4 Satellite Switched Monitored Basic & Metered Software Environmental Accessories Brackets Resources Educational Basic & Metered www.geistmfg.com Amps – Displays Current Draw in Amps RMS* Volts – Displays Voltage RMS* Watts – Displays power in Watts RMS*. Value is integration of instantaneous volts and current, referred to as Real Power. Power Factor – The ratio of Real Power to Apparent Power. Apparent Power is the calculation of Volts RMS* and Amps RMS*. Basic & Metered Basic PDUs are available in a wide range of power capacities and configurations; however, they all serve the same function of distributing power from a single input to multiple receptacles. Reliable power distribution is a key cornerstone to every mission critical data center. The Geist PM series meters can be configured as a Power Meter or Current Meter. The Power Meter provides a scrolling display of four critical power measurements which include Power Factor, Amps, Volts and Watts. The Current Meter version provides an accurate True RMS reading of the current draw. SPECIFICATION: +/- 2% Accuracy with Full Scale 50/60Hz sine wave input * RMS - Acronym for Root Mean Squared
Transcript
Page 1: Basic & Metered - objects.eanixter.com

4

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

Basic & Metered

w w w . g e i s t m f g . c o m

Amps – Displays Current Draw in Amps RMS* Volts – Displays Voltage RMS*

Watts – Displays power in Watts RMS*. Value is integration of instantaneous volts and current, referred to as Real Power.

Power Factor – The ratio of Real Power to Apparent Power. Apparent Power is the calculation of Volts RMS* and Amps RMS*.

Basic & Metered

Basic PDUs are available in a wide range of power capacities and configurations; however, they all serve the same function of distributing power from a single input to multiple receptacles. Reliable power distribution is a key cornerstone to every mission critical data center.

The Geist PM series meters can be confi gured as a Power Meter or Current Meter. The Power Meter provides a scrolling display of four critical power measurements which include Power Factor, Amps, Volts and Watts. The Current Meter version provides an accurate True RMS reading of the current draw.

SPECIFICATION:

+/- 2% Accuracy with Full Scale 50/60Hz sine wave input

* RMS - Acronym for Root Mean Squared

Page 2: Basic & Metered - objects.eanixter.com

5

SatelliteMonitored

Basic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

Basic & Metered

8 0 0 - 4 3 2 - 3 2 1 9

Basic & Metered

As IT equipment continues to draw increasing amounts of power, the need to meter current consumption at the rack is paramount. Metered PDUs contain a local meter to provide essential real-time information crucial for rack load capacity and balancing. This data is critical to insure breakers are not tripped by exceeding maximum current capacity. Additional information including voltage, wattage and power factor provide a more comprehensive power overview ideal for preventative maintenance and rack diagnostics.

The Geist CM-3 series scrolling 3 Phase Current Meter provides True RMS current readings for 3 Phase PDU’s. The CM-3 meter scrolls through each phase reading, eliminating the need for separate meters on each phase. Load balancing your 3 Phase installation has never been easier.

SPECIFICATION:

+/- 3.5% Accuracy with Full Scale 50/60Hz sine wave input

Circuit 2 – Represents Phase Y Circuit 3 – Represents Phase Z

Circuit 1 – Represents Phase XAmps – Displays current draw in Amps RMS*

* RMS - Acronym for Root Mean Squared

Page 3: Basic & Metered - objects.eanixter.com

6

1.4kW 15 Amp, 120 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

LINE DRAWING 1 2 3 4

AMPS 15 15 15 15

VOLTS 120 120 120 120

TOTAL RECEPTACLE QTY 6 8 6 6

RECEPTACLE TYPE / QTY 5-15R / 6 5-15R / 8 5-15R / 6 5-15R / 6

RECEPTACLES PER BREAKER 6 8 6 6

RECEPTACLE CENTER TO CENTER SPACING (INCHES) 2.5 3.2 N/A N/A

THERMAL CIRCUIT BREAKER YES YES YES YES

BREAKER AMPERAGE / QTY 15 / 1 15 / 1 15 / 1 15 / 1

ON-OFF SWITCH YES YES YES YES

10’ POWER CORD 1 1 1 1

STRAIGHT-BLADE PLUG 5-15P 5-15P 5-15P 5-15P

TWIST-LOCK PLUG OPT OPT OPT OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS NO YES NO YES

FLUSH MOUNTING YES OPT YES OPT

DIMENSIONS H (INCHES) 1.72 1.72 1.72 1.72

DIMENSIONS W 17 17 17 17

DIMENSIONS D 3.75 4.5 3.75 4.5

BRF0

60-10

• UL® & c-UL® Listed 60950 BRT0

60-10

BRX0

80-10

BR06

0-10

1

2

3

4

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

No Breaker and No Switch available on the following:

BR060-10 = JRN062-101D15ST5

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

Page 4: Basic & Metered - objects.eanixter.com

7

15 Amp, 120 Volt, 1.4kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

BR10

0-10

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

No Breaker and No Switch available on the following:

