Electronic scoring systems
SIUS AGIm Langhag 1 | CH-8307 Effretikon | Switzerland
Phone +41 52 354 60 60www.sius.com | [email protected]
Installation manualVersion for target LS10G2
ATE10 target elevator®
2
ATE10for LS10Electronic scoring systems
B-INBE- ATE10G2V6/7-en – 03/17
Table of contents
Installation 3–5Installation overview 3Example of an installation 4–5
Target elevator for airguns 6–11Target elevator ATE10G2V6 6Installation of print with mounting plate 7Installation of fixing bracket 8–9Assembly of target and bullet trap 9Laying and connection of cables 10Closing the target 11
Target elevator for small bore rifle 12–17Target elevator ATE10G2V7 12Installation of print with mounting plate 13Installation of fixing bracket 14Assembly of target and target holder 15Laying and connection of cables 16Closing the target 17Mounting of reinforced front frame for small bore rifle 17
Start-up 18–19
Function test 20–21
Page
Table of contents Target elevator
B-INBE- ATE10G2V6/7-en – 03/17
3
Electronic scoring systemsATE10for LS10
InstallationTarget elevator
Air rifle/air pistol installationSmall bore rifle installation
Installation overviewThe installation is divided into 3 article groups: article group target line (A), article group for cables and power supply (B) and article group firing line (C). The article group for cables and power supply (B) is designed for 10 lines maximum. In addition, power supply cables are required (connection cable: device to country specific plug) (Pos. 1).
Pos. Article no. Pcs. DescriptionA Article group target lineA1 LS10 1 Target 10m resp. 50mA2 ATE10G2V6/7 1 Automated target elevator for airguns resp. small bore rifleA3 KL001-2.0 2 Cable LTW male–fem 2.0mA4 KL001-T 1 T-Adapter fem/fem/male LTW IP67
B Article group cables and power supplyB1 NT211V0 1 Power supply for 10 lines 225W with LTW 230VB2 KL013 1 Y power cable for NT211B3 KL001-20.0 1 Cable LTW male–fem 20.0m (for 10m)B3 KL001-65.0 1 Cable LTW male–fem 65.0m (for 50m)B4 KL001-R 2 Terminating resistor, red, male LTW IP67
C Article group firing lineC1 M941 1 Monitor TFT 10.4“ (26cm)C2 CU941-CLUB 1 Control unit for clubs, schools etc. (ISSF approval phase 1 and 2)C2 CU941-ISSF 1 Control unit with software for ISSF competitions (ISSF- approval phase 1, 2 and 3)C3 KL003-2.0 1 Cable LTW male–RJ45 2.0mC4 KL001-T 1 T-Adapter fem/fem/male LTW IP67C5 KL001-2.0 1 Cable LTW male–fem 2.0mC6 RC941 1 Remote control RC941C7 D112-N 1 Thermal printer incl. power supply (optional)C8 AAG133 1 Barcode scanner (optional)C9 Monitor for spectators (on request)C10 SNI210-LANE 1 USB-LON-Dongle (yellow), option with PC/Laptop
SIL 1 Evaluation and display program SIUSLANE
1 Reference Country-specific power supply cable > AA1**
1
A1
A4
B1 B2
B4
B4
C1
C2
1
C4
C3
C5
A3
C8C6
A
B
C
C7
C9
B3
1 2 10
A2
1
Central PC for data acquisition,display and evaluation
> see brochureLarge installations and components
4
ATE10for LS10Electronic scoring systems
B-INBE- ATE10G2V6/7-en – 03/17
K ( 1 : 5 )
K
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
REV Änderungen Datum Name
Datum NameGez.Gepr.Norm.
Maßstab Blatt
Possible variant 2 single lane configuration
15.05.2014 ew
4
A3
.
.
D:\Products\SystemIntegration\Anlagebeispiele\Installation overview\Installation overview 10m Range\Installation overview 10m Range Variant 2 LS10G2 mit Kugelfang HS10.idw
10m Range
.
SIUS Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66
Shooters table 800x370mm(SIUS option or construction side)
Floor Box 300x300x200mm (construction side)
1/4
min. 100
Tube in ground ø50 (construction side)
cable cut mind. 100x60mm (construction side)
protection plate(construction side)
Installation Target elevator
Example of an installation
K ( 1 : 5 )
K
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
REV Änderungen Datum Name
Datum NameGez.Gepr.Norm.
Maßstab Blatt
Possible variant 2 single lane configuration
15.05.2014 ew
4
A3
.
.
D:\Products\SystemIntegration\Anlagebeispiele\Installation overview\Installation overview 10m Range\Installation overview 10m Range Variant 2 LS10G2 mit Kugelfang HS10.idw
10m Range
.
