AS/NZS 1768:2007 Australian/New Zealand Standard Lightning protection AS/NZS 1768:2007 Accessed by UNIVERSITY OF TASMANIA on 11 Sep 2009
Transcript
Page 1: ASNZS 1768-2007

AS/NZS 1768:2007

Australian/New Zealand Standard™

Lightning protection

AS

/NZ

S 1

76

8:2

00

7

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 2: ASNZS 1768-2007

AS/NZS 1768:2007

This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee EL-024, Protection Against Lightning. It was approved on behalf of the Council of Standards Australia on 13 September 2006 and on behalf of the Council of Standards New Zealand on 6 October 2006. This Standard was published on 10 January 2007.

The following are represented on Committee EL-024:

Association of Consulting Engineers Australia

Australasian Corrosion Association

Australasian Railway Association

Australian Chamber of Commerce and Industry

Australian Electrical and Electronic Manufacturers Association

Australian Institute of Petroleum Ltd

Bureau of Meteorology

CSIRO Industrial Physics

Department of Defence (Australia)

Department of Natural Resources and Mines (QLD)

Department of Primary Industries, Mine Safety (NSW)

Energy Networks Association

Engineers Australia

ITU NSG5

Master Builders Australia

Ministry of Economic Development (New Zealand)

National Electrical and Communications Association

Telstra Corporation Limited

The University of Queensland

Transpower New Zealand

UniQuest

Keeping Standards up-to-date

Standards are living documents which reflect progress in science, technology and systems. To maintain their currency, all Standards are periodically reviewed, and new editions are published. Between editions, amendments may be issued. Standards may also be withdrawn. It is important that readers assure themselves they are using a current Standard, which should include any amendments which may have been published since the Standard was purchased.

Detailed information about joint Australian/New Zealand Standards can be found by visiting the Standards Web Shop at www.standards.com.au or Standards New Zealand web site at www.standards.co.nz and looking up the relevant Standard in the on-line catalogue.

Alternatively, both organizations publish an annual printed Catalogue with full details of all current Standards. For more frequent listings or notification of revisions, amendments and withdrawals, Standards Australia and Standards New Zealand offer a number of update options. For information about these services, users should contact their respective national Standards organization.

We also welcome suggestions for improvement in our Standards, and especially encourage readers to notify us immediately of any apparent inaccuracies or ambiguities. Please address your comments to the Chief Executive of either Standards Australia or Standards New Zealand at the address shown on the back cover.

This Standard was issued in draft form for comment as DR 06132. A

cces

sed

by U

NIV

ER

SIT

Y O

F TA

SM

AN

IA o

n 11

Sep

200

9

Page 3: ASNZS 1768-2007

AS/NZS 1768:2007

Australian/New Zealand Standard™

Lightning protection

Originated in Australia as MC1—1969. Originated in New Zealand as NZS/AS 1768:1991. Previous edition AS/NZS 1768(Int):2003. This edition AS/NZS 1768:2007.

COPYRIGHT

© Standards Australia/Standards New Zealand

All rights are reserved. No part of this work may be reproduced or copied in any form or by

any means, electronic or mechanical, including photocopying, without the written

permission of the publisher.

Jointly published by Standards Australia, GPO Box 476, Sydney, NSW 2001 and Standards

New Zealand, Private Bag 2439, Wellington 6020

ISBN 0 7337 7967 0

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 4: ASNZS 1768-2007

AS/NZS 1768:2007 2

PREFACE

This Standard was prepared by the Joint Standards Australia/Standards New Zealand

Committee EL-024, Protection against Lightning, to supersede AS/NZS 1768(Int):2003,

Lightning protection.

This Standard is intended to provide authoritative guidance on the principles and practices

of lightning protection for a wide range of structures and systems. It is not intended for

mandatory application but, if called up in a contractual situation, compliance with this

Standard requires compliance with all relevant clauses of the Standard such that the level of

protection will be sufficient to achieve a tolerable level of risk as determined by the risk

calculation.

In general, it is not economically possible to provide total protection against all the possible

damaging effects of lightning, but the recommendations in this Standard will reduce the

probability of damage to a calculated acceptable level, and will minimize any lightning

damage that does occur. Guidance is given on methods of enhancing the level of protection

against lightning damage, if this is required in a particular situation.

Where a new structure is to be erected, the matter of lightning protection should be

considered in the planning stage, as the necessary measures can often be affected in the

architectural features without detracting from the appearance of the building. In addition to

the aesthetic considerations, it is usually less expensive to install a lightning protection

system during construction than afterwards.

The decision to provide lightning protection may be taken without carrying out a risk

assessment or regardless of the outcome of any risk assessment, for example, where there is

a desire that there be no avoidable risk. Any decision not to provide lightning protection

should only be made after considering the advice provided in this Standard. Where doubt

exists as to the need for lightning protection, further advice should be sought from a

lightning protection designer or installer.

Unless it has been specified that lightning protection must be provided, the first decision to

make is whether the lightning protection is needed. Section 2 provides guidance to assist in

this decision. Section 3 provides advice on the protection of persons from lightning, mainly

relating to the behaviour of persons when not inside substantial buildings. Once a decision

is made that lightning protection is necessary, Section 4 provides details on interception

lightning protection for the building or structure. This includes information on the size,

material, and form of conductors, the positioning of air terminals and downconductors, and

the requirements for earth terminations. Persons and equipment within buildings can be at

risk from the indirect effects of lightning and Section 5 gives recommendations for the

protection of persons and equipment within buildings from the effects of lightning.

Section 6 describes methods of lightning protection of various items not covered in earlier

sections, such as communications antennas, chimneys, boats, fences, and trees. A clause is

included on methods for protecting domestic dwellings and assorted structures in public

places, where a complete protection system may not be justified, but some protection is

considered desirable.

Section 7 sets out recommendations for the protection of structures with explosive or

highly-flammable contents. Section 8 gives advice on precautions to be taken during

installation, inspecting, testing, and maintaining lightning protection systems.

A number of appendices are included that provide additional information and advice. The

appendices form an integral part of this Standard unless specifically stated otherwise. i.e.

appendices identified as ‘informative’ only provide supportive or background information

and are therefore not an integral part of this Standard.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 5: ASNZS 1768-2007

3 AS/NZS 1768:2007

CONTENTS

Page

SECTION 1 SCOPE AND GENERAL

1.1 SCOPE ........................................................................................................................ 5

1.2 APPLICATION ........................................................................................................... 5

1.3 INTRODUCTION ....................................................................................................... 5

1.4 REFERENCED DOCUMENTS .................................................................................. 6

1.5 DEFINITIONS ............................................................................................................ 6

SECTION 2 ASSESSMENT AND MANAGEMENT OF RISK DUE TO LIGHTNING —

ANALYSIS OF NEED FOR PROTECTION

2.1 INTRODUCTION ..................................................................................................... 11

2.2 SCOPE OF SECTION ............................................................................................... 11

2.3 CONCEPT OF RISK ................................................................................................. 12

2.4 DAMAGE DUE TO LIGHTNING ............................................................................ 13

2.5 RISKS DUE TO LIGHTNING .................................................................................. 17

2.6 PROCEDURE FOR RISK ASSESSMENT AND MANAGEMENT ......................... 21

2.7 RISK MANAGEMENT CALCULATION TOOL..................................................... 23

SECTION 3 PRECAUTIONS FOR PERSONAL SAFETY

3.1 SCOPE OF SECTION ............................................................................................... 28

3.2 NEED FOR PERSONAL PROTECTION.................................................................. 28

3.3 PERSONAL CONDUCT........................................................................................... 29

3.4 EFFECT ON PERSONS AND TREATMENT FOR INJURY BY LIGHTNING ...... 31

SECTION 4 PROTECTION OF STRUCTURES

4.1 SCOPE OF SECTION ............................................................................................... 32

4.2 PROTECTION LEVEL ............................................................................................. 32

4.3 LPS DESIGN RULES ............................................................................................... 32

4.4 ZONES OF PROTECTION FOR LIGHTING INTERCEPTION .............................. 34

4.5 METHODS OF PROTECTION................................................................................. 42

4.6 MATTERS TO BE CONSIDERED WHEN PLANNING PROTECTION ................ 44

4.7 MATERIALS ............................................................................................................ 47

4.8 FORM AND SIZE OF CONDUCTORS.................................................................... 51

4.9 JOINTS...................................................................................................................... 52

4.10 FASTENERS............................................................................................................. 52

4.11 AIR TERMINALS..................................................................................................... 53

4.12 DOWNCONDUCTORS ............................................................................................ 55

4.13 TEST LINKS............................................................................................................. 58

4.14 EARTH TERMINATIONS........................................................................................ 58

4.15 EARTHING ELECTRODES..................................................................................... 59

4.16 METAL IN AND ON A STRUCTURE..................................................................... 61

SECTION 5 PROTECTION OF PERSONS AND EQUIPMENT WITHIN BUILDINGS

5.1 SCOPE OF SECTION ............................................................................................... 66

5.2 NEED FOR PROTECTION....................................................................................... 66

5.3 MODES OF ENTRY OF LIGHTNING IMPULSES ................................................. 66

5.4 GENERAL CONSIDERATIONS FOR PROTECTION ............................................ 69

5.5 PROTECTION OF PERSONS WITHIN BUILDINGS ............................................. 70

5.6 PROTECTION OF EQUIPMENT ............................................................................. 73

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 6: ASNZS 1768-2007

AS/NZS 1768:2007 4

Page

SECTION 6 PROTECTION OF MISCELLANEOUS STRUCTURES AND PROPERTY

6.1 SCOPE OF SECTION ............................................................................................... 90

6.2 STRUCTURES WITH ANTENNAS......................................................................... 90

6.3 STRUCTURES NEAR TREES ................................................................................. 90

6.4 PROTECTION OF TREES........................................................................................ 91

6.5 CHIMNEYS, METAL GUY-WIRES OR WIRE ROPES.......................................... 91

6.6 PROTECTION OF MINES ....................................................................................... 92

6.7 PROTECTION OF BOATS....................................................................................... 94

6.8 FENCES .................................................................................................................... 97

6.9 MISCELLANEOUS STRUCTURES ........................................................................ 97

6.10 PROTECTION OF HOUSES AND SMALL BUILDINGS ....................................... 99

6.11 PROTECTION OF METALLIC PIPELINES.......................................................... 100

SECTION 7 PROTECTION OF STRUCTURES WITH EXPLOSIVE OR HIGHLY-

FLAMMABLE CONTENTS

7.1 SCOPE OF SECTION ............................................................................................. 101

7.2 GENERAL CONSIDERATIONS............................................................................ 101

7.3 AREAS OF APPLICATION ................................................................................... 102

7.4 EQUIPMENT APPLICATION................................................................................ 102

7.5 SPECIFIC OCCUPANCIES.................................................................................... 104

SECTION 8 INSTALLATION AND MAINTENANCE PRACTICE

8.1 WORK ON SITE..................................................................................................... 109

8.2 INSPECTION.......................................................................................................... 109

8.3 TESTING ................................................................................................................ 109

8.4 RECORDS............................................................................................................... 110

8.5 MAINTENANCE .................................................................................................... 110

APPENDICES

A EXAMPLES OF LIGHTNING RISK CALCULATIONS ...................................... 111

B THE NATURE OF LIGHTNING AND THE PRINCIPLES OF LIGHTNING

PROTECTION ........................................................................................................ 133

C NOTES ON EARTHING ELECTRODES AND MEASUREMENT OF EARTH

IMPEDANCE.......................................................................................................... 145

D THE CALCULATION OF LIGHTNING DISCHARGE VOLTAGES AND

REQUISITE SEPARATION DISTANCES FOR ISOLATION OF A LIGHTNING

PROTECTION SYSTEM ........................................................................................ 165

E EARTHING AND BONDING ................................................................................ 174

F WAVESHAPES FOR ASSESSING THE SUSCEPTIBILITY OF EQUIPMENT

TO TRANSIENT OVERVOLTAGES DUE TO LIGHTNING ............................... 182

G REFERENCED DOCUMENTS .............................................................................. 186

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 7: ASNZS 1768-2007

5 AS/NZS 1768:2007

COPYRIGHT

STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND

Australian/New Zealand Standard

Lightning protection

S E C T I O N 1 S C O P E A N D G E N E R A L

1.1 SCOPE

This Standard sets out guidelines for the protection of persons and property from hazards

arising from exposure to lightning. The recommendations specifically cover the following

applications:

(a) The protection of persons, both outdoors, where they may be at risk from the direct

effects of a lightning strike, and indoors, where they may be at risk indirectly as a

consequence of lightning currents being conducted into the building.

(b) The protection of a variety of buildings or structures, including those with explosive

or highly-flammable contents, and mines.

(c) The protection of sensitive electronic equipment (e.g. facsimile machines, modems,

computers) from overvoltages resulting from a lightning strike to the building or its

associated services.

The nature of lightning and the principles of lightning protection are discussed and

guidance is given to assist in a determination of whether protective measures should be

taken.

This Standard is applicable to conventional lightning protection systems (LPSs) that

comprise air terminals, downconductors, earth termination networks and surge protective

devices (SPDs). Nothing contained within this Standard either endorses or implies the

endorsement of non-conventional LPSs that comprise air terminals that claim enhanced

performance or downconductors that claim enhanced magnetic screening over conventional

systems.

The performance of such systems is outside the scope of this Standard. Irrespective of

claimed performance, air terminals shall be placed in accordance with Section 4 to comply

with this Standard.

1.2 APPLICATION

This Standard does not override any statutory requirements but may be used in conjunction

with such requirements.

Compliance with the recommendations of this Standard will not necessarily prevent damage

or personal injury due to lightning but will reduce the probability of such damage or injury

occurring.

1.3 INTRODUCTION

Thunderstorms are natural phenomena and there are no proven devices and methods capable

of preventing lightning flashes. Direct and nearby cloud-to-ground lightning discharges can

be hazardous to persons, structures, installations and many other things in or on them.

Consideration should always be given to the application of lightning protection measures.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 8: ASNZS 1768-2007

AS/NZS 1768:2007 6

COPYRIGHT

Realization that it is possible to provide effective protection against lightning began with

Franklin and for over a hundred years national and international manuals and standards

have been developed to provide guidance on the principles and practice of lightning

protection. Until about ten years ago, risk assessment was used to determine if there was a

need to provide lightning protection. However, the modern approach is that of risk

management, which integrates the determination of the need for protection with the

selection of adequate protection measures to reduce the risk to a tolerable level. This

selection takes into account both the efficiency of the measures and the cost of their

provision. In the risk management approach, the lightning threats that create risk are

identified, the frequencies of all risk events are estimated, the consequences of the risk

events are determined, and if these are above a tolerable level of risk, protection measures

are applied to reduce the risk (R) to below the tolerable level (Ra). This involves a choice

from a range of protection level efficiencies for protection against direct (d) strikes to the

structure and decisions about the extent of other measures for protecting low-voltage and

electronic equipment against indirect (i) lightning stresses incident from nearby strikes. In

summary—

R = ∑ Rx = ∑ Rd + ∑ Ri

Rx = Nx Px δx

Px = kx px

R ≤ Ra

where Nx is the frequency of dangerous events, Px is the probability of damage or injury, δx

is the relative amount of damage or injury with any consequential effects, and kx is a

reduction factor associated with the protection measure adopted and which equals 1 in the

absence of protection measures when Px = px .

The lightning protection measures include an LPS for the structure and its occupants,

protection against the lightning electromagnetic pulse (LEMP) caused by direct and nearby

strikes, and transient protection (TP) of incoming services. The LPS for the structure

comprises an air terminal network to intercept the lightning strike, a downconductor system

to conduct the discharge current safely to earth and an earth termination network to

dissipate the current into the earth. The LEMP protection includes a number of measures to

protect sensitive electronic equipment such as the use of a mesh of downconductors to

minimize the internal magnetic field, the selection of lightning protection zones,

equipotential bonding and earthing, and the installation of SPDs. The TP for incoming

services includes the use of isolation devices, the shielding of cables and the installation

and coordination of SPDs.

1.4 REFERENCED DOCUMENTS

The documents referred to in this Standard are listed in Appendix G.

1.5 DEFINITIONS

For the purpose of this Standard, the definitions below apply.

1.5.1 Air terminal

A vertical or horizontal conductor of an LPS, positioned so as to intercept a lightning

discharge, which establishes a zone of protection.

1.5.2 Air terminal network

A network of air terminals and interconnecting conductors, which forms the part of an LPS

that is intended to intercept lightning discharges.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 9: ASNZS 1768-2007

7 AS/NZS 1768:2007

COPYRIGHT

1.5.3 Base conductors

Conductors placed around the perimeter of a structure near ground level interconnected to a

number of earth terminations to distribute the lightning currents amongst them.

1.5.4 Bond (bonding conductor)

A conductor intended to provide electrical connection between the LPS and other

metalwork and between various metal parts of a structure or between earthing systems.

1.5.5 Damage (δ)

Mean relative amount of loss consequent to a specified type of damage due to a lightning

event, when damage factors are not taken into account.

1.5.6 Direct lightning flash

A lightning discharge, composed of one or more strokes, that strikes the structure or its LPS

directly.

1.5.7 Downconductor

A conductor that connects an air terminal network with an earth termination.

1.5.8 Earth impedance (Z)

The electrical impedance of an earthing electrode or structure to earth, derived from the

earth potential rise divided by the impulse current to earth causing that rise. It is a relatively

complex function and depends on—

(a) the resistance component (R) as measured by an earth tester;

(b) the reactance component (X), depending on the circuit path to the general body of

earth; and

(c) a modifying (reducing) time-related component depending on soil ionization caused

by high current and fast rise times.

1.5.9 Earth potential rise (EPR)

The increase in electrical potential of an earthing electrode, body of soil or earthed

structure, with respect to distant earth, caused by the discharge of current to the general

body of earth through the impedance of that earthing electrode or structure.

1.5.10 Earthing boss (terminal lug)

A metal boss specially designed and welded to process plant, storage tanks, or steelwork to

which earthing conductors are attached by means of removable studs or nuts and bolts.

1.5.11 Earthing conductor

The conductor by which the final connection to an earthing electrode is made.

1.5.12 Earthing electrodes (earth rods or ground rods)

Those portions of the earth termination that make direct low resistance electrical contact

with the earth.

1.5.13 Earthing resistance

The resistance of the LPS to the general mass of earth, as measured from a test point.

1.5.14 Earth termination (earth termination network)

That part of an LPS intended to discharge lightning currents into the general mass of the

earth. All parts below the lowest test link in a downconductor are included.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 10: ASNZS 1768-2007

AS/NZS 1768:2007 8

COPYRIGHT

1.5.15 Electricity supply service earthing electrode

An earthing electrode installed for the purposes of providing the connection of the electrical

installation earthing system to the general mass of earth.

1.5.16 Explosive gas atmosphere

A mixture of flammable gas, vapour or mist with air in atmospheric conditions in which,

after ignition, combustion spreads throughout the unconsumed mixture that is between the

upper and lower explosive limits.

NOTE: The term refers exclusively to the danger arising from ignition. Where danger from other

causes such as toxicity, asphyxiation, and radioactivity may arise this is specifically mentioned.

1.5.17 Finial

A term not used in this Standard owing to its confusion with architectural application but

occasionally used elsewhere in other Standards as referring to short vertical air terminals.

1.5.18 Frequency of lightning flashes direct to a service (Nc)

Expected annual number of lightning flashes directly striking an incoming service.

1.5.19 Frequency of lightning flashes direct to a structure (Nd)

Expected annual number of lightning flashes directly striking the structure.

1.5.20 Frequency of lightning flashes to ground near a service (NI)

Expected annual number of lightning flashes striking the ground surface near an incoming

service.

1.5.21 Frequency of lightning flashes to ground near a structure (Nm)

Expected annual number of lightning flashes striking the ground surface near the structure.

1.5.22 Hazardous area

An area where an explosive atmosphere is, or may be expected to be present continuously,

intermittently or due to an abnormal or transient condition (see AS/NZS 2430 series).

1.5.23 Incoming service

A service entering a structure (e.g. electricity supply service lines, telecommunications

service lines or other services).

1.5.24 Indirect lightning flash

A lightning discharge, composed of one or more strokes, that strikes the incoming services

or the ground near the structure or near the incoming services.

1.5.25 Internal installation

An installation or the part of an incoming service that is located inside the structure.

1.5.26 Joint

A mechanical and electrical junction between two or more sections of an LPS.

1.5.27 Lightning flash (lightning discharge)

An electrical discharge in the atmosphere involving one or more electrically charged

regions, most commonly in a cumulonimbus cloud, taking either of the following forms:

(a) Ground flash (earth discharge) A lightning flash in which at least one lightning

discharge channel reaches the ground.

(b) Cloud flash A lightning flash in which the lightning discharge channels do not reach

the earth.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 11: ASNZS 1768-2007

9 AS/NZS 1768:2007

COPYRIGHT

1.5.28 Lightning flash density (Ng)

The number of lightning flashes of the specified type occurring on or over unit area in unit

time. This is commonly expressed as per square kilometre per year (km−2 year

−1). The

ground flash density is the number of ground flashes per unit area and per unit time,

preferably expressed as a long-term (>10 years) average value.

1.5.29 LPS (LPS Type I to IV)

Complete system used to reduce the danger of physical damages and of injuries due to

direct flashes to the structure. It consists of both external and internal LPSs and is defined

as a set of construction rules, based on corresponding protection level.

1.5.30 Lightning protection zone (LPZ)

With respect to the lightning threat, a zone may be defined, inside of which is sensitive

equipment. Extra protection is applied at the zone boundary to minimize the risk of damage

to equipment inside the zone.

1.5.31 Lightning strike

A term used to describe the lightning flash when the attention is centred on the effects of

the flash at the lightning strike attachment point, rather than on the complete lightning

discharge.

1.5.32 Lightning strike attachment point

The point on the ground or on a structure where the lower end of the lightning discharge

channel connects with the ground or structure.

1.5.33 Lightning stroke

A term used to describe an individual current impulse in a complete ground flash.

1.5.34 Loss

Due to lightning strike, the loss can be of human life, loss of service to the public or

economic loss.

1.5.35 Multiple earthed neutral (MEN) system

A system of earthing in which the parts of an electrical installation are connected to the

general mass of earth and in addition are connected within the electrical installation to the

neutral conductor of the supply system.

1.5.36 Partial probability of damage (p)

Probability of a lightning flash causing a specified type of damage to the structure,

depending on one characteristic of the structure or of an incoming service.

1.5.37 Probability of damage (P)

Probability of a lightning flash causing a specified type of damage to the structure. It may

be composed of one or more simple probabilities of damage.

1.5.38 Protection level (I to IV)

Four levels of lightning protection. For each protection level, a set of maximum (sizing

criteria) and minimum (interception criteria) lightning current parameters is fixed, together

with the corresponding rolling sphere radius.

1.5.39 Protection measures

Protection measures taken to reduce the probability of damage. These may include an LPS

on the building, isolation transformers and/or surge protection on incoming services

(primary protection) and internal equipment (secondary protection).

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 12: ASNZS 1768-2007

AS/NZS 1768:2007 10

COPYRIGHT

1.5.40 Resistibility

Ability of equipment to withstand an overvoltage or an overcurrent without damage.

1.5.41 Risk (R)

Probable average annual loss (humans and goods) in a structure due to lightning flashes.

1.5.42 Risk assessment

The process of designing an LPS to achieve a probable frequency of damage and injury. It

is based on determining the likely number of lightning discharges and also estimates the

probability and consequences. A range of protection measures can be selected to reduce the

risk to less than a target value. This process is also known as risk management.

1.5.43 Risk component

Partial risk assessed according to the source of damage and the type of damage.

1.5.44 Side-flash

A discharge occurring between nearby objects or from such objects to the LPS or to earth.

1.5.45 Special damage factors (kn)

Factors affecting the value of the damage δ, with respect to the existing peculiar conditions

in the structure, that may decrease or increase the loss.

1.5.46 Striking distance (ds)

The distance between the tip of the downward leader and the eventual lightning strike

attachment point at the moment of initiation of an upward intercepting streamer.

1.5.47 Structure or object

Any building or construction, process plant, storage tank, tree, or similar, on or in the

ground.

1.5.48 Surge protective device (SPD)

A device that is intended to mitigate surge overvoltages and overcurrents.

1.5.49 Test link

A joint designed and situated so as to enable resistance or continuity measurements to be

made.

1.5.50 Thunderday

A calendar day during which thunder is heard at a given location. Thunderstorm occurrence

at a particular location is usually expressed in terms of the number of calendar days in a

year when thunder was heard at the location, averaged over several years.

1.5.51 Tolerable risk (Ra)

Maximum value of the risk that can be tolerated in the structure to be protected. Also

referred to as acceptable risk, being the maximum value of risk acceptable based on

community expectations.

1.5.52 Zone of protection

The portion of space within which an object or structure is considered to be protected from

a direct strike by an LPS.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 13: ASNZS 1768-2007

11 AS/NZS 1768:2007

COPYRIGHT

S E C T I O N 2 A S S E S S M E N T A N D

M A N A G E M E N T O F R I S K D U E T O L I G H T N I N G

— A N A L Y S I S O F N E E D F O R P R O T E C T I O N

2.1 INTRODUCTION

Cloud-to-ground lightning discharges can be hazardous to structures, people and

installations or equipment in, on or connected to the structure. Lightning can cause damage

to all or part of a structure or to the contents of a structure, especially to electrical and

electronic systems. Consequential effects of lightning damage may extend to the

surroundings of a structure.

To reduce lightning damage and its consequential effects, lightning protection measures

may be required. The need for protection and the level of protection applied should be

considered in terms of the assessment of risk due to lightning, and management of that risk

to an acceptable level.

The approach outlined in this section is based on the principles of the management of risk

due to lightning outlined in initial work by IEC Committee TC 81 on this subject. The

approach has been simplified by reducing the number of variables and options requiring

selection to a minimum (based on assumptions for general conditions in Australia and New

Zealand) and providing a Microsoft®

Excel calculation tool as an integral part of this

Standard.

The Microsoft® Excel calculation tool provides only an estimate of the lightning risk. The

risk assessment calculator is a simplified tool for the more common structure types. For

specialized structures (e.g. telecommunication exchanges, substations), a detailed lightning

risk assessment may be undertaken. This may involve the application of industry specific

Standards. Where other information exists, such as the damage/hazard history of existing

similar structures in the nearby area, then this should be taken into account when deciding

whether or not to install lightning protection and the appropriate level of lightning

protection required. A decision to provide lightning protection may be taken regardless of

the outcome of any risk assessment, for example, where there is a desire that there be no

avoidable risk. In such cases, the required protection level for the structure (Level I, II, III

or IV – as defined in Section 4) should be specified. It may also be important to specify

other protection measures such as SPDs on incoming conductive electrical service lines and

internal equipment. Risk assessment for protection of specific conductive electrical services

may also be undertaken in isolation based on specific Standards and performance criteria.

For telecommunication overvoltages, AS 4262.1 deals with protection of persons,

AS 4262.2 deals with protection of equipment and the ITU-T K series of recommendations

provide requirements for protecting telecommunication networks.

Before any decision is made not to install lightning protection to a structure, consideration

should be given to the factors outlined in other sections of this Standard.

2.2 SCOPE OF SECTION

This Section is applicable to the management of risk caused by lightning discharges to

earth.

The object of this Section is to give a procedure for evaluation of the risk to a structure,

people and installations or equipment in, on or connected to the structure. This evaluation

considers mechanical damage of the structure and contents, damage and failure of

equipment, potential differences causing deaths of people and livestock from step and touch

voltages, and fire damage that may result from the lightning discharge.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 14: ASNZS 1768-2007

AS/NZS 1768:2007 12

COPYRIGHT

The procedure involves the comparison of the evaluated risk to the tolerable or acceptable

limit of the risk and allows for the selection of appropriate protective measures to reduce

the risk to below the tolerable limit.

This Standard does not consider the risk of personal injury when using telecommunication

equipment during a lightning storm.

2.3 CONCEPT OF RISK

2.3.1 General considerations

In this Standard, risk R is defined as the probable annual loss due to lightning. Expressed as

a number, it represents the probability of loss occurring over the period of a year. Thus a

risk of 10-3

represents a chance of 1 in 1000 of a loss occurring during a year.

To increase understanding of the risk concept, some risks associated with everyday living

are provided in Table 2.1. Many human activities imply a judgement that the benefits

outweigh the related risks. Table 2.1 gives a scale of risk of loss of human life associated

with different activities.

TABLE 2.1

COMPARATIVE PROBABILITY OF DEATH FOR AN INDIVIDUAL PER YEAR

OF EXPOSURE (ORDER OF MAGNITUDE ONLY)*

Risk Activity

Chance of occurrence Probability per year

1 in 400 2.5 × 10−3 Smoking (10 cigarettes per day)

1 in 2000 5 × 10−4 All accidents

1 in 8000 1.3 × 10−4 Traffic accidents

1 in 20 000 5 × 10−5 Leukaemia from natural causes

1 in 30 000 3.3 × 10−5 Work in industry, drowning

1 in 100 000 1 × 10−5 Poisoning

1 in 500 000 2 × 10−6 Natural disasters

1 in 1 000 000 1 × 10−6 Rock climbing for 90 s†,

driving 50 miles (80 km) by road†

1 in 2 000 000 5 × 10−7 Being struck by lightning

* The source of this table is BS 6651:1999.

† These risks are conventionally expressed in this form rather than in terms of exposure for a year.

2.3.2 Types of risk due to lightning

The types of risk due to lightning for a particular structure or facility may include one or

more of the following:

(a) R1—risk of loss of human life.

(b) R2—risk of loss of service to the public.

NOTE: Only applicable to structures involved in the provision of public service utilities (e.g.

water, electricity, gas, telecommunications, rail).

(c) R3—risk of loss of cultural heritage.

(d) R4—risk of loss of economic value.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 15: ASNZS 1768-2007

13 AS/NZS 1768:2007

COPYRIGHT

2.3.3 Tolerable values of risk

In order to manage risk, a judgement must be made of what is an acceptable or tolerable

upper limit for the risk.

In relation to human fatalities, various societal risk guidelines or criteria have been

proposed. Generally for a single human fatality, risks of greater than 10–3 per year (i.e.

chance of 1 in 1000 of occurrence in a year) are considered unacceptable. Public money

would normally be spent to try to eliminate (or reduce to a level as low as reasonably

practical) the causes of risks greater than 10–4

per year (i.e. chance of 1 in 10 000 of

occurrence). Risks less than 10–5

per year (i.e. chance of 1 in 100 000 of occurrence) are

generally considered tolerable although public money may still be spent on an education

campaign to reduce those risks regarded as avoidable.

In terms of the risk of various types of losses due to lightning, a value of the tolerable risk,

Ra needs to be specified. For each type of loss due to lightning, Ra represents the tolerable

probability of that loss occurring over the period of a year. Regarding the potential types of

risk due to lightning listed in Clause 2.3.2, typical values of the tolerable or acceptable risk,

Ra are given in Table 2.2.

TABLE 2.2

TYPICAL VALUES OF TOLERABLE RISK, Ra

Type of loss Tolerable risk per year,

Ra

Loss of human life 10−5

Loss of service to the public 10−3

Loss of cultural heritage 10−3

For a loss of economic value, the tolerable risk, Ra may be fixed by the facility owner or

user, often in consultation with the designer of the protection measures, based on economic

or cost/benefit considerations.

For example, at a particular facility, it may be considered that a chance of 1 in 1000 of

economic loss due to lightning occurring over a period of a year is tolerable. Alternatively,

this would mean that it is considered acceptable for such a loss to occur, on average, once

every 1000 years. In such a case the tolerable risk, Ra for loss of economic value would be

set at 10-3

. Similarly, if it were considered acceptable for such a loss to occur, on average,

once every 100 years, Ra for loss of economic value would be set at 10-2

.

2.4 DAMAGE DUE TO LIGHTNING

2.4.1 Sources of damage

The current in the lightning discharge is the potential source of damage. In this Section, the

following sources of damage, relating to the proximity of the lightning strike, are taken into

account (see Table 2.3):

(a) S1—direct strike to the structure.

(b) S2—strike to the ground near the structure.

(c) S3—direct strike to a conductive electrical service line.

(d) S4—strike to ground near a conductive electrical service line.

Conductive electrical service lines include electricity supply service lines (underground or

overhead) and telecommunications service lines.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 16: ASNZS 1768-2007

AS/NZS 1768:2007 14

COPYRIGHT

The number of lightning strikes influencing the structure depends on—

(i) the dimensions and the characteristics of the structure;

(ii) the dimensions and characteristics of the incoming conductive electrical service lines;

(iii) the environment around the structure; and

(iv) the density of lightning strikes in the region where the structure is located.

The greater the height and collection area, the more lightning strikes will influence the

structure. Tall trees and surrounding buildings may shield a structure from lightning strikes.

Incoming conductive electrical service lines add to the lightning collection area as they can

conduct lightning current into the building.

2.4.2 Types of damage

The type of damage that a lightning strike may cause depends on structure or facility

characteristics such as—

(a) type of construction;

(b) contents and application;

(c) incoming conductive electrical service lines; and

(d) measures taken for limiting the risk.

The damage may be limited to a part of the structure or may extend to the whole structure.

Damage may also extend to the surrounding environment (e.g. contamination caused by

consequential chemical spills or radioactive emissions).

Direct strikes to the structure or to incoming conductive electrical service lines may cause

mechanical damage, injury to people and animals and may cause fire and/or explosion.

Indirect strikes as well as direct strikes may cause failure of electrical and electronic

equipment due to overvoltages resulting from coupling of the lightning current.

For practical applications of risk assessment, it is useful to distinguish between three basic

types of damage that can appear as the consequence of a lightning strike. They are as

follows:

(i) D1—Injury to people (shock of living beings) due to step and touch voltages and

side-flash contact.

(ii) D2—Fire, explosion, mechanical destruction, chemical release due to physical effects

of the lightning channel (including dangerous sparking).

(iii) D3—Failure of electrical and electronic systems due to overvoltages.

2.4.3 Consequences of damage (types of loss)

The value amount of damage caused by the consequential effects of lightning depends on

factors such as—

(a) the number of people and the time they are in the facility;

(b) the type and importance of the service provided to the public; and

(c) the value of goods and/or services affected by the damage.

Some special hazard factors also need to be considered. For example, in theatres and halls

there can be a significant risk of panic if a lightning strike causes loss of electricity supply

or other mechanical or fire-related damage. As a result, people may be injured in the panic

to evacuate the building.

Museums and heritage listed buildings have a cultural value. There may be significant loss

of revenue (economic loss) associated with damage to computer centres and communication

nodes. Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 17: ASNZS 1768-2007

15 AS/NZS 1768:2007

COPYRIGHT

For a particular facility or structure, the following consequences of damage due to lightning

or types of loss should be taken into account.

(i) L1—Loss of human life.

(ii) L2—Loss of services to the public.

NOTE: Only applicable to structures involved in the provision of public service utilities (e.g.

water, electricity, gas, telecommunications, rail).

(iii) L3—Loss of cultural heritage.

(iv) L4—Loss of economic value (structure, content and loss of activity).

Table 2.3 illustrates the relationship between the ‘sources of damage’, ‘types of damage’

and ‘types of loss’ selected according to the point of strike.

TABLE 2.3

SOURCES OF DAMAGES (S1, S2, S3, S4), TYPES OF DAMAGES

(D1, D2, D3) AND TYPES OF LOSS (L1, L2, L3, L4)

SELECTED ACCORDING TO THE POINT OF STRIKE

Structure Service

Point of strike Source of

damage Type of

damage

Type of loss Type of

damage

Type of loss

D1 L1, L4 1)

D2 L1, L2, L3, L4 D2 L1 2), L2, L4

S1

D3 L1, L2, L4 D3 L2, L4

S2 D3 L13), L2, L4

D1 L1, L41)

D2 L1, L2, L3, L4 D2 L12), L2, L4

S3

D3 L1, L2, L4 D3 D2, D4

S4 D3 L13), L2, L4 D3 L2, L4

1) In the case of agricultural properties (loss of animals). 2) In the case of pipelines, with no metallic gasket on flanges, conveying explosive fluid. 3) In the case of hospitals and of structures with risk of explosion.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 18: ASNZS 1768-2007

AS/NZS 1768:2007 16

COPYRIGHT

Figure 2.1 illustrates the relationship between the ‘types of loss’, ‘types of damage’ and

‘components of risk’ (discussed in Clause 2.5.1) that can be associated with lightning

discharges to earth.

FIG

UR

E

2.1

L

OS

SE

S,

DA

MA

GE

S A

ND

RIS

K C

OM

PO

NE

NT

S

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 19: ASNZS 1768-2007

17 AS/NZS 1768:2007

COPYRIGHT

2.5 RISKS DUE TO LIGHTNING

2.5.1 Risk components

For each type of loss relevant to the structure or facility, the total risk due to lightning, R,

is the probability of that loss occurring over the period of a year. The total risk, R, is made

up of the sum of a number of risk components associated with the four possible sources of

damage (according to the point of strike) as listed below:

(a) S1 Lightning strikes directly to the structure

These may generate:

(i) Component Rh due to step and touch voltages outside the structure (mainly

around downconductors) causing shock to living beings (D1).

(ii) Component Rs due to mechanical and thermal effects of the lightning current or

by dangerous sparking causing fire, explosion, mechanical and chemical effects

inside the structure (D2).

(iii) Component Rw due to overvoltages on internal installations and incoming

services causing failure of electrical and electronic systems (D3).

(b) S2 Lightning strikes to ground near the structure

These may generate component Rm due to overvoltages on internal installations and

equipment (mainly induced by the magnetic field associated with the lightning

current) causing failure of electrical and electronic systems (D3).

(c) S3 Lightning strikes directly to conductive electrical service lines

These may generate:

(i) Component Rg due to touch overvoltages transmitted through incoming lines

causing shock of living beings inside the structure (D1).

(ii) Component Rc due to mechanical and thermal effects including dangerous

sparking between external installation and metallic parts (generally at the point-

of-entry of the incoming line into the structure) causing fire, explosion,

mechanical and chemical effects on the structure and/or its content (D2).

(iii) Component Re due to overvoltages, transmitted through incoming lines to the

structure, causing failure of electrical and electronic systems (D3).

(d) S4 Lightning strikes to ground near conductive electrical service line conductors

These may generate component Rl due to induced overvoltages, transmitted through

incoming lines to the structure, causing failure of electrical and electronic systems

(D3).

Figure 2.1 illustrates the relationship between the ‘types of loss’, ‘types of damage’ and

‘risk components’ that can be associated with lightning discharges to earth. Table 2.4

summarizes the various risk components and the ways that these can be summed to give the

total risk.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 20: ASNZS 1768-2007

AS/NZS 1768:2007 18

COPYRIGHT

For each type of loss, the total value of the risk due to lightning, R, may be expressed in the

following ways:

(i) With reference to the type of lightning strike—

R = Rd + Ri . . . 2.5.1(1)

where

Rd = Rh + Rs + Rw risk due to direct strikes to the structure

Ri = Rg + Rc + Rm + Re + Rl risk due to indirect strikes to the structure

(including direct and indirect strikes to

conductive electrical service lines)

(ii) With reference to the types of damage—

R = Rt + Rf + Ro . . . 2.5.1(2)

where

Rt = Rh + Rg risk due to shock to living beings (D1)

Rf = Rs + Rc risk due to fire, explosion, mechanical

destruction and chemical release (D2)

Ro = Rw + Rm + Re + Rl risk due to the failure of electrical and

electronic systems due to overvoltages (D3)

2.5.2 Calculation of risk components

Each component of the risk Rx depends on the number of dangerous events Nx, the

probability of damage Px and the damage factor δx. The value of each component of risk Rx

may be calculated using an expression similar to that shown below:

Rx = Nx Px δx

NOTE: Details of the parameters, factors and equations required to calculate each of the risk

components are given in Appendix A.

For each risk component, the damage factor, δx, represents the mean damage and takes into

account the type of damage, its extent, and the consequential effects that may occur as the

result of a lightning strike. Typical values of the damage factors for each type of loss are

given in Appendix A and in the risk management calculation tool.

NOTE: Where specific information is known regarding the function or use of a particular

structure, alternative damage factor values may be selected based on these relations.

The damage factors are related to the structure’s function or use and may be determined

from the following approximate relations below:

Loss of human life (L1)

δx =

t8760

n t

n

× (relative number of victims) . . . 2.5.2(1)

where

n = the number of possible victims from a lightning strike

nt = the expected total number of people associated with the structure

t = the time, in hours per year, for which the people are present in a

dangerous place

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 21: ASNZS 1768-2007

19 AS/NZS 1768:2007

COPYRIGHT

Unacceptable loss of service to the public (L2)

δx =

t8760

n t

n

× (relative amount of possible loss) . . . 2.5.2(2)

where

n = the mean number of users not served

nt = the total number of users served

t = the annual period of loss of service, in hours.

Loss of cultural heritage (L3)

δx =

tc

c

(relative amount of possible loss) . . . 2.5.2(3)

where

c = the insured value of possible loss of goods (monetary amount)

ct = the total insured value of all goods present in the structure

(monetary amount)

Economic loss (L4)

δx =

tc

c

(relative amount of possible loss) . . . 2.5.2(4)

where

c = the mean value of the possible loss of the structure, its contents and

associated activities (monetary amount)

ct = the total value of the structure, its content and associated activities

(monetary amount)

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 22: ASNZS 1768-2007

COPYRIGHT

20 AS/NZS 1768:2007

TA

BL

E

2.

4

PO

SS

IB

LE

RIS

K C

OM

PO

NE

NT

S C

AU

SE

D B

Y D

IF

FE

RE

NT

EF

FE

CT

S

Lig

htn

ing

Dir

ect

Ind

irect

Ca

use

of

da

ma

ge

Ty

pe o

f

da

ma

ge

S1

Str

ike t

o t

he s

tru

ctu

re

S2

Str

ike t

o g

ro

un

d n

ea

r t

he

stru

ctu

re

S3

Str

ike t

o i

nco

min

g c

on

du

cti

ve

ele

ctr

ica

l se

rv

ice l

ine

S4

Str

ike t

o g

ro

un

d n

ea

r

inco

min

g c

on

du

cti

ve

ele

ctr

ica

l se

rv

ice l

ine

D1

Inju

ry o

f

liv

ing

bein

gs

Rh

Co

mp

on

en

t d

ue t

o s

tep

an

d

tou

ch

vo

ltag

es

or

sid

e-f

lash

arc

fro

m E

PR

ou

tsid

e t

he

stru

ctu

re c

au

sin

g s

ho

ck

to

liv

ing

bein

gs

R

g

Co

mp

on

en

t d

ue t

o t

ou

ch

vo

ltag

es

tran

smit

ted

th

rou

gh

in

co

min

g

co

nd

ucti

ve e

lectr

ical

serv

ice

lin

es

cau

sin

g s

ho

ck

to

liv

ing

bein

gs

insi

de t

he s

tru

ctu

re

R

t =

Rh +

Rg

Ris

k d

ue t

o s

ho

ck

to

liv

ing

bein

gs

D2

Ph

ysi

cal

dest

ructi

on

Rs

Co

mp

on

en

t d

ue t

o m

ech

an

ical

an

d t

herm

al

eff

ects

or

dan

gero

us

spark

ing

cau

sin

g

fire

or

ph

ysi

cal

dam

ag

e

R

c

Co

mp

on

en

t d

ue t

o m

ech

an

ical

an

d t

herm

al

eff

ects

or

dan

gero

us

spark

ing

fro

m i

nco

min

g

co

nd

ucti

ve e

lectr

ical

serv

ice

lin

es

(main

ly a

t th

e p

oin

t-o

f-

en

try

to

th

e s

tru

ctu

re)

cau

sin

g

fire

or

ph

ysi

cal

dam

ag

e

R

f =

Rs

+ R

c

Ris

k d

ue t

o f

ire o

r p

hy

sical

dam

ag

e

D3

Fail

ure

of

ele

ctr

ical

an

d

ele

ctr

on

ic

syst

em

s

Rw

Co

mp

on

en

t d

ue t

o

ov

erv

olt

ag

es

on

in

tern

al

inst

all

ati

on

s an

d i

nco

min

g

serv

ices

cau

sin

g f

ail

ure

of

ele

ctr

ical

an

d e

lectr

on

ic

syst

em

s

Rm

Co

mp

on

en

t d

ue t

o

ov

erv

olt

ag

es

on

in

tern

al

inst

all

ati

on

s an

d e

qu

ipm

en

t

(in

du

ced

by

th

e m

ag

neti

c

field

ass

ocia

ted

wit

h t

he

lig

htn

ing

cu

rren

t) c

au

sin

g

fail

ure

of

ele

ctr

ical

an

d

ele

ctr

on

ic s

yst

em

s

Re

Co

mp

on

en

t d

ue t

o o

verv

olt

ag

es

tran

smit

ted

th

rou

gh

in

co

min

g

co

nd

ucti

ve e

lectr

ical

serv

ice

lin

es

to t

he s

tru

ctu

re c

au

sin

g

fail

ure

of

ele

ctr

ical

an

d

ele

ctr

on

ic s

yst

em

s

R1

Co

mp

on

en

t d

ue t

o

ind

uced

ov

erv

olt

ag

es

tran

smit

ted

th

rou

gh

inco

min

g c

on

du

cti

ve

ele

ctr

ical

serv

ice l

ines

cau

sin

g f

ail

ure

of

ele

ctr

ical

an

d e

lectr

on

ic

syst

em

s

Ro =

Rw

+ R

m +

Re +

R1

Ris

k d

ue t

o t

he f

ail

ure

of

ele

ctr

ical

an

d e

lectr

on

ic

syst

em

s fr

om

ov

erv

olt

ag

es

Rd =

Rh +

Rs

+ R

w

Ris

k d

ue t

o d

irect

stri

kes

to

the s

tru

ctu

re

Ri =

Rg +

Rc +

Rm

+ R

e +

R1

Ris

k d

ue t

o i

nd

irect

stri

kes

to t

he s

tru

ctu

re (

inclu

din

g d

irect

an

d i

nd

irect

stri

kes

to t

he

co

nd

ucti

ve e

lectr

ical

serv

ice l

ines)

R =

Rt

+ R

f +

Ro

To

tal

risk

du

e t

o

lig

htn

ing

R =

Rd +

Ri

To

tal

risk

du

e t

o l

igh

tnin

g

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 23: ASNZS 1768-2007

21 AS/NZS 1768:2007

COPYRIGHT

2.6 PROCEDURE FOR RISK ASSESSMENT AND MANAGEMENT

The procedure for risk assessment and the subsequent selection of protection is outlined in

flow chart form in Figure 2.2.

2.6.1 Procedure for risk assessment

The procedure for the assessment of the risk requires:

(a) Identification of the structure or facility to be protected.

This involves defining the extent of the facility or structure being assessed. In most

cases the structure or facility will be a stand-alone building. The structure may

encompass a building and its associated outbuildings or equipment supports.

Under certain conditions, a facility that is a part of a building may be considered as

‘the structure’ for risk assessment purposes. An example of this might be a

communications installation at the top of an office building. This segregation of a part

of a building is only valid under the following conditions:

(i) There is no risk of explosion in the remainder of the building.

(ii) Suitable fire barriers exist around the structure being considered (fire rating of

not less than 120 min).

(iii) Overvoltage (SPD) protection is provided on all conductive electrical service

lines at their point-of-entry to the structure being considered.

(b) Determination of all the relevant physical, environmental and service installation

factors applicable to the structure.

(c) Identification of all the types of loss relevant for the structure or facility.

For most structures, only L1 and L4 will need to be considered. L3 will apply to

museums, galleries, libraries and heritage listed buildings while L2 applies to

structures involved in the provision of public service utilities such as water, gas,

electricity and telecommunications.

(d) For each type of loss relevant to the structure, determine the relevant damage factors

δx and special hazard factors.

(e) For each type of loss relevant to the structure, determine the maximum tolerable risk,

Ra.

(f) For each type of loss relevant to the structure, calculate the risk due to lightning by—

(i) identifying the components Rx that make up the risk (see Figure 2.1);

(ii) calculating the identified risk components Rx; and

(iii) calculating the total risk due to lightning, R.

(g) Compare the total risk R with the tolerable value Ra for each type of loss relevant to

the structure.

If R ≤Ra (for each type of loss relevant to the structure) lightning protection is not

necessary.

If R >Ra (for any type of loss relevant to the structure) the structure shall be equipped with

protection measures against lightning.

The selection of the most suitable protection measures shall be made by the designer

according to the contribution of each risk component to the total risk, and according to the

technical and economic aspects of the different protection measures available. Technical

considerations include addressing the highest risk components while economic

considerations involve minimizing the total cost to achieve a suitable level of protection. Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 24: ASNZS 1768-2007

AS/NZS 1768:2007 22

COPYRIGHT

It is appropriate to consider separately the risk Rd due to direct lightning strikes and the risk

Ri due to indirect lightning strikes.

2.6.2 Protection against direct lightning strikes if Rd > Ra

When the risk due to direct lightning strikes is greater than the acceptable risk (Rd > Ra),

then the structure shall be protected against direct lightning strikes with an LPS designed

and installed in accordance with the recommendations given in Section 4.

In Section 4, four protection levels (I, II, III, IV) with corresponding interception

efficiencies (99%, 97%, 91%, 84%) and resulting LPS efficiencies, E (98%, 95%, 90%,

80%) are defined.

To determine the required protection level, the final calculation for the protected structure

may be repeated successively for the protection levels IV, III, II, I until the condition Rd ≤

Ra is fulfilled.

NOTE: A previous edition, AS 1768—1991, specified LPSs with protection equivalent to IEC

Level III (interception efficiency ≈ 91%)—Rolling sphere with a = 45 m)

If an LPS of protection level I cannot fulfil this condition, consider surge protection on all

incoming conductive electrical service lines at the point-of-entry to the structure or other

specific protection measures according to the values of the risk components (refer to

detailed calculations and assumptions in Appendix E). These may include—

(a) measures limiting step and touch voltages;

(b) measures limiting fire propagation;

(c) measures to mitigate the effects of lightning-induced overvoltages (e.g. additional,

coordinated surge protection or isolation transformers); and

(d) measures to reduce the incidence of dangerous discharges (e.g. bonding of structural

elements).

2.6.3 Protection against indirect lightning strikes if Rd ≤ Ra but Ri > Ra

When Rd ≤ Ra, then the structure is protected against direct lightning strikes. However, if the

risk due to indirect strikes is greater than the acceptable risk (Ri > Ra), then the structure

must be protected against the effects of indirect lightning strikes.

Possible protection measures include—

(a) suitable application of SPDs on all external conductive electrical service lines at the

point-of-entry to the structure (primary or point-of-entry surge protection); and

(b) suitable application of SPDs on all internal equipment (secondary surge protection at

the equipment).

