
uat
or
Fitt
ing
Co
ntr
ol s
yste
m
Bu
ildin
g m
anag
e-m
ent
syst
em
Pan
co
lou
r
Pan
co
lou
r co
de
Edg
e b
ar c
olo
ur
Top
gri
lle v
ersi
on
Spec
ials
|HOE| |MT| |LAE| |VT| |KHP| |BF| |ANB| |ANK| |LAZ| |LAP| |LAG| |DRU| |ABD| |EBT| |FVL| |PUM| |STT| |VRS| |RLT| |GLT| |FAR1| |FNR1| |RDL| |AUS| |BES|
1
2
3
4
5
6
7
8
9
10
Ascotherm® ecoOrder Form
Ordering process
Customer Ordered by
Object Desired delivery date
Address Address Address
Postcode / city
Postcode / city
Postcode / city
Tel. / Fax Tel. / Fax Tel. / Fax