AACC
QA
5V
9V
LIGHTNING
DETECTOR
V5
CHARLES
WENZEL
XX
©2013
LENNIE
ZINK
BB
BEEP
VOL
BASE STATIONDETECTOR BOARD
BOTTOM VIEW
AA CC
QA
5V
9V
LIGHTNING
DETECTOR
V5
CHARLES
WENZEL
XX
©2013
LENNIE
ZINK
BB
BEEP
VOL
IC2A
LM393
8
1
5
4
R183K3
R213K3
Q72N7000
B
E
C
C3120pF
BASE STATIONDETECTOR BOARD
PARTS LAYOUT
IN21mH
IN110mH
R1270K
R3270K
R21M
Q12N4401
C110pF
AntennaC20.001µF
C410µF
R410K
R53K9
Q32N4401
D21N914 (-)Pulse
R103K3
D31N914
R1210M
R111M
C5100µF16V
C7470µF16V
R141K
Pulse(+)R151K
R161K
R17180R
1 MT1
2 MT2
3 Gate
DetectorSW6
Q52N4403
Q6200V 6ATRIAC
TRIM1100KGain
R132K2
Q42N4403
SW4LAMP
R7220R
R610K
B
E
CB
E
C
B EC
B
E
C
IC1
MOC3010
TRIM350K
PRESET
D11N914
AEDLED
Counter
TESTSW
TESTSW
Q22N4403
115VACIN
(TRIAC)
115VACOUT
(TRIAC)
SW8BEEP
SW8SIREN
R224K7
LED2PRESET
TRIM210K
(Mtr Adj)
*R8820R R19
470K
R2010M
G
S
D
C64µ7F
R91K
C8(104)
*R8 BEEPER VOLUME
ATMOSPHERIC DISTURBANCE MONITORMAIN CIRCUIT BOARD V5
R111M
R103K3 R12
10M
R132K2
R141K
D31N914
0 to 100 mVDC OutC7
470mF16V
TRIM210K
Q52N4403
+5V
GND
FROMPULSES
2. SEVERITY METER
COLOR CODE: CYAN
CC
AA
4. 115 VACLAMP
R17180RFrom
Pulses
115V
115V
Q6200V 6ATRIAC
GMT2
MT1
COLOR CODE: ORANGE
1 AMPIC1
MOC3010
1
2
3
5
4
6BB
LAMPSW4
BZ1
6. BEEP
BB
R7820R
SW5BEEP
SW4 LAMP
1. BASIC LIGHTNING DETECTOR
R3270K
C110pF
IN110mH
IN21mH
C2.001mF
R1270K
SW3TEST
R410K
R53K9
C5100mF
16V
Q32N4401
D21N914
TRIM1100K
C410mF
(-) to (+)Pulse Out
GND
Q12N4401
D11N914
AA
Q22N4403
R21M
QA
Q1 COLLECTOR OUT COLOR CODE: RED
C3120pF
5V IN
SW6DET
Q42N4403
R610K
BB
(+) to (-)Pulse Out
SW5 BEEP
COUNTER
R7220R
*R8820R
C64•7mF
16V
R91K
*R8 BEEPER VOLUME
COLOR CODE: BROWN
LED1ULTRA-BRIGHT
R151K R16
1K
5V
3. LED
AA
R1810K
R2010M
TRIM350K
PRESETADJUST
R213K3 Q7
2N7000IC2A
LM393
GND
+5V
0-100 mVfrom Meter Ckt.
