LOAD
AREA
FACTOR
EXITS
ROOM NAME
PANIC
*.02
#OCC
Width
n
1A101
SIM
1
A101
SIM
0
A0.00
A1
A2A4
A3
A0.00
A1
1
A101
SIM
NameElevation
NORTH ARROWOVERLAY ARROW INDICATES TRUE NORTHSHADED AREA INDICATES PLAN NORTH
SECTION CALLOUTINDICATES A SIMILAR CONDITIONLOCATION ON SHEET
DETAIL CALLOUT
ELEVATION CALLOUT
INTERIOR ELEVATIONCALLOUTINTERIOR ELEVATION ORENTATIONILOCATION ON SHEETSHEET WHERE ELEVATION IS DRAWN
DETAIL CALLOUT
CONTROL OR DATUM POINTNAME OF ELEVATION (IF APPLICABLE)ELEVATION ABOVE FINISHED FLOOR
GRID BUBBLEGRID NUMBER
NEW CONSTRUCTION KEYNOTEKEYNOTE NUMBER (SEE LEGEND ON SHEET)
DOOR CALLOUTDOOR NUMBER
WINDOW CALLOUTWINDOW NUMBER(SEE WINDOW SCHEDULE A9.12 - A9.13)
ROOM EXITING INFORMATIONAREA (SQ FT)
OCCUPANT LOAD FACTOR
OCCUPANT LOAD (AREA DIVIDED BY LOAD FACTOR)
SHEET WHERE SECTION IS DRAWN
INDICATES A SIMILAR CONDITIONLOCATION ON SHEETSHEET WHERE SECTION IS DRAWN
LOCATION ON SHEETSHEET WHERE ELEVATION IS DRAWN
INDICATES A SIMILAR CONDITIONLOCATION ON SHEETSHEET WHERE SECTION IS DRAWN
NUMBER OF EXITS REQUIRED
DOOR EXITING INFORMATIONNUMBER OF OCCUPANTS EXITING THRU DOOR OPENING
REQUIRED EXIT WIDTH (OCCUPANT LOAD X 0.2)
PROVIDED EXIT WIDTH (IN INCHES)
PANIC EXIT HARDEWARE (WHERE OCCURS)
CASEWORK TAGMANUFACTURER REFERENCE AND MODEL NUMBER
CABINET WIDTH
CABINET HEIGHT
CABINET DEPTHWD HT DP
UWI999
AA
A101
SYMBOL DESCRIPTIONDETAIL
EXISTING METAL STUD WALL
EXISTING METAL STUD WALL, 1 HR
NOTE: SEE WALL TYPE SCHEDULE FOR ALL METAL STUD SIZES
SEMI-RECESSED FIRE EXTINGUISHERCABINET
OPERABLE LATCH @48" A.F.F.
30" x 48" ACCESSIBLE CLEAR SPACE
FLOOR SLAB DEPRESSION
SUSPENDED T-BAR CEILING WITH2'x2' OR 2'x4' CEILING TILES
GYPSUM BOARD CEILING / SOFFIT
EXISTING LIGHTING FIXTURES
EXISTING MECHANICAL REGISTERS
RECESSED CAN LIGHTS
EXISTING SUSPENDEDUTILITY LIGHT
EXISTING RECESSED LAY-INLIGHTING
SITE
ELLS
WO
RTH
LOO
P R
D.
VICTORIA LN.
HAW
ES R
D.
OCOTILLO RD.
PLEASE RECYCLE
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:04:57 AM
CONSTRUCTION DOCUMENTS
G0.10
TITLE SHEET, SYMBOLOGY ANDABBREVIATIONS
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
QUEEN CREEK HEALTH CENTERBANNER HEALTH SYSTEM
21772 South Ellsworth Loop Road, Queen Creek, AZ, 85142
APPLICABLE CODESSYMBOL LEGEND
ABBREVIATIONSØ DIAMETER OR ROUND+/- PLUS/MINUS# POUND OR NUMBER% PERCENT@ AT° DEGREE� CENTER LINE∠ ANGLE� PROPERTY LINEAB ANCHOR BOLTABS ABSOLUTEAC ASPHALTIC CONCRETEACC ACCESSIBLE WORK STATIONACOUS ACOUSTICALADJ ADJACENTAFF ABOVE FINISH FLOORALUM ALUMINIUMANSI AMERICAN NATIONAL
STANDARDS INSTITUTEARCH ARCHITECTURALBD BOARDBLDG BUILDINGBLK BLOCKBLKG BLOCKING
BTWN BETWEENC CHANNELCER CERAMICCF CUBIC FEETCFCI CONTRACTOR FURNISHED,
CONTRACTOR INSTALLEDCFOI CONTRACTOR FURNISHED,
OWNER INSTALLEDCJ CONTROL JOINTCLG CEILINGCLR CLEARCMU CONCRETE MASONRY UNITCONC CONCRETECONT CONTINUOUSCORR CORRIDORCR CLASSROOMCTSK COUNTER SUNKCTC CENTER TO CENTERd PENNYDBL DOUBLEDEL DELETEDET DETAILDF DRINKING FOUNTAINDIA DIAMETER
DIM DIMENSIONDL DOOR LOUVERDN DOWNDP DISABLED PERSON ACCESSIBLEDS DOWNSPOUTDWG DRAWINGEA EACHEJ EXPANSION JOINTELEV ELEVATIONELEC ELECTRICALEMT ELECTRICAL METAL TUBINGENCL ENCLOSUREENGR ENGINEEREOS EDGE OF SLABEQ EQUALEQPT EQUIPMENTEW EACH WAY(E) EXISTINGEXP ECPANSIONEXT EXTERIORFA FIRE ALARMFD FLOOR DRAINFDC FIRE DEPARTMENT CONNECTIONFDN FOUNDATION
FE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER W/CABINETFF FINISH FLOORFG FINISH GRADEFH FIRE HYDRANTFHC FIRE HOSE W/ CABINETFHWS FLAT HEAD WOOD SCREWFL FLOORFO FACE OFFOC FACE OF CONCRETEFOF FACE OF FINISHFOM FACE OF MASONRYFOS FACE OF STUDFS FINISH SURFACEFT FOOT OF FEETFTG FOOTINGGA GAUGEGALV GALVANIZEDGB GYPSUM BOARDGFRC GLASS FIBER REINFORCED CONCRETEGYP GYPSUMHB HOSE BIBHDWE HARDWARE
HM HOLLOW METALHOR HORIZONTALHR HOURHVAC HEATING VENTILATION AIRID INSIDE DIAMETERIN INCH OR INCHESINT INTERIORINV INVERTJBOX JUNCTION BOXJAN JANITOR CLOSETLAV LAVATORYLB(S) POUND(S)MAX MAXIMUMMB MACHINE BOLTMDF MEDIUM DENSITY FIBERBOARDMFR MANUFACTURERMH MANHOLEMIN MINIMUMMISC MISCELLANEOUSMO MASONRY OPENINGMTL METAL(N) NEWNIC NOT IN CONTRACTNO NUMBER
NR NON RATEDNTS NOT TO SCALENTS NOT TO SCALEO/ OVEROA OVERALLOC ON CENTEROD OUTSIDE DIAMETEROFCI OWNER-FURNISHED
CONTRACTOR-INSTALLEDOFOI OWNER-FURNISHED
OWNER-INSTALLEDOH OPPOSITE HANDOTO OUT TO OUTPA PUBLIC ADDRESSPE PAD ELEVATIONPERP PERPENDICULARPH PANIC HARDWAREPL PLATEPLAM PLASTIC LAMINATEPLUMB PLUMBINGPLYWD PLYWOODPM PARTITION MOUNTEDPOC POINT OF CONNECTIONPR PAIR
PREP PREPAREPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPVC POLYVINYL CHLORIDER RISER, RADIUSRD ROOF DRAINREC RECESSEDREF REFERENCEREQ REQUIREDRM ROOMRWL RAIN WATER LEADERRO ROUGH OPENINGSCHED SCHEDULESECT SECTIONSF SQUARE FEETSHT SHEETSIM SIMILARSM SURFACE MOUNTEDSMS SHEET METAL SCREWSOV SHUT OFF VALVESPEC SPECIFICATIONSST STAINLESS STEELSTD STANDARDSTL STEEL
STRUCT STRUCTURALT&B TOP AND BOTTOMTEMP TEMPORARYTO TOP OFTOC TOP OF CURBTOD TOP OF DRAINTOP TOP OF PARAPETTOPL TOP OF PLATETOR TOP OF RIDGETOS TOP OF SLABTOW TOP OF WALLTST TOP OF STEELTV TELEVISIONTYP TYPICALUC UNERCUTUNO UNLESS NOTED OTHERWISEVCT VINYL COMPOSITION TILEVERT BERTICALW WIDE FLANGEW/ WITHW/O WITHOUTWD WOODWH WATER HEATERWI WOODWORK INSTITUTE
WIN WINDOWWP WATERPROOFWS WOOD SCREWWT WEIGHTWWF WELDED WIRE FABRICx BYYD YARD
MEDICAL ROOM NAME ABBREVIATIONS: EVS: ENVIRONMENTAL SERVICES EXAM PRIM: EXAM ROOM, PRIMARY CARE EXAM PED.: EXAM ROOM, PEDIATRICS MA STATION: MEDICAL ASSISTANT STATION PROCED-PRIM: PROCEDURE ROOM, PRIMARY CARE POC: POINT OF CARE OFFICE REF.: OFFICE FOR REFERRAL PROCED-OB/GYN: PROCEDURE ROOM, OBSTETRICS &
GYNAECOLOGY.
NOTE:OTHER ABBREVIATIONS USED ON THESE DRAWINGS ARECONSIDERED STANDARDS IN THE BUILDING INDUSTRY.CONTACT ARCHITECT FOR NECESSARY CLARIFICATION.
SCOPE OF WORK
PROJECT DATAPROJECT ADDRESS:
21772 SOUTH ELLSWORTH LOOP ROADQUEEN CREEK, AZ, 85142
OCCUPANCY TYPE:B
CONSTRUCTION TYPE:II-B
AUTOMATIC SPRINKLERS THROUGHOUT:YES
NO. OF STORIES:1
SQUARE FOOTAGE OF THE FIT-OUT SCOPE:5498 SFT
REFER TO A0.10 FOR CODE ANALYSIS PLAN
1 VERIFY ALL DIMENSIONS, LOCATIONS OF EXISTINGUTILITIES, AND CONDITIONS ON THE JOB SITE PRIOR TO THESTART OF WORK OR PORTIONS OF THE WORK. NOTIFY THEARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BETWEENTHE ACTUAL FIELD CONDITIONS AND THE CONSTRUCTIONDOCUMENTS. EXISTING CONDITIONS ARE INDICATED AS ARESULT OF FIELD OBSERVATIONS, INFORMATION SHOWN ONAVAILABLE DOCUMENTS AND FIELD CONDITIONS AT THE TIMEOF PREPARATION.
2 ALL MATERIALS AND WORKMANSHIP SHALL COMPLYWITH ALL GOVERNING CODES, ORDINANCES, REGULATIONSAND LAWS.
3 THE DESIGN ADEQUACY AND SAFETY OF ERECTIONBRACING, SHORING, TEMPORARY SUPPORTS ANDSCAFFOLDING IS THE SOLE RESPONSIBILITY OF THECONTRACTOR.
4 WHERE ANY CONFLICT OCCURS BETWEEN THEREQUIREMENTS OF LAWS, CODES, ORDINANCES, RULES ANDREGULATIONS, THE MOST STRINGENT SHALL GOVERN.
5 IN NO CASE SHALL WORKING DIMENSIONS BE SCALEDFROM PLANS, SECTIONS OR DETAILS ON THE
DRAWINGS.
6 DETAILS MARKED 'TYPICAL' SHALL APPLY IN ALLCASES UNLESS SPECIFICALLY NOTED OTHERWISE.
7 WHERE NO SPECIFIC DETAIL IS SHOWN, THEFRAMING OR CONSTRUCTION SHALL BE IDENTICAL OR SIMILARTO THAT INDICATED FOR LIKE CASES OF CONSTRUCTION.
8 ENACT ALL MEASURES TO PROTECT AND SAFEGUARDALL EXISTING ELEMENTS TO REMAIN FROM BEING DAMAGED.REPLACE OR REPAIR EXISTING ELEMENTS DAMAGED BY THEEXECUTION OF THIS CONTRACT TO EQUAL OR BETTERCONDITION.
9 WHERE NEW CONSTRUCTION ABUTS EXISTINGFINISHED SURFACES, CONTRACTOR SHALL ALIGN NEWCONSTRUCTION SO THAT NEW FINISHES ARE FLUSH WITHEXISTING. MATCH EXISTING TEXTURES AND COLORS.
10 PRIOR TO THE START OF WORK THE CONTRACTORSHALL COORDINATE BETWEEN THE REQUIREMENTS OF ALLDISCIPLINES HEREIN AND BETWEEN THE REQUIREMENTS OFALL DRAWINGS AND SPECIFICATIONS IN ORDER THAT ALLITEMS SATISFACTORILY RELATE TO ONE ANOTHER. NOTIFYARCHITECT IMMEDIATELY REGARDING ANY ITEMS THATCANNOT BE COORDINATED.
11 CONTRACTOR SHALL EXCERCISE EXTREME CAUTIONIN EXCAVATING AND TRENCHING ON THIS SITE TO AVOIDEXISTING DUCTS, PIPING, CONDUIT, ETC. AND TO PREVENTHAZARD TO PERSONNEL AND/OR TO EXISTING UNDERGROUNDUTILITIES OR STRUCTURES. THE CONTRACTOR SHALLIMMEDIATELY NOTIFY THE ARCHITECT SHOULD SUCHUNIDENTIFIED CONDITIONS BE DISCOVERED. THESE DRAWINGSAND SPECIFICATIONS DO NOT INCLUDE THE NECESSARYCOMPONENTS FOR CONSTRUCTION SAFETY.
12 ALL DIMENSIONS ARE TO GRID LINES, FACE OFCONCRETE, FACE OF CONCRETE MASONRY UNITS OR FACE OFWALL FINISH, UNLESS NOTED OTHERWISE.
13 CONTRACTOR'S SAFETY BARRICADE (TEMPORARYFENCING) SHALL BE PROVIDED BY CONTRACTOR TO PROTECTPUBLIC FROM CONSTRUCTION ACTIVITIES. CONTRACTOR'SSAFETY BARRICADE SHALL PROTECT AND SECURECONSTRUCTION AREA. TEMPORARY FENCING SHALL ALSO BEPROVIDED BY CONTRACTOR TO PROTECT AND SECURESTORAGE YARDS. EXACT LOCATION OF CONTRACTOR'SSAFETY BARRICADE AND OTHER TEMPORARY FENCING SHALLBE APPROVED BY THE CONSTRUCTION MANAGER PRIOR TOINSTALLATION.
GENERAL NOTES14 CUTTING, BORING, SAWCUTTING OR DRILLINGTHROUGH THE EXISTING OR NEW STRUCTURAL ELEMENTS ISNOT TO BE STARTED UNTIL THE DETAILS HAVE BEEN REVIEWEDAND APPROVED BY THE ARCHITECT AND STRUCTURALENGINEER IF DETAILS ARE NOT SHOWN OR DO NOT CONFORMTO THE APPROVED DRAWINGS.
15. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OFFIRE SAFETY DURING CONSTRUCTION AS INDICATED IN THE2012 IFC, CHAPTER 14. THESE INCLUDE BUT ARE NOT LIMITEDTO: NO SMOKING SIGNS, STORAGE OF FLAMMABLE LIQUIDS,FIRE WATCHES, CUTTING AND WELDING, LEAKAGE AND SPILLTREATMENT, FLAMMABLE GASES, EXPLOSIVES, OWNER'SRESPONSIBILITY FOR FIRE PROTECTION, MEANS OF EGRESSDURING CONSTRUCTION, TEMPORARY STANDPIPES,TEMPORARY WATER SUPPLIES, AND ROOFING OPERATIONS.
