AY/AE-A079E AY/AE-A099E Page SPECIFICATIONS ........................................................................................................................................... 2 EXTERNAL DIMENSIONS ............................................................................................................................... 3 WIRING DIAGRAMS ....................................................................................................................................... 4 ELECTRICAL PARTS ...................................................................................................................................... 5 MICROCOMPUTER CONTROL SYSTEM ...................................................................................................... 8 FUNCTIONS ................................................................................................................................................... 9 TROUBLESHOOTING OF THE CONTROL CIRCUIT .................................................................................. 17 REFRIGERATION CYCLE ........................................................................................................................... 21 PERFORMANCE CURVES .......................................................................................................................... 23 REFRIGERANT PIPE AINSTALLATION WORKS ......................................................................................... 24 DISASSEMBLING PROCEDURE ................................................................................................................. 25 REPLACEMENT PARTS LIST ....................................................................................................................... 29 TABLE OF CONTENTS SERVICE MANUAL S2915AYA099E/ SHARP CORPORATION SPLIT SYSTEM ROOM AIR CONDITIONERS INDOOR UNIT AY-A079E AY-A099E AE-A079E AE-A099E In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used. OUTDOOR UNIT MODELS
Transcript
Page 1: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

1

PageSPECIFICATIONS ........................................................................................................................................... 2EXTERNAL DIMENSIONS............................................................................................................................... 3WIRING DIAGRAMS ....................................................................................................................................... 4ELECTRICAL PARTS ...................................................................................................................................... 5MICROCOMPUTER CONTROL SYSTEM...................................................................................................... 8FUNCTIONS ................................................................................................................................................... 9TROUBLESHOOTING OF THE CONTROL CIRCUIT .................................................................................. 17REFRIGERATION CYCLE ........................................................................................................................... 21PERFORMANCE CURVES .......................................................................................................................... 23REFRIGERANT PIPE AINSTALLATION WORKS ......................................................................................... 24DISASSEMBLING PROCEDURE ................................................................................................................. 25REPLACEMENT PARTS LIST ....................................................................................................................... 29

TABLE OF CONTENTS

SERVICE MANUALS2915AYA099E/

SHARP CORPORATION

SPLIT SYSTEMROOM AIR CONDITIONERS

INDOOR UNIT

AY-A079EAY-A099E

AE-A079EAE-A099E

In the interests of user-safety (Required by safety regulations in somecountries) the set should be restored to its original condition and onlyparts identical to those specified should be used.

OUTDOOR UNIT

MODELS

Page 2: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

2

SPECIFICATIONS

ITEMS INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT

AY-A079E AE-A079E AY-A099E AE-A099E

Cooling capacity kW 2.1 2.6

Heatpump kW 2.4 3.0

Heating capacity

Moisture removal Liters/h 0.9 1.2

Electrical data

Phase – Single

Rated frequency Hz 50

Rated voltage range V 198 to 264

Rated voltage V 220 - 240

Rated current Cool A 3.2 - 3.1 4.1 - 3.9

Heat A 2.9 - 2.8 4.0 - 3.9

Rated input Cool W 680 - 720 890 - 920

Heat W 630 - 670 880 - 920

Power factor Cool % 97 - 97 99 - 98

Heat % 99 - 99 99 - 98

Compressor Type Hermetically sealed rotary type

Model 2PS134D5AA01 RH174VHET

Oil charge 270cc (SUNISO 4GDID) 300cc (DIAMOND MS56)

Refrigerant system Evaporator Louver fin and Grooved tube type(7mm tube)

Condenser Corrugate Fin and Grooved tube type

Control Capillary tube

Refrigerant volume 690g 730g

De-lce system Micro computer controled reverse sysetm

Noise level High dB(A) 33 43 38 43

(at cooling) Med. dB(A) 29 – 31 –

Low dB(A) 26 – 27 –

Fan system

Drive Direct drive

Air flow quantity High m3/min. 5.8 20 7.1 20

(at cooling) Med. m3/min. 4.9 – 5.3 –

Low m3/min. 4.3 – 4.4 –

Fan Cross flow fan Propeller fan Cross flow fan Propeller fan

Connections

Refrigerant coupling Flare type

Refrigerant tube size Gas, Liquid 3/8", 1/4"

Refrigerant pipe sets No. AZ-24H5E; 5m(16.4ft), AZ-24H7E; 7m(23ft)

Drain piping mm(Inches) O.D ø 18(45/64)

Others

Safety device Compressor: Overload protector(MRA98589) Compressor: Overload protector(Internal)

Fan motors: Thermal fuse

Fuse, Micro computer control

Air filters Polypropylene net (Washable)

Net dimensions Width mm 790 720 790 720

Height mm 270 535 270 535

Depth mm 155 236 155 236

Net weight kg 7 27 7 31

Note: The condition of star ( ) marked item are ‘IEC 378’.

Page 3: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

3

270

790155

Remote control

58 19.5

182 Length unit (mm)

EXTERNAL DIMENSIONS

Figure E-1. INDOOR UNIT for AY-A079E and AY-A099E

Figure E-2. OUTDOOR UNIT for AE-A079E and AE-E099E

430720775

14355

245

535

278

236228

20˚

58

Page 4: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

4

WIRING DIAGRAMS

Figure W-1. Wiring Diagram for AY-A079E and AY-A099E

Figure W-2. Wiring Diagram for AE-A079E

THERMISTOR (PIPE TEMP.)

THERMISTOR (ROOM TEMP.)

LOUVER MOTOR

1 2 3 4 5 6 CN5

CN3

CN101

BCN1CN2

BCN2CN201

RECEIVER & LED UNIT

SWITCH UNIT

THERMAL FUSE

TRANSFORMER

CONTROL BOARD UNIT 2

WH WH

RERE

FAN MOTOR CAPACITOR 400V 1µF

FAN MOTOR

R.P.M SIGNAL

BL

BL GR

RE

CN6

CN7

CN4CN1

SSR

RY2RY3

(B)(A)

(F)

(E)

NR VARISTOR

RYCONTROL BOARD UNIT 1

OUT

C.T.

INBK

OR

PU

BL250V

FUSE T2.5A

INDOOR UNIT TERMINAL BOARD 2

OUTDOOR UNIT

TERMINAL BOARD

EVAPORATOR

THERMAL FUSE

TERMINAL BOARD 1

POWER SUPPLY CORD

BR

BL

G(Y)

N

LG(Y)

G(Y)G(Y)

N

1

2

3

UNIT

TO

UNI

T CO

RD

BL

BR

BLBK BL BR GR

G(Y)

RE WH OR PU

: BLACK : BLUE : BROWN : GRAY : GREEN–YELLOW

: RED : WHITE : ORANGE : PURPLE

N5 7 1 2

1

2

3

5 3 1

I N D O O R U N I TT E R M I N A L B O A R D 2

T E R M I N A L B O R A D 1

UN

IT T

O U

NIT

CO

RD

O U T D O O R U N I T T E R M I N A L B O A R D

C O N D E N S E R

T H E R M A L F U S E

F A N M O T O R

V A L V E C O I L

F A N M O T O R C A P A C I T O R 4 0 0 V 1 . 5 µ F

C O M P R E S S O R M O T O R

M O T O R P R O T E C T O R

R U N N I N G C A P A C I T O R 3 7 0 V 2 5 µ F

B K

B K

W HR E

R

B LR E

B L

B L

B K

B L

R E

R E

G ( Y )G ( Y )

C

S

I

2

3

N

I

2

3

N

N

L

B K B L G ( Y ) R E W H

: B L A C K : B L U E : G R E E N - Y E L L O W : R E D : W H I T E

Page 5: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

5

ELECTRICAL PARTS

For Model AY-A079E and AE-A079EDESCRIPTION MODEL REMARKS SITECompressor 2PS134D5AA01 220/240V, 50Hz, 650W AEIndoor fan motor ML-A411 220/240V, 50Hz AYOutdoor fan motor ML-A592 220/240V, 50Hz AEIndoor fan motor capacitor – 400V, 1µF AYOutdoor fan motor capacitor – 400V, 1.5µF AERunning capacitor – 370V, 25µF AETransformer – Primary; AC 220V,50Hz AY

