P 1800426272 E [email protected] W waterplex.com.au 1800 4 ANCRA www.ancraaustralia.com
Features and Benefits
AW Pump StationsWastewater and Stormwater
TELESCOPICLIDSHAFTS• Telescopic Shaft 140-440mm• Lid sits flush with ground level• 5 Degree tilt adjustment for slopes and driveways• Child-proof lockable lids
MULTIPLEINLETPORTSANDLIFTINGLUGS• Stainless steel lifting lugs • Multiple inlet ports• 100 - 150m inlet ports
PRE-PACKAGEDFITTINGS• Pre-assembled manifolds• Includes barrel unions, shut off valves,
non-return valves
VARIETYOFLIDS• Pedestrian Lid 150kg • Solid Cast Iron Lid - Class B & D• Grated Lids - Class B & D • Extension risers available
GROUNDWATERSTABLE• Patented floatation resistant design• Ground water stable up to 430mm from base
WARRANTYANDSERVICES• 15 Years - Chamber • 2 Years - Pumps
RAPIDDELIVERY• Once your order has been placed, you can
expect delivery to your local supplier within days of the order being received.
GERMANDESIGN• Structural ribbing reduces weight and allows
vehicle loading• Certified to AS1546.1• Award winning German design• Manufactured and assembled in Australia
QUALITYXYLEMPUMPS• Unparalleled performance and reliability• Compact & light-weight• Double mechanical seals• Surface hardened shredder mechanism• Pressure sewer pump option
PumpOut Waterplex.indd 1 18/7/18 2:24 pm
P 1800426272 E [email protected] W waterplex.com.au 1800 4 ANCRA www.ancraaustralia.com
Technical InformationTechnical InformationTechnical Information
Support NationwideYou can rely on us, with our multiple stock locations, our product is available to be delivered almost anywhere in Australia within a few days.
AFTER SALES SERVICEWith 14 existing Workshops and Service teams, we are ready to assist with any enquiries, all you need to do is contact 1300 131 971 and speak to one of our dedicated team members.
COMMISSIONING SERVICES & MAINTENANCEOption of direct Xylem commissioning & maintenance contracts call Xylem on 13 19 14
SHAFT 600 L 900 L 1200 L
Weight 27kg 47kg 58kg
W Diameter 1125m
Diameter 1155 mm
Diameter 1155 mm
H 1045 mm 1344 mm 1699 mm
TANK 2700 L 3750 L 4800 L 6500 L
Weight 115kg 146kg 181kg 220kg
L 2080 mm 2280 mm 2280 mm 2390 mm
W 1565 mm 1755 mm 1985 mm 2190mm
H 1400 mm 1590 mm 1820 mm 2100mm
*HtotWith mini tank dome
1680 mm 1870 mm14/50
2100 mm 2380 mm
Ancra Australia250 Governor RoadBRAESIDE VIC 3195AUSTRALIA1800 426272www.waterplex.com.auwww.ancraaustralia.com
Ancra New Zealand17 Andrew Baxter DriveMANGERE, AUCKLAND 2022NEW ZEALAND0508 426 272 (0508 4 ANCRA)www.waterplex.co.nzwww.ancranz.com
Support NationwideYou can rely on us, with our multiple stock locations, our product is available to be delivered almost anywhere in Australia within a few days.AFTERSALESSERVICE With 14 existing workshops and service teams, we are ready to assist with any enquiries, all you need to do is contact 1800426272 and speak with one of our dedicated Team Members.
SAPPHIRE600L
1045 13
44 1669
200
200
200
742 80
3
1200
SAPPHIRE900L SAPPHIRE1200L Technical InformationTechnical Information
Support NationwideYou can rely on us, with our multiple stock locations, our product is available to be delivered almost anywhere in Australia within a few days.
AFTER SALES SERVICEWith 14 existing Workshops and Service teams, we are ready to assist with any enquiries, all you need to do is contact 1300 131 971 and speak to one of our dedicated team members.
COMMISSIONING SERVICES & MAINTENANCEOption of direct Xylem commissioning & maintenance contracts call Xylem on 13 19 14
SHAFT 600 L 900 L 1200 L
Weight 27kg 47kg 58kg
W Diameter 1125m
Diameter 1155 mm
Diameter 1155 mm
H 1045 mm 1344 mm 1699 mm
TANK 2700 L 3750 L 4800 L 6500 L
Weight 115kg 146kg 181kg 220kg
L 2080 mm 2280 mm 2280 mm 2390 mm
W 1565 mm 1755 mm 1985 mm 2190mm
H 1400 mm 1590 mm 1820 mm 2100mm
*HtotWith mini tank dome
1680 mm 1870 mm14/50
2100 mm 2380 mm
Ancra Australia250 Governor RoadBRAESIDE VIC 3195AUSTRALIA1800 426272www.waterplex.com.auwww.ancraaustralia.com
Ancra New Zealand17 Andrew Baxter DriveMANGERE, AUCKLAND 2022NEW ZEALAND0508 426 272 (0508 4 ANCRA)www.waterplex.co.nzwww.ancranz.com
Technical InformationTechnical Information
Support NationwideYou can rely on us, with our multiple stock locations, our product is available to be delivered almost anywhere in Australia within a few days.
AFTER SALES SERVICEWith 14 existing Workshops and Service teams, we are ready to assist with any enquiries, all you need to do is contact 1300 131 971 and speak to one of our dedicated team members.