16. AN APPROVED PORTABLE FIRE EXTINGUISHER SHALLBE PROVIDED IN EVERY STORAGE AND CONSTRUCTION SHED.THE BUILDING OFFICIAL IS AUTHORIZED TO REQUIREADDITIONAL APPROVED PORTABLE FIRE EXTINGUISHERSWHERE SPECIAL HAZARDS EXIST, SUCH AS FLAMMABLE ORCOMBUSTIBLE LIQUID STORAGE HAZARDS. FIREEXTINGUISHERS SHALL COMPLY WITH SECTION 906.REFERENCE IBC SECTION 3309.1 AND IFC SECTION 906.1.4 AND1414.1.
17. OPERATION OF SPRINKLER CONTROL VALVES SHALLBE PERMITTED ONLY BY PROPERLY AUTHORIZED PERSONNELAND SHALL BE ACCOMPANIED BY NOTIFICATION OF DULYDESIGNATED PARTIES. WHEN THE SPRINKLER PROTECTION ISBEING REGULARLY TURNED OFF AND ON TO FACILITATECONNECTION OF NEWLY COMPLETED SEGMENTS, THESPRINKLER CONTROL VALVES SHALL BE CHEKCED AT THE ENDOF EACH WORK PERIOD TO ASCERTAIN THAT PROTECTION IS INSERVICE. REFERENCE 2012 IFC SECTION 1414.2 AND IBCSECTION 3312.2.
18. AN APPROVED WATER SUPPLY FOR FIREPROTECTION, EITHER TEMPORARY OR PERMANENT, SHALL BEMADE AVAILABLE AS SOON AS COMBUSTIBLE MATERIAL ARRIVESON SITE. REFERENCE 2012 IFC SECTION 1412.1 AND IBCSECTIONS 3313.
No. Description Date
INTERNATIONAL BUILDING CODE, 2012 EDITIONINTERNATIONAL RESIDENTIAL CODE, 2012 EDITIONINTERNATIONAL MECHANICAL CODE, 2012 EDITIONNATIONAL ELECTRICAL CODE, 2011 EDITIONINTERNATIONAL PLUMBING CODE, 2012 EDITIONINTERNATIONAL FUEL GAS CODE, 2012 EDITIONINTERNATIONAL EXISTING BUILDING CODE, 2012 EDITIONINTERNATIONAL ENERGY CONSERVATION CODE, 2012 EDITIONINTERNATIONAL PROPERTY MAINTENANCE CODE, 2012 EDITIONINTERNATIONAL URBAN-WILDLIFE INTERFACE CODE, 2012 EDITIONINTERNATIONAL FIRE CODE, 2012 EDITION
HMC ARCHITECTSGENERAL
1001 N. 3RD AVENUE, STUDIO 2,PHOENIX, AZ, 85003
602 575 2055HMC Drawing
Order NUMBER NAME REV DATE01 - General 1.0 TITLE SHEET, SYMBOLOGY AND
ABBREVIATIONS
NUMBER NAMEA0.10 LIFE SAFETY PLAN - CODE ANALYSISA2.1 KEY FLOOR PLANA2.1E FLOOR PLAN - SECTOR EA2.1F FLOOR PLAN - SECTOR FA2.3E FURN. & EQUIP. PLAN - SECTOR EA2.3F FURN. & EQUIP. PLAN - SECTOR FA3.01 REFLECTED CEILING PLANA7.01 FLOOR FINISH,WALL ACCENT PAINT &
WALL PROTECTION PLANA8.01 ACCESSIBILITY NOTESA8.02 TYPICAL MOUNTING HEIGHTS AND
DIMENSIONING CONVENTIONSA8.03 INTERIOR ELEVATIONSA8.04 INTERIOR ELEVATIONSA8.05 INTERIOR ELEVATIONS & ROOM FINISH
SCHEDULEA10.01 MILLWORK DETAILSA10.02 MILLWORK DETAILSA10.03 MISCELLANEOUS DETAILS
HMC ARCHITECTSARCHITECTURAL
1001 N. 3RD AVENUE, STUDIO 2,PHOENIX, AZ, 85003
602 575 2055
THIS PROJECT FOR BANNER HEALTH CONSISTS OF INSTALLING FLOORING,MILLWORK, MILLWORK-MOUNTED PLUMBING FIXTURES, OTHERMISCELLANEOUS FINISHES IN THE EXISTING BANNER HEALTH CENTER.ALL PATIENTS ARE CAPABLE OF SELF-PRESERVATION AT ALL TIMES.
THERE WILL BE NO INCREASE IN FOOTPRINT TO THE EXISTING BUILDING.THERE WILL ALSO BE NO SITE IMPROVEMENTS AS A PART OF THIS SCOPE OFWORK.
279 SF
ELEC
1
1/300
MECH/ELEC
385 SF
CONFERENCE
26
1/15
B
392 SF
LOUNGE
27
1/15
B
12050 SF
BUSINESS
121
1/100
B
328 SF
MDF
2
1/300
MECH/ELEC
1159 SF
WAITING
78
1/15
B
101 SF
WAITING
7
1/15
B
442 SF
MECH
2
1/300
MECH/ELEC
5498 SF
BUSINESS
55
1/100
B
NOTE:MECH AREA INCLUDES AREA OFDEMARK AND PREACT RISER
205' MAX.TRAVEL DISTANCE
145' TRAVELDISTANCE POINT
TO EXIT
45' T
RAV
EL D
IST.
POIN
T TO
PO
INT
70' TRAVEL DISTANCEPOINT TO EXIT
82' TRAVEL DISTANCEPOINT TO EXIT
22' - 6"
EXIT WIDTH PROVIDED
EXIT WIDTH REQUIRED (INCHES)NUMBER OF OCCUPANTS0
0
0
0
0
0
0
0 OCCUPANT LOAD
OCCUPANCY GROUP
USE
SQUARE FOOTAGE OF ROOM
OCCUPANT LOAD FACTOR (OLF)
PATH OF EXIT TRAVEL DISTANCE
FE
1 HR FIRE RATED BARRIER EXTENDED TO UNDERSIDE OF DECK
FIRE EXTINGUISHER CABINET
EXIT, ACCESS TO EXIT
1. REFER TO SHEET G0.10 FOR TYPICAL SYMBOLS AND ABBREVIATIONS
PLEASE RECYCLE
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:03:18 AM
CONSTRUCTION DOCUMENTS
A0.10
LIFE SAFETY PLAN - CODE ANALYSIS
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
1/16" = 1'-0"
2LIFE SAFETY PLAN
90
32
18
94
64
19
90
64
18
25
32
5
20
32
4
PROJECT CODE SUMMARY 1NTS
SCOPE OF WORKTHIS PROJECT FOR BANNER HEALTH CONSISTS OF INSTALLING FLOORING,MILLWORK, MILLWORK-MOUNTED PLUMBING FIXTURES, OTHERMISCELLANEOUS FINISHES IN THE EXISTING BANNER HEALTH CENTER.ALL PATIENTS ARE CAPABLE OF SELF-PRESERVATION AT ALL TIMES.
THERE WILL BE NO INCREASE IN FOOTPRINT TO THE EXISTING BUILDING.THERE WILL ALSO BE NO SITE IMPROVEMENTS IN THIS SCOPE OF WORK.
BUILDING AREA CALCULATIONSEXTERIOR
LEVEL BUILDING AREA COVERED GROSS AREA
FIRST LEVEL 20,294 691 20,985
TOTAL GROSS BUILDING AREA (EXISTING) 20,985 SF
BUILDING CLASSIFICATION
MINIMUM FIRE RESISTIVE REQUIREMENTS(PER 2012 IBC TABLE 601)
ELEMENT REQUIRED RATING PROVIDED RATING
PRIMARY STRUCTURAL FRAME 0 NR 0NRBEARING WALLS - EXTERIOR 2 HR *N/ABEARING WALLS - INTERIOR 0 NR 0NRNON BEARING WALLS AND PARTITIONS - EXTERIOR 0 NR 0NRNON BEARING WALLS AND PARTITIONS - INTERIOR 0 NR 0NRFLOOR CONSTRUCTION AND SECONDARY MEMBERS 0 NR 0NRROOF CONSTRUCTION AND SECONDARY MEMBERS 0 NR 0NR
* N/A - ALL EXTERIOR WALLS ARE NON-LOAD BEARING
FOR U.L. LISTINGS REFER TO A10. SERIES DRAWINGS
MAXIMUM TRAVEL DISTANCE TO EXITSPER IFC 2012B OCCUPANCY, FULLY SPRINKLERED 300 FEET
COMMON PATH OF TRAVELPER 2012 IFC 100 FEETALLOWABLE OVERLAPPING TRAVEL DISTANCE FOR TWO EXIT PATHS N/A
REFER TO LIFE SAFETY PLAN FOR ACTUAL MEASURED DISTANCES THROUGHOUT BUILDING
FIRE SUPPRESSIONTHE FACILITY IS BE PROTECTED BY A SUPERVISED AUTOMATIC SPRINKLER SUPRESSIONSYSTEM PER IFC 2012.
A CLASS 1 AUTOMATIC WET STANDPIPE SYSTEM SHALL BE PROVIDED PER IFC 2012
HAND HELD FIRE EXTINGUISHERS WILL BE PROVIDED PER CODE AT 75' TRAVEL DISTANCEAND MAXIMUM FLOOR AREA OF 3,000 SF. REFER TO LIFE SAFETY PLAN FOR LOCATIONS.
REFER TO EACH DISCIPLINES DRAWINGS FOR ADDITIONAL FIRE SUPPRESSIONREQUIREMENTS.
OCCUPANT LOAD CALCULATIONS(PER 2012 IBC CHAPTER 10 AND TABLE 1004.1.1)
OCCUPANT LOAD FACTOR (SF/PERSON)
BUSINESS AREAS (INCLUDES CLINIC - OUTPATIENT) 100 GROSSASSEMBLY WITHOUT FIXED SEATS, UNCONCENTRATED 15 NETACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 GROSS
OCCUPANT LOAD BY LEVEL
OCCUPANCY PER LEVEL OCCUPANT LOAD
FIRST LEVEL
B TOTAL OCCUPANTS 319
TOTAL OCCUPANT LOAD 319
FOR MORE DETAILED OCCUPANT LOAD DISTRIBUTION PER LEVEL,REFER TO THE OCCUPANT LOAD DIAGRAM ON THE LIFE SAFETY PLAN THIS SHEET
EXITING REQUIREMENTSMINIMUM EXIT WIDTH PER PERSON
STAIRWAYS N/AOTHER EGRESS COMPONENTS 0.2
REQUIRED EGRESS
OCCUPANT EGRESS WIDTH (INCHES)LEVEL LOAD PER LEVEL (0.2)
FIRST LEVEL 319 64"
EGRESS PROVIDED
EGRESS WIDTH (INCHES)LEVEL # OF STAIRS (0.2)
FIRST LEVEL N/A B 224"
TOTAL EXIT WIDTH PROVIDED: B 224"
FOR MORE DETAILED EGRESS REQUIREMENTS PER LEVEL,REFER TO THE EXITING DIAGRAM ON THE LIFE SAFETY PLANS.
PLUMBING CALCULATIONSPER 2012 UPC - SECTION 4.12
FIRST LEVEL
OCCUPANT LOAD TOTAL: 319
REQUIRED PLUMBING FIXTURES TOTAL
WATER CLOSETS 10LAVATORIES 7DRINKING FOUNTAINS 3OTHER (SERVICE SINK) 1
PROVIDED PLUMBING FIXTURESTOTAL
WATER CLOSETS 11LAVATORIES 10DRINKING FOUNTAINS 4OTHER (SERVICE SINK) 1
CODE ANALYSIS BASED ON 2012 IBC
No. Description Date
(PER 2012 IBC CHAPTERS 3,4,5, AND 6)
BASIC OCCUPANCY GROUPS(PER 2012 IBC CHAPTER 3)
OCCUPANCY GROUP B 5,498 SFBUSINESS (FIT OUT PHASE)
REFER TO LIFE SAFETY PLAN FOR OCCUPANCY GROUP LOCATIONS
CONSTRUCTION TYPE(PER 2012 IBC CHAPTER 6 AND TABLE 601)
CONSTRUCTION TYPE IIB
BASIC ALLOWABLE AREA PER FLOOR(PER 2012 IBC TABLE 601)OCCUPANCY GROUP B 19,000 GSF
AREA INCREASE JUSTIFICATION UNLIMITED
PER 2012 IBC 508.4.2 ?
BASIS OF ALLOWABLE AREA INCREASETWO STORY, AUTOMATIC FIRE SPRINKLERS THROUGHOUT,PUBLIC WAYS / YARD NOT LESS THAN 60 FEET IN WIDTH
BASIC ALLOWABLE HEIGHT(PER 2012 IBC TABLE 601)OCCUPANCY GROUP B 3 STORIES, 55 FEETOCCUPANCY GROUP S-1 2 STORIES, 55 FEET
HEIGHT INCREASE JUSTIFICATION(PER 2012 IBC 504.2) ?OCCUPANCY GROUP B 4 STORIES, 75 FEETOCCUPANCY GROUP S-1 3 STORIES, 75 FEET
BASIS OF ALLOWABLE HEIGHT INCREASEAUTOMATIC FIRE SPRINKLERS THROUGHOUT
ACTUAL HEIGHT 1STORY/ 27'-4"
ABOVE GRADE
EXISTING STRUCTURE PERMITTED UNDER:PERMIT #:
TT
E
C
B
A
765
4321
A
B
C
D
E
F
D
27' - 8" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0"
27' -
8"
27' -
8"
27' -
8"
27' -
8"
2' -
10"
1' -
2"10
' - 0
"11
' - 1
0"2'
- 8"
4' -
8"2'
- 8"
4' -
8"2'
- 8"
4' -
8"2'
- 8"
18' -
8"
2' -
8"7'
- 4"
2' -
8"16
' - 3
"6'
- 4"
10' -
11"
115'
- 5"
6' - 10" 3' - 4" 2' - 8" 3' - 4" 4' - 0" 6' - 4" 32' - 2" 6' - 0" 11" 6' - 0" 2' - 2" 6' - 0" 11" 6' - 0" 62' - 5" 6' - 0" 1' - 4" 6' - 0" 1' - 4" 6' - 0" 2' - 0" 5' - 4" 7"1' - 9" 2' - 1"
7' -
4"2'
- 8"
4' -
8"3'
- 4"
6' -
0"2'
- 8"
7' -
4"2'
- 8"
7' -
4"2'
- 8"
7' -
4"2'
- 8"
7' -
4"2'
- 8"
10' -
0"
3' -
4"
2' -
0"
2' -
8"6'
- 0"
2' -
8"6'
- 0"
2' -
8"10
' - 1
1"1'
- 2"
1' -
6"
6' - 0" 25' - 8" 15' - 4"
2' - 0"
8' - 0" 18' - 0" 12' - 0" 18' - 0" 12' - 0" 18' - 0" 12' - 0" 18' - 0" 6' - 0" 6' - 0"
5' - 6"
189' - 2"
10.26
7'-6
1/2
"
7'-6
1/2
"
7 1/4"
OFFICE, PROV.SHARED
188
OFFICE, PROV.SHARED
187
PROCED-PRIM
186
PROCED-OB/GYN
185
CORRIDOR135
CHARTING A135B
CHARTING B190C
CORRIDOR190A
EXAM-PRIM
192
EXAM-PRIM
194
EXAM-PRIM
196
EXAM-PRIM
199
EXAM-PRIM
200
CORRIDOR159
POC198
TLT-PATADA
203
MA STATION-TYP.
197
EXAM-PRIM
195
EXAM-PRIM
220
TLT-PATADA
213
TLT-STF, ADA217
EXAM-PRIM
218
EXAM-PRIM
219
EXAM-PRIM
221
EXAM-PRIM
223
EXAM-PRIM
225
CORRIDOR215A
EXAM-PRIM
222
EXAM-PRIM
193
EXAM-PRIM
191
EXAM-PRIM
224
COPY/PRINT/FAX
204
ALCOVE,SCALE
216
CORRIDOR215B
MANAGEROFFICE
121
OFFICEREF.