Secondary; AC16.1V, 50HzFuse 250V, 2.5A AYReverse valve MMB-26A 240V AEReverse valve coil RSV-10 – AE

For Model AY-A099E and AE-A099EDESCRIPTION MODEL REMARKS SITECompressor RH174VHET 220/240V, 50Hz, 800W AEIndoor fan motor ML-A411 220/240V, 50Hz AYOutdoor fan motor ML-A592 220/240V, 50Hz AEIndoor fan motor capacitor – 400V, 1µF AYOutdoor fan motor capacitor – 400V, 1.5µF AERunning capacitor – 370V, 25µF AETransformer – Primary; AC 220V, 50Hz AY

Secondary; AC16.1V, 50HzFuse – 250V, 2.5A AY

Reverse valve MMB-26A 240V AEReverse valve coil RSV-10 – AE

Figure W-3. Wiring Diagram for AE-A099E

I N D O O R U N I TT E R M I N A L B O A R D 2

T E R M I N A L B O R A D 1

UN

IT T

O U

NIT

CO

RD

O U T D O O R U N I T T E R M I N A L B O A R D

C O N D E N S E R

T H E R M A L F U S E

F A N M O T O R

V A L V E C O I L

F A N M O T O R C A P A C I T O R 4 0 0 V 1 . 5 µ F

C O M P R E S S O R M O T O R

M O T O R P R O T E C T O R

R U N N I N G C A P A C I T O R 3 7 0 V 2 5 µ F

B K

B K

W HR E

R

B LR E

B L

B L

B K

B L

R E

R E

G ( Y )G ( Y )

C

S

I

2

3

N

I

2

3

N

N

L

B K B L G ( Y ) R E W H

: B L A C K : B L U E : G R E E N - Y E L L O W : R E D : W H I T E

Page 6: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

6

Fig

ure

L-1.

Ele

ctro

nic

Con

trol

C

ircui

t D

iagr

am f

or A

Y-A

079E

and

AY

-A09

9E

+ –

+ – + –

+ –

+ –

+ –

+ –

19P

41

18P

42

17P

43

16P

44

15P

45

14P

46

13F

12R

ES

ET

33P

27

34P

26

35P

25

36P

24

37P

23

38P

22

39P

21

40P

20

41K

1

42P

17

43P

16

44P

15

45P

14

46P

13

47P

12

48P

11

49P

10

50P

07

51P

06

11C

K1

SM

8313

IC1

10C

K2

9A

GN

D

8P

30

7P

31

6P

32

5P

33

4P

50

3P

51

2P

52

1P

53

32 TEST 52P05

53P04

54P03

55P02

56P01

57P00

58GND

59VDD

60VR

61P57

62P56

63P55

64P54

31

30 OCSIN

OCSOUT

29 P60

28 P61

27 P62

26 GND

25 P63

24 P64

23 P65

22 P66

21 KH

20 P40

IC3

IC2

IC5

RP

M

4 3

3 2 1

3 2 1

4

15

1 1 2 3

5 4 3 2 1

1 2 3 4 5

1 2 3 4 5

7 6 1 8

7 6 1 8

55

1 2 3 4 5 6

L N N 1 2 3

3 5

2

2 2

73

C6

10

0µ10

v

C5

0.

1µ50

v

C4

47

µ25

v

C3

0.

22µ

50v

C16

0.

1µ50

vC

14

0.01

µ16

v

C14

10

00P

50

v

C15

0.

50vC

19

0.01

µ50

v

C21

10

00P

50

v

C7

0.1µ

50v

C23

10

00P

50

v

C17

10

00P

50

v

C13

10

00P

50

v

C8

10

µ10

v

(C10

2)

0.1µ

25v

C101

33

µ10

v

C11

10

µ16

v

C10

10

µ16

v

C22

10

00P

50

v

C2

22

00µ

35v

C1

0.

1µ25

0vA

CN

R

R2

22

k

R30

10

k

R22

1k

R4

6.

8k

R7

3.

3k

R23

33

k

R19

10

k

R18

15

kF

R17

15

kF

R5

2.

7k

R24

4.

7k

R21

10k

R20

10k

10k

10k

10k

10k

R31

R32

R33

R34

R35

R36

R37

R38

R39

22k(

F)

22k(

F)

22k(

F)

NONE

22k(

F)

R25

1.

2k

R29

330

R41

10k

R40

10k

R28

680

R26

68

0

NC

NC

NC

NC

NC

NC

NC

R3

22

k

R6

47

0

1/2w

RY

1R

Y3

RY

2D

5

OU

T

5V12

V

OU

T

7812

D1

D3

D4

D2

CD

AB

1311

SS

RS20

1D01

L

FU

SE

CT

2.5A

250

V

CN

R3

C12

0.0

1µ 2

50vA

C

FA

N M

OT

OR

C

AP

AC

ITO

R

TH

ER

MA

L P

RO

TE

CT

OR

A

INO

UT

RY

1

E

RY

2

CN

R1

CN

R2F

RY

3

PO

WE

R

SU

PP

LY

TE

RM

INA

L B

OA

RD

3P

GR

EE

N/Y

ELL

OW

EA

RT

H L

INE

NE

UT

RA

L LI

NE

CO

MP

RE

SS

OR

VA

LVE

CO

IL

OU

T D

OO

R

UN

IT

FA

N M

OT

OR

BC

N2

BC

N1

CN

2

CN

2

Q3

3

12

CN

112

V

TR

12VQ

22

13

IC4

9

8

12V

BC

N1

SS

R

CN

101

CN

201

CN

7

CN

6

PH

OT

O D

ET

EC

TO

R U

NIT

AU

X.

(TE

ST

RU

N)

(YE

LLO

W)

LED

102

(RE

D)

LED

101

2 3

BC

N2

CN

3

CN

4

BC

N1

BC

N2

LOU

VE

R M

OT

OR

FU

NC

TIO

N12

H /

24H

IC1

PIN

NO

.19

(P

41)

SY

MB

OL

JP10

AY

-A07

9EX

NO

NE

DE

ICE

B

DE

ICE

A

15

(P45

)

JP5

14

(P46

)

JP4

SW

EA

T

ON

/OF

F

8 (P

30)

JP6

D. F

AN

OFF

OFF

/ON

17

(P43

)

JP9

X N

ON

E

OFF

WID

EH

3/5m

in.

16

(P44

)

JP7

X N

ON

EX

NO

NE

X N

ON

E

WIR

ELE

SS

C

HA

NG

/ N

OR

MA

L

5 (P

33)

JP2

X N

ON

EX

NO

NE

NO

TE

:

1.: T

ES

T P

OIN

T

5V

BC

N2

BC

N1

D9

5V

D8�

5V

5V 5V

5V

5V5V

5V

5V

5V

5V

12V

TE

ST

D7

R14

2k

(F)

R13

10

k(F

)R

16

13.7

k(F

)C

9 16

V

220µ

C20

50

V

1000

P

TH

1

RO

OM

TE

MP

.

15k(

25˚C

)

TH

2

PIP

E T

EM

P.

