AUSSIE SMART PUMPS OWNERS MANUAL
Engine drive, electric drive,
hydraulic drive, bare shaft Revision: #2 (Oct 18)
Australian Pump Industries
IMPORTANT To reduce the risk of injury, read operating instructions carefully before using equipment
Aussie Smart Pump… Owners Manual 2
Australian Pump Industries Oct 2018
Australian Pump has developed a
reputation for innovation and quality that
has lead to a rapid market acceptance
both in Australia and throughout the
world. Aussie Pump products are used
in Europe, United States, throughout
South East Asia and the Pacific region.
Our rapid growth is based on five simple
principles.
Performance
A genuine dedication to deliver
products that out perform and out
feature all others, leading to better
outcomes for users.
Quality
A relentless drive for quality that
delivers lower through life costs and
improved ecological outcomes
Value
A pricing policy that delivers excellent
products at fair prices.
Prompt Delivery
A commitment to build and deliver on
time
After Market Support
To provide through life support
through well trained, professional and
motivated distribution team both in
Australia and throughout the World.
Before using the pump it vital to
ensure the materials of
construction for the pump and
seals are chemically compatible
with the liquid to be pumped!
Check the model code …
RSE … polyester body
RSP … polypropylene body
Do not use a pump that is not
chemically compatible with the
liquid you intend to pump.
Serious injury, death or
environmental damage could
result.
If uncertain contact your Aussie
dealer for the Corrosion Resistance
Charts.
Aussie Pumps … Reliable Products, Reliable People
SAFETY WARNING
Aussie Smart Pump… Owners Manual 3
Australian Pump Industries Oct 2018
Table of Contents ................. 3 Product specifications ........... 3 Warranty terms .................... 4 Safety Precautions ................. 6
Pump Preparation ................ 9 Pump Operation ................. 11 Troubleshooting ................. 12 Exploded view & parts list ... 14
TABLE OF CONTENTS
Keep this owner’s manual handy so you can refer to it at any time. The Aussie Pump Owner’s manual is considered a permanent part of the pump and should remain with it if resold. The information and specifications
included in this publication were valid at the time of printing however, Australian Pump Industries reserves the right to discontinue or change the specifications or design any time without notice and without incurring any obligation.
PRODUCT SPECIFICATIONS
(Recommendation only - check compatibility chart for specifics)
1. For oil based liquids including diesel fuel, select BUNA elastomer option
2. For most ag. chem. liquids select EPDM elastomers
3. Viton elastomers available. For chemical compatibility check 'Chemical
Compatibility Chart'
Polyester body Engine drive Electric
drive Hydraulic
drive
Inlet/Outlet
Impeller EPDM Buna N Viton Max Flow
Max Head
Max Flow
Max Head
Max Flow
Max Head
2” 706 high head RSE2BUL RSE2BUB RSE2BUV 720 37 580 22.5 720 37
2” 975 high flow RSE2BRL RSE2BRB RSE2BRV 835 25 660 16 835 25
3” 706 high head RSE3BXL RSE3BXB RSE3BXV 870 37 700 22.5 870 37
3” 975 high flow RSE3BSL RSE3BSB RSE3BSV 1010 25 800 16 1010 25
Polypropylene body Engine drive Electric drive Hydraulic
drive
Inlet/Outlet
Impeller Viton Max Flow
Max Head
Max Flow
Max Head
Max Flow
Max Head
2” 975 high flow RSPRY2BRV 835 25 660 16 835 25
Flow in lpm, heads in metres
Aussie Smart Pump… Owners Manual 4
Australian Pump Industries Oct 2018
WARRANTY TERMS
Aussie poly pump warranty
Australian Pump warrants that all
Aussie poly pump self priming
centrifugal pumps, whether used for
domestic or commercial applications,
are warranted to be free of faulty
workmanship or material for a period of
five years from the date of supply to the
end user.
Note:- This warranty is limited
to the cost of the product and
does not include third party
costs including pump installers,
plumbers etc. unless expressly
authorised by Australian Pump
Industries in writing.
Engine Warranty
Warranty for engines fitted to Aussie
Pump products is the responsibility of
the engine manufacturer or his
representative. As such, it is subject to
the particular manufacturer’s stated
guarantee, terms and conditions, and
operating instructions included with the
product.