211
CHECK IN208
CHECKOUT
209
CHECKOUT
207
CORRIDOR190B
A. REFER TO SHEET G0.10 FOR PROJECT GENERAL NOTES, TYPICAL SYMBOLS ANDABBREVIATIONS.
B. REFER TO A0.10 SHEET SERIES FOR ALL CODE AND LIFE SAFETY INFORMATION.C. REFER TO A9.10 SHEET SERIES FOR ALL PARTITIONS TYPES, NOTES AND SCHEDULE
INFORMATIOND. REFER TO A2.3A- A2.3F SHEET SERIES FOR EQUIPMENT LOCATIONS, CONTRACTOR
SHALL PROVIDE ALL BACKING AND SUPPORT REQUIRED FOR ALL EQUIPMENT ANDACCESSORIES INDICATED IN DOCUMENTS AS DONE WITH EXISTING EQUIPMENT.
E. REFER TO A7.10 SHEET SHEET SERIES FOR ALL INTERIOR FINISH AND WALLPROTECTION INFORMATION.
F. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF ALL DOOR OPENERS, CARDREADERS, AND KEY SWITCHES, COORDINATE LOCATION WITH ARCHITECT PRIOR TOINSTALLATION AND ROUTING OF ELECTRICAL.
G. ALL PARTITION TYPES ARE TO BE "0A3A" U.O.N. AND ALL COLUMN SURROUNDS ARE TOBE PARTITION TYPE "0G3" U.O.N. THE DIMESIONS OF THE SURROUNDS ARE TO BE 10"OFF OF THE GRIDLINE TO FINISH FACE OF GYP. BD. U.O.N.
H. DESIGNATED SHELL SPACES ARE TO BE FINISHED OUT TO MEET MINIMUM CODEREQUIREMENTS FOR UNOCCUPIED SPACES. IN SUCH SPACES, CONTRACTOR SHALLPROVIDE TAPED GYP. BD. AT INTERIOR SIDE OF EXTERIOR STUD WALL FRAMING.
I. AT PARTITIONS WHERE TERRAZZO BASE IS SCHEDULED, CONTRACTOR SHALL PROVIDEADDITIONAL FACE LAYER OF 1/2" GYP. BD.
J. PROVIDE COAT HOOKS ON THE BACKS OF ALL TOILET STALL DOORS.K. PROVIDE 1/2" REVEAL AT ALL CONTACTS OF DISSIMILAR MATERIAL, INCLUDING BUT NOT
LIMITED TO EXTERIOR OPENING SYSTEM, GYP. BD. TO MASONRY VENEER.L. FIRE STOPPING SEALANT SHALL BE REQUIRED AT ALL SMOKE RATED AND FIRE RATED
PARTITIONS.M. ALL MANUFACTURER'S INSTALLATION INSTRUCTIONS, ASTM STANDARDS, AND ICBO
AND ICC ER REPORTS SHALL BE PROVIDED TO THE INSPECTOR AT THEIR REQUEST ATTIME OF INSPECTION.
EXISTING NON-RATED STUD WALL
EXISTING 1-HOUR FIRE-RATED STUD WALL
EXISTING TO REMAIN. PROTECT AND PRESERVE DURING THE COURSE OFCONSTRUCTION.
n
n
PLEASE RECYCLE
Key Plan
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:03:26 AM
CONSTRUCTION DOCUMENTS
A2.1
KEY FLOOR PLAN
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
1/8" = 1'-0"
1KEY FLOOR PLAN
F
E
D
C
B
A
F
E
D
C
B
A
GRAPHIC LEGEND
No. Description Date
NOTES
E
C
765
A8.04
1-A
1-D
1-C
1-BA8.03
2D
2C
2B
2A
A8.03
2D
2A
2B
2C
A8.04
4-A
4-D
4-C
4-B
A8.03 1C
1A
1B
A8.03 5A
5B
210B
211
217
218
159A
200
199
196
206A
206B
213203
204171
101C 101D
A8.03 7A
A8.037B A8.03
4B
4A
A8.03 6AA8.036B
----
1A2
.1F
101E
159C
D
3' -
7 1/
2"8'
- 4"
5' -
0"5'
- 8
3/4"
8' -
0 1/
2"
30' - 0" 30' - 0"
7' - 7 3/4" 2' - 10 1/4" 4' - 0" 2' - 10 1/4" 7' - 7 3/4"
5' - 0" 7' - 3 1/2" 3' - 2 3/4" 4' - 0" 3' - 0 1/2" 7' - 5 1/4"
8' - 7" 5' - 0" 13' - 0" 12' - 0" 5' - 0"
3' - 6" 3' - 0" 3' - 6" 12' - 6"
4' -
0"
4' -
0"
1' - 3 1/4"
3' - 0"
3' - 0"
7'-1
0 1/
2"
3'-0" 4'-6"
6' - 7 1/2" 3' - 4" 3' - 0 3/4"
5' - 10 1/4" 4' - 6" 2' - 2"
5'-0"
EXAM-PRIM
219
EXAM-PRIM
218
TLT-STF, ADA217
CORRIDOR159
MANAGEROFFICE
121
OFFICEREF.
211
CORRIDOR215B
CHECKOUT
209
CHECK IN208
CHECKOUT
207
COPY/PRINT/FAX
204
ALCOVE,SCALE
216
CORRIDOR159
POC198
TLT-PATADA
213
TLT-PATADA
203
MA STATION-TYP.
197
EXAM-PRIM
196
EXAM-PRIM
199
EXAM-PRIM
200
CORRIDOR159
CORRIDOR190B
A. REFER TO SHEET G0.10 FOR PROJECT GENERAL NOTES, TYPICAL SYMBOLS ANDABBREVIATIONS.
B. REFER TO A0.10 SHEET SERIES FOR ALL CODE AND LIFE SAFETY INFORMATION.C. REFER TO A9.10 SHEET SERIES FOR ALL PARTITIONS TYPES, NOTES AND SCHEDULE
INFORMATIOND. REFER TO A2.3A- A2.3F SHEET SERIES FOR EQUIPMENT LOCATIONS, CONTRACTOR
SHALL PROVIDE ALL BACKING AND SUPPORT REQUIRED FOR ALL EQUIPMENT ANDACCESSORIES INDICATED IN DOCUMENTS AS DONE WITH EXISTING EQUIPMENT.
E. REFER TO A7.10 SHEET SHEET SERIES FOR ALL INTERIOR FINISH AND WALLPROTECTION INFORMATION.
F. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF ALL DOOR OPENERS, CARDREADERS, AND KEY SWITCHES, COORDINATE LOCATION WITH ARCHITECT PRIOR TOINSTALLATION AND ROUTING OF ELECTRICAL.
G. ALL PARTITION TYPES ARE TO BE "0A3A" U.O.N. AND ALL COLUMN SURROUNDS ARE TOBE PARTITION TYPE "0G3" U.O.N. THE DIMESIONS OF THE SURROUNDS ARE TO BE 10"OFF OF THE GRIDLINE TO FINISH FACE OF GYP. BD. U.O.N.
H. DESIGNATED SHELL SPACES ARE TO BE FINISHED OUT TO MEET MINIMUM CODEREQUIREMENTS FOR UNOCCUPIED SPACES. IN SUCH SPACES, CONTRACTOR SHALLPROVIDE TAPED GYP. BD. AT INTERIOR SIDE OF EXTERIOR STUD WALL FRAMING.
I. AT PARTITIONS WHERE TERRAZZO BASE IS SCHEDULED, CONTRACTOR SHALL PROVIDEADDITIONAL FACE LAYER OF 1/2" GYP. BD.
J. PROVIDE COAT HOOKS ON THE BACKS OF ALL TOILET STALL DOORS.K. PROVIDE 1/2" REVEAL AT ALL CONTACTS OF DISSIMILAR MATERIAL, INCLUDING BUT NOT
LIMITED TO EXTERIOR OPENING SYSTEM, GYP. BD. TO MASONRY VENEER.L. FIRE STOPPING SEALANT SHALL BE REQUIRED AT ALL SMOKE RATED AND FIRE RATED
PARTITIONS.M. ALL MANUFACTURER'S INSTALLATION INSTRUCTIONS, ASTM STANDARDS, AND ICBO
AND ICC ER REPORTS SHALL BE PROVIDED TO THE INSPECTOR AT THEIR REQUEST ATTIME OF INSPECTION.
EXISTING NON-RATED STUD WALL
EXISTING 1-HOUR FIRE-RATED STUD WALL
n
n
PLEASE RECYCLE
Key Plan
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:03:39 AM
CONSTRUCTION DOCUMENTS
A2.1E
FLOOR PLAN - SECTOR E
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
1/4" = 1'-0"
1FLOOR PLAN - SECTOR E
F
E
D
C
B
A E
NO. KEYNOTE
GRAPHIC LEGEND
No. Description Date
C
B
A
765
A8.05
3-A
3-B
3-C
3-D A8.05
3-A
3-C
3-BA8.05
4-A
4-D
4-C
4-BA8.05
4-A
4-D
4-C
4-B
135A
221
223
225
188187186185
184
191
193
195
220
222
224
196
194
192
----
1A2
.1E
A8.04
2-A
2-B
2-C
2-D
135C
6.05
6.05
EXAM-PRIM
219
MA STATION-TYP.
197
EXAM-PRIM
196
A. REFER TO SHEET G0.10 FOR PROJECT GENERAL NOTES, TYPICAL SYMBOLS ANDABBREVIATIONS.
B. REFER TO A0.10 SHEET SERIES FOR ALL CODE AND LIFE SAFETY INFORMATION.C. REFER TO A9.10 SHEET SERIES FOR ALL PARTITIONS TYPES, NOTES AND SCHEDULE
INFORMATIOND. REFER TO A2.3A- A2.3F SHEET SERIES FOR EQUIPMENT LOCATIONS, CONTRACTOR
SHALL PROVIDE ALL BACKING AND SUPPORT REQUIRED FOR ALL EQUIPMENT ANDACCESSORIES INDICATED IN DOCUMENTS AS DONE WITH EXISTING EQUIPMENT.
E. REFER TO A7.10 SHEET SHEET SERIES FOR ALL INTERIOR FINISH AND WALLPROTECTION INFORMATION.
F. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF ALL DOOR OPENERS, CARDREADERS, AND KEY SWITCHES, COORDINATE LOCATION WITH ARCHITECT PRIOR TOINSTALLATION AND ROUTING OF ELECTRICAL.
G. ALL PARTITION TYPES ARE TO BE "0A3A" U.O.N. AND ALL COLUMN SURROUNDS ARE TOBE PARTITION TYPE "0G3" U.O.N. THE DIMESIONS OF THE SURROUNDS ARE TO BE 10"OFF OF THE GRIDLINE TO FINISH FACE OF GYP. BD. U.O.N.
H. DESIGNATED SHELL SPACES ARE TO BE FINISHED OUT TO MEET MINIMUM CODEREQUIREMENTS FOR UNOCCUPIED SPACES. IN SUCH SPACES, CONTRACTOR SHALLPROVIDE TAPED GYP. BD. AT INTERIOR SIDE OF EXTERIOR STUD WALL FRAMING.
I. AT PARTITIONS WHERE TERRAZZO BASE IS SCHEDULED, CONTRACTOR SHALL PROVIDEADDITIONAL FACE LAYER OF 1/2" GYP. BD.
J. PROVIDE COAT HOOKS ON THE BACKS OF ALL TOILET STALL DOORS.K. PROVIDE 1/2" REVEAL AT ALL CONTACTS OF DISSIMILAR MATERIAL, INCLUDING BUT NOT
LIMITED TO EXTERIOR OPENING SYSTEM, GYP. BD. TO MASONRY VENEER.L. FIRE STOPPING SEALANT SHALL BE REQUIRED AT ALL SMOKE RATED AND FIRE RATED
PARTITIONS.M. ALL MANUFACTURER'S INSTALLATION INSTRUCTIONS, ASTM STANDARDS, AND ICBO
AND ICC ER REPORTS SHALL BE PROVIDED TO THE INSPECTOR AT THEIR REQUEST ATTIME OF INSPECTION.
EXISTING NON-RATED STUD WALL
EXISTING 1-HOUR FIRE-RATED STUD WALL
n
n
PLEASE RECYCLE
Key Plan
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:03:57 AM
CONSTRUCTION DOCUMENTS
A2.1F
FLOOR PLAN - SECTOR F
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
1/4" = 1'-0"
1FLOOR PLAN - SECTOR F
F
E
D
C
B
A
F
NO. KEYNOTE
6.05 SOLID-SURFACE COUNTERTOP
GRAPHIC LEGEND
No. Description Date
E
C
765
DEFIBCAB
CLOCK
WHTBRD06
PHONE01
WSTCN
REFRIG02BIOWST04
REFRIG03
TMPMONPOC
ANALYZR02
MCROSCPGLVBOX
SHARPS
PPRTWLSOAP
ANALYZR01
ANALYZR01COMPUTR
CNTRFUG
WHTBRD09
TLTPPR
SOAPPPRTWL
NAPDSPL
SOAPPPRTWL
TLTPPRNAPDSPL
NAPDSPL
D
SCANNER
MFP03
WSTCN
COMPUTR
PHONE01
CLOCK
SANITZR
PHYSMONSTDIOMTR01
THERMOMTR
DEFIB
CH3DCH1C
CH1CCH1C
CH3D
CH1CCH1CCH1C
CH3D
CH1CCH3D
CH1C
CH1CCH1C
CH3DCH1C
CH3DCH1C
CH1C
CH1CT1T1
T1
T1
T1
WSTCN12
SANITZR
PHYSMON
SCALE01SCALE02
STDIOMTR01
THERMOMTR
WSTCN
TSKCHRTSKCHR TSKCHR TSKCHR
LBLPRNTR
COMPUTRPHONE01
WEBCAM COMPUTRPHONE01
LBLPRNTR
SCANNER
COMPUTRPHONE01
WSTCN
WSTCNWSTCN
SCANNER
COMPUTRWEBCAM
PHONE01
WEBCAM
WSTCN
SHRDR
MFP03
SAFE
WSTCN08
BROOMMOPBKT
VACUUMDUSTPN
MFP03WSTCN08
WSTCNTSKCHR
LAPTOP
PHONE01
LBLPRNTR
SCANNER
LAPTOPPHONE01
TSKCHRWSTCN
WSTCNTSKCHR
LAPTOPPHONE01
SCANNER
LBLPRNTR
PHONE01
LAPTOP
TSKCHRWSTCN
CH8CH8
CH8T3
CH8
TSKCHR
CH9
CH9
CH9
CH9
TSKCHR
COMPUTR
PHONE01
SCANNER
MFP02PTRSTNDWSTCN
TLTSTCVR TLTSTCVR
WSTCN07
WSTCNLID
WSTCN07WSTCNLID
TLTPPR
TLTSTCVR
WSTCNLIDWSTCN07
WS1
WS3
PASS-THRU
SCALE01 CH5
WSTCN
n
n
PLEASE RECYCLE
Key Plan
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:04:08 AM
CONSTRUCTION DOCUMENTS
A2.3E
FURN. & EQUIP. PLAN - SECTOR E
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
1/4" = 1'-0"
1FURNITURE AND EQUIPMENT PLAN - SECTOR E
F
E
D
C
B
A E
No. Description Date
B
A
765
CRTSTLZRINCUBTRGLVBOX
1A2
.3E
PPRTWLSOAP
WSTCN07
PHONE01LAPTOPTSKCHR
SCANNERWSTCN
MFP03WSTCN08
PHONE01LAPTOP
WSTCNTSKCHRLAPTOP
LAPTOP
CMPTR02
PHONE01LAPTOP
WSTCN
WSTCN08WSTCN
PRNTR
WSTCN
LAPTOPPHONE01
CLOCK
PHONE01LAPTOP
TSKCHR TSKCHR
TSKCHR
PHONE01LAPTOP
WSTCN
WSTCN08WSTCN
PRNTR
WSTCN
LAPTOPPHONE01
CLOCK
PHONE01LAPTOP
TSKCHRTSKCHR
TSKCHR
EXAMTBL2
IVSTND
STOOL
SOAPPPRTWL
OPHTHOTO
SHARPSBIOWST04
MAYO
CH5
EXAMLT01
WSTCN13
WS6 WS6
CH5
n
n
PLEASE RECYCLE
Key Plan
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:04:26 AM
CONSTRUCTION DOCUMENTS
A2.3F
FURN. & EQUIP. PLAN - SECTOR F
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
1/4" = 1'-0"
1FURNITURE AND EQUIPMENT PLAN - SECTOR F
F
E
D
C
B
A
F
No. Description Date
E
C
B
A
765
10' - 8" 10' - 8"
8' - 6"
8' - 0" 8' - 0"
8' - 6"
8' - 0"
8' - 6" 8' - 6"
D
8' - 6"
8' - 0"
8' - 6"
8' - 6"
8' - 6"
8' - 6"
8' - 6"
8' - 6"
8' - 6"
11' - 4" 11' - 4"
10' - 0"
PT-6
EQEQ
EQ
1. REFER TO SHEET G0.10 FOR TYPICAL SYMBOLS AND ABBREVIATIONS.2. ALL CEILING HEIGHTS TO BE 9'-0" AFF UNLESS NOTED OTHERWISE.
