+ All Categories
Home > Documents > B-EX700-RFID-H3-QM-R Installation Manual 1. -...

B-EX700-RFID-H3-QM-R Installation Manual 1. -...

Date post: 28-Jul-2021
Category:
Upload: others
View: 5 times
Download: 0 times
Share this document with a friend
8
1/15 B-EX700-RFID-H3-QM-R Installation Manual Thank you for purchasing TOSHIBA TEC HF RFID kit, B-EX700-RFID-H3-QM-R. The B-EX700-RFID-H3-QM-R is exclusively for the B-EX4T1-GS12/TS12-QM-R. This unit must come together with B-EX904-R-QM-R Ribbon Saving Module during installation. This RFID kit complies with radio laws of all applicable countries. As this product is a wireless communication device, please be sure to read the following precautions carefully. WARNING! 1. Do not use a printer embedded with this product near medical equipment. Radio wave emitted from this product may affect the operation of medical equipment, such as an implanted cardiac pacemaker and implantable cardioverter-defibrillator. If a use of this product should be likely to have affected medical equipment, immediately turn off the product and contact your TOSHIBA TEC sales agent. Keep a printer embedded with this product at least 23cm away from a person with an implanted cardiac pacemaker or implantable cardioverter-defibrillator. 2. Do not export a printer embedded with this product to the countries or areas where a use of this product is not allowed, without permission. Doing so is against the law, and you may be punished. When exporting this product, check the laws and regulations of a destination country and take necessary procedures. 3. Follow all manual instructions. Failure to do so could create safety hazards such as fire or electrocution. Manual instructions must be followed when installing option kits or adding cables to avoid system failures and to insure proper performance and operation. Failure to follow manual instructions or any unauthorized modifications, substitution or change to this product will void the limited product warranty. 4. Turn the power OFF and disconnect the power cord before installing the RFID module. 5. Be careful not to pinch your fingers or hands with the covers. 6. The print head and stepping motor becomes very hot immediately after printing. Do not touch the print head, stepping motor and around it right after printing, or you may get burned. 7. When opening the top cover, it must be fully opened. Failure to do this may cause the top cover to close under its own weight, resulting in an injury. 2/15 1. APPLICABLE MODEL (1) This optional device is intended for the following models: B-EX4T1-GS/TS12-QM-R Be careful not to install this product in any other models than above. (2) The countries where the use of this device is allowed are as follows: Module Name Frequency Band Applicable Countries TRW-HFM-01 HF 13.56 MHz Korea 2. PACKING LIST All the following parts are supplied with the kit. Make sure you have all items shown below. If any part is missing, please contact your TOSHIBA TEC sales agent. Antenna Unit (1 pc.) RFID R/W Module (1 pc.) Ribbon Guide (1 pc.) Interface Cable (1 pc.) Cord Bush (1 pc.) Antenna Cable (1 pc.) Double-Sems Screw SMW-3x6 (1 pc.) Tapping Screw PT-3x6 (5 pcs.) R/W Module Attachment Plate (2 pcs.) Earth Plate (1 pc.) Installation Manual (1 copy)
Transcript
Page 1: B-EX700-RFID-H3-QM-R Installation Manual 1. - Toshibabusiness.toshiba.com/downloads/KB/f1Ulds/15116/B-EX4T1... · 2017. 3. 24. · models: B-EX4T1-GS/TS12-QM-R Be careful not to install

1/15

B-EX700-RFID-H3-QM-R Installation Manual

Thank you for purchasing TOSHIBA TEC HF RFID kit, B-EX700-RFID-H3-QM-R. The B-EX700-RFID-H3-QM-R is exclusively for the B-EX4T1-GS12/TS12-QM-R. This unit must come together with B-EX904-R-QM-R Ribbon Saving Module during installation. This RFID kit complies with radio laws of all applicable countries. As this product is a wireless communication device, please be sure to read the following precautions carefully.

WARNING! 1. Do not use a printer embedded with this product near medical equipment. Radio wave emitted

from this product may affect the operation of medical equipment, such as an implanted cardiac pacemaker and implantable cardioverter-defibrillator. If a use of this product should be likely to have affected medical equipment, immediately turn off the product and contact your TOSHIBA TEC sales agent. Keep a printer embedded with this product at least 23cm away from a person with an implanted cardiac pacemaker or implantable cardioverter-defibrillator.

2. Do not export a printer embedded with this product to the countries or areas where a use of this product is not allowed, without permission. Doing so is against the law, and you may be punished. When exporting this product, check the laws and regulations of a destination country and take necessary procedures.

