DR. BANDAR MOHAMMED AL-QAHTANI, M.D KSMC. AUDIOLOGY IN ORL . Tympanic mem & Ossicular Amplification 22:1 in total 1.3:1 maleus to incus (lever action) 17 :1 TM surface to stapes footplate problem in transmission leads to CHL . Anatomy of hearing organ THE COCHLEA. - PowerPoint PPT Presentation
Popular Tags:
30
AUDIOLOGY IN ORL DR. BANDAR MOHAMMED AL- QAHTANI, M.D KSMC
Transcript
Page 1: AUDIOLOGY IN ORL

AUDIOLOGY IN ORL

DR. BANDAR MOHAMMED AL-QAHTANI, M.D

KSMC

Page 2: AUDIOLOGY IN ORL

2

Tympanic mem & Ossicular Amplification22:1 in total 1.3:1 maleus to incus (lever action) 17 :1 TM surface to stapes footplateproblem in transmission leads to CHL

Page 3: AUDIOLOGY IN ORL

3

Anatomy of hearing organTHE COCHLEA

Page 4: AUDIOLOGY IN ORL

4

Traveling wave & Tonotopic organization

Traveling wave & Tonotopic organization

High frequency at base and low frequency at apexproblem inside the cochlea transmission leads to SNHL

Page 5: AUDIOLOGY IN ORL

5

Auditory Assessment Clinical vs audiometric tests Clinical : - finger friction - watch test - speech test - tuning fork test

Page 6: AUDIOLOGY IN ORL

6

Audiometric tests : subjective vs objective tests - pure tone audiometry - speech audiometry - impedance audiometry a-tympanometry b-acoustic reflex

Page 7: AUDIOLOGY IN ORL

7

Anatomy

Page 8: AUDIOLOGY IN ORL

8

Audiometric Assessment

Pure Tone Audiometry Speech Audiometry Acoustic Immittance (impedance test

) Auditory Brainstem Responses Electrocochleography Otoacoustic Emissions

Page 9: AUDIOLOGY IN ORL

9

Pure Tone Audiometry Most common ,subjective test Air conduction testing

Frequencies 125,250,500,1000,2000,4000,8000 HZ

Bone conduction testing 250,500,1000,2000,4000 HZ

Page 10: AUDIOLOGY IN ORL

10

Pure tone audiometry

Page 11: AUDIOLOGY IN ORL

11

USES As baseline test (pre op and post op) To differentiate the conductive vs sensorineural

pathway The degree of handicap or heaing loss and which

frequencies

Page 12: AUDIOLOGY IN ORL

12

Crossover Audiometric results are only valid when the

results are actually of the test ear. Interaural attenuation reflects crossover. Air conduction from 40-80dB Bone conduction even at 0dB

Page 13: AUDIOLOGY IN ORL

13

Masking

The audiometric technique used to eliminate responses by the non-test ear.

An appropriate noise is presented to the non-test ear while the test ear is being tested.

Masking level must exceed the non-test ear threshold, but not create crossover.

Page 14: AUDIOLOGY IN ORL

14

Speech Audiometry Determines how well a person hears and

understands speech,subjective test. Spondee words SRT 50% of spondees SRT should be in close correlation with

PTA +- 10 db of PTA. Discrimination score (DS) (90-100% in

normal or conductive DS is 60-70 in sensory hearing loss

Page 15: AUDIOLOGY IN ORL

15

DS -(normal ,CHL, COCHLEAR &RETROCOCH ROLLOVER )

Page 16: AUDIOLOGY IN ORL

16

USES-malingerer patients-for fitting Hearing Aids-for cochlear implant patients-to differentiate cochlear than retro-cochlear lesion

Page 17: AUDIOLOGY IN ORL

17

Acoustic Immittance Impedance: resistance to acoustic

flow,objective test Admittance: ease of acoustic flow Tested by:

Tympanometry Acoustic Stapedial Reflex

Page 18: AUDIOLOGY IN ORL

18

Tympanometryby Jerger

Page 19: AUDIOLOGY IN ORL

19

A normal between 100-(-100) As stiff type otosclerosis or stiff TM. Ad flaccid type ossicular discontinuity B flat –fluid in ME or thick TM C more in negative –retracted TM

Page 20: AUDIOLOGY IN ORL

20

Acoustic Stapedial Reflexto elicit a stapedial muscle

contraction, objective test. 3 primary acoustic reflex

characteristics Presence or absence of the reflex Reflex threshold Reflex Decay It tests VIII,brain stem ,VII Good for screening in infants and

malingerer

Page 21: AUDIOLOGY IN ORL

21

Acoustic Reflex Decay Measures the ability of the stapedius

muscle to maintain sustained contraction.

Lower frequency tone/noise for 10 seconds

Page 22: AUDIOLOGY IN ORL

22

Facial Paralysis Absent or abnormal stapedial reflex

when the recording probe is ipsilateral to the side of the lesion.

Can also be helpful in locating lesions proximal or distal to the stapedial muscle.

Page 23: AUDIOLOGY IN ORL

23

Eighth nerve lesions Absent reflexes when stimuli is

presented to the affected ear. Reflexes in eighth nerve lesions are

not dependent on the degree of hearing loss.

Rapid reflex decay

Page 24: AUDIOLOGY IN ORL

24

Auditory Brainstem Responses

Impulses that are generated by the auditory neural pathway that can be recorded on the scalp.

objective test Not affected by sleep, sedation, or

attention.

Page 25: AUDIOLOGY IN ORL

25

Bone Conduction ABR As reliable and repeatable as air

conduction ABR. Particularly useful in structural

abnormalities Canal Atresia or stenosis

Page 26: AUDIOLOGY IN ORL

26

ABR Primary goal is a clear and reliable

Wave I Wave I : distal 8th nerve Wave II : proximal 8th nerve Wave III : cochlear nuclei Wave IV : SOC Wave V : Lateral Lemniscus

Page 27: AUDIOLOGY IN ORL

27

ABR

Page 28: AUDIOLOGY IN ORL

28

Otoacoustic EmissionsLow energy sounds produced by the

cochlear outer hair cells,objective test.

Cochlear amplification. Spontaneous emissions

Not present in greater than 25dB hearing loss.

Evoked Emissions Transient evoked Distorted Product

Page 29: AUDIOLOGY IN ORL

29

OAE and middle ear pathology

Transmission properties of the middle ear directly influence the OAE characteristics. Otitis media Newborns Tympanic membrane perforations

Page 30: AUDIOLOGY IN ORL

30

ANY QUESIONS