    Ventilation Air Conditioning RefrigerationHeating

    22CInsideOUTSIDE

    HUMIDITY

    PROVIDED BYHEINEN & HOPMAN

    35 C

    90%

    productsAxial fans - HuA and VLA fans

  • Our mission:To ensure you the

    perfect climate indoors, regardless of theweather outside.

    AxiAl fAns

    With our wide range of fans, we can offer you the ultimate ventilation system for each situation. Our high quality fans are designed to with-stand all climate conditions. The fans comply with all requisite class and government regulations.

    Option

    The axial fans are available in different materials: - galvanized steel (standard) - primed and painted steel - marine corrosion-resistand aluminium - stainless steel The axial fans are used for the mechanical ventilation or areas such as engine rooms, cargo holds and pump rooms. The fans are available for both indoor and outdoor installations in standard formats or in special designs.

    ATEX The fans can optionally be supplied in explosion-proof design.

    Classification

    RMRS

    LES

    DNV-GL

    ABS

    BV

    RINA

  • HUA-s, HUA-l And VlA fAns

    ApplicationThe high-performance HUA-S / HUA-L (medium pressure) and VLA (high pressure, with outlet guide vanes) axial fans convey clean and slightly dusty air. Made of a highly corrosion-resistant aluminum alloy, the impellers ensure high efficiency and low noise levels. 30 fan types are available with flow rates up to 225.000 m/h and pressures up to 2,200 Pa. Comprehensive accessories and special designs allow easy adaptation to the most diverse requirements. Casing Made of steel, welded, with rolled flanges on both sides according to DIN 82330 and welded motor bracket. Optimal surface protection thanks to hot-dip galvanizing. Special coatings and casing thickness of 6 mm, 8 mm and 10 mm are available on request. HUA-S fans have a short casing. HUA-L fans have a long casing. The casings of the VLA type fans have outlet guide vanes. Casing orientation and direction of air delivery The standard direction of air delivery is impeller-motor. On request, the direction of air delivery for the fans can be changed in motor-impeller. impeller - HUA High-performance axial impeller. Hub and impeller blades made of a highly corrosion-

    resistant aluminium alloy (sea-water-proof). Blades are adjustable at standstill. Easy-to-assemble shaft/hub connection. Dynamically balanced. impeller - VlA Impeller is infinitely adjustable at standstill. Aero-foil section blades made of high-tensile aluminium cast alloy DN 315-1120. DN 1250 with corrosion-resistant polygon hub. Easy-to-assemble shaft/hub connection with taper lock bush. High-strength hollow-profiled blades of sheet steel. Dynamically balanced.

    Additional accessoiries

    Pair of mounting feet for floor or ceiling installation

    Inlet cone with protective grill Protective grill Counter flange galvanized standard

    thickness (for connection to ducts, etc.)

    Counter flange shop-painted (for welding to constructions)

    Plain flange galvanized or shop-painted

    Flexible connection of synthetic fabric with two flanges

    Inspection door in fan casing optional starting from DN 500

    Anti-vibration mounting for vertical intallation

    Casing extenstion

    To stand with our clients in the harshest environments

    Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

  • specifications HUA-s / HUA-l series

    Medium pressure - Axial fan with direct drive HUA-S / HUA-L series, DN 250 - DN 1600

    Size diameter

    DN

    Motor size

    d0 D2 Lk x n x d L X max

    L1 Weight (kg)

    250 71-80 252 355 325x12x14 180 58 300 10-20

    280 71-80 283 387 355x12x14 240 58 320 12-22

    315 71-80 317 422 390x12x14 240 58 400 14-23

    355 71-90 357 462 430x16x14 303 96 404 24-33

    400 71-100 402 507 475x16x14 303 145 505 34-48

    450 71-100 452 558 525x20x14 378 73 504 33-56

    500 80-132 502 608 575x20x14 378 112 630 36-100

    560 80-132 562 689 650x20x18 480 112 640 49-109

    630 80-132 632 759 720x20x18 555 112 740 67-111

    710 80-132 713 839 800x20x18 555 112 740 81-167

    800 90-160 804 932 890x24x18 585 138 780 108-225

    900 100-180 905 1032 990x24x18 675 154 900 144-287

    1000 100-200 1005 1135 1090x28x18 675 19 900 171-401

    1120 112-225 1128 1275 1230x28x24 810 91 1080 328-460

    1250 132-280 1258 1411 1360x28x24 810 285 1080 410-903

    1400 160-280 1410 1561 1510x32x24 1000 285 1670 485-978

    1600 160-315 1610 1762 1710x36x24 1200 322 2000 545-1333

    Weight depending on motor size

    HUA-S 250 - 1600 HUA-L 250 - 1250

    d0LK

    x n

    x d

    D2

    L1

    d0LK

    x n

    x d

    D2

    L X max

    d0LK

    x n

    x d

    D2

    L X max

    Air direction Air direction

    Dimensions in mm

  • 250mm, HUA

    2-pole [N = 2800 1/min] 4-pole [N = 1330 1/min]

