12
HPD - HPE - HPEDS Pompe a doppio supporto a uno o due stadi a norme API 610 - 10 a edizione One and two stage between-bearings pumps according to API 610 - 10 th edition Norms ATEX CERTIFIED Iso 9001 - Cert. N° 0633
Transcript
Page 1: ATEX HPD - HPE - HPEDS€¦ · HPE are two stage pumps with either single or double suction first stage impeller, depending on the design capacity. Both series of pumps correspond

HPD - HPE - HPEDSPompe a doppio supporto a uno o duestadi a norme API 610 - 10a edizioneOne and two stage between-bearingspumps according to API 610 - 10th editionNorms

ATEX CERTIFIEDIso 9001 - Cert. N° 0633

Page 2: ATEX HPD - HPE - HPEDS€¦ · HPE are two stage pumps with either single or double suction first stage impeller, depending on the design capacity. Both series of pumps correspond

Campo di selezione - 50 Hz Selection chart - 50 Hz

2950 rpm

1475 rpm

Le pompe HPE - HPEDS e HPDsono certificate ATEX su richiesta

Dosto 9

0032

Page 3: ATEX HPD - HPE - HPEDS€¦ · HPE are two stage pumps with either single or double suction first stage impeller, depending on the design capacity. Both series of pumps correspond

Campo di selezione - 60 Hz Selection chart - 60 Hz

3540 rpm

1770 rpm

HPE - HPEDS and HPD pumpsare ATEX certified upon request.

ssier according 94/9/REG B. b ii

stored

Page 4: ATEX HPD - HPE - HPEDS€¦ · HPE are two stage pumps with either single or double suction first stage impeller, depending on the design capacity. Both series of pumps correspond

HPE

Pompe a due stadi con la prima girante a singola aspirazione

Bearing isolator(optional)

Giranti bilanciate idraulicamente

Hydraulically balancedimpellers

Predisposizione per riscaldamentoo raffreddamento camera tenuta

Provision for stuffing box heating orcooling

Predisposizione perscambiatore di calore

Provision for oil cooler

Page 5: ATEX HPD - HPE - HPEDS€¦ · HPE are two stage pumps with either single or double suction first stage impeller, depending on the design capacity. Both series of pumps correspond

HPE

Two stage pumps with single suction first stage impeller

Predisposizione perscambiatore di calore

Provision for oil cooler

Bearing isolator(optional)

Page 6: ATEX HPD - HPE - HPEDS€¦ · HPE are two stage pumps with either single or double suction first stage impeller, depending on the design capacity. Both series of pumps correspond

HPE

DS

Pompe a due stadi con la prima girante a doppia aspirazione

Bearing isolator(optional)

Girante secondo stadiobilanciata idraulicamente

Hydraulically balanced2nd stage impeller

Predisposizione per riscaldamo raffreddamento camera te

Provision for stuffing box heacooling

Predisposizione perscambiatore di calore

Provision for oil cooler

Page 7: ATEX HPD - HPE - HPEDS€¦ · HPE are two stage pumps with either single or double suction first stage impeller, depending on the design capacity. Both series of pumps correspond

HPED

STwo stage pumps with double suction first stage impeller

mentoenuta

ting or

Predisposizione perscambiatore di calore

Provision for oil cooler

Bearing isolator(optional)

Girante primo stadio adoppia aspirazione

Double suction 1st stage impeller

Page 8: ATEX HPD - HPE - HPEDS€¦ · HPE are two stage pumps with either single or double suction first stage impeller, depending on the design capacity. Both series of pumps correspond

HPD

Pompe monostadio con girante a doppia aspirazione

Bearing isolator(optional)

Girante a doppia aspirazione

Double suction impeller

Predisposizione per riscaldamentoo raffreddamento camera tenuta

Provision for stuffing box heating orcooling

Predisposizione perscambiatore di calore

Provision for oil cooler

Page 9: ATEX HPD - HPE - HPEDS€¦ · HPE are two stage pumps with either single or double suction first stage impeller, depending on the design capacity. Both series of pumps correspond