SIUS Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66
Shooters table 800x370mm(SIUS option or construction side)
Floor Box 300x300x200mm (construction side)
1/4
min. 100
Tube in ground ø50 (construction side)
cable cut mind. 100x60mm (construction side)
protection plate(construction side)
D
D
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
REV Änderungen Datum Name
Datum NameGez.Gepr.Norm.
Maßstab Blatt
Possible variant 2 single lane configuration
15.05.2014 ew
4
A2
.
.
D:\Products\SystemIntegration\Anlagebeispiele\Installation overview\Installation overview 10m Range\Installation overview 10m Range Variant 2 LS10G2 mit Kugelfang HS10.idw
10m Range
.
SIUS Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66
Line 1 Line 2 Line 10 Line 11
3/4
min. 100mm
1.4m
±0.05m
min. 1m
1x 220V/10Amps connector
Power-Supply for 10 lines (SIUS)
0.5m
±0.10m
0.8m
±0.10m
2x 220V/10Amps connectorfor Power-Supply(construction side)
D
D
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
REV Änderungen Datum Name
Datum NameGez.Gepr.Norm.
Maßstab Blatt
Possible variant 2 single lane configuration
15.05.2014 ew
4
A2
.
.
D:\Products\SystemIntegration\Anlagebeispiele\Installation overview\Installation overview 10m Range\Installation overview 10m Range Variant 2 LS10G2 mit Kugelfang HS10.idw
10m Range
.
SIUS Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66
Line 1 Line 2 Line 10 Line 11
3/4
min. 100mm
1.4m
±0.05m
min. 1m
1x 220V/10Amps connector
Power-Supply for 10 lines (SIUS)
0.5m
±0.10m
0.8m
±0.10m
2x 220V/10Amps connectorfor Power-Supply(construction side)
cable duct min. 100x60mm (construction side)
Line 1 Line 2 Line 11Line 10
B-INBE- ATE10G2V6/7-en – 03/17
5
Electronic scoring systemsATE10for LS10
InstallationTarget elevator
Sho
oter
s ta
ble
400x
369x
377m
m
(SIU
S o
ptio
n or
con
stru
ctio
n si
de)
Kab
alka
nal m
ind.
130
x60m
m
(bau
seiti
g)
Floo
r Box
300
x300
x200
mm
(con
stru
ctio
n si
de)
Ste
ckdo
se (b
ause
itig)
Tube
in g
roun
d Ø
50m
m
(con
stru
ctio
n si
de)
Ste
ckdo
se (b
ause
itig)
Floo
r cab
le d
uct m
in. 1
30x6
0mm
(c
onst
ruct
ion
side
)
1x 2
20V
/ 10A
mps
conn
ecto
r
1x 2
20V
/ 10A
mps
conn
ecto
r
6
ATE10for LS10Electronic scoring systems
B-INBE- ATE10G2V6/7-en – 03/17
Installation Target elevator airguns
Automated target elevator (3 positions) for airguns
Article no. ATE10G2V6 Automated target elevator (3 positions) for LS10G2
X ( 1 : 5 )
A-A ( 1 : 5 )
X
A A
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
REV Änderungen Datum Name
Datum NameGez.Gepr.Norm.
Maßstab Blatt
ATE10G2V6
Elektrischer Scheibenlift (3-Positionen) zu LS10G2
08.05.2014 ew
1
A2
.
.
D:\Products\TARGETS\Movers\ATE10\Mechanik\ATE10\ATE10G2V6.idw
.
1:5
Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66SIUS
15270
300
1523015
26015
4x10
500
800
1400
1665
697
470
34.5
76.9
Messebene
323
697
323
X ( 1 : 5 )
A-A ( 1 : 5 )
X
A A
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
REV Änderungen Datum Name
Datum NameGez.Gepr.Norm.
Maßstab Blatt
ATE10G2V6
Elektrischer Scheibenlift (3-Positionen) zu LS10G2
08.05.2014 ew
1
A2
.
.
D:\Products\TARGETS\Movers\ATE10\Mechanik\ATE10\ATE10G2V6.idw
.
1:5
Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66SIUS
15270
300
1523015
260
15
4x10
500
800
1400
1665
697
470
34.5
76.9
Messebene
323
697
323
1.1 MountingThe base plate enables the fixation of the target elevator to the ground.
X ( 1 : 5 )
A-A ( 1 : 5 )
X
A A
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
REV Änderungen Datum Name
Datum NameGez.Gepr.Norm.
Maßstab Blatt
ATE10G2V6
Elektrischer Scheibenlift (3-Positionen) zu LS10G2
08.05.2014 ew
1
A2
.
