BLDG-0048 Revised 04-02-2020 Page 1 of 1 B RESIDENTIAL HVAC REQUIREMENTS COMMUNITY DEVELOPMENT DEPARTMENT • 345 N EL DORADO STREET • STOCKTON, CA 95202 • (209) 937-8561 www.stocktonca.gov/buildinginspection PERMIT REQUIREMENTS: A building permit is required for the following residential HVAC projects: o New HVAC installation o HVAC Changeout o Replacement of furnace, coil, FAU, or condenser o Relocation of an existing HVAC unit o Adding or replacing more than 40 feet of ducting Permits are issued to either the property owner with a completed Owner/Builder form or to California licensed C-20 contractor with a current City of Stockton Business License. Permits can be obtained at the Community Development Department Permit Center. o Located at 345 N. El Dorado St, Stockton, CA 95202 o Office hours are from 8:00 a.m. to 4:30 p.m. Monday through Friday, closed alternate Fridays. Residential HVAC permits may also be submitted remotely by sending a complete digital package to [email protected] SUBMITTAL CHECKLIST: A. Completed Building Permit Application B. Energy Compliance Forms See below C. Gas Pipe Sizing Calculations (if applicable) D. Completed Owner/Builder Form (if applicable) E. Authorization Letter from the licensed contractor for the individual picking up the permit (if applicable) F. Plans Required for new units installed on a roof or in an attic ENERGY CODE COMPLIANCE: Refer to the attached document from Energy Code Ace summarizing the minimum required equipment efficiencies. Refer to the attached document from Energy Code Ace summarizing the requirements for HVAC alterations. Altered or new/replacement cooling systems trigger the installation of a setback thermostat. Newly installed or replaced ducts must have a minimum insulation value of R-6. Duct sealing and testing (HERS measure) is required for both altered and new/replacement duct systems. FORMS: CF1R-ALT-02-E o Required at time of permit application. Must be registered with a HERS provider prior to permit application. CF2R-MCH-01 & CF3R MCH Forms o Completed and signed by the installing contractor and made available for final inspection by the Building Department. Must be registered with a HERS provider.
Transcript

BLDG-0048 Revised 04-02-2020 Page 1 of 1

B RESIDENTIAL HVAC REQUIREMENTS

COMMUNITY DEVELOPMENT DEPARTMENT • 345 N EL DORADO STREET • STOCKTON, CA 95202 • (209) 937-8561

www.stocktonca.gov/buildinginspection

PERMIT REQUIREMENTS:

• A building permit is required for the following residential HVAC projects:

o New HVAC installation

o HVAC Changeout

o Replacement of furnace, coil, FAU, or condenser

o Relocation of an existing HVAC unit

o Adding or replacing more than 40 feet of ducting

• Permits are issued to either the property owner with a completed Owner/Builder form or to California licensed C-20 contractor with a current City of Stockton Business License.

• Permits can be obtained at the Community Development Department Permit Center.

o Located at 345 N. El Dorado St, Stockton, CA 95202

o Office hours are from 8:00 a.m. to 4:30 p.m. Monday through Friday, closed alternate Fridays.

• Residential HVAC permits may also be submitted remotely by sending a complete digital package to [email protected]

SUBMITTAL CHECKLIST:

A. Completed Building Permit Application

B. Energy Compliance Forms – See below

C. Gas Pipe Sizing Calculations (if applicable)

D. Completed Owner/Builder Form (if applicable)

E. Authorization Letter from the licensed contractor for the individual picking up the permit (if applicable)

F. Plans – Required for new units installed on a roof or in an attic

ENERGY CODE COMPLIANCE:

• Refer to the attached document from Energy Code Ace summarizing the minimum required equipment efficiencies. • Refer to the attached document from Energy Code Ace summarizing the requirements for HVAC alterations. • Altered or new/replacement cooling systems trigger the installation of a setback thermostat. • Newly installed or replaced ducts must have a minimum insulation value of R-6. • Duct sealing and testing (HERS measure) is required for both altered and new/replacement duct systems.

FORMS:

➢ CF1R-ALT-02-E o Required at time of permit application. Must be registered with a HERS provider prior to permit

application. ➢ CF2R-MCH-01 & CF3R MCH Forms

o Completed and signed by the installing contractor and made available for final inspection by the Building Department. Must be registered with a HERS provider.