2
38
1
49V OUT200mAMAX
5. PRESET LEVEL
SW7SIREN
+9V
R19470K
R224K7
GND
LOAD
COLOR CODE: GOLD
CC
XX
C8(104)
Q7: N-Channel Enhancement Mode Field Effect Transistor
C8 SETS A FULL ON/OFF STATE
G
D
S
METERLAMPLEDS
ML1-ML3STRAW HATCOOL WHITE
LED 3.2FV
9V
©2013Lennie Zink
GND
Reset
+9V
D C B A G F
Common
Test3 1
2
E
BB
3 DIGIT COUNTER
V2 ©2013
LENNIE ZINK
GND
FB
A
G
C E
D
3
21
3 DIGIT COUNTER
V2 ©2013
LENNIE ZINK
GND
FB
A
G
CE
D
3
2 1
3DIGITCOUNTER
V2©2013
LENNIEZINK
GND
Reset
+9V
DCBAGF
Common
Test31
2
E
BB
3DIGITCOUNTER
V2©2013
LENNIEZINK
DISPLAY BOARDBOTTOM VIEW
LOGIC BOARDBOTTOM VIEW
LOGIC BOARDPARTS LAYOUT
CONNECTIONS
a13 to 25+21+16
b12 24+20+15
c11 4+8+13
d10 2+7+11
e9 1+6+10
f15 27+23+17
g14 28+22+12
28 27 26 25 24 23 22 21 20 19 18 17 16 15
1 2 3 4 5 6 7 8 9 10 11 12 13 14
g14
b12
c11
a13
d10
e9
f15
DS315
DS21
DS12
R2470KC2
10n(0.01)
SW1
e9
f15
b12
a13
g14
c11
d10
R6-R12330R
R1470K
C110nF(O.O1)
16 15 14 13 12 11 10 9IC3
14511
R154K7
R134K7
R144K7C3
1nF
IC2
14553
IC1
4093
R3100K
18
9 16
R41M
R51M
D11N4148
18
19
3
Q22N4403
Q12N4403
Q32N4403
1
14
7
8
1 2 3 4 5 6 7 8
C43.3mF
B
E
C
B
E
C
B
E
C
PARTS LAYOUTDISPLAY BOARD
Note: 12 AWG solid wire is soldered to the display boardextendingout the back far enough to piggy-back the companion circuitboard. Slightly larger holes allow board to be removed.Solder is applied to wire at stop points. Half-inch tails are slightlybent to keep board in place yet allow removal.
THREE
DIGIT COUNTER V4
Debounce Circuit
13
12
11
10
9
15
14
a
b
c
d
e
f
g
9V
a13 to 25+21+16
b12 24+20+15
c11 4+8+13
d10 2+7+11
e9 1+6+10
f15 27+23+17
g14 28+22+12
A B C D
IC314511
IC214553
3, 26Com
f27
d2
c4
a25
b24
e1
g28
18Com
f17
d11
c13
a16
b15
e10
g12
19Com
f23
d7
c8
a21
b20
e6
g22
16 21 25
R6330R
15 20 24
R7330R
2 7 11 17 23 27
R8330R
4
8
13
1 6 10
12 22 28R12
330R
R9330R R10
330RR11
330R
3 26 19 18
15
1
2
R134K7
R144K7
R154K7
Q12N4403
Q22N4403
Q32N4403
11
8
C31nF
(.001)
43R51M
LATCH
CLOCK
RESET
CARRY
16
13
12
10
14
5
8
3 4 16
R41M
R3100K
7
14
31
2
C110nF(0.01)
SWNOT USED
COUNT
108
9
45
6
C210nF(0.01)
SW2RESET
R2470K
IC1B4093
IC1C4093
IC1A4093
B
E F
G
DS1
DS2
DS3
7 1 2 6
9 7 6 5
3-DIGIT LED DISPLAYCOMMON CATHODELDT-C514RI LUMEXDIGIKEY 67-1425-ND
SW1D1
1N4148
3 12
BB
A
C
