Audiomatica ClioWin 7 – Measurement System. General System Overview System Philosophy System Hardware and Accessories Software Layout Measurement Modules Some Application Examples. Topics. Clio uses a simple audio platform for computer In/Out – PCI Card - PowerPoint PPT Presentation
59
Audiomatica ClioWin 7 – Measurement System
Transcript
Page 1: Audiomatica  ClioWin 7 – Measurement System

Audiomatica ClioWin 7 – Measurement System

Page 2: Audiomatica  ClioWin 7 – Measurement System

Topics

General System Overview System Philosophy System Hardware and Accessories Software Layout Measurement Modules Some Application Examples

Page 3: Audiomatica  ClioWin 7 – Measurement System

Clio Measurement System

Clio uses a simple audio platform for computer In/Out – PCI Card

Calculations are based Computer CPU A signal conditioner is used as a Front-

End with the external world Additional accessories may expand

functions and possibilities

Page 4: Audiomatica  ClioWin 7 – Measurement System

Clio Measurement System

PB-4281 PCI board and SC-01 Signal Conditioner

Page 5: Audiomatica  ClioWin 7 – Measurement System

Clio Measurement System

Page 6: Audiomatica  ClioWin 7 – Measurement System

Clio Accessories

CLIOQC Model 4 Amplifier & SwitchBox

Page 7: Audiomatica  ClioWin 7 – Measurement System

The QCBOX

Page 8: Audiomatica  ClioWin 7 – Measurement System

Clio Measurement System:General Application

Page 9: Audiomatica  ClioWin 7 – Measurement System

Clio Measurement System: Clio + QCBOX Amplifier

Page 10: Audiomatica  ClioWin 7 – Measurement System

Clio Measurement System: QCBOX used as a connection panel

Page 11: Audiomatica  ClioWin 7 – Measurement System

Clio Accessories: The Microphones Mic-01 & Mic-02

Page 12: Audiomatica  ClioWin 7 – Measurement System

Clio Accessories

0 or 20 dBof Gain

A,B,C Weighting Filters Selectable

Page 13: Audiomatica  ClioWin 7 – Measurement System

ClioWin version 7: Calibration Procedure

Page 14: Audiomatica  ClioWin 7 – Measurement System

Clio Measuremen

t System:

Measurement

Precision

Page 15: Audiomatica  ClioWin 7 – Measurement System

Clio Measuremen

t System:

Measurement

Precision

Page 16: Audiomatica  ClioWin 7 – Measurement System

ClioWin version 7 – Software Layout

Page 17: Audiomatica  ClioWin 7 – Measurement System

ClioWin version 7 – Software Layout

Page 18: Audiomatica  ClioWin 7 – Measurement System

ClioWin version 7 – Software Layout

Page 19: Audiomatica  ClioWin 7 – Measurement System

ClioWin version 7 – Software Layout:User selectable options

Page 20: Audiomatica  ClioWin 7 – Measurement System

ClioWin version 7 – Software Layout:External Hardware Interface

Page 21: Audiomatica  ClioWin 7 – Measurement System

ClioWin version 7 – Software Layout:Generator dialog boxes

Page 22: Audiomatica  ClioWin 7 – Measurement System

ClioWin version 7 – Generator

Page 23: Audiomatica  ClioWin 7 – Measurement System

ClioWin version 7 – Software Layout:Measurement Notes

Page 24: Audiomatica  ClioWin 7 – Measurement System

ClioWin version 7 – Software Layout:Graphics & Data Export

Page 25: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Multiple Document Layout

Page 26: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Multiple Document Layout

Page 27: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: MLS & Log Chirp Module

Page 28: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: MLS & Log Chirp Module

Page 29: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: MLS & Log Chirp Module

Page 30: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Cumul. Spectral Decay

Page 31: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Cumul. Spectral Decay

Page 32: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Polar Directivity Map

Page 33: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Polar Analysis

Page 34: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Acoustical Parameters

Page 35: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Acoustical Parameters

Page 36: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: FFT Spectrum + Time Data

Page 37: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: RTA Spectrum Analyzer

Page 38: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: "LIVE" Transfer Function