15k(

25˚C

)

BZ

5V

5V

10V

NC

NC

NC

NC

NC

NC

1 2 3 4

8 7IC

66 5

JP14

DE

. FA

N B

12H

/24H

SW

EA

T

PR

EH

EA

T

FA

N L

FA

N M

FA

N H

MO

DE

L B

MO

DE

L A

WIR

ELE

SS

RPM

PLU

SE

DE

ICE

B

DE

ICE

A

D. F

AN

OFF

OFF

WID

EH

DE

. FA

N A

FR

EE

ZE

B

FR

EE

ZE

A

PO

WE

R O

N

JP13

JP12

JP11

JP9

JP7

JP5

JP4

Q1

OC

S

8MH

z

3

3

3

2

11 1

2

2

JP10

JP6

JP3

JP1

JP2

R10

R9

R8

R12

R11

JP8

CN

5

ININ

TH

ER

MA

L F

US

E

GN

DG

ND

2. N

ot s

peci

fied

is 1

/5w

US

E

RP

M

PLU

SE

1/

3 7 (P

31)

JP3

US

E

PR

EH

EA

T

OF

F/O

N

6 (P

32)

JP1

FA

N L

4 (P

50)

R10

140k

(F)

FA

N M 3

(P51

)

R9

FA

N H

2 (P

52)

R8

22k(

F)

24.9

k(F

)

MO

DE

L B 1

(P53

)

R12

133k

(F)

MO

DE

L A 64

(P

54)

R11

X N

ON

E

DE

. FA

N

B 33

(P27

)

JP14

X N

ON

E

DE

. FA

N

A 34

(P26

)

JP13

X N

ON

E

FR

EE

ZE

B 35

(P

25)

JP12

X N

ON

E

FR

EE

ZE

A 36

(P

24)

JP11

X N

ON

E

PO

WE

R O

N

ON

/OFF

40

(P20

)

JP8

US

E

AY

-A09

9EX

NO

NE

X N

ON

EX

NO

NE

X N

ON

EU

SE

US

EU

SE

US

E14

0k(F

)15

k(F

)1.

87k(

F)

15k(

F)

107k

(F)

X N

ON

EX

NO

NE

X N

ON

EX

NO

NE

X N

ON

EU

SE

+ –

R15

2.

7k(F

)

Page 7: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

7

Figure L-2. Printed Wiring Board

The

rmis

tor

CN

7

CN

6

CN

101

CN

201

Indo

or fa

n m

otor

(R.P

.M. S

igna

l)In

door

fan

mot

or

Ter

min

al b

oard

L

Ter

min

al b

oard

" 1

"

Tra

nsfo

rmer

BC

N2

BC

N1

TR

AN

SF

OR

ME

R

Louv

er m

otor

Fan

mot

or c

apac

itor

Fan

mot

or c

apac

itor

250V

2.5

A

FUSE

IN OUT

RY

1

RY

3

RY

2

DP

WB

FAJB

K0(

P)

QP

WB

FB

252J

BE

0(P

)R

3

R26 R41

R40

C23

C13

R28IC2 R29

JP46

D9

CN6

C22

C21C20

R20R15R16R21

R39

R25

OUT

IN

81

11 3

3

QPWBFB252JBE0(C)

DPWBFA JBK0(C)R

2

C2

D5

CNR3

C8

C7

C12

C4

C9

IC3

JP49

CT

JP 27

JP42

CN3

CN5

CN4

JP44

JP43

OSC

IC5

JP9

JP48

JP47

R11

R12

R8 R9 R35

C15

R10

C101

SW20

1

TEST

RU

NAU

X.

SW20

2

CN101CN201

LED1

01LE

D102

RECE

IVER

UNI

T

QPW

BFB1

24JB

E0

QPW

BFA6

52JB

E0

OPE

RATI

ON

(RED

)TI

MER

(Y

ELLO

W)

JP3

JP2

JP6

R36

R34

R32

R31

MO

DEL

A

MO

DEL

B

FAN

H

FAN

M FAN

L

WIR

ELES

SL

D. F

AN O

FF

12H / 24H

OFF WIDEH

DEICE B

DEICE A

RPM

PUL

SE

SWEA

T

CN7

C5

C3

CN1

FAN

LOUV

ER

IN

OUT

MOT

OR

RPM

SIG

NAL

THER

MIS

TOR

MOT

OR

GRA

Y

(B)

SSR

R6

D4

1

1 8

2572

7

13

11

511

31 1

145

8

19

52

64

33

16

9

8

1IC

4D2

D1

CN2

BCN1(TRANSFORMER)

L

C1NR

FAN MOTOR CAPACITOR

(D)CNR1

CNR2

VALVE

PURPLE

ORANGE

OUT DOOR FAN MOTOR(F)

(E)2

COIL

(C1)

(A1)

BLUE(FAN MOTOR CAPACITOR)

D3

15

51

1

11 1

16

3

35

JP38JP39

IC1

POWER ON

FREEZE A

FREEZE B

DE.FAN A

DE.FAN B

JP8

JP11

JP13

JP14

R7

R23

R24

JP50

JP33

JP4JP5JP7

R19JP10

C19C16

R4

Q3Q2

R22

JP12

JP51

BCN2 JP35

JP41

JP40

R38R37

R33

JP1PREHEAT

JP34

C14

C18

JP37

JP36

IC6

C17

FPW

BFA1

34JB

K0

FPW

BFA0

13JB

K0

FSGY-A141JBK0

3 1Q1

C6

C10

R30

R18

R17

C11

R5

20

113 5

R14

R13

D7

D8

GND

12V

GND

5V

12V

3

DIP

DIP

Page 8: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

8

Pin Terminal Input

No. Name Output Function

33 P27 IN MODEL 4

34 P26 IN MODEL 3

35 P25 IN MODEL 2

36 P24 IN MODEL 1

37 P23 IN SWITCH AUX.

38 P22 IN SWITCH TEST RUN

39 P21 IN –

40 P20 IN POWER ON

41 KI IN WIRELESS SIGNAL

42 P17 OUT LED OPERATION

43 P16 OUT LED TIMER

44 P15 OUT –

45 P14 OUT –

46 P13 OUT (VALVE COIL)

47 P12 OUT (OUT DOOR FAN)

48 P11 OUT RY1

49 P10 OUT SSR

50 P07 OUT LOUVER MOTOR

51 P06 OUT LOUVER MOTOR

52 P05 OUT LOUVER MOTOR

53 P04 OUT LOUVER MOTOR

54 P03 OUT –

55 P02 OUT –

56 P01 OUT –

57 P00 OUT –

58 GND IN 0V

59 VDD IN 5V

60 VR IN 5V

61 P57 IN (CURRENT LEVEL)

62 P56 IN TH1

63 P55 IN TH2

64 P54 IN MODEL A

Microcomputer (IC1)The microcomputer is a CMOS, one chip, 8-bit microcomputer.Microcomputer port allocation is as follows.

Pin Terminal Input

No. Name Output Function

1 P53 IN MODEL B

2 P52 IN FAN H

3 P51 IN FAN M

4 P50 IN FAN L

5 P33 IN WIRELESS

6 P32 IN PREHEAT

7 P31 IN PRM PLUSE

8 P30 IN SWEAT

9 AGND IN 0V

10 CK2 IN OSILLATION

11 CK1 IN OSILLATION

12 RESET IN RESET

13 F OUT BUZZER

14 R46 IN DEICE A

15 R45 IN DEICE B

16 R44 IN COMP. OFF WIDTH

17 R43 IN DEHUM. FAN OFF

18 R42 IN TEST 1

19 R41 IN –

20 R40 IN –

21 KH IN PRM SIGNAL

22 P66 IN –

23 P65 IN –

24 P64 IN –

25 P63 IN AC CLOCK

26 GND IN 0V

27 P62 IN –

28 P61 OUT EEPROM CLOCK

29 P60 IN EEPROM DATA

30 OSC IN –

31 OSC OUT –

32 TEST IN –

Page 9: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

9

FUNCTIONS

1. Temperature control characteristic1-1 COOL operation

In the “COOL” mode, the thermostat circuit iscontrolled by four thermostat lines (C1 thru C4).

1-3 HEAT operationIn the “HEAT” mode, the thermostat circuitis controlled by six thermostat lines (H01 thruH4).

Figure Y-1

1-2 DRY operationIn the “DRY” mode, the thermostat circuit iscontrolled by three thermostat lines (D1 thru D3).

Figure Y-3

2. Operation modes2-1 COOL operation

The compressor turns on or off, at the thermostatlines C3 and C4. The outdoor fan motor is alsocontrolled with the compressor.