COMMISSIONING SERVICES & MAINTENANCEOption of direct Xylem commissioning & maintenance contracts call Xylem on 13 19 14
SHAFT 600 L 900 L 1200 L
Weight 27kg 47kg 58kg
W Diameter 1125m
Diameter 1155 mm
Diameter 1155 mm
H 1045 mm 1344 mm 1699 mm
TANK 2700 L 3750 L 4800 L 6500 L
Weight 115kg 146kg 181kg 220kg
L 2080 mm 2280 mm 2280 mm 2390 mm
W 1565 mm 1755 mm 1985 mm 2190mm
H 1400 mm 1590 mm 1820 mm 2100mm
*HtotWith mini tank dome
1680 mm 1870 mm14/50
2100 mm 2380 mm
Ancra Australia250 Governor RoadBRAESIDE VIC 3195AUSTRALIA1800 426272www.waterplex.com.auwww.ancraaustralia.com
Ancra New Zealand17 Andrew Baxter DriveMANGERE, AUCKLAND 2022NEW ZEALAND0508 426 272 (0508 4 ANCRA)www.waterplex.co.nzwww.ancranz.com
TelescopicDomeShaft(Item 202079)
Minimum useful length Maximum useful length
PECover-SuitableforPedestrianLoading(Item 202803)
Top View Side View
CarModule(Item 202059)
Maximum useful length as intermediate piece
Top View
Side View
PumpOut Waterplex.indd 2 18/7/18 2:24 pm
GarantiaPedestrian Lid
• Lockable 600mm manhole
• 5 degree tilt• Pedestrian grade lid• Maximum 150kg loading
Garantia Grated Lid
• Suitable for surface water• Fully galvanised grate• Allows full access• Lockable 600mm manhole• Requires extension riser
Garantia Solid Lid
• Heavy duty cast iron lid• Lockable 600mm manhole• Max. load “B” 3.5 tonne• Max. load “D” 8 tonne• 5 degree tilt• Requires extension riser
Extension Riser (Optional)
• Optional extension riser is ideal in areas of low stormwater or sewer pipework.
• Adjusts to a Max of 550mm• Use a maximum of 2 risers
WP-AWPL10
Build your pump station as you go....Just follow the 4 easy steps! First, choose your chamber size!
• 600 Lt Chamber WP-AWP0600• 900 Lt Chamber WP-AWP0900• 1200 Lt Chamber WP-AWP1200
• 2700 Lt Chamber • 3750 Lt Chamber • 4800 Lt Chamber • 6500 Lt Chamber
Chamber includes seal kits. Garantia lids must be ordered separately.
Chambers - Step 1
WP-AWPL22 - CLASS DWP-AWPL02 - CLASS B
WP-AWPL21 - CLASS DWP-AWPL20 - CLASS B
WP-AWPL03
Lid & Riser options - Step 2
WP-AWP2700WP-AWP3750WP-AWP4800WP-AWP6500
GRAFPedestrian Lid
• Pedestrian grade lid• Maximum 150kg loading• Lockable 600mm
manhole• Adjustable 140mm to 340 mm• 5 degree tilt
GRAF Solid Lid
• Heavy duty cast iron lid• Lockable 600mm manhole• Max. load “B” 3.5 tonne• Max. load “D” 8 tonne• Adjustable 14mm to 440mm• 5 degree tilt
GRAF Grated Lid
• Fully galvanised grate • Allows full access• Lockable 600mm manhole• Trash grate available• Suitable for surface water• Adjustable 140mm - 440mm
Extension Riser (Optional)
• Optional extension riser is ideal in areas of low stormwater or sewer pipework.
• Adjusts to a Max of 360mm• Use a maximum of 2 risers
Lids for 600 - 1200 Litre Tanks
Lids for 2700 - 6500 Litre Tanks
Ancra Australia250 Governor RoadBRAESIDE VIC 3195AUSTRALIA1800 426272www.waterplex.com.auwww.ancraaustralia.com
Ancra New Zealand17 Andrew Baxter DriveMANGERE, AUCKLAND 2022NEW ZEALAND0508 426 272 (0508 4 ANCRA)www.waterplex.co.nzwww.ancranz.com
Chamber includes seal kits. GRAF Lids must be ordered separately.
WP-AWPL60WP-AWPL70WP-AWPL71
WP-AWPL52WP-AWPL72 WP-AWPL53
GarantiaPedestrian Lid
• Lockable 600mm manhole
• 5 degree tilt• Pedestrian grade lid• Maximum 150kg loading
Garantia Grated Lid
• Suitable for surface water• Fully galvanised grate• Allows full access• Lockable 600mm manhole• Requires extension riser
Garantia Solid Lid
• Heavy duty cast iron lid• Lockable 600mm manhole• Max. load “B” 3.5 tonne• Max. load “D” 8 tonne• 5 degree tilt• Requires extension riser
Extension Riser (Optional)
• Optional extension riser is ideal in areas of low stormwater or sewer pipework.
• Adjusts to a Max of 550mm• Use a maximum of 2 risers
WP-AWPL10
Build your pump station as you go....Just follow the 4 easy steps! First, choose your chamber size!
• 600 Lt Chamber WP-AWP0600• 900 Lt Chamber WP-AWP0900• 1200 Lt Chamber WP-AWP1200
• 2700 Lt Chamber • 3750 Lt Chamber • 4800 Lt Chamber • 6500 Lt Chamber
Chamber includes seal kits. Garantia lids must be ordered separately.