The warranty is valid only for the
original consumer purchaser. Warranty
is not automatically transferred if the
goods are sold on as second hand
items.
Aussie Pump warranty does not
cover the following:-
1. Normal wear and tear.
2. Damage generated by removal
or installation of the product.
3. Incorrect installation of product.
4. Misuse or misapplication of
product.
5. Excessive pressure (in excess
of 50 psi) due to hydraulic
shock.
6. Incompatibility between the
pump material of construction
and the liquid being pumped.
7. Damage to ports due to
overtightening.
8. Unauthorised repair or
attempted repair (i.e. not
authorised by Australian Pump).
Aussie Smart Pump… Owners Manual 5
Australian Pump Industries Oct 2018
9. Shipping or transit damage
10. Use of non-genuine parts.
Our goods come with guarantees that
cannot be excluded under the
Australian Consumer Law. You are
entitled to a replacement or refund for
a major failure and for compensation
for any other reasonably foreseeable
loss or damage. You are also entitled
to have the goods repaired or
replaced if the goods fail to be of
acceptable quality and the failure does
not amount to a major failure.
Warranty Claims
When claiming warranty, consumers
must give evidence to the local Aussie
Pump service station of date of
purchase, model and serial number of
the product, and the claimant’s name,
address and telephone number.
To claim warranty, you will need to
provide the following data:-
1. Written confirmation of the
nature of your claim.
2. Proof of purchase.
3. Where necessary, full
installation data, including
installation design drawings
where appropriate.
WARRANTY TERMS
4. The product must be forwarded
freight pre-paid to Australian
Pump with prior written approval.
Costs generated by a service call from
an authorised Aussie Pump service
agent will incur a travel, removal and re
-installation fee if the service agent is
required to judge warranty issues.
In the event that the product is not
readily accessible for inspection,
warranty service will be denied or
suspended pending availability of the
whole item.
Warranty will be denied if product is
found to have been abused, misused,
or improperly installed.
Any unauthorized modification to the
equipment will automatically void
warranty.
Aussie Smart Pump… Owners Manual 6
Australian Pump Industries Oct 2018
Before starting the pump read Pump Operators manual.
Please note that the pump operator’s manual does not include detailed engine data. Check the engine manual, supplied with the product, for further information.
Never use these pumps for pumping flammable liquids such as petrol. AN EXPLOSION & SERIOUS INJURY
may result if this waring is ignored.
If pumping corrosive or hazardous materials, extreme caution should be used. Provide safety guards, ventilation and drains to protect people and property in case of a leak in the pump. Follow handling instructions from the manufacturers
of the liquid.
Engine powered pumps
No oil is supplied with the engine. Oil must be added in accordance with the engine manufacturer’s instructions. (Relevant to four stroke engines only).
Do not use the pump in an enclosed area, engine exhaust could build up and cause asphyxiation.
Do not refuel engine while operating. Shut engine down and allow to cool before refueling.
Always refuel in a well ventilated area, do not smoke or allow flames or sparks in the refueling area or where gasoline is stored.
Do not over fill the fuel tank, as spilled fuel can ignite if it comes into contact with hot engine parts or sparks. After refueling, make sure tank cap is closed properly and is secure.
Some engine components will get hot during operation. Do not touch engine components while engine is running or immediately after operation. For details check engine operator’s manual.
All versions
Do not use the pump in a gaseous or hazardous environment or near combustible material.
Any person operating the pump and its power unit should be fully aware of tits safe operation before starting
the unit.
Ensure pump is on secure footing so that it can not move
or tip over.
Before carrying out maintenance on the pump, endure that the power has
been disconnected
SAFETY PRECAUTIONS
Aussie Smart Pump… Owners Manual 7
Australian Pump Industries Oct 2018
Pump must be primed before starting. Fill pump body with liquid. Pump must not be allowed to run without liquid passing through the casing.
DO NOT run pump either dry or with insufficient water supply. Pump supply or delivery lines must not be shut off.
Familiarise yourself with the pump’s controls with emphasis on how to stop the pump quickly.
Ensure that the power unit, pump, wiring and piping installations are suitable for the liquid being pumps. Comply with all applicable codes and regulations.
Do not use torches or apply fire or flames to the pumps for any reason.
This pump must not be subjected to more that 65 psi for polyester pumps, 55 psi for polypropylene pumps.