Figure Y-4

Figure Y-2

Preset temperature (˚C)

H4H3H2H1H02H01

17

1921222426

313335363840

18 32

Roo

m te

mpe

ratu

re(˚

C)

Roo

m te

mpe

ratu

re

Preset temperature

Room temperature transition

C3

C4

States 1 & 3 : Compressor ON State 2 : Compressor OFF

1

2

3

18 32

C1

C2

C3

C4

17.5

18.5

19.5

20.5

31.5

32.5

33.5

34.5

Preset temperature (˚C)

Roo

m te

mpe

ratu

re (

˚C)

Roo

m te

mpe

ratu

re(˚

C)

Preset temperature (˚C)18 32

D1

D2

D3

17.5

18.5

19.5

31.5

32.5

33.5

Page 10: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

10

Figure Y-6

2-4 Fan only operationThe indoor fan motor always turns on.

3. Fan speedFan speeds are given by the indoor fan motor, "H",“M”, “L”, “UL” and "D" which are available in thefollowing operation mode.

Table Y-2

FAN Switch HEAT COOL FAN ONLY

HIGH H M M

LOW M L L

SOFT L UL UL

2-3 Heat operationThe compressor turns on or off, at State 2 , turnson continuously at State 1 & 3 .

Figure Y-5

Table Y-1

Compressor Fan Speed

Cooling zone ON “UL”

Dehumidifying ON “D”

zone

Circulating OFF “D” or OFFzone

2-2 DRY operation On the switch on, the compressor always startsto operate for 2 minutes with fan speed “D”(slower than “UL”).The microcomputer reads the room temperature2 minutes after this first compressor operation.This room temperature is set as the presettemperature automatically.The preset temperature ranges from 18˚C to32˚C. When the room temperature is below 18˚C,the preset temperature is set to 18˚C, and whenthe room temperature is over 32˚C, the presettemperature is set to 32˚C.Dry operation is divided into three zones (Coolingzone, Dehumidifying zone and Circulating zone)by thermostat lines (D1 to D3), and thecompressor and the fan motor are controlled ineach zone as shown in Table Y-1.

Roo

m te

mpe

ratu

re

Preset temperature

Room temperature transition

D3

D2

D1

States 1 & 5 : Cooling zone States 2 & 4 : Dehumidifying zone States 3 : Circulating zone

3

4

5

1

2

Roo

m te

mpe

ratu

re

Preset temperature

Room temperature transition

States 1 & 3 : Compressor ON States 2 : Compressor OFF/(ON) (Hot-keep function)

H1

H2

31

2

Page 11: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

11

Figure Y-9

Table Y-3

Figure Y-8

Figure Y-7

5. Preheat air flowThis function is intended to prevent cold air from beingdischarged when the heating operation starts or whendefrosting.When the indoor pipe temperature is below 29˚C at thebegining of the heat operation or after defrosting, theindoor fan motor stays.When the indoor pipe temperature gets higher than29˚C, the fan motor is turned on at speed “UL” aftercompensation of starting.When the indoor pipe temperature exceeds 35˚C, thespecified fan speed is restored. When the indoor pipetemperature falls below 30˚C, the fan speed shiftsdown to “UL”. And, when the indoor pipe temperaturefalls below 24˚C, the fan motor turns off. Then, over29˚C , it turns on again at speed “UL”.

4. Hot-KeepThis function automatically controls the on-off operationof the indoor fan motor in accordance with the on-offoperation of the compressor during the heatingoperation, thereby preventing the air conditioner fromdelivering a cold air when the compressor is off.When the room temperature exceeds the thermostatline “H1”, the compressor is turned off, and the indoorfan motor is turned off after rotating at “UL” for 30seconds.3 minutes after turning off the compressor, thecompressor is turned on for 3 minutes. (belowthermostat line H01). While over H01, the compressoris off.At 10 seconds after turning on the compressor, theindoor fan motor is turned on.The next compressor OFF time is for 3, 8 or more than8 minutes according to the room temperature (the timeincreases with a rise of room temperature) when 3minutes elapse after turning on the compessor.

6. Overheating protection systemWhen overloading occurs during the heating operation,this system controls the outdoor fan motor according tothe indoor pipe temperature to prevent the overloadingof the compressor and restrain the rise in high pressure.When the indoor pipe temperature exceeds U1˚C, theoutdoor fan motor is turned off, and when the indoorpipe temperature falls U2˚C, the outdoor fan motorturns on.If 3 minutes elapse after turning off outdoor fan motor,the outdoor fan motor is turned on, when the indoorpipe falls U1˚C,

Compressor ON

OFF

Indoorfan motor

30sec.

time

ULON

OFF

3 min.(Notes)3 min.

10sec.

UL

30sec.

10sec.Thermo off

3 or 8 or 15min.

(Notes)

Notes: Compressor is off when compressor OFF time is 15 minutes.

Pip

e te

mpe

ratu

re(˚

C)

24

2930

35

OFFUL UL ULOFFPreset

Fan speed

OFF OFF

ON

ONU1

U2

U1

U2

Within 3 minutes Over 3 minutes

MODELS

AY-A099E

AY-A079E

M L UL

U1

U2

U1

U2

53˚C

Fan Speed

Line

49˚C

53˚C

49˚C

53˚C

49˚C

54˚C

50˚C

53˚C

49˚C

54˚C

50˚C

Page 12: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

12

7. Current controlThis system, in order to prevent overcurrent duringheating operation, controls the outdoor fan motor andchanges the indoor fan motor speed by detecting totalcurrent.When the current exceeds P2, the outdoor fan motor isautomatically turned off, and when the current fallsbelow P4, the outdoor fan motor is turned on.When the current exceeds P3 and the indoor fan speedshifts down because of cold air (5. Preheat air flow), thechanges in the indoor fan speed shifts up as follows,from "off" to "UL", or from "UL" to "L". And when thecurrent falls bellow P5, the indoor fan speed shift up iscanceled.

Figure Y-10

8. Freeze preventiveWhen the indoor pipe temperature falls below -1˚Cduring cool operation or dry operation, the compressoris turned off.

9. DefrostThe defrost timer (integrating the operation time ofcompressor) counts time with microcomputer duringheat operation.Frost of outdoor pipe is estimated by indoor pipetemperature (TH2), room temperature (TH1), indoorfan speed and operation state of compressor.In the defrost operation, first the compressor is turnedoff, the fan speed is set to “UL” and the outdoor fanmotor is turned off.30 seconds later the indoor fan motor is turned off, 50seconds later the reverse valve is turned off, and 60seconds later the compressor is turned on.In the end of defrosting, the compressor is turned off,the outdoor fan motor is turned on, 50 seconds later thereverse valve is turned on, 60 seconds later thecompressor is turned on, starting heat operation.At this time, the indoor fan motor is turned off or the fanspeed is set to “UL” if preheat air flow function iseffective.

Figure Y-11

Figure Y-12

10. Delayed operation of the reverse valveWhen the heat operation is shut down or the operatingmode is switched from heat to cool or dry, or vice versa,the reverse valve is switched after 3 minutes.

11. Test runIf the “TEST RUN” button in the unit is pushed duringsuspension of operation, cool test operation starts. Atthis time, the fan speed is set to “AUTO”.If this button is pushed during operation, the testoperation starts in current operation mode. Theoperation LED (red) flickers during test run.In cool and heat mode continuous compressor onoperation is performed. In dry mode the operation is indehumidifying zone. In fan only mode the indoor fanmotor runs continusly.

12. Timer12-1 24-HOUR PROGRAMMABLE ON/OFF TIMER

ON-TIMER or OFF-TIMER can be independentlyprogrammed. When the unit operates during onehour after the OFF-time is set, thermostat settingis automatically shifted (+1˚C in cool operationand dry operation, -3˚C in heat operation, 16˚C -32˚C).When the ON-timer is set in heat operation andcool operation, operation starts before 0 to 30minutes(depends on the room temperature) sothat preset temperature is obtaind at set time.

12-2 ONE-HOUR TIMERWhen ONE-HOUR timer is set, the unit turns offautomatically after one hour. The one hour timeroperation has priority over other time operation,such as the TIMER ON and TIMER OFF. If theONE-HOUR TIMER button is pressed againduring operation, the unit will operate additionallyfor another one hour.