BR100-10 = JRN102-101D15ST5

BRC100-10 = JRCN102-101D15ST5

BR120-10 = JRN122-101D15ST5

BRC1

00-10

BRFC

100-1

0

BR12

0-10

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

LINE DRAWING 1 2 3 4 5

AMPS 15 15 15 15 15

VOLTS 120 120 120 120 120

TOTAL RECEPTACLE QTY 10 10 10 10 12

RECEPTACLE TYPE / QTY 5-15R / 10 5-15R / 10 5-15R / 10 5-15R / 10 5-15R / 12

RECEPTACLES PER BREAKER 10 10 10 10 12

THERMAL CIRCUIT BREAKER YES YES YES YES YES

BREAKER AMPERAGE / QTY 15 / 1 15 / 1 15 / 1 15 / 1 15 / 1

ON-OFF SWITCH YES YES YES YES YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS NO NO YES * YES * NO

CURRENT MONITORING - LOCAL AMPS NO NO OPT * OPT * NO

MONITORING N/A N/A AGGREGATE AGGREGATE N/A

10’ POWER CORD 1 1 1 1 1

STRAIGHT-BLADE PLUG 5-15P 5-15P 5-15P 5-15P 5-15P

TWIST-LOCK PLUG OPT OPT OPT OPT OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS NO YES OPT YES NO

FLUSH MOUNTING YES OPT YES OPT YES

DIMENSIONS H (INCHES) 1.72 1.72 1.72 1.72 1.72

DIMENSIONS W 17 17 17 17 17

DIMENSIONS D 3.75 4.5 4.5 4.5 3.75

BRF1

00-10

2

3

4

5

1

Page 5: Basic & Metered - objects.eanixter.com

8

1.4kW 15 Amp, 120 Volt, Surge Suppressed

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

SPT0

64-10

SPX0

84-10

SP06

4-10

• UL® & c-UL® Listed 60950• Surge Suppression: 330V, 720 Joules SP

F064

-10

1

2

3

4

LINE DRAWING 1 2 3 4

AMPS 15 15 15 15

VOLTS 120 120 120 120

TOTAL RECEPTACLE QTY 6 8 6 6

RECEPTACLE TYPE / QTY 5-15R / 6 5-15R / 8 5-15R / 6 5-15R / 6

RECEPTACLES PER BREAKER 6 8 6 6

RECEPTACLE CENTER TO CENTER SPACING (INCHES) 2.5 3.2 N/A N/A

THERMAL CIRCUIT BREAKER YES YES YES YES

BREAKER AMPERAGE / QTY 15 / 1 15 / 1 15 / 1 15 / 1

ON-OFF SWITCH YES YES YES YES

10’ POWER CORD 1 1 1 1

STRAIGHT-BLADE PLUG 5-15P 5-15P 5-15P 5-15P

TWIST-LOCK PLUG OPT OPT OPT OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS NO YES NO YES

FLUSH MOUNTING YES OPT YES OPT

DIMENSIONS H (INCHES) 1.72 1.72 1.72 1.72

DIMENSIONS W 17 17 17 17

DIMENSIONS D 3.75 4.5 3.75 4.5

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 6: Basic & Metered - objects.eanixter.com

9

15 Amp, 120 Volt, Surge Suppressed, 1.4kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

SP10

4-10

SPF1

04-10

SPC1

04-10

SPFC

104-1

0

SP12

4-10

• UL® & c-UL® Listed 60950• Surge Suppression: 330V, 720 Joules* Detailed meter specs available on pages 4 & 5.

LINE DRAWING 1 2 3 4 5

AMPS 15 15 15 15 15

VOLTS 120 120 120 120 120

TOTAL RECEPTACLE QTY 10 10 10 10 12

RECEPTACLE TYPE / QTY 5-15R / 10 5-15R / 10 5-15R / 10 5-15R / 10 5-15R / 12

RECEPTACLES PER BREAKER 10 10 10 10 12

THERMAL CIRCUIT BREAKER YES YES YES YES YES

BREAKER AMPERAGE / QTY 15 / 1 15 / 1 15 / 1 15 / 1 15 / 1

ON-OFF SWITCH YES YES YES YES YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS NO NO YES * YES * NO

CURRENT MONITORING - LOCAL AMPS NO NO OPT * OPT * NO

MONITORING N/A N/A AGGREGATE AGGREGATE N/A

10’ POWER CORD 1 1 1 1 1

STRAIGHT-BLADE PLUG 5-15P 5-15P 5-15P 5-15P 5-15P

TWIST-LOCK PLUG OPT OPT OPT OPT OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS NO YES OPT YES NO

FLUSH MOUNTING YES OPT YES OPT YES

DIMENSIONS H (INCHES) 1.72 1.72 1.72 1.72 1.72

DIMENSIONS W 17 17 17 17 17

DIMENSIONS D 3.75 4.5 4.5 4.5 3.75

1

2

3

4

5

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 7: Basic & Metered - objects.eanixter.com