NOTE: Suitable application of surge protection requires correct installation, earthing and

coordination of appropriately rated SPDs.

To determine the required protection, the final calculation for the protected structure shall

be repeated with one or both of these protection measures in place until the condition Ri ≤

Ra is fulfilled.

If the application of these protection measures cannot fulfil this condition, specific

protection measures shall be provided according to the values of the risk components (refer

to detailed calculations and assumptions in Appendix A). These may include magnetic

shielding of the structure and/or of the equipment and/or of cable ways and/or by using

cable screening. It may also be appropriate to have extra zones of protection around

sensitive areas with an extra level of SPD protection at the boundary of that zone.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 25: ASNZS 1768-2007

23 AS/NZS 1768:2007

COPYRIGHT

2.6.4 Final check if Rd + Ri > Ra

When Rd ≤ Ra and Ri ≤ Ra it is still possible that the total risk R = Rd + Ri > Ra.

In this case, the structure does not require any specific protection against direct lightning

strikes or against overvoltages due to nearby strikes or transmitted through the incoming

conductive electrical service lines.

However, since R > Ra, protection measures shall be taken to reduce one or more risk

components to reduce the risk to R ≤ Ra. Critical parameters have to be identified to

determine the most efficient measure to reduce the risk R.

For each type of loss, there are a number of protection measures that, individually or in

combination, may make the condition R ≤ Ra.

Those measures that make R ≤ Ra for all the types of loss must be identified and adopted

with due consideration of the associated technical and economic issues.

2.7 RISK MANAGEMENT CALCULATION TOOL

A Microsoft® Excel spreadsheet file has been included as a risk management calculation

tool. This file (LIGHTNING RISK.XLS) is provided as an integral part of the Standard and

is designed to operate using Microsoft®

Excel 97 (or later versions).

The spreadsheet implements the risk calculations detailed in Appendix A with the required

inputs and outputs presented on a single page for ease of use. The risk calculations

implemented represent a simplification of the approach outlined in initial work by IEC

Committee TC 81 with the number of variables and options requiring selection reduced to a

minimum based on assumptions for general conditions in Australia and New Zealand.

In addition, a simplified form of the equation for risk component Rs (risk related to physical

destruction) has been used, and the classification descriptions for fire risks based on

structure type and content (ps) have been modified, in order to reduce the fire risk

sensitivity of the draft IEC model. These modifications have been made to give more

practical values based on experience in Australia and New Zealand.

2.7.1 General operation

When the file is opened using Microsoft® Excel, a front page spreadsheet is displayed. This

front page presents all of the inputs and final calculation outputs required in the risk

management process. Other work sheets showing the calculated values of all of the

individual risk components for each type of risk are also accessible if a more in depth

analysis is required.

On the front page, the required inputs are subdivided into various categories with input cells

highlighted with a border. The possible input options are explained in a comment box,

which is displayed when the cursor is positioned over the input cell.

For most input cells, the input option is selected from a pull-down menu of key words that

are defined in the associated comment box. Some inputs require numerical values (e.g.

structure dimensions), which should be entered in the usual way from the keyboard.

When all of the inputs have been entered, the output values in the ‘Risk’ section represent

the calculated risk components and overall risk for the particular set of structure parameters

and conditions specified.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 26: ASNZS 1768-2007

AS/NZS 1768:2007 24

COPYRIGHT

2.7.2 Using the calculation tool in the risk management procedure

The calculation tool can be used in the following way to implement the risk assessment and

management procedure outlined in Clause 2.6.

(a) Identify the structure and input the structure dimensions.

(b) Input the structure attributes relating to fire risk, screening effectiveness and internal

wiring.

(c) Determine the average annual lightning ground flash density (Ng) for the structure

location from the appropriate Ground Flash Density map (Figure 2.3 or 2.4) and input

the value in the environment section.

NOTES:

1 Earlier editions of AS/NZS 1768 provided thunderday maps, refer Appendix B2.3.

2 An approximate relationship between ground flash density (Ng) and thunderdays (Td) for

Australia is Ng = 0.012 Td1.4.

(d) Input the other environment attributes relating to surrounding feature height and

service density.

(e) Specify the details of the conductive electrical service lines associated with the

structure in the following way:

(i) Input the type of electricity supply service line and identify whether or not a

transformer is installed on this service line at the structure.

(ii) Input the number and type of other overhead or underground conductive

electrical service lines connected to the structure via divergent routes.

NOTES:

1 Different service lines that follow the same physical route from the nearest

distribution node to the structure should be considered as one service line

connection.

2 Typically a structure will have one electricity supply service connection (overhead

or underground) and one telecommunications service connection (overhead or

underground) that could be considered as being connected via divergent routes.

(f) Identify the loss types relevant to the structure and for each type input the damage

factors and special hazard factors as appropriate.

(g) Determine and input an appropriate value for the acceptable risk of loss of economic

value as it applies to the structure.

(h) Input details of any protection measures installed. The surge protection options

offered are for:

(i) Suitable application of SPDs on all external conductive electrical service lines

at the point-of-entry to the structure (primary or point-of-entry surge

protection).

(ii) Suitable application of SPDs on all electrical equipment inside the structure

(secondary surge protection at the equipment).

NOTE: Suitable application of surge protection requires correct installation, earthing and

coordination of appropriately rated SPDs.

For each type of loss relevant to the structure, compare the acceptable risk with the total

risk calculated. Review the risk components and follow the Risk Management procedure

detailed in Clause 2.6 and Figure 2.2.

Use the spreadsheet to recalculate the risk components and total risk figures for any

protection measures proposed. Successive calculations can be performed to observe the

effects of various protection measures.

A number of completed spreadsheet examples are provided for information in Appendix A.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 27: ASNZS 1768-2007

25 AS/NZS 1768:2007

COPYRIGHT

* Refer to Section 4.

NOTE: A previous edition, AS 1768—1991, specified an LPS with protection equivalent to Level III—Rolling

sphere with a=45 m.

FIGURE 2.2 RISK MANAGEMENT PROCEDURE FOR SELECTION OF LIGHTNING

PROTECTION MEASURES

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 28: ASNZS 1768-2007

COPYRIGHT

26 AS/NZS 1768:2007

NO

TE

: T

he A

ust

rali

an

Gro

un

d F

lash

Den

sity

map

has

been

co

mp

iled

an

d k

ind

ly s

up

pli

ed

by

th

e A

ust

rali

an

Bu

reau

of

Mete

oro

log

y a

nd

th

e U

niv

ers

ity

of

Qu

een

slan

d.

FIG

UR

E

2.3

A

VE

RA

GE

AN

NU

AL

LIG

HT

NIN

G G

RO

UN

D F

LA

SH

DE

NS

ITY

MA

P O

F A

US

TR

AL

IA

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 29: ASNZS 1768-2007

27 AS/NZS 1768:2007

COPYRIGHT

NOTE: This figure has been derived from ground flash density data obtained from the Lightning Detection

Network of New Zealand for the period January 1, 2001 through February 9, 2006. Data supplied by

Transpower New Zealand Ltd and the Meteorological Service of New Zealand Ltd (MetService).

FIGURE 2.4 AVERAGE ANNUAL LIGHTNING GROUND FLASH DENSITY MAP

OF NEW ZEALAND

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 30: ASNZS 1768-2007

AS/NZS 1768:2007 28

COPYRIGHT

S E C T I O N 3 P R E C A U T I O N S F O R P E R S O N A L

S A F E T Y

3.1 SCOPE OF SECTION

This Section provides guidance for personal safety during thunderstorms.

Measures for the protection of persons, which should be incorporated in LPSs for buildings

and structures, are outlined in other sections.

For shelters designed for the protection of persons during storm activity, reference should

be made to Clause 6.9.1.

3.2 NEED FOR PERSONAL PROTECTION

A hazard to persons exists during a thunderstorm. Each year a number of persons are struck

by lightning, particularly when outdoors in open space such as an exposed location on a

golf course, or when out on the water. Between six and ten people are killed by lightning in

Australia each year. This is equivalent to a probability of about 5 × 10 –7 per year for an

individual being killed by lightning in Australia.

Lightning strikes to a person, or close by, may cause death or serious injury. A person

touching or close to an object struck by lightning may be affected by a side-flash, or receive

a shock due to step, touch or transferred potentials. There is a significant risk of side-flash

for people in small, public structures such as picnic shelters, particularly those with

unearthed metallic roofs. In built-up areas protection is frequently provided by nearby

buildings, electricity supply service lines or street lighting poles.

Persons within a substantial structure are normally protected from direct strikes, but may be

exposed to a hazard from conductive electrical services entering the structure or from

conductive objects within the structure that may attain different potentials.

The first recorded ‘electrical accident’ involving the use of a telephone occurred in 1860

and was caused by lightning being conducted through the telephone system. Telephone

related injuries include acoustic and/or electric shock. About 10% of injuries are severe. No

telephone related deaths have been reported in Australia. This is probably because of

warnings not to use the telephone, except in an emergency, during a lightning storm and the

use of SPDs on telephone installations in lightning prone areas. Around 80% of incidents

involve a lightning strike to or close to a building or a strike to the electricity supply service

line all of which result in a rise of the local earth potential rather than surges on the

telecommunications service line. This rise in local earth potential can result in a breakdown

between the person and the telephone, (which is connected to a nominal remote earth via

the telecommunications service line).

In some workplaces employees who work within larger buildings may be unaware of the

changing outside weather conditions, and may not be aware that it may be unsafe to use

telephone systems. Where modern fixed line telephonist headsets are used, this increases

the risk of human injury through external transients being conducted through to those

wearing the headsets.

When moderate to loud thunder is heard, persons out of doors should avoid exposed

locations and should seek adequate shelter. Persons indoors should avoid using the

telephone and contacting metallic structures. These warnings apply particularly if thunder

follows within 15 s of a lightning flash (corresponding to a distance of less than 5 km).

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 31: ASNZS 1768-2007

29 AS/NZS 1768:2007

COPYRIGHT

3.3 PERSONAL CONDUCT

3.3.1 General

The threat to personal safety is greatest if a person is out of doors when the thunderstorm is

local. In the absence of specific information from weather radar, a lightning location system

or a specialized lightning warning device, the ‘30/30’ safety guideline (Paragraph G2, Ref.

1) should be used. An approaching thunderstorm is treated as local when the time interval

between seeing a lightning flash and hearing the thunder is less than 30 s and then the

appropriate safety measures described in Clause 3.3.2 should be implemented. A receding

local thunderstorm is no longer a threat when more than 30 min have elapsed after the last

thunder is heard.

3.3.2 Outdoors

When outdoors, some of the measures for reducing the risk of injury that may be caused by

lightning strikes to ground during a local thunderstorm are as follows:

(a) Seek shelter in a substantial building with at least normal headroom or within a

totally enclosed, metal-bodied vehicle such as car or truck with metallic roof. If in a

car, close the windows and avoid contact with metallic parts and remove any hands-

free mobile telephone attachments from the body. Avoid driving the car as a strike to

the car may blow out the tyres. Do not stay in open vehicles such as tractors, beach

buggies, or any other type of open or enclosed vehicle without a metallic roof.

Conventional fabric tents offer no protection; small sheds offer uncertain protection.

(b) Do not ride or sit on horses, bicycles or motorcycles, or otherwise elevate the body

above the surroundings.

(c) Do not shelter under trees, particularly an isolated tree. If surrounded by trees, seek a

position outside the foliage and crouch, keeping the feet together.

(d) Do not shelter in small sheds, pagodas, walkways etc. with low unearthed metallic

roofs supported on wooden or other electrically insulating materials.

(e) Do not touch or stand close to any metallic structures, including wire fences and

clothes lines. Do not stand on or under bridges or other elevated structures. Do not

carry metallic objects such as umbrellas or golf clubs and remove metallic chains and

other jewellery, particularly from the head and upper parts of the body.

(f) If on open field or on the beach and remote from any shelters, keep as low and as

small a profile as possible, i.e. crouch keeping the feet together and do not touch any

objects or people near you. A dry ditch, valley or any depression in the ground is

safer than an elevated or flat terrain. Do not lie on the ground as this could cause

dangerous voltage to develop across the body by earth currents generated by a nearby

strike. Footwear or a layer of non-absorbing, insulating material, such as plastic

sheets, can offer some protection against earth voltages.

(g) Do not swim or wade in the sea, lake, river, pool or any other body of water.

Exit the water and move to a safe place.

(h) If on a boat deck, keep a low profile and avoid contacts with or being close to masts,

rails, stay wires or any other metallic objects. Avoid unnecessary contacts with

communication or navigation equipment. Do not enter the water, and in general avoid

contact with water. Additional protection may be gained by anchoring under

relatively high objects such as jetties and bridges, provided that direct contact is not

made with them. Isolated buoys and pylons should be avoided.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 32: ASNZS 1768-2007

AS/NZS 1768:2007 30

COPYRIGHT

In addition, the following checks should be made when planning outdoor activities:

(i) Check weather reports for likely thunderstorms.

(ii) When engaged in outdoor activities, monitor the surroundings for indications of the

onset of thunderstorms. These checks are particularly important when planning and

undertaking activities involving groups and large numbers of people.

3.3.3 Indoor and outdoor swimming pools

Certain locations are extremely hazardous during thunderstorms and should be avoided if at

all possible. Statistics show that more than 10% of lightning-related injuries and deaths are

water related (e.g. fishing, boating and swimming). Swimming pool facilities are connected

to a large surface area via underground water pipes, gas lines, electric and telephone wiring,

etc. Hence, lightning strikes to the ground anywhere on this metallic network may cause

shocks elsewhere. Indoor and outdoor pools are treated the same with regard to lightning

dangers.

The following swimming pool safety procedures are recommended:

(a) A person should be designated as the pool’s weather safety lookout. That person

should keep an eye on the weather and use the appropriate means to obtain localized,

advanced weather information.

(b) Identify in advance safe/not safe places—

(i) Safe—dry areas inside large permanent buildings.

(ii) Not safe—near electrical conductors, electrical equipment, metal objects

(lifeguard stands, ladders, diving board stanchions) and water, including

showers.

(c) When thunder and/or lightning are first noticed, use the ‘30/30 method’ described in

Clause 3.3.1. The pool should be evacuated in a time interval of less than 30 s and

people should be directed to a safe shelter nearby.

3.3.4 Indoors

When indoors, some of the measures for reducing the risk of injury that may be caused by

lightning strikes to ground during a local thunderstorm are as follows:

(a) Avoid unnecessary use of telephones particularly in suburban and rural dwellings

during local thunderstorms. If unavoidable, keep it brief and try not to touch electrical

appliances, personal computers, metal pipes, stoves, sinks, and any other metallic

objects at the same time. Mobile and cordless telephones are safe to use indoors.

Where headsets are used for a large percentage of the time, or where operators may

be unaware of local lightning storms, the risk of injury from lightning can be

dramatically reduced by the use of wireless headsets.

(b) Do not take a bath or a shower and do not wash hands or dishes. Do not use personal

computers and other electronic and electrical equipment, and avoid contacts with

sinks, stoves, refrigerators, metallic pipes and other large metallic objects in the

house.

(c) Disconnect television sets, personal computers, video recorders and other electronic

and electrical appliances from antennas, conductive telecommunication connections

and electricity supply outlets to avoid damage to them. This should be done before

the storm is local to minimize risk of personal injury.

NOTES:

1 Switching off an appliance does not disconnect neutral and earth wiring.

2 Switching off the electricity supply at the switchboard may also reduce the chances of

damage to the electrical wiring and to permanently wired electrical appliances. Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 33: ASNZS 1768-2007

31 AS/NZS 1768:2007

COPYRIGHT

3.4 EFFECT ON PERSONS AND TREATMENT FOR INJURY BY LIGHTNING

The severity of the injuries inflicted on a person by a lightning strike will depend upon the

intensity of the strike and for any given strike, on the fraction of the current that flows over

the skin outside the body and the fraction that flows through the body, and its path. The

worst situation would arise when a person is struck on the head, in which case the current

through the body could cause fatal injuries to the brain, the heart and the lungs. A less

dangerous situation is where the person is subjected to step or touch potentials, and only a

small fraction of the total current passes through the body, although the pathway taken by

this fraction is still important.

The effects of lightning include burns to the skin, which are usually superficial, damage to

various bodily organs and systems, unconsciousness and, most dangerously, cessation of

breathing and cessation of heart beat. Independently of these electrically-related effects,

temporary or permanent hearing impairment may be experienced as a consequence of the

extremely high sound pressure levels associated with a nearby lightning strike.

In the first aid treatment of a patient injured by lightning, it is essential that breathing be

restored by artificial respiration and blood circulation be restored by external cardiac

massage, if appropriate. These procedures should be continued until breathing and heart

beat are restored, or it can be medically confirmed that the patient is dead. It should also be

noted that the usual neurological criteria for death may be unreliable in this situation. There

is no danger in touching a person who has been struck by lightning.

Lightning strike victims are sometimes thrown violently against an object, or are hit by

flying fragments of a shattered tree, so first aid treatment may have to include treatment for

traumatic injury.

Subsequent treatment of a lightning strike patient is a specialized area with important

differences from the treatment of injuries inflicted by electric power current. For example,

the nature of the burns and the extent of damage to underlying muscle tissue tend to be

severe with electric power current, but mild with lightning current. Neurological and

cardiac injuries also are different, and follow different courses.

NOTE: For a more comprehensive treatment of the subject covered by this Clause—see

Paragraph G2, Ref. 2.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 34: ASNZS 1768-2007

AS/NZS 1768:2007 32

COPYRIGHT

S E C T I O N 4 P R O T E C T I O N O F S T R U C T U R E S

4.1 SCOPE OF SECTION

This Section sets out recommendations for installation practices and for the selection of

equipment to prevent or to minimize damage or injury that may be caused by a lightning

discharge. The recommendations apply generally to the protection of structures using LPSs

comprising air terminals, downconductors, equipotential bonding and earth terminations.

If, after completing the LPS risk assessment, it is evident that surge protection is required to

protect internal systems within the building and services at entry to the buildings then the

requirements of Section 5 shall be applied.

4.2 PROTECTION LEVEL

Four protection levels (PL) I, II, III, IV are used to define the efficiency with which the

LPS is designed to protect the structure against physical damage and life hazard. The

protection level efficiency (η) has two components–interception protection efficiency (ηI),

which characterizes the effectiveness of the air terminals, and sizing protection efficiency

(ηS), which characterizes the effectiveness of the downconductors and the earth

terminations. Each is determined independently—by the minimum lightning current (I, kA)

that will be intercepted, and by the maximum sizes of lightning current, charge (Q, C) and

current steepness (di/dt, kA/μs) that will be discharged safely. The four protection levels

are based on IEC TC 81 documents and are defined in Table 4.1.

TABLE 4.1

PROTECTION LEVELS

Protection level Interception efficiency Sizing efficiency LPS efficiency

PL ηI ηS η

I

II

III

IV

0.99

0.97

0.91

0.84

0.99

0.98

0.97

0.97

0.98

0.95

0.90

0.80

4.3 LPS DESIGN RULES

4.3.1 General

The following Clauses provide the details of the recommendations for the design and

installation of all the LPS elements. This Clause lists the overriding design rules that shall

normally be observed to provide minimum requirements for air terminals,

downconductors and earth terminations. Observance of these rules will ensure that

appropriate interception protection is provided by air terminals for the parts of structures

most likely to be damaged by direct lightning strikes, that the conduction of the lightning

current by the downconductors is adequate and that it is dissipated into the earth by the

earth terminations.

These rules are the first step in the process of the design of a complete LPS. The remaining

steps are referred to in the design rules and their application is referred to in subsequent

sections.

NOTE: These design rules may not apply to some small structures.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 35: ASNZS 1768-2007

33 AS/NZS 1768:2007

COPYRIGHT

Field data of damage caused by lightning flashes terminating on structures (See

Paragraph G2, Refs. 3 and 4) identify the parts that are vulnerable to strikes. The most

vulnerable, associated with over 90% of observed lightning damage, are nearly always

located on the upper parts of structures, such as—

(a) pointed apex roofs, spires and protrusions;

(b) gable roof ridge ends; and

(c) outer roof corners.

Other areas of vulnerability, in decreasing order, are—

(d) the exposed edges of horizontal roofs, and the slanting and horizontal edge of gable

roofs (<10%);

(e) lower horizontal edges and vertical edges on outer-sides just below corners (<5%);

(f) flat surfaces near points and corners (<3%); and

(g) intruding surfaces and other surfaces, particularly flat surfaces (<1%).

As discussed in later Sections, the vulnerability is caused mainly by the electric field

intensification associated with exposed points and corners on the upper surfaces of

structures. It is obvious that air terminals must be installed to provide interception for the

most vulnerable parts.

As well as providing conductive paths for the lightning current from the air terminals to the

earth terminals, the downconductors should assist in preventing side-flashes to nearby metal

elements (including reinforcing bars). This is best done by locating downconductors

immediately below the air terminals used to protect the most vulnerable parts.

4.3.2 Rules for air terminals

(a) First, provide air terminals to protect the most vulnerable parts (points and corners);

second, use the rolling sphere method (RSM) to check if the less vulnerable parts

(edges) are protected and, if not, add more terminals to protect them; third, also check

if the least vulnerable parts (such as flat surfaces) are protected and, if not, add more

terminals.

(b) Air terminals shall be placed on or close to the most vulnerable parts; if a strip

conductor is used, it shall be directly on the part it is to protect; if a vertical rod is

used, its length shall be not less than 500 mm, and it shall preferably be mounted on

the part it is to protect or within 1 m or 1/2 its length, whichever is the smaller (this

rule is supported by recent research – see Paragraph G2, Ref. 5). The maximum

allowable length of a rod terminal is 6 m.

(c) If the structure has horizontal or gently sloping upper parts that are essentially

cylindrical or oval in shape, then the edges are the vulnerable parts and shall be

protected by air terminals; if a strip conductor is used, it shall be run along the

edge(s); if vertical rods are used, there shall be a minimum of two evenly spaced

terminals.

(d) Non-conventional LPS using air terminals that claim enhanced performance are

outside the scope of this Standard. To comply with this Standard and irrespective of

claimed performance, air terminals shall be placed in accordance with the relevant

clauses of this Section.

4.3.3 Rules for downconductors

(a) Main conductors shall interconnect all air terminals and shall form one or more paths

to earth via downconductors, such that the spacing between the downconductors does

not exceed 20 m.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 36: ASNZS 1768-2007

AS/NZS 1768:2007 34

COPYRIGHT

(b) A downconductor shall be connected directly below an air terminal used to protect the

most vulnerable parts; if the air terminal is on an exposed roof corner, its

downconductor will also act as a continuation of the air terminal to protect the

vertical edge below it, as is required for tall structures.

4.3.4 Rules for earth terminations

(a) Low earth resistance is desirable and all practical measures should be taken to

achieve 10 Ω or less for the whole interconnected LPS earth termination network.

There shall be equipotential bonding at ground level for all metallic surfaces.

If the risk assessment indicates a need for SPDs, these shall be installed and bonded

in accordance with Section 5.

(b) There shall be one earth termination per downconductor.

4.4 ZONES OF PROTECTION FOR LIGHTING INTERCEPTION

4.4.1 Basis of recommendations

The selected interception protection efficiency against direct lightning strikes is achieved

by installing an LPS in such a way that its air terminals establish zones of protection

enclosing the whole structure. For the calculation of these zones of protection, the RSM,

with a modification for large flat surfaces, is used.

The RSM generally ensures that for lightning striking distances determined by the radius of

the rolling sphere, the shortest distance between a lightning leader tip and any part of the

structure is an air terminal.

This method of analysis is suitable for conventional lightning terminals, which may be

vertical rods, horizontal wires or strip conductors, railings, metal sheets, fascias and so on.

4.4.2 Rolling sphere method (with a modification for large flat surfaces)

In the ‘rolling sphere’ technique of determining zones of protection, a sphere of specified

radius (a) is theoretically brought up to and rolled over the total structure. All sections of

the structure that the sphere touches are considered to be exposed to direct lightning strokes

and would need to be protected by air terminals. In general, air terminals need to be

installed so that the sphere only touches their interception surfaces. This is illustrated in

Figure 4.1, which shows that the top corner/edge of the structure requires protection by an

air terminal but the sides and lower section do not. The values of the rolling sphere radius

(a) for the four protection levels (PL) I, II, III, IV are given in Table 4.2 together with the

corresponding minimum lightning current (Imin) that will be intercepted.

TABLE 4.2

ROLLING SPHERE RADIUS FOR EACH PROTECTION LEVEL

Protection level Sphere radius Interception current†

PL a, m (ai)* Imin , kA

I

II

III

IV

20 (60)

30 (60)

45 (90)

60 (120)

2.9

5.4

10.1

15.7

* The values in brackets are for increased radius (ai), see below.

† Values from IEC documents, which use distributions of lightning current parameters that

differ slightly from those in Table B1 of Appendix B.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 37: ASNZS 1768-2007

35 AS/NZS 1768:2007

COPYRIGHT

FIGURE 4.1 ZONE OF PROTECTION ON A STRUCTURE ESTABLISHED BY

A ROLLING SPHERE OF RADIUS a

It is common to consider that PL III using a sphere of radius a, 45 m provides ‘standard’

protection (as in AS/NZS 1768(Int):2003 and NFPA 780—2004). PL I and II with a, 20 and

30 m provide higher degrees of protection and should be used if required by the risk

management calculations of Section 2 and Appendix A. Conversely, PL IV with a, 60 m

provides a lower degree of protection. For PL III, the protection ensures that, for striking

distances of 45 m or more, the shortest distance to the structure is to an air terminal. From

Tables 4.1 and 4.2, such striking distances correspond from empirical observations to peak

currents of 10 kA or more, and an interception efficiency of 91%, there being only of the

order of 9% of strikes having a lower current. In the RSM, lightning is considered most

likely to follow the path of shortest distance. This path will have the highest average

electric field produced by the potential difference between the tip of the lightning leader

(likely to be at more than 10 MV) and the structure (approximately at earth potential).

The RSM produces a conservative design since it makes no allowance for field

intensification at the edges and corners of structures. Using a constant radius for the rolling

sphere the sides and tops of structures are assigned an equal probability of lightning strike

to the corners and edges.

In particular, the ‘rolling sphere’ method is unduly conservative for large flat surfaces, such

as on the roof of a structure and on the sides of tall structures, both of which are unlikely to

be struck by lightning. Further advice on the protection of roofs is given in Clause 4.11.2.

A simple modification to the RSM can overcome the former problem (See Paragraph G2,

Ref. 6). The basis of the modification is that the application of the RSM will be a two-step

process in which—

(a) the air terminal network is first selected and positioned to provide interception

protection for points, corners and edge surfaces using a rolling sphere of radius (a)

selected from Table 4.2; and

(b) the selected and positioned air terminal network is then used to determine if

protection is provided to all plane (flat) surfaces using a rolling sphere with the

corresponding increased radius (ai) in Table 4.2; if not, more air terminals are added

to protect the exposed plane surface(s) still using the rolling sphere of radius (ai).

For the purposes of this modification to the RSM, a plane surface is defined as any large

flat surface that has no projection from it exceeding 300 mm. Any flat surface is considered

to be large if, after step (b), it is apparent that more air terminals are required to protect it.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 38: ASNZS 1768-2007

AS/NZS 1768:2007 36

COPYRIGHT

According to the RSM, an air terminal of height h above the edge of a flat roof or

horizontal plane is considered to protect the edge of that roof or plane up to a horizontal

distance r from a vertical rod or a horizontal conductor, where r is given by:

( )22 hhar −= . . . 4.4.2(1)

in which a is the sphere radius from Table 4.2 and r, a and h are in metres.

For points on the flat surface, according to the modification to the RSM, the protection

extends to a distance ri from the air terminal, given by:

( )2ii

2 hhar −= . . . 4.4.2(2)

in which ai is the increased radius from Table 4.2. For all but small horizontal surfaces, an

array of air terminals is required at spacing distances that ensure that no parts of the surface

are unprotected. If the array is a square grid, the spacings must not exceed dvr for vertical

rods and dhc for horizontal conductors, given by:

2ivrrd ≤ and ihc

2 rd ≤ . . . 4.4.2(3)

Some numerical values are given to illustrate the magnitudes; for protection level III, a is

45 m and ai is 90 m, then when the air terminal of height h is 1 m, r is 9.4 m, ri is 13.4 m,

dvr is 19 m and dhc is 26.8 m. Table 4.3 provides information on the spacings of air

terminals required to protect roofs at each of protection levels I to IV for the three most

common heights of air terminals used in Australia and New Zealand.

Figures 4.2 and 4.3 illustrate the application of the RSM (with the modification for flat

surfaces) to a rectangular structure using either vertical rods or horizontal conductors.

Figure 4.2 (Step (a)) deals with the interception protection for the vulnerable corners and

horizontal edges and Figure 4.3 (Step (b)) shows how Equations 4.4.2(2) and 4.4.2(3) are

used for the flat roof.

For more complex structures, the technique of rolling the sphere must be used directly to

determine the required configuration of air terminals needed to achieve the interception

protection efficiency that has been selected.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 39: ASNZS 1768-2007

37 AS/NZS 1768:2007

COPYRIGHT

Step (a): Protect corner and edge surfaces

Either, Place vertical rods at 4 corners, try h = 1 m (shown).

Using Equation 4.4.2(1) r = ah h2(2 )− = 9.4 m

Max spacing along edge = 2 × 9.4 = 18.6 m Therefore, 3 additional rods are needed along each edge Check with rolling sphere of radius 45 m, okay (shown)

or Place metal railings h = 1 m along the 4 edges (not shown) This protects all 4 corners and 4 edges

FIGURE 4.2 APPLICATION OF STEP (a) OF RSM (WITH THE MODIFICATION FOR

FLAT SURFACES) FOR PROTECTION LEVEL III FOR A RECTANGULAR STRUCTURE

OF DIMENSIONS 70 X 50 X 20 m USING EITHER VERTICAL ROD OR RAISED

HORIZONTAL CONDUCTOR AIR TERMINALS

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 40: ASNZS 1768-2007

AS/NZS 1768:2007 38

COPYRIGHT

Step (b): Using increased sphere radius ai to determine if more terminals are required

14 × 1 m rods plus 4 × 1.25 m rods Using Equation 4.4.2(2),

ri = a h h2

i(2 )− = 15 m

The building is protected

FIGURE 4.3(a) APPLICATION OF STEP (b) OF RSM (WITH THE MODIFICATION FOR

FLAT SURFACES) FOR PROTECTION LEVEL III FOR A RECTANGULAR STRUCTURE

OF DIMENSIONS 70 × 50 × 20 m USING 4 × 1.25 m VERTICAL RODS ON THE INTERIOR

PLANE SURFACE

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 41: ASNZS 1768-2007

39 AS/NZS 1768:2007

COPYRIGHT

Step (b): Using increased sphere radius ai to determine if more terminals are required

14 × 1 m rods plus 2 × 1.6 m rods Using Equation 4.4.2(2),

ri = a h h2

i(2 )− = 16.9 m

The building is protected

FIGURE 4.3(b) AN ALTERNATIVE APPLICATION OF STEP (b) OF RSM (WITH THE

MODIFICATION FOR FLAT SURFACES) FOR PROTECTION LEVEL III FOR A

RECTANGULAR STRUCTURE OF DIMENSIONS 70 × 50 × 20 m USING 2 × 1.6 m

VERTICAL RODS ON THE INTERIOR PLANE SURFACE

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 42: ASNZS 1768-2007

AS/NZS 1768:2007 40

COPYRIGHT

Step (b): Using increased sphere radius ai to determine if more terminals are required

Either, 1 (or more) additional raised horizontal conductors h = 1 m to protect the flat roof

Using Equation 4.2.2(2), ri = a h h2

i(2 )− = 13.4 m

Using Equation 4.2.2(3), dhc ≤ 2ri = 26.8 m, but is < the 70 m between the edge railings, and so the 4 railings along the edges do not protect all the roof Add 2 additional raised horizontal conductors h = 1 m and all the roof is protected (shown)

So need 4 × 1 m high railings plus 2 additional 1 m high raised horizontal conductors

or The 2 additional raised horizontal conductors could be replaced by 2 × 1.5 m vertical rods (r = 16.4 m) as shown

FIGURE 4.3(c) AN ALTERNATIVE APPLICATION OF RSM (WITH MODIFICATION FOR

FLAT SURFACES) FOR PROTECTION LEVEL III FOR A RECTANGULAR STRUCTURE

OF DIMENSIONS 70 × 50 × 20 m USING RAISED HORIZONTAL CONDUCTORS ONLY

OR RAISED HORIZONTAL CONDUCTORS ON BUILDING CORNERS AND EDGES AND

VERTICAL RODS ON THE INTERIOR PLANE SURFACES

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 43: ASNZS 1768-2007

COPYRIGHT

41

AS/NZS 1768:2007

TA

BL

E

4.3

HE

IG

HT

AN

D S

PA

CIN

G O

F A

IR

TE

RM

IN

AL

S T

O P

RO

TE

CT

RO

OF

S

dim

en

sio

ns

in m

etr

es

Ed

ges

an

d c

orn

ers

of

ro

of

pro

tecte

d b

y v

erti

ca

l

ro

d o

r r

ais

ed

ho

riz

on

tal

co

nd

ucto

r

Mid

dle

of

fla

t ro

of

Ho

riz

on

tal

dis

tan

ce f

or

wh

ich

ro

of

is p

ro

tecte

d

Ma

xim

um

sp

acin

g

for a

rra

y

Ho

riz

on

tal

dis

tan

ce f

or

wh

ich

ro

of

is p

ro

tecte

d

Ma

xim

um

sp

acin

g

for a

n a

rra

y o

f v

erti

ca

l

ro

ds

Ma

xim

um

sp

acin

g f

or

ra

ised

ho

riz

on

tal

co

nd

ucto

r2

)

Pro

tecti

on

lev

el

Heig

ht

of

air

term

ina

l 1

)

h

r

((

)2

2h

ha

−=

)

d

(= r

.2)

ri

((

)2

i2

hh

a−

=)

dv

r

(2

ir

=)

dh

c

(= r

i.2

)

I

(a =

20

m,

ai =

60

m)

0.5

1

2

4.4

6.2

8.7

8.9

12

.5

17

.4

7.7

10

.9

15

.4

10

.9

15

.4

21

.7

15

.5

21

.8

30

.7

II

(a =

30

m,

ai =

60

m)

0.5

1

2

5.5

7.7

10

.8

10

.9

15

.4

21

.5

7.7

10

.9

15

.4

10

.9

15

.4

21

.7

15

.5

21

.8

30

.7

III

(a =

45

m,

ai =

90

m)

0.5

1

2

6.7

9.4

13

.3

13

.4

18

.9

26

.5

9.5

13

.4

18

.9

13

.4

18

.9

26

.7

18

.9

26

.8

37

.7

IV

(a =

60

m,

ai =

12

0 m

)

0.5

1

2

7.7

10

.9

15

.4

15

.5

21

.8

30

.7

10

.9

15

.5

21

.8

15

.5

21

.9

30

.9

21

.9

30

.9

43

.6

1)

Fo

r o

ther

air

term

inal

heig

hts

(h

) u

se e

qu

ati

on

s 4

.4.2

(1),

(2

) an

d (

3).

2)

Fo

r fu

rth

er

info

rmati

on

on

rais

ed

ho

rizo

nta

l co

nd

ucto

rs p

laced

on

th

e r

oo

f, s

ee C

lau

se 4

.11

.2.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 44: ASNZS 1768-2007

AS/NZS 1768:2007 42

COPYRIGHT

4.5 METHODS OF PROTECTION

4.5.1 Structural steel-framed buildings

Buildings with structural steel framing may be protected by the installation of metal air

terminals at the high parts of the building, the air terminals being connected to the steel

framing and the framing earthed in the vicinity of the foundation. A typical LPS is shown in

Figure 4.4 (see also Clause 4.16.1).

4.5.2 Buildings without structural steel frames

4.5.2.1 General

The required conditions of protection for non-metallic buildings are generally met by

placing metal air terminals on the uppermost parts of the building or its projections, with

conductors connecting the air terminals to each other and to earth. By this means a

relatively small amount of metal properly positioned and distributed can afford a

satisfactory degree of protection and, if desired, the material may be placed so as to give

minimum interference to the appearance of the building. A typical LPS is shown in

Figure 4.5. Additional methods utilizing the individual characteristics of particular types of

building construction are given in Clauses 4.5.2.2 to 4.5.2.4, and in Figure 4.4.

4.5.2.2 Structures with continuous metal

Structures containing continuous metal, e.g. metal within a roof, wall, floor or covering

may, if the amount and arrangement of the metal is adequate in terms of the

recommendations of Clauses 4.12 to 4.16, utilize such metal as part of the LPS.

4.5.2.3 Metal-roofed buildings

Lightning tends to strike the ridges, corners, parapets and edges of building roofs.

Generally these attachment points coincide with the metal roof sheeting, capping or

guttering being fixed by multiple screws, rivets or clips directly to the supporting steel

purlins, beams and trusses below.

While a direct strike can puncture a hole in thin metal sheeting the instances of such

damage are rare (refer to Paragraph B3, Appendix B for more information). For many

buildings that are roofed, or roofed and clad, with metal, it may be possible to dispense with

some or all air terminals provided the supporting roof steelwork is directly connected to a

downconductor network or the earthing system. Any decision on dispensing with use of air

terminals should consider the consequences of possible damage to the integrity of the roof

and the contents within the building.

4.5.2.4 Reinforced concrete buildings

The following recommendations apply to the use of steel reinforcement in reinforced

concrete buildings as part of the LPS (see also Paragraph B5.5.2, Appendix B):

(a) General As far as possible, the steel reinforcement should be made electrically

continuous in all concrete elements having a structural purpose, e.g. columns, beams

and also in non-structural concrete elements, e.g. concrete wall panels, where the

element, or a part of it, if dislodged, could endanger persons below.

Where the steel reinforcement is used as the downconductor system, an effective

electrical connection should be made from the air terminal network to the steel

reinforcement at the top of the building. Such connections should be made, by means

such as welding or clamping to a minimum of four vertical and/or horizontal bars, to

ensure a multiplicity of conductive paths for the discharge of lightning current.

NOTE: Steel reinforcement that is overlapped and tied by means of wire is not considered to

provide an effective electrical connection for the purpose of air termination connection,

however, such joints are acceptable elsewhere as part of the downconductor system where

current sharing is assured. Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 45: ASNZS 1768-2007

43 AS/NZS 1768:2007

COPYRIGHT

Modern reinforced concrete structures frequently involve several structural

techniques including in situ reinforced concrete, prestressed reinforced concrete and

precast concrete; recommendations for these are listed in Items (b), (c) and (d).

(b) In situ reinforced concrete Reinforcing steel rods are tied together by steel tie wire at

splice points where reinforcing steel bars are overlapped for mechanical strength.

Despite the fortuitous nature of the metallic connection, the very large number of rods

and crossing points assures a subdivision of the total lightning current into a

multiplicity of parallel discharge paths. Experience shows that with this splicing

technique the rods can also be readily utilized as part of the LPS without thermal or

mechanical damage to the structure.

NOTE: Particular recommendations on the size, material or number of tie wires are not given

in this Standard, normal building practice being relied upon to provide adequate continuity.

Normal building practice also ensures the multiple conducting paths continue into the

building foundations (see Note). The foundations are deep in the mass of earth and

the resistivity of concrete is generally comparable with that of clay or other

moderately conductive ground. Hence, except in soils of low resistivity, the resistance

to earth from the foundation reinforcement is often lower than can be obtained

economically with driven rods, because of the much greater surface area. Concrete

foundations themselves constitute a satisfactory earth termination network but their

use, as such, precludes the inclusion of base conductors. It is desirable, however, that

a metallic connection to the reinforcing be installed, in a position suitable for the

bonding of metallic services associated with the building.

NOTE: Conductive paths may not be ensured if special building techniques are used,

e.g. grouting reinforcing bars into drilled holes in concrete after it has set, using an insulating

epoxy-based material.

(c) Prestressed reinforced concrete Prestressed reinforced concrete is used most

commonly in the horizontal structural elements in a building, such as the beams and

floor slabs, and only rarely in vertical elements such as columns. Consequently, the

principal reason for avoiding insulating gaps in prestressed concrete relates to side-

flashing rather than to the ability of the reinforcement to carry a lightning discharge

to earth. See Clause 4.16.2 for details of the treatment of prestressed concrete in order

to avoid side-flashing. These principles should be used in the rare instance where

vertical prestressed elements, such as prestressed columns, occur in a building.

Although prestressed concrete affords a large reduction in the cross-sectional area of

steel reinforcement compared with conventionally reinforced concrete, calculations

indicate that prestressed cables of 10 mm diameter or more, will not be damaged

thermally by lightning and that thermal effects become negligible when several cables

are connected in parallel.

(d) Precast concrete Where electrical continuity is required through precast concrete

elements, the structural connection details, e.g. attachment plates, threaded ferrules,

bolt or dowel connections, should be carefully examined from an electrical continuity

standpoint. In most cases, the attachment device will be a metallic one and continuity

can be achieved by simply welding the attachment device to electrically continuous

reinforcement within the precast concrete element.

4.5.3 Structures with flammable or explosive atmosphere

Structures in which very small induced sparks present an appreciable element of danger,

such as structures containing explosive atmospheres of flammable vapour or gas and

structures in which easily ignitable fibres or materials producing combustible fines are

stored, e.g. cotton, grain or explosives, usually require much more than the standard

protection. Such structures can be protected by tall conducting masts earthed at the bottom,

by bonding as detailed in Clause 4.16.2.2, or by overhead earthed wires (see Section 7). Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 46: ASNZS 1768-2007

AS/NZS 1768:2007 44

COPYRIGHT

4.6 MATTERS TO BE CONSIDERED WHEN PLANNING PROTECTION

4.6.1 Structures to be erected

For structures that are to be erected, the matter of lightning protection should be considered

in the planning stage, as the necessary measures can often be effected in the architectural

features without detracting from the appearance of the building. In addition to the aesthetic

considerations, it is usually less expensive to install lightning protection during

construction than afterwards.

4.6.2 Design considerations

4.6.2.1 General considerations

The structure or, if the structure has not been built, the drawings, should be examined with

due regard to all the relevant details of this Standard and in particular to the following:

(a) Metal used in the roof, walls, framework or reinforcement above or below ground,

e.g. sheet piling, to determine the suitability of such metal in place of, or for use as,

components of the LPS.

NOTE: For a non-metallic roof, the position of any conduit, piping, water mains or other

earthed metal immediately beneath the roof should be noted, as this may inadvertently attract

a discharge if not shielded by an adjacent roof or structure, or downconductor on or above the

roof.

(b) Available positions for downconductors providing the required number of low

impedance paths from the air terminal network to the earth termination; this is

particularly important for internal downconductors.

(c) The nature and resistivity of the soil as revealed by trial bore holes for foundation

purposes or soil resistivity tests with, where economically practicable, the driving and

testing of a trial earthing electrode with the object of designing a suitable earth

termination.

(d) Services entering the structure above and below ground.

(e) Radio and television antennas and microwave communications antennae.

(f) Flag masts, roof level plant rooms, e.g. lift motor rooms, ventilating plant and boiler

rooms, water tanks and other salient features.

(g) The construction of roofs to determine methods of fixing conductors with special

regard to maintaining weatherproofing of the structure.

(h) Possible penetration of waterproofing membrane where earth terminations are to be

sited beneath the structure.

(i) The provision of holes through, or fixing to, reinforced concrete.

(j) The provision of bonding connections to steel frame, reinforcement rods or internal

metalwork, and for any holes through the structure, parapets, cornices, and the like, to

allow for the free passage of the lightning conductor.

(k) The choice of metal most suitable for the conductor, e.g. aluminium conductors for

structures where aluminium is employed externally.

(l) Accessibility of test joints; protection by non-metallic casing from mechanical

damage or pilferage and hazard to persons; lowering of flagmasts or other removable

objects; facilities for periodic inspection, especially on tall chimneys.

(m) The preparation of an outline drawing incorporating the foregoing details and

showing the positions of the main components to form a basis for the record drawing

recommended in Clause 8.4.

(n) Requirements for the coordination of the structure’s lightning protection earthing and

the earthing of electricity supply and telecommunications services.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 47: ASNZS 1768-2007

45 AS/NZS 1768:2007

COPYRIGHT

FIGURE 4.4 TYPICAL LPS USING METAL IN OR ON A STRUCTURE

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 48: ASNZS 1768-2007

AS/NZS 1768:2007 46

COPYRIGHT

FIGURE 4.5 TYPICAL LPS EMPLOYING VERTICAL AIR TERMINALS, FOR

PROTECTION LEVEL III

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 49: ASNZS 1768-2007

47 AS/NZS 1768:2007

COPYRIGHT

4.6.2.2 Route for conductors

Conductors should be installed with a view to offering the least impedance to the passage of

discharge current between the air terminals and earth. The most direct path is the best (see

Clause 4.12.2). The impedance to earth is approximately inversely proportional to the

number of widely separated paths, so that from each air terminal there should be as many

paths to earth as practicable. The number of paths is increased and the impedance decreased

by connecting the conductors to form a cage enclosing the building.

4.6.2.3 Trouble-free installation

Since an LPS, as a general rule, is expected to remain in working condition for long periods

with little attention, the mechanical construction should be strong, and the materials used

should offer resistance to corrosion.

4.6.2.4 Economy of installation

Economy of installation can be effected by keeping the variety of equipment to a minimum,

avoiding the use of unusual air terminal ornaments and similar features, and taking

advantage of constructional features as far as practicable.

4.7 MATERIALS

4.7.1 General

Copper is recommended for its conductivity and durability; however, alternative materials

may be used if suitable for the environment in which they are installed and are otherwise

satisfactory for the purpose (see Clause 4.8). Typical materials from which the current-

carrying component parts of LPSs may be chosen are given in Table 4.4 (see also

Clause 4.7.2).

Where insulating coatings are used, due regard should be given to their durability and non-

flammability.

For the protection of conductors at the tops of chimneys, see Clause 4.7.2.2(a).

4.7.2 Corrosion

4.7.2.1 Basic considerations

The materials used in LPSs should be resistant to corrosion resulting from the environment

in which they are installed. This includes the effects of atmospheric, soil or water-borne

electrolytes or contaminants, and of contact with those metals or alloys that will lead to

galvanic corrosion in the presence of moisture.

Corrosion resulting from contact of dissimilar metals can exist where a conductor is held by

fixing devices on or against external metal surfaces of a building or structure. Corrosion of

this nature can also arise where water passes over a relatively cathodic metal such as copper

carrying small amounts of copper corrosion product that is deposited as a fine film of

metallic copper on relatively anodic metals such as aluminium, zinc or steel. This causes

destructive galvanic corrosion of the latter metals, which are commonly used in building

cladding or roofing. The metallic components of the LPS should therefore be compatible

with the metals used externally on the structure over which these components pass or with

which they may make contact.

The components of LPSs may be constructed from a variety of materials as described in

Clauses 4.7.2.2 and 4.7.2.3.

4.7.2.2 Air terminals and downconductors

Specific recommendations for air terminals and downconductors are given in Clauses 4.11

and 4.12 respectively. Account should be taken of the principles outlined in Clause 4.7.2.1

in the selection of materials for those components. Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 50: ASNZS 1768-2007

AS/NZS 1768:2007 48

COPYRIGHT

Where there is a risk of metallic building elements being contaminated by corrosion

products, e.g. from copper conductors, the use of insulated conductors should be

considered. Such insulation may need protection against ultraviolet radiation, e.g. by

enclosure in conduit or by the application of appropriate paints or coatings.

Where insulated cables are used as downconductors, bonding to the air terminal network

should be effected at the specified intervals (see Clause 4.16.2.2) and bonding connections

should be sealed against the ingress of moisture.

Where structural steel or reinforcing bars form part of the downconductor system no further

corrosion-protection will normally be required.

With the common conductor materials, several specific precautions are necessary as

follows:

(a) Bare copper Copper should be of the grade ordinarily used for commercial electrical

work.

NOTE: Where any part of a copper conductor used in an LPS is exposed to the direct action

of chimney gases or other corrosive gases, it should be protected by a continuous coating of

tin, lead or other material suitable for the environment to which it is exposed. Such a coating

should extend not less than 500 mm below the top of a chimney or outside the area of

exposure. The coating should not be removed at joints.

(b) Bare alloys Galvanized iron or alloys of metals should be substantially as resistant to

corrosion as copper under similar conditions. Galvanized iron may be used as part or

the whole of the downconductor system provided it has adequate current-carrying

capacity and is fastened with fittings having compatible corrosion characteristics. The

galvanized iron may comprise the structural or decorative elements of the building

subject to these requirements.

(c) Bare aluminium or aluminium alloys Care should be taken not to use aluminium in

contact with concrete, mortar, the ground, or in other situations where moisture may

be retained causing the aluminium to deteriorate. Precautions should be observed at

connections with dissimilar metals.

In aluminium LPSs, copper, copper-covered and copper alloy fixtures and fittings

should not be used. Aluminium or aluminium alloy fixtures and fittings or

non-metallic components of adequate strength and durability are required. Special

arrangements will be needed at any earth terminations for this class of LPS.

Other materials may be used to the extent recommended elsewhere in this Standard.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 51: ASNZS 1768-2007

49 AS/NZS 1768:2007

COPYRIGHT

TABLE 4.4

TYPICAL MATERIALS FOR CURRENT-CARRYING COMPONENTS

Material Standard Grade or type

Castings

Leaded gunmetal

Aluminium alloy

AS 1565

AS 1874

C92410

EA401 or AA607

Bars and rods

Copper, hard-drawn or annealed

Phosphor-bronze

Naval brass

Aluminium bronze

Aluminium

Aluminium alloy

Galvanized steel

Stainless steel

AS/NZS 1567

AS/NZS 1567

AS/NZS 1567

AS/NZS 1567

AS/NZS 1866

AS/NZS 1866

110

518

464

627

1050

6063 or 6463A

Tubes

Copper

Galvanized steel

AS 1432 or NZS 3501

AS 1074

Strip

Copper, annealed

Aluminium

Galvanized steel

Stainless steel

AS 1566

AS/NZS 1866

AS 1397

ASTM A240M

110

1200

Stranded conductors

Copper, hard-drawn

Aluminium

Galvanized steel

Stainless steel

AS 1746 AS/NZS 5000.1

AS 1531 AS/NZS 5000.1

AS 1222.1

Fixing bolts and screws for copper

Phosphor-bronze

Naval brass

Aluminium bronze

Common brass

Stainless steel

AS/NZS 1567

AS/NZS 1567

AS/NZS 1567

AS 2738

518

464

627

272

Fixing bolts and screws for aluminium and

aluminium alloys

Aluminium alloy

Galvanized iron or steel

BS 1473

AS 1214

HB30

4.7.2.3 The earth termination network

The design of the earth termination network should assume that each earthing electrode will

be bonded, directly or fortuitously, to the following—

(a) the electrical installation earthing system and the MEN of the electricity supply

service (see AS/NZS 3000);

(b) the building structural steelwork or reinforcing material;

(c) any incoming service earth(s);

(d) any water, sewer and fire system supply pipes, if metallic; and

(e) any pipelines for gaseous or liquid fuels, if metallic.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 52: ASNZS 1768-2007

AS/NZS 1768:2007 50

COPYRIGHT

Some supply authorities attempt to isolate services (d) and (e) from (a), for galvanic

corrosion control reasons, by inserting insulating spacers at the pipe entry. Consideration

should be given to the fitting of SPDs across the insulating spacers, in consultation with the

supply authority, to prevent arc discharge without prejudicing the corrosion control

measures.