Gas- and Oil-Fired Central Furnaces – Minimum Heating Efficiencies

ApplianceRated Input (Btuh)

Minimum Efficiency (%)

AFUEThermal

Efficiency

Weatherized gas central furnaces with single phase electrical supply < 225,000 81% —

Non-weatherized gas and oil central furnaces with single phase electrical supply < 225,000 80% —

Weatherized oil central furnaces with single phase electrical supply < 225,000 78% —

Non-weatherized oil central furnaces with single phase electrical supply < 225,000 83% —

Gas central furnaces ≥ 225,000 — 80%

Oil central furnaces ≥ 225,000 — 81%

Table 4-1 of 2019 Residential Compliance Manual (based on the California Appliance Efficiency Regulations Title 20, Tables E-5 and E-6)

Heat Pump – Minimum Heating EfficienciesSingle-phase air source heat pumps

Configuration Size (Btuh) Minimum Heating Efficiency

Packaged < 65,000 Cooling Capacity 8.0 HSPF

Split < 65,000 Cooling Capacity 8.2 HSPF

Space-constrained packaged < 65,000 Cooling Capacity 7.4 HSPF

Space-constrained split < 65,000 Cooling Capacity 7.4 HSPF

Small Duct High Velocity < 65,000 Cooling Capacity 7.2 HSPF

Note – HSPF: Heating Season Performance Factor

Adapted from Table 4-3 of 2019 Residential Compliance Manual (based on Title 20)

Title 24, Part 6

Climate Zone Quick Reference

2019 Title 24, Part 6 - Residential Heating & Cooling Equipment Minimum Efficiencies Page 1 of 2 2020-03-03

Energy CodeAceHelping you play your cards right

Residential Heating & Cooling Equipment

Minimum Efficiencies

2019 ENERGY CODE

(Smaller) Central Air Conditioners and Heat Pumps — Minimum Cooling Efficiencies

Appliance Type Size (Btuh)SEER

Effective 1/1/2015

EER Effective 1/1/2015

Central Air ConditionersSplit System

< 45,000 14.0 12.2≥ 45,000 and < 65,000 14.0 11.7

Single Package < 65,000 14.0 11.0

Central Air Source Heat PumpsSplit System < 65,000 14.0 NR

Single Package < 65,000 14.0 NR

Space Constrained Air ConditionerSplit System < 65,000 12.0 NR

Single Package < 65,000 12.0 NR

Space Constrained Heat PumpSplit System < 65,000 12.0 NR

Single Package < 65,000 12.0 NRSmall Duct, High Velocity Air Conditioner All < 65,000 12.0 NRSmall Duct, High Velocity Heat Pump All < 65,000 12.0 NR

Adapted from Table 4-6 from 2019 Residential Compliance Manual (based on Title 20 Table C-3 and Federal Appliance Standards)

Federally Regulated Residential Water Heaters — Minimum Domestic Hot Water (DHW) Efficiencies

Product ClassRated Storage

Volume/Input Rating (if applicable)

Draw Pattern Uniform Energy Factor (UEF) Minimum Requirement

Gas-fired Storage Water Heater (≥20 gal and ≤ 55 gal)

40 gallonMedium

0.580350 gallon 0.563340 gallon

High0.64

50 gallon 0.627

Gas-fired Storage Water Heater (>55 gal and ≤ 100 gal)

60 gallon

Medium

0.765770 gallon 0.761780 galllon 0.757790 gallon 0.7537100 gallon 0.749760 gallon

High

0.789270 gallon 0.786280 gallon 0.783290 gallon 0.7802100 gallon 0.7772

Instantaneous Gas-fired Water Heater <2 gal and > 50,000 Btuh Low/Medium/High 0.81Instantaneous Electric Water Heater <2 Gal Very Small/Low/Medium 0.91

Grid-enabled Water Heater80 gallon

High0.916

90 gallon 0.909100 gallon 0.902

Note – Vr= Rated Storage Volume – the water storage capacity of a water heater (in gallons).