10

1.4kW 15 Amp, 120 Volt

LINE DRAWING 1 2 3 4 5 6

AMPS 15 15 15 15 15 15

VOLTS 120 120 120 120 120 120

TOTAL RECEPTACLE QTY 8 8 10 14 20 20

RECEPTACLE TYPE / QTY 5-15R / 8 5-15R / 8 5-15R / 10 5-15R / 14 5-15R / 20 5-15R / 20

RECEPTACLES PER BREAKER 8 8 10 14 20 20

RECEPTACLE CENTER TO CENTER SPACING (INCHES) 1.25 2 2.95 2.95 2.8 2.8

RECEPTACLE ORIENTATION INLINE INLINE INLINE INLINE INLINE INLINE

THERMAL CIRCUIT BREAKER YES YES YES YES YES YES

BREAKER AMPERAGE / QTY 15 / 1 15 / 1 15 / 1 15 / 1 15 / 1 15 / 1

ON-OFF SWITCH YES YES YES YES YES YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS NO NO NO NO NO YES *

CURRENT MONITORING - LOCAL AMPS NO NO NO NO NO OPT *

MONITORING N/A N/A N/A N/A N/A AGGREGATE

10’ POWER CORD 1 1 1 1 1 1

STRAIGHT-BLADE PLUG 5-15P 5-15P 5-15P 5-15P 5-15P 5-15P

TWIST-LOCK PLUG OPT OPT OPT OPT OPT OPT

HORIZONTAL/PANEL MOUNTING BRACKETS YES NO NO NO NO NO

1 BOTTOM & 1 TOP MOUNTING CLIP YES YES YES YES NO NO

1 BOTTOM & 2 TOP MOUNTING CLIPS NO NO NO NO YES YES

DIMENSIONS L (INCHES) 17 24 38.5 47.5 66.25 66.25

DIMENSIONS W 1.61 1.61 1.61 1.61 1.61 1.61

DIMENSIONS D 1.61 1.61 1.61 1.61 1.61 1.61

NSVC

140-1

01S1

5NS

VB20

0-101

S15

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5. NS

VL08

0--10

1S15

NSVK

080-1

01S1

5NS

VA10

0-101

S15

MODIFY TO MEET YOUR NEEDS

Rotate Receptacle Orientation 90º: S= Inline / R= Rotated Cord Length (Feet) 02-15 (Plug Attached)

No Switch Option: Insert N before fi rst number in part number Twist-Lock Plug Option: Add TL to end of part number

Current Monitoring Option: Replace C with A in part number

NSVB

C200

-101S

15

1 2 3 4 5 6

ew ew ew ew ew ew

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

Page 8: Basic & Metered - objects.eanixter.com

11

15 Amp, 120 Volt, 1.4kW

MJCN

122-1

01S1

5ST5

MJCN

122-1

01S1

5ST5

IGMJ

BN20

2-101

S15S

T5MJ

BN20

2-101

S15S

T5IG

MODIFY TO MEET YOUR NEEDS

Rotate Receptacle Orientation 90º: S= Inline / R= Rotated

Cord Length (Feet) 02-15 (Plug Attached)

Plug Type: ST= Straight-Blade / TL= Twist-Lock

LINE DRAWING 1 2 3 4

AMPS 15 15 15 15

VOLTS 120 120 120 120

TOTAL RECEPTACLE QTY 12 12 20 20

RECEPTACLE TYPE / QTY 5-15R / 12 5-15R / 12 5-15R / 20 5-15R / 20

RECEPTACLES CENTER TO CENTER SPACING (INCHES) 3.5 3.5 3 3

RECEPTACLE ORIENTATION INLINE INLINE INLINE INLINE

ISOLATED GROUND3’ EXTERNAL GROUNDING WIRE NO YES NO YES

CIRCUIT BREAKER / ON-OFF SWITCH NO NO NO NO

10’ POWER CORD 1 1 1 1

STRAIGHT-BLADE PLUG 5-15P 5-15P 5-15P 5-15P

TWIST-LOCK PLUG OPT OPT OPT OPT

MOUNTING BRACKETS YES YES YES YES

DIMENSIONS L (INCHES) 47.5 47.5 66.25 66.25

DIMENSIONS W 1.25 1.25 1.25 1.25

DIMENSIONS D 1.1 1.1 1.1 1.1

• UL® & c-UL® Listed 60950

1 2 3 4

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

Page 9: Basic & Metered - objects.eanixter.com

12

1.4kW 15 Amp, 120 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

LINE DRAWING 1 2 3

AMPS 15 15 15

VOLTS 120 120 120

TOTAL RECEPTACLE QTY 6 10 10

RECEPTACLE TYPE / QTY 5-15R / 6 5-15R / 10 5-15R / 10

RECEPTACLES PER BREAKER 6 10 10

RECEPTACLE CENTER TO CENTER SPACING (INCHES) 1.75 N/A N/A

THERMAL CIRCUIT BREAKER YES YES YES

BREAKER AMPERAGE / QTY 15 / 1 15 / 1 15 / 1

ON-OFF SWITCH YES YES YES

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO NO YES *

CURRENT MONITORING - LOCALAMPS NO NO OPT *

MONITORING N/A N/A AGGREGATE

10’ POWER CORD 1 1 1

STRAIGHT-BLADE PLUG 5-15P 5-15P 5-15P

TWIST-LOCK PLUG OPT OPT OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS YES NO NO