HPD

Single stage double suction pumps

Predisposizione perscambiatore di calore

Provision for oil cooler

Bearing isolator(optional)

Page 10: ATEX HPD - HPE - HPEDS€¦ · HPE are two stage pumps with either single or double suction first stage impeller, depending on the design capacity. Both series of pumps correspond

Disegno di Sezione Sectional View

Part List & Materials of ConstructionNomenclatura & Materiali di costruzione

Page 11: ATEX HPD - HPE - HPEDS€¦ · HPE are two stage pumps with either single or double suction first stage impeller, depending on the design capacity. Both series of pumps correspond

Descrizione Description

Pompe centrifughe di processo a doppio supporto, sin-gola o doppia girante, progettate e costruite in accordoalla normativa API 610, 10a edizione. Le HPD sono pompe monostadio con girante a doppiaaspirazione e corpo a divisione radiale.Le HPE sono pompe a due stadi con la prima girante asingolo o doppio imbocco, secondo la portata di proget-to. Entrambe le linee di pompe corrispondono alla formacostruttiva BB2 prevista dalla normativa di riferimento. La costruzione compatta ed il generoso dimensiona-mento dei singoli componenti e dell'assieme le rendonoidonee ai servizi più gravosi: in queste pompe, le spinteassiali sono intrinsecamente bilanciate in modo daminimizzare il carico su albero e cuscinetti reggispinta.La cura nella progettazione, nella costruzione e nellabilanciatura dinamica delle parti rotanti garantisconoaffidabilità e livelli di vibrazioni particolarmente conte-nuti.Per i servizi a temperature elevate è previsto il raffred-damento dei cuscinetti mediante uno scambiatore dicalore realizzato in acciaio inossidabile e progettato inmodo da poter essere facilmente inserito e rimosso permanutenzione dal supporto cuscinetti, senza necessitàdi smontare il supporto stesso. In alternativa, e' previ-sto il raffreddamento ad aria su entrambi i lati dellapompa mediante ventole calettate sull'asse, anch'esseappositamente disegnate e realizzate in alluminio pres-sofuso. Le pompe HPE e HPD possono essere realiz-zate in tutte le combinazioni di materiali previste dallanormativa di riferimento ed in materiali speciali perservizi su liquidi aggressivi.

Single and two stage between bearing process pumpsdesigned and manufactured according to API 610, 10thed. HPD are single stage double suction radially splitcasing pumps.HPE are two stage pumps with either single or doublesuction first stage impeller, depending on the designcapacity.Both series of pumps correspond to type BB2 asdescribed in the reference standard.Compact design and generously sized componentsmake these pumps suitable for the most critical appli-cations: in the HPD and HPE pump series, the axialthrust is intrinsically balanced in order to minimize shaftand bearings loads.Care in design and manufacturing as well as dynamicbalancing of rotating parts will grant equipment reliabi-lity and smooth operation with low residual vibrations.For high temperature duties, cooling of the bearingscan be obtained by means of specifically designedstainless steel integral coolers which can easily beinstalled and removed for maintenance purposeswithout dismounting the bearing housing. As an alter-native, custom designed, integrally cast aluminium airfans can be fitted on both drive and non drive end .HPD and HPE pumps can be manufactured in all thematerials combination foreseen by the reference stan-dard and in special alloys for chemically aggressiveservices.

Page 12: ATEX HPD - HPE - HPEDS€¦ · HPE are two stage pumps with either single or double suction first stage impeller, depending on the design capacity. Both series of pumps correspond

Finder Pompe S.p.A.23807 MERATE (Lc) - ITALYVia Bergamo, 65Tel. +39 039 9982.1Fax +39 039 599267e-mail: [email protected]: www.finderpompe.com