3. Follow all manual instructions. Failure to do so could create safety hazards such as fire or electrocution. Manual instructions must be followed when installing option kits or adding cables to avoid

system failures and to insure proper performance and operation. Failure to follow manual instructions or any unauthorized modifications, substitution or

change to this product will void the limited product warranty. 4. Turn the power OFF and disconnect the power cord before installing the RFID module. 5. Be careful not to pinch your fingers or hands with the covers. 6. The print head and stepping motor becomes very hot immediately after printing. Do not touch

the print head, stepping motor and around it right after printing, or you may get burned. 7. When opening the top cover, it must be fully opened. Failure to do this may cause the top cover

to close under its own weight, resulting in an injury.

2/15

1. APPLICABLE MODEL (1) This optional device is intended for the following

models: B-EX4T1-GS/TS12-QM-R Be careful not to install this product in any other models than above.

(2) The countries where the use of this device is allowed are as follows:

Module Name Frequency Band Applicable Countries

TRW-HFM-01 HF 13.56 MHz Korea

2. PACKING LIST All the following parts are supplied with the kit. Make sure you have all items shown below. If any part is missing, please contact your TOSHIBA TEC sales agent.

Antenna Unit (1 pc.)

RFID R/W Module (1 pc.)

Ribbon Guide (1 pc.)

Interface Cable (1 pc.)

Cord Bush (1 pc.)

Antenna Cable (1 pc.)

Double-Sems Screw SMW-3x6 (1 pc.)

Tapping Screw PT-3x6 (5 pcs.)

R/W Module Attachment Plate (2 pcs.)

Earth Plate (1 pc.)

Installation Manual (1 copy)

Page 2: B-EX700-RFID-H3-QM-R Installation Manual 1. - Toshibabusiness.toshiba.com/downloads/KB/f1Ulds/15116/B-EX4T1... · 2017. 3. 24. · models: B-EX4T1-GS/TS12-QM-R Be careful not to install

3/15

Top Cover

3. INSTALLATION PROCEDURE 3.1 Removing the Covers

1. Turn the printer power off and disconnect the Power Cord. 2. Remove the three B-4x5 screws from the Side Panel (L). 3. Slide the Side Panel (L) backward, and raise it to remove from the printer.

B-4x5 Screw

Side Panel (L)

B-4x5 Screw

4. Fully open the Top Cover.

4/15

Head Lever

5. Release the tab on the right end by pushing it, then remove the Front Panel.

3.2 Attaching the Ribbon Guide 1. Turn the Head Lever to the FREE position and gently open the Ribbon Shaft Holder

Plate.

Front Panel

Tab

Ribbon Shaft Holder Plate

Page 3: B-EX700-RFID-H3-QM-R Installation Manual 1. - Toshibabusiness.toshiba.com/downloads/KB/f1Ulds/15116/B-EX4T1... · 2017. 3. 24. · models: B-EX4T1-GS/TS12-QM-R Be careful not to install

5/15

2. Open the Print Head Block.

Print Head Block

3. Remove the E-Ring from the left-hand Ribbon Guide Shaft, as viewed from the Head Lever side, and take off the Ribbon Guide Shaft.

Head Lever

When viewed from the lower front side

E-Ring

4. Disconnect the Ribbon End Sensor Harness from the Ribbon End Sensor.

NOTE: Keep the removed Ribbon Guide Shaft for future use.

Ribbon Guide Shaft

Ribbon End Sensor

Sensor Harness

6/15

5. Separate the Sensor PCB from the Sensor Frame.

6. Fit the Sensor PCB into the Ribbon Guide.

7. Connect the Ribbon End Sensor Harness to the Sensor PCB.

Sensor PCB

Ribbon End Sensor Harness Ribbon Guide

Sensor PCB

Sensor Frame

Ribbon Guide

Sensor PCB

Page 4: B-EX700-RFID-H3-QM-R Installation Manual 1. - Toshibabusiness.toshiba.com/downloads/KB/f1Ulds/15116/B-EX4T1... · 2017. 3. 24. · models: B-EX4T1-GS/TS12-QM-R Be careful not to install

7/15

② Fit into the Ribbon Guide Shaft.

8. Install the Ribbon Guide in the position from which the Ribbon Guide Shaft has been removed. ① Insert the shaft of the Ribbon Guide into the hole at the front side and then its other

side into the hole at the opposite side.

② Push up the unsecured side of the Ribbon Guide and then fit the hook into the Ribbon Guide Shaft at the right-hand side.

3.3 Attaching the Antenna Unit 1. Connect the Antenna Cable to the Antenna.

Antenna attachment position

Antenna

Antenna Unit

Hook Ribbon Guide Shaft

Antenna Cable

① Insert the front side first.