EXISTING 4" WOODWORKS LINEAR WOOD PLANKCEILING SYSTEM
EXISTING 2'-0" X 2'-0" ACT
GYP. BD. CEILING/SOFFIT - REFERTO SPECIFICATIONS
EXPOSED TO STRUCTURE
EXIT SIGN/DIRECTION
EXISTING LAY-IN RADIANT PANEL CEILING
EXISTING AIR DIFFUSERS
EXISTING LIGHT FIXTURES
0'-0" CEILING HEIGHT
A. REFER TO G0.10 SHEET FOR ARCHITECTURAL DRAWING REFERENCE,MATERIAL SYMBOLS, GENERAL NOTES, TYPICAL ARCHITECTURALCONFIGURATIONS AND ABBREVIATIONS USED ON THIS DRAWING.
B. VERTICAL ELEVATIONS PROVIDED ON THIS DRAWING ARE SHOWN RELATIVETO FINISH FLOOR REFERENCE ELEVATION, UNO.
C. CEILING SUBCONTRACTOR SHALL PROVIDE APPROPRIATE BLOCKING ANDTEES FOR ALL CEILING MOUNTED EQUIPMENT, INCLUDING BUT NOT LIMITEDTO: MECHANICAL GRILLES AND DIFFUSERS, ELECTRICAL FIXTURES, ACCESSDOORS/PANELS, PROJECTION SCREENS AND PROJECTOR BRACKETS.
D. PROVIDE BATT INSULATION IN ALL SOFFITS CONTAINING MECHANICALEQUIPMENT. AT SOFFITS AND ROOMS COMMUNICATING WITH EXTERIORLOCATIONS PROVIDE 2" RIGID INSULATION ADHERED TO THE UNDERSIDE OFSTRUCTURE AT ALL COMMUNICATING CEILINGS, FLOORS OR WALLS ASOCCURS.
E. BRACE ALL BULKHEADS AND SOFFITS TO THE STRUCTURE AT 4'-0" O.C. MIN.
EXISTING NON-RATED STUD WALL
EXISTING 1-HOUR FIRE-RATED STUD WALL
EXISTING TO REMAIN. PROTECT AND PRESERVE DURING THE COURSE OFCONSTRUCTION.
n
n
PLEASE RECYCLE
Key Plan
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:04:28 AM
CONSTRUCTION DOCUMENTS
A3.01
REFLECTED CEILING PLAN
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
1/8" = 1'-0"
1REFLECTED CEILING PLAN
NO. KEYNOTE
F
E
D
C
B
A
F
E
D
C
B
A
GRAPHIC LEGEND
CEILING NOTES
No. Description DateA ISSUED FOR CONSTRUCTION 10/5/12
E
C
B
A
765
D
R1
CPT
6
R1
CPT
6
CPT1 R1CPT1R1
CPT1R1
R1
CPT
CT4
R1
CT4
R1
CT1
R1
VCT1/3R1
VCT1/3R1
VCT1/3R1
VCT1/3R1
VCT1/3R1
R1VCT1/3
VCT1/3 R1
VCT1/3 R1
VCT1/3R1
VCT1/3R1
VCT1/3R1
CPT
1R
1
CPT
1R
1
VCT1/3 R1
VCT1/3 R1
VCT1/3 R1
VCT1/3 R1
VCT1/3 R1
PT-8PT-8PT-6APT-6A
PT-8
PT-6
PT-6
PT-6A
PT-6A
PT-6A
PT-6A
PT-7
PT-6
PT-7
PT-6APT-6A
PT-18
PT-18
PT-18
PT-18
PT-18
PT-18PT-18
PT-18PT-18
PT-18PT-18
PT-18
PT-18
PT-18
PT-18
PT-18
R5 R5
R8R8
R5
R5
CPT7, TYP.
R5
R5
OFFICE, PROV.SHARED
188
PROCED-PRIM
186
CHARTING A135B
EXAM-PRIM
222
EXAM-PRIM
193
EXAM-PRIM
223
EXAM-PRIM
225
EXAM-PRIM
224
EXAM-PRIM
191
EXAM-PRIM
195
EXAM-PRIM
220
CORRIDOR135
EXAM-PRIM
192
EXAM-PRIM
194
EXAM-PRIM
196
EXAM-PRIM
199
EXAM-PRIM
200
CORRIDOR190B
CHECKOUT
207
CHECKOUT
209
CHECK IN208
CORRIDOR159
ALCOVE,SCALE
216
POC198
COPY/PRINT/FAX
204
TLT-PATADA
203
TLT-PATADA
213
EXAM-PRIM
219
EXAM-PRIM
218
EXAM-PRIM
221
MA STATION-TYP.
197
CORRIDOR215A
MANAGEROFFICE
121
OFFICEREF.
211
TLT-STF, ADA217
CORRIDOR215B
CORRIDOR190A
CHARTING B190C
OFFICE, PROV.SHARED
187
PROCED-OB/GYN
185
1. REFER TO SPECIFICATION SECTION 09 06 00 FOR SCHEDULE OF FINISHES.2. ALL WALLS TO BE PT1 UNLESS NOTED OTHERWISE.3. REFER TO INTERIOR ELEVATIONS FOR WALL FINISHES AND HEIGHTS.
E
C
B
A
765
D
CGCGCG
CG CG CG
CG
CG
CG
CG
CG
CG
CG CG
CG CG
CGCG
CG
CG CG
CG
CG CG
CG
CG
CGCG
CG
CG
FRPFRPFRPFRP WP1 WP1
WP1
WP1
CGCG
CG CG
CG
WP-1WP-1
OFFICE, PROV.SHARED
188
OFFICE, PROV.SHARED
187
PROCED-PRIM
186
PROCED-OB/GYN
185
CORRIDOR135
CHARTING A135B
EXAM-PRIM
225
EXAM-PRIM
223
EXAM-PRIM
221
EXAM-PRIM
219
EXAM-PRIM
218
CORRIDOR159
MANAGEROFFICE
121
OFFICEREF.
211
CORRIDOR215B
CHECKOUT
209
CHECK IN208
CHECKOUT
207
CORRIDOR190B
COPY/PRINT/FAX
204
POC198
TLT-PATADA
213
TLT-PATADA
203
MA STATION-TYP.
197
EXAM-PRIM
200
EXAM-PRIM
199
EXAM-PRIM
196
EXAM-PRIM
194
CORRIDOR190A
EXAM-PRIM
195
EXAM-PRIM
220
EXAM-PRIM
222
EXAM-PRIM
224
EXAM-PRIM
193
EXAM-PRIM
191
CHARTING B190C
EXAM-PRIM
192
CORRIDOR215A
n
n
PLEASE RECYCLE
Key Plan
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:04:32 AM
CONSTRUCTION DOCUMENTS
A7.01
FLOOR FINISH,WALL ACCENT PAINT &WALL PROTECTION PLAN
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
F
E
D
C
B
A
F
E
D
C
B
A
1/8" = 1'-0"
1FLOOR PATTERN AND WALL ACCENT PAINT PLAN
No. Description Date
1/8" = 1'-0"
2WALL PROTECTION PLAN
1' - 0"1' - 0" 1' - 0"UNISEXMENWOMEN
ENTRANCE SIGNSDIRECTIONAL SIGNS
TOILET ROOM SIGNS
1/4" THICK ACRYLIC PLASTIC COLOR ANDCONTRAST SHALL BE DIFFERENT FROMCOLOR AND CONTRAST OF DOOR
SUBSURFACEIMAGESCENTERED ON SIGNTYP.
1/4" THICKACRYLIC PLASTIC
Toilet
3 3/
4"1"
1"1/
2"1"
n
PLEASE RECYCLE
Key Plan
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:04:34 AM
CONSTRUCTION DOCUMENTS
A8.01
ACCESSIBILITY NOTES
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
ACCESSIBILITY SIGNAGESANITARY FACILITIES (GENERAL)1. ON DOORWAYS LEADING TO MEN'S SANITARY FACILITIES, AN EQUILATERAL
TRIANGLE ¼ INCH THICK WITH EDGES 12 INCHES LONG AND A VERTEX POINTINGUPWARD SHALL BE PROVIDED AND ON DOORWAYS LEADING TO WOMEN'SSANITARY FACILITIES A CIRCLE ¼ INCH THICK AND 12 INCHES IN DIAMETERSHALL BE PROVIDED. UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED BY ACIRCLE 1/4 INCH THICK, 12 INCHES IN DIAMETER WITH A 1/4 THICK TRIANGLESUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12 INCH DIAMETER. THESEGEOMETRIC SYMBOLS SHALL BE CENTERED ON THE DOOR AT A HEIGHT OF 60INCHES AND THEIR COLOR AND CONTRAST SHALL BE DISTINCTLY DIFFERENTFROM THE COLOR AND CONTRAST OF THE DOOR.
LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN APATH OF TRAVEL, SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPEHARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWAREDESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASPTHE OPENING HARDWARE. LOCKED EXIT DOORS SHALL OPERATE AS ABOVE INEGRESS DIRECTION.1008.1.9.8.
THE FLOOR OR LANDING SHALL BE NOT MORE THAN 1/2 INCH LOWER THAN THETHRESHOLD OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4 INCH AND 1/2INCH SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2.
THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALLHAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENEDBY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUSCONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10INCH HIGH SMOOTHPANEL SHALL BE INSTALLED ON PUSH SIDE OF THE DOOR, WHICH WILL ALLOWTHE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING ATRAP OR HAZARDOUS CONDITION.
MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS FOR EXTERIORDOORS AND 5 LBS FOR INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEINGAPPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OFSLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOROPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIREDOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BEINCREASED TO THE MAXIMUM ALLOWABLE BY THE APPROPRIATEADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS.
THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE A MINIMUM OF 17 INCHESAND A MAXIMUM OF 19 INCHES MEASURED TO THE TOP OF THE TOILET SEAT.
PROVIDE 16-18 INCHES FROM THE CENTERLINE OF THE WATER CLOSETS TO THEADJACENT WALLS.
URINALS SHALL BE FLOOR MOUNTED, STALL-TYPE OR WALL HUNG. WHERE ONEOR MORE WALL-HUNG URINALS ARE PROVIDED, AT LEAST ONE WITH ANELONGATED RIM PROJECTING A MINIMUM OF 13.5 INCHES FROM THE WALL AND AMAXIMUM OF 17 INCHES FROM THE WALL AND A MAXIMUM OF 17 INCHES ABOVE THEFLOOR SHALL BE PROVIDED.
TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOTREQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. CONTROLS FORTHE FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS,NO MORE THAN 44 INCHES ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATECONTROLS SHALL BE NO GREATER THAN 5 POUNDS.
LAVATORIES, WHEN LOCATED ADJACENT TO A SIDE WALL OR PARTITION, SHALL BEA MINIMUM OF 18 INCHES TO THE CENTERLINE OF THE FIXTURE. ALL LAVATORIESTHAT ARE DESIGNATED TO BE ACCESSIBLE SHALL BE A MINIMUM 17 INCHES INHORIZONTAL DEPTH AND MOUNTED WITH THE RIM OR COUNTER EDGE NO HIGHERTHAN 34 INCHES ABOVE THE FINISHED FLOOR AND WITH VERTICAL CLEARANCEMEASURED FROM THE BOTTOM OF THE APRON OR THE OUTSIDE BOTTOM EDGE OFTHE LAVATORY OF 29 INCHES REDUCING TO 27 INCHES AT A POINT LOCATED 8INCHES BACK FROM THE FRONT EDGE. IN ADDITION, A MINIMUM 9 INCH HIGH TOECLEARANCE MUST BE PROVIDED EXTENDING BACK TOWARD THE WALL TO ADISTANCE NO MORE THAN 6 INCHES FROM THE BACK WALL. THE TOE CLEARANCESPACE MUST BE FREE OF EQUIPMENT OR OBSTRUCTIONS.
A CLEAR FLOOR SPACE 30 INCHES BY 48 INCHES COMPLYING WITH SECTION 305.3AND 306 SHALL BE PROVIDED IN FRONT OF A LAVATORY TO ALLOW FORWARDAPPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP ANACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 25 INCHES INTO KNEE ANDTOE SPACE UNDERNEATH THE LAVATORY.
HOT WATER AND DRAINPIPES ACCESSIBLE UNDER LAVATORIES SHALL BEINSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVESURFACES UNDER LAVATORIES.
FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONEHAND IN ACCORDANCE WITH THIS CHAPTER AND SHALL NOT REQUIRE TIGHTGRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TOACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBF. LEVER-OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS (PREFERABLE) AREEXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE ALLOWED IFTHE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS.
MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTINGSURFACE NO HIGHER THAN 40 INCHES FROM THE FLOOR.
WHERE TOWEL, SANITARY NAPKINS, WASTE RECEPTACLES, DISPENSERS, OTHEREQUIPMENT AND CONTROLS ARE PROVIDED, AT LEAST ONE OF EACH TYPE SHALLBE LOCATED ON AN ACCESSIBLE ROUTE, WITH ALL OPERABLE PARTS, INCLUDINGCOIN SLOTS, WITHIN 48 INCHES FROM THE FINISHED FLOOR SHALL COMPLY WITHSECTION
TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALL WITHIN 12INCHES OF THE FRONT EDGE OF THE TOILET SEAT, MOUNTED BELOW THEGRAB BAR, AT A MINIMUM HEIGHT OF 15 INCHES, AND 48 INCHES MAXIMUM TOTHE FAR EDGE FROM THE REAR WALL. DISPENSERS THAT CONTROL DELIVERYOR THAT DO NOT PERMIT CONTINUOUS PAPER FLOW SHALL NOT BE USED.
GRAB BARS, TUB AND SHOWER SEATS, FASTENERS AND MOUNTING DEVICESSHALL BE DESIGNED FOR A 250-LB. POINT LOAD.
THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALLBE 1-1/4 INCHES TO 2 INCHES OR THE SHAPE SHALL PROVIDE AN EQUIVALENTGRIPPING SURFACE. GRAB BARS SHALL NOT PROJECT MORE THAN 4.8" INTOANY REQUIRED CLEAR SPACES.
IF THE GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACEBETWEEN THE WALL AND THE GRAB BARS SHALL BE 1-1/2 INCHES. NO OBJECTTO BE LOCATED WITH IN 1-1/2" BELOW OR 12" ABOVE GRAB BARS.
A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT, SHALL BEFREE OF ANY SHARP OR ABRASIVE ELEMENTS.
EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8 INCH.
THE STRUCTURAL STRENGTH OF GRAB BARS, TUB AND SHOWER SEATS,FASTENERS, AND MOUNTING DEVICES SHALL MEET THE FOLLOWINGSPECIFICATIONS.
BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUMBENDING MOMENT FROM THE APPLICATION OF A 250-LB POINT LOAD SHALL BELESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAROR SEAT.
SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF A250-LB POINT LOAD SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESSFOR THE MATERIAL OF THE GRAB BAR OR SEAT, AND ITS MOUNTING BRACKETOR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECTAND TORSIONAL SHEAR STRESSES SHALL NOT EXCEED THE ALLOWABLESHEAR STRESS.