From Table 5-4 of the 2019 Residential Compliance Manual (per U.S. Department of Energy)

This program is funded by California utility customers and administered by Pacific Gas and Electric Company (PG&E), San Diego Gas & Electric Company (SDG&E®), Southern California Edison Company (SCE), and Southern California Gas Company (SoCalGas®) under the auspices of the California Public Utilities Commission.© 2020 PG&E, SDG&E, SoCalGas and SCE. All rights reserved, except that this document may be used, copied, and distributed without modification. Neither PG&E, SoCalGas, SDG&E, nor SCE — nor any of their employees makes any warranty, express or implied; or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any data, information, method, product, policy or process disclosed in this document; or represents that its use will not infringe any privately-owned rights including, but not limited to patents, trademarks or copyrights. Images used in this document are intended for illustrative purposes only. Any reference or appearance herein to any specific commercial products, processes or services by trade name, trademark, manufacturer or otherwise does not constitute or imply its endorsement, recommendation or favoring.

EnergyCodeAce.com 2019 Title 24, Part 6 - Residential Heating & Cooling Equipment Minimum Efficiencies Page 2 of 2

2019 Title 24, Part 6 - Residential HVAC Alterations Page 1 of 4 2020-01-03

Residential

HVAC Alterations

Energy CodeAceHelping you play your cards right

AceResources

Title 24, Part 6

Fact Sheet2019 ENERGY CODE

What is a Residential HVAC Alteration?A residential HVAC alteration is any change to a home’s space-conditioning system that isregulated by the 2019 California’s Building Energy Efficiency Standards (Energy Code), Title 24, Part 6 which include systems that provide heating or cooling within or associated with conditioned spaces in a home. Title 24, Part 6 includes requirements for alterations affecting residential space-conditioning systems, which are generally categorized in the following three groups:

• Altered or Replaced Duct Systems • Altered Space-Conditioning System • Entirely New or Complete Replacement Space-Conditioning System

Why?As much as half of the energy used in a typical home goes to heating and cooling.Ensuring that HVAC systems are as efficient as possible can result in significant energy savings.

Relevant Code Sections

2019 California Building Energy Efficiency Standards, Title 24, Part 6:• Section 110.2 – Mandatory Requirements for Space-Conditioning Equipment• Section 150.0 – Mandatory Features and Devices

– 150.0(h) – Space-Conditioning Equipment– 150.0(i) – Thermostats– 150.0(m) – Air-Distribution and Ventilation System Ducts, Plenums, and Fans– 150.0(j) – Suction Line Insulation

• Section 150.1 – Performance and Prescriptive Compliance Approaches for Newly Constructed Residential Buildings• Section 150.2 – Energy Efficiency Standards for Additions and Alterations to Existing Low-Rise Residential Buildings

– 150.2(b)1C – New or Complete Replacement Space - Conditioning System– 150.2(b)1D – Altered Duct Systems - Duct Sealing– 150.2(b)1E – Altered Space-Conditioning System - Duct Sealing– 150.2(b)1F – Altered Space-Conditioning System - Mechanical Cooling– 150.2(b)1G – Water-Heating System

• Residential Compliance Manual, Chapter 4 – HVAC Building Requirements

What is an Altered Duct System? • Extension of Existing Ducts

– > 40 ft of extended duct system– any altered ducts in garage spaces

• Entirely New or Replacement Ducts– ≥ 75% of new duct system – Up to 25% existing duct system components may be

reused, if accessible and can be sealedNote: ≤ 40 ft of altered or extended duct does not trigger compliance documentation or duct leakage testing, unless it is in the garage. If ≤40 ft and not in garage, it must meet mandatory R-6 insulation only.

Table 150.2-A Duct Insulation R-Value

Climate Zone 1 through 10, 12 & 13 11, 14 through 16Duct R-Value R-6 R-8

BootRegister

SupplyPlenum

BootRegister

Flex Duct System, incl. starter collars, y's, etc.

>40 feet of ducts

Alteration/Extension

BootRegister

SupplyPlenum

BootRegister

Flex Duct System, incl. starter collars, y's, etc.