Do not …
Over speed the engine
Use quick closing valves in suction or discharge line or any other device that can cause hydraulic shock.
Use high positive suction pressures which would cause the total system pressure to 65 psi or above (55 psi for polypropylene pumps)
Protect your pump from pressure spikes by installing a by-pass or safety valve if sudden shut off of the water flow is likely to occur.
Drain pump if there is a chance of the liquid freezing inside the pump body or connecting pipework.
Do not pump liquids with specific gravities exceeding the following values.
Do not over tighten the drain or filler plugs. Hand tighten only. Excessive force may damage the threads or the pump body. Do not use metal plugs.
Use at least one foot of flexible hose to make plumbing connections to the pump body. Rigid piping may put stresses on the pump causing damage. If rigid piping must be used, properly support it so as to eliminate stresses to the pump.
Max specific gravity at 3450 rpm
Impeller Polyester Polypropylene
706 1.2 1.0
975 1.8 1.5
SAFETY PRECAUTIONS
Aussie Smart Pump… Owners Manual 8
Australian Pump Industries Oct 2018
Do not tighten inlet & discharge fitting more than one turn beyond hand tight. Excessive force will damage the fitting. Use Teflon sealing tape on all threaded fittings.
Long suction and discharge hoses or pipes must be supported so the weight of the hoses or pipes filled with liquid do
Use only genuine replacement
parts.
Always fill the pump body with the liquid to be pumped before starting the pump. It is not necessary to drain the pump body after use, unless there is danger of freezing, settling of solids or crystallisation.
Do not restrict the flow through the pump. A starved suction line can cause heat to build up. If it is necessary to restrict flow through the pump for longer than five minutes install a discharge bypass line to keep the liquid below maximum operating temperatures.
Do not subject pump to extreme conditions of acidity or basicity. Consult factory for specific recommendations concerning chemicals and temperature.
DO NOT OPEN THE PUMP
WHEN OPERATING!
SAFETY PRECAUTIONS
Aussie Smart Pump… Owners Manual 9
Australian Pump Industries Oct 2018
Inspect unit for shipping damage immediately upon receipt and before signing for merchandise. If any visible damage exists, note damage on shipping documents before signing. Also notify you dealer immediately of any damage
to the shipment.
Engine Drive Pumps
Consult engine manual included with pump.
Before starting, fill crankcase with oil as specified by the engine manufacturer.
Fill fuel tank with clean, fresh, fuel as specified in engine manual.
Electric Motor Pumps
Ensure the power suppled to the electric motor matches the motor specification plate.
Ensure the motor rotation is correct. The pump impeller should rotate counterclockwise, looking from the suction inlet side. For single phase motors consult the wiring diagram for anticlockwise rotation. Three phase motor rotation may be reversed by interchanging any two of the three power leads.
Make sure that wiring for the electric motor compiles with all existing codes.
Hydraulic Drive Pumps
Consult the separate instruction sheet supplied with each hydraulic powered unit.
Power Requirements
NOTE: for liquids having specific gravities greater than 1.0, increase the rated horsepower (from catalogue) by a factor equal to the specific gravity of the liquid being pumped. (E.G. Catalogue HP x Specific gravity = actual HP required)
PUMP INSTALLATION
When installing an Aussie self priming pump always remember that the closer the pump is placed to the source of supply the better the performance will be.
To ensure maximum capacity select a site that will permit the shortest and most direct suction piping and smallest vertical lift.
Set the pump on firm and level foundations.
Connecting the Suction Hose
Use commercially available hose, hose connector and hose bands. The suction hose must be of reinforced non collapsible construction.
PUMP PREPARATION
Aussie Smart Pump… Owners Manual 10
Australian Pump Industries Oct 2018
Suction hose length should not be longer than necessary as the longer the suction hose, the less delivery performance of the pump.
Self priming time is also proportional to suction hose length!
A strainer should always be used on the end of the suction hose to keep solids out of the pump.
If the strainer is likely to clog with dirt or debris, do one of the following…
1. Prepare a bed of rocks on which to rest the strainer.
2. Tie strainer so that it stays off the bottom of the pit.
3. Tie the strainer inside a basket or pail.
Check carefully to make sure there
are no air leaks in the suction line.
Connecting the Discharge Hose
Use a commercially available hose, hose connector and hose bands.
A large diameter hose is most efficient. Long, small diameter hoses will increase friction loss and reduce pump performance and adversely affect performance.
