    here has been a growing understanding of the microbial threatsT that exist in laboratory & medical practice as of today.Simultaneously these threatening trends have been accompanied by atremendous advance in the science and technology of in-clinicsterilization.

    All Medical Professionals must possess a good basic knowledgeabout the process of sterilization as otherwise their patients' as well astheir staff & their own health & lives are at risk.

    So what exactly is sterilization?

    Sterilization is the destruction or removal ofall viable microorganisms, including many ofthe resistant bacterial spores. Since this

    process covers the broad range of pathogensthat may be found in dental, ophthalmic & anysurgical procedure, it is the only clinicallyacceptable means for dealing with reusableinstruments between patients.

    In order to understand "Why Class BAutoclave?", let us first understand how aSteam Pressure Steriliser - commonly knownas an Autoclave - sterilizes.

    Autoclaves commonly sterilize by exposingits charge (items to be sterilized) to elevatedtemperatures of 121 to 134C under pressureof 15 to 30 psi, for a holding time of anywhere

    between three to 30 minutes. Please note that the three to thirtyminutes time is the holding time at the set elevated temperature & notthe total process or cycle time. Total cycle time would be far greater.The combination of the three lethal parameters of time, temperatureand steam, deliver a powerful kill rate which even the hardiest of

    bacteria find hard to survive. This effective & yet clean method oflethality is unmatched by any of the other methods of sterilisation.

    Saturated steam at this temperature is an excellent carrier of heat. Theoperative word is saturated steam. The steam condenses onto itscharge and as it does so it not only expends its huge latent heat butalso draws in additional steam to replace the condensed steam. Thusthe heat transfer is very efficient and the penetration levels extremelyhigh.

    However, if there is residual air in the chamber and load, it willinterfere with steam-instrument contact, and may compromisesterilization. This residual air can prevent penetration of steam to thedepths of the load, leaving your sterilisation incomplete. Why & how

    would this happen? When you load the Autoclave with instrumentsand close the lid, there is already a lot of stale air trapped inside. Forsterilisation to take place, this air needs to be effectively purged andreplaced with saturated steam.

    To resolve this problem of purging entrapped air, normal Autoclaveswill have a manual, mechanical or electrically operated valve opentill about 100C. Once it is closed the pressure & temperature beginsto rise. It is presumed that by this time, the entire entrapped inner airhas been purged. However, tests have shown that this is not aneffective method for vials, wrapped items, implants, garments andcertain types of hollow ware. You can never be assured of efficient

    penetration of steam right inside, if you are using a regular Autoclave.Even a small volume of entrapped air can compromise your sterilityassurance level simply because ordinary entrapped air is a very bad

    conductor of heat & moisture. These pockets of air cannot conductheat to the load with the same vigor as steam and therefore cold spotsremain within the load.

    The type N-cycle is suitable for sterilizing only unwrapped and solidinstruments. N-cycle sterilizers are the most popular bench topautoclaves (top or front loading), and are classified as passivesystems (also known as gravity or non-vacuum). Typically, as steamis generated or admitted into the sterilization chamber, it forces

    unsaturated and saturated air out through a vent. The major concernwith the N-cycle sterilizers is the non-removal of trapped air(especially air pockets in lumens and difficult-to-access areas of theload) during displacement.

    Errors in packaging oroverloading the sterilizerchamber can result in cool air

    pockets where items are notsterilized.

    The type B sterilisation cycleis used to process loads thatcan retain air. It can sterilizesolid, hollow, and porous

    instruments, be they wrappedor unwrapped. Pressurizeds t eam i s an e f fec t ivesterilizing agent providedthatthe internal air has first beenremoved from the chamber aswell as the air retentive load.Residual air prevents directcontact between steam & the

    load to be sterilised. Hence this B-cycle involves the use of active(forced) air removal, usually by using an inbuilt vacuum pump. These

    pre vacuum or Class-B sterilizers create a vacuum, thus removing airfrom the load prior to the chamber being pressurized with steam. Thiscan be done from 1 to 3 times - depending on the cycle selected. This

    technique allows faster and more effective steam penetrationthroughout the entire instrument load than the gravity displacementtechnique typically employed in sterilizers with N-cycles.

    A typical cycle of a Class B Sterilizer:

    A Class-B Autoclave is essential if you are:! Pouching your instruments! Double wrapping your instruments! Sterilising lumens, implants or instruments that have difficult to

    access areas! Sterilising porous loads like garments, gowns, dressings

    sterilizing! Hollow ware of Type A Sterilising Vials

    ChamberPressure(mbar)

    VAC Pre-Vacuum Sterilize Exhaust Post Vacuum& Drying

    AutomaticAeration

    2200

    2000

    1800

    1600

    1400

    1200

    1000

    800

    600

    400

    200

    0

    MEDICA INSTRUMENT MFG. CO.105, Vasan Udyog Bhavan, Sun Mill Compound, Lower Parel (West), Mumbai 400013, INDIA

    Tel: +91-22/6618-9999 Fax: +91-22/6618-9996 e-mail: [email protected] www.medicainstrument.com

    Why CLASS-B Autoclave?Why CLASS-B Autoclave?