≥75% new duct system

New/Replacement

Figure 1: Altered or Replaced Duct Systems (Duct Sealing): §150.2(b)1D

EnergyCodeAce.com 2019 Title 24, Part 6 - Residential HVAC Alterations Page 2 of 4

What is an Altered Space-Conditioning System?If the alteration is not a complete replacement of the space conditioning system but one or more of the following components is installed or replaced, it is considered an Altered Space-Conditioning System.• Any refrigerant-containing component, including:

– Cooling coil – Condenser coil– Compressor Refrigerant piping– Refrigerant metering device– Outdoor condensing unitOR

• Air handlerAcceptable fuel types for replacement space-conditioning systems include:• Natural gas• Liquified petroleum gas• The fuel type of the system being replacedIf the fuel type of the system being replaced is gas, the replacement space-conditioning system may be a heat pump.

Figure 2: Altered Space-Conditioning System: §150.2(b)1E,F

Replacing other components is considered a repair - not an alteration. For example, replacing the blower wheel fan, but not the heat exchanger or air handler in the furnace, is a repair. Repairs do not trigger Title 24, Part 6 code requirements.

Duct Sealing and Testing (HERS measure)Duct Sealing and Testing (HERS measure) is required for both altered duct systems and new/replacement duct systems.• Extension of Existing Ducts >40 ft: The measured leakage

must be ≤ 15% of system air handler air flow. (There are alternatives to meeting the maximum 15% leakage. Consult your Building Department or Section 150.2(b)1Diib).

• Altered Space Conditioning System: The measured leakage must be ≤ 15% of system air handler air flow. (There are alternatives to meeting the maximum 15% leakage. Consult your Building Department or Section 150.2(b)1E). In addition, the system must have a cooling coil airflow > 300 CFM per ton of nominal cooling capacity or > 250 CFM per ton of nominal cooling capacity for small duct high velocity systems and verified by the HERS Rater. Refrigerant Charge verification is Prescriptively required for Climate Zones 2 and 8-15.

• New/Replacement Space Conditioning System: The Duct Sealing and Testing (HERS measure) must demonstrate a leakage rate ≤ 5% of the system air handler airflow. In addition, verification of Cooling Coil Airflow and Fan Watt Draw (HERS measure) is required. Refrigerant Charge verification is Prescriptively required for Climate Zones 2 and 8-15.

• Altered Ducts in Garage Spaces: The measured leakage must be ≤ 6% of system air handler air flow. If measured leakage is not possible an alternative would be to have all accessible leaks sealed and verified through visual inspection and smoke tested by a certified HERS Rater.

What is Entirely New versus Complete Replacement of a Space-Conditioning System?When all of the following are installed or replaced: • All the system heating/cooling components• > 75% new duct material

Figure 3: Entirely New or Complete Replacement Space-Conditioning System: §150.2(b)1C

Setback Thermostats: §110.2Only altered or new/replacement cooling systems trigger installation of setback thermostat. It is not required for heating-system-only replacements, unless the entire heating system including ducts is replaced, per Sections 150.0(i) and 150.2(b)C.

Equipment Efficiency: §110.2Most heating and cooling equipment installed in California homes is regulated by the National Appliance Efficiency Conservation Act (NAECA) and/or the California Appliance Efficiency Regulations (Title 20).

STATE OF CALIFORNIAALTERATIONS TO SPACE CONDITIONING SYSTEMSCEC-CF1R-ALT-02-E (Revised 01/19)

CALIFORNIA ENERGY COMMISSIONCERTIFICATE OF COMPLIANCE

CF1R-ALT-02-E Alterations to Space Conditioning Systems

(Page 1 of 5) Project Name:

Date Prepared:

Registration Number: Registration Date/Time: HERS Provider:

CA Building Energy Efficiency Standards - 2019 Residential Compliance January 2019

A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name:

02 Date Prepared: 03 Project Location:

04 Building Type: 05 CA City:

06 Dwelling Unit Name: 07 Zip Code:

08 Dwelling Unit CFA (ft2): 09 Climate Zone: 10 Number of Space Conditioning (SC) Systems in this Dwelling Unit:

B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10

SC System ID/Name

SC System Description of Area Served

CFA served by this SC System

(ft2):

Is the SC system a

ducted system?

Installing a refrigerant containing

component?

Installing new SC system

components?

Installing more than 40 feet of

ducts?

Installing entirely new duct system?