Outdoor Fan motor OFF

Indoor Fan motor Shift UP

Compressor OFF

Time

Inpu

t cur

rent

Current transition

P1 5.3A 6.9A

P2 4.5A 6.1A

P3 4.0A 5.4A

P4 3.4A 4.6A

P5 2.6A 4.2A

AY- A079E

AY- A099E

Defrost start

Compressor

ReverseValve

OutdoorFan Motor

IndoorFan Motor

Preheat AirFlow Control

30sec.

MAX. 9min.

50sec. 10sec.

60sec.

ON

OFF

ON

OFF

ON

OFF

ON

OFF

50sec. 10sec.

UL

Switch ON

Heating Heating Heating

Min. 40min.

Max. 11min.

Min. 30min.

Max. 11min.

DefrostDefrost

Page 13: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

13

13. Automatic air conditioningWhen automatic air conditioning is selected, theoperation mode and preset temperature are setautomatically according to the room temperature onstarting operation.

Table Y-4

15. Outputs in each operation mode

Table Y-5

16. Power on startIf the connecting wire "POWER ON" (JP8) is cut on thePWB ass'y, when the power is supplied by turning ona circuit breaker, the air conditioner automaticallystarts of operation in "AUTO".(Refer to Figure L-2. Printed Wiring Board.)

17. AUTO RESTARTPower failure occurs during operation, the unit willretart in the same operation mode as before afterpower recovery.(Refer to Figure L-2. Printed Wiring Board.)

18.Test mode18-1 TEST 1 (For control circuit operation checking)

Make terminals 1 and 2 of connector CN4 short-circuited and supply the power.Hereby the timer's period becomes shortened.In this test mode, the control times are shortendas follows.

The operation LED flicker's period not

in Test run shortenedThe protector timerThe defrost timer

Other controls; 1/60 (ex.; 3 min. to 3 sec.)

18-2 TEST 2 (For output of each operation checking)Keep pushing both the buttons, "AUX." and"TEST RUN", and supply the power, the systemwill go to the test 2 mode. In this mode, theoutput of operation is switched by pushing the"TEST RUN" button in the unit or the "OI" buttonin the remote controller. Use the "AUX." buttonto back to step 1.Normal outputs are shown in Table Y-6 and Y-7.

14. Automatic fan speedWhen the automatic fan speed is selected in cool orheat operation, the fan speed is automatically changedby the thermostat lines C1 to C3 in cool operation, andH1 to H4 in heat operation.

a.COOL operation

Room temperature at operation start

Operation Mode

Preset Temperature

Above 28˚C

Below 21˚C

26˚C26˚C 28˚C24˚C 26˚C21˚C 24˚C

25˚C24˚C

Room temperature at operation start

23˚C

COOL

DRY

HEAT

ONOFFONOFF

ON

ON

ONOFFOFF

ON ON OFFOFF ON OFFON ON ONOFF ON/UL/OFF ON

ON UL/OFF ON

OFF OFF OFF

ON

L/ULUL/D

OFF D/OFFOFF ON

OFFOFFOFFOFF

Mode Compressor Outdoor Fan Motor

CoolingCirculatingNormal

Preheat Air Flow Control

ON Defrost

FAN ONLY

Indoor Fan Motor

Valve Coil

C O O L

H E A T

D R Y

Cooling

CirculatingDehumidiflying

Figure Y-13

b. HEAT operation

Figure Y-14

Roo

m te

mpe

ratu

re

Preset temperature

Room tempera tu ret rans i t i on

C3

C2

C1

States 1 & 5 :"M"States 2 & 4 : "L"States 3 : "UL"

3

4

5

1

2

Roo

m te

mpe

ratu

re

P rese t tempera tu re

Room temperature t ransi t ion

States 1 & 7 : "H" States 2 & 6 : "M" States 3 & 5 : "L" States 4 : "L"/"UL"/OFF H1

H2

1

H4

H3

6

5

4

7

2

3

Page 14: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

14

19.Diagnosis procedureWhen indoor fan motor is out of order or compressor lock occurs, the compressor, inddor fan motor, outdoor fanmotor, and louver are all stopped and the operation LED(red) turns on or off syncronously with the timimg of thetimer LED.When the thermistor for room temperature or pipe temperature is open or short state, the operation LED turns onor off syncrnoously with the timing of the timer LED by pushing continously for more than three seconds both"TEST" button and "AUX." button.

Timing chart of Timer LED and Operation LED of DIAGNOSIS PROCEDURE.When "OI" button the remote controller or "AUX." button in the unit is pushed, the unit is free from DIAGNOSISPROCEDURE.

Indoor fan motor

Comp.-lock

Thermistor short state

Thermistor open state

Timer LED

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Operation LED

Operation LED

Operation LED

Operation LED

1sec. 1sec.

4sec.

Page 15: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

15

Table Y-6 [AY-A079E]

Step

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

Output for outdoor unit Lamps

RED YELLOW

Indoor Fan motor

Louver

OFF

Compressor

Reverse Valve

Outdoor Fan Motor

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF OPEN

ON D OFF Flickering

OFF H OFF

ON ON L CLOSE

ON OFF D OFF

OFF UL OFF

OFF OFF H OFF

OFF OFF M OFF

OFF OFF L OFF

OFF ON OFF OFF

OFF OFF OFF OFF

ON OFF OFF OFF

OFF OFF OFF OFF

ON ON OFF OFF

ON ON OFF OFF

ON OFF OFF OFF

OFF OFF OFF OFF

OFF OFF OFF OFF

OFF OFF OFF OFF

ON OFF OFF OFF

OFF ON OFF OFF

ON ON OFF OFF

23 OFF OFF OFF OFF OFF

(Back to step 1)

ON

1 2

3

4

1

2

3

: 7˚C Room temp. 42˚C ON : 7˚C (Room temp.) or (Room temp.) 42˚C OFF

: –2˚C Pipe temp. 42˚C ON : –2˚C (Pipe temp.) or (Pipe temp.) 42˚C OFF

: 0.1V (P57 input voltage) 0.45V ON : 0.1V (P57 input voltage) or (P57 input voltage 0.45V) OFF

4 : When Power on start is effective, Timer LED(yellow) is ON.

Page 16: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

16

Table Y-7[AY-A099E]

Step

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

Output for outdoor unit Lamps

RED YELLOW

Indoor Fan motor

Louver

OFF

Compressor

Reverse Valve

Outdoor Fan Motor

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF OPEN

ON D OFF Flickering

OFF H OFF

ON ON L CLOSE

ON OFF D OFF

OFF UL OFF

OFF OFF H OFF

OFF OFF M OFF

OFF OFF L OFF

OFF ON OFF OFF

OFF OFF OFF OFF

ON OFF OFF OFF

ON OFF OFF OFF

ON ON OFF OFF

ON OFF OFF OFF

ON OFF OFF OFF

OFF OFF OFF OFF

ON OFF OFF OFF

ON OFF OFF OFF

OFF ON OFF OFF

ON OFF OFF OFF

OFF ON OFF OFF

23 OFF OFF OFF OFF OFF

(Back to step 1)

ON

1 2

3

1

2

3

: 7˚C Room temp. 42˚C ON : 7˚C (Room temp.) or (Room temp.) 42˚C OFF

: –2˚C Pipe temp. 42˚C ON : –2˚C (Pipe temp.) or (Pipe temp.) 42˚C OFF

: 0.1V (P57 input voltage) 0.45V ON : 0.1V (P57 input voltage) or (P57 input voltage 0.45V) OFF

4 : When Power on start is effective, Timer LED(yellow) is ON.

Page 17: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

17

TROUBLESHOOTING GUIDE OF CONTROL CIRCUIT

measure the secondary voltage of transformer.

YES

NO

YES

NO

The machine does not function at all with remote controller and switches on the indoor unit.

Using a tester, measure the voltage between terminal " 1 " and " 2 " of connector CN2 on PWB ass'y.

Is the measured value approx. 16.0 Vac ?

Replace the PWB with a new one.

Is the 2.5A fuse down ?

Replace the fuse and varistor with new ones.

Replace the ftransformer with a new one.

Page 18: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

18

YES

NO

NO

YES

The machine does not function with remote controller

Push butt "OI" on on the wireless remote controller.