Check carefully to make sure there
are no leaks in the discharge line.
PUMP PREPARATION
Aussie Smart Pump… Owners Manual 11
Australian Pump Industries Oct 2018
PUMP OPERATION
Priming
Remove the priming cap at the top of the delivery port. Fill pump body with water and refit priming cap tightly.
Open gate valve on delivery line if fitted.
Never attempt to operate pump without priming first. Extended dry operation will destroy pump seal.
If unit has been operated dry, stop the engine immediately, allow the pump to cool before adding priming liquid.
Hydraulic Shock
If the water flow is suddenly terminated by closing a valve, without stopping the pump first, it can cause hydraulic shock. This can travel back to the pump causing serious damage. To prevent pump damage install a by-pass or safety valve.
Handy service hints
1. To maximize pump life, drain pump after use and flush out with clean, fresh water.
2. Store pump in a dry, safe location when not in use.
3. If storing for long periods, drain fuel from engine and tank.
4. If there is a risk of freezing drain the pump body
5. Before pumping chemicals check suitability of seals. For oil based liquids including diesel fuel, select BUNA elastomer option. For most ag. chem. liquids select EPDM elastomers. Viton elastomers are also available for corrosive applications. For further information regarding chemical compatibility contact your Aussie dealer.
6. Pumping water containing solids will prematurely wear pump components, and may impact warranty.
7. Ensure that the correct size strainer is installed on the suction hose at all times.
Aussie Smart Pump… Owners Manual 12
Australian Pump Industries Oct 2018
Engine Troubleshooting; refer to engine manufacturer’s manual
TROUBLESHOOTING
Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of an issue check the Troubleshooting information shown below.
PUMP TROUBLESHOOTING
SYMPTOM POSSIBLE PROBLEM SOLUTION
Pump does not prime.
Not enough priming liquid in the housing?
Add more priming liquid.
Engine speed too low? Increase throttle.
Strainer plugged? Clean strainer
Suction hose damaged? Replace or repair hose, and clamps
Air leak at suction port? Check that fittings are tight and properly sealed.
Pump is located too high above water line?
Move pump closer to water.
Debris collecting in pump housing?
Clean pump housing.
Too much distance between impeller and volute.
Adjust clearance by adding shims or replace impeller. Min. .010" -Max. .020
Water leaking out weep hole between pump and engine?
Check condition of mechanical seal and gaskets, between pump end and engine housing.
Suction lift or discharge head too high.
Check hose/pipe installation.
Pump takes in liquid but little or no discharge.
Engine speed too low? Increase throttle speed
Impeller rotating in wrong direction Check wiring on motor
Suction strainer partially plugged? Clean strainer
Impeller/volute worn? Adjust clearance by adding shims or replace impeller/volute
Suction hose leaks at inlet
Fittings/clamps are not sealed properly?
Tighten, replace or add clamp. (Keep extra seals on pump)
Hose diameter is too large? Use smaller diameter hose or replace hose
Discharge hose does not stay on coupling.
Pressure too high? Check pressure, add additional clamp.
Hose kinked or end blocked? Check hose.
Impeller does not turn, pump is hard to start.
Impeller jammed or blocked? Open pump cover and clean dirt and debris from inside housing.
Impeller and volute binding? Adjust clearance by removing shim from behind impeller.
Defective engine? See Engine Owners Manual.