D 3 12
5VFROM
PULSES
1112
13
IC1D4093 ©2013
Lennie Zink
ATMOSPHERIC DISTURBANCE MONITOR
ES
CO
PE
V-
7
LENNIE ZINK
©2013
9V
SW
Z
B
BOTTOM VIEW
ESCOPEV
-
7
LENNIEZINK
©2013
9V
SW
Z
B
NE1
R110M
ANT
R41K
R7390R
VR25K
BALANCE
Q12N3819
B
E
C
B
E
CQ4
2N4401
+9V G SD
R5560K
PARTS LAYOUT
Q32N4401
VR150K
ZERO
Q22N3819
GS D
R31K
R210K
R64M7
G
D
S
PIZZA PANANTENNA
ELECTROSCOPE V7
+9V
R7390R
Q32N4401
Q42N4401
VR25K
BALANCE
LED1
Q12N3819
R31K
R110M
GND
R5560K
NE1
LED2
R41K
GNDMETALCASE
VR150K
ZERO
R210K
M10-100mA
G
D
S
R64M7
Q22N3819
©2013Lennie Zink
ATMOSPHERIC DISTURBANCE MONITOR
9V
©2013 LENNIE ZINK
STORM SIREN V2
BOTTOM VIEW
9V
©2013LENNIEZINK
STORMSIRENV3
BE
C
R5100K
R6330K
C147mF16V
Q32N4401
Q42N4403
Q22N4403
R3100K
C3104pF
R722K
R833K
R91K5
C4100mF16V
R11100R
R10220R
BE
C
BE
C
Q12N4401
C222mF16V
BE C
R133K
R4560K
R210K
PARTS LAYOUT
Q22N4403
SPK18 ohm
Q42N4403
C147mF16V
C3104pF
9V
EMERGENCY SIREN SIMULATOR
C4100mF
16V
9V
R3100K
Q32N4401
R5100K
R6330K
R722K
R833K
R91K5
R10220R
R11100R
C222mF16V
R133K
Q12N4401
XX
R4560K
R210K
A simple and fantastic circuit! Operation issmooth and can be triggered with a low voltage.
When switched off, the siren soundsuntil it reaches its low frequency cut off.The decay is long so it takes a while!
Original version (Wenzel) wailed whenpowered on. This feature was notdesirable for this project.
SW7SIREN
SWOPTIONAL
©2013Lennie Zink
ATMOSPHERIC DISTURBANCE MONITOR
©2013 LENNIE ZINK
MTR
RAIN DETECTOR V10
DEW
RN
BOTTOM VIEW
©2013LENNIEZINK
MTR
RAINDETECTORV10
DEW
RN
PARTS LAYOUT
R31K
B
C
E
R7680K
Q42N4403
B
C
E
Q52N4403
VR101M R12
1K
RAIN
B
C
E
Q72N4403
B
C
E
BC E
SENSOR
R14100K
R11220R
R164K7
R2127K
R24100K
R22470K
R231M
Q112N4401
C1(104)
VR9100K BZ1
SW5B
SW5C
SW9E
R1310K
Q82N4401
R15100K
B
C
E
Q92N4403
R1915K
B
E
C
R2220R
R1710K
R1833K
SW5CF
Q102N4403
R2010K
C247mF
B
E
C
B
C
E
Q12N4403
RAIN
Q22N4401
B
C
E
Q32N4403R5
100K
R64K7
R410K
R81K
B
C
E
VR11M
C222mF
DEW METER RAIN/SENSOR
9V
RAIN BUZZER/SW
Q62N4401
MOISTURE DETECTOR METER WITH RAIN ALARM V10
R81K
RED
BLACK
Q42N4403
Q52N4403
R7680K
VR101M
R11220R
R164K7
Q62N4401
RAININTENSITY
SW9DPDTRAIN
ALARM
C247mF
9V
GND
RAIN
DETECTOR
ALARM
FLASHER
Q112N4401
R231M
R14100K
Q72N4403
R24100K
R22470K
R121K
Q102N4403
R2127K