Chambers - Step 1
WP-AWPL22 - CLASS DWP-AWPL02 - CLASS B
WP-AWPL21 - CLASS DWP-AWPL20 - CLASS B
WP-AWPL03
Lid & Riser options - Step 2
WP-AWP2700WP-AWP3750WP-AWP4800WP-AWP6500
GRAFPedestrian Lid
• Pedestrian grade lid• Maximum 150kg loading• Lockable 600mm
manhole• Adjustable 140mm to 340 mm• 5 degree tilt
GRAF Solid Lid
• Heavy duty cast iron lid• Lockable 600mm manhole• Max. load “B” 3.5 tonne• Max. load “D” 8 tonne• Adjustable 14mm to 440mm• 5 degree tilt
GRAF Grated Lid
• Fully galvanised grate • Allows full access• Lockable 600mm manhole• Trash grate available• Suitable for surface water• Adjustable 140mm - 440mm
Extension Riser (Optional)
• Optional extension riser is ideal in areas of low stormwater or sewer pipework.
• Adjusts to a Max of 360mm• Use a maximum of 2 risers
Lids for 600 - 1200 Litre Tanks
Lids for 2700 - 6500 Litre Tanks
Ancra Australia250 Governor RoadBRAESIDE VIC 3195AUSTRALIA1800 426272www.waterplex.com.auwww.ancraaustralia.com
Ancra New Zealand17 Andrew Baxter DriveMANGERE, AUCKLAND 2022NEW ZEALAND0508 426 272 (0508 4 ANCRA)www.waterplex.co.nzwww.ancranz.com
Chamber includes seal kits. GRAF Lids must be ordered separately.
WP-AWPL60WP-AWPL70WP-AWPL71
WP-AWPL52WP-AWPL72 WP-AWPL53
GarantiaPedestrian Lid
• Lockable 600mm manhole
• 5 degree tilt• Pedestrian grade lid• Maximum 150kg loading
Garantia Grated Lid
• Suitable for surface water• Fully galvanised grate• Allows full access• Lockable 600mm manhole• Requires extension riser
Garantia Solid Lid
• Heavy duty cast iron lid• Lockable 600mm manhole• Max. load “B” 3.5 tonne• Max. load “D” 8 tonne• 5 degree tilt• Requires extension riser
Extension Riser (Optional)
• Optional extension riser is ideal in areas of low stormwater or sewer pipework.
• Adjusts to a Max of 550mm• Use a maximum of 2 risers
WP-AWPL10
Build your pump station as you go....Just follow the 4 easy steps! First, choose your chamber size!
• 600 Lt Chamber WP-AWP0600• 900 Lt Chamber WP-AWP0900• 1200 Lt Chamber WP-AWP1200
• 2700 Lt Chamber • 3750 Lt Chamber • 4800 Lt Chamber • 6500 Lt Chamber
Chamber includes seal kits. Garantia lids must be ordered separately.
Chambers - Step 1
WP-AWPL22 - CLASS DWP-AWPL02 - CLASS B
WP-AWPL21 - CLASS DWP-AWPL20 - CLASS B
WP-AWPL03
Lid & Riser options - Step 2
WP-AWP2700WP-AWP3750WP-AWP4800WP-AWP6500
GRAFPedestrian Lid
• Pedestrian grade lid• Maximum 150kg loading• Lockable 600mm
manhole• Adjustable 140mm to 340 mm• 5 degree tilt
GRAF Solid Lid
• Heavy duty cast iron lid• Lockable 600mm manhole• Max. load “B” 3.5 tonne• Max. load “D” 8 tonne• Adjustable 14mm to 440mm• 5 degree tilt
GRAF Grated Lid
• Fully galvanised grate • Allows full access• Lockable 600mm manhole• Trash grate available• Suitable for surface water• Adjustable 140mm - 440mm
Extension Riser (Optional)
• Optional extension riser is ideal in areas of low stormwater or sewer pipework.
• Adjusts to a Max of 360mm• Use a maximum of 2 risers
Lids for 600 - 1200 Litre Tanks
Lids for 2700 - 6500 Litre Tanks
Ancra Australia250 Governor RoadBRAESIDE VIC 3195AUSTRALIA1800 426272www.waterplex.com.auwww.ancraaustralia.com
Ancra New Zealand17 Andrew Baxter DriveMANGERE, AUCKLAND 2022NEW ZEALAND0508 426 272 (0508 4 ANCRA)www.waterplex.co.nzwww.ancranz.com
Chamber includes seal kits. GRAF Lids must be ordered separately.
WP-AWPL60WP-AWPL70WP-AWPL71
WP-AWPL52WP-AWPL72 WP-AWPL53
GarantiaPedestrian Lid
• Lockable 600mm manhole
• 5 degree tilt• Pedestrian grade lid• Maximum 150kg loading
Garantia Grated Lid
• Suitable for surface water• Fully galvanised grate• Allows full access• Lockable 600mm manhole• Requires extension riser
Garantia Solid Lid
• Heavy duty cast iron lid• Lockable 600mm manhole• Max. load “B” 3.5 tonne• Max. load “D” 8 tonne• 5 degree tilt• Requires extension riser
Extension Riser (Optional)
• Optional extension riser is ideal in areas of low stormwater or sewer pipework.
