-1-
BARDONINSTALLATION INSTRUCTIONS
HIGH-SPEED TOUCHLESS HAND DRYER
K-5486T-B
�
�
�
�
Please read these instructions carefully to familiarizeyourself with the required tools, materials, and installationsequences. Follow the sections that pertain to yourparticular installation. This will help you avoid costlymistakes. In addition to proper installation, read alloperating and safety instructions.
All information in these instructions is based upon thelatest product information available at the time ofpublication. Kohler China reserves the right to makechanges in product characteristics, packaging, oravailability at any time without notice.
These instructions contain important care, cleaning, andwarranty information -
.please leave instructions for the
consumer
This product complies with GB 4706.1 and GB 4706.15.
�
�
�
�
-
GB 4706.1 GB 4706.15
BEFORE YOU BEGINBEFORE YOU BEGIN
SPECIFICATIONS
Activation
Dime sionsW H D
n
Voltage
PowerWarm Air
Cold Air
Detection Distance
Air Temperature
Operation Duration
Motor Type
Air Velocity
Activated by an infared sensor. Themachine operates automatically.
35~40 C 10cm from air outletAmbient temperature 25 C(77 F)
o
o o
45 sec(Self-protection automatic shutoff)
Induction with brush
30 4cm for A4 white paper
W H D262 225 184mm262 225 184mm
220V, 50Hz220V, 50Hz
1350W1350W
550W550W
10cm 35~40 C25 C (77 F)
o
o o
45( )
AC 220V 50Hz 105m/s 10%AC 220V 60Hz 110m/s 10%
30 4cm
AC 220V 50Hz 105m/s 10%AC 220V 60Hz 110m/s 10%
KOHLER CHINA INVESTMENT CO., LTD NO.158, JIANG CHANG SAN ROAD,JING'AN DISTRICT, SHANGHAI, PRC POST CODE: 200436
( ) 158 200436
©
©
Copyright Kohler China Investment Co., Ltd. 2016
2016
261
225
184
134
200
1302273-T01-A
-2-
WARNING:
WARNING: Danger of electric shock.
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
Danger of electric shock. Do not openthe casing.
Do not use thedevice at damper places such as the shower room.
Do not transform or disassemble thedevice to avoid fire or electric shock.
Use rated voltage. The device will breakdown if the rated voltage exceeds 10% and maycause fire or electric shock.
Use separated circuit to avoid fire causedby over heating of the shunt circuit.
To avoid danger, the damaged wire mustbe replaced by manufacture or other professionals.
Do not let children play on the device toavoid the device from dropping down.
Do not place other items on the device.
10%
60cm
40cm
110~120cm
STANDARD INSTALLATIONSTANDARD INSTALLATION
WARNING: Risk of electrical shock.
WARNING: Risk of electrical shock.
WARNING: Risk of electrical shock.
A licensed
electrician should make all electrical connections.
Connect only to
a circuit protected by a Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage Circuit-Breaker(ELCB).
Disconnect
power before servicing.
( ) ( )GFCI ELCB
�
�
This machine is equipped with an infrared sensor forautomatic activation.
The product is made in China.
�
�
1302273-T01-A
Problem
Hand dryerdoes notfunction
No warm air
Motor doesnot function
Check
Check the powerswitch.
Sensor wire is loose.
Sensor is damaged.
PTC heatingassembly isdamaged.
Check whetherambient temperatureexceeds 25 .
Motor is damaged.
Wind wheel is stuck.
Action
Turn on power.
Connect wire.
Contactprofessionals.
Heating isautomatically shutoff when ambienttemperatureexceeds 25 .
PTC
2525
Note: The device must be repaired by professionals.
Repair without technical assistance may damage the
parts or cause personal injury.
-3-
TROUBLESHOOTING
OPERATION DIAGRAMOPERATION DIAGRAM
L
N
Power
AC220V
Switch
Fuse
Circuit Board
Display Light
Temperature Control Probe
Sensor ProbeControl Relay
Motor
TemperatureControl Switch
Heater
Thermal Fuse
NOTE
1. Make sure the sensor is located min60cm(23 inch) above everthingbellow to prevent false triggers.
2. Never install hand dryer onto awooden or plastic wall finish.
3. Before installation, make sure thepower source complies withspecification of the machine.
1. 60cm
2.
3.
BEFORE INSTALLATIONBEFORE INSTALLATION
Minimum 60cm60cm
1302273-T01-A
-4-
3. Insert screws into dowels and tighten them. (Fig.2)
3. ( 2)
4. Connect AC power cable (Fig.3). The cable can be hidden.
4. ( 3)
Fig.22
Fig.33
INSTALLATION
A. Installation Steps
1. Paste the installation template at appropriate location on
the wall.
2. Drill four holes, dia 8mm insert plastic dowels. (Fig.1)
2. 8mm( 1)
A.
1.
8mm
Fig.11
Cap
Null Line
Grounding Line
Power Line
1302273-T01-A
Fig.44
B. Installation Check
1. Check AC power cable connection.
2. Check if AC power on.
3. Put outer cover back.
4. Insert security screws and tighten them.(Fig.4)
B.
1.
2.
3.
4. ( 4)
C. Test Running C.
D. Operation Instructions
1. The machine starts operating automatically when user'shands are put approximately 20cm (7.78") below thesensor located next to air louver. Whenever the hands aremoved out of sensing range, the machine will stop afterapprox. 0.5 sec.
2. The 0.2 sec time delay helps avoid false triggers byunexpected movements.
3. For safety reasons, the machine will immediately stopoperating when it is used continuously over 45 seconds.The machine resumes to standard function when handsare moved away.
D.
1. 20cm
0.5
2. 0.2
3. 45
-5-
Steps
1. Shakethedeviceslightly.
1.
2. Checkpowervoltage.
2.
3. Plug in. 3.
4. Puthandsbelow thedevice fordrying.
4.
Results
The device is firmlyfixed.
Use rated voltage.
Switch off externalpower.
Air goes out at ahigh speed.
Check the power ifthe display light isnot on.
The device may beburnt or causepersonal injury if notrunning under ratedvoltage.
There may beabnormal sounds orvibrations if thedevice is not firmlyfixed.
Check if hands aretoo far away fromthe sensor if there isno air going out.
Note
1302273-T01-A
E. Important Notice
1. Turn off power supply prior to removing outer case.
2. Turn off power supply before maintenance or cleaning. If
Casing is covered with dust, do not splash water onto it.
Use only damp sponge or cloth to wipe dirt off.
3. Do not use eradicator, abrasive powder or oil, acid or alkali
liquid detergent to clean casing.
4. Never try to put a small screw-driver or any other object
into the holes of air Louver from outside. This might cause
damage to the interior parts, and electric shock may occur.
5. Keep sensor case clean, never use any abrasive cleaning
agent, rough surface articles, steel brush or sandpaper to
rub the sensor case. This will make the sensor case dull
and decrease the sensitivity of sensor.
6. Do not dry other objects except hands to ensure the safety.
7. To avoid damage to the machine or cause physical harm to
the person, please keep the live parts away from water.
8. Do not bump the casing.
9. For indoor installation and use only.
E.
1.
2.
3.
4.
5.
6.
7.
8.
9.
-6-1302273-T01-A