*C10.1mF
*C1, C2SUPPRESSES60Hz NOISE IN LONG LEADS
VR9100K
Q92N4403
Q82N4401
R15100K
R1833K
R1310K
R1710K
R1915K
A
B CD
FE
R2010K
Q12N4403
VR11M
R2220R
R64K7
Q22N4401
DEW
DETECTOR
R5100K
R31K
R410K
Q32N4403
*C222mF
©2013Lennie Zink
ATMOSPHERIC DISTURBANCE MONITOR
++V
+V
DOUBLE
POWER
SUPPLY
BATTERY
BACKUP
©2013
LENNIE ZINK
+12
VD
C
12-1
8
VA
C
CUT
++V
+V
DOUBLE
POWER
SUPPLY
BATTERY
BACKUP
©2013
LENNIEZINK
+12VDC
12-18
VAC
CUT
COMPONENTLAYOUT
BOTTOMVIEW
IGND
O
C1
3300mF 35-50V
C110µF 35v
C310µF 35v
C20.1µF
C40.1µF
SD21N5818
IGND
O
SD11N5818
CUTFOR BATTERYBACKUP USE
9V RUNS HOT.EXTRA HEAT SINK
SD21N5818
7805
120VAC12VCT1.2A
(3 VOLTS OVER HIGHEST OUTPUT)
C1330010,00035-50
-µF
V
C210µF35V
C30.1µF
7809
C410µF35V
C50.1µF
+5V +9V
GND
5V 9V
WIRE CODE:
SW8POWER
3 TERMINALBARREL
POWER PLUG
POWER SUPPLYWITH BATTERY BACKUP
SD11N5818
©2013Lennie Zink
ATMOSPHERIC DISTURBANCE MONITOR
©2013Lennie Zink
ATMOSPHERIC DISTURBANCE MONITOR
©2013Lennie Zink
ATMOSPHERIC DISTURBANCE MONITOR
©2013Lennie Zink
ATMOSPHERIC DISTURBANCE MONITOR
Updated Label
FUSEFUSE
DEW RAIN
INTENSITY
4 5 6 78321 100
DISCHARGE
SEVERITY
4 5 6 78321 100
ATMOSPHERIC
CHARGE
0 1 2 34123 5 64
SW6 SW7
SW3 SW4SW2
SW8
SW9
SW5
SW1
LAYOUT
BEEP
On
Off
DET
On
Off
AED COUNT
TESTRESETOn
Off
LAMPCOUNT
SIREN
A Dtmospheric isturbance
onitorM
POWER
RAINDEWPRESET
Off
RAINWARNING
HOBBY ELECTRONICS, INC.HOBBY ELECTRONICS, INC.
CHARGE AtmosphericElectrical
Discharge
TRANSFORMERFUSE
TRIACLAMP FUSE
RAINSENSOR
TRIACCONTROLLED
LAMP
115 VACLINE CORD
ATMOSPHERICCHARGEANTENNA
ELECTRICALDISCHARGEANTENNA
with Battery Backup
12 VOLTBATTERY
©2013Lennie Zink
POWER and BEEPswitches wereswapped when
upgraded tobattery backup.
ATMOSPHERIC DISTURBANCE MONITOR
Updated Label
BEEP
On
Off
DET
On
Off
AED COUNT
TESTRESETOn
Off
LAMPCOUNT
SIREN
A Dtmospheric isturbance
onitorM
POWER
RAINDEWPRESET
Off
RAINWARNING
HOBBY ELECTRONICS, INC.HOBBY ELECTRONICS, INC.
CHARGE AtmosphericElectrical
Discharge
TRANSFORMERFUSE
TRIACLAMP FUSE
RAINSENSOR
TRIACCONTROLLED
LAMP
115 VACLINE CORD
ATMOSPHERICCHARGEANTENNA
ELECTRICALDISCHARGEANTENNA
with Battery Backup
12 VOLTBATTERY
©2013Lennie Zink
POWER and BEEPswitches wereswapped when
upgraded tobattery backup.
ATMOSPHERIC DISTURBANCE MONITOR