• Adjusts to a Max of 550mm• Use a maximum of 2 risers
WP-AWPL10
Build your pump station as you go....Just follow the 4 easy steps! First, choose your chamber size!
• 600 Lt Chamber WP-AWP0600• 900 Lt Chamber WP-AWP0900• 1200 Lt Chamber WP-AWP1200
• 2700 Lt Chamber • 3750 Lt Chamber • 4800 Lt Chamber • 6500 Lt Chamber
Chamber includes seal kits. Garantia lids must be ordered separately.
Chambers - Step 1
WP-AWPL22 - CLASS DWP-AWPL02 - CLASS B
WP-AWPL21 - CLASS DWP-AWPL20 - CLASS B
WP-AWPL03
Lid & Riser options - Step 2
WP-AWP2700WP-AWP3750WP-AWP4800WP-AWP6500
GRAFPedestrian Lid
• Pedestrian grade lid• Maximum 150kg loading• Lockable 600mm
manhole• Adjustable 140mm to 340 mm• 5 degree tilt
GRAF Solid Lid
• Heavy duty cast iron lid• Lockable 600mm manhole• Max. load “B” 3.5 tonne• Max. load “D” 8 tonne• Adjustable 14mm to 440mm• 5 degree tilt
GRAF Grated Lid
• Fully galvanised grate • Allows full access• Lockable 600mm manhole• Trash grate available• Suitable for surface water• Adjustable 140mm - 440mm
Extension Riser (Optional)
• Optional extension riser is ideal in areas of low stormwater or sewer pipework.
• Adjusts to a Max of 360mm• Use a maximum of 2 risers
Lids for 600 - 1200 Litre Tanks
Lids for 2700 - 6500 Litre Tanks
Ancra Australia250 Governor RoadBRAESIDE VIC 3195AUSTRALIA1800 426272www.waterplex.com.auwww.ancraaustralia.com
Ancra New Zealand17 Andrew Baxter DriveMANGERE, AUCKLAND 2022NEW ZEALAND0508 426 272 (0508 4 ANCRA)www.waterplex.co.nzwww.ancranz.com
Chamber includes seal kits. GRAF Lids must be ordered separately.
WP-AWPL60WP-AWPL70WP-AWPL71
WP-AWPL52WP-AWPL72 WP-AWPL53
• Lockable 600mmmanhole
• 5 degree tilt• Pedestrian grade lid• Maximum 150kg loading
• Suitable for surface water• Fully galvanised grate• Allows full access• Lockable 600mm manhole• Requires extension riser
• Heavy duty cast iron lid• Lockable 600mm manhole• Max. load “B” 3.5 tonne• Max. load “D” 8 tonne• 5 degree tilt• Requires extension riser
Extension Riser
• Optional extension riseris ideal in areas of lowstormwater or sewerpipework.
• Adjusts to a Max of 550mm• Use a maximum of 2 risers
Garantia Pedestrian Lid
WP-AWPL10
Build your pump station as you go....Just follow the 4 easy steps! First, choose your chamber size!
• 600 Lt Chamber WP-AWP0600• 900 Lt Chamber WP-AWP0900• 1200 Lt Chamber WP-AWP1200
• 2700 Lt Chamber• 3750 Lt Chamber• 4800 Lt Chamber• 6500 Lt Chamber
Chamber includes seal kits. Garantia lids must be ordered separately.
Chambers - Step 1
Garantia Grated Lid WP-AWPL02 - CLASS B WP-AWPL22 - CLASS D
Garantia Solid Lid WP-AWPL20 - CLASS B WP-AWPL21 - CLASS D
(Optional) WP-AWPL03
Lid & Riser options - Step 2
WP-AWP2700WP-AWP3750WP-AWP4800WP-AWP6500
• Pedestrian grade lid• Maximum 150kg loading• Lockable 600mm manhole• Adjustable 140mm to 340mm• 5 degree tilt
GRAF Solid Lid
• Heavy duty cast iron lid• Lockable 600mm manhole• Max. load “B” 3.5 tonne• Max. load “D” 8 tonne• Adjustable 14mm to 440mm• 5 degree tilt
• Fully galvanised grate• Allows full access• Lockable 600mm manhole• Trash grate available• Suitable for surface water• Adjustable 140mm - 440mm
Extension Riser
• Optional extension riser is ideal in areas of low stormwater or sewer pipework
• Adjusts to a Max of 360mm• Use a maximum of 2 risers
Lids for 600 - 1200 Litre Tanks
Lids for 2700 - 6500 Litre Tanks
Ancra Australia250 Governor RoadBRAESIDE VIC 3195AUSTRALIA1800 426272www.waterplex.com.auwww.ancraaustralia.com
Ancra New Zealand17 Andrew Baxter DriveMANGERE, AUCKLAND 2022NEW ZEALAND0508 426 272 (0508 4 ANCRA)www.waterplex.co.nzwww.ancranz.com
Chamber includes seal kits. GRAF Lids must be ordered separately.
GRAF Pedestrian Lid
WP-AWPL60WP-AWPL70 WP-AWPL71
GRAF Grated Lid WP-AWPL52WP-AWPL72
(Optional) WP-AWPL53
• Lockable 600mmmanhole
• 5 degree tilt• Pedestrian grade lid• Maximum 150kg loading
• Suitable for surface water• Fully galvanised grate• Allows full access• Lockable 600mm manhole• Requires extension riser
• Heavy duty cast iron lid• Lockable 600mm manhole• Max. load “B” 3.5 tonne• Max. load “D” 8 tonne• 5 degree tilt• Requires extension riser
Extension Riser
• Optional extension riseris ideal in areas of lowstormwater or sewerpipework.