FULL-LENGTH VERTICAL MOUNTING BRACKET NO YES YES

DIMENSIONS L (INCHES) 17 38.5 38.5

DIMENSIONS W 1.72 1.85 1.85

DIMENSIONS D 1.61 1.3 1.3

VRTL

060-1

0

VRTA

100-1

0

VRTA

C100

-10

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

1 2 3

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 10: Basic & Metered - objects.eanixter.com

13

15 Amp, 120 Volt, 1.4kW

ew

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

LINE DRAWING 1 2 3 4

AMPS 15 15 15 15

VOLTS 120 120 120 120

TOTAL RECEPTACLE QTY 14 14 20 20

RECEPTACLE TYPE / QTY 5-15R / 14 5-15R / 14 5-15R / 20 5-15R / 20

RECEPTACLES PER BREAKER 14 14 20 20

THERMAL CIRCUIT BREAKER YES YES YES YES

BREAKER AMPERAGE / QTY 15 / 1 15 / 1 15 / 1 15 / 1

ON-OFF SWITCH YES YES YES YES

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES *

CURRENT MONITORING - LOCALAMPS NO OPT* NO OPT *

MONITORING N/A AGGREGATE N/A AGGREGATE

10’ POWER CORD 1 1 1 1

STRAIGHT-BLADE PLUG 5-15P 5-15P 5-15P 5-15P

TWIST-LOCK PLUG OPT OPT OPT OPT

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

DIMENSIONS L (INCHES) 47.5 47.5 66.25 66.25

DIMENSIONS W 1.85 1.85 1.85 1.85

DIMENSIONS D 1.3 1.3 1.3 1.3

VRTC

140-1

0

VRTB

200-1

0

VRTB

C200

-10

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5. VR

TCC1

40-10

1 2 3 4

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 11: Basic & Metered - objects.eanixter.com

14

1.4kW 15 Amp, 120 Volt, Surge Suppressed

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

LINE DRAWING 1 2 3 4 5 6

AMPS 15 15 15 15 15 15

VOLTS 120 120 120 120 120 120

TOTAL RECEPTACLE QTY 8 8 10 14 20 20

RECEPTACLE TYPE / QTY 5-15R / 8 5-15R / 8 5-15R / 10 5-15R / 14 5-15R / 20 5-15R / 20

RECEPTACLES PER BREAKER 8 8 10 14 20 20

RECEPTACLE CENTER TO CENTER SPACING (INCHES) 1.25 2 2.95 2.95 2.8 2.8

RECEPTACLE ORIENTATION INLINE INLINE INLINE INLINE INLINE INLINE

THERMAL CIRCUIT BREAKER YES YES YES YES YES YES

BREAKER AMPERAGE / QTY 15 / 1 15 / 1 15 / 1 15 / 1 15 / 1 15 / 1

ON-OFF SWITCH YES YES YES YES YES YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS NO NO NO NO NO YES *

CURRENT MONITORING - LOCAL AMPS NO NO NO NO NO OPT *

MONITORING N/A N/A N/A N/A N/A AGGREGATE

10’ POWER CORD 1 1 1 1 1 1

STRAIGHT-BLADE PLUG 5-15P 5-15P 5-15P 5-15P 5-15P 5-15P

TWIST-LOCK PLUG OPT OPT OPT OPT OPT OPT

HORIZONTAL/PANEL MOUNTING BRACKETS YES NO NO NO NO NO

1 BOTTOM & 1 TOP MOUNTING CLIP YES YES YES YES NO NO

1 BOTTOM & 2 TOP MOUNTING CLIPS NO NO NO NO YES YES

DIMENSIONS L (INCHES) 17 24 38.5 47.5 66.25 66.25

DIMENSIONS W 1.61 1.61 1.61 1.61 1.61 1.61

DIMENSIONS D 1.61 1.61 1.61 1.61 1.61 1.61

VSSC

144-1

01S1

5VS

SB20

4-101

S15

• UL® & c-UL® Listed 60950• Surge Suppression: 330V, 720 Joules* Detailed meter specs available on pages 4 & 5. VS

SL08

4--10

1S15

VSSK

084-1

01S1

5VS

SA10

4-101

S15

MODIFY TO MEET YOUR NEEDS

Rotate Receptacle Orientation 90º: S= Inline / R= Rotated Cord Length (Feet) 02-15 (Plug Attached)

No Switch Option: Insert N before fi rst number in part number Twist-Lock Plug Option: Add TL to end of part number

Current Monitoring Option: Replace C with A in part number

VSSB

C204

-101S

15

1 2 3 4 5 6

ew ew ew ew ew ew

Page 12: Basic & Metered - objects.eanixter.com

15

15 Amp, 120 Volt, Surge Suppressed 1.4kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

SVRL

064-1

0SV

RA10

4-10

SVRA

C104

-10

LINE DRAWING 1 2 3

AMPS 15 15 15

VOLTS 120 120 120

TOTAL RECEPTACLE QTY 6 10 10

RECEPTACLE TYPE / QTY 5-15R / 6 5-15R / 10 5-15R / 10

RECEPTACLES PER BREAKER 6 10 10

RECEPTACLES CENTER TO CENTER SPACING (INCHES) 1.75 N/A N/A

THERMAL CIRCUIT BREAKER YES YES YES

BREAKER AMPERAGE / QTY 15 / 1 15 / 1 15 / 1

ON-OFF SWITCH YES YES YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS NO NO YES *

