Date post: | 28-Dec-2015 |
Category: |
Documents |
Upload: | gwen-walton |
View: | 224 times |
Download: | 1 times |
ATCS IndustrialAutomatic Tube Cleaning System for Condensers and Heath Exchangers
ATCS Industrial:Automatic and Constant Operation
ATCS: Online Automatic Tube Cleaning
Trap Units
Injector
Ball Collector
Condenser
ATCS: Online Automatic Tube Cleaning for
Industrial Chillers
ATCS:System Components
ATCS provides significant savings in comparison to periodic cleaning
energy savings with ATCS
periodic cleaning each 6 months
ATCS – Continuous Automatic Cleaning
periodic cleaning
ATCS maintains process productivity in comparison to periodic cleaning
energy savings with ATCS
periodic cleaning each 6 months
ATCS – Continuous Automatic Cleaning
periodic cleaning
productivity without
productivity with ATCS
CQM ATCS Continuous Cleaning vs. Manual Off-Line Cleaning
CQM ATCS MANUAL OFF-LINE CLEANING
SYSTEM PERFORMANCE
Continuously operating at maximum efficiency.
Performance gradually decreases between treatments.
SHUTDOWN No shutdown normally. On-line cleaning.
Requires shutdown for cleaning.
DISPOSAL HASSLE No chemicals. No residues.
Cleaning chemicals & residues harmful to environment.
MANAGEMENT OVERHEAD
Fully automatic. Effortless maintenance.
High due to performance monitoring & manual cleaning.
ATCS maintains condenser tubes clean of fouling with the most efficient and
ecological technology
• Online operation
• Constant cleaning
• Ball technology
• Automatic operation
• Highly robust
100% productivity
100% efficiency
zero chemicals
zero atention
low maintenance
ATCS requires almost no maintenance.
Balls are replaced each 3 months.
ATCS avoids the use of chemicals and reduces or altogether prevents the need
of manual periodic cleaning of tubes
ATCS can be installed in both new and old heat Exchangers and has a useful
life more than 15 years
• Chemicals
• Mechanical Solutions
Wear out equipment and affect the environment
Wear out equipment
Advantages of ATCS over:
CQM ATCS Warranty: The heat exchanger tubes’ internal diameter
measured prior to the operation of ATCS, will be maintained as long as ATCS is
operated according to instructionssubject to and as long as the operating conditions
are maintained within the parameter ranges indicated at the start of operation
ATCS meets or exceeds the EC requirements, ISO 9001:2000 and
the Green Label certification standards.
ATCS – Individual Chiller Installation
ATCS Systems from 3” to 72”All over the World
CQM 72" system
AEM Moncalieri Power Station TORINO ITALY.
The electric capacity is 375 MW.manufactured by SIMENS.
Cooling, river water flow capacity around -22,000 m³/h.
Condenser has 7,000 tubes
Tube inside diameter 31 mm.
CQM: Online automatic cleaning solutions that work reliably, in thousands of installation
sites around the world:
For more information
National Power Contractors (PTY) Ltd
Tell 016 362 4659
www.natpower.co.za