Aussie Smart Pump… Owners Manual 14
Australian Pump Industries Oct 2018
EXPLODED VIEW & PARTS LIST
Ref # Polyester Description Quantity Polypropylene
4 58.0721.10 NUTS 10 58.0721.10
6 58.0703.30 BACK CASING (BRACKET) 1 58.0703.40
7 58.0719.71 O-RING BODY BUNA N 1 58.0719.71
7 58.0719.72 O-RING BODY EPDM 1 58.0719.72
7 58.0719.73 O-RING BODY VITON 1 58.0719.73
8 58.0717.71 O-RING SCREW BUNA-N 5 58.0717.71
8 58.0717.72 O-RING SCREW EPDM 5 58.0717.72
8 58.0717.73 O-RING SCREW VITON 5 58.0717.73
9 58.0715.10 SCREW BRACKET 5/16 – 24 X 1.25 4 58.0715.10
10 58.0754.71 O-RING SEG BUNA N 1 58.0754.71
10 58.0754.72 O-RING SEG EPDM 1 58.0754.72
10 58.0754.73 O-RING SEG VITON 1 1 58.0754.73
11 58.0976.71 O-RING SHAFT SEAL BUNA N 1 58.0976.71
11 58.0976.72 O-RING SHAFT SEAL EPDM 1 58.0976.72
11 58.0976.73 O-RING SHAFT SEAL VITON 1 58.0976.73
12 58.0750.40 SCREW PLUG 1 58.0750.40
Aussie Smart Pump… Owners Manual 15
Australian Pump Industries Oct 2018
Ref # Polyester Polypropylene Description Quantity
13-14 58.0714.11 58.0714.11 SHAFT SEAL BUNA N 316SS CARBON CERAMIC 1
13-14 58.0714.12 58.0714.12 SHAFT SEAL EPDM 316SS CARBON CERAMIC 1
13-14 58.0714.14 58.0714.14 SHAFT SEAL VITON 316SS CARBON CERAMIC 1
15 58.0975.30 58.0975.40 IMPELLER HIGH VOLUME 4 VANE 975 1
15 58.0706.30 58.0706.40 IMPELLER HIGH HEAD 5 VANE 706 1
16 58.0716.10 58.0716.10 SCREW IMPELLER SS 1
17 58.0977.30 58.0977.40 VOLUTE HIGH VOLUME (975) 1
17 58.0702.30 58.0702.40 VOLUTE HIGH HEAD (706) 1
18 58.0725.10 58.0725.10 SCREW SIDE VOLUTE SS 2
19 58.0771.10 58.0771.10 SCREW TOP VOLUTE SS 1
20 58.0705.71 58.0705.71 CHECK VALVE - BUNA N 1
20 58.0705.72 58.0705.72 CHECK VALVE - EPDM 1
20 58.0705.73 58.0705.73 CHECK VALVE - VITON 1
21 58.0720.10 58.0720.10 SCREW BODY STAINLESS STEEL 10
22 58.1009.71 58.1009.71 O-RING DRAIN PLUG BUNA 1
22 58.1009.72 58.1009.72 O-RING DRAIN PLUG EPDM 1
22 58.1009.73 58.1009.73 O-RING DRAIN PLUG VITON 1
23 58.0723.30 58.0723.40 DRAIN PLUG 1
24 58.0722.30B 58.0722.40 FILLER PLUG 1
25 58.0765.71 58.0765.71 O-RING FILLER PLUG - BUNA 1
25 58.0765.72 58.0765.72 O-RING FILLER PLUG - EPDM 1
25 58.0765.73 58.0765.73 O-RING FILLER PLUG - VITON 1
27 58.0718.10 58.0718.10 KEY 316SS 1
30 58.0778.11 58.0778.11 SHIM .006 SS As req
42 58.0784.30B 58.0784.40 FRONT CASING 2" 1
42a 58.0877.30B 58.0877.40 FRONT CASING 3" 1
46 58.0882.90 58.0882.90 SHAFT SLEEVE 1
56 58.0001 58.0001 PLASTIC PEDESTAL KIT - CARBON STEEL SHAFT
1
56a 58.0012 58.0012 PLASTIC PEDESTAL KIT - STAINLESS STEEL SHAFT
1
56b RKIT097 RKIT097 CAST IRON PEDESTAL KIT - STAINLESS STEEL SHAFT
1
68 58.1367.30 58.1367.40 DELVERY ELBOW 2" BSP 1
68 58.1368.30 58.1368.40 DELIVERY ELBOW 3" BSP 1
S2 & S3 58.0014 58.0014 BUNA N CONVERSION KIT 0
S2 & S3 58.0005 58.0005 EPDM CONVERSION KIT 0
S2 & S3 58.0017 58.0017 VITON CONVERSION KIT 0
EXPLODED VIEW & PARTS LIST
Australian Pump Industries Pty Ltd
7 Gladstone Road, Castle Hill NSW 2154 Ph: (02) 8865 3500 Fax: (02) 9894 4240
www.aussiepumps.com.au [email protected]
Reliable Products … Reliable People
Value packed products
Great Service
Delivered on time
Other pumps available from Aussie Pumps...
Aussie QP water transfer & fire pumps
Aussie GMP Industrial pumps
Aussie diaphragm pumps