Ribbon Guide

8/15

Tip: Align the four corners of the Antenna Unit to the notches indicated by the circles.

Platen Holder

2. As shown in the figure below, hold the Antenna Unit so that the Antenna comes to the lower side and the antenna attachment position comes to the right-hand side. Then fit the Antenna Unit into the bottom surface of the Platen Holder.

Antenna Cable Antenna Unit

3. Secure the lower side of the Earth Plate to the Platen Holder Frame together by using its fixing screw.

Platen Holder Frame

4. Secure the upper side of the Earth Plate to Antenna Unit with the screw (SMW-3x6).

Earth Plate

Screw (SMW-3x6)

Page 5: B-EX700-RFID-H3-QM-R Installation Manual 1. - Toshibabusiness.toshiba.com/downloads/KB/f1Ulds/15116/B-EX4T1... · 2017. 3. 24. · models: B-EX4T1-GS/TS12-QM-R Be careful not to install

9/15

3.4 Attaching the RFID R/W Module 1. Fit the Cord Bush into the round hole on the Main Frame.

(When viewed from the front side)

2. Pass the Antenna Cable through the Cord Bush.

Antenna Cable

3. Pull out the Antenna Cable from the opposite side and pass it through the inside of

the Cable Guard.

Cable Guard

Antenna Cable

Main Frame

Cord Bush

Cord Bush

10/15

Interface CableScrew (PT-3x6)

4. Secure two R/W Module Attachment Plates with one screw (PT-3x6) respectively.

5. Connect the Interface Cable to the RFID R/W Module and install it in the attachment plate

with three screws (PT-3x6).

Screw (PT-3x6)

R/W Module Attachment Plate

RFID R/W Module

Screw (PT-3x6)

Screw (PT-3x6) R/W Module Attachment Plate

Page 6: B-EX700-RFID-H3-QM-R Installation Manual 1. - Toshibabusiness.toshiba.com/downloads/KB/f1Ulds/15116/B-EX4T1... · 2017. 3. 24. · models: B-EX4T1-GS/TS12-QM-R Be careful not to install

11/15

J1 Connector Interface Cable

6. Insert the Antenna Cable into the connector of the RFID R/W Module.

7. Insert the other side of the connector of the Interface Cable into the J1 Connector of

the Main PCB.

Main PCB

RFID R/W Module

8. By paying attention so as not to catch the cables, attach the Front Panel and the Side Cover (L) in the reverse procedure of the removal.

Side Cover (L)

Front Panel

9. The installation of the RFID kit in the printer is now completed. Perform various settings related to the RFID in the System Mode of the printer.

Antenna Cable

RFID R/W Module

12/15

4. RFID MODULE SETTINGS After installing the RFID Module in the printer, set various settings related to the RFID in the System Mode of the printer.

■ How to enter the System Mode

SYSTEM MODE

Press [ENTER].

■ Contents of the RFID Menu Menu Sub menu Parameter RFID TEST ID READ

MODULE MODULE TYPE COUNTRYTAGRF CHANNEL

RETRY ADJ RETRY POSITIONISSUE RETRY LABELSREAD RETRYWRITE RETRY

UHF SETTING POWER LEVELQ VALUEAGC THRESHOLDWRITE AGC THRESHOLDWRITE RETRY MIN AGC

OTHER TAG CHECKMULTI WRITECARRIER SENSE

These items cannot be set in this kit. ■ Key functions in the system mode

Key Function [MODE] Returns to the mode menu screen. [CANCEL] or [FEED]+[RESTART]

Returns to the upper hierarchy.

[ENTER] or [PAUSE] Displays a next screen. Saves the setting and returns to the upper hierarchy.

[UP] or [RESTART] Moves the cursor upward. Increases a value.

[DOWN] or [FEED] Moves the cursor downward. Decreases a value.

[LEFT] Moves the cursor to the left. [RIGHT] Moves the cursor to the right.

Turn on the printer while holding down [FEED] & [PAUSE] or [MODE].

Power OFF

<1>DIAG. <2>PARAMETER SET <3>ADJUST SET <4>TEST PRINT

Press [DOWN] until “<10>RFID”

is highlighted.

<7>INTERFACE <8>BASIC <9>FOR FACTORY <10>RFID

SYSTEM MODE

Page 7: B-EX700-RFID-H3-QM-R Installation Manual 1. - Toshibabusiness.toshiba.com/downloads/KB/f1Ulds/15116/B-EX4T1... · 2017. 3. 24. · models: B-EX4T1-GS/TS12-QM-R Be careful not to install

13/15

4.1 Test

(1) ID READ The printer enters the read test mode to read the data of the RFID tag, and a read test is performed each time the [ENTER] key is pressed. When the data of a tag can be read, they are displayed on the LCD.