Installing entirely new SC

system? Alteration Type: C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib) 01 02 03

SC System ID/Name

SC System Description of Area Served

Required New Duct

R-Value

Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems -Duct insulation requirement for the new portions of supply-air and return-air ducts or plenums: R6 (CZ 1-10, 12 & 13) and R-8 (CZ 11 & 14-16). CF2R & CF3R-MCH-20-H – Duct Leakage Test -Leakage rate compliance: ≤ 15%, or ≤ 10% leakage to outside, or seal all accessible leaks Exceptions: Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 duct leakage testing requirements

STATE OF CALIFORNIADUCT LEAKAGE DIAGNOSTIC TESTCEC-CF3R-MCH-20-H (Revised 01/19) CALIFORNIA ENERGY COMMISSION

CERTIFICATE OF VERIFICATION

CF3R-MCH-20-H

Duct Leakage Diagnostic Test

(Page 1 of 3)

Project Name:

Enforcement Agency:

Permit Number:

Dwelling Address:

City:

Zip Code:

Registration Number: Registration Date/Time: HERS Provider:

CA Building Energy Efficiency Standards - 2019 Residential Compliance January 2019

A. System Information 01 Space Conditioning System Identification or Name

02 Space Conditioning System Location or Area Served

03 Indoor Unit Name

04 Building Type from CF1R

05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? 06 Verified Low Leakage Air-handling Unit Credit from CF1R?

07 Duct System Compliance Category

08 Any portions of Duct Located in Garage?

MCH-20a - Completely New Duct System

B. Duct Leakage Diagnostic Test 01 Air-Handling Unit Airflow (AHU Airflow) Determination Method

02 Condenser Nominal Cooling Capacity (ton)

03 Indoor Unit Nominal Cooling Capacity

04 Heating Capacity (kBtu/h)

05 Conditioned Floor Area Served by this HVAC System (ft2)

06 Measured AHU Airflow (cfm)

07 Duct Leakage Test Conditions

08 Duct Leakage Test Method

09 Leakage Factor

10 Calculated Target Allowable Duct Leakage Rate (cfm)

11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm)

12 Compliance Statement: 13 Notes:

STATE OF CALIFORNIA

SPACE CONDITIONING SYSTEMS, DUCTS, AND FANSCEC-CF2R-MCH-01-H (Revised 01/19)

CALIFORNIA ENERGY COMMISSION

CERTIFICATE OF INSTALLATION

CF2R-MCH-01-E

Space Conditioning Systems Ducts and Fans

(Page 1 of 9)

Project Name:

Enforcement Agency: Permit Number:

Dwelling Address:

City:

Zip Code:

Registration Number: Registration Date/Time:

HERS Provider:

CA Building Energy Efficiency Standards - 2019 Residential Compliance January 2019

A. General Information

01 Dwelling Unit Name 02 Climate Zone

03 Dwelling Unit Total Conditioned Floor

Area (ft2)

04 Number of Space Conditioning Systems in this

Dwelling Unit

05 Certificate of Compliance Type 06 Method Used to Calculate HVAC Loads

07 Calculated Dwelling Unit Sensible

Cooling Load (Btu/h)

08 Calculated Dwelling Unit Heating Load (Btu/h)

09 Dwelling Unit Number of Bedrooms

MCH-01a – Space Conditioning Systems Ducts and Fans - For use with Performance Certificate of Compliance

B. Design Space Conditioning (SC) System Component Specifications from CF1R

This table reports the space conditioning system features that were specified on the registered CF1R-PRF compliance document for this project.

01 02 03 04 05 06 07 08 09 10 11 12

Zone Name

SC System ID/Name from

CF1R SC System

Type Heating

System Type Cooling

System Type

Central Fan Ventilation

Cooling System Type

Distribution System Type

Required Thermostat

Type

Low Leakage Air-Handling Unit Status

Bypass Duct Status

Cooling Zoning Type

Cooling System

Compressor Speed Type

'

Notes:

Forms: Which & WhenIn addition to a permit, typically HVAC alterations require the following:• CF1R: Certificate of Compliance: Alteration to an HVAC System