CURRENT MONITORING - LOCAL AMPS NO NO OPT *

MONITORING N/A N/A AGGREGATE

10’ POWER CORD 1 1 1

STRAIGHT-BLADE PLUG 5-15P 5-15P 5-15P

TWIST-LOCK PLUG OPT OPT OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS YES NO NO

FULL-LENGTH VERTICAL MOUNTING BRACKET NO YES YES

DIMENSIONS L (INCHES) 17 38.5 38.5

DIMENSIONS W 1.72 1.85 1.85

DIMENSIONS D 1.61 1.3 1.3

• UL® & c-UL® Listed 60950• Surge Suppression: 330V, 720 Joules* Detailed meter specs available on pages 4 & 5.

1 2 3

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 13: Basic & Metered - objects.eanixter.com

16

1.4kW 15 Amp, 120 Volt, Surge Suppressed

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

LINE DRAWING 1 2 3 4

AMPS 15 15 15 15

VOLTS 120 120 120 120

TOTAL RECEPTACLE QTY 14 14 20 20

RECEPTACLE TYPE / QTY 5-15R / 14 5-15R / 14 5-15R / 20 5-15R / 20

RECEPTACLES PER BREAKER 14 14 20 20

THERMAL CIRCUIT BREAKER YES YES YES YES

BREAKER AMPERAGE / QTY 15 / 1 15 / 1 15 / 1 15 / 1

ON-OFF SWITCH YES YES YES YES

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES* NO YES*

CURRENT MONITORING - LOCALAMPS NO OPT* NO OPT*

MONITORING N/A AGGREGATE N/A AGGREGATE

10’ POWER CORD 1 1 1 1

STRAIGHT-BLADE PLUG 5-15P 5-15P 5-15P 5-15P

TWIST-LOCK PLUG OPT OPT OPT OPT

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

DIMENSIONS L (INCHES) 47.5 47.5 66.25 66.25

DIMENSIONS W 1.85 1.85 1.85 1.85

DIMENSIONS D 1.3 1.3 1.3 1.3

SVRC

144-1

0

SVRB

204-1

0• UL® & c-UL® Listed 60950• Surge Suppression: 330V, 720 Joules* Detailed meter specs available on pages 4 & 5.

ew

SVRC

C144

-10

SVRB

C204

-10

1 2 3 4

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 14: Basic & Metered - objects.eanixter.com

17

20 Amp, 120 Volt, 1.9kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

• UL® & c-UL® Listed 60950 BR06

0-102

3

BRF0

60-10

23

1

2

LINE DRAWING 1 2

AMPS 20 20

VOLTS 120 120

TOTAL RECEPTACLE QTY 6 6

RECEPTACLE TYPE / QTY 5-15R / 6 5-15R / 6

RECEPTACLES PER BREAKER 6 6

THERMAL CIRCUIT BREAKER YES YES

BREAKER AMPERAGE / QTY 20 / 1 20 / 1

ON-OFF SWITCH YES YES

10’ POWER CORD 1 1

STRAIGHT-BLADE PLUG 5-20P 5-20P

TWIST-LOCK PLUG OPT OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKET NO YES

FLUSH MOUNTING YES OPT

DIMENSIONS H (INCHES) 1.72 1.72

DIMENSIONS W 17 17

DIMENSIONS D 3.75 4.5

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

No Breaker and No Switch available on the following:

BR060-1023 = JRN062-102D20ST5

Page 15: Basic & Metered - objects.eanixter.com

18

1.9kW 20 Amp, 120 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

LINE DRAWING 1 2 3 4 5

AMPS 20 20 20 20 20

VOLTS 120 120 120 120 120

TOTAL RECEPTACLE QTY 10 10 10 10 12

RECEPTACLE TYPE / QTY 5-20R / 10 5-20R / 10 5-20R / 10 5-20R / 10 5-20R / 12

RECEPTACLES PER BREAKER 10 10 10 10 12

THERMAL CIRCUIT BREAKER YES YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 1 20 / 1 20 / 1 20 / 1 20 / 1

ON-OFF SWITCH YES YES YES YES YES

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO NO YES* YES* NO

CURRENT MONITORING - LOCALAMPS NO NO OPT* OPT* NO

MONITORING N/A N/A AGGREGATE AGGREGATE N/A

10’ POWER CORD 1 1 1 1 1

STRAIGHT-BLADE PLUG 5-20P 5-20P 5-20P 5-20P 5-20P

TWIST-LOCK PLUG OPT OPT OPT OPT OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS NO YES OPT YES NO

FLUSH MOUNTING YES OPT YES OPT YES

DIMENSIONS H (INCHES) 1.72 1.72 1.72 1.72 1.72

DIMENSIONS W 17 17 17 17 17

DIMENSIONS D 3.75 4.5 4.5 4.5 3.75

BR10

0-102

5BR

F100

-1025

BRC1

00-10

25

BRFC

100-1

025

BR12

0-102

6

1

2

3

4

5

• UL® & c-UL® Listed 60950• Surge Suppression: 330V, 720 Joules* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