  • 8/8/2019 Auto Why Class-B + HCL

    2/5

    EQUITRON

    R

    Sterilizing Temperature

    Test

    Safety Features

    Water supply system

    Voltage

    Power

    121C or 134C

    Bowie & Dick test

    Pressure Release Valve and computerized diagnosing and alarm system

    Reservoirs (2Ltr fresh water supply system and 1.6Ltr waste water reservoirs)

    220V10% 50/60Hz, single phase

    2400W / 10A

    Techical Specifications:

    All electrical appliances work on 230V AC, 50Hz, single phase. Other Voltages available on request.Due to continuous improvement in design, the product supplied may have modified features.

    Applications:

    EQUITRON Advantages:

    Construction / Standard Features:

    v

    v

    v

    v

    v

    v

    v

    v

    v

    EQUITRONTable Top Vacuum High Speed Sterilizersare ideal for all applications requiring rapid, reliable andtotal destruction of all living microorganisms.

    Ideal for Ophthalmic Surgeons, Dental Surgeons,Surgical Doctors, Polyclinics and Hospitals, Operationtheatres, QC / Micro as a stand-by unit.

    It adopts European Class B standard.

    With pulse pre-vacuum - essential for sterilizing allwrapped (single / double) or unwrapped items, includingporous items that do not exceed the specifications ofHollow load Type A.

    A pre defined program list for easy operational settings:Reproducible sterilization cycles are accomplishedthrough the defined programs.

    Electronic control module offers microprocessorcontrols and LED display of operating parameters,where temperature, pressure and sterilisation time are constantly displayed.

    A drying cycle helps prevent rusting of delicate instruments and helps dry clothing orabsorbent materials.

    Safer and more reliable door structure. A heat-insulated door with locking feature preventsopening while the chamber is under pressure to help minimize dangers to operator.

    Exhaust steam is discharged to an inbuilt water collection tank thus keeping the roomsteam free.

    For zero infections....

    CLASS-B TABLE TOP AUTOCLAVES

    0061_

    0906-0-1

    #7471-B-22

    Model Product TraysChamber Size Heater (W)App. Shipping Details

    (Air)Net / Gr. / Volume

    EQUITRON

    Class - B

    Autoclave

    250mm x 450mm(22L approx.) 3

    1500 Band heater

    750 for Steam generator45 kg / 72 kg / 0.35m#7471-B-22 450 x 650 + 150 x 400

    External DimensionW/D/H in mm

  • 8/8/2019 Auto Why Class-B + HCL

    3/5

    EQUITRONAdvantages:

    Construction:

    Standard Features:

    v

    v

    v

    v

    v

    v

    v

    v

    v

    v

    v

    Compact ergonomic design with fully automatic flash cycle

    without drying.Requires a sterilizing time of just 7 minutes at 134C

    (instead of 20 minutes at 121C).A totally hassle and tension free sterilizer which can even be

    kept inside an operation theatre.Results reproducible because full cycle is automatic,

    requiring no human intervention.

    All wetted parts are of SS.Single lever pronged closure system with patented Silicone

    Gasket (registered design No. 208774.)

    P Controller with following parameters programmable by

    user: Sterilizer Time: up to 99 minutes. Sterilizing

    Temperature: up to 134C.Pt100 Sensor for precise monitoring.End cycle buzzer and auto reset.Water filing with manual operated valve.Industrial Grade energy efficient heater.

    TABLE TOP STERILIZER

    TABLE TOP STERILIZER with drying

    All elect rica l ap pliance s work on 230 VAC, 50Hz, single pha se.Due to continuous improvement in design, the product supplied may have modified features.

    R

    All electrica l ap plianc es work on 230 VAC, 50Hz, single pha se.Due to continuous improvement in design, the product supplied may have modified features.

    #7470-11

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

    EQUITRONAdvantages:

    Construction:

    Standard Features:

    v

    v

    v

    v

    v

    v

    v

    v

    v

    v

    v

    v

    Sterilizing, exhaust of water and steam drying are fullyautomatic.Requires a sterilizing time of just 7 minutes at 134C (instead of

    20 minutes at 121C).A totally hassle and tension free sterilizer which can even bekept inside an operation theatre.Results reproducible because full cycle is automatic, requiringno human intervention.

    Full stainless steel construction.Single lever pronged closure system with patented SiliconeGasket (registered design No. 208774.)