Is transmitting indicator of the remote

controller active ?

Is indicator lamp of indoor unit proper ?

Replace the PWB with a new one.

Does beep sound from the indoor unit ?

Does connector CN101 & CN6 connect

in place ?

Using a tester, measure the voltage between terminals of resistor R15 on the PWB ass'y.

Push the button "OI".

Are batteries of the wireless remote controller

proper ?

Replace the batteries with new ones.

Replace the wireless remote controller.

When the signal is received, does the voltage

change ?

Replace the PWB with a new one.

PWB is normal. Inspect the outdoor unit.

NO

YES

YES

NO

YESReplace the display unit with a new one.

Connect the connector properly.

NO

YES

NO

Page 19: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

19

The room is not cooled at all or not cooled. The compressor does not operate.

Measure resistances of TH1 and TH2.

The control circuit is normal. The compressor may be defective. The running capacitor may be defective. Refrigerant may be leaked. The outdoor fan motor may be defective. The outdoor fan motor capacitor may be defective.

Push the button "TEST RUN" on the indoor unit, and wait 3 minutes.

Is the voltage between terminal "N" and

"1" of the terminal board the power supply voltage ?

Are the resistances conformed Fig. 1 ?

Replace the thermistor ass'y with a new one.

NO

YES

YES

NO

Replace the PWB ass'y with a new one.

0

20

40

60

80

100

120

140

160

180

K

0 10 20 30 40˚C-10

CHARACTERISTIC OF TH1 & TH2

Fig. 1

25˚C 15KUsing a tester, measure voltage at

the terminals on the terminal board.

Page 20: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

20

The room is not heated at all or not heated. The compressor does not operate.

The control circuit board is normal. Refrigerant may be leaked. The running capacitor may be defective. The outdoor fan motor may be defective. The outdoor fan motor capacitor may be defective. The compressor may be defective. The thermistor may be defective.

Is the voltage between terminal "N" and

"1" of the terminal board the power supply voltage ?

NO

Replace the PWB ass'y with a new one.

Push the button of "TEST RUN" on the indoor unit, and wait 3 minutes.

Using a tester, measure voltages at the terminals on the terminal board.

Select HEAT MODE with remote controller. And then start operation.

Is the voltage between terminal "N" and

"2" of the terminal board the power supply voltage ?

Is the voltage between terminal "N" and

"3" of the terminal board the power supply voltage ?

YES

YES

YES

NO NO

NO

Page 21: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

21

REFRIGERATION CYCLE

Figure R-1. Refrigeration Cycle for AY-A079E and AY-A099E

Figure R-2. Flow of Refrigerant for AY-A079E and AY-A099E

At Cooling At Heating

Indoor unit

Outdoor unit

Flare coupling

Evaporator

Strainer

Condenser

Accumulator

Compressor

Reverse valve

Check valve

Capillary tube B

Strainer

Capillary tube A

Flare coupling Flare coupling

Flare coupling

1

4 2

3

S

S

Page 22: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

22

Cycle temperature and service port pressure

ISO Cooling and Heatpump condition(at 220V REFRIGERANT PIPE LENGTH 7.5 m)

Dimension of Capillary tube

ISO Cooling and Heatpump condition

O.D. I.D. LCapillary tube ACapillary tube B

MODEL

ø 2.7 ø 1.5ø 1.4

800600ø 2.7

O.D. I.D.AE-A079E AE-A099E

Lø 2.7 ø 1.5

ø 1.5700700ø 2.7

AY-A079E

78˚C 65˚C43˚C 2˚C11˚C 33˚C8˚C 1 ˚C

0.52MPa 1.49MPa

AY-A099E

80˚C 84˚CCooling Heating Cooling Heating

44˚C 1˚C11˚C 35˚C6˚C 3 ˚C

0.47MPa 1.75MPaService port pressure

ModelNO. Condition

1234

Gauge pressure

Indoor side Outdoor sideTemperature (˚C) Temperature (˚C)Relative humididity (%) Relative humididity (%)

27 47 35 4020 37 7 87

CoolingHeating

Page 23: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

23

PERFORMANCE CURVES

Figure P-1. At Cooling for AY-A079E Figure P-2. At Heating for AY-A079E

1.5

2.0

2.5

3.0

3.5

(KW

)

1000

500

15

14

Inpu

t(W

)

13

12

11

10

9

8

7

Outside air temp.(˚C)

Out

let a

ir te

mp.

(˚C

)

3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 0

15001.0

2.0

2.5

3.5

4.0

(KW

)

1000

500

50

0

Inpu

t(W

)

Outside air temp.(˚C)

Out

let a

ir te

mp.

(˚C

)

3.0

1.5

45

40

35

30

25

20–10 –8 –6 –4 –2 0 2 4 6 8 10

5100

6800

8500

10200

11900

Coo

ling

capa

city

(B

TU

/h)

3400

13600

Coo

ling

capa

city

(B

TU

/h)

11900

10200

8500

6800

5100

Indoor air temp. : 27˚C

: 47RH%: Hi

Indoor humidityIndoor fan speedPower source : 220V 50Hz

Indoor air temp. : 20˚C: HiIndoor fan speed

Power source : 220V 50Hz

Page 24: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

24

Figure P-3. At Cooling for AY-A099E Figure P-4. At Heating for AY-A099E

REFRIGERANT PIPE INSTALLATION WORKSRefrigerant pipe length and level difference between the indoor and outdoor units.

The shorter refrigerant pipe, the highter the machine capabillity. Keep the pipeline as short as possible.

Indoor air temp. : 27˚C

Indoor humidity : 47RH%Indoor fan speed : Hi

5100

6800

8500

10200

11900

Coo

ling

capa

city

(BT

U/h

)

1000

1.5

2.0

2.5

3.0

3.5

(KW

)

500

15

14

Inpu

t(W

)

13

12

11

10

9

8

7

Outside air temp.(˚C)

Out

let a

ir te

mp.

(˚C

)

3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 0

Power source : 50Hz, 220V

Indoor air temp. : 20˚CIndoor fan speed : Hi

6800

5100

3400

8500

10200

11900

13600

Coo

ling

capa

city

(BT

U/h

)1000

4.0

3.5

3.0

2.5

2.0

1.5�

1.0

(KW

)

500

0

Inpu

t(W

)

50

45

40

35

30

25

2-

Outside air temp.(˚C)

Out

let a

ir te

mp.

(˚C

)

- 1 0 - 8 - 6 - 4 - 2 0 2 4 6 8 1 0

Power source : 50Hz, 220V

PIPE SIZEGAS LIQUID3/8" 1/4" 10 m 5 m

STANDARD PERMISSIBLE LENGTH

PERMISSIBLE LEVEL DIFFERENCE

Page 25: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

25

DISASSEMBLING PROCEDURE

FOR INDOOR UNIT MODEL AY-A079E/AY-A099E

CAUTION: DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY SERVICING

1. Remove the 2 screw covers in the front panel. 4. Close the open panel softly, and then press " B " and" C " of it securely.Remove the front panel ass'y as to lift up.

3. Pull the open panel at " A " toward you.Remove a fixed screw.

2. Removr 2 fixed screws.

5. Loose a cord clamp screw and take it out.

6. Loose 3 screws on the terminal board and take outthe unit-to-unit cord from it.

A A

BBC

Page 26: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

26

7.Take the thermistor holder from evaporator. 11.Loosen 4 screws fixing control box and take out controlass'y.

8.Take out the thermistor from evaporator.

9.Disconnect fan motor connectors and others.

10.Loose 1 screw for a pipe cover and take it out.Loose the earth screw.

12.Loose a screw fixing drain pan ass'y.(Right side)

13.Loose 2 screws fixing drain pan ass'y.(Left side)

14.Loose a screw fixing drain hose.

Page 27: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

27

19.Loosen 2 screws fixing evaporator.15.When assembling make sure that O-ring is fitted tothe drain hose.

16.Take out the drain pan ass'y.

17.Loose a screw fixing cross flow fan to motor.