No Breaker and No Switch available on the following:

BR100-1025 = JRN102-102D20ST5

BRC100-1025 = JRCN102-102D20ST5

BR120-1026 = JRN122-102D20ST5

Page 16: Basic & Metered - objects.eanixter.com

19

20 Amp, 120 Volt, 1.9kW (x2)

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

JRN1

20-10

2D20

DST5

2JRN

202-1

02D2

0DST

52J

RCN2

02-10

2D20

DST5

• UL® & c-UL® Listed 60950• Multi-input units contain color-coded receptacle confi gurations and/or labeling for easy identifi cation and load balancing* Detailed meter specs available on pages 4 & 5.

LINE DRAWING 1 2 3 4 5

QUANTITY OF INPUTS 2 2 2 2 2

AMPS 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2

VOLTS 120 x 2 120 x 2 120 x 2 120 x 2 120 x 2

TOTAL RECEPTACLE QTY 12 20 20 20 20

RECEPTACLE TYPE / QTY 5-20R / 12 5-20R / 20 5-20R / 20 5-20R / 20 5-20R / 20

RECEPTACLES PER INPUT 6 10 10 10 10

RECEPTACLES PER BREAKER 6 N/A N/A 10 10

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD NO NO NO YES YES

THERMAL CIRCUIT BREAKER YES NO NO NO NO

BREAKER POLE CONFIGURATION SINGLE N/A N/A SINGLE SINGLE

BREAKER AMPERAGE / QTY 20 / 2 N/A N/A 20 / 2 20 / 2

ON-OFF SWITCH NO NO NO BREAKER BREAKER

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS NO NO YES x 2 * NO YES x 2 *

CURRENT MONITORING - LOCAL AMPS NO NO OPT * NO OPT*

MONITORING N/A N/A CIRCUIT N/A CIRCUIT

10’ POWER CORD 2 2 2 2 2

STRAIGHT-BLADE PLUG (2) 5-20P (2) 5-20P (2) 5-20P (2) 5-20P (2) 5-20P

TWIST-LOCK PLUG OPT OPT OPT OPT OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS YES NO NO NO NO

2U RECESSED MOUNTING BRACKETS NO YES YES YES YES

DIMENSIONS H (INCHES) 1.72 3.39 3.39 3.39 3.39

DIMENSIONS W 17 17 17 17 17

DIMENSIONS D 4.5 6 6 6 6

2JR2

00-10

2D20

DST5

2JRC

200-1

02D2

0DST

5

1

2

3

4

5

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 17: Basic & Metered - objects.eanixter.com

20

1.9kW 20 Amp, 120 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

LINE DRAWING 1 2

AMPS 20 20

VOLTS 120 120

TOTAL RECEPTACLE QTY 6 6

RECEPTACLE TYPE / QTY L5-20R / 6 L5-20R / 6

RECEPTACLES PER INPUT 6 6

RECEPTACLES PER BREAKER N/A N/A

CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD NO NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS NO YES *

CURRENT MONITORING - LOCAL AMPS NO OPT *

MONITORING N/A AGGREGATE

10’ POWER CORD 1 1

STRAIGHT-BLADE PLUG 5-20P 5-20P

TWIST-LOCK PLUG OPT OPT

2U RECESSED MOUNTING BRACKETS YES YES

DIMENSIONS H (INCHES) 3.39 3.39

DIMENSIONS W 17 17

DIMENSIONS D 6 6

2JRN

062-1

02L2

0ST5

2JRC

N062

-102L

20ST

5

1

2

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 18: Basic & Metered - objects.eanixter.com

21

20 Amp, 120 Volt, Surge Suppressed, 1.9kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

LINE DRAWING 1 2

AMPS 20 20

VOLTS 120 120

TOTAL RECEPTACLE QTY 6 6

RECEPTACLE TYPE / QTY 5-20R / 6 5-20R / 6

RECEPTACLES PER BREAKER 6 6

THERMAL CIRCUIT BREAKER YES YES

BREAKER AMPERAGE / QTY 20 / 1 20 / 1

ON-OFF SWITCH YES YES

10’ POWER CORD 1 1

STRAIGHT-BLADE PLUG 5-20P 5-20P

TWIST-LOCK PLUG OPT OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS NO YES

FLUSH MOUNTING YES OPT

DIMENSIONS H (INCHES) 1.72 1.72

DIMENSIONS W 17 17

DIMENSIONS D 3.75 4.5

SP06

4-102

3SP

F064

-1023

• UL® & c-UL® Listed 60950• Surge Suppression: 330V, 720 Joules

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

1

2

Page 19: Basic & Metered - objects.eanixter.com

22

1.9kW 20 Amp, 120 Volt, Surge Suppressed

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

SPC1

04-10

25

SPFC

104-1

025

SP12

4-102

6

LINE DRAWING 1 2 3 4 5

AMPS 20 20 20 20 20

VOLTS 120 120 120 120 120

TOTAL RECEPTACLE QTY 10 10 10 10 12

RECEPTACLE TYPE / QTY 5-20R / 10 5-20R / 10 5-20R / 10 5-20R / 10 5-20R / 12

RECEPTACLES PER BREAKER 10 10 10 10 12

THERMAL CIRCUIT BREAKER YES YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 1 20 / 1 20 / 1 20 / 1 20 / 1