The earth termination network should be capable of satisfactory performance for the

expected life of the LPS under the corrosion conditions existing at the site when bonded

to—

(i) copper-based earthing systems (in most electrical installations);

(ii) steel-based structural material;

(iii) incoming service earths; which may be stainless steel, galvanized iron, copper or

lead; and

(iv) other metallic incoming services, e.g. steel or copper pipes for water or gas.

There are two hazards that arise from the bonding of other service earthing electrodes or

service lines to the MEN of the electricity supply service. Firstly, if the earthing system of

the electricity supply service is copper-based (as is mostly the case), it will cause

progressive galvanic destruction of less cathodic metals, such as steel, to which it is

connected. Secondly, the electricity supply service has many loads connected to it that

generate a direct current component; this direct current is an electrolytic hazard to other

earthing systems to which the electricity supply service earth is bonded. The amount of

direct current that can be generated by each appliance is limited by AS/NZS 3100, but it is

still sufficient to place at risk some types of earthing electrodes. In particular, steel rods

clad with copper or stainless steel suffer premature failure when a small amount of direct

current such as this perforates the cladding, initiating a process of self-destruction of the

rod core.

It will be clear that the selection of any common metal or alloy for the earth termination

network places either itself or other systems or services at some risk from galvanic

corrosion.

For lower-cost installations the use of one of the common metals or alloys may be

satisfactory. A list of these, with comments relating to their corrosion performance, is

provided in Table 4.5.

The extent to which the material combination ‘can be damaging’ is related to soil moisture,

the type and nature of electrolytes present, and area and resistance relationships. Inherently,

if such materials are used, a maintenance checking routine is essential.

NOTE: For further information see Paragraph C9, Appendix C.

Where soil conditions are particularly aggressive from a corrosion viewpoint (soil

resistivity typically below 30 Ω.m, especially if combined with a pH value of less than 5.5),

such as may exist in reclaimed marine areas, the use of an inert anode material (see

AS 2832.1) may be necessary. Expert advice on the selection of an appropriate earth

termination network should normally be sought where such soil conditions exist.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 53: ASNZS 1768-2007

51 AS/NZS 1768:2007

COPYRIGHT

TABLE 4.5

CORROSION PERFORMANCE OF COMMON METALS AND ALLOYS

USED AS EARTHING ELECTRODES

Metal/alloy

Deleterious effect of this

metal/alloy on other bonded

underground ferrous metals

Deleterious effect on this metal/alloy from

bonding to MEN (copper-based) systems

Galvanized iron or steel Nil Damaging

Solid copper Damaging Nil

Copper-clad steel Damaging Can be damaging—may be acceptable

Solid stainless steel or nickel

iron alloy

Generally acceptable Can be damaging—may be acceptable

Stainless-steel-clad steel Generally acceptable Can be damaging

Bronze Generally damaging May be acceptable

Brass Can be damaging May be acceptable—can be dezincified

Zinc Nil Damaging

Aluminium Nil Extremely damaging

Magnesium Nil Extremely damaging

4.8 FORM AND SIZE OF CONDUCTORS

4.8.1 Factors influencing selection

The form and size of the conductors of the LPS should be selected having regard to their—

(a) electrical and thermal characteristics (see Clause 4.8.2); and

(b) mechanical strength, if required, and the likelihood of corrosion (see Clause 4.8.3).

The minimum cross-sectional area required of a main current-carrying component of a

LPS is 35 mm2. The dimensions of typical conductors are given in Table 4.6.

4.8.2 Electrical and thermal considerations

Air terminals, downconductors and other conductors of the LPS that may carry the full

lightning current, should have a cross-sectional area and electrical conductivity such that

they are able to carry the expected current without deterioration and without attaining

temperatures that may give rise to risk of fire. Copper conductors having a cross-sectional

area of not less than 35 mm2 will normally be necessary for this purpose. Conductors of

other materials may be used provided they satisfy the above criteria for current-carrying

capacity and temperature rise. (For further details, see Table 4.6).

Conductors, which because of their arrangement in the LPS, will carry only a proportion of

the lightning current, may have a cross-sectional area that is proportionately reduced but

should be not less than one-fifth of the cross-sectional area needed to carry the full

lightning current, or 6 mm2, whichever is the greater.

Conductors of larger cross-sectional area than recommended above may be needed as

indicated in Clause 4.8.3.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 54: ASNZS 1768-2007

AS/NZS 1768:2007 52

COPYRIGHT

4.8.3 Mechanical strength and corrosion considerations

Conductors of larger cross-section than those recommended in Clause 4.8.2 may be needed

where—

(a) a significant reduction of cross-sectional area is likely to be experienced in service

due to the effects of corrosion; or

(b) an increase in cross-sectional area or section of different shape (e.g. tubular instead of

solid) is required to provide adequate mechanical strength, e.g. for air terminals (see

Clause 4.11.1).

Consideration should also be given to the use of a larger cross-sectional area than that

recommended in Clause 4.8.2 in situations where inspection or repair of the conductor is

unusually difficult.

4.9 JOINTS

4.9.1 Effectiveness of joints

The LPS should have as few joints as possible. Joints and bonds should be mechanically

and electrically effective, e.g. clamped, screwed, bolted, crimped, riveted or welded. Where

overlapping joints are used, the length of the overlap should be not less than 20 mm for all

types of conductor. Contact surfaces should first be cleaned then inhibited from oxidation

with a suitable corrosion-inhibiting compound.

All mechanical connections should be inspected on a regular basis in accordance with

Section 8 to ensure the integrity of the connection over time.

4.9.2 Protective covering

Joints and bonds may be protected with bitumen or embedded in a plastics compound

according to the local conditions. Particular attention should be given to joints of dissimilar

metals.

4.10 FASTENERS

Conductors should be securely attached to the building or other object upon which they are

placed. Fasteners should be substantial in construction and not subject to breakage, and

should be, together with the nails, screws, or other means by which they are fixed, of the

same material as the conductors, or of such nature that there will be no serious tendency

towards galvanic corrosion in the presence of moisture because of contact between the

different parts.

Fasteners should be spaced so as to give adequate support to the conductor.

Downconductors should be fastened at spacings not exceeding 1.0 m on horizontal runs and

not exceeding 1.5 m on vertical runs.

The method of fastening should not result in a reduction of the conductor cross-section

below the minimum recommended in Clause 4.8.

NOTE: Plastics materials may be used for the fixing of conductors provided such materials are

suitable for long-term exposure to the outdoor environment (e.g. stabilized against the harmful

effects of ultraviolet radiation) and otherwise satisfy the recommendations of this Clause.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 55: ASNZS 1768-2007

53 AS/NZS 1768:2007

COPYRIGHT

TABLE 4.6

TYPICAL SECTION DIMENSIONS OF MAIN CURRENT-CARRYING

COMPONENTS

Component Typical section dimensions

Air terminals

Strip 25 mm × 3 mm

Rods 10 mm dia.

Stranded conductors 35 mm2

Downconductors

Strip 25 mm × 3 mm

Rods 10 mm dia.

Stranded conductors 35 mm2

Galvanized materials 35 mm2

Earthing electrodes and buried conductors

Earth rods 12 mm dia.

Galvanized star stakes (star pickets) Y – 25 mm × 19 mm × 19 mm

Galvanized steel water pipe 25 mm dia.

Galavanized steel strip 50 mm × 3 mm

Copper strip 25 mm × 3 mm

Stranded conductor 70 mm2

Main current-carrying bonding conductors

Strip 25 mm × 3 mm

Cable 35 mm2

4.11 AIR TERMINALS

4.11.1 General requirements

An air terminal may consist of a vertical rod as for a spire, a single horizontal conductor as

on the ridge of a small dwelling, or a network of horizontal conductors with vertical rods

for the protection of roofs of large horizontal dimensions (see Figure 4.5). Protection may

also be provided with a horizontal overhead wire supported, if necessary, independently of

the building to be protected or by a vertical air terminal network (see Figures 4.2 and 4.3).

Salient points of the structure should be incorporated in the air terminal network.

The upper portions of the downconductors on tall buildings should be regarded as a

continuation of the air terminal network and should be positioned so as to intercept side

strikes to the building. Preference should be given to placing downconductors as near as

possible to the exposed outer vertical corners of a building.

All metallic projections, on or above the main surface of the roof, should be bonded to, and

form part of, the air terminal network. In the case of telecommunications antennas, which

have to be insulated from earth, a spark gap connection to earth or an SPD should be

provided.

Where roof construction consists of electrically continuous metallic materials, such metallic

roofs may form part of an LPS, obviating the need for air terminals.

If portions of a structure vary considerably in height, any necessary vertical air terminal or

air terminal network of the lower portions should, in addition to their own downconductors,

be bonded to the downconductors of the taller portions (see Figures 4. 4 and 4.5).

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 56: ASNZS 1768-2007

AS/NZS 1768:2007 54

COPYRIGHT

Air terminals may be of any form provided the section used and the means of attaching it to

the building structure have adequate mechanical strength to withstand the expected wind

loading and natural harmonic resonances. Vertical air terminals of greater than three metres

in height will generally need a form of additional fixing using brackets, bracing or guy

wiring for suitable support.

4.11.2 Protection of roofs

The parts of roofs most likely to be struck by lightning are parapets, the corner and edges of

flat roofs, chimneys, and the ridges and eaves of sloping roofs. Preference should be given

to positioning the air terminals so as to protect these highly exposed parts.

The height of a vertical air terminal should be such that the tip will be not less than 500 mm

above the object to be protected. On large flat and gently sloping roof areas a number of

vertical rods of greater than 500 mm in height may be needed to establish a zone of

protection over the whole roof area in accordance with Clause 4.4.

Horizontal conductors such as strap or cable on parapets and metallic objects such as

architectural features, flagpoles, metal railings, steel plant surrounds and roof access

ladders may be used as air terminals to protect a planar roof surface. When positioned at a

height of not less than 500 mm above the area to be protected and in accordance with the

design rules (see Clause 4.3) and the RSM (see Clause 4.4.2), the conductors or objects will

be at a suitable height to achieve the selected interception efficiency.

In special circumstances, such as where it is desired to preserve the appearance of a historic

building, horizontal air terminals may be installed immediately underneath the cladding

(e.g. tiles) of a non-conductive roof. However, it should be noted that, in the event of a

lightning strike to the roof, the cladding will be punctured and may suffer some damage.

Horizontal and vertical air terminals and interconnecting conductors of the air terminal

network should be located so as to constitute, as nearly as local conditions permit, an

enclosing network that joins each air terminal to each other and to all downconductors.

All metallic objects at roof level such as sheeting, plant, plant screens, tanks, gutters,

walkways, ladders, antennas, masts, poles, vents, chimneys, conduits, piping, cable tray,

enclosures, etc should be bonded to the air termination network.

4.11.3 Protection of the sides of tall buildings

4.11.3.1 Influence of forms of construction

The consequences of a strike to the sides of a building may result in damage of a minor

nature. Unless there are specific reasons for side protection, as would be the case with a

structure containing explosives, it is considered that the cost of side protection will not

normally be justified.

Many buildings will have perimeter columns in which the reinforcement (or structural steel)

is used as a part of the downconductor system. Where these columns on the external facade

are no further than 20 m apart, no further protection will be required in respect of strikes to

the side of the building.

In the event of a strike to such a column or to isolated metal components such as small

window frames, it is likely that a small section of masonry cladding material may be

dislodged.

Where the risk of this is unacceptable, conductors should be installed on the external faces

of the columns to receive the strikes. These conductors will take the form of lightning air

terminals/downconductors and should be bonded at the bottom into the LPS.

Where side protection is a requirement of an LPS and suitable columns do not exist to

receive strikes to the sides of buildings, vertical conductors should be installed for this

purpose. These conductors should be spaced around the perimeter of the building at

intervals not exceeding 20 m. Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 57: ASNZS 1768-2007

55 AS/NZS 1768:2007

COPYRIGHT

4.11.3.2 Curtain wall construction

It has become commonplace for tall buildings to have external glass curtain walls, with the

curtain wall external to perimeter columns. The majority have major glass elements

contained (and restrained) within a metallic framework. This framework is often inherently

connected, electrically, to the metal in the building structure via the standard connection

details used to mechanically fix the curtain wall structure to the structural frame of the

building itself.

Where this inherent connection occurs and where the frame of the building is incorporated

into the LPS, no further bonding of the curtain wall to the LPS is necessary.

In other cases, the curtain wall metal framing shall be bonded into the LPS at roof and

ground level. It is essential that bonding be undertaken at the corners of the structure and

around the perimeter of the building at intervals not exceeding 20 m. (See Clause 4.16.2.2

for further details).

4.12 DOWNCONDUCTORS

4.12.1 Structures—General

Downconductors should be installed at each external corner of the building and additional

downconductors installed, as necessary, at spacings not exceeding 20 m.

4.12.2 Route

The route followed by downconductors should be in accordance with the following

recommendations:

(a) Downconductors should be distributed around the outside walls of the structure. It is

undesirable to locate downconductors in areas where persons are liable to congregate.

The walls of light wells may be used for fixing downconductors, but lift shafts should

not be used for this purpose.

(b) Where the provision of suitable external routes for downconductors is impracticable

or inadvisable, e.g. buildings of cantilever construction from the first floor upwards,

downconductors may be housed in an air space provided by a non-metallic,

non-combustible internal duct. Any covered recess or any vertical service duct

running the full height of the building may be used for this purpose, provided that it

does not contain any unarmoured or non-metal-sheathed service cable (see

Clause 4.16.2.3).

(c) Any extended metal running vertically through the structure should be bonded to the

lightning downconductor at the top and bottom unless the clearances are in

accordance with Clause 4.16.

(d) A downconductor should follow the most direct path possible between the air

terminal and the earth termination. Right angle bends may be used when necessary

but deep re-entrant loops should be avoided.

(e) A structure on bare rock, protected in accordance with Clause 4.14.3.1, should be

provided with at least two downconductors equally spaced.

NOTE: The positioning and spacing of downconductors on large structures has often to be

decided in practice by architectural considerations. However, their number should be governed by

the recommendations above.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 58: ASNZS 1768-2007

AS/NZS 1768:2007 56

COPYRIGHT

It is now recognized that sharp bends in a downconductor, such as occur at the edge of a

roof, do not significantly impede the discharge of a lightning current, nor are the

mechanical forces produced by a lightning current likely to endanger the conductor or its

fixings. In contrast, re-entrant loops in a conductor can produce high inductive voltage

drops so that the lightning discharge may jump across the open side of the loop. As a rough

guide it can be stated that this risk may arise when the length of the conductor forming the

loop exceeds 8 times the width of the open side of the loop. It follows from the above that

there is no need to round the path of the downconductors at the edge of a roof and that an

upturn within the limits stated is acceptable. Where large re-entrant loops as defined cannot

be avoided, e.g. for some cornices or parapets, the conductor should be arranged in such a

way that the distance across the open sides of the loop complies with the principles given

above. Alternatively, such cornices or parapets should be provided with holes through

which the conductor can pass freely. (See Figures 4.6 and 4.7).

An exception to the above practice is necessary for a building cantilevered out from the first

storey upwards. The downconductors in this case should be taken straight down to the

ground since, by following the contour of the building, a hazard could be created to persons

standing under the overhang formed by the cantilever. In such a case, the use of internal

ducts for downconductors is recommended (see Figure 4.8).

FIGURE 4.6 GENERAL PRINCIPLES OF A RE-ENTRANT LOOP

IN A CONDUCTOR TAKEN OVER A PARAPET WALL

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 59: ASNZS 1768-2007

57 AS/NZS 1768:2007

COPYRIGHT

FIGURE 4.7 ACCEPTABLE METHOD OF TAKING A CONDUCTOR THROUGH A

PARAPET WALL

FIGURE 4.8 ROUTES FOR DOWNCONDUCTORS IN A BUILDING WITH

CANTILEVERED UPPER FLOORS

4.12.3 Mechanical damage

Where any part of an LPS is exposed to mechanical damage it should be protected by

covering it with moulding or tubing preferably of non-conductive material. If metal is used,

the conductor should be electrically connected to both ends of the protective covering.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 60: ASNZS 1768-2007

AS/NZS 1768:2007 58

COPYRIGHT

4.13 TEST LINKS

Where practicable, test links should be provided to enable the continuity of each individual

parallel path of the lightning conductor system to be measured.

Where a driven or buried earthing electrode is provided as part of the LPS, test links should

be provided to permit measurement of the resistance of the individual earth terminations, in

such a position that, while not inviting unauthorized interference, is convenient for use

when testing. Such resistance measurements are indicative only and provide the basis of

comparison to determine whether any deterioration in the earth termination network has

occurred in service (see also Appendix C).

4.14 EARTH TERMINATIONS

4.14.1 General principles

Each downconductor should be connected to an earthing electrode or to the earth

termination network. The design of earth terminations should be such that lightning currents

are discharged into the earth in a manner that will minimize step and touch potentials and

the risk of side-flashing to metal in or around a structure. This can be achieved by ensuring

that the potential with respect to the general mass of the earth at each earth termination is

limited by a sufficiently low resistance to earth, so that the discharged current flows in as

close to uniform manner as possible in all directions away from the structure.

Ionization of the soil near an earthing electrode carrying lightning current tends to reduce

the potential of the earthing electrode relative to remote earth to a lower value than the

potential that would be calculated using the earth resistance measured at low currents.

Appendix C provides information on the effectiveness of various forms of earth termination

networks for lightning protection purposes and on the associated calculation/measurement

procedures.

4.14.2 Earthing resistance

4.14.2.1 Basis for measurements

The term earthing resistance is used in this Clause and elsewhere in this Standard because

the most common measuring instruments available are low frequency devices. A more

appropriate measurement for lightning protection purposes is that of earth impedance and

such measurements are preferred when suitable high frequency or impulse type instruments

are available.

4.14.2.2 Recommended values

In general, the whole of an interconnected LPS should have an earthing resistance not

exceeding 10 Ω before any bonding is effected to services that are not part of the LPS. In

addition, each earthing electrode of an interconnected LPS that is not interconnected at or

below ground level should have an earthing resistance not exceeding the product obtained

by multiplying 10 Ω by the number of downconductors.

NOTE: Where the installation has two or more air terminal networks not directly interconnected,

such as a twin-tower building, then for the purpose of determining the required earthing

resistance, it should be considered as consisting of separate LPSs.

Where buildings are primarily used for telecommunications services or information

technology installations, or installation of multiple items of other sensitive electronic

equipment, an earthing resistance not exceeding 5 Ω should be required.

A reduction of earthing resistance can be achieved by extending or adding to the earth

termination network or by interconnecting the individual earth terminations of

downconductors.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 61: ASNZS 1768-2007

59 AS/NZS 1768:2007

COPYRIGHT

Notwithstanding the above recommendations, earthing electrodes complying with either of

the following, need not comply with the 10 Ω criterion:

(a) For a substantial structure effectively encircled by a buried earthing electrode, an

earthing resistance not exceeding 30 Ω should be satisfactory. A buried earthing

electrode covering at least three sides of the structure may be regarded as effectively

encircling the structure.

(b) For any system incorporating two or more downconductors, it should not be necessary

to install a total length of more than 50 m of widely separated horizontal or vertical

earthing electrodes per downconductor, regardless of the earthing resistance.

Where reinforced concrete footings are used as earthing electrodes for a building,

compliance with the recommended maximum resistance values should be determined by the

measurement of resistance of typical footings that support the building structure. The

measurements should be made at the stage of building construction when the footings are

structurally isolated and may be treated as independent earthing electrodes.

4.14.3 Common earthing electrode and potential equalization

4.14.3.1 Common earthing electrode

Where conditions permit potential equalization techniques to be used, a common earthing

electrode may be installed to serve the LPS and other appropriate services. The earthing

electrode should comply with the recommendations in this Standard and with any

regulations that may govern the appropriate services (for telecommunications services, see

Clause 4.14.3.2). The earthing resistance should be the lowest required by any of the

regulations for such services.

Where isolation is required, a common earthing electrode should not be used, but the

separate earthing electrodes should be bonded via an SPD to minimize potential differences

between the LPS earth termination network and other earthing systems in the event of a

lightning strike.

4.14.3.2 Communications earths

Where a communications earth is installed at a dwelling or similar small building, that earth

should be connected to other earths present (see Paragraph B5.6, Appendix B). However,

where a communications earth, such as a Telecommunications Functional Earthing

Electrode (TFEE), is required to be isolated from other earths, because of noise or direct

current conduction considerations, this earth should be bonded through a normally non-

conducting protector or SPD.

4.15 EARTHING ELECTRODES

4.15.1 General considerations

An earthing electrode may be of any type provided—

(a) it achieves a low resistance to the general mass of earth, as recommended in this

Standard;

(b) it has adequate mechanical strength and corrosion resistance to ensure that the desired

service life will be achieved when installed in the environment concerned; and

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 62: ASNZS 1768-2007

AS/NZS 1768:2007 60

COPYRIGHT

(c) it has adequate current-carrying capacity for the discharge of lightning currents

without sustaining damage that might jeopardize its continued effectiveness.

NOTES:

1 Electrode earthing resistance may be measured by standard methods (see Paragraph C10,

Appendix C).

2 If the soil resistivity is known, the electrode earthing resistance may be calculated as

shown in Paragraph C3, Appendix C. It should be noted, however, that such calculations

are only approximate and it is important that the electrode earthing resistance should in

fact be determined by field test.

3 It is fairly easy to determine soil resistivity by test as set out in Paragraph C10.1,

Appendix C.

The selection and design of the earth termination network should therefore take account of

the following:

(i) Soil resistivity.

(ii) The corrosion aggressiveness of the soil.

(iii) The physical structure of the soil (rocks, obstructions and other services).

(iv) The corrosion compatibility of the earth termination network with other structures to

which it will be, or may become, bonded.

(v) The options available for installation at the site (trenching, driving, drilling, land

excavation or use of structural metalwork).

(vi) The effects that it may have on other systems (electrical or telecommunications).

If the structure has a reinforced concrete floor and/or footings (see Clause 4.5.2), it may not

be necessary to install lightning protection earthing electrodes, (see Clauses 4.5.2.4 and

Paragraph C8, Appendix C). Generally speaking, the impedance to earth of a reinforced

concrete floor and footings will be lower than that of an earth termination system utilizing

vertical earthing electrodes.

4.15.2 Connections to earthing electrodes

4.15.2.1 Mechanical protection

Where conductors that are connected to earthing electrodes are accessible, such conductors

and connections should be protected against mechanical damage and vandalism.

Where conductors connecting driven earthing electrodes in parallel are not installed above

the ground, they should be buried not less than 500 mm below the surface.

4.15.2.2 Selection of materials

Care should be exercised in the selection and application of materials for connections to

earthing electrodes to avoid the possibility of galvanic corrosion, e.g. because of

differences between the materials of such connections and the earthing electrodes.

4.15.2.3 Joints

Joints between earthing conductors and earthing electrodes should be of adequate strength

and current-carrying capacity, and be arranged so as to ensure that there will be no failure

of the connection under conditions of use or exposure that can reasonably be expected. For

suitable methods, refer Clause 4.9.

4.15.2.4 Test links

If test links are inserted in earthing conductors connected to earthing electrodes, they

should be secured in the closed position and be arranged so that the opening of any one link

does not interfere with earth connections other than the one under test.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 63: ASNZS 1768-2007

61 AS/NZS 1768:2007

COPYRIGHT

4.15.3 Inspection and testing of earthing electrodes

The earthing resistance of electrodes should be determined by test both at the time of

installation and regularly during the life of the installation.

For details of inspection and testing, see Section 8.

4.16 METAL IN AND ON A STRUCTURE

NOTE: The term ‘metal in or on a structure’ includes all metal such as reinforcement rods and

bars, pipes, conduits, chimneys, corrugated iron, roof sheeting, rails, ladders, screens, sunshades,

etc. Metal hidden from view should not be overlooked. Tubing, containing electrical conductors

or metal-sheathed cables, is, for instance, often embedded in an external wall and may be quite

close to the LPS.

4.16.1 Use of metal in or on a structure as a part of the lightning protection system

Where a structure contains electrically continuous metal, e.g. continuous steel frame, or

metal within a roof, wall, floor or covering, this metal suitably bonded in accordance with

Clause 4.16.2.2 may be used as part of the LPS, provided that the amount and the

arrangement of the metal render it suitable for use, as recommended in Clauses 4.11 to 4.15

inclusive.

Where a structure is simply a continuous metal frame without external metal covering e.g.

tower pole, it requires no air terminal or downconductor; it is sufficient to ensure that the

conducting path is electrically continuous and that the base is adequately earthed.

A steel frame structure or reinforced concrete structure may have foundations with

sufficiently low inherent earthing resistance and, if connections are brought out from the

reinforcement, a test may be made to verify its suitability for use as part of the LPS (see

Clause 4.15.1).

4.16.2 Prevention of side-flashing

4.16.2.1 Methods of prevention

When an LPS is struck, its electrical potential with respect to earth is raised and, unless

suitable precautions are taken, the discharge may seek alternative paths to earth by side-

flashing to other metal. Two methods exist to prevent side-flashing: bonding and isolation.

Bonding is the procedure whereby metal parts are positively connected to one another so as

to prevent inadvertent electrical connection occurring due to side-flash. Isolation is the

separation or insulation of metal parts in such a way that electrical breakdown or side-flash

to them is prevented. Isolation may be achieved by separation of the LPS from the structure

protected or by separating metal parts and services in a non-conductive structure from the

LPS.

Bonding effectively eliminates any local potential difference between the metal parts that

are bonded together. However, it is possible to obtain large potential differences for very

short times between adjacent metallic objects that are connected together at a remote

location. These potential differences could be hazardous if the bonding system is

inadequate. Many structures can be effectively bonded so as to eliminate any hazard,

however, care should be taken to prevent subsequent installation of a metallic service

creating a hazard. It should be noted that any conductive element that is bonded into the

LPS can be expected to carry a proportion of the lightning current. Therefore, the bond and

bonded element should be capable of carrying such current. (Refer to Table 4.6 for typical

dimensions of bonding conductors).

With isolation, it is often difficult to obtain and to maintain the necessary safe clearances,

and to prevent connection of an ‘isolated’ LPS back to the structure via earth and buried

metallic services. To achieve isolation it may be necessary to utilize a protection system

that is completely separate from the protected structure, and is remotely earthed. Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 64: ASNZS 1768-2007

AS/NZS 1768:2007 62

COPYRIGHT

If the structure is constructed with conductive materials such as reinforced concrete or steel

frames, isolation of a protection system mounted on the structure requires the use of high

impulse strength, high voltage insulation.

In general, where the LPS is mounted on the structure, isolation can only be achieved at low

cost if the structure is small.

4.16.2.2 Bonding

The conditions under which bonding should be effected are as follows:

(a) Where practicable, all structural steel and metallic reinforcement in a structure, if not

used as a part of the LPS, should be bonded to that system (and hence become part of

that system).

As indicated in Clause 4.5.2.4(b), metal rods in in situ reinforced concrete may be

considered to be electrically continuous. Consequently, bonding may be achieved

with a reasonable number of connections to the rods, a bonding connection to each

rod being unnecessary.

Where prestressed or post-tensioned concrete elements are involved, it has been

found that the stressing cables frequently remain electrically isolated from other

structural metal at the completion of the stressing process. Such cables should be

bonded at both ends to the LPS, particularly where the structural element is exposed

to the weather.

NOTE: This bonding is recommended, not out of concern for a side-flash causing immediate

structural damage, but rather to avoid the chance of the side-flash causing cracking of the

corrosion-protecting concrete grout used around the cable. Prestressed cables under stress are

highly susceptible to corrosion.

Where metal exists in a structure, such as reinforcement in a precast concrete

spandrel panel or post-tensioned concrete slab, which cannot be bonded into a

continuous conducting network and which is not or cannot be equipped with external

earthing connections, its presence should be disregarded. The hazard presented by the

presence of such metal should be minimized by keeping it entirely isolated from the

LPS, which includes consideration of the numbers of downconductors.

(b) Where the roof structure is wholly or partly covered by metal, care should be taken

that such metal is provided with a continuous conducting path to earth.

(c) Metal that is attached to the outer surface of a structure should preferably be bonded

as directly as possible to the LPS. Where bonding is difficult and where the

consequences of side-flashing to isolated metalwork is not considered serious,

bonding may be omitted.

Where such metal has considerable length, e.g. cables, pipes, gutters, stairways, and

runs approximately parallel to a downconductor or column, it should be bonded to the

LPS at each end and at vertical intervals of not more than 20 m.

(d) In curtain wall construction, where the framework would otherwise be electrically

isolated, the frame should be made electrically continuous and should be bonded to

the LPS at intervals not exceeding 20 m around the perimeter of the building. This

should occur at the top and bottom of each curtain wall and at levels separated by not

more than 20 m vertically, including those sections that are less than 45 m above

ground.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 65: ASNZS 1768-2007

63 AS/NZS 1768:2007

COPYRIGHT

(e) Where there is insufficient clearance from the LPS, metal entering or leaving a

structure in the form of sheathing, armouring or piping for electricity supply, gas,

water, telephone, steam, compressed air or other services, should be bonded as

directly as possible to the earth termination at the point-of-entry or exit outside the

structure. In this operation, the appropriate Standards and any regulations that may

apply to such services should be observed.

(f) Masses of metal in a building, such as a bell-frame in a church tower, should be

bonded to the nearest downconductors by the most direct route available.

4.16.2.3 Isolation

The necessary separation distance from any point on the LPS depends on the electric

potential, or voltage, generated at that point by the lightning discharge.

To achieve a sufficiently low probability of side-flash, the responses of the protection

system to a range of severe stroke current waveshapes have to be considered. Because the

time for a lightning stroke current waveshape to significantly change its steepness is similar

to the time taken by the incident wave to travel from the point of strike to the earth

termination, travelling wave techniques are used to calculate the voltage waveforms

generated. However, an approximate voltage waveform sufficient to estimate the required

separation distance can generally be calculated from the resistive and inductive voltage

drops in the system.

Isolation may be provided by appropriate air clearance from bare metal downconductors or

by appropriately insulated downconductors. The requirements for insulated downconductors

are detailed in IEC 62305.3.

NOTE: Appendix D gives examples of calculation procedures.

For conventional LPSs using typical bare metal downconductors, the separation distance in

air at a given point on the protection system is required to be not less than D, where D, in

metres, is the greater of D1 and D2 as defined below and shown in Figure 4.9:

(a) D1—is the required clearance associated with the discharge voltage of the design first

stroke of a severe lightning flash and takes account of the design maximum lightning

current. D1 is defined only for H/n < 30.

(b) D2—is the required clearance associated with the discharge voltage of the design

subsequent stroke of a severe lightning flash and takes account of the design

maximum steepness of the current wavefront.

To take account of systems with a common earthing electrode it is necessary to separate D1

into two components as follows:

D1 = Di + De . . . 4.16.2.3

where

Di = 30for,

12<

n

H

n

H

De = 0.3R

H = length of downconductor from the point considered to earth, in metres

n = number of downconductors connected to a common air terminal

R = combined earthing resistance of the LPS, in ohms

Di is the component of the first stroke separation distance associated with potential

difference generated within the structure.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 66: ASNZS 1768-2007

AS/NZS 1768:2007 64

COPYRIGHT

De is the component of the first stroke separation distance associated with local EPR, and is

independent of the point on the LPS considered. This term is applicable to any remotely

earthed objects, such as services entering the building, that do not share a common earthing

electrode with the LPS, and to any long unearthed objects within a relatively

non-conductive structure. Where a common earthing electrode in accordance with

Clause 4.14.3 is used, the term De may be neglected (R = 0 in Figure 4.9). Where it is

applicable, the clearance De should be maintained throughout the structure and thus

determines the minimum separation distance at the base of the structure.

The required clearance for steep-fronted surges, D2, may be read from the dotted curve

given in Figure 4.9. As the separation distance D2 varies with the length of downconductor

from the point considered to earth, D2 normally determines the required separation in the

upper parts of tall structures.

The shortest separation distance over the surface of non-conductive structural material

should be 2D for protected dry surfaces and 3D for external surfaces. The separation

distance through solid non-conductive structural material should exceed 0.5D.

NOTES:

1 For a substantial reinforced or structural steel frame building that utilizes the structure as part

of the LPS, the separation distance may be obtained from Figure 4.9 by taking n to be 1.5

times the number of reinforced or steel columns. The term De may be neglected for these

buildings by assessing D for R = 0, except when considering remotely earthed services

entering the building.

2 The extent to which uninsulated services may be considered to be affected by local EPR can

be determined by a test in which a known current is injected into the LPS and potential

differences to the electrical installation earthing system are surveyed.

FIGURE 4.9 REQUIRED SEPARATION DISTANCES IN AIR

4.16.2.4 Effects of bonding on cathodically-protected metal

In the bonding of adjacent metalwork to the LPS, careful consideration should be given to

the possible effects such bonding would have upon metalwork that may be cathodically-

protected (see AS 2832 series).

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 67: ASNZS 1768-2007

65 AS/NZS 1768:2007

COPYRIGHT

4.16.2.5 Bonding of underground services

In the ground, bonding between the LPS earth termination network of any structure and

buried metallic service pipes is essential, unless the service can be effectively isolated. If

this is not done, an electrical breakdown can occur through the soil between these systems

and the resulting electric arc can cause structural damage or may puncture a service pipe

(see also Clause 4.16.2.2 (e)) SPDs may usually be fitted where direct connection is

unacceptable.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 68: ASNZS 1768-2007

AS/NZS 1768:2007 66

COPYRIGHT

S E C T I O N 5 P R O T E C T I O N O F P E R S O N S A N D

E Q U I P M E N T W I T H I N B U I L D I N G S

5.1 SCOPE OF SECTION

This Section sets out recommendations for the protection of persons and equipment within

buildings from the effects of lightning. The provision of an LPS for the building structure

will not automatically guarantee such protection. These recommendations may be applied

irrespective of whether an LPS for the building structure is provided in accordance with

other sections of this Standard. The recommendations principally consist of installation of

equipotential bonding of services, conductive parts, earthing systems, and the provision of

SPDs as appropriate on services.

5.2 NEED FOR PROTECTION

Whilst persons and equipment within buildings may be protected from a direct lightning

strike, many circumstances arise where the effects of lightning are transmitted within the

building, by various means as described below, placing persons and equipment at risk.

Communications and electronic equipment are particularly susceptible to damage from

lightning impulses and such damage may occur at energy levels well below those needed to

cause injury to persons. In addition, there is a significant fire risk associated with impulse

failure of many types of electrical and electronic equipment.

Installation of protective measures, including primary and/or secondary SPDs on services,

depends on many factors which may be included in an appropriate risk assessment.

From a telecommunications perspective, AS 4262 provides a method to determine when

protection is required (AS 4262.1 for person protection and AS 4262.2 for equipment

protection). Further information on protection of customer premises may be found in ITU-T

Recommendation K.66.

5.3 MODES OF ENTRY OF LIGHTNING IMPULSES

There are four principal modes of entry of lightning impulses into buildings, as described

below and shown in Figure 5.1, and these may occur separately or in combination. The

modes are:

(a) Directly by the interception of lightning on exterior metalwork Lightning impulses

may be transmitted in the interior of the building as a consequence of a strike to

exterior metal that has a direct conductive connection to the interior of the building,

e.g. via telecommunications antennas, plumbing fittings and the like. This mode of

entry is characterized by a series path for the full impulse energy and is capable of

conveying the full destructive effect of the lightning discharge. The waveshape of the

lightning impulse is usually not significantly modified.

(b) Indirectly by the interception of lightning on other structures or services A lightning

strike to other structures or services that have conductive connection to the building,

e.g. the low-voltage electricity distribution system or other services, may result in an

impulse being transmitted into the building. The impulse is characterized by a lower

energy level compared to that involved in Item (a), being a parallel path to the

interior of the building served by the low-voltage mains. It is an EPR effect caused by

the lightning impulse passing to earth through the neutral/earth connection and

resulting in a increase in potential because of the impedance of the earth termination

network.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 69: ASNZS 1768-2007

67 AS/NZS 1768:2007

COPYRIGHT

The magnitude of the impulse at the structure is governed by the neutral/earth

impedance at the interception point, the length of the service line, the number of

earthing features per unit length on the line adjacent to the interception point and,

lastly, the electrical characteristics of the lightning discharge.

Where a combined MEN electricity supply service exists (high voltage earth bonded

to low-voltage earth), the regulatory authorities require an earthing resistance of not

more than 1 Ω. As might be expected this limits the EPR impulse voltage

considerably. In addition, in urban areas the number of electricity supply services

with an earth (i.e. neutral/earth) connection is considerable, perhaps 100 per km.

Consequently, the EPR lightning impulse is rapidly reduced, perhaps to insignificant

levels in about 60 m. On the other hand, sparsely settled areas with distribution

systems other than the MEN type can give rise to high EPR values that may not

reduce to safe levels for some hundreds of metres.

The impulse wave is normally modified by the transmission path in the EPR mode by

distributed electrostatic capacity and transmission line effects. This reduces the

severity of the impulse but prolongs the time that the protection equipment must

conduct the pulse to earth.

Although the energy levels involved in an EPR impulse are substantially less than

those that apply for Item (a), they may still be of a high order. Based on sparks or

arcs observed in incidents involving personal injury or equipment damage under EPR

conditions, voltages of the order of 100 000 V are not uncommon and cases involving

voltages of about 1 000 000 V have been observed. Impulse currents in this mode can

range from a few amperes to several thousand amperes.

It should be noted that EPR conditions can arise singly or as a combination of

occurrences. In addition to lightning intercepting the overhead low-voltage electricity

distribution system, other lightning leaders may intercept trees, clothes lines, sheds or

other nearby structures, giving rise to a quite complex overall EPR condition.

NOTE: Of the lightning incidents involving electrical equipment that have been investigated

by Telstra, some 80 percent can be attributed to the entry mode described in the preceding

paragraphs.

(c) Inductively by electric and magnetic field coupling In general, this mode of entry

happens more frequently but involves lower energy levels in comparison with the

mode of entry in Item (b). Induction occurs when a lightning strike to ground gives

rise to electromagnetic and electrostatic fields. These fields induce an impulse in

conductors that intercept them. The conductors that are most affected are electricity

reticulation and telecommunications lines. Commonly, the former are not damaged

but the impulse may be transmitted to customer terminals and appear as a lower level

lightning-induced impulse. This may damage or disable some forms of

telecommunications equipment.

(d) Direct induction into internal building wiring This mechanism is similar to Item (c),

but the induction occurs directly into the building wiring itself. For this to be

significant, the lightning strike needs to be very near by, typically to the LPS itself.

Measures to reduce this effect, including reduction of installed conductor loop areas,

are discussed in Clause 5.6.4.

Protection systems designed to counteract EPR and other impulses will normally provide

adequate protection against impulses arising from the entry modes described in Items (b),

(c) and (d).

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 70: ASNZS 1768-2007

AS/NZS 1768:2007 68

COPYRIGHT

FIGURE 5.1 MODES OF ENTRY OF LIGHTNING IMPULSES

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 71: ASNZS 1768-2007

69 AS/NZS 1768:2007

COPYRIGHT

5.4 GENERAL CONSIDERATIONS FOR PROTECTION

Because of the many variables involved, each building will require specific consideration of

the protective measures that should be applied. Particular attention should be given to

possible entry and exit points for lightning current, which may include one or more of the

following:

(a) Rooftop or external structures (e.g. TV antennas, communications hardware such as

microwave dishes, metallic flues and ventilation outlets) or other exposed metal work

not protected by the LPS for the building structure (e.g. metallic guttering and

downpipes, metallic fences) These features will invariably be possible entry points for a

lightning discharge.

(b) The electricity supply service entry This will normally be an entry point for lightning if

the service is aerial or overhead. It may be either an entry point or an exit point if the service

is underground but it is more likely to be an exit point in such cases.

(c) The telecommunications services entry This may be an entry point if the service is

overhead using a dropwire or aerial cable. The service is more commonly underground and in

such cases could be either an entry point or exit point.

(d) Gas supply systems These are usually exit points for lightning but may occasionally

present an EPR entry condition.

(e) Metallic water supply and sewerage systems These are usually exit points for lightning

but may occasionally present an EPR entry condition.

(f) Other conductive services These are usually exit points for lightning but may

occasionally present an EPR entry condition.

(g) Building earthing systems (often there are several) These are usually exit points for

lightning but may occasionally present an EPR entry condition.

(h) The LPS for the building (if provided) By design these systems provide both an entry

and exit point for a lightning discharge but, because of bonding, will present an EPR

condition to other services.

An illustration of the possible entry and exit points for a lightning discharge is provided in

Figure 5.2.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 72: ASNZS 1768-2007

AS/NZS 1768:2007 70

COPYRIGHT

FIGURE 5.2 POSSIBLE ENTRY AND EXIT POINTS FOR A LIGHTNING DISCHARGE

5.5 PROTECTION OF PERSONS WITHIN BUILDINGS

5.5.1 Objectives of protection

The principal objective of measures for the protection of persons within buildings is to

prevent hazardous potential differences between conductive parts with which the person(s)

may be in contact. This is normally achieved by applying equipotential bonding between

any conductive path into and out of the building, i.e. the entry points and exit points

referred to in Clause 5.4.

If such bonding has been installed it does not matter if a person is subject to an EPR with

respect to distant earth as all conductive materials in the vicinity will be at approximately

the same potential.

An important consideration in the installation of equipotential bonding is how to install

such bonding without adversely affecting the operation of the various services involved,

particularly the protection systems associated with the respective systems. This is explained

further in Clause 5.5.2.

AS 4262.1 provides further information on the protection of users of telecommunications

equipment from overvoltages that may exist between a user environment and

telecommunications facilities in that environment.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 73: ASNZS 1768-2007

71 AS/NZS 1768:2007

COPYRIGHT

5.5.2 Installation of equipotential bonding

In general, if made of copper, bonding conductors shall have a cross-sectional area as given

below, unless they are main current-carrying conductors of the LPS. The typical dimensions

of the main current-carrying conductors of a LPS are given in Table 4.6.

All possible entry and exit points for the lightning discharge should be electrically bonded

together in as direct a manner as practicable. The route taken by the bonding conductors is

important. If incorrectly routed the bonding conductors themselves may damage other

circuits or equipment by induction or side-flashing as currents of the order of tens of

kiloamperes and voltages of the order of several thousand volts with respect to remote earth

may be involved. Consequently, bonding conductors should not be grouped with other

cables that are sensitive to induction unless the other cables are also bonded to the LPS. If

the bonding conductor is long (some tens of metres) it shall be considered as an impulse

transmission line, in which mode the protection afforded by the bonding will be limited.

Some specific recommendations applicable to bonding of the entry and exit points referred

to in Clause 5.4 are given below:

NOTE: Appendix E provides additional information on earthing and bonding.

(a) Rooftop antennae and communications hardware The bonding conductor should be

attached to the most substantial part of the structural metal supporting the equipment

consistent with it fulfilling the requirements of an air terminal for the LPS of a

building. The bonding conductor to the antenna or communications hardware should

be insulated to at least the level required in AS/NZS 3191, if run within the building,

but may be uninsulated if run externally. The cross-sectional area of the bonding

conductor should be not less than 16 mm2 if made of copper.

(b) The electricity supply service entry There are two distinct considerations that apply.

Firstly, the electrical installation earth should be bonded to the LPS earth termination

network with a copper conductor of not less than 6 mm2 cross-sectional area.

Secondly, SPDs should be installed for each active conductor of the electricity supply

service. Where an SPD is mounted on, or in, the building, its earthing system should

be bonded to the LPS by a conductor having a cross-sectional area of not less than

that utilized for its own earthing conductor. Where SPD equipment is separated from

the building (e.g. mounted on a customer’s electricity supply service pole), the SPD

earth should not be used as the earthing termination for the building LPS, however,

the LPS earth termination network and the SPD earth may be bonded together, if

desired.

(c) The telecommunications service entry This may be either aerial (overhead) or

underground. If aerial, the service should be regarded as a potential entry point for

lightning and an SPD should be fitted, subject to the requirements of the

telecommunications regulatory authority*. The telecommunications service earthing

system shall be bonded to the LPS earth termination network.

If the telecommunications service is underground, the service will act essentially as

an exit point for lightning. In this mode it may be necessary to fit an SPD to the

service to provide a bonding point for potential equalization.

The bonding conductor should have a cross-sectional area of not less than 6 mm2 if

made of copper.

* In Australia, these requirements are set out in AS/ACIF S009, Installation requirements for customer

cabling.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 74: ASNZS 1768-2007

AS/NZS 1768:2007 72

COPYRIGHT

(d) Metallic water supply and sewerage systems Metallic water supply and drainage

systems should be bonded to the LPS and connected to the electricity supply service

earth. However, some water supply authorities fit insulating spacers or ferrules for

galvanic corrosion control at customers’ installations. These may require bridging by

an SPD as determined in consultation with the water supply authority. Bonding

conductors to these services should have a cross-sectional area of not less than 4 mm2

if made of copper. Metallic piping systems associated with fire sprinklers, water, hot

water or flammable liquid, that are unavoidably in contact with the exposed

conductive parts of wiring enclosures, cable components or other electrical equipment

shall be connected to such equipment by means of an equipotential bonding

conductor.

If calculation or local experience indicates that the water supply system is of very low

resistance to earth (e.g. less than 0.5 Ω), it may well be the principal exit point for the

lightning impulse. In such circumstances, consideration should be given to upgrading

the current-carrying capacity of the bonding conductor between the LPS earth and the

water supply system to a cross-sectional area of not less than 35 mm2 if made of

copper.

(e) Other service lines Specific considerations may apply for some structures. For

example, a radio telephone tower should be bonded to its associated equipment

building; similarly, a pump station should be bonded to an elevated water tower. For

both examples given, the bonding conductor is likely to carry the full lightning

current and should therefore have a cross-sectional area of not less than 35 mm2 if

made of copper.

(f) Building earthing systems Buildings frequently have several earthing systems that

may be installed independently at different times. These include the electricity supply

service earthing system, the telecommunications earthing system (sometimes more

than one), the LPS earth termination network and other special purpose earthing

systems.

It is generally desirable to bond all such earthing systems but there may be specific

reasons for not doing so. Direct-current-carrying earths, e.g. older telex systems,

should usually be isolated to prevent corrosion damage to other services and earths.

In such cases consideration should be given to bonding these earths through a

galvanic isolator, to facilitate the protection of persons from lightning surges. This

type of isolator can be used where there is a corrosion-based objection to bonding,

e.g. copper-based earths to galvanized iron earths or structures, of which the latter

would suffer galvanic corrosion. If 50 Hz or audio frequency bonding is not needed, a

gas discharge arrestor may serve the purpose. Bonding conductors between earthing

systems should have a cross-sectional area of not less than 4 mm2 if made of copper.

(g) The LPS earth termination network Where an LPS is in place all of the services

described in Items (a) to (f) should be bonded to the LPS earth termination network.

Caution should be applied when bonding the LPS earth termination network to

cathodically-protected earthing systems, such as cathodically-protected concrete

reinforcing of fuel tanks. Bonding to such systems will require galvanic isolation as

in (f) above.

(h) Bonding of conductive parts Where a reinforced concrete pad, reinforced concrete

walls or metallic building components, e.g. a metal roof, are used as part of an LPS,

these should be interconnected with each other and bonded to the LPS. This bonding

should be performed regardless of whether the building is in a high risk lightning

area.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 75: ASNZS 1768-2007

73 AS/NZS 1768:2007

COPYRIGHT

5.6 PROTECTION OF EQUIPMENT

5.6.1 General

Lightning induces overvoltages in electrical service lines, including electricity supply,

telecommunications service lines, signalling, data, and coaxial lines. Cables carrying these

services usually have different points of entry to a structure and may have protective

devices connected to different earthing systems.

Equipment overvoltages may be experienced in the following ways:

(a) By direct conduction of lightning current on the conductors feeding into the building.

An example would be lightning striking overhead power lines. This mechanism is of

lower probability, but involves higher surge currents.

(b) Indirectly, (through magnetic induction, or electrostatic coupling) where lightning

strikes nearby, and surges are induced on the conductors feeding into the building.

This mechanism has a higher probability, but typically results in lower surge currents.

(c) Lightning striking the LPS or other nearby objects, resulting in an EPR. This can

cause potential differences in earthing systems, causing flashover and equipment

damage.

(d) Temporary overvoltages at mains a.c. system frequency that can occur for a number

of reasons.

The strategies to deal with this problem involve equipotential bonding of the earthing

systems, the provision of SPDs, and consideration of wiring practices and shielding

techniques, as appropriate.

AS 4262.2 provides further information on the protection of telecommunications equipment

from overvoltages.

5.6.2 Equipotential bonding for equipment protection

Equipotential bonding is dealt with in other sections of this Standard (Clause 5.5.2 and

Appendix E). The important aspect to note is that for effective protection of equipment,

very good attention needs to be paid to the implementation of the equipotential bonding

scheme. Voltage differences that are insufficient to cause injury to persons can be

extremely damaging to equipment. It is possible to have voltage drops in bonding

conductors that are carrying lightning surges in excess of 1000 V per metre.

It is important that bonding conductors be kept short to reduce this voltage difference, and

to achieve this, all services should enter in close proximity. For protection of equipment,

this concept can be extended to particular areas within the building. For example, consider

the case of a multistorey building with incoming underground services, and a telephone

system installed on an upper floor. On the lower level, the required equipotential bonding

will be performed, and primary surge protection to both power and telecommunications

lines can be fitted at that location, and will connect to the same equipotential earth system.

On this lower level, it may well be that the bonding conductor lengths are not ideal,

depending on where the services enter, and thus the protection provided is compromised.

However, on the upper floor where the telephone system is installed, the same concept can

be repeated, but at this point more control is possible over wiring and equipment locations.