Page 39: Audiomatica  ClioWin 7 – Measurement System

Sinusoidal Freq. Response + Harmonics

Page 40: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Sinusoidal Impedance

Page 41: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Multi-Meter Module

Page 42: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: T&S Parameters Modules

Page 43: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Wow & Flutter Analysis

Page 44: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Leq Sound Level Analysis

Page 45: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Linearity Analysis

Page 46: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: Distortion Analisys

Page 47: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: QC Capability

Page 48: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: A QC Script

Page 49: Audiomatica  ClioWin 7 – Measurement System

QC: Tolerance masks (Limits)

relative limits

absolute limits

[RELATIVE][UPPER LIMIT DATA]200 5300 210000 215000 5[LOWER LIMIT DATA]200 -5300 -210000 -215000 -5

[ABSOLUTE][UPPER LIMIT DATA]200 100300 9710000 9715000 100[LOWER LIMIT DATA]200 82300 8510000 8515000 82

Page 50: Audiomatica  ClioWin 7 – Measurement System

QC: Sensitivity & Level check

Page 51: Audiomatica  ClioWin 7 – Measurement System

QC: Sensitivity & Level check

level shift

Page 52: Audiomatica  ClioWin 7 – Measurement System

QC: Sensitivity & Level check[RELATIVE][LEVEL]UPPER=3LOWER=-3FREQHI=5000FREQLO=400[UPPER LIMIT DATA]200 5300 210000 215000 5[LOWER LIMIT DATA]200 -5300 -210000 -215000 -5

Page 53: Audiomatica  ClioWin 7 – Measurement System

QC: Sensitivity & Level check[RELATIVE][SENSITIVITY]FREQ1=500FREQ2=1000FREQ3=2000UPPER=102LOWER=100[UPPER LIMIT DATA]200 10500 101000 51500 52000 104000 10[LOWER LIMIT DATA]200 -10500 -101000 -51500 -52000 -104000 -10

Page 54: Audiomatica  ClioWin 7 – Measurement System

QC: T&S parameters check

LIMITS

[TSPARAMETERS]REDC=6.2DIAMETER=110KNOWNMMD=10.7952QTSUPPER=0.6QTSLOWER=0.3FSUPPER=90FSLOWER=50CMSUPPER=1.1CMSLOWER=0.8BLUPPER=6.5BLLOWER=6ZMINUPPER=7.5ZMINLOWER=7

SCRIPT

[SIN]OUT=-2.0IN=0.0REFERENCE=IMPEDANCE.SINILIMITS=IMPEDANCE.LIM

Page 55: Audiomatica  ClioWin 7 – Measurement System

QC: RUB&BUZZ check

LIMITS

[UPPER LIMIT DATA]689.75 82.84793.78 67.80856.99 64.411362.95 65.681693.42 59.961737.23 58.261982.28 62.922223.72 51.692625.30 56.992883.04 48.313462.13 45.553659.12 38.564018.35 40.254283.29 35.384887.50 30.725696.91 35.177292.28 26.0621046.80 22.88

SCRIPT

[FFT]OUT=0.0IN=-10REFERENCE=R&B.FFTLIMITS=R&B.LIM

Page 56: Audiomatica  ClioWin 7 – Measurement System

QC: THD & Harmonics checkLIMITS

[UPPER LIMIT DATA]1000 1062000 1165000 1167000 96[LOWER LIMIT DATA]1000 892000 994000 996000 80[3 UPPER LIMIT DATA]300 70500 902000 905000 70[4 UPPER LIMIT DATA]200 55400 681300 792500 775300 776300 67[THD UPPER LIMIT DATA]200 801000 955300 956300 78

Page 57: Audiomatica  ClioWin 7 – Measurement System

QC: Operator interaction

Page 58: Audiomatica  ClioWin 7 – Measurement System

ClioWin 7: SuggestedHardware & Software Requirements

PentiumII Processor or better1 Free PCI Slot

Microsoft Windows 98, ME, 2000 or XP 1024x768 256 Colors Video or better

Page 59: Audiomatica  ClioWin 7 – Measurement System

Thank you!