+ All Categories
Home > Documents > Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program...

Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program...

Date post: 01-Apr-2015
Category:
Upload: draven-greenfield
View: 221 times
Download: 2 times
Share this document with a friend
17
Automation and Drives Siemens Flow Instruments A/S The Flow Force.ppt April 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on SITRANS F US Applications Back to animation Your search is over SONO 3100 FUS380/FUE380 SONO 3300 SONO 3300 CT SONOKIT - Retrofit Dedicated Program SITRANS F US Clamp-on A wide selection of flowmeters – both wetted and clamp- on solutions - makes it simple for you to choose the best flowmeter for your application
Transcript
Page 1: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 1

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

Your search is over

SONO 3100 FUS380/FUE380 SONO 3300

SONO 3300 CT SONOKIT - Retrofit

Dedicated Program SITRANS F US

Clamp-on

A wide selection of flowmeters – both wetted and clamp-on solutions - makes it simple for you to choose the best flowmeter for your application

Page 2: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 2

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

Two-track technology based on the transit time technique Direct shot sound transmission Optimum reliability and accuracy compared with

e.g. Doppler meters

Working principleTwo-track sensor construction

One of the keys to SITRANS F US flow meter precision performance is its direct shot ultra-sound transmission technique.

It shoots ultrasound pulses directly to the receiving transducer without bouncing them off the interior walls of the pipe.

This way, the presence of any scale build-up on interior pipe walls will not weaken or degrade transmitted signals.

Dedicated Program SITRANS F US

Page 3: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 3

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

Transmitter FUS060 Ultrasonic flowmetering at its best

Ideal for Oil, petrochemicals, power plants or water and wastewater

Enclosure rating IP67/NEMA 4X/6 Communication via PROFIBUS PA, HART ATEX Approval, ATEX II 2 G EEx d (e)/(ia) ib IIC T6 FUS060 meets the requirements of the OIML R117

custody transfer standards FUS060 offers a repeatability of <±0.15% of flow

SITRANS FUS060 -High performance for rugged industries

SITRANS F US in-line ultrasonic flow meters

SITRANS F US Wetted

Page 4: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 4

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

Sensor SONO 3100 Ideal for petro-chemical, water and treated

waste water Available in two/four track versions Available in e.g. Carbon steel, Stainless steel,

Duplex steel Change of transducer without process shut down Accuracy better than 0.5% of rate

DN 100 to 300 AISI (standard) DN 350 to 1200 carbon steel (std) PN 6 – PN 40 Max 200 °C Flange transducer or O-ring types EEx d IIC T2-T6

SITRANS F US Wetted

SITRANS F US in-line ultrasonic flow meters

Page 5: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 5

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

SITRANS FUS/E380 New battery or mains powered ultrasonic flowmeter dedicated to district heating, cooling, water,

and utility Two track design for rough installation conditions Battery power up to 6 years+

DN 100 mm – 800 mm Comply with EN 1434 and OIML R 75 87 V - 250 V ac - Backup possibility No pressure drops Compact or remote mounting

- Temperatures up to 200 °C- Compact version 120 °C

Preset pulse output for heat meters Fast measuring sequence

20 Hz / 0.5 Hz (net/bat)

SITRANS F US Wetted

SITRANS F US in-line ultrasonic flow meters

Page 6: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 6

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

Sensor SONO 3300 Multi-purpose flow meter for water, treated waste water, district heating, HVAC Remote or compact versions Two track design for rough installation conditions Accuracy better than 0.5 %

DN 50 to DN 150 cast iron DN 200 to DN 300 welded steel PN 10 – 40 Max 160 °C. IP 67 EEx d IIC T3-T6

SITRANS F US Wetted

SITRANS F US in-line ultrasonic flow meters

Page 7: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 7

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

Sensor SONO 3300/3000 CT Special designed ultrasonic flow meter for district

heating application Custody transfer - approved in many countries Choice of different transmitters (SONO 3000) Accuracy better than 0.5 %

DN 50 to DN 1200 Qmax: 15 - 6000 m3/h Mild steel St. 35 Temperatures up to 200 o C Flanged version PN 16/25/40 No pressure drop Outputs (analog, relay and

frequency/pulse

SITRANS F US Wetted

SITRANS F US in-line ultrasonic flow meters

Page 8: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 8

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

SONOKIT is based on the same technique and performance as SONO 3000/3100, and available in sizes from DN 200 to DN 4000. SONOKIT offers a simple, accurate alternative to traditional flow meters.

This practical ”mounting kit” contains everything you need to install a flow meter on an existing pipeline, with the help of a few ordinary tools.

SONOKIT Ideal for water / treated waste water pipes > DN 200 Cost effective solution for retrofitting based on wetted

transducers Retrofitting with/without process shut down! Automatic calculation of calibration data based on

geometry data.

SITRANS F US Wetted

SITRANS F US in-line ultrasonic flow meters

Page 9: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 9

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

Tapping bandSiemens Flow Instruments A/S also offer tapping band flowmeters for retrofitting non-weldable pipes (concrete and cast iron)

Sizes DN 200 to DN 1800 Pressure rating PN 6 – PN 16 depending on size

Retrofitting with/without process shut down

Tapping band material AISI 316 stainless steel

Supplied in 2/4/6 sections depending

on pipe sizeSITRANS F US Wetted

SITRANS F US in-line ultrasonic flow meters

Page 10: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 10

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

Siemens offers a comprehensive selection of clamp-on ultrasonic flow meters for Water & waste

water Chemical Food & beverage Mining

AggregatesCement

Pharmaceutical Paper & pulp Power & utilities

SITRANS F US clamp-on ultrasonic flow meters

SITRANS F US Clamp-on Ultrasonic Flow metersDelivering industry-leading performance

SITRANS F US Clamp-on

Page 11: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 11

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

F US 1010 Clamp-on Flow meters Ideal for measuring HVAC, power, water & waste

water, natural & process gas, liquid hydrocarbons and other general industries.