That is, at this location all the services should enter the room at the same point, and

secondary surge protection to both power and telecommunications lines can be provided at

this location with short, direct connections to the common earthing point.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 76: ASNZS 1768-2007

AS/NZS 1768:2007 74

COPYRIGHT

5.6.3 Surge protective devices (SPDs)

5.6.3.1 Introduction to SPDs

An SPD is a device intended to mitigate surge overvoltages and overcurrents. To perform

this function, it generally has at least one non-linear component. That is, it behaves in a

relatively benign state until a voltage or current exceeds a predetermined value, then the

SPD begins to act to reduce the voltage or current, in order to prevent damage to equipment

being protected.

Although single components can be used as SPDs, often greater functionality is achieved by

combining components in various arrangements, and SPDs often have other features, such

as mechanisms to indicate their operational status.

5.6.3.2 Components

Overvoltage protective components usually fall into one of the following categories:

(a) Gas discharge devices These devices usually consist of glass or ceramic tubes filled

with an inert gas sealed at each end with a metal electrode. They have breakdown

voltages in the range 70 V to 1 kV with surge current ratings up to 100 kA. The strike

time and firing voltage of these devices are dependent on the rate of increase of

voltage. Unlike clamping devices, gas discharge devices conduct at a much lower

voltage than their firing voltage. This conduction voltage is typically below 30 V.

This fold-back behaviour generally precludes their use by themselves on a.c power

circuits.

Gas discharge devices are available in both two electrode and three electrode

configurations. The latter provide a means of clamping a pair of wires to earth if

either or both conductors are subjected to an overvoltage.

(b) Spark gaps These devices are similar in principle to a gas discharge device, but they

use air, rather than an inert gas, between the electrodes. The devices are inherently

rugged and can handle high surge energies, but typically suffer from relatively high

firing voltages. Devices are available that have been designed to operate on a.c.

power circuits, and their design incorporates mechanisms to extinguish the arc, and

prevent excessive follow-on current. Care needs to be exercised in their installation to

ensure that adequate clearances are provided, and that fusing is chosen that reduces

the incidence of nuisance fuse operation that may occur especially on low current

circuits. The manufacturer’s advice should be followed on these matters.

(c) Varistors Most modern varistors are made from metal oxide and are known as metal

oxide varistors (MOVs). The resistance of varistors drops significantly when the

voltage exceeds a limit thus clamping the voltage near the limit. The MOV is widely

used in SPD construction and offers a good balance between surge rating and

clamping voltage. Varistors are used on circuits operating at voltages between 10 V

and in excess of 1 kV. They can handle surges in the range of 3 to 100 kA and

respond in tens of nanoseconds. Because MOVs deteriorate with repeated operation,

it is usual to allow a high safety margin in the selection of the device rating in

lightning prone areas. Alternatively, facilities should be provided to give an

indication of device failure.

(d) Solid state devices One form consists of special zener diodes that exhibit voltage-

limiting characteristics and are optimized to handle surge currents. The breakdown

voltages of such devices are typically in the range 5 V to 200 V. They have current

ratings up to several hundred amperes and response times of the order of

10 picoseconds. Another form consists of thyristors, that switch when their operation

voltage is exceeded, and act to clamp overvoltages. Their reduced voltage during

conduction means they can handle higher surge currents, compared with the zener

diode type. Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 77: ASNZS 1768-2007

75 AS/NZS 1768:2007

COPYRIGHT

The main overvoltage protective components discussed in Items (a) to (d) belong to two

categories:

(i) Voltage-limiting components Sometimes referred to as clamping components, these

include varistors, avalanche or suppressor diodes.

(ii) Voltage-switching components Sometimes referred to as crowbar components, these

include air gaps, gas discharge tubes, thyristors (silicon-controlled rectifiers), triacs.

Care needs to be exercised when using voltage-switching components to make sure that the

devices will cease conduction once the surge has dissipated. The benefit of a voltage-

switching type component is their ability to handle relatively high surge currents.

Overcurrent protective components act to limit excessive currents. These are often used in

telecommunications and signalling circuits, and include fuses, and solid state components

providing the fusing function, but in a resettable manner.

5.6.3.3 SPD configuration

SPDs are configured as being either shunt or series protectors, defined as follows:

(a) Shunt protector Sometimes known as a one-port SPD, it is an SPD connected in

shunt with the circuit to be protected, as shown in Figure 5.3(a). A one-port device

may have separate input and output terminals without a specific series impedance

between these terminals, as shown in Figure 5.3(b). This latter arrangement is

sometimes known as a ‘series connected, shunt protector’.

A shunt protector with just two terminals (i.e. does not have separate input and output

terminals) has no inherent limitation with regard to the load current of the circuit to

which it is applied. However, its ability to clamp overvoltages is reduced by the

additional voltage drop that occurs across its connecting leads. For this reason, some

shunt protectors are manufactured with separate input and output terminals. This

arrangement substantially reduces the connecting lead voltage drop problem, but does

mean that the full load current passes through the device, which needs to be designed

to handle this current.

FIGURE 5.3 EXAMPLES OF SHUNT (ONE-PORT) PROTECTORS

(b) Series protector Sometimes known as a two-port SPD, it is an SPD with two sets of

terminals, input and output. A specific series impedance is inserted between these

terminals. Typical examples are shown in Figure 5.4.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 78: ASNZS 1768-2007

AS/NZS 1768:2007 76

COPYRIGHT

A series protector also has virtually no connecting lead voltage drop problem, and the

inclusion of the series component does allow coordination between different

overvoltage components, and also enables the creation of a true low pass filter

(generally by the addition of shunt capacitance after the series impedance) that allows

further surge attenuation. The series current limitation of the series protector will

typically be determined by the series impedance. Sometimes a protector is referred to

as an n-stage protector, and although this term is not consistently applied, the ‘n’

should refer to the number of shunt overvoltage stages that are separated by series

elements.

FIGURE 5.4 EXAMPLES OF SERIES (TWO-PORT) PROTECTORS

5.6.3.4 Multi-service surge protection device (MSPD)

An MSPD is a combination protector that combines both power protection and

signalling/telecommunications protection in the one device. It is an effective way of

protecting IT and associated equipment that has more than one connected service. By

including all the protection in the one device, the distance between the SPD earth

connections is very short, which dramatically reduces the potential difference between these

services under incident surge conditions. A general diagram of an MSPD is shown in

Figure 5.5.

FIGURE 5.5 MSPD CONFIGURATION

An example of an MSPD, and its installation, is given in Clause 5.6.5.3, Item (d).

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 79: ASNZS 1768-2007

77 AS/NZS 1768:2007

COPYRIGHT

5.6.3.5 Parameters of an SPD

There are many parameters that could be specified and measured or tested for an SPD, but

the primary parameters relate to how well an SPD limits overvoltages, how much surge

current it handles, and what voltage system is it designed for. The following parameters are

listed together with the IEC symbols for these parameters. It is suggested that

manufacturers and users adopt these parameters and symbols.

NOTES:

1 A product marked using these IEC symbols does not mean that it has been tested to the

relevant IEC Standards.

2 See Appendix F for definitions of the waveshapes.

Maximum continuous operating voltage (Uc)—This is the maximum voltage that can be

continuously applied to the protector. For the Australian and New Zealand power system,

this should be at least 275 V for SPDs connected between the phase and neutral conductors.

Rated load current (IL)—Maximum continuous rated r.m.s. or d.c. current that can be

supplied to a load connected to the protected output of an SPD.

Maximum surge current (Imax)—This is the peak value of the 8/20 μs waveshape current

impulse that the protector can handle. The protector only has to be able to withstand this

surge current once, and so this is known as the single shot rating.

Nominal surge current (In)—This is the peak value of the 8/20 μs waveshape current

impulse that the protector can handle many times. A protector must be able to withstand at

least 15 impulses at In.

Voltage protection level (Up)—This is the peak voltage that the protector protects to (limits

the voltage to). It is sometimes referred to as the let-through, or residual, voltage. Under

IEC 61643-1, it is measured at the value of In. However, there are practical issues with

gaining consistent voltage measurements at such high currents, and so it is recommended

that manufacturers quote the value of Up for a.c. power systems protectors at least for the

value of surge current equal to 3 kA, so that comparisons between protectors can be made.

In any case, the value stated for Up must be clearly coupled with the value of surge current

for which it applies.

NOTE: Where the SPD protects multiple modes (e.g. A-N, A-E and N-E) the surge ratings above

apply to each mode.

There are many other parameters that could be listed, for example, signalling protectors are

often tested with a 10/700 μs voltage waveshape, and have parameters such as insertion

loss, return loss, longitudinal balance, bit error rate, near-end crosstalk, etc, but such detail

is beyond the scope of this Standard.

The performance specification for a.c power systems SPDs incorporating filters is not well

specified in other Standards. The primary advantages of incorporating filters into SPD

designs is that they reduce the maximum dv/dt that occurs on the output of the filter, and

this can reduce equipment damage and upset. A suggested performance measure for filters

is—

SPD filter dv/dt—The average dv/dt occurring on the output of an SPD measured between

the 20% and 80% of the maximum voltage output, when the SPD is tested with a 6 kV

1.2/50 μs, 3 kA 8/20 μs waveform as shown in Figure F1. The filter should be loaded with a

resistive load representing 50% of the full load current.

Some SPDs include shunt capacitance that provides a filtering effect at EMI/RFI

frequencies, but provides little benefit at typical lightning surge frequencies. Similarly,

surge current levels may cause inductor saturation in standard EMI/RFI filters, which will

degrade the filter action.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 80: ASNZS 1768-2007

AS/NZS 1768:2007 78

COPYRIGHT

The use of an effective filter also typically reduces the let-through voltage of the SPD as

well, and this effect is captured by the Up parameter defined above.

5.6.3.6 Temporary overvoltage (TOV)

A TOV is the situation whereby the power frequency voltage on an a.c power system rises

above its normal value. This can be caused by many factors including poor regulation,

faults on the LV or HV distribution system (including phase shorts to neutral or earth, and

loss of neutral conductor), capacitor switching, sudden load rejection, and HV contact on

LV circuits. These events typically last from 0.2 s up to 5 s. The voltages that can occur

during these events are worse for TT and IT power systems, but even on the TN-C-S system

(the MEN system as used in Australia and New Zealand) may be up to 1.7 times the

nominal system voltage.

The effect of these TOVs on SPDs can be catastrophic. Manufacturers of SPDs should

consider this aspect in their product design, and ensure that if the product fails under these

conditions, that it does so safely, which generally means failing in a manner that cannot

cause a fire. The Standards IEC 61643-1 and UL 1449 have specific TOV tests to verify

safe failure mechanisms.

5.6.3.7 Application of SPDs

The following aspects should be considered in the application of SPDs:

(a) Modes of protection With any signal or electrical transmission system employing

two lines and a separate protection earth, two types of transients can occur. The first

type appears as a difference between the two lines, independent of their potential

differences to earth; this is known as a differential mode transient (also called

transverse mode or normal mode). It is illustrated in Figure 5.6 where the transient

voltage source is superimposed onto the normal signal carried by the lines.

The second type appears as a transient between each line and the earth, and is known

as a common mode transient (sometimes called a longitudinal transient). It is

illustrated in Figure 5.7 where the transient voltage sources are superimposed onto the

normal potentials between the lines and earth. This mode is that commonly

experienced by twisted pair circuits as each wire is equally exposed to the transient

voltage source.

FIGURE 5.6 DIFFERENTIAL MODE TRANSIENT

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 81: ASNZS 1768-2007

79 AS/NZS 1768:2007

COPYRIGHT

FIGURE 5.7 COMMON MODE TRANSIENT

The use of two non-earthed lines is common. The a.c. mains use the active and

neutral lines to supply electricity, with an accompanying earth line for protection.

Telephone lines use two wires over which the signal is transmitted, with neither line

tied to earth. RS-422 signalling for computer data uses two lines for each data

channel, which is known as balanced-pair signalling.

When protective equipment is connected to such lines, both differential and common

mode transients must be suppressed. Placing a protective device across the two

signalling lines alone is not sufficient. The high potentials to earth created by

common mode transients can cause insulation breakdown and arc-over, and can

damage electronic components. Protection against transients can be achieved by the

provision of voltage clamping or diversion devices between the lines, and between the

lines and earth. These will shunt common mode transients to earth before they are

allowed to reach breakdown potentials.

Equipment to be protected is typically more robust to transients from line to earth

(L–E) than for transients from line to line (L–L). This aspect can be capitalized on in

the design and application of SPDs. Telephone line and signalling line SPDs often use

a three terminal gas arrester as the primary energy handling component, and this

component provides both common mode and differential mode transients. Although a

gas arrester has a relatively high striking voltage, it typically provides sufficient

protection against the L–E transient, and if required, a varistor or solid state device

can provide additional L–L protection.

Similarly, experience has shown that a.c. equipment is more easily damaged from line

to neutral (L–N) transients, and although protection could be provided in all modes

(L–N, L–E, N–E), good protection is usually obtained by providing L–N and N–E

protection modes only. Indeed, at the building point-of-entry in a TN-C-S system, the

neutral conductor is connected to earth, and SPDs applied as recommended adjacent

to this MEN link, need only comprise of the L–N protection mode.

(b) SPD location There are many possible locations where SPDs could be installed

within a facility. The aim is to install SPDs in locations that provide effective

protection to the equipment nominated for protection, and to do so economically.

The most effective method of providing effective surge protection for a facility is to

provide SPDs at the building service point-of-entry (known as primary protection),

and then, if necessary, to provide additional surge protection within the building

closer to the equipment to be protected (known as secondary protection). Primary

protection is important because the main function of such an SPD is to keep most of

the surge current from entering the building, by diverting it directly to earth.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 82: ASNZS 1768-2007

AS/NZS 1768:2007 80

COPYRIGHT

When considering a.c. power circuit protection, the concept of location categories can

be used (see Figure F3). Location category C is the building point-of-entry and is

where primary protection would be installed. Location categories A and B are further

within the building and are potential locations for secondary protection, to be fitted as

required, especially in the following situations:

(i) Sensitive equipment is present. An example would be a computer room.

(ii) The distance between the SPD located at the entrance and the equipment to be

protected is too long (see Coordination in Item (d)).

(iii) There is internal equipment generating switching surges, or other internal

interference sources, inside the building.

(c) Surge ratings Having defined location categories, appropriate surge ratings for these

categories can be recommended. Before considering these ratings several aspects

need to be discussed—

(i) a lightning surge travelling within a building is attenuated by the SPDs it

encounters and the impedance from the building wiring itself. Thus higher

levels of surge current are likely to be encountered at the building point-of-

entry, compared to the distant end of a branch circuit;

(ii) in choosing an appropriate surge rating, it needs to be understood that the surge

rating of a SPD is a major factor in determining its useful lifetime. An SPD

with a particular Imax rating is not chosen on the basis of handling a single event

of that magnitude, but rather it will be expected to handle many events of a

lower amplitude;

NOTE: For example an SPD with an Imax rating of 40 kA might typically handle 15

surges of 15 kA.

(iii) the lightning surge current to be handled by a point-of-entry SPD has

traditionally been considered to come into the building via the service

conductors. However, another mechanism is now understood to exist. If

lightning strikes the building LPS, or even the ground or an object nearby, a

local EPR occurs. The incoming service conductors are typically referenced to a

distant earth (such as the neutral conductor grounded at the secondary

transformer some distance down the street, with the phase conductor also being

referenced to that distant earth by virtue of the transformer winding). The effect

of the local EPR is that a proportion of the lightning current flows out through

the point-of-entry SPDs on its way to reaching the distant earth. The surge

current in the SPDs in this case is very large, being a significant proportion of

the lightning current itself.

While Table 5.1 gives a surge rating for SPDs in this case (Category C3) using

the 8/20 μs waveshape, it should be acknowledged that the IEC standards make

reference to a 10/350 μs waveshape for use in this case, and the symbol given

to the current rating using this waveshape is Iimp. It has been found that a factor

of 10 may loosely be used to provide an indication of the equivalence between

these two waveshapes for typical SPD ratings. For example, an SPD

withstanding a 100 kA 8/20 μs impulse might be expected to withstand a 10 kA

10/350 μs impulse. The actual factor can only be determined for a particular

SPD by testing.

Given this discussion, for a.c. power system SPDs, the following surge current ratings

are recommended, where the surge rating is the Imax, or single shot, 8/20 μs value, and

apply for each SPD from the phase to neutral conductors.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 83: ASNZS 1768-2007

81 AS/NZS 1768:2007

COPYRIGHT

TABLE 5.1

RECOMMENDED SURGE RATINGS FOR A.C. POWER SYSTEM

SPDs PER PHASE

Category SPD location Imax

rating

A Long final subcircuits and electricity supply outlets 3 – 10 kA

B Major submains, short final subcircuits and load centres 10 – 40 kA

C1 Service entrance, other than below 40 kA

C2 Service entrance, building fed by long overhead service lines, or is

a large industrial or commercial premises

40 – 100 kA

C3 Service entrance, building in a high lightning area, or fitted with a

LPS

100 kA

(d) Coordination Often the approach taken is to have the primary SPD handle the bulk

energy (surge current) and not be too concerned about the Up value for that protector.

A secondary protector that will not need to handle such a high value of surge current,

can be installed close to the equipment and can be chosen to have an acceptable Up

value. However, to achieve this result, careful coordination between the two devices

needs to be undertaken. This is quite a complex matter, and a total examination of the

issues is beyond the scope of this Standard. However, a simple rule to apply is to

ensure that there is at least 10 to 20 m of electrical cabling between the two SPDs. If

this cannot be achieved, purpose built inductors are available that can be placed in the

circuit to achieve this effective separation.

A more complex primary SPD may incorporate multiple stages with the decoupling

impedance within the device itself, and such an approach ensures the stages are

properly coordinated and typically results in an SPD with good energy handling

capability and relatively low Up values.

(e) Fusing and wiring considerations It is essential to provide a fuse or circuit breaker

ahead of the SPD to provide for the safe disconnection of a failed SPD.

Manufacturers usually recommend an appropriate rating for such a fuse, and often the

value specified has been used in approval testing of the SPD. Safe disconnection of a

failed SPD would point toward a low amperage fuse, but too low a value will cause

nuisance operation as the SPD diverts surge currents. In the absence of any specific

guidance from the SPD manufacturer, a high rupturing capacity (HRC) 32 A or 63 A

fuse or circuit breaker with a fault rating compatible with the switchboard could be

used. SPDs should be installed after the main switch but prior to any residual current

device (RCD). The connection wiring from the main switch via the protective circuit

breaker and the SPD back to the neutral near the MEN point should be at least 6 mm2

and as short and direct as possible. This total connection lead length must be less than

1 m in length (ideally 300–600 mm). When carrying a lightning surge, the voltage

dropped across a conductor can be 1000 V/m, and is caused by the inductance, and

not the resistance, of the conductor. This is shown in Figure 5.8(a), and the voltage

drop across the connecting conductor adds to the Up of the protector. For example, if

the Up of the SPD was 600 V, and the interconnecting cable had a voltage drop of

1000 V, then the effective protection provided by the installed protector would be the

sum of these, at 1600 V.

If the terminals of the SPD are rated for the required load current level, a

configuration as shown in Figure 5.8(b) is preferred. This wiring method is

sometimes known as a Kelvin connection, and eliminates the interconnecting lead

problem. Failing this, twisting the connecting conductors together as shown in

Figure 5.8(c) can have a substantial impact on reducing the voltage drop.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 84: ASNZS 1768-2007

AS/NZS 1768:2007 82

COPYRIGHT

FIGURE 5.8 WIRING OF SPDs

(f) Failure modes of SPDs Typically an SPD initially fails to a low impedance state,

and the resulting a.c. current that then flows into the SPD either causes the SPDs

internal fusing to operate, or causes external fusing to operate. Consideration needs to

be given to the most desirable location for the external fuse, and whether it is

desirable for power to be disconnected from the load when the SPD fails. If the

external fuse is in series with the load current, power will be disconnected from the

load when the SPD fails. In some applications this is considered beneficial, since the

SPD is no longer protecting the load. However, locating the fuse in the non-load

carrying SPD connection wiring, means that a ruptured fuse will isolate the SPD, but

allow power to continue to the load.

SPDs are often fitted with some form of visual status indication to show their

operational status, and may additionally be fitted with contacts to allow for remote

monitoring.

(g) Withstand voltage of equipment The equipment to be protected may have a level of

resistability to surges designed into it. In particular, a resistance level to

electromagnetic interference (EMI) disturbances is mandated. Ideally, the Up of the

externally provided SPDs should be lower than the Up of any equipment internal

surge protection components, otherwise the internal components may be damaged

instead of being protected by the external SPDs. At some point in the future,

equipment to be protected may be marked with a surge voltage level that it will

withstand, and a symbol of Uw has been proposed for this withstand voltage.

Selection of SPDs to protect such equipment would be straightforward.

Lightning surges need not physically damage equipment for it to experience

problems. Erratic operation, that may or may not require manual resetting, can occur

and lead to data loss at surge levels which are lower than those required to cause

hardware failure. Rapid changes in the voltage supply, even those for which the

amplitude does not exceed the normal a.c. power peak, can cause problems. This

dv/dt problem can be reduced by utilizing SPDs with filters.

Figure F2 contains a curve that illustrates the typical voltage/time tolerance of

computing equipment.

5.6.4 Magnetic shielding and line routing

Magnetic shielding reduces incident electromagnetic fields, and can also provide a

reduction in the emissions from electrically noisy equipment being operated within the

building. The complexity of shielding can range from the use of metallic conduits, to simple

metal enclosures or cabinets, and up to whole rooms being comprised of shielding

materials. Such shields need to be earthed to be effective, and any SPDs provided to

conductors entering the shielded area need to be effectively connected to the shield.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 85: ASNZS 1768-2007

83 AS/NZS 1768:2007

COPYRIGHT

The amount of surge energy directly induced into building conductors from nearby

lightning strikes depends on the closeness of the current source, and the loop area formed

by the conductors. Conductors of the same service should be run together, along with an

earthing conductor, or otherwise run in close proximity to other earthed components, such

as earthed cable trays. To reduce the inductive loop area, such cables should be neatly tied

together and not allowed to splay out over the whole tray width, for example.

5.6.5 Practical installation examples

5.6.5.1 Determine protection needs

There are many aspects to providing effective lightning protection to equipment as has been

detailed in preceding clauses. However, it is useful to consider some examples that show a

simple methodology for determining where SPDs are required, and how to correctly apply

them.

The method consists of firstly determining what it is that requires protection, and then

drawing an imaginary box around it. Each location where electrical lines cross the box is a

potential location for SPDs, and they should be provided where the particular electrical line

is long or otherwise prone to having surges on it. Then the earths of the SPDs are connected

together as well as to the earths of the equipment, and taken to earth. If the initial box is

very large and services physically enter the box at widely spaced distances, it may be

prudent to draw other boxes inside (or alongside) the first, around particular items of

sensitive equipment to be protected, and repeat the process.

Typically it will be necessary to consider the following points for SPDs:

(a) At the point-of-entry of external services e.g. electricity supply and

telecommunications.

(b) At the connection of the external services to the equipment.

(c) At the connection of long internal cabling to the equipment e.g. communications and

LAN.

The following two mechanisms can damage equipment:

(i) An excessive voltage/current enters the building via a service due to either a lack of

protection or incorrectly installed protection.

NOTE: When protection is correctly installed both the mains and telecommunications point-

of-entry SPDs are bonded to the main earth bar by conductors of 1.5 m or less.

(ii) An excessive voltage/current is induced into the internal wiring loop.

5.6.5.2 Protection procedure

The procedure for protecting equipment is as follows:

(a) Install secondary protection at the equipment when the risk of damage due to

induction into the external service conductors (electricity supply and

telecommunications) and the building conductors exceeds an acceptable level.

(b) Install point-of-entry protection when the risk of damage due to a direct strike to the

structure or the service conductors exceeds an acceptable level.

NOTES:

1 A prime role of the point-of-entry protection, apart from preventing dangerous discharges

and step and touch potentials, is to protect the secondary protection from damage.

2 Telecommunications SPDs on customer cabling should be installed in accordance with

AS/ACIF S009 (in Australia only). In Australia, a licensed cabler must do this

installation. The installation of SPDs in the main switchboard (MSB) and in electrical

distribution boards (DBs) should be in accordance with AS/NZS 3000 and AS 4070. A

licensed electrician must do this installation. Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 86: ASNZS 1768-2007

AS/NZS 1768:2007 84

COPYRIGHT

5.6.5.3 Protection examples

The following examples show these principles being implemented:

(a) A central PLC and remote sensor In this example it is determined that a particular

industrial process must be protected. It consists of a central controller (PLC), and

various sensors and controls. For simplicity, the example will show two sensors, one

at a considerable distance from the PLC, and another close to the PLC. The

arrangement is as shown in Figure 5.9.

LEGEND:

BB = Bonding bar

MDF = Main distribution frame

MEB = Main earth bar

MEB = Main earth bar

MSB = Main switchboard

PLC = Programmable logic controller

FIGURE 5.9 EXAMPLE OF CENTRAL PLC AND REMOTE SENSOR

The PLC has a operator console and a modem to allow remote communication, and

consequently has electrical and telephone services. The signal line is over 1 km in

length. The first box is drawn around the PLC and associated close by equipment.

Other close by sensors or controls would be included within this box. Three electrical

services are identified that cross this box – the a.c. power, the telephone line, and the

signal line to the remote sensor. Since all three are long or otherwise prone to having

surges on them, they need SPDs. Since the operator console is close to the PLC there

is no reasonable likelihood of surges impinging on that connection. Likewise, any

sensors or controls close to the PLC would not normally require protection.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 87: ASNZS 1768-2007

85 AS/NZS 1768:2007

COPYRIGHT

Having identified the SPDs required close to the PLC, their installation is important.

They should be installed close to the equipment they are to protect, and must have

their earths connected together, and connected to the PLC earth, and taken to earth. In

practice, this might be laid out as follows. The PLC and modem are mounted next to

each other on a rack. Immediately below them, the required SPDs are mounted in a

row, with an earthing busbar immediately below them, connected at each end to the

rack frame. Each SPD will have a short direct connection to the busbar not exceeding

100 mm, and the PLC will also have a direct connection to the busbar. In this manner,

excellent equipotential bonding will be achieved for this equipment and associated

SPDs.

The SPD on the signal line at the PLC end does not provide protection for the remote

sensor. Again, a box is drawn around the sensor. The only line here is the signal line,

and so an SPD is provided on it. This SPD is earthed with a direct short connection to

the sensor earth (and associated pipe or vessel), and taken to a local earth. There is no

point in trying to connect this very distant earth to the PLC earth via a bonding

conductor.

In addition to the secondary SPDs installed closed to the equipment, the prudent

provision of primary point-of-entry SPDs has also been shown. Depending on the

assessed exposure of the signal line, which would include such considerations as

whether it is run in metallic conduit or not, it may be prudent to include primary

point-of-entry protection on the PLC signal lines where they enter the building, in

addition to the secondary protection shown at the PLC.

(b) A video surveillance system This example is very similar to the case just described.

The central monitoring and recording equipment will have surge protection applied to

the long video camera feeds and to the a.c. power line. The video feeds that are

selected for protection will need all the associated signal lines protected, and this may

include the video feed, the power supply leads, and any pan and tilt control signals.

The earths of these SPDs will connect to each other and to the equipment earth. Video

cameras that are located nearby in the same building may not need surge protection

fitted. Those video cameras that are located a long distance from the central

monitoring and recording equipment will need the same type of protection fitted at

the remote end as was fitted at the central end. The earths of these SPDs must be

connected to the video camera earth, and then be taken to a local earth. Although all

earth connections should be as short as possible, it is particularly important to keep

the length of the SPD earths to video camera earth short.

(c) A multistorey building with PABX on upper floor In this example illustrated in

Figure 5.10 it has been determined that protection is required. This is a multistorey

building with services entering on ground floor, and PABX on an upper floor. A box

has been drawn around the PABX. Regardless of whether the point-of-entry location

of the telecoms and power services are co-located, there can be induction into the

internal wiring between the ground floor and the PABX. Therefore the electricity

supply, the exchange line and the outdoor extensions will require protection at the

PABX. The local handsets do not need protection (inside the inner box). To ensure

adequate protection of the PABX it may be necessary to have a DB and a telecoms

distributor (IDF) co-located with the PABX. SPDs are installed in the DB and the

IDF. In areas where direct strike protection is required SPDs need to be installed at

the point-of-entry (see AS 4262.1).

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 88: ASNZS 1768-2007

AS/NZS 1768:2007 86

COPYRIGHT

LEGEND:

BB = Bonding bar

DB = Distribution board

IDF = Intermediate distribution frame

MDF = Main distribution frame

MEB = Main earth bar

MSB = Main switchboard

PABX = Private automatic branch exchange

FIGURE 5.10 EXAMPLE OF MULTISTOREY BUILDING WITH PABX

(d) A domestic computer and ADSL modem In this example it has been determined that

protection is required. Figure 5.11 shows how this has been implemented. A box has

been drawn around the ADSL modem and all interconnected equipment. A box has

also been drawn around the fax machine. The simplest way to provide SPDs with

short bonding conductors to a common earth point is to use an MSPD so this has been

used, along with a power board to provide additional protected outlets. A Fax

machine at the same physical location has also been protected using a second MSPD.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 89: ASNZS 1768-2007

87 AS/NZS 1768:2007

COPYRIGHT

LEGEND:

ADSL = Asynchronous digital subscriber line

MEB = Main earth bar

MSPD = Multi-service surge protection device

SB = Switchboard

FIGURE 5.11 EXAMPLE OF DOMESTIC COMPUTER AND ADSL MODEM

Although shown in Figure 5.11, point-of-entry protection would normally only be installed

in areas where direct strikes are likely.

(e) A rooftop cellular base station

In this example a cellular base station is located on the roof of a multistorey building.

Figure 5.12 shows an effective means of providing lightning, earthing and surge

protection.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 90: ASNZS 1768-2007

AS/NZS 1768:2007 88

COPYRIGHT

LEGEND:

BB = Bonding bar

DB = Distribution board

MEB = Main earth bar

MSB = Main switchboard

FIGURE 5.12 EXAMPLE OF ROOFTOP CELLULAR BASE STATION

The tower, being all steel, is self protecting. It should be bonded to the building lightning

protection system. If there is no building LPS the tower and cabin should be earthed by a

minimum of two downconductors. Should lightning strike the tower or the building LPS the

potential of the tower and cabin will rise. Therefore the tower and cabin together must be

treated as a separate entity.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 91: ASNZS 1768-2007

89 AS/NZS 1768:2007

COPYRIGHT

The a.c. power supply is fed to the base station distribution board from a main switchboard

located in the basement of the building. An SPD, normally a surge diverter, would be

installed at the MSB. A second SPD, a surge filter, is installed on the a.c. power feed to the

rooftop distribution board. All other metallic services, for example antenna feeders should

be bonded and fitted with SPDs. All equipment should be referenced to a common earth

bonding bar in the cabin and this in turn bonded to the tower and building LPS. There will

be a connection to the main a.c. earth via the earth conductor in the power cable to the roof.

Good practice would dictate that all metallic services should enter the cabin on the same

side and the common earth to the tower and LPS should exit the same side.

It should be noted that in the event of a lightning strike to the tower, conducted currents

will flow through the power earth conductor, and care should be taken to segregate cables if

possible.

Also, this description only considers the equipment inside the box (i.e. inside the cabin).

Antennas installed on the tower that contain electronics may require additional protection

measures.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 92: ASNZS 1768-2007

AS/NZS 1768:2007 90

COPYRIGHT

S E C T I O N 6 P R O T E C T I O N O F

M I S C E L L A N E O U S S T R U C T U R E S A N D

P R O P E R T Y

6.1 SCOPE OF SECTION

This Section provides recommendations for the protection of a variety of structures and

property against lightning where such protection is deemed necessary (see Section 2). The

recommendations of Sections 4 and 5 should be observed except where otherwise indicated.

6.2 STRUCTURES WITH ANTENNAS

6.2.1 Indoor antenna system

Structures protected against lightning in accordance with the recommendations of this

Standard may be equipped with indoor radio and television receiving antennas without

further precautions, provided that the separation between the antenna system, including its

down leads or feeders, and the external LPS or any of its internal sections is in accordance

with the values in Clause 4.16.

6.2.2 Outdoor antennas on protected structures

Structures protected against lightning in accordance with the recommendations of this

Standard may be equipped with outdoor radio and television receiving antennas without

further precautions, provided that every part of the antenna system, including any

supporting metalwork, is within the zone of protection of the LPS (see Clause 4.4). Where

these conditions cannot be fulfilled, precautions should be taken to ensure that the lightning

current can be discharged to earth without damage to the structure or injury to its occupants

with an antenna system fitted—

(a) directly onto a protected structure. This can be accomplished by connecting the

antenna bracket structure to the LPS at the nearest point accessible below the antenna

installation; or

(b) on a metallic support structure that projects above the LPS. This can be accomplished

by connecting the antenna support structure to the LPS at the nearest point accessible

below the antenna installation.

NOTE: Consideration should be given to the fitting of SPDs in the conductors connected to the

antenna system.

6.2.3 Antennas on unprotected structures

Before installing an antenna on an unprotected structure, the need to provide an LPS should

be assessed as described in Section 2.

6.2.4 Earthing of radio systems

The earthing electrode of the LPS may also be used for the purpose of earthing a radio

system.

6.3 STRUCTURES NEAR TREES

When a tree is struck by lightning, a voltage drop develops along its branches, trunk and

roots. The side-flash clearances between the tree and adjacent structures are set by taking

100 kV/m as the flashover strength of unseasoned wet timber and 500 kV/m as the

breakdown strength of air. If the tree does not exceed the height of the structure its presence

can be disregarded. If the tree is taller than the structure, the following clearances between

the structure and the tree may be considered as safe:

(a) For normal structures; one-third of the height of the structure.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 93: ASNZS 1768-2007

91 AS/NZS 1768:2007

COPYRIGHT

(b) For structures with explosive or highly-flammable contents; the height of the

structure.

If the clearances cannot be met then the structure should be fitted with lightning protection

in such a manner that the side-flash always terminates on the protection system.

If the tree is fitted with an LPS, no further protection will be necessary for the structure

provided that the conditions for the zone of protection and separation are fulfilled.

6.4 PROTECTION OF TREES

The protection of trees against the effects of lightning needs to be considered only where

the preservation of the tree is desired for historical or other reasons. For such cases the

following recommendations are made:

(a) A main downconductor should be run from the topmost part of the main stem to the

earth termination and should be protected from mechanical damage near ground level.

(b) Large upper branches should be provided with branch conductors bonded to the main

conductor.

(c) In the fixing of the conductors, allowance should be made for swaying in the wind

and the natural growth of the tree.

(d) Test joints may be waived.

(e) The earth termination should consist of two rods driven into the ground on opposite

sides of, and close to, the trunk of the tree. A strip conductor should be buried to a

depth of 300 mm to encircle the roots of the tree at a minimum distance of 8 m radius

from the centre of the tree or at a distance equal to 1 m beyond the spread of the

foliage, whichever is the greater. This conductor should also be bonded to the rods by

two radial conductors. The earth terminations and resistance should comply with

Clause 4.15.

(f) Where two or more trees are so close together that their encircling earth conductors

would intersect, one conductor adequately connected to the earth rods should be

buried so as to surround the roots of all the trees.

NOTE: The recommended earth termination network is designed to protect the roots of the tree

and to reduce the potential gradient, in the event of a lightning discharge to the tree, to a safe

value within the area bounded by the outer buried strip conductor.

6.5 CHIMNEYS, METAL GUY-WIRES OR WIRE ROPES

6.5.1 General

Metal guy-wires or wire ropes attached to steel anchor rods set in earth or buried reinforced

concrete anchor blocks may be considered as sufficiently earthed. Other guy-wires or wire

ropes should be earthed e.g. where fixed above ground to structures.

For means of securing conductors to structures, see Clause 4.10.

Metal chimneys or flues need no protection against lightning other than that afforded by

their construction, except that they should be properly earthed. If the construction of the

foundation does not provide ample electrical connection with the earth, earth connections

should be provided similar to those recommended for chimneys made of materials other

than metal (see Clause 6.5.3).

6.5.2 Metal ladders and metal linings

Where chimneys have a metal ladder or lining they should be connected to the LPS at their

upper and lower ends.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 94: ASNZS 1768-2007

AS/NZS 1768:2007 92

COPYRIGHT

6.5.3 Chimneys

Chimneys consisting partly or wholly of reinforced concrete should comply with the

recommendations of Clauses 4.5, 4.10, 4.12 and 4.16, and, in addition, the reinforcing metal

should be electrically connected together and electrically connected to the downconductors

at the top and bottom of the concrete.

Chimneys, other than those of reinforced concrete or metal construction, shall be protected

in accordance with the requirements of Section 4, when required by the risk assessment of

Section 2.

NOTE: In existing chimneys, the reinforcement of which may be electrically continuous, it is

recommended that additional connections be made at points where the reinforcing rods are

accessible.

6.6 PROTECTION OF MINES

6.6.1 Factors influencing need for protection

In mining operations, electric shocks, possible premature detonation of explosives, and

ignition of flammable gases from the effects of lightning are recognized additional hazards.

Because these hazards are associated with the effects of lightning at or below the ground

surface, factors additional to the risk assessment approach of Section 2 influence the need

to provide lightning protection. These additional factors are associated with earth

resistivity, depth of the mining operation, presence of persons and the presence of

flammable gas or explosives. The degree of hazard is regarded as greater the shallower the

depth of the operation and the higher the resistivity of the earth involved.

Generally, these additional factors will indicate that lightning protection should be provided

or precautionary work procedures adopted.

6.6.2 Object of recommendations

The following recommendations for lightning protection for mining operations are aimed at

reducing the risk of electric shock and premature detonation of explosives. While the

recommendations will also reduce the risk of ignition of flammable gases from the effects

of lightning, flammable gas ignition is best prevented by ensuring that flammable

concentrations of gases do not occur.

The intent of the recommended LPS is to reduce the possibility of substantial voltages

appearing between conducting structures and between conducting structures and earth in

their immediate vicinity. Absolute protection against the effects of lightning cannot,

however, be guaranteed with the recommended protection system alone. Consequently,

recommendations are also given for operational procedures for the use of explosives when

lightning occurs close to the mine site.

In surface workings, the premature detonation of explosives, both directly and through

electric detonators, are considered possible, while in underground operations, the premature

detonation of explosives is considered possible only through electric detonators.

6.6.3 Underground workings

6.6.3.1 General

The following recommendations apply particularly to underground workings where electric

detonators are used as the means of initiating explosives.

6.6.3.2 Electric detonators

Detonators specially designed to reduce the risk of ignition by electrical discharge across

the fuse head should be used.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 95: ASNZS 1768-2007

93 AS/NZS 1768:2007

COPYRIGHT

6.6.3.3 Shot firing circuit

Requirements for circuit equipment and procedures to be adopted for firing explosives

electrically are set out in AS 2187.2 or NZS 4403. Additional to those requirements, where

fixed wiring is used as part of the firing circuit, the conductors should be enclosed in metal

screening, armouring or conduit. This metal screening, armouring or conduit should be

connected to the electrical system earthing and bonded to other metallic structures as

described in Clause 6.6.3.7.

6.6.3.4 Overhead electricity supply service lines

To minimize the magnitude of incoming lightning surges on overhead electricity supply

service lines, overhead earth wires should be provided on all overhead electricity supply

service lines within 1.5 km of the mine.

Additionally, SPDs should be installed at the termination of the overhead electricity supply

service line for protection of connected cables or equipment.

6.6.3.5 Surface structures

Lightning protection should be provided on all structures above underground openings,

such as winder head frames. With other structures and buildings, the need to protect or not

should be determined from Section 2. It must be remembered that a surface LPS will still

discharge current to underground workings.

Lightning protection of surface structures should be carried out in accordance with

Section 4 and, where these buildings have explosive or highly-flammable contents, the

additional recommendations of Section 7.

Where various conductive structures, such as metallic enclosures of air, water and

electricity services, or reinforcing steel in concrete foundations, are laid in or on the

ground, advantage should be taken of these to reduce the earthing resistance of the LPS by

interconnecting and bonding these structures together and to the LPS earth termination

network. Typical sizes of bonding conductors are given in Table 4.6.

6.6.3.6 Bonding of surface metalwork

All metal structures entering openings to underground workings of a mine should be bonded

together at the point-of-entry to the opening and connected to the LPS earth termination

network of structures above the opening. This includes any reinforcing steel in the shaft,

concrete lining, shaft steel work, guides and ladders, armouring and sheathing of electrical

cables, air, water and ventilating pipes, rails and bell rope attachments. Typical sizes of

bonding conductors are given in Table 4.6.

6.6.3.7 Bonding of underground metalwork

In addition to the bonding recommended in Clause 6.6.3.6, metal structures and services in

underground access shafts should also be bonded together at intervals of not more than

75 m. Rock-bolted support structures are deemed to provide an adequate earth for this

purpose.

Winding ropes, guide ropes and balance ropes cannot be bonded to other structures except

at fixing points and, possibly ineffectively, through conveyances. High voltages relative to

their surrounds could occur during lightning activity.

6.6.3.8 Further precautions

The degree of hazard in any mine, both from electric shock and initiation of electric

detonators, is related to the depth of the operations. This relationship is inadequately

defined at present.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 96: ASNZS 1768-2007

AS/NZS 1768:2007 94

COPYRIGHT

Shaft sinking and drifting are particular operations where lightning is a recognized hazard.

With these operations all work associated with electrical blasting should be suspended and

persons withdrawn to a safe distance when an electrical storm is approaching.

A conservative approach would require that the precautions applied to shaft sinking and

drifting be applied to all underground operations.

6.6.4 Surface workings

6.6.4.1 General

The following recommendations apply to surface mining operations where any type of

explosive is used in the mining operation.

6.6.4.2 Equipment

For many surface workings involving blasting operations, action need only be taken in the

immediate vicinity of the area where blasting takes place. This is because no

interconnection by metallic structures, such as air/water/electricity services, exists with

distant structures or earth. Where these services exist the recommendations for underground

working, of Clauses 6.6.3.3 to 6.6.3.5 apply and, where practicable, the bonding

recommendations of Clause 6.6.3.7 should also apply. Where electric detonators are used,

electric detonators of the type described in Clause 6.6.3.2 should be used.

6.6.4.3 On-site precautions

All work associated with blasting operations should be suspended and persons should be

withdrawn to a safe distance from explosives when an electric storm is approaching.

High equipment, such as drilling rigs, shovels and draglines, that may increase lightning

locality concentration, should be moved to a safe distance from the area where blasting is to

take place prior to explosives being brought to the site.

6.6.5 Lightning detector

Specially designed lightning detectors should be provided to warn of approaching electrical

storms so that the precautions set out in Clauses 6.6.3.8 and 6.6.4.3 may be taken.

6.7 PROTECTION OF BOATS

6.7.1 General

A boat should be considered to be at risk both because of its method of construction (except

for metal-hulled boats) and because it forms a marked protrusion above the surrounding

water surfaces. Overseas statistics show that in excess of 10 percent of fatalities occurring

on cruising sailing boats are due to lightning.

While the principles to be applied will not differ from those for land-based structures, the

methods employed will depend on the form of construction and the type of boat to be

protected.

NOTE: For further detail on the protection of boats against lightning refer to ISO 10134 and

Paragraph G2, Ref 7.

6.7.2 Elements of the protection system

6.7.2.1 Air terminal

A metal mast or the metal fitting on a timber mast will act as an adequate air terminal.

6.7.2.2 Downconductors

The mast, if metallic or if provided with a metal track, and stays will both act as

downconductors and each should be connected to an earth termination.

Stays as small as 3 mm diameter steel wire will serve as effective downconductors, but may

be damaged under severe lightning discharges.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 97: ASNZS 1768-2007

95 AS/NZS 1768:2007

COPYRIGHT

6.7.2.3 Earthing

Any metal surface that is normally submerged in the water will provide adequate earthing.

Propellers, metal rudder surfaces and metal keels may be used. The earth plate for the radio

transmitter may also be used, providing that it is constructed of solid material and not of the

porous type. A metal or a ferro-cement hull also constitutes an adequate earth.

6.7.2.4 Metallic objects

Metallic objects that are permanent parts of the boat and whose function would not

seriously be affected by earthing should be made part of the LPS by interconnection with it.

NOTE: The purpose of interconnecting the metal parts of a boat with a downconductor is to

prevent side-flashes to metal objects that could form part of an alternative path to earth or which

could bridge out a substantial length of the downconductor.

A general rule is, that if the non-conducting part of the alternative path through such object

is less than one-eighth of the length of downconductor bridged out, then that object should

be electrically interconnected with the downconductor.

6.7.2.5 Radio transceivers

A whip antenna consisting of a fine wire embedded in a glass fibre tube cannot be

considered a satisfactory lightning conductor and should be folded down during a lightning

storm.

All radio equipment or other navigational equipment with exposed transducers such as

radar, wind speed/direction indicators, and the like, should be fitted with effectively-earthed

spark gaps or SPDs. Alternatively, input cabling should be disconnected from the

equipment if there appears to be imminent danger of the boat being struck by lightning.

6.7.2.6 Corrosion

Care should be taken that the design of the LPS does not promote the occurrence of

electrolytic or galvanic corrosion. Bonding of dissimilar metals and interconnection of the

earth terminals of different pieces of electrical equipment should not be undertaken without

expert knowledge of the possible problems involved (see also Clause 4.7.2).

6.7.3 Installation recommendations

6.7.3.1 Protection of boats with masts

Sailing or power boats that have a mast or masts of sufficient height to give an adequate

zone of protection in accordance with Clause 4.4 may be protected by earthing the lower

ends of the standing rigging and the base of a metallic mast, or the lower end of a

continuous metal sail track on a timber mast.

Where the mast of a boat is stepped on deck, particular care should be taken to ensure that

the conductor from the base of the mast follows a direct route if it passes through the

accommodation section of the boat, otherwise a situation analogous to that shown in

Figure 4.8 may occur.

A typical small sailing boat with aluminium mast stepped on deck, glass fibre hull with the

metal ballast encapsulated in the glass fibre (or unballasted and with a non-metallic

centreboard) and with chainplates moulded into the hull provides something of a problem.

In such cases, it is suggested that some protection be sought when necessary by temporarily

connecting the mast and stays together at deck level by a length of chain or other flexible

conductor and allowing a short length of chain or the conductor to hang in the water at each

chainplate.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 98: ASNZS 1768-2007

AS/NZS 1768:2007 96

COPYRIGHT

6.7.3.2 Protection of boats without masts

Boats without masts do not constitute as high a risk as boats with masts. However, where

the size of the boat is such as to cause a marked protrusion above the surrounding water

surfaces, such boats should be fitted with air terminals that will give at least the protection

recommended in Section 4 for land-based structures.

6.7.4 Precautions for persons and maintenance suggestions

To the extent consistent with safe handling and navigation of the boat during a lightning

storm, persons should remain inside a closed boat and avoid contact with metallic items

such as gear levers or spotlight control handles. Persons should stay as far as practicable

from any parts of the standing rigging or other items forming part of a downconductor. No

person should be in the water or dangle arms or legs in the water.

If a boat has been struck by lightning, compasses and navigation instruments should be

checked for calibration. Protective coatings on steel hulls and glass fibre sheathing over

ballast keels should also be checked for damage. All standing and running rigging and

associated fittings should be checked in detail.

6.7.5 Bonding the lightning protection system to the vessel’s electrical wiring system

earth

The interworking and bonding of the LPS on a boat should recognize that the electrical

wiring system on a boat is commonly only a final subcircuit. As such, the wiring will be

very light, and neither the live conductors (whether or not energized) nor the earthing

arrangements, are capable of carrying lightning discharge current. Even with a larger

vessel, where the wiring is for a submain or a complete installation with a generator, this

will often still be the case, though larger wire sizes would be in use.

As a consequence, the LPS should be designed initially as a self-contained unit, even as far

as selecting and arranging the most appropriate below water level earthing electrode, in

accordance with Clause 6.7.2.3.

The wiring systems likely to be encountered (see AS/NZS 3004) are—

(a) a conventional AS/NZS 3000 arrangement with an inlet socket; or

(b) a conventional arrangement, but with the shore earth broken (for voltages less than

about 2 V) by a galvanic isolator. The galvanic isolator may be located either on

board, or on shore; or

(c) a system where the need for an onboard earthing system is removed by either an

onboard or a shore-mounted isolation transformer.

Items (b) and (c) above are to avoid galvanic or electrolytic corrosion of metallic skin

fittings below the water line from interaction with shore earthing. It should be noted that

Item (c) is not intended to give effect to the usual function of isolation transformers, which

is to avoid earth path electric shock. The ship installation may have common fed

accessories off the isolation transformer secondary, and all systems may incorporate RCD

protection. One side of the isolation transformer secondary may be a pseudo ‘neutral’ with

ship earthing.

In such cases, a ship earth or ship bonding of one side of the isolation transformer

secondary would be expected to be provided. Ships wired to earlier standards or overseas

standards may vary from the above.

When the LPS is completed, the earthing conductor at its final point connection to its

chosen earth termination network should be bonded to the ship earth or ship bonding point

at its termination. Where the bonding conductor on the electrical wiring is not actually

terminated on ‘earth’, the bond from the LPS should be connected to its lowest (height)

control point by a conductor of not less than twice the cross-sectional area of the electrical

wiring system.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 99: ASNZS 1768-2007

97 AS/NZS 1768:2007

COPYRIGHT

6.8 FENCES

If an extended length of metal fence is struck it is raised momentarily to a high potential

relative to earth. Persons or livestock in close proximity to, or in contact with, such fencing

at the time of a lightning discharge to the fencing may therefore be exposed to danger.

Fences that give rise to the most risk are those constructed with posts of poor conducting

material, such as wood or concrete. Fences built with metal posts set in earth are less

hazardous, especially if the electrical continuity is broken. Breaking the electrical

continuity prevents a lightning stroke from affecting the entire length of a fence, as it can if

the stroke is direct and the fence continuous, even though earthed.

Thus it is desirable to limit the length of fencing so affected by the provision of gaps, and

also to provide several earthing electrodes in each section so as to facilitate the discharge to

earth of the lightning current. In addition, persons or livestock can be endangered by

potential differences in the ground in the proximity of fences (see Figure 6.1). The risk is

greatest on rocky ground.

No value can be given for the earth termination resistance, since this must be largely

governed by the physical conditions encountered, but the lower the resistance to earth the

less risk will result to persons and livestock. In this connection, it should be borne in mind

that because of large body spans and bare contact areas many types of livestock are more

susceptible to electric shock than humans.