– CF1R-ALT-02-E • Completed and signed by the installing contractor • Must be registered with a HERS Provider prior to permit

application• CF2R-MCH-01 (Tables a-e): Certificate of Installation for Space

Conditioning Systems, Ducts and Fans– Completed and signed by the installing contractor, and made

available for final inspection by building department– Must be registered with a HERS Provider prior to final

inspection• CF3R-MCH Forms: Certificate of Verification

– CF3R-MCH-20*-H: Certificate of Verification for Duct Leakage Diagnostic Test

– Completed by the HERS rater and made available for final inspection by building department

– Must be registered with a HERS Provider prior to final inspection

– CF3R-MCH-22*-H: Certificate of Verification for Fan Efficacy – Completed by the HERS rater and made available for

final inspection by building department – Must be registered with a HERS Provider prior to

final inspection– CF3R-MCH-23*-H: Certificate of Verification for Airflow Rate – Completed by the HERS rater and made available for

final inspection by building department – Must be registered with a HERS Provider prior to

final inspection– CF3R-MCH-25*-H: Certificate of Verification Refrigerant

Charge – Completed by the HERS rater and made available for

final inspection by building department – Must be registered with a HERS Provider prior to

final inspection* Correct version (e.g., “a,” “b” and “c”) varies depending upon the project scope

and approach used to demonstrate compliance

EnergyCodeAce.com 2019 Title 24, Part 6 - Residential HVAC Alterations Page 3 of 4

This program is funded by California utility customers and administered by Pacific Gas and Electric Company (PG&E), San Diego Gas & Electric Company (SDG&E®), Southern California Edison Company (SCE), and Southern California Gas Company (SoCalGas®) under the auspices of the California Public Utilities Commission.© 2019 PG&E, SDG&E, SoCalGas and SCE. All rights reserved, except that this document may be used, copied, and distributed without modification. Neither PG&E, SoCalGas, SDG&E, nor SCE — nor any of their employees makes any warranty, express or implied; or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any data, information, method, product, policy or process disclosed in this document; or represents that its use will not infringe any privately-owned rights including, but not limited to patents, trademarks or copyrights. Images used in this document are intended for illustrative purposes only. Any reference or appearance herein to any specific commercial products, processes or services by trade name, trademark, manufacturer or otherwise does not constitute or imply its endorsement, recommendation or favoring.

For More InformationPrimary Sources• Energy Code Section 110.2 – Mandatory Requirements for Space-Conditioning

Equipment energycodeace.com/site/custom/public/reference-ace-2019/Documents/

section1102mandatoryrequirementsforspaceconditioningequipment.htm• Energy Code Section 150.0 – Mandatory Features and Devices energycodeace.com/site/custom/public/reference-ace-2019/index.html#!Documents/

section1500mandatoryfeaturesanddevices.htm• Energy Code Section 150.1 – Performance and Prescriptive Compliance Approaches for

Newly Constructed Residential Buildings energycodeace.com/site/custom/public/reference-ace-2019/Documents/

section1501performanceandprescriptivecomplianceapproachesforlowr.htm• Energy Code Section 150.2 – Energy Efficiency Standards for Additions and Alterations

to Existing Low-Rise Residential Buildings energycodeace.com/site/custom/public/reference-ace-2019/index.html#!Documents/

section1502energyefficiencystandardsforadditionsandalterationsto.htm• Energy Code Residential Compliance Manual, Chapter 4 – HVAC Building Requirements energycodeace.com/site/custom/public/reference-ace-2019/Documents/

4buildinghvacrequirements.htm

California Energy Commission Information & Services• Energy Code Hotline: 1-800-772-3300 (Free) or [email protected]• Online Resource Center: www.energy.ca.gov/programs-and-topics/programs/building-energy-efficiency-

standards/online-resource-center– The Energy Commission’s main web portal for the Energy Code, including

information, documents and historical information

Additional Resources• Energy Code Ace: EnergyCodeAce.com

– An online “one-stop-shop” providing free resources and training to help appliance and building industry professionals decode and comply with Title 24, Part 6 and Title 20. The site is administered by California’s investor-owned utilities.

Of special interest: Trigger Sheets energycodeace.com/content/resources-trigger-sheets/ • Residential HVAC Alterations 2019 Please register with the site and select an industry role for your profile in order to

receive messages about all our free offerings!