SHEAR FORCE INDUCED IN FASTENER OR MOUNTING DEVICE FROM THEAPPLICATION OF A 250-LB POINT LOAD SHALL BE LESS THAN THE ALLOWABLELATERAL LOAD OF EITHER THE FASTENER OR MOUNTING DEVICE OR THESUPPORTING STRUCTURE, WHICHEVER HAS THE SMALLER ALLOWABLE LOAD.
TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF A250-LB POINT LOAD, PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OFA 250-LB POINT LOAD, SHALL BE LESS THAN THE ALLOWABLE WITHDRAWALLOAD BETWEEN THE FASTENER AND SUPPORTING STRUCTURE.
GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
REFER TO SHEET A8.2 FOR TYPICAL MOUNTING HEIGHTS.
ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERESOR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATEDNO MORE THAN 48 INCHES MEASURE FROM THE TOP OF THE RECEPTACLEOUTLET BOX OR RECEPTACLE HOUSING NOR LESS THAN 15 INCHESMEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX ORRECEPTACLE HOUSING TO THE LEVEL OF THE FINISH FLOOR OR WORKINGPLATFORM.
THE HEIGHT OF THE MANUAL FIRE ALARM BOXES SHALL BE 42"-48" TO THEHIGHEST POINT OF ACTIVATING HANDLE.
THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARDUSED TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BYPHYSICALLY DISABLED PERSONS AS SET FORTH IN THESE BUILDINGSTANDARDS. THE SYMBOL SPECIFIED ABOVE SHALL CONSIST OF A WHITEFIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO.15090 IN FEDERAL STANDARD 595B.
EMERGENCY WARNING SYSTEMS SHALL ACTIVATE A MEANS OF WARNING THEHEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCYNOT EXCEEDING TWO FLASHES PER SECOND (2Hz) NOR BE LESS THAN ONEFLASH PER EVERY SECOND (1Hz) THROUGHOUT THE LISTED VOLTAGE RANGEOF THE APPLIANCE.
PERMANENT ROOM SIGNAGE: 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
WHEN RAISED CHARACTERS ARE REQUIRED OR WHEN PICTORIAL SYMBOLS(PICTOGRAMS) ARE USED ON SUCH SIGNS, THEY SHALL CONFORM TO THEFOLLOWING REQUIREMENTS:
CHARACTER TYPE: CHARACTERS ON SIGNS SHALL BE RAISED 1/32 INCHMINIMUM AND SHALL BE SANS SERIF UPPERCASE CHARACTERS ACCOMPANIEDBY GRADE 2 BRAILLE COMPLYING WITH CODE.
CHARACTER SIZE: RAISED CHARACTERS SHALL BE A MINIMUM OF 5/8 INCH ANDA MAXIMUM OF 2 INCHES HIGH.
PICTORIAL SYMBOL SIGNS (PICTOGRAMS): PICTORIAL SYMBOLS SIGNS(PICTOGRAMS) SHALL BE ACCOMPANIED BY THE VERBAL DESCRIPTIONPLACED DIRECTLY BELOW THE PICTOGRAM. THE OUTSIDE DIMENSION OF THEPICTOGRAM FIELD SHALL BE A MINIMUM OF 6 INCHES IN HEIGHT.
CHARACTER PLACEMENT: CHARACTERS AND BRAILLE SHALL BE IN AHORIZONTAL FORMAT. BRAILLE SHALL BE PLACED A MINIMUM OF 3/8 INCH AND AMAXIMUM OF 3/8 INCH DIRECTLY BELOW THE TACTILE CHARACTERS; FLUSHLEFT OR CENTERED. WHEN TACTILE TEXT IS MULTILINED, ALL BRAILLE SHALLBE PLACED TOGETHER BELOW ALL LINES OF TACTILE TEXT.
LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH TO HEIGHT RATIO OFBETWEEN 3:5 AND 1:1 AND A STROKE WIDTH-TO-HEIGHT RATIO BETWEEN 1:5AND 1:10.
CHARACTERS AND NUMBERS ON SIGNS SHALL HAVE A NON-GLARE FINISHAND CONTRAST WITH THEIR BACKGROUND, EITHER LIGHT CHARACTERS ON ADARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND.
CHARACTERS AND NUMBER ON SIGNS SHALL BE SIZED ACCORDING TO THEVIEWING DISTANCE FROM WHICH THEY ARE TO BE READ. THE MINIMUMHEIGHT IS MEASURED USING AN UPPER CASE X. LOWER CASE CHARACTERSARE PERMITTED. FOR SIGNS SUSPENDED OR PROJECTED ABOVE THEFINISHED FLOOR, THE MINIMUM CHARACTER HEIGHT SHALL BE 3".
CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLESYMBOLS ARE SPECIFICALLY REQUIRED IN OTHER PORTIONS OF THESEREGULATION. DOTS SHALL BE 1/10" ON CENTERS IN EACH CELL WITH 2/10"SPACE BETWEEN CELLS. DOTS SHALL BE RAISED A MINIMUM OF 1/40" ABOVETHE BACKGROUND.
TACTILE EXIT SIGNS COMPLYING WITH ICC A117.1 SHALL BE REQUIRED ATTHE FOLLOWING LOCATIONS:
1. EACH GRADE-LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BYA TACTILE EXIT WITH THE WORD, "EXIT."
2. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVELEXTERIOR EXIT BY MEANS OF A STAIRWAY OR RAMP SHALL BEIDENTIFIED BY A TACTILE EXIT SIGN WITH THE FOLLOWING WORDSAS APPROPRIATE:
A. "EXIT STAIR DOWN"B. "EXIT RAMP DOWN'C. "EXIT STAIR UP"D. "EXIT RAMP UP"
GENERAL. GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES ANDIN ACCESSIBLE ROOMS AND SPACES, INCLUDING FLOOR, WALKS, RAMPS,STAIRS, AND CURB RAMPS, SHALL BE STABLE, FIRM AND SLIP RESISTANT.
CHANGES IN LEVEL BETWEEN ¼ INCH AND ½ INCH SHALL BE MADE BY MEANSOF A RAMP NO STEEPER THAN 1 VERTICAL TO 2 HORIZONTAL.
CARPET: IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOORSURFACE, THAN IT SHALL BE SECURELY ATTACHED; HAVE A FIRM CUSHION,PAD OR BACKING OR NO CUSHION OR PAD; AND HAVE A LEVEL LOOP,TEXTURED LOOP, LEVEL-CUT PILE, OR LEVEL-CUT / UNCUT PILE TEXTURE.THE MAXIMUM PILE HEIGHT SHALL BE ½ INCH. EXPOSED EDGES OF CARPETSHALL BE FASTENED TO FLOOR SURFACES AND HAVE TRIM ALONG THEENTIRE LENGTH OF THE EXPOSED EDGE.
HAND-ACTIVATED DOOR OPENING HARDWARE, HANDLES, PULLS, LATCHES,LOCKS, AND OTHER OPERATING DEVICES ON ACCESSIBLE DOORS SHALLHAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOTREQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TOOPERATE. HARDWARE SHALL BE CENTERED BETWEEN 30 AND 44 INCHESABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND-ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITHA SINGLE EFFORT BY LEVER-TYPE HARDWARE, PANIC BARS, PUSH- PULLACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE.LOCKED EXIT DOORS SHALL OPERATE AS ABOVE IN EGRESS DIRECTION.
THE LAMP SHALL BE A XENON STROBE TYPE OR EQUIVALENT.
THE COLOR SHALL BE CLEAR OR NORMAL WHITE (I.E. UNFILTERED OR CLEARFILTER WHITE LIGHT.) AND SHALL NOT EXCEED 1000 CANDELA (EFFECTIVEINTENSITY).
THE MAXIMUM PULSE DURATION SHALL BE 0.2 SECOND WITH A MAXIMUM DUTYCYCLE OF 40 PERCENT. THE PULSE DURATION IS DEFINED AS THE TIME INTERVALBETWEEN INITIAL AND FINAL POINTS OF 10 PERCENT OF MAXIMUM SIGNAL.
THE FLASH RATE SHALL BE A MIN. OF 1 HZ AND A MAX. OF 2 HZ.
WALL MOUNTED APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE LENS ISNOT LESS THAN 80" (2.03 M) AND NOT GREATER THAN 96 IN. ABOVE THE FINISHFLOOR.
NOT USED.
CONTROLS AND OPERATING MECHANISMS IN ACCESSIBLE SPACES, ALONGACCESSIBLE ROUTES OR AS PARTS OF ACCESSIBLE ELEMENTS AND THOSEREQUIRED TO BE SHALL COMPLY WITH THE CODE.
CLEAR FLOOR SPACE SHALL ALLOW A FORWARD OR PARALLEL APPROACH BYA PERSON USING A WHEELCHAIR SHALL BE PROVIDED AT CONTROLS,DISPENSERS, RECEPTACLES, AND OTHER OPERABLE EQUIPMENT.
THE HIGHEST AND LOWEST OPERABLE PART OF ALL CONTROLS, DISPENSERS,RECEPTACLES, AND OTHER OPERABLE EQUIPMENT SHALL BE PLACED WITHIN48" OF THE FLOOR BUT NOT LOWER THAN 15" IF FORWARD APPROACHED ANDWITHIN 54" BUT NOT LOWER THAN 9" IF SIDE APPROACHED. ELECTRICAL ANDCOMMUNICATION SYSTEM RECEPTACLES ON WALLS SHALL BE MOUNTED NOLESS THAN 15" ABOVE THE FLOOR.
CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH THE ONEHAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OFTHE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NOGREATER THAN 5 POUNDS OF FORCE.
CONTROLS AND OPERATING MECHANISMS IN ACCESSIBLE SPACES, ALONGACCESSIBLE ROUTES OR AS PARTS OF ACCESSIBLE ELEMENTS AND THOSEREQUIRED TO BE ACCESSIBLE BY SHALL COMPLY WITH THE REQUIREMENTSOF SECTION 308.
CLEAR FLOOR SPACE COMPLYING WITH SECTION 305 THAT ALLOWS AFORWARD OR PARALLEL APPROACH BY A PERSON USING A WHEELCHAIRSHALL BE PROVIDED AT CONTROLS, DISPENSERS, RECEPTACLES, AND OTHEROPERABLE EQUIPMENT.
THE HIGHEST AND LOWEST OPERABLE PART OF ALL CONTROLS, DISPENSERS,RECEPTACLES, AND OTHER OPERABLE EQUIPMENT SHALL BE PLACED WITHIN48" OF THE FLOOR BUT NOT LOWER THAN 15" IF FORWARD APPROACHED ANDWITHIN 54" BUT NOT LOWER THAN 9" IF SIDE APPROACHED. ELECTRICAL ANDCOMMUNICATION SYSTEM RECEPTACLES ON WALLS SHALL BE MOUNTED NOLESS THAN 15" ABOVE THE FLOOR.
CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH THE ONEHAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OFTHE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NOGREATER THAN 5 POUNDS OF FORCE.
STROBE SIGNALING DEVICES REQUIRED FOR THE HEARING IMPAIRED SHALL BESTATE FIRE MARSHALL APPROVED AND LISTED.
TO ENSURE THAT AUDIBLE PUBLIC MODE SIGNALS ARE CLEARLY HEARD,UNLESS OTHERWISE PERMITTED BY CODE, THEY SHALL HAVE A SOUND LEVELAT LEAST 15 dB ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 dB ABOVETHE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS,WHICHEVER IS GREATER, MEASURED 1.5 M (5 FT) ABOVE THE FLOOR IN THEAREA REQUIRED TO BE SERVED BY THE SYSTEM USING THE A-WEIGHTEDSCALE (dBA).
TO ENSURE THAT AUDIBLE PRIVATE MODE SIGNALS ARE CLEARLY HEARD,THEY SHALL HAVE A SOUND LEVEL AT LEAST 10 dB ABOVE THE AVERAGEAMBIENT SOUND LEVEL OR 5 dB ABOVE THE MAXIMUM SOUND LEVEL HAVING ADURATION OF AT LEAST 60 SECONDS, WHICHEVER IS GREATER, MEASURED 1.5M (5 FT) ABOVE THE FLOOR IN THE AREA REQUIRED TO BE SERVED BY THESYSTEM USING THE A-WEIGHTED SCALE (dBA).
SPACING IN ROOMS:
MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED.EXCEPTION: WHERE A PAIR OF DOORS SERVES A STORAGE OR EQUIPMENTROOM, MANUALLY OPERATED EDGE- OR SURFACE-MOUNTED BOLTS AREPERMITTED ON THE INACTIVE LEAF.
IN GROUPS B, F, M AND S, HORIZONTAL SLIDING OR VERTICAL SECURITYGRILLES ARE PERMITTED AT THE MAIN EXIT AND SHALL BE OPENABLE FROM THEINSIDE WITHOUT THE USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORTDURING PERIODS WHEN THAT SPACE IS OCCUPIED. THE GRILLES SHALLREMAIN SECURED IN THE FULL-OPEN POSITION DURING THE PERIOD OFOCCUPANCY BY THE GENERAL PUBLIC. WHERE TWO OR MORE MEANS OFEGRESS ARE REQUIRED, NOT MORE THAN ONE-HALF OF THE EXITS OR EXITACCESS DOORWAYS SHALL BE EQUIPPED WITH HORIZONTAL SLIDING ORVERTICAL SECURITY GRILLES.
THE CLEAR WIDTH OF MEANS OF EGRESS COMPONENTS IN AREA SERVING BEDOR LITTER PATIENTS SHALL BE SUCH TO ALLOW READY PASSAGE OF BEDS,GURNEYS AND SIMILAR EQUIPMENTS, BUT SHALL NOT BE LESS THAN 44 INCHES.ENTRANCE DOORS TO PATIENTS' BEDROOMS FROM CORRIDORS SHALL NOTSWING INTO THE REQUIRED WIDTH OF CORRIDORS.
FOR HINGED DOOR, THE OPENING WIDTH SHALL BE MEASURED WITH THE DOORPOSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.NONETHELESS, EXIT DOOR SHALL SWING TO THE FULLY OPEN POSITION.DOORS WHEN FULLY OPENED, AND HANDRAILS SHALL NOT REDUCE THEREQUIRED WIDTH BY MORE THAN 7 INCHES. DOORS IN ANY POSITION SHALLNOT REDUCE THE REQUIRED WIDTH BY MORE THAN ONE HALF OF CORRIDORWIDTH.
WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE DOORS SHALLPROVIDE A CLEAR, UNOBSTRUCTED OPENING WIDTH OF 44" MIN. CLEAR WITHTHE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSEDPOSITION.
THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGSSHALL EXTEND 24" PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIORDOORS AND 18" PAST THE STRIKE EDGE FOR INTERIOR DOORS.
PROVIDE CLEAR SPACE OF 12" PAST STRIKE EDGE OF THE DOOR ON THEOPPOSITE SIDE TO WHICH THE DOOR SWINGS. IF THE DOOR IS EQUIPPED WITHBOTH A LATCH AND A CLOSER ON THE PUSH SIDE OF THE DOOR.
NOTETHESE ARE MINIMUM STANDARDS FOR THESE SIGNS. SIGNS ARE REQUIRED TO BEADHESIVE MOUNTED AND CENTERED ON RESTROOM DOOR.
ENTRANCES
TOILET ROOM FIXTURES AND ACCESSORIES
GRAB BAR
ADDITIONALREQUIREMENTS
SIGNS & IDENTIFICATION
DOORS
NOTIFICATION APPLIANCES FOR THE HEARING IMPAIRED
GROUND AND FLOOR SURFACES
STROBE LIGHTS
CONTROLS & OPERATING MECHANISMS
SPACE ALLOWANCE & REACH RANGES
65.
67.
68.
69.
70.
71.