.
D:\Products\TARGETS\Movers\ATE10\Mechanik\ATE10\ATE10G2V6.idw
.
1:5
Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66SIUS
15270
300
1523015
260
15
4x10
500
800
1400
1665
697
470
34.5
76.9
Messebene
323
697
323
X ( 1 : 5 )
A-A ( 1 : 5 )
X
A A
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
REV Änderungen Datum Name
Datum NameGez.Gepr.Norm.
Maßstab Blatt
ATE10G2V6
Elektrischer Scheibenlift (3-Positionen) zu LS10G2
08.05.2014 ew
1
A2
.
.
D:\Products\TARGETS\Movers\ATE10\Mechanik\ATE10\ATE10G2V6.idw
.
1:5
Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66SIUS
15270
300
1523015
260
15
4x10
500
800
1400
1665
697
470
34.5
76.9
Messebene
323
697
323
B-INBE- ATE10G2V6/7-en – 03/17
7
Electronic scoring systemsATE10for LS10
InstallationTarget elevator airguns
Article no. ATE10D013 Installation of print (control electronics) with mounting plate
2.1 Pull out the mechanical interlock buttons.
2.2 Push the print under the mechanical interlock buttons and then to the right. Push the mechanical interlock buttons downwardsto lock them.
2.3 Insert the connection cable from print (control electronics)to the target print according to the draw.Affix it with the cable binder and plug it on both sides.
8
ATE10for LS10Electronic scoring systems
B-INBE- ATE10G2V6/7-en – 03/17
3.1 Loose and remove the screws on the right side of the bullet trap.
Article no. ATE10A067 Mounting of fixing bracket
3.2 Mounting of the fixing bracket on the bullet trap.
Installation Target elevator airguns
B-INBE- ATE10G2V6/7-en – 03/17
9
Electronic scoring systemsATE10for LS10
3.3 Mounting of the fixing bracket on the target elevatorThe fixing bracket enables the mounting on the target elevator.
Assembly of target and bullet trap
4.1 Hook the target down right into the bullet trap.
4.2 Next, push the locking plate down left to the sideand hook it in as well, so that the target is connectedwith the bullet trap on both sides.
InstallationTarget elevator airguns
10
ATE10for LS10Electronic scoring systems
B-INBE- ATE10G2V6/7-en – 03/17
Laying and connection of the cablesThe automated target elevator provides a cable with all necessary connections.
5.1 Insert the cable from behind into the target (not through the hole in the bullet trap) and affix it with the cable binder at the bullet trap.
Installation Target elevator airguns
5.2 Plug all cable connectors.Plug all cable connectors.
B-INBE- ATE10G2V6/7-en – 03/17
11
Electronic scoring systemsATE10for LS10
Closing the targetPull the target upwards and move it towards the bullet trap until the locking plate clicks into position.
InstallationTarget elevator airguns
12
ATE10for LS10Electronic scoring systems
B-INBE- ATE10G2V6/7-en – 03/17
Automated target elevator (3 positions) for small bore rifle
Article no. ATE10G2V7 Eletric target elevator (3 positions) for LS10G2
X ( 1 : 5 )
A-A ( 1 : 5 )
A A
X
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
REV Änderungen Datum Name
Datum NameGez.Gepr.Norm.
Maßstab Blatt
ATE10G2V7
Elektrischer Scheibenlift KK (3-Positionen) zu LS10G2
08.05.2014 ew
1
A2
.
.
D:\Products\TARGETS\Movers\ATE10\Mechanik\Entwicklung\Anleitung für Leibundgut\ATE10G2V7.idw
.
1:5
Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66SIUS
1400
1665
470
701
500
800
701
359
34.556.85
2.1
359
15 230
260
15270
15
300
15
4x10
Messebene
X ( 1 : 5 )
A-A ( 1 : 5 )
A A
X
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
REV Änderungen Datum Name
Datum NameGez.Gepr.Norm.
Maßstab Blatt
ATE10G2V7
Elektrischer Scheibenlift KK (3-Positionen) zu LS10G2
08.05.2014 ew
1
A2
.
.
D:\Products\TARGETS\Movers\ATE10\Mechanik\Entwicklung\Anleitung für Leibundgut\ATE10G2V7.idw
.
1:5
Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66SIUS
1400
1665
470
701
500
800
701
359
34.556.85
2.1
359
15 230
260
15
270
15
300
15
4x10
Messebene
Installation Target elevator small bore rifle
X ( 1 : 5 )
A-A ( 1 : 5 )
A A
X
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
REV Änderungen Datum Name
Datum NameGez.Gepr.Norm.