20.Take out the fan bearing ass'y.

21.Take out the cross flow fan while slightly lifting theevaporator.

18.Slide the cross fan leftward to depart from the motorshaft and take out fan motor.

O-ring

O-ringDrain hose

(Section)

Page 28: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

28

FOR OUTDOOR UNIT MODEL AE-A079E AND AE-A099E

CAUTION: DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY SERVICING

1 Remove the three (3) screws holding the right sideplate and take it out.

2 Remove the three (3) screws holding the left sideplate and take it out.

3 Remove the another screws holding the cabinet andtake it out..

NOTE: Number as shown in followingfigure is the moval order.

Fig. D-1

Left side plate

Condenser

Right side plateCabinet

Fan motor

Propeller fan

Compressor

Fan guard

2

1

Page 29: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

29

REF. NO. PART NO. DESCRIPTION Q'TY CODE

REPLACEMENT PARTS LIST [AY-A079E/AY-A099E]

CABINET AND UNIT PARTS1- 1 CMOT-A273JBK0 Fan motor sub assembly 1 BN1- 2 NFANCA042JBE0 Cross flow fan 1 BC1- 3 CSRA-A444JBK0 Drain pan assembly 1 BK1- 4 MJNTPA040JBFF Louver link 3 AC1- 5 MLOV-A135JBFF Horizontal adjustment louver A (Vertical louver A) 9 AC1- 6 MLOV-A136JBFF Horizontal adjustment louver B (Vertical louver B) 3 AC1- 7 MLOV-A133JBFE Vertical adjustment louver A (Horizontal louver A) 1 AK1- 8 MLOV-A134JBFE Vertical adjustment louver B (Horizontal louver B) 1 AK1- 9 PPACGA002JBE0 O ring 1 AA1-10 RMOT-A050JBE0 Louver motor 1 AY1-11 PGUMMA071JBE0 Motor cushion 1 AN1-12 LHLD-A197JBFP Louver holder 4 AC1-13 PGUMMA086JBE0 Motor cushion 1 AG1-14 PCOV-A190JBE0 Drain cover 1 AE1-15 CHLD-A053JBK0 Bearing assembly 1 AD1-16 LHLD-A187JBFA Tube holder 1 AD1-17 PSHE-A099JBE0 Evaporator sheet 1 AH1-18 LSPR-A006JBE0 Sheet spring for fixing evaporator seat 2 AB1-19 DCHS-A255JBK0 Cabinet assembly 1 AZ1-20 DWAK-A779JBK0 Panel assembly 1 AX1-21 PFILMA077JBEB Air filter 2 AN1-22 HDEC-B020JBEA Display cover 1 AL1-23 HBDG-A059JBEA Badge 1 AF1-24 LHLD-A209JBFA Front panel hinge R 1 AF1-25 MARMPA012JBFA Open panel hinge L 1 AD1-26 MARMPA013JBFA Open panel hinge R 1 AD1-27 LHLD-A208JBFA Front panel hinge L 1 AD1-28 PBOX-A120JBK0 Louver gear assembly 1 AZ1-29 NBRG-A026JBFA Louver bushing 2 AB1-30 PSHE-A098JBE0 Evaporator seal 1 AC1-31 TLABPA175JBR0 Louver seal 1 AB1-32 TSPC-C981JBRA Name label [AY-A079E] 1 AD1-32 TSPC-C955JBRA Name label [AY-A099E] 1 AD1-33 PGUMSA046JBE0 Damper rubber 1 AD1-34 CPNL-A084JBK0 Open panel assembly 1 AV1-35 PFPFPB074JBE0 Thermistor insulation 1 AB1-36 PHOS-A015JBE0 Drain hose 1 AL1-37 LHLD-A204JBF0 Motor holder 1 AE1-38 PSEL-B417JBE0 Aluminum tape 1 AC1-39 PSEL-B418JBE0 Aluminum tape 1 AD1-40 PSEL-B494JBE0 Aluminum tape 1 AD1-41 PSEL-B492JBE0 Aluminum tape 1 AC

CONTROL BOX PARTS2- 1 FSGY-A141JBK0 Display board unit 1 AS2- 2 FPWBFA013JBK0 Switch board unit 1 AM2- 3 QTAN-A087JBE0 Terminal board (5P) 1 AS2- 4 QTAN-A088JBE0 Terminal board (3P) 1 AP2- 5 DPWBFA151JBK0 Control board unit [AY-A079E] 1 BQ2- 5 DPWBFA149JBK0 Control board unit [AY-A099E] 1 BR2- 6 QFS-AA050JBE0 Fuse 250V 2.5A 1 AD2- 7 QACC-A194JBE0 Power supply cord 1 AU2- 8 RTRN-A182JBE0 Transformer 1 AY2- 9 RC-HZA195JBE0 Fan motor capacitor 1 AL2-10 RTHM-A296JBE0 Thermistor 1 AN2-11 LHLD-A190JBF0 Thermistor holder 1 AG2-12 PBOX-A149JBF0 Control box 1 AN2-13 HPNLCA497JBF0 Control box cover 1 AF2-14 HPNLCA616JBE0 Control panel 1 AE2-15 LHLD-A266JBF0 Cord holder 1 AE2-16 LHLD-A265JBF0 Cord clamp 1 AC2-17 TLABCB254JBR0 Wiring diagram 1 AC2-18 PSHE-A076JBE0 Protection cover 1 AE2-19 PGUMMA095JBE0 Wire cushion 1 AA2-20 PCOV-A191JBE0 LED holder 1 AD2-21 RH-IXA519JBE0 Microcomputer (IC1) 1 AX2-22 RH-IZA149JBE0 Integrated circuit (IC2) 1 AE2-23 RIC--A022BDE0 Integrated circuit (IC3) 1 AE2-24 RIC--A025BDE0 Integrated circuit (IC4) 1 AE2-25 RH-IZA140JBE0 Integrated circuit (IC5) 1 AE2-26 RH-IZA337DRE0 EEPROM(IC6) 1 AK2-27 VHRS201D01/-6 Solid state relay(SSR) 1 AK2-28 RRLYJA067JBE0 Relay (RY) 1 AP2-29 RFIL-A042JBE0 Coil (L) 1 AM

Page 30: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

30

REF. NO. PART NO. DESCRIPTION Q'TY CODE

HOW TO ORDER REPLACEMENT PARTS

To have your order filled prompty and correctly, please furnish the following information.

1. MODEL NUMBER 2. REF. NO.3. PART NO. 4. DESCRIPTION

2-30 RH-VZA025JBE0 Varistor (NR) 1 AD2-31 RC-QZA096JBE0 Capacitor (C1) 1 AE2-32 RTRN-A181JBE0 Current transformer(CT) 1 AN2-33 RH-VZA020JBE0 Varistor (CNR1, CNR2) 2 AE2-34 RRLYJA059JBE0 Relay (RY2, RY3) 2 AN

CYCLE PARTS3- 1 CPIPCA612JBK0 Pipe assembly 1 AZ3- 2 PEVA-A244JBE0 Evaporator 1 BS

ACCESSORY PARTS4- 1 LX-NZ0247JBE0 Wall plug, fixing Mounting plate 7 AB4- 2 XTTSD45P30000 Screw for Wall plug 6 AA4- 3 CRMC-A489JBE0 Wireless remote controller 1 BG4- 4 LX-BZA106JBE0 Special screw 1 AD4- 5 TINS-A563JBR0 Installation manual 1 AD4- 6 TINSEA220JBR0 Operation manual 1 AP4- 7 PPLTNA022JBP0 Mounting plate 1 AL4- 8 TINS-A564JBR0 Installation manual 1 AD4- 9 FCOV-A013JBFS Screw cover 2 AC4-10 LPFT-A022JBF0 Drain joint 1 AD