    280mm, HUA

    2-pole [N = 2800 1/min] 4-pole [N = 1330 1/min]

    Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

    All indicated values for 400V/50Hz/3~. (60 Hz on request)

  • 315mm, HUA 355mm, HUA

    2-pole [N = 2830 1/min] 2-pole [N = 2875 1/min]

    400mm, HUA

    2-pole [N = 2890 1/min]

    Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

    All indicated values for 400V/50Hz/3~. (60 Hz on request)

  • 450mm, HUA

    2-pole [N = 2890 1/min] 4-pole [N = 1400 1/min]

    500mm, HUA

    2-pole [N = 2910 1/min] 4-pole [N = 1400 1/min]

    Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

    All indicated values for 400V/50Hz/3~. (60 Hz on request)

  • 560mm, HUA

    2-pole [N = 2920 1/min] 4-pole [N = 1440 1/min]

    630mm, HUA

    2-pole [N = 2940 1/min] 4-pole [N = 1440 1/min]

    Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

    All indicated values for 400V/50Hz/3~. (60 Hz on request)

  • Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

    710mm, HUA

    2-pole [N = 2940 1/min] 4-pole [N = 1445 1/min]

    800mm, HUA

    2-pole [N = 1445 1/min] 4-pole [N = 964 1/min]

    All indicated values for 400V/50Hz/3~. (60 Hz on request)

  • Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

    900mm, HUA

    4-pole [N = 1460 1/min]

    1000mm, HUA

    4-pole [N = 1465 1/min] 6-pole [N = 965 1/min]

    All indicated values for 400V/50Hz/3~. (60 Hz on request)

  • Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

    1120mm, HUA

    4-pole [N = 1465 1/min] 6-pole [N = 970 1/min]

    1250mm, HUA

    4-pole [N = 1475 1/min] 6-pole [N = 975 1/min]

    All indicated values for 400V/50Hz/3~. (60 Hz on request)

  • Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

    1400mm, HUA

    4-pole [N = 1475 1/min] 6-pole [N = 975 1/min]

    1600mm, HUA

    6-pole [N = 980 1/min] 8-pole [N = 730 1/min]

    All indicated values for 400V/50Hz/3~. (60 Hz on request)

  • Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

    specifications VlA series

    Medium pressure - Axial fan with direct drive VLA series, DN 315 - DN 1250

    Size diameter

    DN

    Motor size

    d0 D2 Lk x n x d X max

    L Weight (kg)

    315 71-80 317 422 390x12x14 125 240 23-29

    355 71-80 357 462 430x16x14 120 303 27-46

    400 71-100 402 507 475x16x14 170 303 34-48

    450 71-100 452 558 525x20x14 155 378 39-66

    500 71-112 502 608 575x20x14 220 378 45-109

    560 80-132 562 689 650x20x18 135 480 58-119

    630 80-132 632 759 720x20x18 40 555 74-121

    710 90-180 713 839 800x20x18 220 555 117-232

    800 100-200 804 932 890x24x18 250 585 168-301

    900 112-225 905 1032 990x24x18 290 675 221-417

    1000 132-250 1005 1135 1090x28x18 325 675 320-531

    1120 132-250 1128 1275 1230x28x24 190 810 402-575

    1250 132-280 1258 1411 1360x28x24 320 1080 786-1210

    L X max

    d0LK

    x n

    x d

    D2

    Air direction

    L X max

    d0LK

    x n

    x d

    D2

    Air direction

    160

    VLA 315 - 1120 VLA 1250

    Weight depending on motor size

    Dimensions in mm

  • Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

    315mm, VlA 355mm, VlA

    2-pole [N = 2875 1/min] 2-pole [N = 2885 1/min]

    400mm, VlA

    2-pole [N = 2890 1/min] 4-pole [N = 1400 1/min]

    All indicated values for 400V/50Hz/3~. (60 Hz on request)