ON-OFF SWITCH YES YES YES YES YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS NO NO YES * YES * NO

CURRENT MONITORING - LOCAL AMPS NO NO OPT * OPT * NO

MONITORING N/A N/A AGGREGATE AGGREGATE N/A

10’ POWER CORD 1 1 1 1 1

STRAIGHT-BLADE PLUG 5-20P 5-20P 5-20P 5-20P 5-20P

TWIST-LOCK PLUG OPT OPT OPT OPT OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS NO YES OPT YES NO

FLUSH MOUNTING YES OPT YES OPT YES

DIMENSIONS H (INCHES) 1.72 1.72 1.72 1.72 1.72

DIMENSIONS W 17 17 17 17 17

DIMENSIONS D 3.75 4.5 4.5 4.5 3.75

• UL® & c-UL® Listed 60950• Surge Suppression: 330V, 720 Joules* Detailed meter specs available on pages 4 & 5. SP

F104

-1025

2

3

4

5

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

SP10

4-102

51

Page 20: Basic & Metered - objects.eanixter.com

23

20 Amp, 120 Volt, 1.9kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

NSVL

080-1

02S2

0NS

VK08

0-102

S20

NSVA

100-1

02S2

0NS

VC14

0-102

S20

NSVB

200-1

02S2

0NS

VBC2

00-10

2S20

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

1 2 3 4 5 6LINE DRAWING 1 2 3 4 5 6

AMPS 20 20 20 20 20 20

VOLTS 120 120 120 120 120 120

TOTAL RECEPTACLE QTY 8 8 10 14 20 20

RECEPTACLE TYPE / QTY 5-20R / 8 5-20R / 8 5-20R / 10 5-20R / 14 5-20R / 20 5-20R / 20

RECEPTACLES PER BREAKER 8 8 10 14 20 20

RECEPTACLE CENTER TO CENTER SPACING (INCHES) 1.25 2 2.95 2.95 2.8 2.8

RECEPTACLE ORIENTATION INLINE INLINE INLINE INLINE INLINE INLINE

THERMAL CIRCUIT BREAKER YES YES YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 1 20 / 1 20 / 1 20 / 1 20 / 1 20 / 1

ON-OFF SWITCH YES YES YES YES YES YES

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO NO NO NO NO YES *

CURRENT MONITORING - LOCALAMPS NO NO NO NO NO OPT *

MONITORING N/A N/A N/A N/A N/A AGGREGATE

10’ POWER CORD 1 1 1 1 1 1

STRAIGHT-BLADE PLUG 5-20P 5-20P 5-20P 5-20P 5-20P 5-20P

TWIST-LOCK PLUG OPT OPT OPT OPT OPT OPT

HORIZONTAL/PANEL MOUNTING BRACKETS YES NO NO NO NO NO

ONE BOTTOM & ONE TOP MOUNTING CLIP YES YES YES YES NO NO

ONE BOTTOM & TWO TOP MOUNTING CLIPS NO NO NO NO YES YES

DIMENSIONS L (INCHES) 17 24 38.5 47.5 66.25 66.25

DIMENSIONS W 1.61 1.61 1.61 1.61 1.61 1.61

DIMENSIONS D 1.61 1.61 1.61 1.61 1.61 1.61

MODIFY TO MEET YOUR NEEDS

Rotate Receptacle Orientation 90º: S= Inline / R= Rotated Cord Length (Feet) 02-15 (Plug Attached)

No Switch Option: Insert N before fi rst number in part number Twist-Lock Plug Option: Add TL to end of part number

Current Monitoring Option: Replace C with A in part number

Page 21: Basic & Metered - objects.eanixter.com

24

1.9kW 20 Amp, 120 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

LINE DRAWING 1 2 3 4

AMPS 20 20 20 20

VOLTS 120 120 120 120

TOTAL RECEPTACLE QTY 12 12 20 20

RECEPTACLE TYPE / QTY 5-20R / 12 5-20R / 12 5-20R / 20 5-20R / 20

RECEPTACLES CENTER TO CENTER SPACING (INCHES) 3.5 3.5 3 3

RECEPTACLE ORIENTATION INLINE INLINE INLINE INLINE

ISOLATED GROUND3’ EXTERNAL GROUNDING WIRE NO YES NO YES

CIRCUIT BREAKER / ON-OFF SWITCH NO NO NO NO

10’ POWER CORD 1 1 1 1

STRAIGHT-BLADE PLUG 5-20P 5-20P 5-20P 5-20P

TWIST-LOCK PLUG OPT OPT OPT OPT

MOUNTING BRACKETS YES YES YES YES

DIMENSIONS L (INCHES) 47.5 47.5 66.25 66.25

DIMENSIONS W 1.25 1.25 1.25 1.25

DIMENSIONS D 1.1 1.1 1.1 1.1

MJCN

122-1

02S2

0ST5

MJCN

122-1

02S2

0ST5

IGMJ

BN20

2-102

S20S

T5MJ

BN20

2-102

S20S

T5IG

MODIFY TO MEET YOUR NEEDS

Rotate Receptacle Orientation 90º: S= Inline / R= Rotated

Cord Length (Feet) 02-15 (Plug Attached)