72.
a. THE INSTALLATION OF VISIBLE NOTIFICATION APPLIANCES INCORRIDORS 6.1 M (20 FT) OR LESS IN WIDTH SHALL BE INACCORDANCE WITH CODE AND DEPENDING ON THE REQUIREMENTS.
b. SUBSECTION 7.5.4.4 SHALL APPLY TO CORRIDORS NOT EXCEEDING6.1 M (20 FT) IN WIDTH.
c. IN A CORRIDOR APPLICATION, VISIBLE APPLIANCES SHALL BE RATEDNOT LESS THAN 15 cd.
d. CORRIDORS GREATER THAN 6.1 M (20 FT) WIDE SHALL COMPLY WITHTHE SPACING REQUIREMENTS FOR ROOMS IN ACCORDANCE WITH7.5.4.3.
e. VISIBLE NOTIFICATION APPLIANCES SHALL BE LOCATED NOT MORETHAN 4.57 M (15 FT) FROM THE END OF THE CORRIDOR WITH ASEPARATION NOT GREATER THAN 30.4 M (100 FT) BETWEENAPPLIANCES.
f. IF THERE IS AN INTERRUPTION OF THE CONCENTRATED VIEWINGPATH, SUCH AS A FIRE DOOR, AN ELEVATION CHANGE, OR ANY OTHEROBSTRUCTION, THE AREA SHALL BE TREATED AS A SEPARATECORRIDOR.
g. IN CORRIDORS WHERE MORE THAN TWO VISIBLE NOTIFICATIONAPPLIANCES ARE IN ANY FIELD OF VIEW, THEY SHALL FLASH INSYNCHRONIZATION.
h. WALL-MOUNTED VISIBLE NOTIFICATION APPLIANCES IN CORRIDORSSHALL BE PERMITTED TO BE MOUNTED ON EITHER THE END WALL ORTHE SIDE WALL OF THE CORRIDOR IN ACCORDANCE WITH SPACINGREQUIREMENTS.
a. SPACING SHALLL BE IN ACCORDANCE WITH CODE.b. VISIBLE NOTIFICATION APPLIANCES SHALL BE INSTALLED IN
ACCORDANCE WITH CODE. USING ONE OF THE FOLLOWING: i.ASINGLE VISIBLE NOTIFICATION APPLIANCE. ii. TWO VISIBLENOTIFICATION APPLIANCES LOCATED ON OPPOSITE WALLS. iii.TWOGROUPS OF VISIBLE NOTIFICATION APPLIANCES, WHERE VISUALAPPLIANCES OF EACH GROUP ARE SYNCHRONIZED, IN THE SAMEROOM OR ADJACENT SPACE WITHIN THE FIELD OF VIEW. THISSHALL INCLUDE SYNCHRONIZATION OF STROBES OPERATED BYSEPARATE SYSTEMS. iv. MORE THAN TWO VISIBLE NOTIFICATIONAPPLIANCES OR GROUPS OF SYNCHRONIZED APPLIANCES IN THESAME ROOM OR ADJACENT SPACE WITHIN THE FIELD OF VIEWTHAT FLASH IN SYNCHRONIZATION.
c. ROOM SPACING IN ACCORDANCE WITH CODE FOR WALL-MOUNTED APPLIANCES SHALL BE BASED ON LOCATING THEVISIBLE NOTIFICATION APPLIANCE AT THE HALFWAY DISTANCE OFTHE WALL.
d. AND SQUARE ROOMS WITH APPLIANCES NOT CENTERED OR INNONSQUARE ROOMS, THE EFFECTIVE INTENSITY (CD) FROM ONEVISIBLE WALL-MOUNTED NOTIFICATION APPLIANCE SHALL BEDETERMINED BY MAXIMUM ROOM SIZE DIMENSIONS OBTAINEDEITHER BY MEASURING THE DISTANCE TO THE FARTHEST WALLOR BY DOUBLING THE DISTANCE TO THE FARTHEST ADJACENTWALL, WHICHEVER IS GREATER, AS REQUIRED BY CODE.
e. IF A ROOM CONFIGURATION IS NOT IN SQUARE, THE SQUAREROOM SIZE THAT ALLOWS THE ENTIRE ROOM TO BEENCOMPASSED OR ALLOWS THE ROOM TO BE SUBDIVIDED INTOMULTIPLE SQUARES SHALL BE USED.
f. IF CEILING HEIGHTS EXCEED 9.14 M (30 FT), CEILING-MOUNTEDVISIBLE NOTIFICATION APPLIANCES SHALL BE SUSPENDED AT ORBELOW 9.14 M (30 FT) OR WALL-MOUNTED VISIBLE NOTIFICATIONAPPLIANCE SHALL BE INSTALLED IN ACOORDANCE WITH CODE.
g. CEILING-MOUNTED VISIBLE NOTIFICATION APPLIANCE IS AT THECENTER OF THE ROOM. IF THE CEILING-MOUNTED VISIBLENOTIFICATION APPLIANCE IS NOT LOCATED AT THE CENTER OFTHE ROOM, THE EFFECTIVE INTENSITY (CD) SHALL BEDETERMINED BY DOUBLING THE DISTANCE FROM THE APPLIANCETO THE FARTHEST WALL TO OBTAIN THE MAXIMUM ROOM SIZE
SPACING IN CORRIDORS:
64.
63.
62.
61.
3.
44.
43.
b.
20.
18.
17.
16.
5.
4.
3.
2.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
21.
22.
23.
24.
25.
26.
27.
28.
29.
19.
30.
31.
32.
33.
34.
35.
36.
37.
38.
41.
42.
43.
a. ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BYPERSONS WITH DISABILITIES AND AT EVERY MAJOR JUNCTION ALONGOR LEADING TO AN ACCESSIBLE ROUTE OF TRAVEL SHALL BEIDENTIFIED WITH A SIGN DISPLAYING THE INTERNATIONAL SYMBOL OFACCESSIBILITY AND WITH ADDITIONAL DIRECTIONAL SIGNS, ASREQUIRED, TO BE VISIBLE TO PERSONS ALONG APPROACHINGPEDESTRIAN WAYS.
MOUNTING LOCATION AND HEIGHTS. WHERE PERMANENTIDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, RAISEDLETTERS SHALL BE ACCOMPANIED BY BRAILLE. SIGNS SHALL BEINSTALLED ON THE WALL ADJACENT TO THE LATCH OUTSIDE THEDOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE,INCLUDING AT DOUBLE LEAF FLOORS, SIGNS SHALL BE PLACED ONNEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. MOUNTINGHEIGHT SHALL BE 60 INCHES ABOVE THE FINISH FLOOR TO THECENTER LINE OF THE SIGN. MOUNTING LOCATION SHALL BEDETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3 INCHESOF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS ORSTANDING WITHIN THE SWING OF A DOOR.
EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVELEXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE OR AN EXITPASSAGEWAY SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITHTHE WORDS, "EXIT ROUTE."EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO ACORRIDOR OR HALLWAY THAT IS REQUIRED TO HAVE A VISUAL EXITSIGN SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THEWORDS, "EXIT ROUTE." EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BEIDENTIFIED BY A SIGN WITH THE WORDS, "TO EXIT."HEIGHT OF WORK SURFACES: THE TOPS OF TABLES AND COUNTERSSHALL BE 28 INCHES TO 34 INCHES FROM THE FLOOR OR GROUND.
WHERE A SINGLE COUNTER CONTAINS MORE THAN ONE TRANSACTION, SUCHAS (BUT NOT LIMITED TO) A BANK COUNTER WITH MULTIPLE TELLER WINDOWSOR A RENTAL SALES COUNTER WITH MULTIPLE CASH REGISTER STATIONS, ATLEAST 5 PERCENT, BUT NEVER LESS THAN ONE OF EACH TYPE OF STATION OFCOUNTER THAT IS AT LEAST 36 INCHES LONG AND NO MORE THAN 28 TO 34INCHES HIGH.
4.
5.
45.
46.
47.
48.
49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
66.
44.
No. Description Date
5' -
0"
4' -
6 3/
4"
4'-0
" MAX
HIG
H R
EAC
H
3'-0
" MIN
. FO
R C
ON
TRO
LS
1'-3
" MIN
. LO
W R
EAC
H
2' - 6"
5' -
0"
5' -
0"5' -
9"
REQ'D SIGNAGEAT MEN'S
TOILET ENTRYDOOR
REQ'D SIGNAGEAT WOMEN'S
TOILET ENTRYDOOR
REQ'D SIGNAGEAT MENS
TOILET ENTRYDOOR
CH (COAT HOOK)WALL- MOUNTED EXITSIGN AT EXIT DOOR
EXIT
EXIT SIGN ABOVE DOOR. REFERTO CEILING PLAN FOR LOCATION
WALL-MOUNTED TACTILE EXIT SIGN AT ALLEXIT DOORS TO COMPLY WITH ICC A117.1
3' -
6"
7' -
2"
7' -
2"
1'-3
" MIN
. LO
W R
EAC
H
LIGHT SWITCH& DIMMER
SECURITYSTROBE
LIGHT (BLUELIGHT)
AUDIBLE &VISUAL
FIRE ALARM
EMERGENCYSTROBE OR
LIGHT AND/ OR NURSE CALL
LIGHT
CARD READER, LOCAL ALARM, OR
ARMING STATIONTHERMOSTAT JUNCTION BOX SPECIAL
PURPOSEOUTLETS
DUPLEXOUTLETS
1' -
6"
MANUAL FIREALARM PULL
STATIONDUPLEX/ QUAD
OUTLETSDESK
INTERCOMOUTLET
U.O
.N.
2' -
6 1/
2"
WALL PROTECTION PER PLAN
1" M
IN. EQUIPMENT, PANEL
BOARD,CABINET, ORSIMILAR FEATURE
4'-0
" MAX
HIG
H R
EAC
H
3'-0
" MIN
. FO
R C
ON
TRO
LS
1'-3
" MIN
. LO
W R
EAC
H
4'-0
" MAX
HIG
H R
EAC
H
3'-0
" MIN
. FO
R C
ON
TRO
LS
5' -
0"
3'-4
" MAX
. AD
A
9"
6" MAX.
1'-5" MIN.2'
-10"
MAX
TO
RIM
3'-4
" MAX
2'-5
" MIN
. CLR
.
2'-3
" MIN
. CLR
.
INSULATEEXPOSEDPIPING,TYP. BOTTOM OF MIRROR REFLECTIVE
SURFACE
WALL F.O.F.
WALL-MOUNTED LAVATORY &MIRROR (SIDE VIEW)
NURSE CALL
TOILET PAPERDISPENSERTOILETRY WALLSHELF, WHEREOCCURSSEAT COVERDISPENSER
MAX
1' - 0" 3' - 6"
1' - 4"
MIN
.
1' -
7" 3'-4
" MAX
AD
A
3' -
10"
2'-0" MIN.
SEAT
AD
A
1'-5
" TO
P O
F
3'-0" MAX
MAX.
1' - 0"
1/2"
ALIGN
ADA
2' -
9"
3" MAX.
WALL F.O.F.
WALL F.O.F.
4' -
6"
ACCESSIBLE TOILET
BULLETIN BOARD
SEAT COVERDISPENSER
WALL F.O.F.1' - 0"
1' - 6"
8" 1' - 4"3'
- 8"
1' - 8"1' - 3" 1' - 5 1/2"
WALL MOUNTEDLAVATORY(SIDE VIEW)
WALL MOUNTEDLAVATORY WITHMIRROR
WALL MOUNTEDLAVATORY WITHMIRROR
WALL MOUNTEDLAVATORY
WALL MOUNTED SINK ACCESSORIES@ SINK CABINET
BAC
KSPL
ASH
2" A
BOVE
5" 10"
SEAT
AD
A
1'-5
" TO
P O
F
SEAT
AD
A
1'-5
" TO
P O
F
3' - 0"
SEAT
AD
A
1'-5
" TO
P O
F
3" B
ACKI
NG
TOILET TISSUEDISPENSER
2' -
5"
PAPER TOWELDISPENSER
FOR
CO
NTR
OLS
3'-2
" MAX
.
SOAPDISPENSER
EXIT6"
6"
5'-0
"
PLEASE RECYCLE
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:04:35 AM
CONSTRUCTION DOCUMENTS
A8.02
TYPICAL MOUNTING HEIGHTS ANDDIMENSIONING CONVENTIONS
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
NOTESA. IT IS THE INTENT OF THE DESIGN THAT ALL ITEMS SHOWN
MOUNTED AT TYPICAL HEIGHTS. BE ACCESSIBLE TOPERSONS WITH DISABILITIES.
B. THE PURPOSE OF THIS SHEET IS TO ILLUSTRATE TYPICALMOUNTING HEIGHTS AND- WHERE APPLICABLE - TYPICALMINIMUM OR MAXIMUM CLEARANCES &/OR TYPICALMOUNTING CONFIGURATIONS FOR A VARIETY OF ITEMS.CAUTION: THIS SHEET MAY ILLUSTRATE ITEMS ORCONFIGURATIONS WHICH DO NOT OCCUR AS PART OF THEWORK OF THIS PROJECT. REFER TO THE PLANS,ELEVATIONS, SECTIONS, DETAILS. AND SCHEDULES TODETERMINE WHICH ITEMS & CONFIGURATIONS APPLY TO THEWORK OF THIS PROJECT.
C. THE MOUNTING HEIGHTS CLEARANCES, ANDCONFIGURATIONS SHOWN ON THIS SHEET ARE TYPICAL ANDSHALL APPLY TO ALL INSTANCES OF THE ITEM (OR GROUPOF ITEMS) SHOWN UNLESS SPECIFICALLY NOTED ORDIMENSIONED OTHERWISE. TYPICAL DIMENSIONS SHOWNON THIS SHEET. TAKE PRECEDENCE OVER TYPICALDIMENSIONS SHOWN ON THE ELECTRICAL OR MECHANICALDRAWINGS FOR THE MOUNTING OF ITEMS INSTALLED BY THEELECTRICAL OR MECHANICAL TRADES.
D. SPECIAL OR NON-TYPICAL MOUNTING HEIGHTS OCCUR ONLYWHERE INDICATED BY ANNOTATED SYMBOLS; BY KEYNOTES; BY NOTES ON PLANS, ELEVATIONS, OR DETS.; OR BYUNIQUE DIMENSIONS ON ELEVATIONS OR DETAILS.
E. FOR ADDITIONAL INFORMATION REGARDING THEPRECEDENCE OF DRAWINGS FOR DETERMINING THE EXACTLOCATION OF EACH EXPOSED PART OF THE WORK, REFER TOTHE "ARCHITECTURAL GENERAL NOTES".
F. TYPICAL MOUNTING HEIGHTS FOR ADDITIONAL ITEMS NOTSHOWN ON THIS SHEET. MAY BE ILLUSTRATED BY OTHERSHEETS. REFER TO THE "INDEX OF DWGS." FOR ADDITIONALINFORMATION.
G. MOUNTING CONFIGURATION DIAGRAMS ARE ELEVATIONSWHICH ILLUSTRATE TYPICAL RULES GOVERNING THERELATIONSHIPS BETWEEN - AND PLACEMENT OF - ITEMSWHICH OCCUR IN GROUPS OF RELATED ITEMS (SUCH ASTOILET ACCESSORIES) OR IN CLOSE PROXIMITY TO OTHERPARTS OF THE WORK (SUCH AS SWITCHES AND DOORFRAMES). UNLESS OTHER MOUNTING CONFIGURATIONS ARESPECIFICALLY NOTED, DIMENSIONED, OR ELEVATED, THETYPICAL RELATIONSHIPS, ARRANGEMENTS, & DIMENSIONSSHOWN BY THE TYPICAL CONFIGURATION DIAGRAMS APPLYTHROUGHOUT THE WORK OF THIS PROJECT.
H. TYPICAL MOUNTING CONFIGURATIONS FOR ADDITIONALGROUPINGS NOT SHOWN ON THIS SHEET. MAY BE SHOWNON OTHER SHEETS. REFER TO THE "INDEX OF DWGS" FORADDITIONAL INFORMATION.