• Adjusts to a Max of 550mm• Use a maximum of 2 risers
Garantia Pedestrian Lid
WP-AWPL10
Build your pump station as you go....Just follow the 4 easy steps! First, choose your chamber size!
• 600 Lt Chamber WP-AWP0600• 900 Lt Chamber WP-AWP0900• 1200 Lt Chamber WP-AWP1200
• 2700 Lt Chamber• 3750 Lt Chamber• 4800 Lt Chamber• 6500 Lt Chamber
Chamber includes seal kits. Garantia lids must be ordered separately.
Chambers - Step 1
Garantia Grated Lid WP-AWPL02 - CLASS B WP-AWPL22 - CLASS D
Garantia Solid Lid WP-AWPL20 - CLASS B WP-AWPL21 - CLASS D
(Optional) WP-AWPL03
Lid & Riser options - Step 2
WP-AWP2700WP-AWP3750WP-AWP4800WP-AWP6500
• Pedestrian grade lid• Maximum 150kg loading• Lockable 600mm manhole• Adjustable 140mm to 340mm• 5 degree tilt
GRAF Solid Lid
• Heavy duty cast iron lid• Lockable 600mm manhole• Max. load “B” 3.5 tonne• Max. load “D” 8 tonne• Adjustable 14mm to 440mm• 5 degree tilt
• Fully galvanised grate• Allows full access• Lockable 600mm manhole• Trash grate available• Suitable for surface water• Adjustable 140mm - 440mm
Extension Riser
• Optional extension riser is ideal in areas of low stormwater or sewer pipework
• Adjusts to a Max of 360mm• Use a maximum of 2 risers
Lids for 600 - 1200 Litre Tanks
Lids for 2700 - 6500 Litre Tanks
Ancra Australia250 Governor RoadBRAESIDE VIC 3195AUSTRALIA1800 426272www.waterplex.com.auwww.ancraaustralia.com
Ancra New Zealand17 Andrew Baxter DriveMANGERE, AUCKLAND 2022NEW ZEALAND0508 426 272 (0508 4 ANCRA)www.waterplex.co.nzwww.ancranz.com
Chamber includes seal kits. GRAF Lids must be ordered separately.
GRAF Pedestrian Lid
WP-AWPL60WP-AWPL70 WP-AWPL71
GRAF Grated Lid WP-AWPL52WP-AWPL72
(Optional) WP-AWPL53
P 1800426272 E [email protected] W waterplex.com.au 1800 4 ANCRA www.ancraaustralia.com
Lid & Riser Options - Step 2
Chambers - Step 1
• 600 Litre Chamber WP-AWP0600 • 900 Litre Chamber WP-AWP0900 • 1200 Litre Chamber WP-AWP1200 • 270 Litre Chamber WP-AWP2700 • 3750 Litre Chamber WP-AWP3750 • 4800 Litre Chamber WP-AWP4800 • 6500 Litre Chamber WP-AWP6500
Chamber includes seal kits. GarantiaandGRAFlids must be ordered separately. (See below)
Build your Pump Station as you go.... Just follow the 4 easy steps:
PumpOut Waterplex.indd 3 18/7/18 2:24 pm
Pump Options - Step 3
Control Equipment - Step 4
P 1800426272 E [email protected] W waterplex.com.au 1800 4 ANCRA www.ancraaustralia.com
AW Stormwater Pump AW Stormwater Pump• 2 l/s@6m• Medium flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.55kW• Current:3.91amp• Voltage: 250V• Solids handling: 35mm• IP Rating: 68
• 5 l/s@6m• High flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.75kW• Current:5.84amp• Voltage: 240V• Solids handling:
35mm• IP Rating: 68
AW Stormwater Pump• 8 l/s@6m• Higher flow pump
for stormwater applications
• Cable length: 10m• Power Rating: 1.1kW• Current:• Voltage: 240V• Solids handling: 15mm• IP Rating: 68
AW Wastewater Pump
• 3 l/s@6m• Cutter pump for
stormwaterapplications
• Cable length:10m
• Power Rating:0.75kW
• Current:6.5A• Voltage: 240V• IP Rating: 68
Pump Options - Step 3WPAWXS0206 WPAWXS0506 WPAWXS1006
WPAWXW0306
AW Wastewater Pump
• 0.7 l/s@20m• Grinder pump for
medium sewerapplications
• Cable length: 10m• Current:6.84A• Voltage: 240V• Power Rating:
1.1kW
WPAWXW0720
AW Wastewater Pump
• 0.5 l/s@40m• High head pump
for pressure sewerapplications
• Cable length: 10m• Current:6.1A• Voltage: 240V• Power Rating:
0.9kW
WPAWXW0540
Stormwater Wastewater Manifolds
All manifolds come complete with watermarked fittings including:• Barrell Unions• Non-return and shut
off valves• Fitted into 50mm
PVC pressure pipe
WPAWSFM - SINGLEWPAWDFM - DOUBLE
• Built in overload circuit breaker (s)• Power size up to 1.5kW
(power output for pump up to 12a)• Auto test function• Pump rotation option• Real time clock with hour counter• Dry ryn, overload and short circuit protection• High level alarm included
Single/Dual Pump Controllers
WPAWSPC - SINGLEWPAWDPC - DOUBLE
AW Pump Curve
Control Equipment - Step 4High Level Alarm
Warning condition determined by a Float switch.Warning alarms are:Audio - BuzzerThe buzzer can be muted via the mute button. The visual alarms will remain on until the alarm condition is eradicated.