Patented WideBeam technology combines the advantages of the non-intrusive clamp-on technology

with a high precision accuracy.

SITRANS F US clamp-on ultrasonic flow meters

Install easily without cutting the pipe or shutting down operation

No periodic cleaning and no moving parts to wear or foul No pressure drop or energy loss

Flow surveys or temporary installation Large pipe diameters up to 9140 mm (360”)

Wide turn down ratios

Ultrasonic clamp-on flow meters from Controlotron strengthens Process Instrumentation of Siemens

SITRANS F US Clamp-on

Page 12: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 12

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

SITRANS FUE1010 Multi-purpose flow meter for HVAC and power industries Have built-in BTU calculators, measuring hot and chilled water Measure both flow and energy; don’t require a separate energy measurement system Offer dedicated and portable meters

Accuracy ±0.5%...1.0% of flow, for velocities greater than 0.3 m/s (1 ft/s) Flow range 0...18 m/s (0...60 ft/s), bidirectional Flow sensitivity 0.0003 m/s (0.001 ft/s) Pipe size 6.4 mm...9.14 m (0.25”...360”) Communications RS232, MODBUS/ N2, modem

SITRANS F US clamp-on ultrasonic flow meters

SITRANS F US Clamp-on

Page 13: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 13

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

SITRANS FUS1010 and FUS1020 Ultrasonic flow meters engineered to measure applications found in municipal and industrial water and wastewater industries Offer high precision, quick installation and low

maintenance Have transit-time and doppler modes of operation Accuracy better than 0.5 %

SITRANS FUP1010 is available in a standard portable or rugged submersible portable enclosure.

SITRANS FUS1020 is a basic flow meter that provides affordable high performance for many flow measurement applications. WideBeam Transit-Time operation is provided but Doppler

SITRANS F US clamp-on ultrasonic flow meters

SITRANS F US Clamp-on

Page 14: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 14

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

SITRANS FUH1010 Are ideal for crude oil, refined petroleum or liquefied gas applications Minimal maintenance with no moving parts to wear or foul and no pressure drop or energy loss 3 meter catagories: Interface detectors/density meters, Viscosity compensated volumetric flowmeter, and Standard volume (net) mass

flowmeter Accuracy better than 0.5 %

Repeatability ±0.15%...0.3% of flow, depending on version ±0.05 of API # for interface detectors/density meters Flow range ±12 m/s (± 40 ft/s), bi- directional Flow sensitivity 0.0003 m/s (0.001 ft/s) Pipe size 6.4 mm...9.14 m (0.25”...360”) Communications RS232, MODBUS, Ethernet, modem

SITRANS F US clamp-on ultrasonic flow meters

SITRANS F US Clamp-on

Page 15: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 15

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

SITRANS FUG1010 Ideal for most natural and process gas industry

applications, including checkmetering, allocation, flow survey verification, production, and more.

There is no need to cut the pipe or stop the flow External transducers do not require periodic cleaning No moving parts to wear or foul Eliminates the pressure drop or energy loss Wide turn-down ratio

Accuracy 1%...2% of actual volume reading (higher accuracy is pipe condition and flow profile dependent) 7...10 bar (100...145 psi), typical Flow range ±30 m/s (± 100 ft/s), bidirectional Flow sensitivity 0.0003 m/s (0.001 ft/s) Pipe size 25 mm...1.52 m (1”...60”) Communications RS232

SITRANS F US clamp-on ultrasonic flow meters

SITRANS F US Clamp-on

Page 16: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 16

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

SITRANS FUP1010 Ideal portable solution for plant surveys Easily moved from one job site to another A standard portable meter with a compact plastic

IP40 (NEMA 12) enclosure intended for indoor use. A waterproof portable meter with an IP67/63 (NEMA

6/3R) enclosure ideal for outdoor use. Both meters operate with transit-time and doppler

Flow range ± 12 m/s (±40 ft/s), bidirectional Accuracy ±0.5%...2% of flow, for velocities greater than 0.3 m/s (1 ft/s) Flow sensitivity 0.0003 m/s (0.001 ft/s) Pipe size 6.4 mm...9.14 m (0.25”...360”) Communications RS232

SITRANS F US clamp-on ultrasonic flow meters

SITRANS F US Clamp-on

Page 17: Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Dedicated Program SITRANS F US SITRANS F US Wetted SITRANS F US Clamp-on.

Automation and Drives

Siemens Flow Instruments A/S

The Flow Force.ppt April 2007 17

Dedicated Program SITRANS F US

SITRANS F US Wetted

SITRANS F US Clamp-on

SITRANS F US Applications

Back to animation

SITRANS F US applications

Siemens delivers industry specific solutions for

Off-Shore and On-Shore Installations Liquid Hydrocarbon Water & Wastewater Natural and Process Gas HVAC and Power Chemical Processes Pulp & Paper Irrigation Cryogenics

SITRANS F US Applications


Recommended