    P Controller with following parameters programmable byuser: Sterilizer Time: up to 99 minutes. SterilizingTemperature: up to 134C. Drying time: up to 99 minutes.Pt100 Sensor for precise monitoring.End cycle buzzer and auto reset.Valves for water filing and exhaust.Industrial Grade energy efficient heater.Drying with door open facility.

    #7471-16

    Safety:v

    v

    v

    Sensor open alarm and over temperature protection.Pressure interlock on door.Spring loaded safety valve for over pressure.

    Safety:v

    v

    v

    Sensor open alarm and over temperature protection.Pressure interlock on door.Spring loaded safety valve for over pressure.

    105, Vasan Udyog Bhavan, Sun Mill Compound, Lower Parel (West)Mumbai 400013, INDIA ' +91-22/6618-9999 , +91-22/6618-9996) [email protected] www.medicainstrument.com

    #7471-16 350 kg / 65 kg / 0.3 m

    ModelApp. Shipping Details (Air)

    Net / Gr / Volume

    230 x 400 mm (16 lit) 560 x 500+125 x 450 2 trays 1.2 kW

    Chamber Size Tray HeaterExternal Dimension

    W/D/H in mm

    #7470-16 340 kg / 55 kg / 0.16 m

    ModelApp. Shipping Details (Air)

    Net / Gr / Volume

    200 x 500 mm (16 lit) 3 trays

    Chamber Size Tray Heater

    #7470-11 335 kg / 50 kg / 0.12 m 200 x 350 mm (11 lit) 450 x 460+125 x 385

    450 x 610+125 x 385

    1.2 kW

    1.2 kW

    3 trays

    External DimensionW/D/H in mm

    0061_

    0906-0-2

  • 8/8/2019 Auto Why Class-B + HCL

    4/5

    R

    EQUITRON

    EQUITRON Advantages:

    Construction / Standard Features:

    v

    v

    v

    v

    v

    v

    v

    v

    Hasslefree - preset automatic with digital display (121C / 20 min) - with auto switch off.

    Can be safely kept in air conditioned clinics.Low power consumption. Just 0.6 units for #7701PAD & 0.8 units for #7407PAD percycle.

    The total sterilization process takes just around 40 minutes from start to finish.

    Results reproducible because purging is automatic, while temperature and time arefactory preset and electronically controlled.

    Die pressed seamless body, lid & heater cover stand of stainless steel.

    Simple and easy Press and turn system of closing lid for #7407PAD & flynutassembly for #7701PAD.

    Supplied with Stainless Steel Dressing Drum and heater cover stand.# 7407PAD

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

    MINI & PORTABLE AUTOCLAVEPreset Automatic Digital (PAD)

    # 7407PAD

    # 7701PAD

    30 x 23 cm (12 x 9") / 16 Ltr.

    20 x 18 cm (8 x 7) / 6 Ltr.

    39.0 kg / 11.0 kg / 0.11 m

    39.0 kg / 11.0 kg / 0.08 m

    1.8 kW

    1.2 kW

    27 x 22 cm (11 x 9")

    Model Working ChamberSize ( x D) / Ltr.Dressing Drum Heater App. Shipping Details

    Net / Gr. / Volume

    17 x 17 cm (7 x 7)with seperator & mat

    0061_

    0906-0-3

    Product

    Dental Casset - A30

    Dental Casset - B25

    Dental Casset - B45

    Dental Casset - C25

    Dental Casset - C45

    Size

    175 x 55 x 30mm app

    175 x 85 x 25mm app.

    175 x 85 x 45mm app.

    175 x 150 x 25mm app.

    175 x 150 x 45mm app.

    Model

    #6281-A30

    #6281-B25

    #6281-B45

    #6281-C25

    #6281-C45

    All electrical appliances work on 230V AC, 50Hz, single phase. Other Voltages available on request.Due to continuous improvement in design, the product supplied may have modified features.

    #8105-12

    EQUITRON Applications & Advantages:

    v

    v

    v

    v

    v

    Ideal for safe keeping of sterilised items.

    Powerful ultra violet tubelight with wavelength of 253.7nm.

    12 stainless steel trays of app dimension 260 x 190 x 12mm ht.

    Safety interlock on the cabinet door protects the user from accidental exposureto UV light.

    Option of wall mounting.