(Example)

▪ Only the tags selected for the RFID tag type can be read. If the type of the tag to be read does not match the one selected in the RFID tag type, an error will occur. Therefore, the RFID tag type shall be selected before the read test is started.

▪ When the read test has failed, the following message is displayed on the LCD:

Error message Description

MODULE TYPE ERROR RFID module type has been set to NONE or a communicationcannot be established.

COUNTRY CONFIG ERROR Country/Region code has not been set. READ ERROR Confirm Setting or Set other Tag

The type of the tag to be read and one selected by the RFIDtag type selection do not match.

NOT AVAILABLE Not supported. NO RESPONSE No response from the tag READ TIMEOUT Set a RF-Tag on Ant. Timeout

UNKNOWN ERROR Other errors

▪ In the case of 32 digits or more data, only the first 32 digits are displayed. When the data are less than 32 digits, the vacant digits will be filled with spaces.

▪ If more than one tag is read at one time, especially when short-pitch tags are used, pressing the [UP] or [DOWN] key shows the other tags’ data.

4.2 Module (1) MODULE TYPE

NONE: No RFID module is installed. H1: B-EX700-RFID-H1-QM-R H2: B-EX700-RFID-H2-R, B-EX700-RFID-H3-QM-R U2: B-EX700-RFID-U2-US/EU-R, B-EX700-RFID-U4-US/EU-R, U4 module

preinstall model (B-EX4T1/EX4T2-GS18/TS18-CN-R)

Tip: This setting will become effective after the printer power is turned off and then back on.

(2) COUNTRY This is not available. Do not use this module.

ID READ TAG 1/1 00010203 04050607

The number of the tag is being read / The total number of tags d

The data of the read tag are displayed in hex.

14/15

(3) TAG None ISO15693

(4) CHANNEL This is not available. Do not use this module.

4.3 Retry

(1) ADJ RETRY POSITION

If writing data on a tag has failed, the printer feeds the RFID tag forward or backward for the specified length in order to retry the data write. When “0” is set for this parameter, this function and a retry are not performed. Only the value of –3mm or less or +3mm or more becomes effective. (Default value: 0 mm) * "-": Forward, "+": Backward

(2) ISSUE RETRY LABELS

(3) READ RETRY ● The number of times a tag read is retried

Set the maximum number of retries to issue an RFID tag. If printing does not succeed even after the maximum number of retires, the printer stops, resulting in an error. Moreover, when the issuing of an RFID tag has failed, the printer prints the error pattern ("VOID) on the label. (Default value: 3 times)

Set the maximum number of retries to read an RFID tag. The printer retries to read the data in an RFID tag for up to the specified number of times. If the timeout period expired before the maximum number of retries have been done, the printer stops the retries at this time. Whenever the printer writes data onto an RFID tag, the tag is read first. The maximum number of retries set by this parameter becomes also effective in this pre-read. (Default value: 5 times)

99mm

98mm

-98mm

-99mm

255

254

1

0

255

254

1

0

Page 8: B-EX700-RFID-H3-QM-R Installation Manual 1. - Toshibabusiness.toshiba.com/downloads/KB/f1Ulds/15116/B-EX4T1... · 2017. 3. 24. · models: B-EX4T1-GS/TS12-QM-R Be careful not to install

15/15

● Read retry timeout

(4) WRITE RETRY ●The number of times a tag write is retried

Set the timeout period during which RFID tag read retries are allowed, with the [UP] or [DOWN] key. If the printer has retried for the maximum number of times within the RFID read retry timeout, the printer stops the retries at this time. Whenever the printer writes data onto an RFID tag, the tag is read first. The read retry timeout set by this parameter also becomes effective in this pre-read. (Default value: 4.0 seconds)

Set the maximum number of retries to write data onto an RFID tag. The printer retries to write data onto an RFID tag for up to the specified number of times. If the timeout period expired before the maximum number of retries have been done, the printer stops the retries at this time. (Default value: 5 times)

● Write retry timeout

Set the timeout period during which RFID tag write retries are allowed, with the [UP] or [DOWN] key. If the printer has retried for the maximum number of times within the RFID write retry timeout, the printer stops the retries at this time. (Default value: 2.0 seconds)

PRINTED IN JAPAN EO2-38118

9.9 sec.

9.8 sec.

0.1 sec.

0.0 sec.

255

254

1

0

9.9 sec.

9.8 sec.

0.1 sec.

0.0 sec.

© 2017 TOSHIBA TEC CORPORATION All Rights Reserved 1-11-1, Osaki, Shinagawa-ku, Tokyo 141-8562, JAPAN