Maßstab Blatt
ATE10G2V7
Elektrischer Scheibenlift KK (3-Positionen) zu LS10G2
08.05.2014 ew
1
A2
.
.
D:\Products\TARGETS\Movers\ATE10\Mechanik\Entwicklung\Anleitung für Leibundgut\ATE10G2V7.idw
.
1:5
Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66SIUS
1400
1665
470
701
500
800
701
359
34.556.85
2.1
359
15 230
260
15
270
15
300
15
4x10
Messebene
1.1 MountingThe base plate enables the fixation of the target elevator to the ground.
X ( 1 : 5 )
A-A ( 1 : 5 )
X
A A
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
REV Änderungen Datum Name
Datum NameGez.Gepr.Norm.
Maßstab Blatt
ATE10G2V6
Elektrischer Scheibenlift (3-Positionen) zu LS10G2
08.05.2014 ew
1
A2
.
.
D:\Products\TARGETS\Movers\ATE10\Mechanik\ATE10\ATE10G2V6.idw
.
1:5
Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66SIUS
15270
300
1523015
260
15
4x10
500
800
1400
1665
697
470
34.5
76.9
Messebene
323
697
323
B-INBE- ATE10G2V6/7-en – 03/17
13
Electronic scoring systemsATE10for LS10
InstallationTarget elevator small bore rifle
Article no. ATE10D013 Installation of print (control electronics) with mounting plate
2.1 Pull out the mechanical interlock buttons.
2.2 Push the print under the mechanical interlock buttons and then to the right. Push the mechanical interlock buttons downwardsto lock them.
2.3 Insert the connection cable from print (control electronics)to the target print according to the draw.Affix it with the cable binder and plug it on both sides.
14
ATE10for LS10Electronic scoring systems
B-INBE- ATE10G2V6/7-en – 03/17
Article no. ATE10A056 Mounting of fixing bracket
Installation
3.2 Mounting on the target elevatorThe fixing bracket enables the mounting on the target elevator.
3.1 Mounting of the fixing bracketMounting of the fixing bracket on the target holder.
Target elevator small bore rifle
B-INBE- ATE10G2V6/7-en – 03/17
15
Electronic scoring systemsATE10for LS10
Installation
Assembly of target and target holder
4.1 Hook the target down right into the target holder.
4.2 Next, push the locking plate down left to the side and hook it in as well, so that the target is connected with the target holder on both sides.
Target elevator small bore rifle
16
ATE10for LS10Electronic scoring systems
B-INBE- ATE10G2V6/7-en – 03/17
Laying and connection of the cablesThe automated target elevator provides a cable with all necessary connections.
5.1 Insert the cable from behind through the hole in the bullet trap into the target.
Installation Target elevator small bore rifle
5.2 Plug all connectors of the cable in, then affix it with the cable binder through the provided hole in the rods of the target print.
B-INBE- ATE10G2V6/7-en – 03/17
-17
Electronic scoring systemsATE10for LS10
Installation
Closing the target
Article no. ATE10D014Mounting of the reinforced front frame for small bore rifle
7.1 After successful start-up of the installation (see page 18) the reinforced front frame is plugged onto the target.
6.1 Pull the target upwards and move it towards the target holder until the locking plate clicks into position.
Target elevator small bore rifle
18
ATE10for LS10Electronic scoring systems
B-INBE- ATE10G2V6/7-en – 03/17
Start-up
Check in advance
– Are all devices connected accordingly to the instructions?– Are there any visible damages on devices or cables? – Is the voltage of the power supplies set accordingly to the voltage of the electric power supply?
Operational readiness of the target
Before setting into operation, the target must be preconfigured, according to the installation manual for the LS10.http://sius.com/downloads/docu/Inst_Wartung_LS10_e.pdf> Start-up and function check.
Connecting to the electricity networkConnect all devices to the electricity network.
Configuration of control unit at firing point
The control unit (for example SA941 or PC/Laptop with LON-Dongle and software SIUSLANE) can be configured at this time.
Reference run
After proper installation and connecting to the electricity network the green operating lamp is glowing (A) and the target elevator moves automatically to the top position and remains there.
A
Target elevatorStart-up
B-INBE- ATE10G2V6/7-en – 03/17
19
Electronic scoring systemsATE10for LS10
Function check
Service-pin button
After pushing the service-pin button (B) the target elevator drives automatically to the next position (standing > kneeling > prone).
Choosing an exerciseTest the functionality by choosing an exercise on the control unit and by checking the position of the target elevator.
NOTEWhile the target elevator is moving, the target illumination isswitched off.The electrical supply of the target and the target elevator must beswitched off to restart the installation.
Function check
B
Target elevator
20