FIGURE 6.1 EQUIPOTENTIAL LINES NEAR METAL FENCE CAUSED

BY LIGHTNING DISCHARGE TO FENCE

6.9 MISCELLANEOUS STRUCTURES

6.9.1 Shelters, shade structures and rotundas in the public domain

Structures of this nature, which have metallic roofs supported on wood or other electrically

non-conductive materials, shall have the metallic roof earthed by a minimum of two

standard downconductors at intervals not exceeding 20 m of the roof perimeter. These

downconductors should be arranged outside the structure away from exits and entrances and

to reduce the hazard of touch potential, should be installed in a suitable heavy duty

electrical conduit to the AS/NZS 2053 series. Where the metallic roof is in contact with,

and supported by, metallic supports, no additional downconductors are required.

In the case of structures of this nature with a non-conductive roof, air terminations and

downconductors shall be installed as per Section 4, with earthing as described below.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 100: ASNZS 1768-2007

AS/NZS 1768:2007 98

COPYRIGHT

Each specially provided downconductor shall be suitably earthed. Where doubt exists as to

the effective earthing of metallic supports being used as downconductors, they should also

be suitably earthed.

In addition to these minimum requirements, further protection may be afforded to the

occupants of the shelter by installation of a ring earth.

6.9.2 Large tents and marquees

Where large temporary structures of this type are used for such purposes as exhibitions and

entertainments involving large numbers of people, consideration should be given to their

protection against lightning. In general such structures are manufactured from non-metallic

materials and the simplest form of protection will usually consist of one or more horizontal

air terminals suspended above them and connected solidly to earth. A non-metallic

extension of the vertical supports provided for such structures may, if convenient and

practicable, be used for supporting a network of horizontal air terminals but a clearance of

not less than 1.5 m should be maintained between the conductor and the fabric of the

enclosure. Downconductors should be arranged outside the structure away from exits and

entrances and be connected to earthing rods that, in turn, should be connected to a ring

conductor in such a manner as to be inaccessible to the general public. Those types of

tented structure that have metal frameworks should have these efficiently bonded to earth at

intervals of not more than 20 m of perimeter.

6.9.3 Small tents

For small tents, no specific recommendations can be given.

6.9.4 Metal scaffolding and similar structures, including overbridges

Where metal scaffolding is readily accessible to the general public, particularly when it is

erected over and on part of the common highway or may be used in the construction of

public seating accommodation, it should be efficiently bonded to earth. A simple method of

bonding such structures consists of running a strip of metal other than aluminium, 20 mm ×

3 mm size, underneath and in contact with the base plates carrying the vertical members of

the scaffolding and earthing it at intervals not exceeding 20 m. With public seating

accommodation only the peripheral members of the structure need bonding to earth. Other

steel structures, such as those used for pedestrian bridges over main trunk roads, are

frequently sited in isolated situations where they may be prone to lightning strikes and

should therefore be bonded to earth, particularly at the approach points.

6.9.5 Tall metal masts, towers, cranes and revolving and travelling structures

Masts and their guy-wires, floodlighting towers and other similar structures of metallic

construction, particularly those to which the general public have access, should be earthed

in accordance with this Standard.

Cranes and other tall lifting appliances used for building construction purposes, shipyards

and port installations should also be bonded to earth. For cranes or revolving structures

mounted on rails, efficient earthing of the rails, preferably at more than one point, will

usually provide adequate lightning protection.

In special cases, where concern is felt regarding possible damage by lightning to bearings,

additional measures may be justified.

Mobile towers, portable cranes and similar structures mounted on vehicles with pneumatic

tyres can be given a limited degree of protection against lightning damage by drag chains or

tyres of conducting rubber such as are provided for dissipating static electricity.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 101: ASNZS 1768-2007

99 AS/NZS 1768:2007

COPYRIGHT

6.10 PROTECTION OF HOUSES AND SMALL BUILDINGS

6.10.1 General considerations

The application of this Clause is intended to be restricted to relatively small buildings, such

as houses or similar buildings, of a smaller size than those envisaged in Section 4 of this

Standard.

Lightning protection for a house or small building in complete accordance with the

recommendations of Section 4 may be difficult to justify on economic grounds. However,

there may be a need to provide some degree of protection against lightning damage.

Houses and small buildings vary greatly in the degree to which their construction provides

inherent lightning protection. Small buildings with mainly non-metallic materials offer little

or no inherent protection against lightning, whereas a building with a metallic roof, metallic

gutters, and metallic downpipes leading into the ground has a high degree of inherent

protection, since the main elements of an LPS are already present.

If lightning strikes a house with little or no inherent lightning protection, the lightning is

likely to penetrate the roof and attach to electrical wiring in the roof area. This will usually

result in damage to electrical equipment in the house, and in some cases, may result in a

fire, or in hazard to persons within the house.

The objective in protecting small buildings should be to provide conductors to intercept the

lightning, to provide a low-resistance path to earth, and to provide at least two earth stakes

or equivalent earthing electrodes for conveying the lightning current into the earth.

6.10.2 Air terminal network for the building

If the building roof consists mainly of metallic materials, then it will serve as the air

terminal network. It is necessary to ensure that there is electrical continuity between the

various parts of the roof. Adequate continuity will often be provided by the way in which

the metallic parts are overlapped and fastened.

If the building roof consists mainly of non-metallic materials, then an air terminal network

should be provided. Suitable materials are listed in Clause 4.7. Copper wire and copper

strip are recommended for their durability. At least one conductor should be run along the

highest parts of the roof, for example, the highest ridge of the building. If the roof has a

complicated shape, it may be necessary to run additional conductors along the highest parts

of each section of the roof. All conductors should be joined together.

To be in accordance with this Standard, the cross-sectional area of the conductors should be

not less than 35 mm2, achieved, for example, by copper strip 25 mm × 1.5 mm. However, it

should be realized that much thinner conductors are able to carry most lightning currents

without damage. Even if the conductor were to melt, it would have carried out its function

for that one strike, as the lightning current would flow through the path of the molten metal,

rather than penetrate below the roof of the house.

For a large, more-or-less flat roof of non-conducting material, the simplest form of air

terminal network may be a series of vertical metallic rods above the roof level, all

connected together. The zone of protection provided by a vertical rod may be estimated

using the information in Clause 4.4.

Metallic gutters may become a strike attachment point. If there are metallic gutters around

the roof, these should be connected to the air terminal network. With metallic roofs, these

connections may already exist in the fastenings of the guttering to the roof. With

non-metallic roofs, the guttering should be connected to the air terminal network at no less

than two points.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 102: ASNZS 1768-2007

AS/NZS 1768:2007 100

COPYRIGHT

6.10.3 Provision of downconductors for the building

There should be at least two low-resistance paths to convey the current from any lightning

strike to the roof to earth. Metallic downpipes from metallic gutters may be used for this

purpose, provided that they afford a direct electrically continuous path for the lightning

current. In the absence of any low-resistance path from roof to earth, at least two

conductors should be provided to serve as downconductors. These may be continuations of

the conductors forming part of the air terminal network, and the same recommendations

apply as in Clause 6.10.2.

6.10.4 Provision of earthing electrodes

A path to earth for the lightning current should be provided at no less than two well

separated points, for example, at opposite ends of the house. Preference should be given to

areas that are usually damp, such as gardens. A metallic water pipe buried in the ground

would be a satisfactory earthing electrode provided that the water pipe is also connected to

the electricity supply service earth.

Each downconductor should be connected to an earthing electrode by the shortest possible

route, with the proviso that downconductors and earthing electrodes should not be placed

close to entry doors, or places where persons are likely to stay for long periods. For

example, earthing electrodes should not be placed close to swimming pools.

Earthing electrodes and their connected conductors should be examined periodically to

ensure that they are intact, and not suffering corrosion or mechanical damage.

6.11 PROTECTION OF METALLIC PIPELINES

Recommendations for the protection of metallic pipelines are given in AS/NZS 4853.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 103: ASNZS 1768-2007

101 AS/NZS 1768:2007

COPYRIGHT

S E C T I O N 7 P R O T E C T I O N O F

S T R U C T U R E S W I T H E X P L O S I V E O R

H I G H L Y - F L A M M A B L E C O N T E N T S

7.1 SCOPE OF SECTION

This Section provides a guide to the protection of structures containing explosives, or

highly-flammable solids, liquids, gases, vapours or dusts, from lightning or induced

discharges, and indicates ways of protecting those structures that are not inherently

self-protecting. Reference should be made to the AS/NZS 2430 series for information on

areas that are likely to have an explosive atmosphere. Reference should also be made to

AS/NZS 1020 for information on the control of static discharges.

7.2 GENERAL CONSIDERATIONS

7.2.1 Risk assessment

The approach for the assessment and management of risk due to lightning detailed in

Section 2 may be applied to structures with explosive or highly-flammable contents.

In some cases, the risk to life and property may be so obvious that the provision of every

means possible for protection from the consequences of a lightning discharge is essential.

Similarly, the owner of such a facility may decide that there should be no avoidable risk

and specify that every means possible for protection from the consequences of a lightning

discharge be installed.

Alternatively, the risk may be assessed as acceptable where the quantity of dangerous

material is strictly limited, as in a laboratory or small store, or where the structure is

specifically designed and situated to restrict the effects of a catastrophe. Also, lightning

protection may not be necessary in some circumstances where the dangerous materials are

not exposed but are completely encased in metal of an adequate thickness.

7.2.2 Protection required

Unless the risk assessment considerations in Clause 7.2.1 indicate that protection is not

required, the recommendations in this section should be followed for structures in which

explosives or highly-flammable solids, liquids, gases, vapours or dusts may accumulate, i.e.

in those areas that may be classified as hazardous.

Due to the increased risk, protection level I as defined in Section 4 should be applied to

these structures (e.g. a rolling sphere of 20 m radius when using the RSM).

7.2.3 Electrostatic shielding

The electrostatic induced voltage on isolated objects in the field of a storm cloud may cause

sparks to earth when a lightning discharge occurs to some adjacent object. Isolated objects

within a structure that is adequately shielded will themselves be electrostatically shielded.

If the structure is not shielded or is only partly shielded, then the isolated objects should be

earthed to prevent electrostatic sparks. For further discussion on the earthing of isolated

internal objects, see Section 5.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 104: ASNZS 1768-2007

AS/NZS 1768:2007 102

COPYRIGHT

7.3 AREAS OF APPLICATION

Protection should, in all cases, be provided for the following structures:

(a) Tanks and vessels containing flammable solids, liquids, vapours or gases, or

highly-flammable or explosive dusts.

(b) All metallic pipes and electricity supply and telecommunications service lines at the

point where they enter or leave a hazardous area.

Piping that is not in electrical contact with its associated tank or vessel, such as an

open discharge line into a water tank, should be bonded to the tank or vessel by a

flexible conductor, and earthed. Cathodic protection may justify the insertion of an

insulating flange that will interrupt the electrical continuity of the total length of line.

Cathodic protection usually has its converter and monitoring equipment outside the

hazardous area, with ELV d.c. leads feeding into the latter. This may require separate

protection to each part of the circuit.

Where flexible connections between pipelines and tanks do not incorporate an

earth-continuity conductor, a separate conductor for earthing should be provided. No

pipeline should be used for earth-continuity purposes as a substitute for the

recommended earthing conductor.

(c) Buildings that may contain explosive or large quantities of highly-flammable

materials, or nominated buildings that may, in an emergency, be used for the storage

of explosives.

(d) Buildings that may contain small quantities of highly-flammable material or a large

quantity of combustible material if sited within 50 m of a building specified in Item

(c).

(e) Any structure sited within 30 m of a building containing explosives, which thus

constitutes a projectile hazard to this building in the event of dislodgment of masonry

and the like by lightning.

(f) Any structure sited within 30 m of a building containing explosives that, if struck by

lightning, might constitute a subsequent fire hazard.

7.4 EQUIPMENT APPLICATION

7.4.1 Earth bonding points

Earth bonding points should be designed and installed to provide permanent, electrically

sound connections between the tank, plant or structure and the earthing system.

The bonding points can be bosses tapped to receive a bolt up to 50 mm long, a tag

(minimum 50 × 50 × 10 mm) or a 50 mm threaded stud. The points should be fabricated to

provide or accept a minimum of M10 (10 mm diameter) bolt, lug or fixing.

Earth bonding points should be fabricated from the same (or compatible) metal as the

structure it is being welded to. Pressure vessels should be provided by the manufacturer

with a suitable bonding point to take the earth connection.

In order to avoid corrosion, earth bonding points should be installed not less than 500 mm

above ground level. In addition, all earth connections to the points should be protected with

a suitable corrosion inhibiting compound or paint.

7.4.2 Bonding conductors

Where various items of process plant or a number of vessels are mounted on an extensive

concrete plinth that elevates the equipment above ground level, bonding conductors should

be provided to form a common earth connection for all the downconductors from the plant.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 105: ASNZS 1768-2007

103 AS/NZS 1768:2007

COPYRIGHT

Copper strip should be installed along two opposite sides of the plinth, fastened to the walls

not less than 500 mm above ground level to avoid corrosion. Tee-joints may be used

between down and bonding conductor. Diagonally opposite ends of the base conductor

should be provided with a test link from which connection is made to the earth termination

network, preferably to earth busbars that provide alternative earth connections.

Where one bonding conductor only is installed, test links and earth connections should be

provided at each end.

7.4.3 Sizes of copper strips

Sizes of copper strips should be in accordance with Table 4.6. For common earthing

systems, larger sizes may be needed depending on the fault current. These should be

selected in accordance with AS/NZS 3000.

7.4.4 Downconductors (see Clause 4.12)

All high salient structures within a process area should be provided with at least two

downconductors unless they are of welded construction or electrically continuous down to

base level.

Wherever possible, downconductors should be installed remote from stairs and operational

walkways and ladders.

Downconductors should preferably be installed at diagonally opposite corners of the

structure in positions that provide the shortest possible path for connection to the earth

termination network. They should be installed on the outside of the structure and should not

pass through it.

Copper strip should be used for downconductors and while, wherever possible, it should be

in a continuous length, test links may be attached for connection of down or base

conductors at various levels.

Where structural steelwork or columns do not require the installation of an air terminal, the

downconductor should extend from above the highest point of the structure.

Provision should be made for thermal expansion of the earthing conductor and associated

structure.

A test link should be installed in the downconductor in accordance with Clause 4.13, not

less than 500 mm above ground level.

Each downconductor from the highest point or points within the process area should take

the shortest possible path direct to earth and should be equipped with its own set of earthing

electrodes to provide a path of minimum impedance for a lightning discharge. The earthing

electrodes should be interconnected below ground level with the bonding conductor(s)

belonging to other earthing systems.

7.4.5 Air terminals (see Clause 4.11)

All high salient structures that are not electrically continuous and that are not within the

zone of protection of an adjacent protected structure should be equipped with air terminals

in accordance with the recommendations of this Standard.

Where two or more air terminals are employed they should be interconnected by roof

conductors for connection to at least two downconductors as follows:

(a) Roof conductors Copper strips should take the shortest salient route between the

various air terminals, with fasteners spaced as for downconductors.

(b) Air terminal network Buildings that are protected by an air terminal network should

be provided with at least two downconductors, that should be directly connected to

the most widely-spaced parts of the air terminal network. Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 106: ASNZS 1768-2007

AS/NZS 1768:2007 104

COPYRIGHT

7.5 SPECIFIC OCCUPANCIES

7.5.1 Protection of steel tanks

7.5.1.1 General precautions

The following precautions should be taken to minimize the effects of lightning discharge on

tanks containing petroleum products, including tanks with fixed roofs and tanks with

floating roofs:

(a) The shells of all tanks intended for the storage of highly-flammable liquids that can

produce an explosive gas atmosphere should be permanently and effectively earthed.

Other tanks, such as water tanks, if located in a hazardous area should also be

permanently and effectively earthed.

The combined earth resistance of permanent earth connections to the tank should not

exceed 10 Ω.

The recommended method of earthing is by means of earthing electrodes as detailed

in Clause 4.15, but in some installations soil conditions and the earth resistance of the

tank when isolated from associated pipelines may in themselves constitute permanent

and effective earthing. In such cases, the necessity for tank earthing electrodes should

be considered with particular reference to site measurements of earth resistance.

(b) The minimum number of individual earthing electrodes on storage tanks will depend

upon the diameter and soil condition, and should be in accordance with the following

schedule for single tanks:

Diameter of tank m

Minimum number of independent earthing

electrodes

≤ 30 2

> 30 3

For a group of small tanks, earthing electrodes common to the group may be installed,

provided that each tank has two independent paths to earth. One of these paths may

be through the pipeline earthing system.

NOTE: The reason for the minimum of two earthing electrodes is that during testing of one

electrode the tank will remain earthed by the other electrode.

Earthing electrodes for a tank may be interconnected around the periphery of the tank,

and where two or more connections are used they should be spaced symmetrically

round the tank.

(c) Each earthing conductor should be terminated and attached by means of a bolted

connection to a steel boss welded to the tank body. The steel boss should be tapped to

receive a bolt or stud, preferably 10 mm diameter. Lock washers should be used on

the connecting assembly. Soldered connections should be avoided. It is suggested that

the boss be welded on the tank at a minimum height of 500 mm above the bottom of

the tank.

(d) When a pipe or rod earthing electrode is driven into the ground, mechanical

protection should be given to the head of the electrode.

NOTE: It is the practice of some organizations to enclose all earth stake heads in a pit, where

they are associated with ‘special’ earthing, such as lightning protection or static earthing.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 107: ASNZS 1768-2007

105 AS/NZS 1768:2007

COPYRIGHT

(e) Steel tanks with floating roofs should be protected by one of the measures described

in Items (i) and (ii):

(i) Multiple parallel connections between the floating roof and the tank shell, in

particular those designs incorporating mechanical linkage in the seal assembly.

This is the most effective method of discharging induced static charges caused

by atmospheric conditions; under this arrangement it is not necessary to bond

across internal drainpipe joints or external moving stairway joints.

(ii) Overhead earth wires or other suitable forms of interception protection in

accordance with Clause 4.4 (see also Clause 7.2.2). This may be appropriate in

areas where there is a known high ground flash density.

7.5.1.2 Above-ground steel tanks containing flammable liquids at atmospheric pressure

The contents of steel tanks with steel roofs of riveted, bolted, or welded construction, with

or without supporting members, used for the storage of flammable liquids, are considered to

be reasonably well protected against lightning if the tanks comply with the following

recommendations:

(a) All joints between steel plates should be riveted, bolted, or welded.

(b) All pipes entering the tank should be metallically bonded to the tank at the point of

entrance.

(c) All vapour or gas openings should be closed.

(d) The metal tank and roof should have adequate thickness so that holes will not be

burned through by lightning discharges (5 mm sheet steel roofs on tanks are

considered adequate for this purpose*).

(e) The roof should be continuously welded to the shell, or bolted, or riveted and

caulked, to provide a gastight seam and electrical continuity.

7.5.1.3 Steel tanks with non-metallic roofs

Steel tanks with wooden or other non-metallic roofs are not considered to be

self-protecting, even if the roof is essentially gastight and sheathed with thin metal and with

all gas openings closed or flameproofed.

Such tanks should be provided with air terminals of sufficient height and number to receive

all discharges and keep them away from the roof. The air terminals should be thoroughly

bonded to each other, to the metallic sheathing, if any, and to the tank. Isolated metal parts

should be avoided, or else bonded to the tank. In lieu of air terminals any of the following

may be used:

(a) Conducting masts suitably spaced around the tank.

(b) Overhead earth wires.

(c) A combination of masts and overhead earth wires.

7.5.2 Installations handling crude oil and products—Jetties for marine tankers and

barges

The following recommendations should be observed as applicable:

(a) General All pipelines to jetties and any structural steelwork, plant and bollards on

jetties together with associated dolphins, walkways, and shore bollards should be

bonded to the electrical installation earthing system.

* This value is based on a recommendation in ANSI/NFPA 780.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 108: ASNZS 1768-2007

AS/NZS 1768:2007 106

COPYRIGHT

Electrical equipment on a jetty should be connected to an earthing system as specified

in AS/NZS 3004.

Dependent upon site and operating conditions, it may be possible to obtain overall

protection by using one earthing system. Where it is considered that one common

earthing system may be adapted to comply with all the requirements, it is necessary to

ensure that the value of earth resistance does not exceed 4 Ω.

Where steel or steel box piles are not employed, an earthing conductor should be

installed to enter the water below low water mark to provide a direct path for

lightning discharge.

(b) Jetties with cathodic protection It is recommended that the following precautions be

taken where jetties are protected by either sacrificial anodes or power-impressed

systems to prevent sparking at the tanker manifold when loading lines are being

connected or disconnected:

(i) Install an insulating flange at the jetty end of each loading line between jetty

and vessel whereby all flanges shore-side of the insulating flange are earthed to

the jetty earthing system and all flanges to the seaward side are earthed via the

vessel.

(ii) Ensure that the insulating flange cannot inadvertently be short-circuited by the

electrical connection of exposed metallic flanges on the seaward side of the

insulating flange to the jetty structure either by direct contact or by hose-

handling equipment.

(iii) Where sacrificial anodes are installed, it may be necessary to use manila

mooring ropes or straps to extend the life of the anodes and minimize current

flow between jetty and vessel.

(c) Ship/shore bonding cables An independent cable bonding connection between ship

and jetty, with or without cathodic protection, is not considered as serving any useful

purpose in—

(i) the dispersal of static electricity; or

(ii) minimizing possible current flow in conductive type loading hoses.

7.5.3 Aircraft fuelling and de-fuelling

Aircraft fuelling and de-fuelling should be suspended when electrical storms are in the

vicinity.

7.5.4 Structures with explosive or highly-flammable contents

7.5.4.1 Methods of protection

Structures with explosive or highly-flammable contents should be protected in one or more

of the ways detailed in Clauses 7.5.4.2 to 7.5.4.6 and in accordance with the

recommendations of Clauses 7.5.4.7 to 7.5.4.16, as appropriate.

7.5.4.2 Air terminal network

An air terminal network should be suspended at an adequate height above the area to be

protected (see Clause 4.4).

Where a suspended conductor crosses chimneys or vents that emit explosive dusts or gases

under forced draught, the suspended conductors should be not less than 5 m above the

chimney or vent.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 109: ASNZS 1768-2007

107 AS/NZS 1768:2007

COPYRIGHT

7.5.4.3 Network of horizontal conductors

Where the expense of the method described in Clause 7.5.4.2 cannot be justified, and where

no risk is involved in discharging the lightning current over the surface of the structure to

be protected, a network of horizontal conductors with a mesh between 3 m and 8 m,

according to the risk, should be fixed to the roof of the structure.

Each separate structure protected as above should be equipped with twice the number of

downconductors recommended in Clause 4.12.

7.5.4.4 Strikes to the sides of buildings

Consideration should be given to providing an array of vertical conductors to protect the

sides of buildings. These conductors should be spaced every 10 m and be connected to the

air terminal network (top) and earth termination network (bottom) of the LPS.

7.5.4.5 Vertical conductors

A structure or a group of structures of small horizontal dimensions may be protected by one

or more vertical lightning conductors (see Clause 4.4).

7.5.4.6 Below-ground structures

A structure that is wholly below ground and not connected to any services above ground

can be protected by an air terminal network as described in Clause 7.5.4.2 by virtue of the

fact that soil has an impulse breakdown strength that can be taken into account when the

risk of flashover from the protection system to the structure to be protected, including its

services, is being determined. Where the depth of burying is adequate, the air terminal

network may be replaced by a network of earthing strips arranged on the surface.

Where the underground structure has a reinforced concrete roof at or immediately below

soil level, the reinforcement may be used as a protection system provided that the

reinforcement is welded so that rectangular electrical conducting paths are formed with

sides not exceeding 2 m in length.

Where the underground structure has a roof that is not reinforced or where the

reinforcement is not electrically continuous, a buried conductor network located above the

structure and buried not less than 500 mm below the soil level may be used.

Where the structure is such that protection cannot be provided by use of the reinforcement

and the depth of soil above the roof is less than 500 mm, air terminals may be mounted on

suitable bases above the structure at soil level and interconnected by a roof conduction

network of closed mesh of between 3 m and 8 m.

7.5.4.7 Interconnection of earth terminations

The earth terminations of the earth protective system should be interconnected by a ring

conductor. This ring conductor should preferably be buried to a depth of not less than

500 mm and be not less than 2 m from the walls of the structure unless other considerations,

such as the need for bonding other objects to it, testing or risks of corrosion, make it

desirable to leave it exposed. The resistance value of the earth termination network should

be maintained permanently at 10 Ω or less. If this value proves to be unobtainable, the

methods recommended in Clause 4.14 should be adopted, or the ring conductor should be

connected to the ring conductor of one or more neighbouring structures until the above

value is obtained.

7.5.4.8 Bonding of structural metal

All major metal forming part of the structure, including continuous metal reinforcement and

services should be bonded together and connected to the LPS. Such connections should be

made in at least two places and should, as far as is possible, be equally spaced round the

perimeter of the structure at intervals not exceeding 15 m. Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 110: ASNZS 1768-2007

AS/NZS 1768:2007 108

COPYRIGHT

7.5.4.9 Bonding of internal metal

Major metalwork inside the structure should be bonded to the LPS.

7.5.4.10 Electrical conductors entering structure

Electrical conductors entering the structure should be enclosed in metal. The metal

enclosure should be electrically continuous within the structure; it should be earthed at the

point-of-entry outside the structure on the supply side of the service and bonded directly to

the LPS.

7.5.4.11 Electrical conductors connected to overhead electricity supply service line

Where the electrical conductors are connected to an overhead electricity supply service line,

a length of buried cable with metal sheath or armouring should be inserted between the

overhead line and the point-of-entry to the structure, and an SPD, e.g. of the type containing

voltage-dependent resistors, shall be provided at the termination of the overhead line. The

earth terminal of this SPD should be bonded directly to the cable sheath or armouring. The

spark overvoltage of the SPD should not exceed half the breakdown withstand voltage of

the electrical equipment in the structure. In this operation, the appropriate Standard and any

regulations that may apply should be observed.

7.5.4.12 Metal not continuously earthed

Metallic pipes, metallic electrical cable sheaths or metallic armouring, steel ropes, rails or

guides that enter the structure and are not in continuous electrical contact with the earth

should be bonded to the LPS. They should be earthed at the point-of-entry outside the

structure and at two points, one about 75 m away and one a further 75 m away.

7.5.4.13 Adit or shaft

For a buried structure or underground excavation to which access is obtained by an adit or

shaft, the recommendations in Clause 7.5.4.12 as regards extra earthing should be followed

for the adit or shaft at intervals not exceeding 75 m as well as outside the structure.

7.5.4.14 Fences and retaining walls

The metal uprights, components and wires of all fences, and of retaining walls in close

proximity to the structure, should be connected in such a way as to provide continuous

metallic connection between themselves and the LPS. Discontinuous metal wire fencing on

non-conducting supports or wire coated with insulating material should not be employed.

7.5.4.15 Avoidance of tall components

Structures with explosive or highly-flammable contents should not be equipped with tall

components such as spires and flagstaffs or radio antennas on the structure or within 15 m

of the structure. This clearance applies also to the planting of new trees, but structures near

existing trees should be treated in accordance with Clause 6.3.

7.5.4.16 Tests of system

Tests should be carried out in accordance with Clause 8.3 at intervals of not more than two

years. The test equipment used should be certified for use in the particular hazardous area.

In some cases, non-certified testing equipment may be used provided that the location

where the tests are to be conducted has been proven to be free of combustible gases or

vapours.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 111: ASNZS 1768-2007

109 AS/NZS 1768:2007

COPYRIGHT

S E C T I O N 8 I N S T A L L A T I O N A N D

M A I N T E N A N C E P R A C T I C E

8.1 WORK ON SITE

Throughout the period of erection of a structure, all large and prominent masses of

metalwork, such as steel frameworks, scaffolding and cranes, should be effectively

connected to earth. Once work has commenced on the installation of an LPS, an earth

connection should be maintained at all times.

During the construction of overhead electricity supply service lines, overhead equipment

for railway electrification and the like, the danger to persons can be minimized by ensuring

that an earth termination network is installed and properly connected before any conductors

other than earth wires are run out. Once the conductors are run out and insulation installed,

they should not be left ‘floating’ while persons are working on them, but should be

connected to earth in the same manner as when maintenance is being carried out after the

line is commissioned.

8.2 INSPECTION

All LPSs should be inspected after completion, alteration or extension, in order to verify

that they are in accordance with this Standard. A routine inspection should be made at least

every two years. More frequent inspections may be warranted in some circumstances. Such

circumstances include, but are not limited to—

(a) areas subject to severe weather and lightning activity;

(b) structures located in areas where aggressive soil or other conditions may accelerate

corrosion or other aspects of system degradation;

(c) changes in technology use within the structure that may necessitate a review of the

protection means and their continued effectiveness; and

(d) any other time where it is deemed necessary to update the original risk assessment for

lightning damage.

8.3 TESTING

On the completion of the installation or of any modification to it, and at the time of any

maintenance inspection, the resistance to earth of the whole installation and of each earth

termination should be measured, and the electrical continuity of all conductors, bonds and

joints and their mechanical condition verified. The testing should be carried out in

accordance with Appendix B.

Where regular testing during maintenance reveals that the earthing resistance is

substantially unchanged, the frequency of maintenance testing may be reduced to each

alternate inspection.

If the resistance to earth of an LPS, when so determined, exceeds the specified value for the

particular applications the value should be reduced to be in accordance with the

recommendations of this Standard. If the resistance is less than the recommended value but

significantly higher than the previous reading, the cause should be investigated in

accordance with Appendix C.

The condition of the soil, the procedure adopted, details of salting or other soil treatment,

and the results obtained should all be recorded as listed in Clause 8.4.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 112: ASNZS 1768-2007

AS/NZS 1768:2007 110

COPYRIGHT

8.4 RECORDS

The following records should be kept on site, or by the persons responsible for the upkeep

of the installation:

(a) Scale drawings showing the nature, dimensions and position of all component parts of

the LPS.

(b) The nature of the soil and any special earthing arrangements.

(c) Date and particulars of salting, if used.

(d) Test conditions, date and results in accordance with Clause 8.3.

(e) Alterations, additions or repairs to the system.

(f) The name and contact details of the persons responsible for the installation or for its

upkeep.

NOTE: Detection of the occurrence of lightning flashes to the structure and the magnitude of the

discharge current may be estimated by magnetic links, magnetic tape strips or other current

monitoring devices. While the use of instruments to count the number of strikes intercepted by

the protection system is highly recommended, in practice, this may be impractical to achieve on

multiple downconductor LPSs.

8.5 MAINTENANCE

The general recommendations of this Standard provide, as one of their objectives, LPSs that

do not require a lot of maintenance. Nevertheless, some system components will lose their

effectiveness over time because of weathering, corrosion, and stroke damage. Both physical

and electrical characteristics of the LPS must be maintained to ensure compliance with the

design requirements.

The periodic inspection and tests described in Clauses 8.2 and 8.3 will indicate what

maintenance, if any, should be undertaken. Particular attention should be paid to earthing,

to any evidence of corrosion and to any alterations or extensions to the structure that may

affect the LPS. Examples of such alterations or extensions are as follows:

(a) Changes in the use of a building.

(b) Installation of fuel oil storage tanks.

(c) The erection of radio and television antennas.

(d) Installation or alteration to the electrical, telecommunications or computing facilities

within, or closely connected to, the building.

A good maintenance program should also contain provision for the following:

(i) Inspection of all system components.

(ii) Tightening of all accessible clamps and splices.

(iii) Measurement of system resistance, including earth resistance of terminals.

(iv) Inspection or testing of SPDs.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 113: ASNZS 1768-2007

111 AS/NZS 1768:2007

COPYRIGHT

APPENDIX A

EXAMPLES OF LIGHTNING RISK CALCULATIONS

(Informative)

A1 INTRODUCTION

A number of lightning risk calculations have been included in this Appendix to illustrate

different structures and risk categories.

The risk calculation examples are:

(a) Example 1—40 m office block.

(b) Example 2—Darwin hotel.

(c) Example 3—Historic church.

(d) Example 4—Remote pump station.

(e) Example 5—Two storey house.

The front page of the Microsoft® Excel spreadsheet file LIGHTNING RISK.XLS has been

reproduced in Paragraphs A2.1 to A2.5 for each of these examples.

In addition to this, all the workings of the 40 m office block example have been included in

Paragraph A3.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 114: ASNZS 1768-2007

COPYRIGHT

112 AS/NZS 1768:2007

A2

S

AM

PL

E S

PR

EA

DS

HE

ET

CA

LC

UL

AT

ION

S

A2

.1

Ex

am

ple

1—

40

metr

e h

igh

off

ice b

lock

(R)

(Ra)

(Rd)

Sta

nd

ard

s A

ustr

alia

Versio

n 3

.0D

ate

: 28/1

/2006 0.0

0E

+0

0

4.8

1E

-06

0.0

0E

+0

0

0.0

0E

+0

0

Dir

ect

Str

ike

Ris

k

No

Tra

nsfo

rmer

at

Str

uctu

re

1.0

7E

-05

Ove

rall

Ris

k

L

oss o

f H

um

an L

ife

L

oss o

f E

ssential S

erv

ices

0.0

0E

+0

0

4.8

1E

-06

0.0

0E

+00

Ind

irect

Str

ike

Ris

k

(Ri)

0.0

0E

+0

0

L

oss o

f C

ultura

l H

erita

ge

Ac

ce

pta

ble

Ris

k

1.0

E-0

5

E

conom

ic L

oss

1.0

E-0

3

1.0

E-0

3

Ca

lcu

late

d R

isk

0.0

0E

+00

3.1

6E

-05

1.0

E-0

3

40

m O

ffic

e B

loc

kS

tru

ctu

re

Id

en

tifi

ca

tio

n

0

Accepta

ble

Ris

k o

f

Econom

ic L

osses

Se

rvic

e L

ines

Po

wer

Lin

eC

ate

go

ry 1

- L

oss o

f H

um

an

Lif

e

Un

de

rgro

un

d

Lo

ss

Ca

teg

ori

es

0

Ste

p &

Touch P

ote

ntial

Dam

age F

acto

rs

Surg

e P

rote

ction

on A

ll E

quip

ment

0

Un

sc

ree

ne

d

0.3

Cate

go

ry 3

- L

oss o

f C

ult

ura

l H

eri

tag

e

Fire D

am

age

Facto

r

Serv

ice L

ine D

ensity

Num

ber

Cable

Type

Environm

enta

l F

acto

r

Ris

k o

f D

angero

us

Dis

charg

e

Inte

rnal W

irin

g T

ype

Pro

tec

tio

n M

ea

su

res

Urb

an

0.8

No

ne

Fire D

am

age

Facto

rS

pecia

l H

azard

Serv

ice

Cate

go

ry 2

- L

oss o

f E

ssen

tial S

erv

ices

Overv

oltage

Dam

age F

acto

r

Overv

oltage

Dam

age F

acto

r

0.0

51

0

Eff

icie

ncy o

f B

uild

ing

Pro

tection

Ye

sS

urg

e P

rote

ction

at P

oin

t of E

ntr

y

Fire D

am

age

Facto

r

Fire D

am

age

Facto

r

Overv

oltage

Dam

age F

acto

r1

.E-0

3

3

Iso

late

d

00

Un

sc

ree

ne

d

0M

ed

ium

Un

sc

ree

ne

d

En

vir

on

me

nt

0

Length

(m

)

Wid

th (

m)

Str

uctu

re A

ttri

bu

tes

Ris

k o

f F

ire o

r P

hysic

al

Dam

age

1.E

-03

Ris

k A

ssessm

en

t fo

r L

igh

tnin

g P

rote

cti

on

Oth

er

Ov

erh

ead

Serv

ices

Lo

w

20

20

40

Cate

go

ry 4

- E

co

no

mic

Lo

ss

Heig

ht (m

)

2.0

9E

-05

Gro

und fla

sh d

ensity

Str

uctu

re D

ime

nsio

ns

Cable

Type

Oth

er

Un

derg

rou

nd

Serv

ices

Un

sc

ree

ne

d

No

Tra

nsfo

rme

r

Num

ber

Cable

Type

Fire P

rote

ction

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 115: ASNZS 1768-2007

COPYRIGHT

113 AS/NZS 1768:2007

A2

.2

Ex

am

ple

2—

Da

rw

in h

ote

l

(R)

(Ra)

(Rd

)

Sta

nd

ard

s A

ustr

alia

Versio

n 3

.0D

ate

: 28/1

/2006 0.0

0E

+0

0

3.3

6E

-06

0.0

0E

+0

0

0.0

0E

+0

0

Dir

ec

t S

trik

e

Ris

k

No

Tra

nsfo

rmer

at

Str

uctu

re

1.7

0E

-05

Ove

rall R

isk

L

oss o

f H

um

an L

ife

L

oss o

f E

ssential S

erv

ices

0.0

0E

+0

0

3.3

6E

-06

0.0

0E

+00

Ind

ire

ct

Str

ike

Ris

k

(Ri)

3.2

0E

-10

L

oss o

f C

ultura

l H

erita

ge

Ac

ce

pta

ble

Ris

k

1.0

E-0

5

E

conom

ic L

oss

1.0

E-0

3

1.0

E-0

3

Ca

lcu

late

d R

isk

0.0

0E

+00

3.2

6E

-04

1.0

E-0

3

Ho

tel

in D

arw

inS

tru

ctu

re

Id

en

tifi

ca

tio

n

0

Accepta

ble

Ris

k o

f

Econom

ic L

osses

Serv

ice

Lin

es

Po

wer

Lin

eC

ate

go

ry 1

- L

oss o

f H

um

an

Lif

e

Un

de

rgro

un

d

Lo

ss

Ca

teg

ori

es

0

Ste

p &

Touch P

ote

ntial

Dam

age F

acto

rs

Surg

e P

rote

ction

on A

ll E

quip

ment

0

Un

sc

ree

ne

d

0.5

Cate

go

ry 3

- L

oss o

f C

ult

ura

l H

eri

tag

e

Fire D

am

age

Facto

r

Serv

ice L

ine D

ensity

Num

ber

Cable

Typ

e

Environm

enta

l F

acto

r

Ris

k o

f D

angero

us

Dis

cha

rge

Inte

rnal W

irin

g T

ype

Pro

tecti

on

Me

asu

res

Urb

an

0.8

No

ne

Fire D

am

age

Facto

rS

pecia

l H

azard

Serv

ice

Ca

teg

ory

2 -

Lo

ss o

f E

ssen

tial S

erv

ices

Overv

oltage

Dam

age F

acto

r

Overv

oltage

Dam

age F

acto

r

0.1

10

Eff

icie

ncy o

f B

uild

ing

Pro

tection

Ye

sS

urg

e P

rote

ction

at P

oin

t of E

ntr

y

Fire D

am

age

Facto

r

Fire D

am

age

Facto

r

Overv

oltage

Dam

age F

acto

r5

.E-0

3

8

Sim

ila

r H

eig

ht

00

Un

sc

ree

ne

d

0M

ed

ium

Un

sc

ree

ne

d

En

vir

on

men

t

0

Length

(m

)

Wid

th (

m)

Str

uc

ture

Att

rib

ute

s

Ris

k o

f F

ire o

r P

hysic

al

Dam

age

1.E

-03

Ris

k A

ss

es

sm

en

t fo

r L

igh

tnin

g P

rote

cti

on

Oth

er

Ov

erh

ead

Serv

ices

Lo

w

15

15

30

Cate

go

ry 4

- E

co

no

mic

Lo

ss

He

ight (m

)

3.0

9E

-04

Gro

und f

lash d

ensity

Str

uc

ture

Dim

en

sio

ns

Cable

Typ

e

Oth

er

Un

derg

rou

nd

Serv

ices

Un

sc

ree

ne

d

No

Tra

ns

form

er

Num

ber

Cable

Typ

e

Fire P

rote

ction

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 116: ASNZS 1768-2007

COPYRIGHT

114 AS/NZS 1768:2007

A2

.3

Ex

am

ple

3—

His

toric

ch

urch

(R)

(Ra)

(Rd

)

Sta

nd

ard

s A

us

tra

lia

Ve

rs

ion

3.0

Da

te:

28

/1/2

00

6 0.0

0E

+0

0

4.1

3E

-06

0.0

0E

+0

0

1.4

2E

-05

Dir

ec

t S

trik

e

Ris

k

No

Tra

nsfo

rme

r a

t

Str

uctu

re

3.1

3E

-06

Ove

rall R

isk

L

oss o

f H

um

an

Life

L

oss o

f E

sse

ntia

l S

erv

ice

s0

.00

E+

00

4.1

3E

-06

0.0

0E

+0

0

Ind

ire

ct

Str

ike

Ris

k

(Ri )

0.0

0E

+0

0

L

oss o

f C

ultu

ral H

eri

tag

e

Ac

ce

pta

ble

Ris

k

1.0

E-0

5

E

co

no

mic

Lo

ss

1.0

E-0

3

1.0

E-0

3

Ca

lcu

late

d R

isk

1.4

2E

-05

3.1

3E

-06

1.0

E-0

3

His

toric

Ch

urch

Str

uctu

re Id

en

tifi

cati

on

0.5 A

ccep

tab

le R

isk o

f

Eco

no

mic

Lo

sse

s

Se

rvic

e L

ine

s

Po

we

r L

ine

Ca

teg

ory

1 -

Lo

ss

of

Hu

ma

n L

ife

Un

de

rgro

un

d

Lo

ss

Ca

teg

ori

es

0

Ste

p &

To

uch

Po

ten

tial

Dam

ag

e F

acto

rs

Su

rge

Pro

tection

on A

ll E

qu

ipm

en

t

0

Un

sc

ree

ne

d

0.1

Ca

teg

ory

3 -

Lo

ss

of

Cu

ltu

ral H

eri

tag

e

Fir

e D

am

age

Fa

cto

r

Se

rvic

e L

ine

De

nsity

Num

be

r

Cab

le T

yp

e

En

vir

on

me

nta

l F

acto

r

Ris

k o

f D

an

gero

us

Dis

ch

arg

e

Inte

rna

l W

irin

g T

yp

e

Pro

tec

tio

n M

ea

su

res

Urb

an

0.8

No

ne

Fir

e D

am

age

Fa

cto

rS

pecia

l H

aza

rdS

erv

ice

Ca

teg

ory

2 -

Lo

ss o

f E

ss

en

tia

l S

erv

ice

s

Overv

olta

ge

Da

ma

ge

Fa

cto

r

Overv

olta

ge

Da

ma

ge

Fa

cto

r

0.0

05

10

Eff

icie

ncy o

f B

uild

ing

Pro

tectio

nY

es

Surg

e P

rote

ctio

n

at P

oin

t of

En

try

Fir

e D

am

ag

e

Fa

cto

r

Fir

e D

am

ag

e

Fa

cto

r

Ove

rvo

lta

ge

Da

ma

ge

Fa

cto

r1

.E-0

5

1

Sim

ila

r H

eig

ht

00

Un

sc

ree

ne

d

0H

igh

Un

sc

ree

ne

d

En

vir

on

me

nt

0

Le

ng

th (

m)

Wid

th (

m)

Str

uc

ture

Att

rib

ute

s

Ris

k o

f F

ire

or

Ph

ysic

al

Da

ma

ge

1.E

-03

Ris

k A

sse

ssm

en

t fo

r L

igh

tnin

g P

rote

cti

on

Oth

er

Ov

erh

ea

d S

erv

ice

s

Lo

w

40

40

13

0

Ca

teg

ory

4 -

Ec

on

om

ic L

oss

He

igh

t (m

)

5.0

0E

-09

Gro

un

d f

lash

de

nsity

Str

uc

ture

Dim

en

sio

ns

Cab

le T

yp

e

Oth

er

Un

de

rgro

un

d S

erv

ice

s

Un

sc

ree

ne

d

No

Tra

ns

form

er

Num

be

r

Cab

le T

yp

e

Fir

e P

rote

ctio

n

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 117: ASNZS 1768-2007

COPYRIGHT

115 AS/NZS 1768:2007

A2

.4

Ex

am

ple

4—

Rem

ote

pu

mp

sta

tio

n

(R)

(Ra)

(Rd)

Sta

nd

ard

s A

us

tra

lia

Ve

rs

ion

3.0

Da

te:

28

/1/2

00

6 0.0

0E

+0

0

7.4

3E

-10

2.9

7E

-09

0.0

0E

+0

0

Dir

ec

t S

trik

e

Ris

k

Ye

s

Tra

nsfo

rme

r a

t

Str

uctu

re

2.9

9E

-09

Ove

rall

Ris

k

Lo

ss o

f H

um

an

Life

Lo

ss o

f E

sse

ntia

l S

erv

ice

s2

.06

E-0

5

7.4

4E

-10

2.0

6E

-05

Ind

ire

ct

Str

ike

Ris

k

(Ri)

8.3

2E

-13

Lo

ss o

f C

ultu

ral H

eri

tage

Ac

ce

pta

ble

Ris

k

1.0

E-0

5

Eco

no

mic

Lo

ss

1.0

E-0

3

1.0

E-0

3

Ca

lcu

late

d R

isk

0.0

0E

+0

0

3.7

4E

-07

1.0

E-0

3

Rem

ote

Pu

mp

Sta

tio

nS

tru

ctu

re Id

en

tifi

cati

on

0

Acce

pta

ble

Ris

k o

f

Eco

no

mic

Lo

sse

s

Se

rvic

e L

ine

s

Po

we

r L

ine

Ca

teg

ory

1 -

Lo

ss

of

Hu

ma

n L

ife

Ov

erh

ea

d

Lo

ss C

ate

go

rie

s

0

Ste

p &

To

uch P

ote

ntia

l

Da

ma

ge

Facto

rs

Su

rge

Pro

tectio

n

on A

ll E

qu

ipm

ent

0

Un

sc

ree

ne

d

0.2

Ca

teg

ory

3 -

Lo

ss

of

Cu

ltu

ral H

eri

tag

e

Fir

e D

am

ag

e

Fa

cto

r

Se

rvic

e L

ine D

en

sity

Nu

mb

er

Ca

ble

Typ

e

En

vir

onm

en

tal F

acto

r

Ris

k o

f D

an

ge

rous

Dis

ch

arg

e

Inte

rnal W

irin

g T

ype

Pro

tec

tio

n M

eas

ure

s

Ru

ral

0

No

ne

Fir

e D

am

ag

e

Fa

cto

rS

pe

cia

l H

aza

rdS

erv

ice

Ca

teg

ory

2 -

Lo

ss o

f E

sse

nti

al

Se

rvic

es

Ove

rvo

ltag

e

Da

ma

ge

Fa

cto

r

Ove

rvo

ltag

e

Da

ma

ge

Fa

cto

r

01

Eff

icie

ncy o

f B

uild

ing

Pro

tectio

nY

es

Su

rge

Pro

tectio

n

at P

oin

t o

f E

ntr

y

Fire

Dam

ag

e

Facto

r

Fire

Dam

ag

e

Facto

r

Ove

rvolta

ge

Da

ma

ge F

acto

r1

.E-0

4

2

Iso

late

d

0.0

10

.1

Un

sc

ree

ne

d

0L

ow

Un

sc

ree

ne

d

En

vir

on

me

nt

0

Le

ng

th (

m)

Wid

th (

m)

Str

uctu

re A

ttri

bu

tes

Ris

k o

f F

ire o

r P

hysic

al

Da

mag

e

1.E

-03

Ris

k A

sses

sm

en

t fo

r L

igh

tnin

g P

rote

cti

on

Oth

er

Ov

erh

ea

d S

erv

ice

s

Lo

w

3 3 3

Ca

teg

ory

4 -

Ec

on

om

ic L

os

s

He

igh

t (m

)

3.7

1E

-07

Gro

un

d f

lash

de

nsity

Str

uc

ture

Dim

en

sio

ns

Ca

ble

Typ

e

Oth

er

Un

de

rgro

un

d S

erv

ices

Un

sc

ree

ne

d

No

Tra

ns

form

er

Nu

mb

er

Ca

ble

Typ

e

Fir

e P

rote

ctio

n

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 118: ASNZS 1768-2007

COPYRIGHT

116 AS/NZS 1768:2007

A2

.5

Ex

am

ple

5—

Tw

o s

torey

ho

use

(R)

(Ra)

(Rd

)

Sta

nd

ard

s A

us

tra

lia

Ve

rs

ion

3.0

Da

te:

28

/1/2

00

6 0.0

0E

+0

0

1.6

5E

-06

0.0

0E

+0

0

0.0

0E

+0

0

Dir

ec

t S

trik

e

Ris

k

No

Tra

nsfo

rme

r a

t

Str

uctu

re

5.7

9E

-06

Ov

era

ll R

isk

Lo

ss o

f H

um

an

Life

Loss o

f E

ssen

tial S

erv

ices

0.0

0E

+0

0

2.7

2E

-06

0.0

0E

+00

Ind

ire

ct

Str

ike

Ris

k

(Ri)

1.0

7E

-06

Lo

ss o

f C

ultu

ral H

eri

tag

e

Ac

ce

pta

ble

Ris

k

1.0

E-0

5

Eco

no

mic

Lo

ss

1.0

E-0

3

1.0

E-0

3

Ca

lcu

late

d R

isk

0.0

0E

+00

8.0

7E

-04

1.0

E-0

3

Tw

o S

tore

y H

ou

se

Str

uc

ture

Id

en

tifi

ca

tio

n

0

Acce

pta

ble

Ris

k o

f

Eco

no

mic

Lo

sse

s

Se

rvic

e L

ine

s

Po

wer

Lin

eC

ate

go

ry 1

- L

oss o

f H

um

an

Lif

e

Ov

erh

ea

d

Lo

ss

Ca

teg

ori

es

0

Ste

p &

To

uch

Po

ten

tia

l

Dam

ag

e F

acto

rs

Su

rge

Pro

tectio

n

on A

ll E

quip

ment

0

Un

sc

ree

ne

d

0.3

Cate

go

ry 3

- L

oss

of

Cu

ltu

ral

Heri

tag

e

Fir

e D

am

ag

e

Fa

cto

r

Se

rvic

e L

ine

De

nsity

Nu

mb

er

Ca

ble

Typ

e

En

vir

on

me

nta

l F

acto

r

Ris

k o

f D

an

ge

rou

s

Dis

ch

arg

e

Inte

rna

l W

irin

g T

yp

e

Pro

tec

tio

n M

ea

su

res

Su

bu

rba

n

0

No

ne

Fir

e D

am

ag

e

Fa

cto

rS

pe

cia

l H

aza

rdS

erv

ice

Cate

go

ry 2

- L

oss

of

Ess

en

tia

l S

erv

ices

Ove

rvo

lta

ge

Da

ma

ge

Fa

cto

r

Ove

rvo

lta

ge

Da

ma

ge

Fa

cto

r

0.0

51

Eff

icie

ncy o

f B

uild

ing

Pro

tectio

nN

oS

urg

e P

rote

ctio

n

at

Po

int

of

En

try

Fir

e D

am

age

Fa

cto

r

Fir

e D

am

age

Fa

cto

r

Overv

olta

ge

Da

ma

ge

Fa

cto

r1

.E-0

4

2

Lo

we

r H

eig

ht

00

Un

sc

ree

ne

d

1H

igh

Un

sc

ree

ne

d

En

vir

on

me

nt

0

Le

ng

th (

m)

Wid

th (

m)

Str

uc

ture

Att

rib

ute

s

Ris

k o

f F

ire

or

Ph

ysic

al

Da

ma

ge

1.E

-03

Ris

k A

sse

ssm

en

t fo

r L

igh

tnin

g P

rote

cti

on

Oth

er

Ov

erh

ead

Se

rvic

es

Lo

w

20

30

12

Ca

teg

ory

4 -

Ec

on

om

ic L

os

s

He

igh

t (m

)

8.0

1E

-04

Gro

un

d f

lash

de

nsity

Str

uc

ture

Dim

en

sio

ns

Ca

ble

Typ

e

Oth

er

Un

derg

rou

nd

Serv

ices

Un

sc

ree

ne

d

No

Tra

ns

form

er

Nu

mb

er

Ca

ble

Typ

e

Fir

e P

rote

ction

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 119: ASNZS 1768-2007

117 AS/NZS 1768:2007

COPYRIGHT

117

A3 SAMPLE BY-HAND CALCULATION—40 METRE HIGH OFFICE BLOCK

The following calculates the risk of lightning damage to a structure and its equipment

outlined in initial work by IEC Committee TC 81. One power line and any number of

overhead and underground service lines are considered. Selectable parameters have been

tailored for Australian and New Zealand conditions.