WPAWHLA
AW Stormwater Pump AW Stormwater Pump• 2 l/s@6m• Medium flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.55kW• Current:3.91amp• Voltage: 250V• Solids handling: 35mm• IP Rating: 68
• 5 l/s@6m• High flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.75kW• Current:5.84amp• Voltage: 240V• Solids handling:
35mm• IP Rating: 68
AW Stormwater Pump• 8 l/s@6m• Higher flow pump
for stormwater applications
• Cable length: 10m• Power Rating: 1.1kW• Current:• Voltage: 240V• Solids handling: 15mm• IP Rating: 68
AW Wastewater Pump
• 3 l/s@6m• Cutter pump for
stormwaterapplications
• Cable length:10m
• Power Rating:0.75kW
• Current:6.5A• Voltage: 240V• IP Rating: 68
Pump Options - Step 3WPAWXS0206 WPAWXS0506 WPAWXS1006
WPAWXW0306
AW Wastewater Pump
• 0.7 l/s@20m• Grinder pump for
medium sewerapplications
• Cable length: 10m• Current:6.84A• Voltage: 240V• Power Rating:
1.1kW
WPAWXW0720
AW Wastewater Pump
• 0.5 l/s@40m• High head pump
for pressure sewerapplications
• Cable length: 10m• Current:6.1A• Voltage: 240V• Power Rating:
0.9kW
WPAWXW0540
Stormwater Wastewater Manifolds
All manifolds come complete with watermarked fittings including:• Barrell Unions• Non-return and shut
off valves• Fitted into 50mm
PVC pressure pipe
WPAWSFM - SINGLEWPAWDFM - DOUBLE
• Built in overload circuit breaker (s)• Power size up to 1.5kW
(power output for pump up to 12a)• Auto test function• Pump rotation option• Real time clock with hour counter• Dry ryn, overload and short circuit protection• High level alarm included
Single/Dual Pump Controllers
WPAWSPC - SINGLEWPAWDPC - DOUBLE
AW Pump Curve
Control Equipment - Step 4High Level Alarm
Warning condition determined by a Float switch.Warning alarms are:Audio - BuzzerThe buzzer can be muted via the mute button. The visual alarms will remain on until the alarm condition is eradicated.
WPAWHLA
AW Stormwater Pump AW Stormwater Pump• 2 l/s@6m• Medium flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.55kW• Current:3.91amp• Voltage: 250V• Solids handling: 35mm• IP Rating: 68
• 5 l/s@6m• High flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.75kW• Current:5.84amp• Voltage: 240V• Solids handling:
35mm• IP Rating: 68
AW Stormwater Pump• 8 l/s@6m• Higher flow pump
for stormwater applications
• Cable length: 10m• Power Rating: 1.1kW• Current:• Voltage: 240V• Solids handling: 15mm• IP Rating: 68
AW Wastewater Pump
• 3 l/s@6m• Cutter pump for
stormwaterapplications
• Cable length:10m
• Power Rating:0.75kW
• Current:6.5A• Voltage: 240V• IP Rating: 68
Pump Options - Step 3WPAWXS0206 WPAWXS0506 WPAWXS1006
WPAWXW0306
AW Wastewater Pump
• 0.7 l/s@20m• Grinder pump for
medium sewerapplications
• Cable length: 10m• Current:6.84A• Voltage: 240V• Power Rating:
1.1kW
WPAWXW0720
AW Wastewater Pump
• 0.5 l/s@40m• High head pump
for pressure sewerapplications
• Cable length: 10m• Current:6.1A• Voltage: 240V• Power Rating:
0.9kW
WPAWXW0540
Stormwater Wastewater Manifolds
All manifolds come complete with watermarked fittings including:• Barrell Unions• Non-return and shut
off valves• Fitted into 50mm
PVC pressure pipe
WPAWSFM - SINGLEWPAWDFM - DOUBLE
• Built in overload circuit breaker (s)• Power size up to 1.5kW
(power output for pump up to 12a)• Auto test function• Pump rotation option• Real time clock with hour counter• Dry ryn, overload and short circuit protection• High level alarm included
Single/Dual Pump Controllers
WPAWSPC - SINGLEWPAWDPC - DOUBLE
AW Pump Curve
Control Equipment - Step 4High Level Alarm
Warning condition determined by a Float switch.Warning alarms are:Audio - BuzzerThe buzzer can be muted via the mute button. The visual alarms will remain on until the alarm condition is eradicated.