I. MOUNTING HEIGHTS, DIMENSIONS, CLEARANCES, & ACCESSREQUIREMENTS FOR TOILET ACCESSORIES SHOWN ON THISSHEET. ARE BASED UPON SPECIFIC MANUFACTURERS &MODELS AS INDICATED BY THE SPECIFICATIONS. WHENSIMILAR ACCESSORIES OF OTHER SPECIFIED, ACCEPTABLEMANUFACTURERS (IF ANY) ARE UTILIZED,MOUNTINGHEIGHTS, DIMENSIONS, CLEARANCES, & ACCESSREQUIREMENTS OF THE SIMILAR ACCESSORIES MAY VARYFROM THOSE SHOWN HERE. WHEN SIMILAR ACCESSORIESARE UTILIZED, THE CONTRACTOR SHALL BE RESPONSIBLEFOR ALL COORDINATION REQUIRED TO ACHIEVE THE SAMEAESTHETIC AND FUNCTIONAL DESIGN INTENT ILLUSTRATEDBY THE CONFIGURATION SHOWN ON THE DRAWINGS.
J. REFER TO SIGNAGE DRAWINGS SG SHEETS FOR TYPES,LOCATIONS AND MOUNTING HEIGHTS.
? 1/2" = 1'-0"
TYPICAL MOUNTING HEIGHTS
No. Description Date
COMPUTR
PHONE01
RB-1
SS-1 SS-1
1' -
0"2'
- 2"
COMPUTR
PHONE01
COMPUTR
SS-1 SS-1RB-1
4"
WEBCAM
COMPUTR
PHONE01RB-1
U
36 33 24
CDS222
U
36 30 12
CDS302
SS-1
WC02WC02
WP-1
RB-1
COMPUTR
2' -
6"1'
- 0"
COMPUTR
PL-2
SS-1
RB-1
COMPUTR
PHONE01
PL-2
PL-2
SS-1
PHONE01COMPUTR
10.15 OPEN
RB-1
PL-2
SS-1
RB-1
PL-2
SS-1
2' -
6"
1' -
6"
4' -
0"
1' -
6"
COMPUTR
WEBCAM
PHONE01
COMPUTRCOMPUTR
PHONE01WEBCAM
PHONE01
COMPUTR
WEBCAM
2' -
6"1'
- 0"
PT-7
PL-2
OPEN
PL-2PL-2
1' -
6"
NAPDSPLTLTPPR
CT-5
CT-6
PT-8
PPRTWL
TLTPPRNAPDSPL
10.13
CT-5
CT-6
PT-8 CT-5
10.12
161
PPRTWL
SOAP
CT-5
CT-6
PT-8
TLTSTCVR
CT-5
CT-6
PT-8
CT-5
4'-0
"
SANITZR
U
36 33 19
CDS222U
18 33 19
CDS254
WP-1
PL-1SS-1
RB-1
SCALE01
PHYSMON
RB-1
WP-1
SCALE01PHYSMON
WP-1
RB-1
PL-1
SS-1
PLEASE RECYCLE
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:04:38 AM
CONSTRUCTION DOCUMENTS
A8.03
INTERIOR ELEVATIONS
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
No. Description Date
NO. KEYNOTE
10.12 ADA COMPLIANT GRAB BAR10.13 WALL-MOUNT MIRROR - TILE BEHIND MIRROR IN ALL
LOCATIONS10.15 ARTWORK BY OWNER
7B 7A
5B 5A
3A
6B 6A
4B 4A
2D 2C 2B 2A
1C 1B 1A
COPY/ PRINT FAX 170 - D, 204 - B 51/4" = 1'-0"
ALCOVE SCALE 158 - D, 216 - B 11/4" = 1'-0"
WHEEL CHAIR ALCOVE 160 - A, 214 - A 31/4" = 1'-0"
TLT-PAT ADA 203-D, 213 - B 21/4" = 1'-0"
CHECK IN, 166-C, 208 - C 41/4" = 1'-0"
CHECK OUT, 165-D, 209 -B 61/4" = 1'-0"
CHECK OUT, 167-D, 207 -B 71/4" = 1'-0"
OPHTHOTO
SPHYG
2' -
0" 4' -
0"
1'-0"
1'-0
"4'
-0"
6"
COATHOOKS
147OPHTHOTO
SPHYG
PL-1
SS-1
RB-1 2' -
0"
U
24 20 12
CDS301U
24 20 12
CDS301
SHARPS
SOAPPPRTWL
SS-1
PL-1RB-1
4' -
0"
2' -
0"
6" DIA. OPENING IN COUNTERTOP TOWASTE BELOW. COORDINATELOCATION AND SIZE WITH OWNERPRIOR TO INSTALLING
(3) GLOVE-DISPENSING OPENINGSTHROUGH DOOR. COORDINATE
LOCATION AND SIZE WITH OWNERPRIOR TO INSTALLING.
2'-1
0"1'
-11"
1'-8
"2'
-7"
9'-0
"
SHARPS
PPRTWL
10.15PL-1
SS-1
PL-1
RB-1
5' -
0"
1' - 0" 1'-0" x 1'-0"MIRROR
LAPTOPPHONE01
LAPTOPPHONE01
1' -
6"
2' -
0"
2' -
0"
LAPTOP
PHONE01
LAPTOP
DEFIBCABLAPTOPLAPTOP
PHONE01
LAPTOP
PHONE01
LAPTOP
PHONE01
1' -
6"
1' -
6"
4' -
0"
LAPTOPPHONE01
LAPTOP
PHONE01
REFRIG02
PL-1
SS-1
PL-1
RB-1
WHTBRD09
U
33 33 24
CDS222 U
33 33 24
CDS222
REFRIG03
REFRIG02
SS-1
PL-1
RB-1
4' -
0"
2' -
0"
2' -
0"
GLVBOX
SHARPS
SOAP
PPRTWL
REFRIG03
SS-1
PL-1
SS-1
RB-1 RB-1
4' -
0"
U
33 33 12
CDS302 U
33 33 12
CDS302
U
39 33 24
CDS222
COMPUTRPPRTWL
SOAP
SHARPS
GLVBOX
PASS-THRU PL-1
SS-1
PL-1RB-1
PL-1
1' -
6"4' -
0"
6" DIA. OPENING IN COUNTERTOPTO WASTE BELOW. COORDINATE
LOCATION AND SIZE WITH OWNERPRIOR TO INSTALLING
U
16 33 24
CDS254
10.12
TLTPPR
10.13
CT-5
CT-6
PT-8CT-6
CT-5
CT-6
PT-8
SOAP157 10.12
CT-5
CT-6
PT-8
TLTSTCVR
TLTPPR
10.12
NAPDSPLCT-5
CT-6
PT-8
PLEASE RECYCLE
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:04:41 AM
CONSTRUCTION DOCUMENTS
A8.04
INTERIOR ELEVATIONS
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
2-A 2-B 2-C 2-D
3-A 3-B 3-C 3-D
EXAM-PRIM 147, (TYP.) 21/4" = 1'-0"
M. A. TYP 154, 197 (MIRROR) 31/4" = 1'-0"
POC 155, 198 (MIRROR) 11/4" = 1'-0"
1-A 1-B 1-C 1-D
4-A 4-B 4-C 4-D
TLT-STF 157, 217 (MIRROR) 41/4" = 1'-0"
No. Description DateA ISSUED FOR CONSTRUCTION 10/5/12
NO. KEYNOTE
10.12 ADA COMPLIANT GRAB BAR10.13 WALL-MOUNT MIRROR - TILE BEHIND MIRROR IN ALL
LOCATIONS10.15 ARTWORK BY OWNER
CLOCK
LAPTOP
PHONE01
LAPTOP
PHONE01
B B
RB-1
PHONE01
LAPTOPLAPTOP
PHONE01
RB-1
PHONE01
LAPTOP
141
RB-1
PHONE01
LAPTOP
RB-1 RB-1
U
16 33 24
CDS254 U
24 33 24
CDS222
U
30 30 12
CDS302 U
30 30 12
CDS302
PPRTWL
SOAP
SHARPS
PL-1
SS-1
PL-1
4' -
0"
6" DIA. OPENING IN COUNTERTOPTO WASTE BELOW. COORDINATE
LOCATION AND SIZE WITH OWNERPRIOR TO INSTALLING
FINISHEDEND PANEL
PL-1
PL-1
SS-1
4' -
0"
2' -
0"
143SHARPS
RB-12' -
0"
SOAP
PPRTWL
10.15 PL-1
SS-1PL-1
RB-1 2' -
0"4' -
0"
PLEASE RECYCLE
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:04:43 AM
CONSTRUCTION DOCUMENTS
A8.05
INTERIOR ELEVATIONS & ROOMFINISH SCHEDULE
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
3-A 3-B 3-C 3-D 3-D1
4-A 4-B 4-C 4-D
OFFICE 141, 142 (MIRROR), 187, 188 (MIRROR) 31/4" = 1'-0"
PROCED-PRIM 143, 144 (MIRROR), 185, 186 (MIRROR) 41/4" = 1'-0"
No. Description Date
NO. KEYNOTE
10.15 ARTWORK BY OWNER26.03 POWER - SEE ELECTRICAL
ROOM FINISH SCHEDULE
NUMBER NAME
FLOOR BASE WAINSCOT WALLS
CEILINGMATERIAL REMARKSM
ATER
IAL
MAT
ERIA
L
MAT
ERIA
L
HEI
GH
T
NORTH EAST SOUTH WEST
MAT
ERIA
L
FIN
ISH
MAT
ERIA
L
FIN
ISH
MAT
ERIA
L
FIN
ISH
MAT
ERIA
L
FIN
ISH
ALCOVE, SCALE216 ALCOVE, SCALE R1 RB-1 WP-1 PT-1 EG PT-1 EG PT-1 EG ACT-2
CHARTING A135B CHARTING A R1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-2
CHARTING B190C CHARTING B R1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-2
CHECK OUT207 CHECK OUT CPT1 RB-1 PT-6 EG PT-1 EG PT-1 EG ACT-10209 CHECK OUT CPT1 RB-1 PT-1 EG PT-6 EG PT-1 EG ACT-10
CHECK IN208 CHECK IN CPT1 RB-1 PT-6 EG PT-1 EG ACT-10
COPY/ PRINT/FAX204 COPY/ PRINT/FAX CPT1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-1 EG ACT-10
CORRIDOR135 CORRIDOR R1 RB-1 PT-1 EG PT-7/PT-1 EG PT-1 EG PT-1 EG ACT-2159 CORRIDOR R1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-6A/
PT-1EG ACT-2
190A CORRIDOR R1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-1 EG ACT-2190B CORRIDOR R1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-1 EG ACT-2215A CORRIDOR R1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-1 EG ACT-2215B CORRIDOR R1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-1 EG ACT-2
EXAM- PRIM191 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-18 EX PT-1 EG PT-1 EG ACT-1192 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-18 EX ACT-1193 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-18 EX ACT-1194 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-18 EX PT-1 EG PT-1 EG ACT-1195 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-18 EX ACT-1196 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-18 EX ACT-1199 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-18 EX PT-1 EG PT-1 EG ACT-1200 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-18 EX ACT-1218 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-18 EX PT-1 EG PT-1 EG ACT-1219 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-18 EX PT-1 EG PT-1 EG ACT-1220 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-18 EX ACT-1221 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-18 EX PT-1 EG PT-1 EG ACT-1222 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-18 EX ACT-1223 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-18 EX ACT-1224 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-18 EX PT-1 EG PT-1 EG ACT-1225 EXAM- PRIM VCT1 RB-1 PT-1 EG PT-18 EX PT-1 EG PT-1 EG ACT-1
MA STATION- TYP.197 MA STATION- TYP. R1 RB-1 PT-1 EG PT-6A/PT-1 EG PT-1 EG PT-6 EG ACT-3/ PT-1
MANAGER OFFICE121 MANAGER OFFICE CPT RB-1 PT-1 EG PT-1 EG PT-1 EG PT-18 EG ACT-1
OFFICE REF.211 OFFICE REF. CPT1 RB-1 PT-1 EG PT-7 EG PT-1 EG PT-1 EG ACT-1
OFFICE, PROV. SHARED187 OFFICE, PROV. SHARED CPT1 RB-1 PT-8 EG PT-1 EG PT-1 EG PT-1 EG ACT-1188 OFFICE, PROV. SHARED
POC198 POC R1 RB-1 PT-1 EG PT-1 EG PT-1 EG PT-1 EG ACT-2
PROCED- OB/GYN185 PROCED- OB/GYN VCT1 RB-1 PT-1 EG PT-1 EG PT-6A EG PT-1 EG ACT-1
PROCED- PRIM186 PROCED- PRIM VCT1 RB-1 PT-1 EG PT-1 EG PT-6A EG PT-1 EG ACT-1
TLT-PAT ADA203 TLT-PAT ADA CT4 CT5 CT5/CT6 4' - 0" PT-8 SG PT-8 SG PT-8 SG PT-8 SG PT-2
TLT-PAT ADA213 TLT-PAT ADA CT4 CT5 CT5/CT6 4' - 0" PT-8 SG PT-8 SG PT-8 SG PT-8 SG PT-2
TLT-STF, ADA217 TLT-STF, ADA CT1 CT5 CT5/CT6 4' - 0" PT-8 SG PT-8 SG PT-8 SG PT-8 SG PT-2
ROOM FINISH SCHEDULE 1NONE
1. REFER TO CABINET TAG ON INTERIOR ELEVATIONS FOR DIMENSIONS
W H D
### M# D- CABINET WIDTHH- CABINET HEIGHTW- CABINET WIDTH
MFR. REFERENCE NUMBERMODIFICATION NUMBER
CABINIET BEYOND
CORIAN COUNTERTOP
WASTE RECEPTACLE
CABINET PULL
METAL STUD WALL ASSEMBLY. REFERTO FLOOR PLAN FOR WALL TYPE.
BACKING PER DETAIL
FLOOR BASE- REFER TO ROOM FINISHSCHEDULE
2' - 1"
1"
1 1/
2"
3
A10.02
CABINET OPENING
5"7"
2' -
10"
METAL STUD WALL ASSEMBLY REFER TO FLOOR PLAN FOR WALL TYPE
BACKING PER DETAIL
WALL CLEAT PER DETAIL
SINK, SEE PLUMBING DRAWINGS
NO DRIP BULLNOSE AT ALL SINKMODULES U.O.N.
CABIINET PULL TYP.MILL WORKER TO COORDINATE CUTOUT FOR ELECTRICAL ACCESS
REMOVABLE ACCESS PANEL
ANCHORAGE, TYPICALMODULAR BASE CABINET
1 1/
2"
2'-0" U.O.N.
2'-1" U.O.N.
8
A10.01
3
A10.02
ATTACH TO BACKING W/ #10 FLAT HEADS.M.S. SPACING PER
BACKING PLATE PER
GYPSUM BOARD PER SCHEDULEWALL TYPE. SEE PLAN.
3/4" THICK WOOD CLEAT
ATTACH TO WALL CLEAT W/ (3) #10 PANHEAD S.M.S.
34" A
.F.F
. MAX
.
CAB
INET
HEI
GH
T
METAL STUD WALL ASSEMBLY REFER TO FLOOR PLAN FOR WALL TYPE
BACKING PER DETAIL
WALL CLEAT PER DETAIL
DRAWER W/ HEAVY BALLBEARING SLIDE, TYP.
CABIINET PULL TYP.
DOOR WHERE OCCURS
ADJUSTABLE SHELF
MODULAR BASE CABINET
ANCHORAGE TYPICAL
CABINET DEPTH
5"
1" U.O.N
8
A10.01
11
A10.01
3
A10.02
2' -
9 1/
2"
METAL STUD WALL ASSEMBLY REFER TO FLOOR PLAN FOR WALL TYPE
BACKING PER DETAIL
DIVIDER @ SINKS, WHERE OCCURS
SINK, SEE PLUMBING DRAWINGS
NO DRIP BULLNOSE AT ALL SINKMODULES U.O.N.
WALL CLEAT PER DETAIL
INSULATION @ DRAIN PIPE
REFER TO STRUCTURAL FORANCHORAGE
1 1/
2"
2'-1" U.O.N.
2'-3
" MIN
. CLR
.
34" A
.F.F
. U.O
.N.
8
A10.01
3
A10.02
STRUCTURE ABOVE
WHERE FINISH IS NOT INSTALLED ONBOTH SIDES OF THE WALL PROVIDELATERAL BRACING
METAL STUD WALL ASSEMBLY. REFER TOFLOOR PLAN FOR WALL TYPE
WALL CLEAT PER DETAIL
BACKING PER DETAIL
CABINET DOOR & PULL WHEREOCCURS, TYP.