    UV STERILISATION CABINET

    Model Product External Dim (Net) L/B/H in cm

    #8105-12 UV Sterilisation Cabinet 34 x 30 x 67

    17 x 17 cm (7 x 7),

    #S-0082-05

    for #7701PAD

    DRESSING DRUM

    with separator & mat:

    DRESSING DRUM - RECTANGLE:

    17 x 15 (H) x 37cm, #S0083-40

    for #7471-B-22

    DRESSING DRUM:

    27 x 22 cm (11 x 9"),

    #S0082-15

    for #7407PAD

    DENTAL CASSETTE

  • 8/8/2019 Auto Why Class-B + HCL

    5/5

    R

    EQUITRON Advantages:

    Construction:

    v

    v

    v

    v

    v

    v

    v

    Electronic Timer.

    Compact moulded hygienic body with preset switchable heater.

    Frequency 42kHz / 170W. Heating power 80W.

    5 steps digital timer 90S - 180S - 280S - 380S - 480S.

    Strong plastic housing: Better water-proof and drip-proof ability than metal.

    Radiator Fan: To enable continuous operation.

    With moulded base tray & removable transparent lid.

    MEDICA INSTRUMENT MFG CO. .

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

    DIGITAL ULTRASONIC CLEANER

    Model ProductApp. Shipping Details

    Net / Gr. / Volume3

    2.5 kg / 3.5 kg / 0.020 m

    31.0 kg / 1.5 kg / 0.005 m

    Tank Size (Cap)

    24x14x10cm (2.5L)

    5 bottles of 100 ml

    Dig. U/S Cleaner 2.5L#8425.025.42H

    #S1102-05 Deconex-12, Soap Concentrate

    OPTIONAL CONSUMABLES FOR ABOVE

    EQUITRON

    EQUITRON

    #8425.025.42H

    Base tray Transparent lid

    #8425.025.42H

    105, Vasan Udyog Bhavan, Sun Mill Compound, Lower Parel (West)Mumbai 400013, INDIA ' +91-22/6618-9999 , +91-22/6618-9996) [email protected] www.medicainstrument.com

    #7427PAD

    VERTICAL JACKETED AUTOCLAVE - PADPreset Auto ma tic Dig ita l

    EQUITRON Advantages:

    Construction:

    v

    v

    v

    v

    v

    v

    v

    Supplied with traceable certificate for Pressure Gauge and Temperature Indicator.Low water level cut off.

    A sturdy and tension free Autoclave which can safely be operated repeatedly even in remote places.

    Inside chamber, jacket & outer chamber are fully stainless steel.Hydraulically die pressed lid from stainless steel plate.Flanges, fly screws, cross pins are also fully stainless steel.

    All internal joints argon welded, ground and polished to give crevice free internals.

    Standard Features:Electronics & Electricall Digital Temperature Indicator Controller having

    a preset temperature of 121C linked to apreset timer of 20 minutes.

    l End of cycle buzzer.l Industrial grade energy efficient heater(s).

    Mechanicall Lid is fitted with pressure gauge, safety valve and

    extra safety cum manual exhaust valve.l Moulded rubber gasket.l Automatic purging by mechanical valve for efficient

    sterilisation.l Water level indicator.l Fitted with a Safety Valve for added safety.

    Model Heater Working Chamber

    Size ( x D)Capacity

    litersOPTIONAL

    Carrier ( x D) in cmApp. Shipping Details

    Net / Gr. / Volume

    #7427PAD

    #7447PAD

    30 x 50 cm (12 x 20")

    40 x 60 cm (16 x 24")

    35

    75

    3 kW4 kW

    1 of 25 x 45 - #S3084

    1 of 35 x 55 - #S3087

    45 kg / 80 kg / 0.5

    / / 1.0

    3

    m3

    80 kg 140 kg m

    Stone-finTMWATER STILLStone-fin Advantages:

    Construction:

    v

    v

    v

    v

    v

    v

    v

    v

    v

    Eco friendly design - eliminates cruel wastage of water.

    With 4 lit Food Grade Distil late collection container.

    An innovative stand alone design works without a running water connection & hence the Stone-fin can beplaced just about anywhere; requires table top space of just 1.2 sq.ft.

    Clear bottom in Boiling chamber - enabling easy cleaning and no heater scaling problem.

    Connection to a 5 ampere wall socket allows easy and anywhere connectivity.

    Unattended operation - shuts itself off after completion of distillation.

    Requires no skilled labour. Lowest cost of distillation.

    Stainless Steel Chamber with stainless steel condenser piping.

    A continuously rated fan motor. #S1112-10

    Fill it, Shut it, Forget it

    #7674T

    Model Product

    #7674T Stone-fin Water Still 4 litres / 4 hrs

    Capacity

    4.2 kg / 4.8 kg / 0.06 m

    App. Shipping DetailsNet / Gr. / Volume

    OPTIONAL ACCESSORY

    Capacity

    750 W

    Heater

    0.3 kg / 1.0 kg / 0.011 m4L - for Water Still#S1112-10Distillate Collector -Transparent w/cap

    0061_

    0906-0-4


Recommended