WPAWHLA
AW Stormwater Pump AW Stormwater Pump• 2 l/s@6m• Medium flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.55kW• Current:3.91amp• Voltage: 250V• Solids handling: 35mm• IP Rating: 68
• 5 l/s@6m• High flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.75kW• Current:5.84amp• Voltage: 240V• Solids handling:
35mm• IP Rating: 68
AW Stormwater Pump• 8 l/s@6m• Higher flow pump
for stormwater applications
• Cable length: 10m• Power Rating: 1.1kW• Current:• Voltage: 240V• Solids handling: 15mm• IP Rating: 68
AW Wastewater Pump
• 3 l/s@6m• Cutter pump for
stormwaterapplications
• Cable length:10m
• Power Rating:0.75kW
• Current:6.5A• Voltage: 240V• IP Rating: 68
Pump Options - Step 3WPAWXS0206 WPAWXS0506 WPAWXS1006
WPAWXW0306
AW Wastewater Pump
• 0.7 l/s@20m• Grinder pump for
medium sewerapplications
• Cable length: 10m• Current:6.84A• Voltage: 240V• Power Rating:
1.1kW
WPAWXW0720
AW Wastewater Pump
• 0.5 l/s@40m• High head pump
for pressure sewerapplications
• Cable length: 10m• Current:6.1A• Voltage: 240V• Power Rating:
0.9kW
WPAWXW0540
Stormwater Wastewater Manifolds
All manifolds come complete with watermarked fittings including:• Barrell Unions• Non-return and shut
off valves• Fitted into 50mm
PVC pressure pipe
WPAWSFM - SINGLEWPAWDFM - DOUBLE
• Built in overload circuit breaker (s)• Power size up to 1.5kW
(power output for pump up to 12a)• Auto test function• Pump rotation option• Real time clock with hour counter• Dry ryn, overload and short circuit protection• High level alarm included
Single/Dual Pump Controllers
WPAWSPC - SINGLEWPAWDPC - DOUBLE
AW Pump Curve
Control Equipment - Step 4High Level Alarm
Warning condition determined by a Float switch.Warning alarms are:Audio - BuzzerThe buzzer can be muted via the mute button. The visual alarms will remain on until the alarm condition is eradicated.
WPAWHLA
AW Stormwater Pump AW Stormwater Pump• 2 l/s@6m• Medium flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.55kW• Current:3.91amp• Voltage: 250V• Solids handling: 35mm• IP Rating: 68
• 5 l/s@6m• High flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.75kW• Current:5.84amp• Voltage: 240V• Solids handling:
35mm• IP Rating: 68
AW Stormwater Pump• 8 l/s@6m• Higher flow pump
for stormwater applications
• Cable length: 10m• Power Rating: 1.1kW• Current:• Voltage: 240V• Solids handling: 15mm• IP Rating: 68
AW Wastewater Pump
• 3 l/s@6m• Cutter pump for
stormwaterapplications
• Cable length:10m
• Power Rating:0.75kW
• Current:6.5A• Voltage: 240V• IP Rating: 68
Pump Options - Step 3WPAWXS0206 WPAWXS0506 WPAWXS1006
WPAWXW0306
AW Wastewater Pump
• 0.7 l/s@20m• Grinder pump for
medium sewerapplications
• Cable length: 10m• Current:6.84A• Voltage: 240V• Power Rating:
1.1kW
WPAWXW0720
AW Wastewater Pump
• 0.5 l/s@40m• High head pump
for pressure sewerapplications
• Cable length: 10m• Current:6.1A• Voltage: 240V• Power Rating:
0.9kW
WPAWXW0540
Stormwater Wastewater Manifolds
All manifolds come complete with watermarked fittings including:• Barrell Unions• Non-return and shut
off valves• Fitted into 50mm
PVC pressure pipe
WPAWSFM - SINGLEWPAWDFM - DOUBLE
• Built in overload circuit breaker (s)• Power size up to 1.5kW
(power output for pump up to 12a)• Auto test function• Pump rotation option• Real time clock with hour counter• Dry ryn, overload and short circuit protection• High level alarm included
Single/Dual Pump Controllers
WPAWSPC - SINGLEWPAWDPC - DOUBLE
AW Pump Curve
Control Equipment - Step 4High Level Alarm
Warning condition determined by a Float switch.Warning alarms are:Audio - BuzzerThe buzzer can be muted via the mute button. The visual alarms will remain on until the alarm condition is eradicated.
WPAWHLA
AW Stormwater Pump AW Stormwater Pump• 2 l/s@6m• Medium flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.55kW• Current:3.91amp• Voltage: 250V• Solids handling: 35mm• IP Rating: 68
• 5 l/s@6m• High flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.75kW• Current:5.84amp• Voltage: 240V• Solids handling:
35mm• IP Rating: 68
AW Stormwater Pump• 8 l/s@6m• Higher flow pump
for stormwater applications
• Cable length: 10m• Power Rating: 1.1kW• Current:• Voltage: 240V• Solids handling: 15mm• IP Rating: 68
AW Wastewater Pump
• 3 l/s@6m• Cutter pump for
stormwaterapplications
• Cable length:10m
• Power Rating:0.75kW
• Current:6.5A• Voltage: 240V• IP Rating: 68
Pump Options - Step 3WPAWXS0206 WPAWXS0506 WPAWXS1006
WPAWXW0306
AW Wastewater Pump
• 0.7 l/s@20m• Grinder pump for
medium sewerapplications
• Cable length: 10m• Current:6.84A• Voltage: 240V• Power Rating:
1.1kW
WPAWXW0720
AW Wastewater Pump
• 0.5 l/s@40m• High head pump
for pressure sewerapplications
• Cable length: 10m• Current:6.1A• Voltage: 240V• Power Rating:
0.9kW
WPAWXW0540
Stormwater Wastewater Manifolds
All manifolds come complete with watermarked fittings including:• Barrell Unions• Non-return and shut
off valves• Fitted into 50mm
PVC pressure pipe
WPAWSFM - SINGLEWPAWDFM - DOUBLE
• Built in overload circuit breaker (s)• Power size up to 1.5kW
(power output for pump up to 12a)• Auto test function• Pump rotation option• Real time clock with hour counter• Dry ryn, overload and short circuit protection• High level alarm included
Single/Dual Pump Controllers
WPAWSPC - SINGLEWPAWDPC - DOUBLE
AW Pump Curve
Control Equipment - Step 4High Level Alarm
Warning condition determined by a Float switch.Warning alarms are:Audio - BuzzerThe buzzer can be muted via the mute button. The visual alarms will remain on until the alarm condition is eradicated.