ADJUSTABLE SHELVING, TYP.
MODULAR WALL CABINET
LIGHT SOFFIT WHERE OCCURS VERIFYW/ UNDER CABINET LIGHT FIXTURESEE ELECT. DRAWINGS AND DETAIL
CAB
INET
HEI
GH
T
7'-0
" U.O
.N.
U.O.N.
1' - 2"
U.O.N.
1' - 3"
8
A10.01
12
A10.01
9
A10.01
HEI
GH
T VA
RIE
S
ALIG
N
MODULAR WALL CABINET
CEILING AS SCHEDULED- REFER TOCEILING PLAN AND ROOM FINISHSCHEDULE
PLASTIC LAMINATE SOFFIT- SECURETO CASEWORK W/ #10 x1 1/2"COUNTERSUNK WOOD SCREWS,2 @ S.B.I. RECOMMENDED SPACING O.C.
3/4"
2"
CABINET DOOR AS OCCURS
BOTTOM OF CABINET
TASK LIGHT, SEE MECHANICAL
34" A
.F.F
. MAX
.
CAB
INET
HEI
GH
T
METAL STUD WALL ASSEMBLY REFER TO FLOOR PLAN FOR WALL TYPE
BACKING PER DETAIL
WALL CLEAT PER DETAIL
NO DRIP BULLNOSE AT ALL SINKMODULES U.O.N.
CABIINET PULL WHERE OCCURS
DOOR WHERE OCCURS
ADJUSTABLE SHELF
MODULAR BASE CABINET
ANCHORAGE TYPICAL
CABINET DEPTH
1" U.O.N
8
A10.01
11
A10.01
3
A10.02
BASE CABINETS
UPPER CABINETS
CABINET 102WITH 1 ADJUSTABLE SHELVING
CABINET 222WITH 1 ADJUSTABLE SHELVING
CABINET 254WITH 4 DRAWERS
CABINET 230WITH 3 DRAWERS
CABINET 302WITH 1 ADJUSTABLE SHELVING
CABINET WIDTH
CABINET WIDTH CABINET WIDTH CABINET WIDTH
WALL PER FLOOR PLAN, WHERE OCCURS
BACKING PLATE, SEE
AT ISLAND, WHERE OCCURS
CABINETWD. SLEEPER, SEE
CABINET
CONCRETE SLAB ON GRADE
WALL BASE AND FINISH FLOORMATERIAL REFER TO ROOM FINISHSCHEDULE
(3) #8 F.H.W.S SCREW, PRE-DRILLED
1x4 CONT. WD. BASE
1- #10 F.H.W.S. WITH FINISH WASHER@ 10" O.C.
2x4x1'-0" WD. SLEEPER W/ (2) 3/8"EXPANSION ANCHOR. 2" MIN. EMBED
3"
DETAILSCALE: 1 1/2"= 1'-0"A
PLAN N.T.S.B
6" TYP.
6"-
3'-0" MAX. 6"-
CORIAN COUNTERTOP
WASTE RECEPTACLE
CABINET PULL
METAL STUD WALL ASSEMBLY. REFERTO FLOOR PLAN FOR WALL TYPE.
1 1/
2"
1' - 6" 1"
5"6"8"
1' - 4 1/4"
1"
n
PLEASE RECYCLE
Key Plan
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:04:46 AM
CONSTRUCTION DOCUMENTS
A10.01
MILLWORK DETAILS
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
3/4" = 1'-0"
6SECTION- WASTE RECEPTACLE CABINET
3/4" = 1'-0"
5SECTION AT SINK BASE CABINET
6" = 1'-0"
8SECTION AT CASEWORK WALL CLEAT
3/4" = 1'-0"
2SECTION AT CASEWORK BASE
3/4" = 1'-0"
4SECTION AT SINK BASE CABINET
3/4" = 1'-0"
7SECTION AT CASEWORK UPPER
3" = 1'-0"
9SECTION AT CASEWORK SOFFIT
6" = 1'-0"
12UNDER CABINET LIGHT SOFFIT
3/4" = 1'-0"
1SECTION AT CASEWORK BASE
? 1/2" = 1'-0"
CASEWORK TYPES
1 1/2" =1'-0"
11BASE CABINET ANCHORAGE
No. Description DateA ISSUED FOR CONSTRUCTION 10/5/12
3/4" = 1'-0"
10SECTION- EXAM WASTE RECEPTACLE CABINET
4 1/
4"1'
-8 5
/8"
1'-1
0 5/
8"7
7/8"
PROVIDE MANUFACTURERHORIZONTAL BRACE WHEREUPPER BIN OCCURS
UPPER BIN/ SHELF
STEEL STUD WALL ASSEMBLY, PERPLAN
BACKING PLATE, TYP.
FREESTANDING WORKSTATION (O.F.V.I)
CENTERLINE OF BACKING PLATE+8.25" A.F.F.
(2) SLOTTED STEEL CHANNELS PERBIN/ SHELF UNIT. FASTNERLOCATIONS PER MANUFACTURERMAX. LOAD OF 150 LBS. PER UNIT
NOTE:BACKING LOCATION SHALL BE VERIFIED BYCONTRACTOR PRIOR TO INSTALLATION
NOTE:1. CONTRACTOR TO VERIFY THE
LOCATION OF BACKING WITH CABINIETMANUFACTURER
2. FOR ADDITIONAL BACKINGINFORMATION AT FULL HEIGHTCABINETS, SEE FULL HEIGHT CABINETDETAIL
3. LOCATE S.M.S. MAX. 4" FROM END OFEACH CABINET
4. PROVIDE MINIMUM 2 S.M.S. PERBACKING PLATE TYP.
TOP OF UPPER/ FULL HEIGHT CABINET
METAL STUDS
BOTTOM OF UPPER CABINET
TOP OF BASE CABINETCOUNTERTOP
BOTTOM OF BASE/ FULL HEIGHTRCABINET
BACKING TYP.
NO. 12x2" SELF TAPPING S.M.S. TYP.
TYP
. U.O
.N.
3"TY
P. U
.O.N
.3"
4"12" MAX.
8" MIN. TYP. U.O.N.
8" 8" 8" 8"
16"-
16"- 1
A10.02
2'-0
" MAX
.
3"3"
3"
1'- 3" MAX.
2'-0" MAX.
3'-0
" MA
X. *
OVERHEAD CABINETWHERE OCCURS
BASE CABINETWHERE OCCURS
BASE ANCHORAGE
FLOOR
WALL FINISH TYP.
BACKING,TYP.
7-'6
" MAX
.
BACKING,TYP.
WALL STUDPER SCHEDULE
TYP. BRIDGING@ MIDSPAN IF GYP.NOT PRESENT PER
BACKING,TYP.
BACKING,TYP.
WALL STUDPER SCHEDULE
BASEANCHORAGE1'
-0" M
AX.
FLOOR
1'-0
" MAX
.
TYP. BRIDGING@ MIDSPAN IF GYP.NOT PRESENT PER
FULL HEIGHT CABINETS OVERHEAD AND/ OR BASE CABINETSB A
NOTES:1. THIS DETAIL SHOWS PARTITIONS SUPPORTING
FULL HEIGHT, OVERHEAD AND/ OR BASECABINETS ON ONE SIDE OF THE WALL. WHERECABINETS OCCUR ON BITH SIDES OF THEWALL, PROVIDE SPECIFIED BACKING ON BOTHSIDES OF THE WALL.
2. CABINETS SHALL BE ANCHORED TO BACKINGWITH NO. 12 x2" SELF TAPPING S.M.S. @ 16"O.C. MAX.
3. WALL STUDS MUST BE 16" O.C. MAX.4. CABINETS TYPE X MAY ONLY OCCUR ON ONE
SIDE OF THE WALL. THE WALL MAY ONLYHAVE A MINIMUM OF 6'-0" TRIBUTARY CEILINGPER
* - ANCHOR CABINET WITH HEIGHT. 36" PER B
CEILING LINE CEILING LINE
2' - 0"
FIRST FLOOR0"
2' -
6"
RUBBER BASE RB1
1' -
11 1
/2"
10"
8"
2' -
3 1/
4"
R 3"
4" STAINLESS STEEL BASELOW WALL PER PARTITION TYPES
BLOCKING, TYP
PLYWOOD SUBSTRATE WITHPLASTIC LAMINATE FINISH PL-2,
VERTICAL PATTERN
CPU HOLDER MOUNTED UNDER COUNTER
3/4" STIFFENER PLATE WELDED TOSTUD WITH BLOCKING BEHIND
ELECTRICAL OUTLET
THREADED ROD POINTSUPPORT WITH 1" CAP
CABLE TRAY
1" SQ. TUBE STEEL @ 16" O.C.
3" DIAM. GROMMET, FIELD VERIFY LOCATION(S)
SOLID SURFACE COUNTER SS-1, U.N.O.,BULLNOSE CORNER WITH EASED EDGE
(3) 1/2" BRUSHED STAINLESS TUBE STEELREINFORCEMENT WELDED TO TUBE STEEL
COUNTER SUPPORT TO SUPPORT MIN. 40 LBS.
1/2" RESIN PANEL WITH VERTICAL PATTERN
2"2"
2"
3' -
2"
24" CLEAR KNEE SPACE
3
VCT 3
VCT1
4
VCT1
VCT4
VCT5
VCT2 ACCENT
VCT12' - 0"
1' -
0"
2' - 0"
PLEASE RECYCLE
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:04:50 AM
CONSTRUCTION DOCUMENTS
A10.02
MILLWORK DETAILS
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
1 1/2" =1'-0"
2BACKING AT UPPER BIN/ SHELF UNIT
No. Description Date
3/4" = 1'-0"
3BACKING AT CASEWORK
1" = 1'-0"
1TYPICAL CABINET ANCHORAGE TO STUD WALLS
1 1/2" =1'-0"
5CHECK-IN/ CHECK-OUT DESK SECTION 1/2" = 1'-0"
7EXAM ROOM VCT PAT.
1/2" = 1'-0"
4PEDS ROOM VCT PATTERN
1/2" = 1'-0"
6VCT1 / VCT2 PATTERN
TERRAZZO FLOORING, SEEFINISH PLAN
1/8" HEAVY TOP ALUMINUMDIVIDER STRIP
CONSTRUCTION ADHESIVE
ANTI-FRACTURE MEMBRANEASREQUIRED
CONSTRUCTION OR SAW-CUTJOINT WHERE OCCURS, PERSTRUCTURAL DRAWINGS
CONCRETE FLOOR SLAB
TERRAZZO FLOORING, SEEFINISH PLAN
1/8" HEAVY TOPALUMINUM EDGE STRIP
1/2" TERRAZZO BASE
5/8" GYPSUM BOARD SUBSTRATE
CONTINUOUS BACKER ROD &CAULKING. INSTALL FIRE OR SMOKECAULKING AS REQUIRED BYPARTITION TYPE
1/4" ALUMINUM PERIMETER STRIP
ANTI-FRACTURE MEMBRANEASREQUIRED
CONCRETE FLOOR SLAB
CONSTRUCTION ADHESIVE
TERRAZZO FLOORING, SEEFINISH PLAN
1/4" ALUMINUM EDGE STRIP
CONSTRUCTION ADHESIVE
ANTI-FRACTURE MEMBRANEASREQUIRED
CONCRETE FLOOR SLAB
CAULKING AS REQUIRED
FLOOR LEVELING MATERIAL
ADJACENT FLOOR FINISH PERFINISH PLANS
212
TERRAZZO FLOORING, SEEFINISH PLAN
ANTI-FRACTURE MEMBRANE ASREQUIRED
CONCRETE FLOOR SLAB
1/8" ALUMINUM EDGE STRIP
CARPETDOOR AS SCHEDULED
CL OF DOOR
TERRAZZO FLOORING, SEEFINISH PLAN
1/4" ALUMINUM EDGE STRIP
CONSTRUCTION ADHESIVE
ANTI-FRACTURE MEMBRANEASREQUIRED
CONCRETE FLOOR SLAB
CAULKING AS REQUIRED
STOREFRONT SYSTEM
BACKER ROD
CERAMIC TILE
CONCRETE FLOOR SLAB,DEPRESSED SLAB WHEREOCCURS
QUARTZ STONE THRESHOLD
RESILIENT FLOORING
DOOR AS SCHEDULED
4"
1/4"
CARPET AS SCHEDULED
CONCRETE FLOOR SLAB,DEPRESSED SLAB WHEREOCCURS
REDUCING TRANSITION STRIP
RESILIENT FLOORING
DOOR AS SCHEDULED
L OF DOORC
OTHER RESILIENT FLOORINGPER FINISH SCHEDULE
CONCRETE FLOOR SLAB,DEPRESSED SLAB WHEREOCCURS
TRANSITION STRIP
RESILIENT FLOORING
DOOR AS SCHEDULED
L OF DOORC
METAL STUD FRAMING PERWALL TYPE SCHEDULE
CORNER GUARD, EXTENDEDFROM FLOOR FINISH TOUNDERSIDE OF CEILING
RETAINER CLIP
DRYWALL SCREW TYPICAL
5/8" GYPSUM BOARD
CORNER GUARD, EXTENDEDFROM FLOOR FINISH TOUNDERSIDE OF CEILING
RETAINER CLIP
DRYWALL SCREW TYPICAL
5/8" GYPSUM BOARD
WALL BASE, SEE INTERIOR FINISH SCHEDULE
ISOMETRIC VIEW
2"
CORNER GUARD AT END WALL
METAL STUD FRAMING PERWALL TYPE SCHEDULE
CRASH RAIL WHERE OCCURS
CERAMIC TILE
CONCRETE FLOOR SLAB,DEPRESSED SLAB WHEREOCCURS
QUARTZ STONE THRESHOLD
TERRAZZO FLOORING, SEEFINISH PLAN
DOOR AS SCHEDULED
4"
ANTI-FRACTURE MEMBRANE ASREQUIRED
CONCRETE FLOOR
CONCRETE FLOOR SLAB,DEPRESSED SLAB WHEREOCCURS
TRANSITION STRIP
RESILIENT FLOORING
DOOR AS SCHEDULED
L OF DOORC
PLEASE RECYCLE
Project Title
Agency Approval
Professional Seal
Drawing Title:
Designed:
Checked:
Reviewed
Date:
HMC Project No.
Project Status:
Drawing No.
DSN
RVW
010203040506070809
J
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
010203040506070809
SM
NOTES
KEYNOTES
T 602 575 2055/ www.hmcarchitects.com1001 N. 3rd Avenue, Studio 2 / Phoenix, AZ 85003
Drawn:DRW
CHK
Client Project No.
Notice of Extended Payment Provision: This contract allows the Owner to make payment within thirty(30) days after certification and approval of billings and estimates.
NOT FORCONSTRUCTION
C:\R
evit
Loca
l File
s\13
6303
0-BH
QC
-A14
_Cen
tral_
mla
mp.
rvt
10/17/2014 11:04:54 AM
CONSTRUCTION DOCUMENTS
A10.03
MISCELLANEOUS DETAILS
9/17/14
21772 South Ellsworth Loop RoadQueen Creek, AZ, 85142
Banner Health Center
BANNER HEALTH CENTER -QUEEN CREEK
1363030
No. Description DateA ISSUED FOR CONSTRUCTION 10/5/12
12" = 1'-0"
6TERRAZZO DIVIDER STRIP
12" = 1'-0"
3BTERRAZZO BASE DETAIL 12" = 1'-0"
3ATERRAZZO TO RESILIENT FLOORING
12" = 1'-0"
2TERRAZZO TO CARPET
12" = 1'-0"
1TERRAZZO AT CW SILL
6" = 1'-0"
5TILE TO RESILIENT FLOORING
12" = 1'-0"
9CARPET TO RESILIENT FLOORING
12" = 1'-0"
8RESILIENT TO RESILIENT
3" = 1'-0"
4CORNER GUARD 3" = 1'-0"
10CORNER GUARD AT END WALL ISOMETRIC
3" = 1'-0"
11CORNER GUARD AT END WALL 6" = 1'-0"
7TERRAZZA TO CERAMIC TILE
12" = 1'-0"
12RESILIENT TO CONCRETE