Parameter Example value

Lightning activity

Ng Ng = 3 Ground strike density in ground strikes per km2 per year

STRUCTURE

L L = 20 m Structure length in metres

W W = 20 m Structure width in metres

H H = 40 m Structure height in metres

Cd Cd = 1.0 Environmental factor for surrounding object height (direct strikes to structure)

Structure in large area of structures or trees of the same height or greater e.g. typical building in CBD, or shed in an industrial area 0.25

Structure surrounded by smaller structures. e.g. tall building in urban area 0.5

Isolated structure with no other structures or objects within a distance of 3 × height from the structure. e.g. structure in a rural area 1

Isolated structure on hilltop or knoll. e.g. communications site 2

Dm Dm = 250 m Distance from structure that a lightning strike to ground creates a magnetic field which may be great enough to induce an overvoltage exceeding the impulse level of internal equipment.

Fixed factor 250 m

Cs Cs = 0.01 Correction factor for surrounding area. (Density factor relating to service drops)

CBD 0

Urban 0.1

Suburban 0.5

Rural 1

Ph Ph = 0.01 Probability that lightning will cause a shock to animals or human beings outside the structure due to dangerous step and touch potentials.

Fixed factor 10−2

Pg Pg = 10−5 Probability that lightning will cause a shock to animals or human beings inside the structure due to dangerous step and touch potentials.

Fixed factor 10−5

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 120: ASNZS 1768-2007

AS/NZS 1768:2007 118

COPYRIGHT

118

Parameter Example value

Pf Pf = 0.001 Probability that a dangerous discharge will initiate a fire, explosion, mechanical destruction or chemical release.

Explosive high risk of explosion (petrochemical plant) 1

High risk of mechanical and thermal effects (High or significant risk of fire or mechanical damage, roof of combustible material, e.g. thatched roof) 10−1

Medium risk of mechanical and thermal effects (Significant use of combustible building material, e.g. timber frame; OR risk of mechanical damage, e.g. significant masonry dislodged) 10−2

Low risk of mechanical and thermal effects (eg. modern reinforced concrete building) 10−3

Negligible risk of mechanical and thermal effects (all metal structure) 0

Ps Ps = 0.2 Probability of a dangerous discharge based on structure type

High

(Brick, masonry, flammable material, timber or non-conducting material, unprotected roof installations with electrical lines to inside, e.g. antennae) 1

Medium

(Continuous reinforced concrete or steel columns or downconductors. Maximum spacing 20 m) 0.2

Low

(all metal construction) 0.01

Pi Pi = 1 Probability of a dangerous discharge based on internal wiring type

Unscreened wiring 1

Continuously screened wiring 0.1

EQUIPMENT

kw kw = 1 Correction factor for impulse level of equipment.

Fixed factor 1

(applies to

impulse level

of 1.5 kV)

CONDUCTIVE SERVICE LINES

Assumes one or no power line and it is either overhead or underground. The quantity of overhead

and underground service lines in separate routes must be selected. The length of service lines is

determined based on ‘rural’, ‘urban’, ‘suburban’ or ‘CBD’ situation. Assumes there is no adjacent

structure connected by a service line.

Power line

Pl Pl = 2 Power line type

Overhead 1

Underground 2

None 0 Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 121: ASNZS 1768-2007

119 AS/NZS 1768:2007

COPYRIGHT

119

Parameter Example value

Pe0 Pe0 = 1 Probability of dangerous discharge based on external wiring type

Unscreened wiring 1

Screened cable with screen earthed or wiring in continuous metal conduit that is earthed 0.4

Ct0 Ct0 = 1 Correction factor for transformer

LV line, no transformer 1

MV line with HV/LV transformer or isolation transformer 0.25

Overhead service line

noh noh = 0 Number of overhead service lines in separate routes

Pe1 Pe1 = 1 Probability of dangerous discharge based on external wiring type

Unscreened wiring 1

Screened cable with screen earthed or wiring in continuous metal conduit that is earthed 0.4

Fibre optic lines without metal conductors 0

ρ 1 ρ 1 = 100 Ω m Soil resistivity

Fixed factor 100 Ω × m

Hcl Hcl = 7 m Height of conductors above ground

Fixed value 7 m

L1 L1 = 100 m Length of line to the structure from the last distribution node

CBD 0 m

Urban 100 m

Suburban 500 m

Rural 1000 m

Assume there is no adjacent structure

1a1 1a1 = 0 m Length of adjacent structure

wa1 wa1 = 0 m Width of adjacent structure

ha1 ha1 = 0 m Height of adjacent structure

Ct1 Ct1 = 1 Correction factor for transformer

Fixed factor 1 (no isolation transformer)

Conductive underground services—Electrical services e.g. Communication lines

nug nug = 0 Number of underground service lines in separate routes

Pe2 Pe2 = 1 Probability of dangerous discharge based on external service type

Unscreened wiring 1

Screened cable with screen earthed or wiring in continuous metal conduit that is earthed 0.4

ρ 2 ρ 2 = 100 Ω m Soil resistivity

Fixed factor 100 Ω × m Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 122: ASNZS 1768-2007

AS/NZS 1768:2007 120

COPYRIGHT

120

Parameter Example value

L2 L2 = 100 m Length of line to the structure from the last distribution node

CBD 0 m

Urban 100 m

Suburban 500 m

Rural 1000 m

Assume there is no adjacent structure

1a2 1a2 = 0 m Length of adjacent structure

wa2 wa2 = 0 m Width of adjacent structure

ha2 ha2 = 0 m Height of adjacent structure

Ct2 Ct2 = 1 Correction factor for transformer

Fixed factor 1 (no isolation transformer)

ACCEPTABLE RISK AND DAMAGE FACTORS

Damage category 1—Loss of human life

Ra1 Ra1 = 10−5 Acceptable risk. Probability of loss of human life per year

Fixed value for loss of human life 10−5

kh1 kh1 = 10 Increasing factor applied to damage factor for fire and overvoltage when risk of loss of human life is aggravated by special hazards

Low level of panic (building with less than three floors and less than 100 people) 1

Difficulty of evacuation, immobilized people 5

Average level of panic (sport or cultural structure with between 100 and 1000 people) 10

High level of panic (theatres, concert halls, cultural and sport events with more than 1000 people) 100

Hazards for surroundings or environment 200

Contamination of surroundings or environment 500

δh1 δh1 = 0.01 Damage factor for step and touch potential outside structure

Fixed value 0.01

δg1 δg1 = 0.0001 Damage factor for step and touch potential inside structure

Fixed value 0.0001

δf1 δf1 = 0.05 Damage factor for fire

Loss of human life

Hospitals, hotels, public buildings 0.1

Industrial properties, properties for commercial activities, schools, offices 0.05

Public entertainment buildings, churches, museums, temporary structure 0.005

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 123: ASNZS 1768-2007

121 AS/NZS 1768:2007

COPYRIGHT

121

Parameter Example value

δo1 δo1 = 0 Damage factor for overvoltages

Loss of human life

Hospitals 0.0005

Industrial properties with risk of explosion 0.05

Other structures 0

Damage category 2—Loss of essential service to the public

Ra2 Ra2 = 10−3 Acceptable risk. Probability of loss of essential service to the public per year

Fixed value for loss of service to the public 10−3

δf2 δf2 = 0 Damage factor for fire

Unacceptable loss of service to the public

Gas supply 0.2

Water supply 0.1

Radio and television 0.08

Telecommunications 0.06

Power supply, railway 0.04

No essential service function associated with the structure 0

δo2 δo2 = 0 Damage factor for overvoltages

Unacceptable loss of service to the public

Gas supply 0.02

Water supply 0.01

Radio and television 0.005

Telecommunications 0.003

Power supply, railway 0.001

No essential service function associated with the structure 0

Damage category 3—Loss of cultural heritage (it is assumed there are no electronic devices

inside)

Ra3 Ra3 = 10−3 Acceptable risk. Probability of loss of cultural heritage per year

Fixed value for loss of cultural heritage 10−3

δf3 δf3 = 0 Damage factor for fire

Loss of irreplaceable cultural heritage

Typical value 0.5

No cultural heritage value 0

Damage category 4—Economic loss

Ra4 Ra4 = 10−3 Acceptable risk for economic loss. Probability of economic loss per year

Depends on structure owners requirement

Range available is 0.1, 0.01, 0.001, 0.0001, 0.00001 Suggest 0.001

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 124: ASNZS 1768-2007

AS/NZS 1768:2007 122

COPYRIGHT

122

Parameter Example value

kh4 kh4 = 1 Increasing factor applied to damage factor for fire and overvoltage when risk of loss of human life is aggravated by special hazards

Fixed value 1 (no special

hazard factor)

δh4 δh4 = 0 Damage factor for step and touch potential outside structure

Fixed value for agricultural properties with animals around the structure 0.01

Otherwise 0

δg4 δg4 = 0 Damage factor for step and touch potential inside structure

Fixed value for agricultural properties with animals inside the structure 0.0001

Otherwise 0

δf4 δf4 = 0.3 Damage factor for fire

Economic loss

δf = average value of possible loss/total value structure, contents and activities

Typical values for economic loss:

Hospitals, hotels, industrial properties, museums 0.5

Properties for public use, agricultural properties 0.4

Offices, schools 0.3

Commercial activities, public entertainment 0.2

Prisons, churches 0.1

No economic loss 0

δo4 δo4 = 0.001 Damage factor for overvoltages

Economic loss

δo = average value of possible loss/total value structure, contents and activities

Typical values for economic loss:

Hospitals, hotels, industrial properties, museums 0.005

Properties for public use, agricultural properties, offices, schools 0.001

Commercial activities, public entertainment 0.0001

Prisons, churches 0.00001

No economic loss 0

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 125: ASNZS 1768-2007

123 AS/NZS 1768:2007

COPYRIGHT

123

Parameter Example value

LIGHTNING PROTECTION MEASURES

E E = 0.8 Efficiency of lightning protection system on the structure. Takes into account interception and sizing efficiencies

Level I 98%

Level II 95%

Level III 90%

Level IV 80%

No protection 0%

Assumes surge protection is applied to all OR none of the internal equipment of the structure

k2 k2 = 1 Reduction factor for isolation equipment on internal equipment

Fixed factor 1 (no isolation transformer on internal equipment)

k3 k3 = 1 Reduction factor for surge protection device on input of equipment

Surge protection device on input of equipment 0.01

No surge protection device on input of equipment 1.0

kf kf = 1 Reduction factor for fire protection measures

No protection measures 1.0

Extinguishers, hydrants, manual alarm installations, fixed manually operated extinguishing installations 0.8

Protection escape routes, fireproof compartments, automatic alarms protected from overvoltage, automatically operated extinguishers, operating time of escape routes less than 10 minutes 0.6

Conductive service lines—assumes surge protection must be applied to all OR none of the

service lines

k4 k4 = 1 Reduction factor for isolation equipment at entry point of service line

Fixed factor 1 (no isolation

transformer on line entry point)

k5 k5 = 0.01 Reduction factor for surge protection device on entry point of service line

Surge protection device on entry point of line 0.01

No surge protection device on entry point of line 1.0

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 126: ASNZS 1768-2007

COPYRIGHT

124 AS/NZS 1768:2007

CA

LC

UL

AT

ION

S

Pa

ra

mete

r

Ex

am

ple

va

lue

Dir

ect

strik

es

to s

tru

ctu

re

Ad =

L ×

W +

6 ×

H ×

(L

+ W

) +

9 ×

π ×

H2

Ad =

0.0

55

km

2

Co

llecti

on

are

a i

n s

qu

are

metr

es

for

dir

ect

stri

kes

to t

he s

tru

ctu

re.

Base

d o

n i

nte

rsecti

on

o

f g

rou

nd

su

rface a

nd

a l

ine w

ith

slo

pe o

f 1

/3

that

tou

ch

es

the t

op

of

the s

tru

ctu

re

Nd =

Ng ×

Ad ×

Cd

Nd =

0.1

65

7

Av

era

ge n

um

ber

of

dir

ect

stri

kes

to t

he

stru

ctu

re p

er

year

Ind

irect

strik

es

to s

tru

ctu

re

Am

= L

× W

+ 2

× D

m ×

(L

+ W

) +

π ×

Dm

2 –

Ad

A

rea o

f in

flu

en

ce f

or

gen

era

tio

n o

f o

verv

olt

ag

es

Am

= i

f (A

m <

0,

0 k

m2 ,

Am

) A

m =

0.1

62

km

2

Lim

it m

inim

um

valu

e t

o z

ero

if

heig

ht

of

stru

ctu

re i

s to

o l

arg

e

Nm

= N

g ×

Am

N

m =

0.4

84

5

Av

era

ge n

um

ber

of

stri

kes

dir

ect

to g

rou

nd

or

to g

rou

nd

ed

ob

jects

near

the s

tru

ctu

re p

er

year

cau

sin

g o

verv

olt

ag

es

OV

ER

HE

AD

SE

RV

ICE

LIN

E

no

hp =

if

(Pl =

1,

1,

0)

no

hp =

0

Calc

ula

te n

um

ber

of

ov

erh

ead

po

wer

serv

ice

lin

es

Dir

ect

strik

es

to o

verh

ea

d l

ine

Dc1 =

3 ×

Hc1

Dc1 =

21

m

Late

ral

dis

tan

ce f

or

ov

erh

ead

lin

e

Lc1 =

L1 –

3 ×

H –

3 ×

ha1

Lc1 =

−2

0 m

E

ffecti

ve l

en

gth

fo

r o

verh

ead

lin

e

Lc1 =

if

(Lc1 ≥

0 m

, L

c1,

0 m

) L

c1 =

0 m

Ac1 =

2 ×

Dc1 ×

Lc1

Ac1 =

0 k

m2

Co

llecti

on

are

a f

or

ov

erh

ead

lin

e

Aa1 =

1a1 ×

wal +

6 ×

hal ×

(1

a1 +

wa1)

+ 9

× π

×h

al2

A

a1 =

0 k

m2

Co

llecti

on

are

a f

or

dir

ect

stri

kes

to a

dja

cen

t st

ructu

re

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 127: ASNZS 1768-2007

COPYRIGHT

125 AS/NZS 1768:2007

CA

LC

UL

AT

ION

S

Pa

ra

mete

r

Ex

am

ple

va

lue

Nc1

p =

Ng ×

(A

c1 +

Aa1) ×

Ct0

× C

s N

c1

p =

0

Av

era

ge n

um

ber

of

stri

kes

dir

ect

to t

he

ov

erh

ead

po

wer

lin

e p

er

year

that

are

p

ote

nti

all

y d

an

gero

us

Nc1 =

Ng ×

(A

c1 +

Aa1) ×

Ct1

× C

s N

c1 =

0

Av

era

ge n

um

ber

of

stri

kes

dir

ect

to o

ther

co

nd

ucti

ve o

verh

ead

lin

e p

er

year

that

are

p

ote

nti

all

y d

an

gero

us

Ind

irect

strik

es

to o

verh

ea

d l

ine

D1

1 =

50

0 ×

0.5

0.5

1m

ohm

ρ−

××

D

11 =

50

00

m

Late

ral

dis

tan

ce f

or

ind

uced

ov

erv

olt

ag

es

du

e

to s

trik

es

to g

rou

nd

near

the l

ine

A1

1 =

2 ×

D1

1 ×

L1

A1

1 =

1 k

m2

Co

llecti

on

are

a f

or

ind

uced

ov

erv

olt

ag

es

du

e

to s

trik

es

to g

rou

nd

near

the o

verh

ead

lin

e

N1

1p =

Ng ×

A1

1 ×

Ct0

× C

s N

11

p =

0.3

0

Av

era

ge n

um

ber

of

stri

kes

to g

rou

nd

near

the

ov

erh

ead

po

wer

lin

e p

er

year

that

cau

se

po

ten

tiall

y d

an

gero

us

ind

uced

vo

ltag

es

N1

1 =

Ng ×

A1

1 ×

Ct1

× C

s N

11 =

0.3

0

Av

era

ge n

um

ber

of

stri

kes

to g

rou

nd

near

oth

er

co

nd

ucti

ve o

verh

ead

lin

e p

er

year

that

cau

se p

ote

nti

all

y d

an

gero

us

ind

uced

vo

ltag

es

UN

DE

RG

RO

UN

D S

ER

VIC

E L

INE

nu

gp =

if

(Pl =

2,

1,

0)

nu

gp =

1

Calc

ula

te t

ota

l n

um

ber

of

un

derg

rou

nd

p

ow

er

serv

ice l

ines

Dir

ect

strik

es

to u

nd

erg

ro

un

d s

erv

ice l

ine

Dc2 =

0.2

×

0.5

0.5

2m

ohm

ρ−

××

D

c2 =

2 m

L

ate

ral

dis

tan

ce f

or

un

derg

rou

nd

lin

e

Lc2 =

L2 –

3 ×

H –

3 ×

ha2

Lc2 =

−2

0 m

E

ffecti

ve l

en

gth

fo

r u

nd

erg

rou

nd

lin

e

Lc2 =

if

(Lc2 ≥

0 ×

m,

Lc2,

0 ×

m)

Lc2 =

0 m

Ac2 =

2 ×

Dc2 ×

Lc2

Ac2 =

0 k

m2

Co

llecti

on

are

a f

or

un

derg

rou

nd

lin

e

Aa2 =

1a2 ×

wa2 +

6 ×

ha2 ×

(1

a2 +

wa2)

+ 9

× π

× h

a2

2

Aa2 =

0 k

m2

Co

llecti

on

are

a f

or

dir

ect

stri

kes

to a

dja

cen

t st

ructu

re

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 128: ASNZS 1768-2007

COPYRIGHT

126 AS/NZS 1768:2007

CA

LC

UL

AT

ION

S

Pa

ra

mete

r

Ex

am

ple

va

lue

Nc2

p =

Ng ×

(A

c2 +

Aa2) ×

Ct0

× C

s N

c2

p =

0

Av

era

ge n

um

ber

of

stri

kes

dir

ect

to t

he

un

derg

rou

nd

po

wer

lin

e p

er

year

that

are

p

ote

nti

all

y d

an

gero

us

Nc2 =

Ng ×

(A

c2 +

Aa2) ×

Ct2

× C

s N

c2 =

0

Av

era

ge n

um

ber

of

stri

kes

dir

ect

to o

ther

co

nd

ucti

ve u

nd

erg

rou

nd

li

ne p

er

year

that

are

po

ten

tiall

y d

an

gero

us

Ind

irect

strik

es

to u

nd

erg

ro

un

d s

erv

ice l

ine

D1

2 =

25

0 ×

0.5

0.5

2m

ohm

ρ−

××

D

12 =

25

00

m

Late

ral

dis

tan

ce f

or

ind

uced

ov

erv

olt

ag

es

du

e

to s

trik

es

to g

rou

nd

near

the u

nd

erg

rou

nd

cab

le

A1

2 =

2 ×

D1

2 ×

L2

A1

2 =

0.5

km

2

Co

llecti

on

are

a f

or

ind

uced

ov

erv

olt

ag

es

du

e

to s

trik

es

to g

rou

nd

near

the u

nd

erg

rou

nd

cab

le

N1

2p =

Ng ×

A1

2 ×

Ct0

× C

s N

12

p =

0.1

5

Av

era

ge n

um

ber

of

stri

kes

to g

rou

nd

near

the

un

derg

rou

nd

po

wer

cab

le p

er

year

that

cau

se

po

ten

tiall

y d

an

gero

us

ind

uced

vo

ltag

es

N1

2 =

Ng ×

A1

2 ×

Ct2

× C

s N

12 =

0.1

5

Av

era

ge n

um

ber

of

stri

kes

to g

rou

nd

near

oth

er

un

derg

rou

nd

cab

le p

er

year

that

cau

se

po

ten

tiall

y d

an

gero

us

ind

uced

vo

ltag

es

RIS

K C

AL

CU

LA

TIO

NS

FO

R D

AM

AG

E C

AT

EG

OR

Y 1

– L

oss

of

hu

ma

n l

ife

Ris

k o

f d

an

gero

us

step

an

d t

ou

ch

po

ten

tia

l o

uts

ide s

tru

ctu

re d

ue t

o d

irect

strik

es

to s

tru

ctu

re

k1 =

1 –

E

R

ed

ucti

on

facto

r fo

r st

ructu

re l

igh

tnin

g

pro

tecti

on

sy

stem

Ph

1 =

k1 ×

Ph ×

Ps

Ph

1 =

4 ×

10

-4

Pro

bab

ilit

y o

f d

an

gero

us

step

an

d t

ou

ch

v

olt

ag

es

ou

tsid

e s

tru

ctu

re d

ue t

o d

irect

stri

kes

to u

np

rote

cte

d s

tru

ctu

re

Rh

1 =

Nd ×

Ph

δh

1

Rh

1 =

6.6

28

× 1

0-7

R

isk

of

dan

gero

us

step

an

d t

ou

ch

po

ten

tial

to

hu

man

s o

uts

ide t

he s

tru

ctu

re d

ue t

o d

irect

stri

kes

to t

he s

tru

ctu

re

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 129: ASNZS 1768-2007

COPYRIGHT

127 AS/NZS 1768:2007

CA

LC

UL

AT

ION

S

Pa

ra

mete

r

Ex

am

ple

va

lue

Ris

k o

f p

hy

sica

l d

est

ru

cti

on

du

e t

o f

ire,

ex

plo

sio

n,

mech

an

ica

l d

am

ag

e a

nd

ch

em

ica

l d

isch

arg

e d

ue t

o d

irect

strik

es

to s

tru

ctu

re

Pe0 =

if

(P1 =

0,

0,

Pe0)

Pe0 =

1

Ch

eck

if

there

is

no

po

wer

lin

e.

If t

here

is

no

p

ow

er

lin

e t

hen

set

to z

ero

Pet =

Pe0 +

no

h ×

Pe1 +

nu

g ×

Pe2

Pet =

1

To

tal

part

ial

pro

bab

ilit

y t

hat

ex

tern

al

wir

ing

carr

ies

a s

urg

e

Petc

= i

f (P

et >

1,1

, P

et)

P

etc

= 1

L

imit

part

ial

pro

bab

ilit

y t

o a

max

imu

m o

f 1

Pew

d =

k5 ×

Petc

P

ew

d =

0.0

1

Pro

bab

ilit

y t

hat

ex

tern

al

wir

ing

carr

ies

a

surg

e f

rom

str

uctu

re t

hat

cau

ses

ph

ysi

cal

dam

ag

e

Ps

= k

f ×

Pf ×

(k

1 ×

Ps

+ P

ew

d)

Ps

= 5

× 1

0-5

P

rob

ab

ilit

y a

dir

ect

stri

ke t

o s

tru

ctu

re w

ill

cau

se p

hy

sical

dam

ag

e

Rs1

= N

d ×

Ps ×

δf1

× k

h1

Rs1

= 4

.14

3 ×

10

-6

Ris

k o

f p

hy

sical

dam

ag

e d

ue t

o d

irect

stri

kes

to t

he s

tru

ctu

re

Ris

k o

f ele

ctr

ica

l/ele

ctr

on

ic e

qu

ipm

en

t m

alf

un

cti

on

or f

ail

ure d

ue t

o o

verv

olt

ag

es

fro

m d

irect

strik

es

to t

he s

tru

ctu

re

Pew

do =

kw ×

k2×

k3 ×

k4 ×

k5 ×

Petc

P

ew

do =

0.0

1

Pro

bab

ilit

y t

hat

ex

tern

al

wir

ing

carr

ies

a

surg

e f

rom

str

uctu

re t

hat

cau

ses

a d

am

ag

ing

o

verv

olt

ag

e t

o i

nte

rnal

eq

uip

men

t

Pw =

1 –

(1

– k

1 ×

Ps ×

Pi ×

k2 ×

k3 ×

kw) ×

(1

– P

ew

do)

Pw =

0.0

5

Pro

bab

ilit

y o

f ele

ctr

on

ic f

ail

ure

du

e t

o

ov

erv

olt

ag

es

fro

m d

irect

stri

ke t

o t

he

stru

ctu

re

Rw

1 =

Nd ×

Pw

× δ

o1 ×

kh

1

Rw

1 =

0

Ris

k d

ue t

o f

ail

ure

or

malf

un

cti

on

of

ele

ctr

ical

an

d e

lectr

on

ic e

qu

ipm

en

t d

ue t

o

ov

erv

olt

ag

es

fro

m d

irect

stri

kes

to t

he

stru

ctu

re

Ris

k o

f ele

ctr

ica

l/ele

ctr

on

ic e

qu

ipm

en

t m

alf

un

cti

on

or f

ail

ure d

ue t

o o

verv

olt

ag

es

fro

m i

nd

irect

strik

es

to t

he s

tru

ctu

re

Pm

= k

1 ×

k2 ×

k3 ×

kw

× P

s ×

Pi

Pm

= 0

.04

P

rob

ab

ilit

y a

dir

ect

stri

ke t

o g

rou

nd

near

the

stru

ctu

re w

ill

cau

se a

dam

ag

ing

ov

erv

olt

ag

e

to i

nte

rnal

eq

uip

men

t

Rm

1 =

Nm

× P

m ×

δo

1 ×

kh

1

Rm

1 =

0

Ris

k o

f in

tern

al

eq

uip

men

t fa

ilu

re d

ue t

o a

d

irect

stri

ke t

o g

rou

nd

near

the s

tru

ctu

re

cau

ses

a d

am

ag

ing

ov

erv

olt

ag

e

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 130: ASNZS 1768-2007

COPYRIGHT

128 AS/NZS 1768:2007

CA

LC

UL

AT

ION

S

Pa

ra

mete

r

Ex

am

ple

va

lue

Ris

k o

f d

an

gero

us

tou

ch

po

ten

tia

l in

sid

e s

tru

ctu

re d

ue t

o d

irect

strik

es

to s

erv

ice l

ines

Pc1

p =

no

hp ×

k5 ×

Pe0

Pclp

= 0

P

rob

ab

ilit

y a

dir

ect

stri

ke t

o t

he o

verh

ead

p

ow

er

lin

e w

ill

cau

se a

dam

ag

ing

ov

erv

olt

ag

e

to i

nte

rnal

eq

uip

men

t

Pc1 =

no

h ×

k5 ×

Pe1

Pc1 =

0

Pro

bab

ilit

y a

dir

ect

stri

ke t

o o

ther

ov

erh

ead

li

ne w

ill

cau

se a

dam

ag

ing

ov

erv

olt

ag

e t

o

inte

rnal

eq

uip

men

t

Pc2

p =

nu

gp ×

k5 ×

Pe0

Pc2

p =

0.0

1

Pro

bab

ilit

y a

dir

ect

stri

ke t

o t

he u

nd

erg

rou

nd

p

ow

er

lin

e w

ill

cau

se a

dam

ag

ing

ov

erv

olt

ag

e

to i

nte

rnal

eq

uip

men

t

Pc2 =

nu

g ×

k5 ×

Pe2

Pc2 =

0

Pro

bab

ilit

y a

dir

ect

stri

ke t

o o

ther

un

derg

rou

nd

lin

e w

ill

cau

se a

dam

ag

ing

o

verv

olt

ag

e t

o i

nte

rnal

eq

uip

men

t

Rg

1 =

Pg ×

(N

c1 ×

Pc1 +

Nc2 ×

Pc2 +

Nc1

p ×

Pclp

+ N

c2

p ×

Pc2

p) ×

δg

1

Rg

1 =

0

Ris

k o

f d

an

gero

us

step

an

d t

ou

ch

po

ten

tial

to

hu

man

s in

sid

e t

he s

tru

ctu

re d

ue t

o d

irect

stri

kes

to t

he s

tru

ctu

re

Ris

k o

f fi

re,

ex

plo

sio

n,

mech

an

ica

l d

am

ag

e a

nd

ch

em

ica

l d

isch

arg

e c

au

sed

by

ele

ctr

ica

l/ele

ctr

on

ic e

qu

ipm

en

t m

alf

un

cti

on

or f

ail

ure d

ue t

o o

verv

olt

ag

es

fro

m d

irect

strik

es

to s

erv

ice l

ines

Rc1 =

kf ×

Pf ×

(N

c1 ×

Pc1 +

Nc2 ×

Pc2 +

Nc1

p ×

Pc1

p +

Nc2

p ×

Pc2

p) ×

δf1

× k

h1

Rc1 =

0

Ris

k o

f fi

re,

ex

plo

sio

n,

mech

an

ical

dam

ag

e

an

d c

hem

ical

rele

ase

cau

sed

by

in

tern

al

eq

uip

men

t fa

ilu

re d

ue t

o a

dir

ect

stri

ke t

o

serv

ice l

ines

wh

ich

cau

ses

a d

am

ag

ing

o

verv

olt

ag

e

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 131: ASNZS 1768-2007

COPYRIGHT

129 AS/NZS 1768:2007

CA

LC

UL

AT

ION

S

Pa

ra

mete

r

Ex

am

ple

va

lue

Ris

k o

f ele

ctr

ica

l/ele

ctr

on

ic e

qu

ipm

en

t m

alf

un

cti

on

or f

ail

ure d

ue t

o o

verv

olt

ag

es

fro

m d

irect

strik

es

to s

erv

ice l

ines

Re1 =

kw ×

k2 ×

k3 ×

k4 ×

(N

c1 ×

Pc1 +

Nc2 ×

Pc2 +

Nc2

p ×

Pc2

p) ×

δo

1 ×

kh

1

Re1 =

0

Ris

k o

f in

tern

al

eq

uip

men

t fa

ilu

re d

ue t

o a

d

irect

stri

ke t

o t

he s

erv

ice l

ines

that

cau

ses

a

dam

ag

ing

ov

erv

olt

ag

e

Ris

k o

f ele

ctr

ica

l/ele

ctr

on

ic e

qu

ipm

en

t m

alf

un

cti

on

or f

ail

ure d

ue t

o o

verv

olt

ag

es

fro

m i

nd

irect

strik

es

to s

erv

ice l

ines

Pi1

p =

no

hp ×

kw

× k

2 ×

k3 ×

k4 ×

k5 ×

Peo

Pi1

p =

0

Pro

bab

ilit

y a

n i

nd

irect

stri

ke n

ear

the

ov

erh

ead

po

wer

lin

e w

ill

cau

se a

dam

ag

ing

o

verv

olt

ag

e t

o i

nte

rnal

eq

uip

men

t

Pil =

no

h ×

kw ×

k2 ×

k3 ×

k4 ×

k5 ×

Pel

Pi1

= 0

P

rob

ab

ilit

y a

n i

nd

irect

stri

ke n

ear

oth

er

ov

erh

ead

lin

e w

ill

cau

se a

dam

ag

ing

o

verv

olt

ag

e t

o i

nte

rnal

eq

uip

men

t

Pi2

p =

nu

gp ×

kw

× k

2 ×

k3 ×

k4 ×

k5 ×

Pe0

Pi2

p =

0.0

1

Pro

bab

ilit

y a

n i

nd

irect

stri

ke n

ear

the

un

derg

rou

nd

po

wer

cab

le l

ine w

ill

cau

se a

d

am

ag

ing

ov

erv

olt

ag

e t

o i

nte

rnal

eq

uip

men

t

Pi2

= n

ug ×

kw ×

k2 ×

k3 ×

k4 ×

k5 ×

Pe2

Pi2

= 0

P

rob

ab

ilit

y a

n i

nd

irect

stri

ke n

ear

oth

er

un

derg

rou

nd

cab

le w

ill

cau

se a

dam

ag

ing

o

verv

olt

ag

e t

o i

nte

rnal

eq

uip

men

t

R1

1 =

(N

11 ×

Pi1

+ N

12 ×

Pi2

+ N

11

p ×

Pi1

p +

N1

2p ×

Pi2

p) ×

δo

1 ×

kh

1

R1

1 =

0

Ris

k o

f in

tern

al

eq

uip

men

t fa

ilu

re d

ue t

o a

n

ind

irect

stri

ke n

ear

the s

erv

ice l

ines

that

cau

ses

a d

am

ag

ing

ov

erv

olt

ag

e

To

tal

ris

k (R

1)

Rd

1 =

Rh

1 +

Rs1

+ R

w1

Rd

1 =

4.8

06

× 1

0-6

R

isk

du

e t

o d

irect

stri

kes

to t

he s

tru

ctu

re

Ri1

= R

g1 +

Rc1 +

Rm

1 +

Re1 +

R1

1

Ri1

= 0

R

isk

du

e t

o i

nd

irect

stri

kes

to t

he s

tru

ctu

re

R1 =

Ri1

+ R

d1

R1 =

4.8

06

× 1

0-6

T

ota

l ri

sk f

or

a s

tru

ctu

re d

ue t

o l

igh

tnin

g

stri

kes

R

a1 =

1 ×

10

-5

Accep

tab

le r

isk

Co

mp

are

to

tal

risk

to

accep

tab

le r

isk

. If

to

tal

risk

ex

ceed

s accep

tab

le r

isk

, in

cre

ase

th

e l

ev

el

of

pro

tecti

on

measu

res.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 132: ASNZS 1768-2007

COPYRIGHT

130 AS/NZS 1768:2007

CA

LC

UL

AT

ION

S

Pa

ra

mete

r

Ex

am

ple

va

lue

Ris

k f

acto

rs

prese

nte

d i

n d

iffe

ren

t fo

rm

at

Rt1

= R

h1 +

Rg

1

Rt1

= 6

.63

× 1

0-7

R

isk

of

step

an

d t

ou

ch

vo

ltag

e

Rf1

= R

s1 +

Rc1

Rf1

= 4

.14

3 ×

10

-6

Ris

k d

ue t

o f

ire,

ex

plo

sio

n,

mech

an

ical

dam

ag

e a

nd

ch

em

ical

rele

ase

Ro

1 =

Rw

1 +

Rm

1 +

Re1 +

R1

1

Ro

1 =

0

Ris

k d

ue t

o f

ail

ure

of

inte

rnal

ele

ctr

ical

an

d

ele

ctr

on

ic e

qu

ipm

en

t d

ue t

o o

verv

olt

ag

e

RIS

K C

AL

CU

LA

TIO

NS

FO

R D

AM

AG

E C

AT

EG

OR

Y 2

– L

oss

of

ess

en

tia

l se

rv

ice t

o t

he p

ub

lic

Rs2

= N

d ×

Ps ×

δf2

R

s2 =

0

Ris

k o

f p

hy

sical

dam

ag

e d

ue t

o d

irect

stri

kes

to t

he s

tru

ctu

re

Rc2 =

kf ×

Pf ×

(N

c1 ×

Pc1 +

Nc2 ×

Pc2 +

Nc1

p ×

Pc1

p +

Nc2

p ×

Pc2

p) ×

δf2

R

c2 =

0

Ris

k o

f fi

re,

ex

plo

sio

n,

mech

an

ical

dam

ag

e

an

d c

hem

ical

rele

ase

cau

sed

by

in

tern

al

eq

uip

men

t fa

ilu

re d

ue t

o a

dir

ect

stri

ke t

o

serv

ice l

ines

wh

ich

cau

ses

a d

am

ag

ing

o

verv

olt

ag

e

Rw

2 =

Nd ×

Pw

× δ

o2

Rw

2 =

0

Ris

k d

ue t

o f

ail

ure

or

malf

un

cti

on

of

ele

ctr

ical

an

d e

lectr

on

ic e

qu

ipm

en

t d

ue t

o

ov

erv

olt

ag

es

fro

m d

irect

stri

kes

to t

he

stru

ctu

re

Rm

2 =

Nm

× P

m ×

δo

2

Rm

2 =

0

Ris

k o

f in

tern

al

eq

uip

men

t fa

ilu

re d

ue t

o a

d

irect

stri

ke t

o g

rou

nd

near

the s

tru

ctu

re t

hat

cau

ses

a d

am

ag

ing

ov

erv

olt

ag

e

Re2 =

kw ×

k2 ×

k3 ×

k4 ×

(N

c1 ×

Pc1 +

Nc2 ×

Pc2 +

Nc1

p ×

Pc1

p +

Nc2

p ×

Pc2

p) ×

δo

2

Re2 =

0

Ris

k o

f in

tern

al

eq

uip

men

t fa

ilu

re d

ue t

o a

d

irect

stri

ke t

o t

he s

erv

ice l

ines

that

cau

ses

a

dam

ag

ing

ov

erv

olt

ag

e

R1

2 =

(N

11 ×

Pi1

+ N

12 ×

Pi2

+ N

11

p ×

Pi1

p +

N1

2p ×

Pi2

p) ×

δo

2

R1

2 =

0

Ris

k o

f in

tern

al

eq

uip

men

t fa

ilu

re d

ue t

o a

in

dir

ect

stri

ke n

ear

the s

erv

ice l

ines

that

cau

ses

a d

am

ag

ing

ov

erv

olt

ag

e

Rd

2 =

0 +

Rs2

+ R

w2

Rd

2 =

0

Ris

k d

ue t

o d

irect

stri

kes

to t

he s

tru

ctu

re

Ri2

= R

c2 +

Rm

2 +

Re2 +

R1

2

Ri2

= 0

R

isk

du

e t

o i

nd

irect

stri

kes

to t

he s

tru

ctu

re

R2 =

Ri2

+ R

d2

R2 =

0

To

tal

risk

fo

r a s

tru

ctu

re d

ue t

o l

igh

tnin

g

stri

kes

R

a2 =

1 ×

10

-3

Accep

tab

le r

isk

Co

mp

are

to

tal

risk

to

accep

tab

le r

isk

. If

to

tal

risk

ex

ceed

s accep

tab

le r

isk

, in

cre

ase

th

e l

ev

el

of

pro

tecti

on

measu

res.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 133: ASNZS 1768-2007

COPYRIGHT

131 AS/NZS 1768:2007

CA

LC

UL

AT

ION

S

Pa

ra

mete

r

Ex

am

ple

va

lue

RIS

K C

AL

CU

LA

TIO

NS

FO

R D

AM

AG

E C

AT

EG

OR

Y 3

– L

oss

of

cu

ltu

ra

l h

erit

ag

e

Rs3

= N

d ×

Ps ×

δf3

R

s3 =

0

Ris

k o

f p

hy

sical

dam

ag

e d

ue t

o d

irect

stri

kes

to t

he s

tru

ctu

re

Rc3 =

kf ×

Pf ×

(N

c1 ×

Pc1 +

Nc2 ×

Pc2 +

Nc1

p ×

Pc1

p +

Nc2

p ×

Pc2

p) ×

δf3

R

c3 =

0

Ris

k o

f fi

re,

ex

plo

sio

n,

mech

an

ical

dam

ag

e

an

d c

hem

ical

rele

ase

cau

sed

by

in

tern

al

eq

uip

men

t fa

ilu

re d

ue t

o a

dir

ect

stri

ke t

o

serv

ice l

ines

that

cau

ses

a d

am

ag

ing

o

verv

olt

ag

e

Rd

3 =

0 +

Rs3

+ 0

R

d3 =

0

Ris

k d

ue t

o d

irect

stri

kes

to t

he s

tru

ctu

re

Ri3

= 0

+ R

c3 +

0

Ri3

= 0

R

isk

du

e t

o i

nd

irect

stri

kes

to t

he s

tru

ctu

re

R3 =

Ri3

+ R

d3

R3 =

0

To

tal

risk

fo

r a s

tru

ctu

re d

ue t

o l

igh

tnin

g

stri

kes

R

a3 =

1 ×

10

-3

Accep

tab

le r

isk

Co

mp

are

to

tal

risk

to

accep

tab

le r

isk

. If

to

tal

risk

ex

ceed

s accep

tab

le r

isk

, in

cre

ase

th

e l

ev

el

of

pro

tecti

on

measu

res.

RIS

K C

AL

CU

LA

TIO

NS

FO

R D

AM

AG

E C

AT

EG

OR

Y 4

– E

co

no

mic

lo

ss

Rh

4 =

Nd ×

Ph ×

δh

4

Rh

4 =

0

Ris

k o

f d

an

gero

us

step

an

d t

ou

ch

po

ten

tial

to

an

imals

ou

tsid

e t

he s

tru

ctu

re d

ue t

o d

irect

stri

kes

to t

he s

tru

ctu

re

Rs4

= N

d ×

Ps ×

δf4

× k

h4

Rs4

= 2

.48

6 ×

10

-6

Ris

k o

f p

hy

sical

dam

ag

e d

ue t

o d

irect

stri

kes

to t

he s

tru

ctu

re

Rw

4 =

Nd ×

Pw

× δ

o4 ×

kh

4

Rw

4 =

8.2

10

-6

Ris

k d

ue t

o f

ail

ure

or

malf

un

cti

on

of

ele

ctr

ical

an

d e

lectr

on

ic e

qu

ipm

en

t d

ue t

o

ov

erv

olt

ag

es

fro

m d

irect

stri

kes

to t

he

stru

ctu

re

Rm

4 =

Nm

× P

m ×

δo

4 ×

kh

4

Rm

4 =

1.9

38

× 1

0-5

R

isk

of

inte

rnal

eq

uip

men

t fa

ilu

re d

ue t

o a

d

irect

stri

ke t

o g

rou

nd

near

the s

tru

ctu

re t

hat

cau

ses

a d

am

ag

ing

ov

erv

olt

ag

e

Rg

4 =

Pg ×

(N

c1 ×

Pc1 +

Nc2 ×

Pc2 +

Nc1

p ×

Pc1

p +

Nc2

p ×

Pc2

p) ×

δg

4

Rg

4 =

0

Ris

k o

f d

an

gero

us

step

an

d t

ou

ch

po

ten

tial

to

an

imals

ou

tsid

e t

he s

tru

ctu

re d

ue t

o d

irect

stri

kes

to t

he s

tru

ctu

re

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 134: ASNZS 1768-2007

COPYRIGHT

132 AS/NZS 1768:2007

CA

LC

UL

AT

ION

S

Pa

ra

mete

r

Ex

am

ple

va

lue

Rc4 =

kf ×

Pf ×

(N

c1 ×

Pc1 +

Nc2 ×

Pc2 +

Nc1

p ×

Pc1

p +

Nc2

p ×

Pc2

p) ×

δf4

× k

h4

Rc4 =

0

Ris

k o

f fi

re,

ex

plo

sio

n,

mech

an

ical

dam

ag

e

an

d c

hem

ical

rele

ase

cau

sed

by

in

tern

al

eq

uip

men

t fa

ilu

re d

ue t

o a

dir

ect

stri

ke t

o

serv

ice l

ines

that

cau

ses

a d

am

ag

ing

o

verv

olt

ag

e

Re4 =

kw ×

k2 ×

k3 ×

k4 ×

(N

c1 ×

Pc1 +

Nc2 ×

Pc2 +

Nc1

p ×

Pc1

p +

Nc2

p ×

Pc2

p) ×

δo

4 ×

kh

4

Re4 =

0

Ris

k o

f in

tern

al

eq

uip

men

t fa

ilu

re d

ue t

o a

d

irect

stri

ke t

o t

he s

erv

ice l

ines

that

cau

ses

a

dam

ag

ing

ov

erv

olt

ag

e

R1

4 =

(N

11 ×

Pi1

+ N

12 ×

Pi2

+ N

11

p ×

Pi1

p +

N1

2p

× P

i2p) ×

δo

4 ×

kh

4

R1

4 =

1.5

0 ×

10

-6

Ris

k o

f in

tern

al

eq

uip

men

t fa

ilu

re d

ue t

o a

n

ind

irect

stri

ke n

ear

the s

erv

ice l

ines

that

cau

ses

a d

am

ag

ing

ov

erv

olt

ag

e

Rd

4 =

Rh

4 +

Rs4

+ R

w4

Rd

4 =

1.0

70

× 1

0-5

R

isk

du

e t

o d

irect

stri

kes

to t

he s

tru

ctu

re

Ri4

= R

g4

+ R

m4 +

Rc4 +

Re4 +

R1

4

Ri4

= 2

.08

8 ×

10

-5

Ris

k d

ue t

o i

nd

irect

stri

kes

to t

he s

tru

ctu

re

R4 =

Ri4

+ R

d4

R4 =

3.1

58

× 1

0-5

T

ota

l ri

sk f

or

a s

tru

ctu

re d

ue t

o l

igh

tnin

g

stri

kes

R

a4 =

1 ×

10

-3

Accep

tab

le r

isk

Co

mp

are

to

tal

risk

to

accep

tab

le r

isk

. If

to

tal

risk

ex

ceed

s accep

tab

le r

isk

, in

cre

ase

th

e l

ev

el

of

pro

tecti

on

measu

res.

Rd =

Rd

1 +

Rd

2 +

Rd

3 +

Rd

4

Rd =

1.5

51

× 1

0-5

Ri =

Ri1

+ R

i2 +

Ri3

+ R

i4

Ri =

2.0

88

× 1

0-5

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 135: ASNZS 1768-2007

133 AS/NZS 1768:2007

COPYRIGHT

APPENDIX B

THE NATURE OF LIGHTNING AND THE PRINCIPLES OF LIGHTNING

PROTECTION

(Informative)

B1 SCOPE OF APPENDIX

This Appendix deals with the nature of the phenomena involved in a study of lightning

protection and the basic principles of designing such protection. A brief description of

various elements of an LPS and their function is also provided.

Recommendations for systems to protect against the direct or indirect effect of lightning are

given in the body of this Standard.

B2 THE NATURE OF LIGHTNING

B2.1 Nature of lightning

Thunderstorms occur under particular meteorological conditions, and partial separation of

electrical charges within the thundercloud usually results in regions with net negative

charge mainly in the lower parts of the thundercloud, and regions with net positive charge

mainly in the upper part. Lightning is an electrical discharge between differently charged

regions within the cloud (cloud flash) or between a charged region, nearly always the lower

negatively charged region, and earth (ground flash).

A complete ground flash consists of a sequence of one or more high amplitude short

duration current impulses, or strokes. Significant numbers (about 40%) of ground flashes

have more than one ground termination, usually separated by distances up to a few

kilometres (Paragraph G2, Ref. 8). In some ground flashes low amplitude long duration

currents (sometimes termed continuing currents) flow between the strokes or after a

sequence of strokes. The currents are unidirectional and usually negative, i.e. a negative

charge is injected into the object struck. For all practical purposes the stroke can be

considered to be generated by a current source whose waveshape and magnitude are

unaffected by the characteristics of the ground termination.

B2.2 The lightning attachment process

The first stroke of a ground flash is normally preceded by a downward-progressing

low-current leader discharge that commences in the negatively charged region of the cloud

and progresses towards the earth, depositing negative charges in the air surrounding the

leader discharge channel. When the lower end of the leader is roughly 100 m from the earth,

electrical discharges (streamers) are likely to be initiated at protruding earthed objects, and

to propagate upwards towards the leader discharge channel. Several streamers may start, but

usually only one is successful in reaching the downcoming leader. The high current phase

(return stroke) commences at the moment the upward moving streamer meets the

downcoming leader. The position in space of the lower portion of the lightning discharge

channel is therefore determined by the path of the successful streamer, i.e. the one that

succeeded in reaching the downcoming leader. The primary task in protecting a structure is

therefore to ensure a high probability that the successful streamer originates from the

lightning protection conductors, and not from a part of the structure that would be adversely

affected by the lightning current that subsequently flows.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 136: ASNZS 1768-2007

AS/NZS 1768:2007 134

COPYRIGHT

As the path of the successful streamer may have a large horizontal component, e.g. many

tens of metres, as well as a vertical component, an elevated earthed conductor will provide

protection for objects spread out below it. It is therefore possible to provide protection for a

large volume with a relatively small number of correctly positioned conductors. This is the

basis for the concept of a zone of protection provided by an elevated earthed conductor, and

provides the basic principle underlying interception lightning protection. Thus the basic

protection system consists of air terminals to provide launching points for streamers, and

downconductors and earthing electrodes to deliver the lightning current into the earth.

B2.3 Thunderstorm and lightning occurrence

Thunderstorm occurrence at a particular location is usually expressed in terms of the

number of calendar days in a year when thunder was heard at the location, averaged over

several years. The resulting information is usually given as an average annual thunderday

map. The frequency of occurrence of thunderstorms varies significantly depending on

location. Moreover, the severity of lightning storms, as distinct from their frequency of

occurrence, is known to be much greater in some areas than in others. Hence, the need for

protection varies across the country, although not necessarily in direct proportion to

thunderstorm frequency. A few severe thunderstorms in a season may make the need for

protection greater than a relatively large number of storms of lesser activity. Therefore,

lightning ground flash density is a better measure of lightning activity in a particular

location.

Data on the geographical distributions of average ground flash density are given in

Section 2—

(a) in Figure 2.3 for Australia; and

(b) in Figure 2.4 for New Zealand.

Earlier editions of AS/NZS 1768 provided Thunderday maps, and ground flash density (Ng)

could be estimated from thunderdays (Td) using an equation of the form—

Ng = a Tdb . . .B2.3

in which a and b are empirically determined constants, with values of a = 0.012 and b = 1.4

appropriate for Australia (Paragraph G2, Ref. 9); the so called CIGRE formula adopted by

IEC has a = 0.04 and b = 1.25, and generally gives higher values for Ng.