SCREWS AND RING6- 1 LX-BZA075JBE0 Special screw 1 AA6- 2 XREUW50-06000 Ring 2 AA

Page 31: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

31

A

B

C

D

E

F

G

H

A

1 2 3 4 5 6

1 2 3 4 5 6

B

C

D

E

F

G

H

1-30

1-173-2

3-1

4-7

1-16

1-191-18

2-10

1-2

1-15

2-14

2-15

2-3

2-132-2

2-18

2-1

2-7

2-122-9

4-24-1

4-64-4

4-3

4-9

2-20

1-3

1-101-81-121-7

1-361-9

1-6

2-10

1-4

1-17

2-11 6-1

1-14

1-37

1-51-31

1-29

1-33

1-211-32

2-17

6-2

1-13

1-111-25

1-27

1-20

1-11-28

1-26

1-24

1-22

1-34

1-23

2-4

2-8

2-5

2-16

1-41

2-191-35

4-5

4-8

1-40

1-39

1-38

4-10

INDOOR UNIT FOR AY-A079E AND AY-A099E

Page 32: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

32

REPLACEMENT PARTS LIST [AE-A079E/AE-A099E]

REF. NO. PART NO. DESCRIPTION Q'TY CODE

CABINET AND UNIT PARTS1- 1 PSEL-A345JBE0 Cabinet seal 1 AK1- 2 CMOTLA592JBE0 Fan motor 1 BP1- 3 NFANPA020JBEA Propeller fan 1 AW1- 4 PANGKA018JBP0 Fan motor angle 1 AP1- 5 PSKR-0106JBP0 Bulkhead 1 AM1- 6 GPLTPA014JBFA Left side cover 1 AR1- 7 GFTA-A387JBF0 Terminal cover 1 AH1- 8 GBOX-A004JBFA Right side cover 1 AS1- 9 GCAB-A105JBTA Cabinet 1 BA1-10 GGADFA030JBEA Fan guard 1 AY1-11 PSEL-A346JBE0 Bulkhead seal 1 AK1-12 PSPF-A430JBE0 Compressor cover [AE-A079E] 1 AV1-12 PSPF-A692JBE0 Compressor cover [AE-A099E] 1 AY1-13 PGUMSA202JBE0 Damper rubber [AE-A079E only] 1 AE1-14 TSPC-C958JBR0 Name label [AE-A079E] 1 AD1-14 TSPC-C957JBR0 Name label [AE-A099E] 1 AE1-15 TLABBA029JBRA SHARP badge 1 AD1-16 CCHS-A464JBTA Base pan assembly [AE-A079E] 1 BF1-16 CCHS-A636JBTA Base pan assembly [AE-A099E] 1 BF1-17 PSPF-A277JBE0 Angle seal 1 AK1-18 PSEL-A347JBE0 Angle seal 2 AK1-19 PSEL-A344JBE0 Condenser seal 1 AK1-20 LBSHCA022JBF0 Bushing 1 AE

CONTROL BOX PARTS2- 1 RHOG-A107JBE0 Protector [AE-A079E] 1 AX2- 2 TLABPA182JBE0 Badge 1 AC2- 3 CW-VZA208JBK0 C wire sub assembly [AE-A079E] 1 AR2- 3 QW-VZD438JBE0 C wire sub assembly [AE-A099E] 1 AQ2- 4 RC-HZA316JBE0 Running capacitor 1 AY2- 5 RC-HZA071JBE0 Fan motor capacitor 1 AH2- 6 QTAN-A145JBE0 Terminal board 1 AQ2- 7 LHLD-0261JBM0 Cord holder 1 AB2- 8 PCOV-A455JBP0 Capacitor cover 1 AF2- 9 PCOV-A471JBP0 Terminal cover 1 AR2-10 TLABCA662JBR0 Wiring diagram [AE-A079E] 1 AB2-10 TLABCB152JBR0 Wiring diagram [AE-A099E] 1 AC

CYCLE PARTS3- 1 PCMPRA177JBE0 Compressor [AE-A079E] 1 CM3- 1 PCMPRA289JBE0 Compressor [AE-A099E] 1 CG3- 2 PCON-A263JBP0 Condenser [AE-A079E] 1 BY3- 2 PCON-A407JBP0 Condenser [AE-A099E] 1 BY3- 3 DVLV-A189JBK0 2 Way valve assembly 1 BA3- 4 PSEN-A004JBK0 Flare nut assembly 1/4" 1 AE3- 5 LX-NZA033JBE0 Valve cap 2 AF3- 6 PSEL-A006JBE0 Terminal gasket [AE-A079E] 1 AC3- 6 PSEL-B172JBE0 Terminal gasket [AE-A099E] 1 AD3- 7 DVLV-A212JBK0 3 way valve unit 1 BB3- 8 PSEN-A005JBK0 Flare nut assembly 3/8" 1 AG3- 9 LX-NZA034JBE0 Service cap 1 AD3-10 CCIL-A064JBK0 Reverse valve coil assembly 1 AW3-11 PCPY-A281JBE0 Capillary tube [AE-A079E] 1 AP3-11 PCPY-A665JB10 Capillary tube [AE-A099E] 1 AH3-12 PCPY-A282JBE0 Capillary tube [AE-A079E] 1 AN3-12 PCPY-A666JB10 Capillary tube [AE-A099E] 1 AG3-13 PSRN-A040JBE0 Strainer 1 AN3-14 GLEG-A073JBE0 Compressor cushion [AE-A079E] 3 AD3-15 PVLVXA009JBE0 Reverse valve 1 BE3-16 LX-NZA028JBE0 Special nut 3 AB3-17 PGUMS0147JBE0 Damper rubber 1 AE3-18 PCOV-A002JBE0 Terminal cover [AE-A079E] 1 AE3-18 PCOV-A378JBE0 Terminal cover [AE-A099E] 1 AH3-19 PVLVC0353JBE0 Check valve [AE-A079E] 1 AK3-19 PPIPCB449JBE0 Check valve [AE-A099E] 1 AM3-20 PGUMSA033JBE0 Damper rubber [AE-A099E] 1 AH3-21 PSEL-B722JBE0 Rubber washer [AE-A099E] 1 AE3-22 PGUMS0227JBE0 Damper rubber [AE-A079E] 1 AF3-22 PGUMSA234JBE0 Damper rubber [AE-A099E] 1 AK3-23 LX-NZA002JBE0 Special nut [AE-A079E] 1 AA3-23 LX-NZA051JBE0 Special nut [AE-A099E] 1 AH3-24 LX-NZA081JBE0 Bonnet 2 AG

Page 33: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

33

SCREWS, NUT AND WASHER6- 1 LX-WZA019JBE0 Special washer 1 AB6- 2 LX-BZA078JBE0 Special screw 3 AB6- 3 LX-BZA075JBE0 Special screw 1 AA6- 4 LX-BZA127JBE0 Special screw 1 AC6- 5 LX-NZA030JBE0 Special nut 1 AB6- 6 LX-CZA038JBE0 Special screw 2 AB6- 7 LX-BZA076JBE0 Special screw 4 AA6- 8 XTTUW40P16000 Tapping screw 2 AB

REF. NO. PART NO. DESCRIPTION Q'TY CODE

HOW TO ORDER REPLACEMENT PARTS

1. MODEL NUMBER 2. REF. NO.3. PART NO. 4. DESCRIPTION

Page 34: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

34

A

B

C

D

E

F

G

H

A

1 2 3 4 5 6

1 2 3 4 5 6

B

C

D

E

F

G

H

1-6

3-2

3-233-21

3-183-6

2-1

2-3

1-16

1-18

1-4

1-181-3

6-5

6-1

1-2

1-9

1-1

1-8

2-8

1-7

2-4

2-52-9

2-6

2-7

1-151-10

1-11

1-20

1-5

1-17

3-14

3-163-20

1-12

3-15

3-173-11, 3-12

3-22

3-10

3-19

1-13

6-4

2-10

1-14

2-2

3-8

3-24

3-24

3-4

3-36-2

6-26-2 6-2

3-5

3-53-9

3-7

OUTDOOR UNIT FOR AE-A079E AND AE-A099E

Page 35: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

35

Page 36: AY/AE-A079E/A099E Service-Manual GB

AY/AE-A079EAY/AE-A099E

36 '99 SHARP CORP. (2U0.70E) Printed in Netherlands


Recommended