WPAWHLA
AW Stormwater Pump AW Stormwater Pump• 2 l/s@6m• Medium flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.55kW• Current:3.91amp• Voltage: 250V• Solids handling: 35mm• IP Rating: 68
• 5 l/s@6m• High flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.75kW• Current:5.84amp• Voltage: 240V• Solids handling:
35mm• IP Rating: 68
AW Stormwater Pump• 8 l/s@6m• Higher flow pump
for stormwater applications
• Cable length: 10m• Power Rating: 1.1kW• Current:• Voltage: 240V• Solids handling: 15mm• IP Rating: 68
AW Wastewater Pump
• 3 l/s@6m• Cutter pump for
stormwaterapplications
• Cable length:10m
• Power Rating:0.75kW
• Current:6.5A• Voltage: 240V• IP Rating: 68
Pump Options - Step 3WPAWXS0206 WPAWXS0506 WPAWXS1006
WPAWXW0306
AW Wastewater Pump
• 0.7 l/s@20m• Grinder pump for
medium sewerapplications
• Cable length: 10m• Current:6.84A• Voltage: 240V• Power Rating:
1.1kW
WPAWXW0720
AW Wastewater Pump
• 0.5 l/s@40m• High head pump
for pressure sewerapplications
• Cable length: 10m• Current:6.1A• Voltage: 240V• Power Rating:
0.9kW
WPAWXW0540
Stormwater Wastewater Manifolds
All manifolds come complete with watermarked fittings including:• Barrell Unions• Non-return and shut
off valves• Fitted into 50mm
PVC pressure pipe
WPAWSFM - SINGLEWPAWDFM - DOUBLE
• Built in overload circuit breaker (s)• Power size up to 1.5kW
(power output for pump up to 12a)• Auto test function• Pump rotation option• Real time clock with hour counter• Dry ryn, overload and short circuit protection• High level alarm included
Single/Dual Pump Controllers
WPAWSPC - SINGLEWPAWDPC - DOUBLE
AW Pump Curve
Control Equipment - Step 4High Level Alarm
Warning condition determined by a Float switch.Warning alarms are:Audio - BuzzerThe buzzer can be muted via the mute button. The visual alarms will remain on until the alarm condition is eradicated.
WPAWHLA
All manifolds come complete with watermarked fittings including:• Barrell Unions • Non-return and shutoff valves • Fitted into 50mm PVC pressure pipe
AW Stormwater Pump AW Stormwater Pump• 2 l/s@6m• Medium flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.55kW• Current:3.91amp• Voltage: 250V• Solids handling: 35mm• IP Rating: 68
• 5 l/s@6m• High flow pump
for stormwaterapplications
• Cable length: 10m• Power Rating: 0.75kW• Current:5.84amp• Voltage: 240V• Solids handling:
35mm• IP Rating: 68
AW Stormwater Pump• 8 l/s@6m• Higher flow pump
for stormwater applications
• Cable length: 10m• Power Rating: 1.1kW• Current:• Voltage: 240V• Solids handling: 15mm• IP Rating: 68
AW Wastewater Pump
• 3 l/s@6m• Cutter pump for
stormwaterapplications
• Cable length:10m
• Power Rating:0.75kW
• Current:6.5A• Voltage: 240V• IP Rating: 68
Pump Options - Step 3WPAWXS0206 WPAWXS0506 WPAWXS1006
WPAWXW0306
AW Wastewater Pump
• 0.7 l/s@20m• Grinder pump for
medium sewerapplications
• Cable length: 10m• Current:6.84A• Voltage: 240V• Power Rating:
1.1kW
WPAWXW0720
AW Wastewater Pump
• 0.5 l/s@40m• High head pump
for pressure sewerapplications
• Cable length: 10m• Current:6.1A• Voltage: 240V• Power Rating:
0.9kW
WPAWXW0540
Stormwater Wastewater Manifolds
All manifolds come complete with watermarked fittings including:• Barrell Unions• Non-return and shut
off valves• Fitted into 50mm
PVC pressure pipe
WPAWSFM - SINGLEWPAWDFM - DOUBLE
• Built in overload circuit breaker (s)• Power size up to 1.5kW
(power output for pump up to 12a)• Auto test function• Pump rotation option• Real time clock with hour counter• Dry ryn, overload and short circuit protection• High level alarm included
Single/Dual Pump Controllers
WPAWSPC - SINGLEWPAWDPC - DOUBLE
AW Pump Curve
Control Equipment - Step 4High Level Alarm
Warning condition determined by a Float switch.Warning alarms are:Audio - BuzzerThe buzzer can be muted via the mute button. The visual alarms will remain on until the alarm condition is eradicated.
WPAWHLA
PumpOut Waterplex.indd 4 18/7/18 2:24 pm