Local topographical features may cause variations in the occurrence of ground flashes. The

occurrence will be higher than the average on high ground, e.g. ridges, and lower than

average on nearby low ground. In some cases, a large topographical feature such as a high

mountain may interact with prevailing meteorological conditions to cause a concentration

of thunderstorms and ground flashes. Such effects may be identified by enquiry of local

telecommunications and electricity supply engineers or meteorological stations, and of local

residents. On a smaller scale, tall objects, e.g. roof of a building, tree top or overhead

conductor, tend to divert lightning flashes to themselves, as explained in Paragraph B2.2,

thus shielding a certain surrounding area from direct strikes.

There is a network of lightning flash counters (LFC) in Australia. The available count data

enable estimates to be made of ground flash density at the LFC sites, but these require

corrections for site and calibration errors and for response to nearby cloud flashes. Recently

lightning positioning systems have been installed in Australia and New Zealand and data

are available from the commercial providers. Earlier systems have been in operation in

central-east New South Wales and south-east Queensland for about twenty years, but their

data are not extensive and may not be reliable. Optical observations of lightning flashes

are made from satellites fitted with appropriate sensors. Considerable data on worldwide

lightning activity are now available from U.S. satellites which usually survey the earth from

near-polar orbits. Worldwide data and maps since April 1995 of recorded lightning flashes

are readily accessible on a NASA website (Paragraph G2, Ref. 10).

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 137: ASNZS 1768-2007

135 AS/NZS 1768:2007

COPYRIGHT

In Australia, the geographical distribution of lightning incidence is described by a map of

average annual lightning ground flash density, Ng (Paragraph G2, Ref. 11). The map has

been derived using lightning data obtained by ground-based lightning detection instruments

such as CIGRE-500 and CGR3 and by NASA satellite-based instruments such as Optical

Transient Detector and Lighting Imaging Sensor. This map is contoured in units of flash

density (km−2

yr−1

). Ng varies from over 6 km−2

yr−1

in the northern parts of Australia to

about 1 km−2

yr−1

and below in the southern parts. The map is recommended for estimating

Ng values for lightning protection system design. The overall uncertainty in the flash

density values indicated on the Australian flash density map is estimated to be ±30%.

The New Zealand Ng map has been derived from ground flash density data obtained from

the Lightning Detection Network of New Zealand for the period 1 January 2001 through to

9 February 2006.

B3 EFFECTS OF LIGHTNING

The principal effects of a lightning discharge to an object are electrical, thermal and

mechanical. These effects are determined by the magnitude and waveshape of the current

discharged into the object and the nature of the object itself. Statistical distributions of

some characteristics of ground flashes are given in Table B1.

When the lightning current flows through the building or LPS, the electrical potential of the

building may rise to a high, usually negative, value with respect to remote earth.

The lightning current produces a high potential gradient around the earthing electrode that

can be dangerous to persons and to livestock.

The rate of rise of current in conjunction with inductance of the discharge path produces a

voltage drop that will vary in time depending upon the current waveshape; because of the

fast rate of rise of the lightning discharge current, the inductance of conductors assumes a

far greater importance in determining potential rise than does the resistance of conductors.

The voltage across an inductor is given by the expression V = L × di/dt. Assuming an

approximate inductance of 1μH/m for a typical conductor and a typical rate of rise of

current of 25 kA/μs, the voltage developed across a 40 m length of 25 × 3 mm copper strap

is 1 MV, compared to just 770 V due to its resistance. As the point of strike on the LPS may

be raised to a high potential, there is also the risk of a flashover from the LPS to nearby

objects. This is called a side-flash. The risk of side-flash is increased at any deeply

re-entrant bend or loop in a downconductor due to the local increase in inductance. If such a

flashover occurred, part of the lightning current would be discharged through internal

installations with consequent risk to the occupants and the fabric of the building.

The amount of energy deposited in any object carrying lightning current may be calculated

by multiplying the action integral by the electrical resistance of the object. From this, the

temperature rise may be calculated. It should be noted however, that the resistance of most

objects other than metallic conductors, e.g. wood, masonry or earth, is very non-linear for

the large currents associated with lightning. It should also be noted that the passage of

lightning current through moist resistive materials such as masonry or wood can convert the

moisture to high-pressure steam, causing the material to explode or shatter.

The thermal effect of a lightning discharge is confined to the temperature rise of the

conductor through which the lightning current is discharged. Although the amplitude of a

lightning current may be high, its duration is so short that the thermal effect on an LPS, or

on the metallic parts of a structure where this is included in the LPS, is usually negligible.

This ignores the fusing or welding effects that occur locally consequent upon the rupture of

a conductor that was previously damaged or was of inadequate cross-section. In practice the

cross-sectional area of a normal lightning conductor is determined primarily by mechanical

and secondarily by thermal considerations.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 138: ASNZS 1768-2007

AS/NZS 1768:2007 136

COPYRIGHT

At the point of attachment of a lightning discharge channel to a thin metal surface, a hole

may be melted in the surface. In the rare case where this occurs, some thermal energy will

be deposited directly in the metal from the hot plasma of the lightning discharge channel, as

well as the thermal energy caused by the passage of current through the metal. The size of

the hole melted in the sheet depends on the material, the thickness of the sheet, and the

charge delivered. For example, a moderately severe lightning flash delivering a charge of

70 C would melt a hole about 12 mm in diameter in a sheet of roofing iron.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 139: ASNZS 1768-2007

137 AS/NZS 1768:2007

COPYRIGHT

TABLE B1

SUMMARY OF THE FREQUENCY DISTRIBUTIONS OF THE MAIN

CHARACTERISTICS OF THE LIGHTNING FLASH TO GROUND

Percentage of events having value of characteristic

greater than value shown below (see Note 1) Item

No Lightning characteristic

99 90 75 50 25 10 1

Unit

1 Number of common strokes 1 1 2 3 5 7 12 —

2 Time interval between

strokes 10 25 35 55 90 150 400 ms

3 First stroke peak current

Imax. 5 12 20 30 50 80 130 kA

4 Subsequent stroke peak

current Imax. 3 6 10 15 20 30 40 kA

5 First stroke (di/dt)max. 6 10 15 25 30 40 70 kA/μs

6 Subsequent stroke (di/dt)max. 6 15 25 45 80 100 200 kA/μs

7 Total charge 1 3 6 15 40 70 200 C

8 Continuing current charge 6 10 20 30 40 70 100 C

9 Continuing current Imax. 30 50 80 100 150 200 400 A

10 Overall duration of flash 50 100 250 400 600 900 1 500 ms

11 Action integral (see Note 2) 102 3 × 102 103 5 × 103 3 × 104 105 5 × 105 A2.s

NOTES:

1 The values shown in this table have been derived from a number of sources, and have been rounded in

accordance with the accuracy with which these data are known. Values at the 1 percent and 99 percent

levels are very uncertain, and are given only to indicate an order of magnitude.

2 The action integral, defined as ti d2∫ for the whole flash, is equivalent to the energy deposited in a one-

ohm resistor by the passage of the entire current for the duration of the flash.

The passage of lightning current through a conductor causes a force on the conductor given

by the equation:

F = B × l × i . . . B3

where

F = the force on the conductor, in newtons (N)

B = the component of the magnetic flux density at right angles to the conductor, in

teslas (T)

l = the length of the conductor, in metres (m)

i = the current through the conductor, in amperes (A)

B4 POTENTIAL DIFFERENCES CAUSED BY LIGHTNING

B4.1 General

A lightning flash to a building or structure, or a flash to ground near a building or structure

will cause a potential rise in the vicinity of the strike attachment point, and may also cause

a potential rise of objects remote from the point of strike. For example, a lightning strike to

a service conductor (electricity supply, telecommunications, or other metallic service) can

cause current to be transmitted to the building, thus raising the potential of the building. A

lightning flash to ground can also induce voltages and currents in remote conductors by

electric and magnetic coupling (see also Section 5 and Appendix F). Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 140: ASNZS 1768-2007

AS/NZS 1768:2007 138

COPYRIGHT

B4.2 Earth currents

At the point where the lightning current enters the ground the current density is high.

Hazardous earth potential gradients may be generated. Earthing electrodes should be

distributed more or less symmetrically, preferably outside and around the circumference of

a structure, rather than be grouped on one side. This will help to minimize earth potential

gradients near the building, and tend to cause the lightning current to flow away from the

building rather than underneath it.

In addition, with earth connections properly distributed, the current from a lightning flash

to ground near the building will be concentrated at the outer extremities. Thus current flow

underneath the building, as well as earth potential gradients, will be minimized.

B4.3 Side-flash

If a lightning conductor system is placed on a building and there are unbonded metal

objects of considerable size nearby, there will be a tendency for side-flashing to occur

between the conductors of the LPS and the unbonded metal objects. To prevent damage

from side-flash, interconnecting conductors should be provided at all places where side-

flashes are likely to occur. This is referred to as equipotential bonding, although complete

equalization of potential is never achieved. As the currents required to equalize potentials

are considerably less than the full lightning current, conductors of relatively small

cross-section are adequate for this purpose (see also Clause 4.16.2).

B4.4 Potential (voltage) differences

The impedance of the earth termination network to the rapidly changing lightning current

influences the potential rise of the LPS. This in turn affects the risk both of side-flashing

within the structure to be protected, and of dangerous potential gradients in the ground

adjacent to the earth termination network. The potential gradient around the earth

termination network, on the other hand, depends on the physical arrangement of the

earthing electrodes and the soil resistivity. In Figure B1, a lightning flash is assumed to

occur to the LPS of a building. For the purposes of the illustration, no equipotential bonding

is shown although such bonding is required in accordance with this Standard. As the

lightning current is discharged through the downconductor and the earthing electrode, the

conductor system and the surrounding soil are raised, for the duration of the discharge, to a

potential with respect to the general mass of the earth. The resulting potential differences as

shown by ‘step’, ‘touch’ and ‘transferred’ potentials in Figure B1 may be lethal; hence the

importance of keeping the impedance of the earth termination network low, and of

preventing large local potential gradients by equipotential bonding, and by the manner in

which the earthing electrodes are arranged.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 141: ASNZS 1768-2007

139 AS/NZS 1768:2007

COPYRIGHT

NOTES:

1 Person X is in contact with the ground at a and b: person Y is in contact with the ground at c and the

conductor at d; person Z is in contact with the conductor at e and a metallic handrail f shown earthed at g.

2 Person X is subject to ‘step’ potential.

3 Person Y is subject to ‘touch’ potential.

4 Person Z is subject to ‘transferred’ potential.

5 The potential depends on the current magnitude and the impedance of the path of the lightning discharge.

6 Step potential increases with the size of the step a-b in the radial direction from the conductor and

decreases with the increase in the distance between person X and the conductor.

7 The transferred potential increases with increase in the radial distance between the downconductor and the

ground at g.

8 The diagram does not show equipotential bonding that may be necessary to protect persons from hazardous

potential differences of the type described in this diagram (see Sections 4 and 5).

FIGURE B1 INSTANTANEOUS POTENTIAL DIFFERENCES DURING A LIGHTNING

FLASH TO AN EARTHED CONDUCTOR

B5 PRINCIPLES OF LIGHTNING PROTECTION

B5.1 Purpose of protection

The purpose of lightning protection is to protect persons, buildings and their contents, or

structures in general, from the effects of lightning, there being no evidence for believing

that any form of protection can prevent lightning strikes.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 142: ASNZS 1768-2007

AS/NZS 1768:2007 140

COPYRIGHT

B5.2 Interception of lightning

The function of an air terminal in an LPS is to divert to itself the lightning discharge that

might otherwise strike a vulnerable part of the object to be protected. It is generally

accepted that the range over which an air terminal can attract a lightning discharge is not

constant, but increases with the severity of the discharge.

The path of a lightning discharge near a structure is determined by the path of the

successful streamer (see Paragraph B2.2) that will usually be initiated from a conducting

part of the structure nearest to the downcoming leader. The initiation of streamers is also

influenced by the local electric field. The upper outer edges and corners of buildings or

structures, and especially protruding parts, are likely to have higher local electric fields

than elsewhere, and are therefore likely places for the initiation of streamers. When the

downcoming leader is within about 200 m of the building, the electric field at these

protruding parts and corners will exceed the breakdown field strength of air, resulting in

corona currents that cause these parts to be surrounded by ionized air. The resulting space

charges influence the electric field in such a manner that the field is limited to the

breakdown strength of air. However, these complicating factors do not alter the fact that the

most probable strike attachment point on a building is the edge, corner, or other protruding

part closest to the downcoming leader. This is the basic reason why the RSM gives a

reliable guide to the most probable strike attachment points.

Hence, if air terminals are placed at all locations where high electric fields and streamer

initiation are likely, there will be a high probability that the discharge will terminate on

some portion of the LPS.

B5.3 Determination of lightning strike attachment points to buildings

B5.3.1 The rolling sphere method

The procedure for determining lightning strike attachment points is based on the RSM

whereby a sphere of specified radius is imagined to be rolled across the ground towards the

building, up the side, and over the top of the building, and down the other side to ground.

This can be carried out in various orientations with respect to the building. Any point on the

building touched by the sphere is a possible lightning strike attachment point.

The physical basis for this method is as follows. As the lightning leader stroke approaches

the ground, the electric field at various salient points, such as the upper corners of

buildings, will help to launch electrical discharges, or streamers, that progress upwards

toward the tip of the downcoming leader stroke. The position in space of the lightning

discharge channel, and the location of the strike attachment point, is determined when the

leader and one of the upward streamers join to complete the lightning discharge path. The

upward streamer that determines the strike attachment point is generally that launched from

the salient point or earthed conductor closest to the downcoming leader. The rolling sphere

will tend to touch those salient points, and the method therefore provides a geometric means

of identifying such points.

B5.3.2 The striking distance

The striking distance, ds, is the distance between the leader tip and the eventual strike

attachment point at the moment when it has become inevitable that the gap, of dimension ds,

will be bridged by the lightning discharge channel.

The RSM is closely related to the electrogeometric method developed for predicting

lightning attachment to electricity supply service lines, whereby the lightning leader is

supposed to progress until it comes within the distance ds of an earthed object, when the

final discharge path is determined to that object.

There are theoretical and observational grounds for a relationship between ds and the imax.,

where imax. is the peak return stroke current. The following relationship has been proposed: Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 143: ASNZS 1768-2007

141 AS/NZS 1768:2007

COPYRIGHT

ds = 10 × imax.0.65 . . . B5.3.2

where

ds = the striking distance, in metres (m)

imax. = the peak current of the return stroke, in kiloamperes (kA)

The advantage of the RSM is that it is relatively easy to apply, even to buildings of

complicated shape. The limitation of the method is that no account is taken of the influence

of electric fields in initiating return streamers, and the method therefore does not

distinguish between likely and unlikely lightning strike attachment points. In particular, the

enhancement of electric fields at the upper outer corners of a building makes these corners

the most probable strike attachment points, whereas return streamers are unlikely to be

initiated from a flat surface away from a corner or edge, even if on the roof and touched by

the sphere. Therefore, in Clause 4.4.2, an increased radius of the rolling sphere was

introduced for dealing with the protection of plane surfaces.

Some qualitative indication of the probability of strike attachment to any particular point

can be obtained if the sphere is supposed to be rolled over the building in such a manner

that its centre moves at constant speed. Then the length of time that the sphere dwells on

any point of the building gives a qualitative indication of the probability of that point being

struck. Thus for a simple rectangular building with a flat roof, the dwell time would be

large at the corners and edges, and small at any point on the flat part of the roof, correctly

indicating a high probability of the corners or edges being struck, and a low probability that

a point on the flat part of the roof will be struck.

The RSM with its modification of an increased radius for plane surfaces is now applied

with some account of electric field enhancement effects in mind, so that high priority is

given to providing air terminals at the more probable attachment points. For a building of

more or less rectangular shape with a flat roof, this means giving top priority to providing

air terminals around the periphery of the roof. This could take the form, for example, of a

metallic perimeter handrail.

B5.4 Protection of the sides of tall buildings

When the RSM is applied to a building of height greater than the selected sphere radius,

then the sphere touches the vertical edges on the sides of the building at all points above a

height equal to the sphere radius and a sphere of the corresponding increased sphere radius

touches all flat surfaces on the sides about a height equal to the increased radius. This

indicates the possibility of strikes to the sides of the building, and raises the question of the

need for an air terminal network on the sides of the building.

Practical experience indicates that strikes to vertical edges on the sides of tall buildings do

occur but are uncommon in that strikes rarely occur to the flat side surfaces. There are

theoretical reasons for believing that only flashes with low imax. and consequently low ds

values are likely to be able to penetrate below the level of the roof of the building and strike

the sides. The consequences of a strike to the sides of a building may result in damage of a

minor nature. Unless there are specific reasons for side protection, as would be the case for

a structure containing explosives, it is considered that the cost of side protection would not

normally be justified.

If it is decided that some protection for the sides of a building is justified, then conductors

should be provided at the most probable lightning attachment points on the sides of the

building. The most probable attachment points are at protruding corners and vertical edges

of the sides of the building, including surfaces with changes greater than 20°. The

conductors will generally serve both as air terminals and downconductors and will in

general be connected to the roof air terminal network at their upper ends, and to the

earthing termination network at their lower ends. The conductors may be made flush with

the surface, and should be placed as near as practicable to the vertical edge to be protected. Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 144: ASNZS 1768-2007

AS/NZS 1768:2007 142

COPYRIGHT

Where the building construction includes extensive metal objects on the vertical outer

surfaces, such as large metallic window frames, then such objects can form part of the

interception protection system. It is necessary to provide electrical connections between

adjacent metal objects both in the horizontal and vertical directions, and to provide periodic

connections between the surface metalwork and the reinforcing steel, or the

downconductors if separate from the reinforcing. This provides multiple paths for the

lightning current from any point on the surface metalwork to earth, and local potential

differences will be reduced to an acceptable level.

Return streamers are more likely to develop from a good conductor on the surface than from

a poor conductor in a similar position. Thus if a wall consists mainly of a poorly conducting

material, and there are isolated objects with earth connections made of a highly conductive

material distributed over the surface, then the return streamers will tend to originate

preferentially from the highly conducting objects with earth connections. A wall of poorly

conducting material can therefore be substantially protected by earthed metallic studs

placed on a grid pattern flush with the surface of the wall. Alternatively, protection can be

provided by a system of metallic strips flush with the surface. Even if the lightning happens

to strike a point on the non-conducting surface away from an earthed conducting point, it is

likely that it will track across the non-conducting surface and terminate on the earthed

conducting point.

B5.5 Safe discharge to earth

B5.5.1 General

If the air terminal network is adequately connected to earth, the current will pass to ground

without damage to the structure. Metallic parts of a building or structure may usefully be

made part of the LPS, provided that the passage of lightning current will not cause harm

(for bonding of metal in or on a structure, see Clause 4.16.2.2).

B5.5.2 Use of reinforcing steel as a downconductor

It is sometimes suggested that overlapped and tied reinforcing rods do not provide good

electrical connections, and are therefore not suitable for carrying lightning currents.

However, the situation differs greatly from that in which a conducting path for power

currents is required. Even if there are thin films of iron oxides and cement between the bars,

the voltage required to cause breakdown of these films would be less than 1000 V. Once

breakdown has occurred, there would be localized arcing between the steel bars, with a

voltage drop of a few tens of volts. The initial breakdown across the oxide and cement films

would occur during the first few microseconds of the first stroke when there is a large

inductive voltage drop from top to bottom of the building; this voltage would be very much

larger than the voltage required to break down the oxide and cement films between bars.

Thus there are good reasons for relying on the reinforcing bars to act as downconductors,

even when no special precautions have been taken (such as welding the bars together) to

ensure electrical continuity. The localized arcing referred to above would produce relatively

small amounts of energy in relation to the thermal capacity of typical reinforcing bars, so

heating effects should be negligible.

Where the structural steel reinforcement of the building is to be utilized as the

downconductor system, it is important that there be an effective electrical connection

between the air terminal network and the steel reinforcement. Such connections should be

made as close as practicable to the top of the building and preferably at a number of points

around the building perimeter.

Tall metal structures, such as chimneys, provide an adequate conducting path, but care must

be taken to ensure that they are also suitably earthed.

Special precautions are needed for the protection of structures containing explosives,

highly-flammable materials and gases. The principles involved in such protection systems

are given in Section 7.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 145: ASNZS 1768-2007

143 AS/NZS 1768:2007

COPYRIGHT

B5.6 Potential equalization

As explained in Paragraph B4, lightning strikes may give rise to harmful potential

differences within a building. Of particular concern is the occurrence of potential

differences that may exist between local earth and incoming conductors such as metallic

water services, telecommunication systems, and electricity supply systems.

Reduction of these potential differences may be achieved by a system of coordinated

bonding of all affected conductors contained in the building. This includes all incoming

metallic services, protective earths associated with electricity supply and

telecommunications systems, and the building lightning protection earth termination

network (if provided). Potential equalization (understood to imply approximate potential

equalization) may be effected by including in the bonding scheme earthed building

metalwork such as reinforcement metals and metal framework, if any. In cases where the

presence of dissimilar metals may create corrosion problems or for other reasons, the

commoning path may be effected by using suitably rated SPDs.

B6 ELEMENTS OF A PROTECTION SYSTEM

The main parts of a typical LPS for a building or structure may be summarized as follows,

noting that not all parts will be present in all systems:

(a) Air terminals are placed so as to achieve interception lightning protection, ensuring a

high probability that lightning will attach to the air terminal network, and not to parts

of the protected object that could be damaged by lightning current. Existing

metalwork should be used as far as possible, supplemented by carefully positioned air

terminals giving priority to high probability attachment points. These are the upper

outer corners and edges of the building and any salient or protruding objects on the

roof. The form of air terminal should be chosen for simplicity and low cost consistent

with adequate mechanical strength, durability and aesthetic acceptability.

(b) Downconductors are used to convey lightning current towards the earth. Existing

building metalwork should be used as far as possible, especially steel frames and

reinforcing steel in reinforced concrete columns, supplemented where necessary by

external downconductors. If these downconductors are also to serve as part of the air

terminal network for the sides of a tall building, they should preferably follow the

outer vertical corners of the building. Where the number of downconductors required

exceeds the number of vertical corners, the remaining downconductors should be

placed uniformly between the ones at the corners.

(c) Test links may be required between the downconductors and the earthing electrodes

to facilitate the testing of the LPS.

(d) The earth termination network consisting of one or more earthing electrodes, and any

interconnecting conductors between earthing electrodes, serves the purpose of

delivering the lightning current into the general mass of the earth. The footings of

large reinforced concrete buildings will generally provide a better earth connection

than can be provided by driven earthing electrodes around the periphery. Where the

superficial layers of the earth have high resistivity, deep driven earthing electrodes

may be needed to reach low-resistivity regions, and achieve an acceptable earth

resistance.

(e) Equipotential bonding is used to reduce or prevent hazardous potential differences

between any pair of extended conducting objects in the building or structure.

Equipotential bonding becomes particularly important in buildings or structures

having a high earth resistance. In the extreme situation where an acceptable

connection to earth cannot be achieved, it would be necessary to rely entirely on

equipotential bonding to protect persons and equipment against hazardous potential

differences caused by lightning. Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 146: ASNZS 1768-2007

AS/NZS 1768:2007 144

COPYRIGHT

(f) Equipotential bonding may, in some situations, be achieved by means of SPDs, where

direct connection of the conducting parts results in an unwanted effect, for example,

corrosion of metals, degradation or loss of communications.

(g) Overvoltage protection is achieved by using various types of SPDs (e.g. spark gaps,

gas-filled surge arrestors or MOVs) to prevent hazardous potential differences being

applied to persons or equipment, while allowing correct operating potentials to exist

(see Section 5 and Appendix F).

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 147: ASNZS 1768-2007

145 AS/NZS 1768:2007

COPYRIGHT

APPENDIX C

NOTES ON EARTHING ELECTRODES AND MEASUREMENT OF EARTH

IMPEDANCE

(Informative)

C1 GENERAL

C1.1 Function of an earthing electrode

The function of an earthing electrode is to provide an electrical connection to the general

mass of earth. The characteristic primarily determining the effectiveness of an earthing

electrode or group of interconnected earthing electrodes (earth termination network) is the

impedance that it provides between the earth termination network and the general mass of

earth.

C1.2 Factors influencing earth impedance

The impedance of the earth termination network to lightning currents varies with time and

the magnitude of the current, and is dependent on—

(a) the resistance and surge impedance of the earthing electrode and the connecting

conductors;

(b) the contact resistance between the earthing electrode and the surrounding soil;

(c) the resistivity of the soil surrounding the earthing electrode; and

(d) the degree of soil ionization.

The resistance of the metallic conductors in the earth termination network can generally be

neglected.

In addition there are often fortuitous paths to earth, e.g. via bonded electricity reticulation

low-voltage neutrals. These can mask the earthing electrode impedance by paralleling other

routes of high surge impedance but low d.c. or low-frequency impedance to earth. It is

essential to utilize measurement techniques, referred to later, to discriminate between these

conditions.

C1.3 Measures for reducing earth impedance

Lightning current is considered to be a high frequency phenomenon with current rise times

in the order of 10 kiloamperes per microsecond (10 kA/μs). In these circumstances, an earth

termination network can best be regarded as a ‘leaky’ transmission line. Each conductor has

resistance, inductance and capacitance to earth and leakage through non-insulated contact.

An examination of earthing conductors using transmission line equations will show that the

impedance of the earth termination network is lowered by the following:

(a) The use of flat strip rather than circular conductors. This increases surface area,

reduces high-frequency resistance due to skin effect, increases both capacitive

coupling and the earth contact area for a given cross-section of conductor.

(b) The use of a centre point feed to create the effect of two parallel connected

transmission lines is also effective. This concept can be further enhanced by using

several radial conductors emanating from the injection point.

(c) The use of short-length multiple conductors for example up to 30 m, is preferred over

long buried systems.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 148: ASNZS 1768-2007

AS/NZS 1768:2007 146

COPYRIGHT

(d) The use of ground enhancing compound around the conductor can reduce the

impedance of the earth electrode (see Paragraph G2, Ref. 12). The reduction in

impedance is achieved by greatly increasing the effective surface area and capacitive

coupling of the conductor to the soil.

In areas of low to moderate soil resistivity, vertical earthing electrodes will, for an earthing

electrode of given dimensions, usually be more effective in providing a low surge

impedance.

When trench (horizontal) earthing electrodes are installed, the initial surge impedance of

two or more electrically paralleled wires or strips, radiating symmetrically from a central

connection point, will be less than the equivalent length laid as one single unit. However,

the multiped earthing electrode will be of higher d.c. or low-frequency resistance due to

electric field interaction between the individual earthing electrode segments near the central

connection point. The optimum surge performance for a single horizontal earthing electrode

will usually be achieved when the downconductor attaches to its midpoint.

The contact resistance between the earthing electrode and the soil can be up to about 10

percent of the total resistance of the earth termination network. This resistance may be

reduced by ionization and arc-over in the soil in contact with the earthing electrode. The

major part of the earth resistance of an earthing electrode arises from the resistance of the

earth in the immediate vicinity of the earthing electrode. The value of this resistance

depends upon the shape, size, and position of the earthing electrode and the resistivity,

moisture content and degree of ionization of the soil in the vicinity of the earthing

electrode. The ratio of resistance at peak impulse current to resistance at low current

depends on the number and arrangement of the electrodes, the peak current and soil

resistivity. Examples are given in Table C1.

C2 RESISTIVITY OF SOIL

C2.1 General

Soil resistivity is another term for the specific resistance of soil. It is usually expressed in

ohm metres (symbol Ω.m), i.e. the resistance in ohms between opposite faces of a cube of

soil having sides 1 m long.

The resistivity of the soil depends on its chemical and mechanical composition, moisture

content and temperature. In view of this there is a very large variation in resistivity between

different types of soils and with different moisture contents. This is illustrated in Tables C2,

C3 and C4.

NOTE: Earthing electrodes should not be located near brick kilns or other installations where the

soil can be dried out by the operating temperatures involved.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 149: ASNZS 1768-2007

147 AS/NZS 1768:2007

COPYRIGHT

TABLE C1

EXAMPLES OF REDUCTION OF RESISTANCE OF EARTH CONNECTION

UNDER IMPULSE CONDITIONS

Soil resistance characteristic No. of rods and arrangement

One isolated rod Four rods at corners of square,

3.05 m sides

Soil resistivity, Ω.m 102 103 102 103

Resistance at low currents, Ω 30 300 10.5 105

Resistance at current peak, Ω 11.3 54 6.8 37

Ratio of resistance at current

peak/resistance at low current 0.38 0.18 0.65 0.35

NOTE: The table depends on the following earthing dimensions and conditions:

Diameter of rods = 10 mm Depth in earth = 3.05 m

Peak current injected = 80 kA Time to current crest = 4 μs

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 150: ASNZS 1768-2007

AS/NZS 1768:2007 148

COPYRIGHT

TABLE C2

RESISTIVITY VALUES FOR VARIOUS MATERIALS

Material Resistivity, Ω.m

Typical Usual limits

Salt sea water 0.2 0.15 to 0.25

Estuarine water 0.5 0.2 to 5

Artesian water 4 2 to 12

Damp black inland soil (see Note 1) 8 5 to 100

Damp clay 10 2 to 12

Inland lake water, reservoirs 20 10 to 500

River banks, alluvium 25 10 to 100

Clay/sand mixture (see Note 2) 30 20 to 200

River water (upstream) 40 30 to 200

Concrete (see Note 3) 100 40 to 1000

Dry inland soil (see Note 1) 100 20 to 1000

Moraine gravel 2000 1000 to 10000

Coal 2000 1000 to 5000

Secondary rock 3000 1000 to 50000

Sand (see Note 2) 3000 1000 to 10000

Solid volcanic rock (see Note 4) 20000 10000 to 50000

Ice (see Note 5) 100000 10000 to 100000

NOTES:

1 ‘Black soil’ is a non-specific term applicable to vast areas of Queensland and New South Wales. The soil

is characterized by a high level of dissolved salts, and undergoes considerable contraction on drying out,

thus causing a significant increase in volume resistivity when dry.

2 Resistivity values for a clay/sand mixture and for sand are based on measurements of a number of sites in

Queensland. The resistivity of dry sand is intrinsically very high and it will serve to increase the

resistivity of any material in which it may be interspersed.

3 Values of resistivity for concrete apply to the cast material and do not include the effect of any

reinforcing bars. The values given will assist in determining the discharge resistance from steel

reinforcement to the general body of earth.

4 Solid volcanic rock is often subject to fissures and faults the contents of which substantially reduce the

resistivity, though not to a very satisfactory level for earthing electrode performance for lightning

protection.

5 Ice is included for reference. It is not anticipated that ice will be of significance in design for the normal

range of conditions.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 151: ASNZS 1768-2007

149 AS/NZS 1768:2007

COPYRIGHT

TABLE C3

VARIATION OF SOIL RESISTIVITY WITH MOISTURE CONTENT

Moisture content

(percent by weight)

Typical value of resistivity

Ω.m

Clay mixed with sand Sand

0 10000000 —

2.5 1500 3000000

5 430 50000

10 185 2100

15 105 630

20 63 290

30 42 —

TABLE C4

VARIATION OF RESISTIVITY WITH

TEMPERATURE IN A MIXTURE OF SAND

AND CLAY WITH A MOISTURE CONTENT

OF ABOUT 15 PERCENT BY WEIGHT

Temperature Typical value of resistivity

°C Ω.m

20

10

0 (water)

72

99

138

0 (ice)

−5

−15

300

790

3300

C2.2 Artificial reduction of soil resistivity

Chemical additives can be used to reduce soil resistivity. These additives generally take the

form of fully ionizable salts such as sulphates, chlorides or nitrates. Such chemical

additives should not be used indiscriminately as—

(a) the benefit that they provide will lessen with time due to leaching through the soil;

and

(b) they may increase the rate of corrosion of the earthing electrode material.

Some of the chemical additives are also objectionable from an environmental viewpoint.

A bland backfill material such as calcium or sodium bentonite clay, or montmorillonite with

finely ground gypsum will reduce resistivity for a considerable period in high resistivity

soils, maintain some moisture adjacent to the earth termination network, and provide a

uniform and non-corrosive environment for the earthing electrodes. For further information

see the recommendations in AS 2239 relating to the backfilling of galvanic anodes.

C2.3 Determining soil resistivity by test

It is fairly easy and useful to determine soil resistivity by test before commencing to install

earthing electrodes. Testing procedures are given in Paragraph C10.1.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 152: ASNZS 1768-2007

AS/NZS 1768:2007 150

COPYRIGHT

C3 CALCULATION OF EARTH RESISTANCE OF AN EARTHING ELECTRODE

If the soil resistivity is known (see Paragraph C2.3), the earth resistance R in ohms can be

calculated as follows:

(a) Single vertical rod of length L and diameter d metres, top of rod level with surface:

R = 8

ln 1 2

ρ L

L d

⎡ ⎤⎛ ⎞−⎜ ⎟⎢ ⎥π ⎝ ⎠⎣ ⎦

. . . C3(1)

where

R = resistance, in ohms

ρ = soil resistivity, in ohm metres

L = buried length of earthing electrode, in metres

d = diameter of earthing electrode, in metres

NOTE: Equation C3(1) is commonly referred to as the ‘modified Dwight formula’.

(b) As above, but top of rod h metres below surface:

R = L + h

L + h

d

L

L 4

2 1

8 ln

2⎥⎦

⎤⎢⎣

⎡−⎟

⎞⎜⎝

π

ρ . . . C3(2)

(c) Thin circular plate, diameter D metres, on surface:

R = D2

ρ . . . C3(3)

(d) Thin circular plate, diameter D metres, buried h metres below surface:

R = ⎟⎠

⎞⎜⎝

h

D

D π

ρ

4 + 0.5

2 . . . C3(4)

For a vertical plate, h is measured from the centre of the plate. In the case of a square

plate, the diameter can be replaced with 1.13 times the side of the square.

(e) Straight horizontal wire of length L and diameter d metres, on surface:

R = ⎥⎦

⎤⎢⎣

⎡−⎟

⎞⎜⎝

⎛ 1

4ln

d

L

ρ . . . C3(5)

For a thin strip earthing electrode, the diameter can be replaced with a half-width of

the strip.

(f) As for Item (e), but buried h metres below surface:

R =

⎥⎥⎥

⎢⎢⎢

−⎟⎟⎟

⎜⎜⎜

⎛ 1

4 ln

2

1

)(dh

L

ρ . . . C3(6)

(g) Radial wires, number of wires n, on surface:

R = ⎥⎦

⎤⎢⎣

⎡−⎟

⎞⎜⎝

⎛ )(1

4 ln nN +

d

L

Lnπ

ρ . . . C3(7)

where

N(n) = nm sin

nm sin + 1 ln

1nm

1m/

/

- =

=

π

π

∑ . . . C3(8)

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 153: ASNZS 1768-2007

151 AS/NZS 1768:2007

COPYRIGHT

or for

n = 2 3 4 6 8 12 100

N(n) = 0.7 1.53 2.45 4.42 6.5 11.0 116

When the wires are buried at a depth of h metres then the diameter of the wire should

be replaced by the equivalent diameter—

d′ = 2

1

)(dh . . . C3(9)

(h) Ring of wire, radius of ring r metres:

R = d

r

r

16 ln

4 2π

ρ . . . C3(10)

or in terms of the circumference l

R = d

l

l2 ππ

ρ 8 ln . . . C3(11)

When the wire is buried at a depth h, the diameter of the wire should be replaced by

the equivalent diameter determined from Equation C3(9).

NOTES:

1 The above equations assume that the longitudinal resistance of the earthing electrodes can

be neglected. The resistance for an earth termination network, of such dimensions that the

voltage drop along the earthing electrodes or buried conductors must be considered, may

be obtained as follows:

2

1

2

1

oo

coth ⎥⎦

⎤⎢⎣

⎡⎥⎦

⎤⎢⎣

⎡=′

R

R

R

RRR . . . C3(12)

= R when Ro/R ≤ 0.4

= 2

1

)(o

RR when Ro/R ≥ 2

where R is the resistance calculated from the relevant equation and Ro is the

longitudinal resistance of the total length of wire.

2 The above equations also assume that the earthing electrodes on the surface are buried to

half their thickness or diameters; the lengths of rods and wires are much greater than their

diameters; the thickness of the plates is much smaller than the plate diameters and the

diameter smaller than the depth of burial; and that the angles between the radial wires are

equal.

3 Because of interaction, the obtainable earth resistance of two or more radial earthing

electrodes is higher than that for a single wire of the same length. The increase in

resistance is approximately as follows:

For two wires at right angles, energized at the joint, the earthing resistance is:

100

3RR +

where R is the resistance of a single straight wire of the same total length and

energized at one end. For a three-point star it is:

100

6RR +

and for four, six and eight-point stars, all energized at the centre, the resistances are:

.lyrespective100

65 + and

100

42 + ,

100

12

RR

RR

RR +

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 154: ASNZS 1768-2007

AS/NZS 1768:2007 152

COPYRIGHT

4 The equations apply to direct current or power-frequency alternating current energization.

For all practical purposes the resistance to a lightning surge of a typical structure LPS

earth termination network discussed in this Standard can be considered as being

somewhat lower than its direct current or power-frequency alternating current value.

C4 USE OF EARTHING ELECTRODES IN PARALLEL

In situations where a desired earthing resistance cannot be achieved with one earthing

electrode, a number of earthing electrodes may be used in parallel.

The combined resistance of parallel earthing electrodes is a complex function of a number

of factors, some of the more important being the number of earthing electrodes, their

dimensions, the separation between the earthing electrodes, the soil resistivity and the

configuration of the earthing electrodes.

Where the desired resistance can be achieved with only a few additional earthing electrodes

and if the separation between the earthing electrodes is greater than their lengths (see Note),

then the resultant resistance may be calculated by using the ordinary equation for

resistances in parallel. In other situations the combined resistance owing to the mutual

interaction between the earthing electrodes, will be always higher than given by this

equation.

NOTE: For practical purposes, the separation between vertical earthing electrodes can be taken as

twice the length of the earthing electrode.

For example, the combined resistance of two parallel earthing electrodes of diameter d

separated by a distance s, which is small compared with the earthing electrode’s length L, is

given by the following equation:

R = ⎥⎦

⎤⎢⎣

⎡−⎟

⎞⎜⎝

a

L

L1

2 nl

π

ρ . . . C4(1)

where

R = resistance, in ohms

ρ = soil resistivity, in ohm metres

L = buried length of earthing electrode, in metres

a′ = equivalent radius of the earthing electrode at the surface, in metres,

determined from the equation:

a′ = 4

1

2

1

2

1

2

1

] [ = ] ) ( )([ sdhsssdh ′′ . . . C4(2)

where

d = diameter of earthing electrodes, in metres

h = buried depth of earthing electrode, in metres

s = distance between two parallel earthing electrodes, in metres

s′ = distance from one earthing electrode to the image of the other earthing

electrode, in metres

NOTE: The term 2

1

)( ss ′ is the effective separation, and 2

1

)(s22

4 sh +=′ . An equation for

radial conductors is given in Paragraph C3(g).

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 155: ASNZS 1768-2007

153 AS/NZS 1768:2007

COPYRIGHT

C5 DRIVEN OR DRILLED EARTHING ELECTRODES

C5.1 General

The use of driven or drilled earthing electrodes combines economy of surface space with

efficiency of performance, and accesses clays and other conductive layers at depth. In

consequence, it is a preferred method of earthing electrode installation.

C5.2 Safety

The indiscriminate driving of earthing electrodes or drilling for their placement can lead to

damage of other services and, in the case of electricity supply cables, to the creation of a

significant hazard to the operator. As normally the drilled or driven rod will not be earthed

to a low impedance system, it will usually remain live and dangerous if it contacts a live

conductor. High pressure gas or hydrocarbon pipes also create a significant hazard, quite

apart from service failure aspects. Consequently, appropriate searches for such services

should be made before drilling or driving.

C5.3 Installation

The extent of the earthing electrode installation needed will depend on the variation in soil

resistivity with depth, and the resistance to be achieved. Earthing electrodes may be driven

directly into the ground or fitted into pre-drilled holes. In the latter case a bentonite/gypsum

slurry or other drilling mud would normally be used as a permanent resistance and soil

contact medium.

C5.4 Materials for earthing electrodes

Earthing electrodes should be made of metals not liable to be materially affected by

corrosion. Clause 4.7.2 describes the considerations involved in selecting earthing electrode

materials to minimize corrosion in service.

C5.5 Earthing electrode diameter

Although the resistance between the earth and the earthing electrode depends to a certain

extent on the area of the earthing electrode in contact with the soil, a large earthing

electrode of, say, 50 mm diameter does not decrease the resistance materially compared

with earthing electrodes of 13 mm or 20 mm diameter, which need to be only slightly larger

to achieve the same resistance.

For a driven earthing electrode, provided the required current-carrying capacity is met, the

minimum diameter will usually be determined by mechanical rather than electrical

considerations. The usual practice is to select a diameter that will give enough strength to

enable the earthing electrode to be driven into the soil of a particular location without

bending or splitting. Large diameter earthing electrodes are more difficult to drive than

small diameter earthing electrodes. For deep drilled earthing electrodes the size is selected

in the light of available drill diameters, requirements for connections (if any) and economy.

Strip earthing electrodes are commonly used.

C5.6 Depth of installation

The depth to which an earthing electrode is installed is usually the most important factor

affecting its earth resistance, first because the area of soil contacted increases directly with

the length of earthing electrode below the surface, and secondly because the soil resistivity

usually decreases with depth.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 156: ASNZS 1768-2007

AS/NZS 1768:2007 154

COPYRIGHT

This is shown by the measurements plotted in Figure C1 for a number of sites. For curves 1

and 2 it was known, by tests, that the soil down to a depth of between 6 m and 9 m

consisted of ballast, sand and gravel, below which was clay. The rapid reduction in

resistance when the earthing electrode penetrated the latter is very marked. The mean

resistivity up to a depth of 7 m in one case was 150 Ω.m, at 10 m the mean value for the

whole depth was 20 Ω.m due to the low resistivity of the clay stratum. Similarly for curve

4, the transition from gravelly soil to clay at a depth of about 1.5 m is very effective. For

curve 3, however, no such marked effect occurred although there is a gradual reduction in

average resistivity with increase in depth, as can be seen by comparison with the dotted

curves, which are calculated on the assumption of uniform resistivity.

FIGURE C1 CALCULATED AND MEASURED CURVES OF RESISTANCE

OF 13 mm DIAMETER DRIVEN ROD EARTHING ELECTRODES

C5.7 Sleeving of exposed part of vertical earthing electrode

Where side-flashing or step and touch potentials are a design problem on a driven earthing

electrode, it is good practice to sleeve the upper part of the earthing electrode with a

non-conducting pipe or heat shrink tubing of adequate weather resistance and electrical

insulation properties. For example, this could take the form of 2 mm thickness of

polyethylene or 4 mm thickness of PVC covering the upper 2 m to 3 m of the earthing

electrode.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 157: ASNZS 1768-2007

155 AS/NZS 1768:2007

COPYRIGHT

C5.8 Comparison with other earthing electrode types

The simplicity of driving an earthing electrode compared with making excavations for the

burying of plates or strips is obvious. The problem of the adequate packing of the soil

around the earthing electrode does not arise. The space occupied is small and, unlike plate

earthing electrodes, connections may be above ground. Moreover, where the permanent

moisture level or layer of low resistivity soil is available only at considerable depth below

the surface, earthing electrodes may be driven to depths that would be far beyond that

which would be practicable or economical for buried plate earthing electrodes.

However, where soil resistivity increases with depth, there is no point in driving an earthing

electrode any deeper as better results may be obtained by connecting a number of earthing

electrodes in parallel or by using a buried strip earthing electrode.

C6 BURIED STRIP EARTHING ELECTRODES

Buried strip earthing electrodes provide a solution to the problem of obtaining a low

resistance earth connection in locations where soil resistivity is high, particularly where

there is a superficial layer of soil over a stratum of rock and it is impracticable to drive an

earthing electrode. For a given cross-section, strip earthing electrodes have the advantage of

a greater surface area in contact with the soil.

The material for such earthing electrodes should be selected having regard to corrosion

compatibility with the protected structure (see Clause 4.7.2). For example, for a galvanized

steel tower, a 50 mm × 3 mm galvanized steel strip would be preferred. Where the earthing

electrode is totally isolated from other metals, e.g. on an isolated stone or timber structure,

any one of a variety of materials may be used. These include copper, galvanized iron, steel,

stainless steel, Ni-resist. The last two materials offer some additional corrosion resistance

in aerated soils, but with the disadvantage of higher electrical resistance and cost.

Backfilling and compacting the trench will enhance the early resistance performance of the

earthing electrode. The cross-section of the conductor has very little effect on the resistance

of the earth connection so that the strip or cable size is not important provided it affords

reasonable protection against mechanical damage and corrosion, and is of adequate current

surge capacity. (see Table 4.6 for typical dimensions).

The economics of depth of burial versus resistance performance do not warrant laying strip

earthing electrodes below 500 mm, unless the risk of mechanical damage requires this

additional protection.

The optimum resistance for a given amount of earthing electrode material is achieved if the

earthing electrode is buried in a straight single trench or in several trenches radiating from a

point. If laid in parallel lines, the trenches should be widely separated (see Paragraph C1

and the Notes to Paragraph C3).

C7 BURIED PLATE EARTHING ELECTRODES

This form of earthing electrode is now mainly restricted to tower footings or the like where

the civil works for the structure to be protected provide the facilities for the laying of the

earthing electrode. The performance/cost relationship does not support other than

such specific applications.

C8 CONCRETE FOOTING EARTHING ELECTRODES

This form of earthing electrode is one of the most effective both in cost and electrical

performance of currently available earth termination networks. For a given site it provides a

permanent, distributed, low resistance earthing electrode at very little cost above the

structural civil work.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 158: ASNZS 1768-2007

AS/NZS 1768:2007 156

COPYRIGHT

The vital part of the exercise is the planning, design and supervision of the construction, as

after concrete is poured it is impractical to address design deficiencies. If a sectional

measurement of earth resistance is desired, this will only be feasible at the appropriate stage

of construction.

As this earthing electrode is likely to be bonded deliberately or fortuitously to the

electricity supply service earthing system, and perhaps to other earthing systems, it is

important to consider the possibility of corrosion arising from contact with dissimilar

metals (see Clause 4.7.2). It may be necessary to address corrosion problems of rock

anchors by cathodic protection (see AS 2832.2).

The deliberate or fortuitous bonding of on-site fuel tanks, now relatively common adjacent

to building foundations, should also be taken into account in the design of LPS earthing

electrodes to ensure the earth discharge is from the earth termination network, i.e. the fuel

tanks are electrically screened.

C9 INSPECTION AND MAINTENANCE OF EARTHING ELECTRODES

The scheduling of earthing electrode maintenance inspections is the prerogative of the

system owner. However, the frequency of testing and the associated considerations are

listed below as a guide to good engineering practice. Data on the layout, materials of

construction data and electrical measurements pertaining to the original design should be

prepared and preserved as a guide to later performance. Soil resistivity data are likewise

useful for future comparison. The following practices are recommended:

(a) Inspections should be both physical and electrical.

(b) The inspections should be carried out at intervals of not less than two years.

Examples of the need for more frequent action would be if the earth termination

network is in a marine environment, subject to a high rate of corrosion. Such

installations may require inspection at intervals as frequent as once per year.

(c) The physical inspections should address corrosion or mechanical damage to visible

parts of the whole system, structural alterations that may have prejudiced the design

or operation of the system, or changes in the usage of the structure, e.g. fuel storage

added.

(d) Electrical tests should cover the continuity of the downconductors, the integrity of

bonding arrangements, and the resistance to earth of the earthing electrodes,

preferably individually as well as collectively. Methods of testing resistance to earth

are discussed in Paragraph C10. The continuity of downconductors should preferably

be checked by a high-current testing system (approximately 10 A) in order to detect

reduced current-carrying capacity resulting from fractures or other damage that may

be obscured from view.

(e) The enhancement or replacement of earthing electrodes to achieve a specified

resistance may be necessary, and if this is done it should be recorded along with other

test results. Restoration records of clamps, joints and fittings on downconductors or

earthing electrode terminations should also be kept as a future maintenance guide.

(f) Where uncertainty exists about the validity of inspection test results, comparison with

original design figures and data, together with the historical test records, will often

serve to indicate the extent of deterioration of the earthing electrodes. The change in

soil resistivity with rainfall can at times be particularly misleading, and test results

should be viewed with some suspicion if a significant reduction is observed in

resistance figures.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 159: ASNZS 1768-2007

157 AS/NZS 1768:2007

COPYRIGHT

C10 MEASUREMENT OF SOIL RESISTIVITY, EARTHING ELECTRODE

RESISTANCE AND EARTH TERMINATION NETWORK IMPEDANCE

C10.1 Determination of soil resistivity by test

C10.1.1 Four-pin method

The Wenner or four-pin method of soil resistivity measurement is commonly used. It

involves the use of four test pins (test electrodes) equally spaced in a straight line and

driven to the same depth d, not exceeding 5 percent of their separation s and not more than

1 m in any case (see Figure C2).

LEGEND:

s = test pin separation

d = depth of test pin: this must be small in relation to s.

i.e. not greater than 20

s and not in any case greater than 1 m

NOTES:

1 The above configuration will give a reading for ρ, by calculation, that is equivalent to the resistivity at

depth 0.75s.

2 If it is required to determine average resistivity to various depths at a given point ‘O’, the centre point O of

the test configuration is kept fixed and the test pin separation s increased outward from that point.

3 As the effects of d.c. polarization on the test pins would give a superimposed error on V, of the same order

as the small voltage being recorded, it is necessary to use an alternating electricity supply source, or if d.c.,

a cyclically-reversed source. The latter would also require a synchronous reversal of the indicating system.

FIGURE C2 FOUR-PIN METHOD OF SOIL RESISTIVITY MEASUREMENT

If a known current I is passed between the outer test pins, and the voltage drop V between

the inner test pins is measured, the ratio V/I gives a resistance R. If the earth were perfectly

homogeneous, i.e. of a constant resistivity ρ, then:

ρ = 2πsR . . . C10.1.1

where

s = test pin separation, in metres

ρ = average soil resistivity to a depth of s metres, in ohm metres

The soil is rarely homogeneous and the value ρ calculated from Equation C10.1.1 (called

the apparent resistivity) will be found to vary with the test pin separation s. It is from these

variations that deductions can be made as to the variation in the nature of the underlying

soil.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 160: ASNZS 1768-2007

AS/NZS 1768:2007 158

COPYRIGHT

Account should also be taken of seasonal variations of the soil, primarily because of

changing moisture content. By repeating the measurements with different values of test pin

separation, the average resistivity to various depths can be found and the results will

indicate whether an advantage is to be gained by installing deep-driven earthing electrodes

to reach strata of low resistivity.

In practice an indicating ohmmeter or null-reading bridge is used to measure the resistance

R from which soil resistivity ρ is calculated by using Equation C10.1.1.

C10.1.2 Instrumentation for soil resistivity measurement

Measurement of soil resistivity by the Wenner method (Paragraph C10.1.1) requires a four-

pin earth resistance tester. There are two main types, the traditional null-reading analogue

or the later microprocessor based digital. Originally the analogue types were powered by a

hand wound generator but these have been largely superseded by battery-powered models.

The majority of four-pin earth testers currently available are battery-powered digital

instruments providing a square wave output. Test frequencies are usually around 128 Hz for

the basic models. More capable models offer variable test frequencies to avoid possible

errors from interference frequencies present on the earth system. These instruments can also

provide automatic frequency selection which detects interference frequencies and

automatically selects the optimum test frequency to avoid measurement errors.

The output voltage of earth testers usually ranges from 20 to 50 V. Test current is governed

by the resistance of the load and instruments are usually rated on their short circuit current.

That is the current the instrument can generate with the terminals shorted. Typically the

short circuit current ranges from 10 mA for basic models to 250 mA for more capable

instruments.

The connections for a four-pin measurement of soil resistivity is shown in Figure C3.

LEGEND:

s = test pin separation

d = depth of test pin: this must be small in relation to s.

i.e. not greater than 20

s and not in any case greater than 1 m

C1 = Current terminal 1 on instrument (marked E on some instruments)

P1 = Potential terminal 1 on instrument (marked ES on some instruments)

C2 = Current terminal 2 on instrument (marked H on some instruments)

P2 = Potential terminal 2 on instrument (marked S on some instruments)

FIGURE C3 CONNECTIONS FOR EARTH RESISTIVITY TEST USING AN

INDICATING OHM METER OR NULL BALANCE BRIDGE FIGURE

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 161: ASNZS 1768-2007

159 AS/NZS 1768:2007

COPYRIGHT

C10.2 Earth resistance

C10.2.1 General procedure

Earth resistance is measured by applying a voltage to the earth electrode and measuring the

current passing through the electrode to earth. Resistance is calculated by the earth tester

using Ohm’s Law R=V/A. This is often referred to as the fall of potential method as shown

in Figure C4.

To create a path for the test current and to measure the voltage, a current is passed in a

potential test stake, which is placed in the soil outside the potential gradient area of the

electrode being measured.

The conduction of current through the soil is non-linear. Consequently, earth resistance

measurements will vary with different test voltages, currents and frequencies. Interference

voltage and frequency can be picked up by the test stakes. An earth resistance tester ideally

should provide variable test frequencies to avoid measurement errors from interference.

Earth resistance can be measured by a three-pin or four-pin measurement. The difference

between three-pin and four-pin testing is the number of connections to the electrode under

test. A three-pin test makes one connection to the earth electrode while a four-pin test

makes two. By making two connections to the electrode under test, the voltage is measured

at the earth electrode and not at the instrument. This eliminates any error caused by

resistance in the connecting lead and is generally regarded as the preferred method.

LEGEND:

C1 = Current terminal 1 on instrument (marked E on some instruments)

P1 = Potential terminal 1 on instrument (marked ES on some instruments)

C2 = Current terminal 2 on instrument (marked H on some instruments)

P2 = Potential terminal 2 on instrument (marked S on some instruments)

E = Earth electrode under test

P = Potential pin or stake

C = Current pin or stake (sometimes referred to as auxiliary stake)

RE = Resistance of earth electrode to ground

Rp = Resistance of potential pin to ground (sometimes referred to as Rs)

Rc = Resistance of current pin to ground (sometimes referred to as Rh)

V = Test voltage applied by instrument

I = Test current path

G = a.c. generator in instrument

NOTE: For three-pin measurement terminals C1 and P1 are bridged at the instrument

FIGURE C4 PRINCIPLE OF FOUR-PIN EARTH RESISTANCE MEASUREMENT

The fall of potential follows the relationship:

D = 2

I

V

ρ

π . . .C10.2.1

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 162: ASNZS 1768-2007

AS/NZS 1768:2007 160

COPYRIGHT

where

D = the distance from the test stake in metres

I = the test current in Amps

ρ = the soil resistivity in ohm-metres

V = the voltage at distance D from the test stake in Volts.

Consequently it is important that P be situated on the ‘flat’ part of the curve as in Figures

C5 and C6. If C is not sufficiently distant from E, there will be no flat part of the curve.

This can be established by moving P and retesting. If it varies, then C is too close to E.

As a general rule, C should be separated from E by not less than 10 times the length of E,

for homogenous ground, and P about half the distance from E to C.

FIGURE C5 FALL OF POTENTIAL AROUND AN EARTH ELECTRODE AND TEST

STAKES

FIGURE C6 EFFECT OF THE FALL OF POTENTIAL ON THE MEASUREMENT OF

EARTH RESISTANCE

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 163: ASNZS 1768-2007

161 AS/NZS 1768:2007

COPYRIGHT

C10.2.2 Test lead considerations

Because of the inhomogeneity or layering of the soil it is prudent practice to use as long a

lead from E to C as practical. In fact, for extreme conditions, such as a mountain top, where

the site may be on a volcanic core, it is not uncommon practice to use a 500 m or 1000 m

test lead of physically substantial construction. Testing with short leads merely gives a test

pin resistance to that small volume of ground encompassed by the electric field between E

and C, in a roughly hemispherical volume.

With very long leads a significant hazard arises. EPR from power fault currents or lightning

pulse can give rise to dangerous voltages between different parts of the earth’s surface. The

handling of leads of 500 m or greater should be accompanied by the careful use of

insulating gloves suitable for working at voltages of up to 500 V a.c. Test instruments may

require fitting with radiofrequency suppression devices to prevent the pickup of

high-frequency radio communication signals damaging the electronic detection equipment,

or producing erroneous readings.

Another condition requiring very long leads is the situation of an earthing electrode of

considerable dimensions, e.g. a 500 m strip earthing electrode, especially in high resistivity

ground such as a mountain top or sandy plain. In this case, the concept of ‘resistance to the

body of earth encompassed by the electric field’ above, requires a lead to C of the order of

500 m, at right angles to the run of the earthing electrode. The same safety considerations

apply.

C10.2.3 Instruments for earth resistance measurement

C10.2.3.1 General

The earth resistance of an earth electrode or group of electrodes can be measured by several

methods using various types of earth testers. It cannot be assumed that each method or each

type of instrument is suitable for every situation.

A four-pin earth tester (see Figure C7) as used for soil resistivity can also be used for

measuring earth resistance. Lower cost three-pin earth testers are also suitable for

measuring earth resistance but cannot be used to measure soil resistivity. Users must be

aware that measurements made with the three-pin method are susceptible to error from test

lead resistance.

Both three-pin and four-pin earth testers require the earth being measured to be

disconnection during measurement. This poses a major safety hazard should there be a

lightning strike or a fault current present during test. The use of a second downconductor

and consequent earth electrode will ensure that the LPS is always earthed during system

testing. (Refer to Clause 4.3.3(a)).

To eliminate the hazard and inconvenience of disconnecting the earth to be measured, the

selective method has been developed.

Another alternative is the stakeless method. This has the advantages of not requiring the

isolation of the earth electrode or the use of test stakes. This does however require the earth

system to have a secondary reliable solid bond to earth, such as a bond to the electrical

earth and/or metal water service. Users must be fully conversant with the earth circuitry,

otherwise measurements by this method can be misleading.

Each method has advantages and will produce reliable measurements if used in the

appropriate situations. There is no one method which can be used for every situation. This

has given rise to multi-method earth testers which combine all three methods into a single

instrument.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 164: ASNZS 1768-2007

AS/NZS 1768:2007 162

COPYRIGHT

C10.2.3.2 The three and four-pin method

FIGURE C7 THE THREE-PIN AND FOUR-PIN METHOD OF MEASURING EARTH

ELECTRODE RESISTANCE

C10.2.3.3 Selective method

To address the hazard of isolating electrodes under test and the inconvenience of

disconnecting and reconnecting, the selective method of measuring earth resistance was

developed (see Figure C8).

The principle of the selective method is the use of a clip-on current transformer (CT) to

measure the test current flowing in the earth electrode under test. Resistance is computed

from the actual current flowing to earth via the electrode. Current flowing to earth through

the remainder of the earth network is not measured and has no effect on the result.

FIGURE C8 SELECTIVE EARTH RESISTANCE MEASUREMENT

Both the three-/four-pin and selective methods of measuring earth resistance rely on test

stakes being placed, typically 50 to 100 m, or even further from the earth system being

tested. This is generally of no consequence in rural areas but it is seldom possible in cities

and towns where buildings are surrounded by pavement or the electrodes are in basements.

C10.2.3.4 Stakeless or clamp-on method

Stakeless testing provides benefits in developed areas as it is no longer necessary to find

suitable soil to place test stakes or to need to run out long test leads and wind them up at the

completion of tests. It provides a convenient method of measuring earth resistance in

locations which were previously difficult or impossible to measure by other methods. No

direct connection is made to the earthing system and maximim safety is achieved.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 165: ASNZS 1768-2007

163 AS/NZS 1768:2007

COPYRIGHT

Stakeless earth resistance testing requires a solidly earthed network in parallel with the

electrode to be tested to provide a path of negligible resistance to earth for the test current

(see Figures C9 and C10). For a valid reading, it is necessary that the resistance being

measured (Rx) is large compared to the parallel combination of the other interconnected

paths to earth (R1 to Rn). More specifically, the actual value measured is given by—

Rmeasured = Rx + (parallel combination of R1 to Rn)

Two clip-on CTs are used for this method. The test voltage is applied to one CT which is

used in reverse to induce a test current to flow in the earth network, the other CT is used as

before to measure the component of test current flowing through the electrode under test.

Earth resistance is computed in the same manner as for the selective method.

FIGURE C9 PRINCIPLE OF STAKELESS MEASUREMENT

Stakeless earth testing can be as an adaptation of the selective method by adding a second

CT or as a specially designed clamp-on tester where the two coils are incorporated into a

single jaw. Clamp-on earth testers can only function in this mode and cannot test by any

other method.

FIGURE C10 MEASUREMENT OF EARTH RESISTANCE OF A LIGHTNING SYSTEM

WHICH IS BONDED TO THE ELECTRICAL EARTH USING THE STAKELESS METHOD

C10.3 Isolation of surge impedance of an earth termination network from other

fortuitous earth paths

The measurement of electrode surge impedance in an LPS earth termination network

requires that the electrical condition specific to a lightning pulse be addressed. Typically

the rise time of a substantially unmodified lightning pulse is around 1 μs. This means that

fortuitously-bonded path lengths of more than a few tens of metres will present a reactive

component that prejudices the ability of such paths to divert a significant portion of the

total earth path current. This in turn requires the measuring system to reject such paths and

to measure the residual path—usually that to immediately adjacent earthing electrodes or

earth features.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 166: ASNZS 1768-2007

AS/NZS 1768:2007 164

COPYRIGHT

This can be achieved fairly simply but at some cost by utilizing a relatively high frequency

source of power for the three-pin test. Several excellent commercial instruments are

available that operate in the 25 kHz to 50 kHz range.

These are used in the same manner as other three-pin (and four-pin) test sets. The difference

in readings between these and the low-frequency test sets will often be quite spectacular

and will point out obvious reasons for observed catastrophic failure from lightning in

systems thought to be adequately earthed. In particular, the electricity supply service

neutral/earth connection bonded for 50 Hz equipotential protection to LPS earth termination

network can give a grossly misleading sense of security if it is read with a 108 Hz test set.

Typically, a one ohm reading can in reality be 100 Ω surge impedance, as measured by a

high frequency test set.

If a high frequency test set is unavailable, an alternative method with reasonable accuracy

may be used, based on the fall of potential curve around the electrode (see

Paragraph C10.2.1), similar to that used for testing substation earth mats.

Alternating current is applied between the earthing electrode (or its downconductor) and an

auxiliary test pin (see Figure C11). The portion of the current passing to earth via the

earthing electrode under test is measured by a clamp ammeter placed between the current

injection point and the earthing electrode entry to ground. The voltage to which this drives

the earthing electrode is measured by a flying lead voltmeter to a test pin sited in the ‘flat’

portion of the fall of potential curve. The resistance of the earthing electrode is a simple

R = V/I relationship, and is a good approximation to the surge impedance.

A skilled operator may elect to measure approximate lightning surge impedance at a site on

a long buried strip electrode by reduction of the length to the C2 electrode, using a

conventional 3 terminal test set. This requires both experience with the set and its

performance in various soil resistivities.

NOTE: No connections to bonding conductors should exist on the earth side of the current injection point.

FIGURE C11 MEASUREMENT OF EARTHING ELECTRODE SURGE IMPEDANCE

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 167: ASNZS 1768-2007

165 AS/NZS 1768:2007

COPYRIGHT

APPENDIX D

THE CALCULATION OF LIGHTNING DISCHARGE VOLTAGES AND REQUISITE SEPARATION DISTANCES FOR ISOLATION OF A LIGHTNING

PROTECTION SYSTEM

(Informative)

D1 GENERAL

In the first one or two microseconds of a lightning discharge, transient voltages occur on

the air terminal network and on the downconductors, which may be far greater than the

discharge voltages that apply during the remainder of the discharge. This is because the

discharge energy injected into the air terminal network at any instant is initially stored as

thermal energy in the conductors of the protection system prior to discharging into the

general mass of earth via the earth termination network. This transient voltage frequently

determines the separation distance required for isolation of the LPS, if it is desired to

isolate in accordance with Clause 4.16.2.3 as the preferred method of protection against

side-flash (see Clause 4.16.2.1).

The peak values of the transient voltages appearing at various points of the protection

system differ according to location, and increase with distance from the earth termination

measured along the route of the discharge through the protection system. At points very

near to a concentrated earth termination, the transient voltages are suppressed by the

discharge to earth and minimum values of discharge voltage and required clearance can be

readily calculated (see Note 1). These lower limits apply only at the base of the structure

and are given by the equations:

Ve = 150R . . . D1(1)

De = 0.3R . . . D1(2)

where

Ve = the discharge voltage at the base of the structure due to local EPR, in

kilovolts

R = the combined earth termination resistance, in ohms

De = the required clearance in air at the base of the structure, in metres

The complete transient voltage waveshape at all points of the protection system can be

calculated using travelling wave techniques and a computer, however substantial

simplifications allowing helpful easily-calculated estimates can frequently be made (see

Paragraph D2).

An estimate of the transient voltage at any one point of an LPS can often be made using a

conventional circuit theory approach (see Paragraph D3). This is possible because the

transient voltages can often be neglected due to the high insulation strength of air to

extremely brief voltage stresses.

Transient voltages at points remote from the earth termination depend both on the lightning

stroke current waveshape and the characteristics of the protection system. As indicated in

Paragraph B2.2 and Table B1 of Appendix B, lightning flashes generally have a number of

component strokes with differing waveshapes. The critical voltage may correspond to the

highest peak current of a first stroke or to the steepest wavefront (di/dt)max. of a subsequent

stroke.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 168: ASNZS 1768-2007

AS/NZS 1768:2007 166

COPYRIGHT

The design first and subsequent strokes used in this Standard are shown in Figure D1 (see

Note 2). The more severe of these cases was adopted in arriving at the required clearances

in Clause 4.16.2.3.

FIGURE D1 IDEALIZED LIGHTNING STROKE CURRENTS ADOPTED FOR DESIGN

PURPOSES

The electrical breakdown strength of air depends on the polarity of the applied voltage and

on the duration and shape of the voltage surge. In the studies conducted for this Standard,

the required clearances were estimated using the breakdown strength of air, shown in

Figure D2, which neglects some of these variables and should only be regarded as

approximate.

FIGURE D2 TIME DEPENDENCE OF THE ELECTRICAL BREAKDOWN STRENGTH OF

AIR

(approximation for the purpose of this Standard only)

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 169: ASNZS 1768-2007

167 AS/NZS 1768:2007

COPYRIGHT

In some cases where the transient voltage surges differed significantly from the waveshapes

(chopped and triangular waves) upon which the graph is based, a further adjustment was

made.

NOTES:

1 The lower limit of design discharge voltage is based on the assumed peak lightning current of

150 kA. The corresponding required clearance is based on a minimum electrical breakdown

strength of 500 kV/m in air.

2 The lightning flash is assumed to have a first stroke with Imax. of 150 kA and (di/dt)max. of

32.6 kA/μs and a steepest subsequent stroke with Imax. of 40 kA and (di/dt)max. of 200 kA/μs.

A more severe case would occur not more than once in each hundred lightning strikes to the

building, that is about once in a thousand years for a single 60 m high structure in a locality

with a moderate level of lightning activity (one strike per square kilometre per year).

D2 TRANSIENT VOLTAGE CALCULATIONS BY TRAVELLING WAVE

ANALYSIS

D2.1 Simplified travelling wave characteristics

An electric charge injected into one end of a conductor propagates along the conductor as a

travelling wave with velocity v given by:

v = )(

1

11CL

. . . D2.1(1)

where

v = velocity, in metres per second

L1 = the inductance per unit length, in henries per metre

C1 = the capacitance per unit length, in farads per metre

For a single bare conductor of radius r at a distance h above a perfect ground in free space,

L1 and C1 are given by:

L1 = r

ho

21n

μ . . . D2.1(2)

C1 =

r

h

o

21n

2πε

. . . D2.1(3)

where μo and εo are the permeability and permittivity of free space and the conductor is

assumed to be non-magnetic, i.e.

μo = 4π × 10-7

H/m, and εo = 8.85 × 10-12

F/m

In air, μ and ε differ only slightly from μo and εo, and the velocity of the travelling wave

becomes the velocity of light, c, in metres per second:

v =

)oo

εμ(

1 = c = 3 × 10

8 . . . D2.1(4)

(In an insulated cable with continuously earthed sheath and dielectric or relative

permittivity k (where k is typically 3 to 6), the velocity is reduced by the factor 1/ k and is

typically 0.5 c.)

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 170: ASNZS 1768-2007

AS/NZS 1768:2007 168

COPYRIGHT

For lossless surge propagation, the voltage e generated by a travelling wave with current i is

given by:

e = iZ . . . D2.1(5)

where

Z = ⎟⎟⎠

⎞⎜⎜⎝

1

1

C

Lis called the surge impedance of the conductor, and in free space

is given by:

Z = 60 1nr

h2

. . . D2.1(6)

where Z is in ohms.

When a travelling voltage wave in a conductor arrives at an electrical discontinuity, such as

an intersection of downconductors or the connection of a downconductor to an earth

termination, part of the travelling wave is transmitted and part is reflected.

If Z1 is the surge impedance of the conductor on which the wave is travelling prior to

reaching the discontinuity, and Z2 is impedance seen at the termination or combined parallel

surge impedance of conductors continuing beyond the junction or other discontinuity, then

the reflected surge v′, i′ is related to the incoming surge by the equations:

v′ = bv = v ⎟⎟⎠

⎞⎜⎜⎝

+

12

12

ZZ

ZZ . . . D2.1(7)

i′ = −bi = i ⎟⎟⎠

⎞⎜⎜⎝

+

21

211

ZZ

ZZ . . . D2.1(8)

and the combined transmitted wave v″, i″ beyond the discontinuity or at the termination is

given by:

v″ = av = v ⎟⎟⎠

⎞⎜⎜⎝

+12

2

ZZ

2Z= v(1 + b) . . . D2.1(9)

i″ = i ⎟⎟⎠

⎞⎜⎜⎝

+12

1

ZZ

2Z= i(1−b) . . . D2.1(10)

where

b = the reflection coefficient

a = the transmission coefficient

D2.2 Surge voltage calculation by lattice diagram

The LPS is represented by a simplified model in the form of nodes and branches. The nodes

are placed at junctions or impedance discontinuities. Each branch has a surge impedance,

and a travel time determined from its length and the surge velocity.

The earthing resistance at each earth termination is treated as a branch with surge

impedance equal to the earthing resistance in ohms and of infinite travel time.

Lattice diagram calculations are usually carried out by computer. Generally the program

calculates the response of the system to a unit step function current and the response to any

given input current wave is calculated as the superposition of the responses to the

succession of such step functions of various magnitudes, polarities and input times whose

sum closely approximates the desired input waveshape.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 171: ASNZS 1768-2007

169 AS/NZS 1768:2007

COPYRIGHT

For manual calculations only very simple models can be handled but triangular waveshapes

can be readily used. It is therefore necessary to consider whether parallel downconductors

can be represented by a single downconductor.

Example D1

A building 35 m high is protected by four vertical air terminals placed at each corner of the

flat roof and interconnected around the perimeter of the roof to four downconductors of

surge impedance 480 Ω that run vertically to earth at each corner. Each earth termination

has two to four driven earth stakes 3 m deep and 6 m apart to achieve a test resistance of

9 Ω to 10 Ω and a combined earthing resistance of 2.5 Ω.

Calculate the first voltage peaks of the response to stroke currents ia(t) and ib(t) having

waveshapes A and B of Figure D1, respectively.

The system may be modelled as shown in Figure D3. The four air terminals and

downconductors are represented by a single branch of surge impedance 120 Ω and length

40 m (say) terminated in a resistance (or reflectionless infinite branch) of impedance 2.5 Ω.

Nodes 1 and 2 lie at the top and the base of the building respectively.

For convenience of representation take i(t) as positive and adopt units of kiloamperes (kA),

kilovolts (kV), and microseconds (μs). Then the surge velocity C may be taken as 300 m/μs

and the branch (1, 2) travel time is T = 0.133 μs. The reflection coefficient b for surges

arriving at node 2 is evaluated as −0.95 so that 5 percent of the incident surge current at

node 2 leaks to earth with the remainder initially trapped on the protection system. The

reflection coefficient for surges returning to node 1 from 2 is evaluated as unity (the surge

impedance of the lightning discharge channel is neglected for this example). The lattice

diagram is developed as indicated in Figure D3(b).

FIGURE D3 CALCULATION OF SURGE VOLTAGE BY LATTICE DIAGRAM

The surge voltage v(t) at node 1 depends simply on the incident current i(t) until the first

reflection wave arrives at 0.266 μs(2T) and is given by—

v(t) = Zi(t), for 0 ≤ t ≤ 2T . . . D2. 2(1)

Because b is negative (−0.95) the first reflected voltage wave bv is negative and is doubled

on arrival at the open-circuited node 1, i.e. from the instant 2T, the first reflected wave bv is

again reflected as bv. The voltage at node 1 is varied by 2bv, and is given by—

v(t) = Zi(t) + 2bZi(t − 2T), for 2T < t ≤ 4T

= 120[i(t) − 1.9 i(t − 2T)], for 2T < t ≤ 4T . . . D2. 2(2)

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 172: ASNZS 1768-2007

AS/NZS 1768:2007 170

COPYRIGHT

For the first stroke current ia(t), (where ia is in kiloamperes and t is in microseconds) the

current waveshape in the period 0 < t ≤ 4T is a ramp of uniform slope:

ia(t) = 32.6t . . . D2. 2(3)

The response is a triangular wave given by—

va(t) = 120 [32.6t − 61.9(t − 2T)] . . . D2. 2(4)

for which the peak value occurs at t = 2T as shown in Figure D3(c).

For the subsequent stroke current ib(t), the current waveshape reaches its crest value at

t = 0.2 μs, which is prior to the arrival of the first reflection wave at t = T. The peak value

occurs at t = 0.2 μs, and as the waveshape to this time is a ramp of uniform slope

(ib(t) = 200t, t ≤ 0.2), the peak value is 4800 kV and the response takes the form shown in

Figure D3(c).

It should be noted that the transient oscillatory response is damped by the discharge to earth

occurring at node 2.

A travelling wave analysis for each stroke current was carried out by computer for a

10-metre structure with combined earthing resistance of 5 Ω, and for a case similar to the

above. The downconductor surge impedance was arbitrarily reduced to 40 Ω to allow for

corona and a lightning discharge channel surge impedance of 1500 Ω (a minimum value)

was used, increasing the damping of the transient oscillations. The response up to 6 μs is

shown in Figure D4.

The travelling wave analysis permits calculation of the voltage response at any point on the

LPS because of the distributed constant representation of the system.

D3 SURGE VOLTAGE CALCULATIONS BY LUMPED CIRCUIT

APPROXIMATIONS

The lumped circuit approximation precludes any assessment of the transient voltage

oscillations associated with travelling waves generated on the protection system, however,

elementary calculations generate the base lines about which any transient oscillations occur.

Example D2

A building 35 m high is protected in a similar manner to that of the example in

Paragraph D2.2. Each of four downconductors is assessed as having a length of 40 m and

the inductance in microhenries per metre is given by:

L1 = 0.2 1n r

h2 = 1.5 . . . D3(1)

where

h = the average height above ground of the four downconductors, in metres

r = typical radius of the four downconductors, in metres

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 173: ASNZS 1768-2007

171 AS/NZS 1768:2007

COPYRIGHT

Curves A: Response to design first stroke waveshape A of Figure D1

Curves B: Response to design subsequent stroke waveshape B of Figure D1

FIGURE D4 VOLTAGES ON LPSs—ILLUSTRATIVE CASES CALCULATED BY

SIMPLIFIED TRAVELLING WAVE ANALYSIS

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 174: ASNZS 1768-2007

AS/NZS 1768:2007 172

COPYRIGHT

The total inductance of the protection system is given by:

L = n

HL1

. . . D3(2)

where

H = the average length of downconductors from the point struck to earth, in

metres (this differs from the definition in Clause 4.15.2.3 because the

voltage at intermediate points cannot be calculated for multiple

downconductors using lumped circuit approximations)

n = the number of downconductors connected to a common air terminal

network (spacing of downconductors is assumed large enough for

mutual effects to be neglected)

The capacitance of the system is also neglected.

The equivalent circuit for calculating the voltage at roof level (node 1) and ground level

(node 2) is shown in Figure D5.

FIGURE D5 SIMPLIFIED LUMPED EQUIVALENT CIRCUIT

The voltage at node 1 with respect to remote earth is given by:

v1 (t) = i(t) R + L t

ti

d

)(d . . . D3(3)

The response to the idealized design stroke currents ia(t) and ib(t), calculated from this

equation, is shown in Figure D6.

It can be seen by comparison with Figure D4 that the simplified lumped circuit method is an

extremely useful tool in estimating system responses to the various lightning stroke

currents. In the case of first strokes, for which the transient oscillations have effectively

been damped by the time of the current peak, the voltage waveform calculated by this

method is also an adequate basis for estimating the required clearances for isolation.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 175: ASNZS 1768-2007

173 AS/NZS 1768:2007

COPYRIGHT

Curves A: Response to design first stroke waveshape A of Figure D1

Curves B: Response to design subsequent stroke waveshape B of Figure D1

FIGURE D6 VOLTAGES ON LPSs—ILLUSTRATIVE CASES CALCULATED BY

SIMPLIFIED LUMPED CIRCUIT ANALYSIS

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 176: ASNZS 1768-2007

AS/NZS 1768:2007 174

COPYRIGHT

APPENDIX E

EARTHING AND BONDING

(Informative)

E1 GENERAL

This Appendix provides additional information to Clause 5.5.2 on acceptable methods of

equipotential bonding. It is aimed at providing effective equipotential bonding between

services and the electrical installation earth/local earth.

E2 DEFINITIONS

For the purposes of this Appendix, the following definitions apply, in addition to those of

Clause 1.5.

E2.1 Common bonding network (CBN)

A common bonding network is formed by the interconnection of building steel and the

reinforcing steel in concrete etc. A CBN is an effective method to provide earthing and

bonding.

E2.2 Common utilities enclosure

A common utilities enclosure may contain, in separate compartments, the cabling and

equipment associated with the provision of service for example, electricity,

telecommunications, cable TV and water.

E2.3 Earth potential rise (EPR)

A rise in voltage of an earthing system and the surrounding soil with respect to a distant

earth.

NOTE: EPR is caused primarily when an earth fault on a HV power system produces a current

flow through the earthing system of a HV site.

E2.4 EPR hazard zone

The area around an earthing system bounded by a contour joining all points of EPR equal to

the maximum acceptable voltage below which no special precautions need to be taken to

protect telecommunication services, cabling providers and end-users.

E2.5 Main earthing bar (MEB)

Installed in the main switchboard (MSB), it provides a termination point for the main

earthing conductor, equipotential bonding conductors and protective earthing conductors.

E2.6 Main earthing conductor

The conductor connecting from the MEB to the electricity supply service earthing

electrode.

E2.7 Main switchboard (MSB)

Associated with the electricity supply service to the building. Contains the main earthing

bar (MEB), main neutral earth link and has a connection to the electricity supply service

earthing electrode. Where the multiple earthed neutral (MEN) system of earthing is

employed, a link exists between the MEB and the main neutral link (MEN link).

E2.8 Main distribution frame (MDF)

A distributor that provides, or is intended to provide, an electrical termination point for a

carrier’s lead-in cabling.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 177: ASNZS 1768-2007

175 AS/NZS 1768:2007

COPYRIGHT

E3 HAZARDOUS CONDITIONS ASSOCIATED WITH HV POWER EPR

E3.1 General

Placement of equipment, telecommunications plant and a connection to the structure

earthing system shall not take place where a hazardous EPR exists.

If a building is only supplied by 230 V a.c. single phase power or 400 V a.c. three phase

power , there will be no need to consider EPR unless the proposed installation is within the

EPR hazard zone of a HV site, as determined by AS/NZS 3835, Parts 1 and 2.

E3.2 HV sites of particular concern

A hazardous EPR may occur in the following sites:

(a) In or near a power generating station or power substation.

(b) Near a HV transformer or SWER transformer.

(c) In or near electrical traction systems.

(d) In or near any HV site located in an area of high soil resistivity (e.g. rocky or dry,

sandy terrain).

For requirements for safety in these situations refer to AS/NZS 3835, Parts 1 and 2.

E4 METHODS OF EQUIPOTENTIAL BONDING

E4.1 General

As stated in Clause 5.6.2, the objective of equipotential bonding is to reduce the potential

difference between various parts of the structure and the main earth bar (MEB). To

coordinate with the equipment insulation as specified in IEC 60950.1, the requirement is to

limit the potential difference to less than or equal to 1.5 kV under direct strike conditions.

It is particularly necessary for telecommunication line SPD bonding to ensure coordination

with the requirements of IEC 60950.1. To achieve less than or equal to 1.5 kV, based on the

assumed ∆U = 1 kV per m length for direct lightning strikes, the total length of bonding

conductor between the part being bonded and the MEB should be equal to or less than

1.5 m. This length is easy to achieve if all services enter at the same point in a small

structure.

In Australia, AS 4262.1 allows bonding conductors up to 10 m length, for safety of persons

using a telephone during a lightning storm, to coordinate with the handset breakdown

voltage of 7 kV required by AS/NZS 60950.1. Therefore in a poorly designed new small

structure, or in larger structures, bond wires up to 10 m may be used. However every

attempt should be made to achieve as short a bond wire as possible to ensure maximum

protection of people and equipment. In those exceptional cases where the total bonding

conductor length would to be greater than 10 m, an engineered solution should be applied.

E4.2 Using a bonding bar

To aid in the bonding of the various utility services it is preferable to use a bonding bar.

This bonding bar can be the MEB in the MSB but, for easy access, preferably a separate bar

provided in a common utilities enclosure or mounted as close as possible to the MSB.

Figure E1 shows the bonding bar and the connection of the various bonding conductors.

The bonding conductor requirements are—

(a) the bonding bar should be bonded to the MEB in the MSB with a short bonding

conductor, preferably less than 0.5 m long, via a disconnect link;

(b) the MEB should be bonded directly to the electrical installation earth electrode with

as short a conductor as possible and in accordance with AS/NZS 3000; and

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 178: ASNZS 1768-2007

AS/NZS 1768:2007 176

COPYRIGHT

(c) all other bonding conductors should be kept short, preferably less than 1 m long, and

be bonded to the bonding bar.

NOTE: To achieve a high level of protection for telecommunications services, the total

bonding conductor length, between the telecommunication SPD and the MEB, should be no

more than 1.5 m. Where due to practical reasons, this 1.5 m requirement cannot be met, a

total bonding conductor length of no more than 10 m will provide a reasonable level of

protection for people using a telephone. In those exceptional cases where the total bonding

conductor length would be greater than 10 m, a risk assessment according to AS 4262.1

should be performed.

Where the risk according to AS 4262.1 is considered particularly high, an engineered solution

should be applied which will give protection equivalent to that using short bond wires. Some

examples of engineering solutions which could be applied in these particularly high risk

situations are given in Paragraphs E4.3 and E4.4.

The LPS, antennas and other earthed objects likely to be struck by lightning should be

bonded so as to comply with the requirements of Clause 4.16.2.2. This LPS earth

termination network should be directly bonded to the electrical installation earth electrode

electrode. All bonding conductors should be labelled at the point of connection to the

bonding bar, the main earthing conductor or the electricity supply service earthing

electrode. Bonded joints should be accessible for maintenance.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 179: ASNZS 1768-2007

177 AS/NZS 1768:2007

COPYRIGHT

FIGURE E1 BONDING OF SERVICES

NOTES:

1 Refer to Paragraph E4.2 for bonding conductor lengths and other requirements.

2 Refer to AS/NZS 3000 for connection of the MEB to the electricity supply service earthing electrode.

The preferred method for new small buildings, e.g. domestic premises, is to co-locate the

entry of services next to the MSB or to use a combined utilities enclosure, see Figures E2

and E3.

For larger buildings an MDF will normally be installed and it may not be practicable to

achieve a short bonding conductor to the main earthing bar. Ideally, the MDF should be

installed as close as possible to the MSB. However, when the MDF is installed on a

different follor to the MSB, a bond to the nearest switchboard earthing system shall be

installed.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 180: ASNZS 1768-2007

AS/NZS 1768:2007 178

COPYRIGHT

NOTE: An LPS earthing system would be bonded to the electricity supply service earthing electrode.

FIGURE E2 CO-LOCATION OF SERVICES NEXT TO A SWITCHBOARD

See AS/ACIF S009 for further methods of connecting the telecommunications SPD to the

MEB.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 181: ASNZS 1768-2007

179 AS/NZS 1768:2007

COPYRIGHT

NOTE: An LPS earthing system would be bonded to the electricity supply service earthing electrode.

FIGURE E3 COMBINED UTILITIES ENCLOSURE

E4.3 Use of a common bonding network

A building with a properly bonded reinforced concrete floor effectively provides a common

bonding network (CBN). In this case, bonding can be achieved by bonding the various

services and SPDs directly to the CBN. This connection must be made by connecting

directly to the reinforcing mesh by a suitable method. The mesh must be electrically

continuous between the points of attachment. See Figure E4 which is an example showing a

building with a reinforced concrete floor. In a new building the reinforcing sheets should be

tied together with wire in accordance with Clause 4.5.2.4. In an existing building an attempt

should be made to measure the resistance of the reinforcing steel from one side of the slab

to the other. If continuity of the reinforcing steel is in doubt, e.g. the measurement was

made with the soil wet, a ring earth should be installed and bonded to the slab at every

earthing electrode.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 182: ASNZS 1768-2007

AS/NZS 1768:2007 180

COPYRIGHT

NOTE: An LPS earthing system would be bonded to the electricity supply service earthing electrode.

FIGURE E4 COMMON BONDING NETWORK (CBN)

E4.4 Use of a ring earth

A ring earth system may need to be installed for one or more reasons as follows:

(a) To interconnect an LPS electrode system when installed.

(b) To provide effective bonding of services to the MEB/local earth when this cannot be

achieved by one of the preferred methods shown in Figures E2 and E3.

The same ring earth system can be used for multiple purposes. When used as an LPS the

resistance to ground should be 10 Ω or less. When used only to bond incoming services,

there is no maximum resistance specified.

A ring earth, when required, should be provided by installing a bare conductor below

ground, see Figure E5. This conductor should encircle the building(s) and additional

earthing electrodes should be installed at each bonding point to the ring earth.

Where an LPS is installed, a ring earth should be used to interconnect all downconductors

unless the LPS is an integral part of the building. When a ring earth is installed as part of an

LPS system, equipotential bonding of services can be achieved by any one of the methods

shown in Figures E2 to E5 providing the conditions of the chosen method are achieved and

it complies with the requirements of AS/NZS 3000.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 183: ASNZS 1768-2007

181 AS/NZS 1768:2007

COPYRIGHT

NOTE: Where an LPS is installed the LPS downconductors would be bonded to this ring earth system. In this

case the 10 Ω resistance requirement applies.

FIGURE E5 RING EARTH

The method in Figure E5 is not as effective as the methods in Figures E2 to E4 but is an

attempt to minimize the potential difference between the telecommunications service SPD,

the MEB and ground.

Other valid engineered options can be used providing they reduce the potential difference to

an acceptable level.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 184: ASNZS 1768-2007

AS/NZS 1768:2007 182

COPYRIGHT

APPENDIX F

WAVESHAPES FOR ASSESSING THE SUSCEPTIBILITY OF EQUIPMENT TO TRANSIENT OVERVOLTAGES DUE TO LIGHTNING

(Informative)

Due to the random nature of lightning disturbances and the variable characteristics of the

transmission media (such as electricity supply and telecommunications service lines) these

transients exhibit wide waveshape variations. However, field and laboratory measurements,

confirmed by theoretical calculations, have led to the selection of a small number of

waveshapes that are representative of the majority of transients encountered in practice. The

value of these standard waveshapes lies in the uniform specification of transient protection

equipment. By using the same waveshapes and conditions to test the equipment,

manufacturers can quote results that may be directly compared between brands, enabling

the user to select an appropriate device.

The most common waveshapes used to represent transients on electricity supply service

lines are the 1.2/50 μs voltage waveform and the 8/20 μs current waveform. These two

waveshapes are shown in Figure F1, and Table F1 indicates their recommended applications

and magnitudes. Guidance on the use of these waveshapes in the testing of equipment is

given in AS 1931.1.

It is important to note that these waveshapes represent line input conditions expected under

practical conditions. Purchasers of protection equipment should ensure that equipment side

output voltages are reduced to be within the input tolerance envelope of the specified

equipment.

Tests have shown that the tolerable input voltage variations to electronic equipment can be

both time and magnitude dependent. Figure F2 shows two magnitude/time curves derived

for computing equipment. Long period variations can generally be corrected by line

conditioners while fast transients due to lightning need special devices. These usually

comprise non-linear devices to clamp overvoltages and subsequent filtering stages to

modify the residual waveshape. The purpose of such devices is to bring the residual

voltages from a lightning surge to within the safe operating zone.

The test voltage of Figure F1(a) can represent input levels to protection devices. The

residual voltage level is that seen at the output, or equipment side of the protection device,

when the impulse is applied at the crest of the a.c. voltage. This voltage level will be a

function of both the input pulse characteristics and the technical performance of the

protection device under test.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 185: ASNZS 1768-2007

183 AS/NZS 1768:2007

COPYRIGHT

FIGURE F1 STANDARD UNIDIRECTIONAL WAVESHAPES

FIGURE F2 TYPICAL VOLTAGE/TIME TOLERANCE OF COMPUTING EQUIPMENT

* See Paragraph G2, Ref 13.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 186: ASNZS 1768-2007

AS/NZS 1768:2007 184

COPYRIGHT

TABLE F1

RECOMMENDED APPLICATION FOR WAVESHAPES OF FIGURE F1

Location (see Figure F3)

Category Description Waveshape

Medium

exposure peak

amplitude

Type of load

Figure F1(a) 6 kV high impedance A Long final subcircuits and

electricity supply outlets Figure F1(b) 500 A low impedance

Figure F1(a) 6 kV high impedance B Major submains, short final

subcircuits and load centres Figure F1(b) 3 kA low impedance

Figure F1(a) 6 kV* high impedance C1 Service entrance, other than

below Figure F1(b) 10 kA low impedance

C2 Service entrance, building fed

by long overhead service lines,

or is a large industrial or

commercial premises

Figure F1(b) 20 kA low impedance

C3 Service entrance, building in a

high lightning area, or fitted

with a LPS

Figure F1(b) 50 kA low impedance

* The 6 kV amplitude shown here is a minimum value. Higher amplitudes may be used depending on generator

construction.

NOTES:

1 These test waveshape amplitudes were considered when formulating the recommended SPD surge ratings

of Table 5.1. In general, an SPD selected in accordance with Table 5.1 will handle a considerable number

of the corresponding test impulse amplitudes listed above.

2 Categories C2 and C3 do not show a voltage waveshape, as this large value current impulse is intended to

provide a measure of the SPD robustness, rather than allow a precise measurement of the let-through

voltage. See discussion of Up in Clause 5.6.3.5.

3 For testing the performance of SPDs on long, twisted pair telecommunications lines, a standard 10/700 μs

voltage surge waveform is often used. The standard 10/700 μs voltage surge generator is defined in ITU-

T-Recommendation K.44 (Figure A.3-1).

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 187: ASNZS 1768-2007

185 AS/NZS 1768:2007

COPYRIGHT

FIGURE F3 LOCATION CATEGORIES FOR APPLICATION

OF THE WAVESHAPES IN TABLE F1

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 188: ASNZS 1768-2007

AS/NZS 1768:2007 186

COPYRIGHT

APPENDIX G

REFERENCED DOCUMENTS

(Informative)

G1 REFERENCED STANDARDS AND REGULATORY DOCUMENTS

AS

1074 Steel tubes and tubulars for ordinary service

1214 Hot-dip galvanized coatings on threaded fasteners (ISO metric coarse

thread series)

1222 Steel conductors and stays—Bare overhead

1222.1 Part 1: Galvanized (SC/GZ)

1397 Steel sheet and strip—Hot-dipped zinc-coated or aluminium/zinc-coated

1432 Copper tubes for plumbing, gas fitting and drainage applications

1531 Conductors—Bare overhead—Aluminium and aluminium alloy

1565 Copper and copper alloys—Ingots and castings

1566 Copper and copper alloys—Rolled flat products

1746 Conductors—Bare overhead—Hard-drawn copper

1874 Aluminium and aluminium alloys—Ingots and castings

1931 High voltage testing techniques

1931.1 Part 1: General definitions and test requirements

2187 Explosives—Storage, transport and use

2187.2 Part 2: Use of explosives

2239 Galvanic (sacrificial) anodes for cathodic protection

2738 Copper and copper alloys—Compositions and designations of refinery

products, wrought products, ingots and castings

2832 Cathodic protection of metals

2832.1 Part 1: Pipes and cables

2832.2 Part 2: Compact buried structures

4070 Recommended practices for protection of low-voltage electrical

installations and equipment in MEN systems from transient overvoltages

4262 Telecommunication overvoltages

4262.1 Part 1: Protection of persons

4262.2 Part 2: Protection of equipment

AS/NZS

1020 The control of undesirable static electricity

1567 Copper and copper alloys—Wrought rods, bars and sections

1866 Aluminium and aluminium alloys—Extruded rod, bar, solid and hollow

shapes

2053 Conduits and fittings for electrical installations (all Parts)

2430 Classification of hazardous areas (all Parts)

3000 Electrical installations (known as the Australian/New Zealand Wiring

Rules)

3004 Electrical installations—Marinas and pleasure craft at low-voltage

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 189: ASNZS 1768-2007

187 AS/NZS 1768:2007

COPYRIGHT

AS/NZS

3100 Approval and test specification—General requirements for electrical

equipment

3191 Electric flexible cords

3835 Earth potential rise—Protection of telecommunications network users,

personnel and plant

3835.1 Part 1: Code of practice

3835.2 Part 2: Application guide

4853 Electrical hazards on metallic pipelines

5000 Electric cables—Polymeric insulated

5000.1 Part 1: For working voltages up to and including 0.6/1 (1.2) kV

60950 Information technology equipment—Safety

60950.1 Part 1: General requirements

NZS

3501 Specification for copper tubes for water, gas, and sanitation

4403 Code of practice for the storage, handling, and use of explosives

(Explosives Code)

IEC

60950 Information technology equipment—Safety

60950.1 Part 1: General requirements

61643 Low-voltage surge protective devices

61643-1 Part 1: Surge protective devices connected to low-voltage power

distribution systems—Requirements and tests

61643-12 Part 12: Surge protective devices connected to low-voltage power

distribution systems—Selection and application principles

62305 Protection against lightning

62305.1 Part 1: General principles

62305.2 Part 2: Risk management

62305.3 Part 3: Physical damage to structures and life hazard

62305.4 Part 4: Electrical and electronic systems within structures

ISO

10134 Small craft—Electrical devices—Lightning-protection systems

BS

1473 Specification for wrought aluminium and aluminium alloys for general

engineering purposes—Rivet, bolt and screw stock

6651 Code of practice for protection of structures against lightning

ANSI/NFPA

780 Standard for the installation of lightning protection systems

ASTM

A240M Standard specification for chromium and chromium-nickel stainless steel

plate, sheet and strip for pressure vessels and for general applications

AUSTEL

AS/ACIF S009 Installation requirements for customer cabling (Wiring Rules)

ITU-T

K.44 Resistibility tests for telecommunication equipment exposed to

overvoltages and overcurrents—Basic recommendation

K.66 Protection of customer premises from overvoltages Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 190: ASNZS 1768-2007

AS/NZS 1768:2007 188

COPYRIGHT

UL

1449 Standard for Transient Voltage Surge Suppressors

G2 REFERENCED TECHNICAL PAPERS AND PUBLICATIONS

1 HOLLE, R., LOPEZ, R.E. and ZIMMERMANS, D. Updated recommendations for

lightning safety–1998. Bulletin of the American Meteorological Society. 1999, vol 80,

1999, pp 2035-2041; see also HOLLE. R et al. Distances and times between flashes in

a storm. Proc. Int. Conf. on Lightning and Static Electricty (ICOLSE). Blackpool Set

2003. pp. 8.

2 ANDREWS, C.J., COOPER, M.A., DARVENIZA, M. and MACKERRAS, D. (Eds),

Lightning injury: Electrical, medical and legal aspects. Baton Rouge, Florida: CRC

Press, 1992. pp. 32.

3 HARTANO, Z.A. and ROBIAH, I. The collection surface concept as a reliable

method for predicting lightning strike location. Proc. 25th ICLP, Rhodes, Greece,

2000. pp. 328-333.

4 HARTANO, Z.A., ROBIAH, I. and DARVENIZA, M. A database of lightning

damage caused by bypasses of air terminals on buildings in Kuala Lumpur. Proc. 6th

SIDPA, Santos, Brazil, 2001. pp. 211-216.

5 D’ALESSANDRO, F. Improved placement of protective lightning rods on structures.

International Conference on Grounding and Earthing and 1st International Conference

on Lightning Physics and Effects. Brazil. 2004.

6 DARVENIZA, M. A modification to the ‘rolling sphere’ method for positioning air

terminals for lightning protection of buildings. Proc. 25th ICLP, Rhodes, Greece,

2000. pp. 904-908.

7 THOMSON, E.M. A critical assessment of the U.S. code for lightning protection of

boats. IEEE Transactions on Electromagnetic Compatibility. Vol 33, No. 2. 1991, pp

132-138.

8 RAKOV, V.A. and UMAN, M.A. Lightning: Physics and Effects. Cambridge

University Press. Cambridge USA. 2003 (Chapter 4.2).

9 KULESHOV, Y. and JAYARATNE, E.R. Estimates of lightning ground flash density

in Australia and its relationship to thunder-days. Aust. Met. Mag. 53, 2004. pp 189-

196.

10 NASA website, http://thunder.msfc.nasa.gov/data/OTDsummaries/

11 KULESHOV, Y., MACKERRAS, D. and DARVENIZA, M. Spatial distribution and

frequency of lightning activity and lightning flash density maps for Australia. Journal

of Geophysical Research. Vol 111, D19105, doi:10.1029/2005JD006982. 2006.

12 D’ALESSANDRO, F., JUDSON, W. AND HAVELKA, M. Long-term study of a

ground enhancing material. International Conference on Grounding and Earthing and

1st International Conference on Lightning Physics and Effects. Brazil. 2004.

13 KEY, T.S. Diagnosing power quality-related computer problems. IEEE Transactions

on Industry Applications. Vol 1A-15, No. 4, July/August 1979, pp. 381-384.

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 191: ASNZS 1768-2007

Standards Australia

Standards Australia is an independent company, limited by guarantee, which prepares and publishes

most of the voluntary technical and commercial standards used in Australia. These standards are

developed through an open process of consultation and consensus, in which all interested parties are

invited to participate. Through a Memorandum of Understanding with the Commonwealth

government, Standards Australia is recognized as Australia’s peak national standards body.

Standards New Zealand

The first national Standards organization was created in New Zealand in 1932. The Standards

Council of New Zealand is the national authority responsible for the production of Standards.

Standards New Zealand is the trading arm of the Standards Council established under the Standards

Act 1988.

Australian/New Zealand Standards

Under a Memorandum of Understanding between Standards Australia and Standards New Zealand,

Australian/New Zealand Standards are prepared by committees of experts from industry,

governments, consumers and other sectors. The requirements or recommendations contained

in published Standards are a consensus of the views of representative interests and also take

account of comments received from other sources. They reflect the latest scientific and industry

experience. Australian/New Zealand Standards are kept under continuous review after publication

and are updated regularly to take account of changing technology.

International Involvement

Standards Australia and Standards New Zealand are responsible for ensuring that the Australian

and New Zealand viewpoints are considered in the formulation of international Standards and that

the latest international experience is incorporated in national and Joint Standards. This role is vital

in assisting local industry to compete in international markets. Both organizations are the national

members of ISO (the International Organization for Standardization) and IEC (the International

Electrotechnical Commission).

Visit our web sites

www.standards.org.au www.standards.co.nz

www.standards.com.au

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009

Page 192: ASNZS 1768-2007

GPO Box 476 Sydney NSW 2001

Administration

Phone (02) 8206 6000

Fax (02) 8206 6001

Email [email protected]

Customer Service

Phone 1300 65 46 46

Fax 1300 65 49 49

Email [email protected]

Internet www.standards.org.au

Level 10 Radio New Zealand House

155 The Terrace Wellington 6001

(Private Bag 2439 Wellington 6020)

Phone (04) 498 5990

Fax (04) 498 5994

Customer Services (04) 498 5991

Information Service (04) 498 5992

Email [email protected]

Internet www.standards.co.nz

ISBN 0 7337 7967 0 Printed in Australia

Acc

esse

d by

UN

IVE

RS

ITY

OF

TAS

MA

NIA

on

11 S

ep 2

009