Plug Type: ST= Straight-Blade / TL= Twist-Lock

1 2 3 4

• UL® & c-UL® Listed 60950

Page 22: Basic & Metered - objects.eanixter.com

25

20 Amp, 120 Volt, 1.9kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

VRTL

060-1

023

VRTA

100-1

025

VRTA

C100

-1025

LINE DRAWING 1 2 3

AMPS 20 20 20

VOLTS 120 120 120

TOTAL RECEPTACLE QTY 6 10 10

RECEPTACLE TYPE / QTY 5-20R / 6 5-20R / 10 5-20R / 10

RECEPTACLES PER BREAKER 6 10 10

THERMAL CIRCUIT BREAKER YES YES YES

BREAKER AMPERAGE / QTY 20 / 1 20 / 1 20 / 1

ON-OFF SWITCH YES YES YES

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO NO YES *

CURRENT MONITORING - LOCALAMPS NO NO OPT *

MONITORING N/A N/A AGGREGATE

10’ POWER CORD 1 1 1

STRAIGHT-BLADE PLUG 5-20P 5-20P 5-20P

TWIST-LOCK PLUG OPT OPT OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS YES NO NO

FULL-LENGTH VERTICAL MOUNTING BRACKET NO YES YES

DIMENSIONS L (INCHES) 17 38.5 38.5

DIMENSIONS W 1.72 1.85 1.85

DIMENSIONS D 1.61 1.3 1.3

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

1 2 3

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 23: Basic & Metered - objects.eanixter.com

26

1.9kW 20 Amp, 120 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

ew

VRTB

C200

-1021

0

VRTC

140-1

027

VRTB

200-1

0210

LINE DRAWING 1 2 3 4

AMPS 20 20 20 20

VOLTS 120 120 120 120

TOTAL RECEPTACLE QTY 14 14 20 20

RECEPTACLE TYPE / QTY 5-20R / 14 5-20R / 14 5-20R / 20 5-20R / 20

RECEPTACLES PER BREAKER 14 14 20 20

THERMAL CIRCUIT BREAKER YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 1 20 / 1 20 / 1 20 / 1

ON-OFF SWITCH YES YES YES YES

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES *

CURRENT MONITORING - LOCALAMPS NO OPT * NO OPT *

MONITORING N/A AGGREGATE N/A AGGREGATE

10’ POWER CORD 1 1 1 1

STRAIGHT-BLADE PLUG 5-20P 5-20P 5-20P 5-20P

TWIST-LOCK PLUG OPT OPT OPT OPT

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

DIMENSIONS L (INCHES) 47.5 47.5 66.25 66.25

DIMENSIONS W 1.85 1.85 1.85 1.85

DIMENSIONS D 1.3 1.3 1.3 1.3

VRTC

C140

-1027

1 2 3 4

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 24: Basic & Metered - objects.eanixter.com

27

20 Amp, 120 Volt, 1.9kW (x2)

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

LINE DRAWING 1 2 3 4 5 6

QUANTITY OF INPUTS 1 2 2 1 1 1

AMPS 20 20 x 2 20 x 2 20 20 20

VOLTS 120 120 x 2 120 x 2 120 120 120

TOTAL RECEPTACLE QTY 24 20 20 8 8 30

RECEPTACLE TYPE / QTY 5-20R / 24 5-20R / 20 5-20R / 20 C-13 / 4 C-13 / 4 C-13 / 24

RECEPTACLES PER INPUT N/A 10 10 N/A N/A N/A

RECEPTACLES PER BREAKER N/A 10 10 N/A N/A N/A

RECEPTACLE TYPE / QTY N/A N/A N/A C-19 / 4 C-19 / 4 C-19 / 6

THERMAL CIRCUIT BREAKER NO YES YES NO NO NO

BREAKER AMPERAGE / QTY N/A 20 / 2 20 / 2 N/A N/A N/A

ON-OFF SWITCH NO NO NO NO NO NO

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO NO YES x 2 * NO YES * NO

CURRENT MONITORING - LOCALAMPS NO NO OPT * NO OPT * NO

MONITORING N/A N/A CIRCUIT N/A AGGREGATE N/A

10’ POWER CORD 1 2 2 1 1 1

STRAIGHT-BLADE PLUG 5-20P (2) 5-20P (2) 5-20P 5-20P 5-20P 5-20P

TWIST-LOCK PLUG OPT OPT OPT OPT OPT OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS NO NO NO YES YES NO

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES NO NO YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75 N/A N/A 61.25 &

64.75

DIMENSIONS L (INCHES) 66.25 66.25 66.25 17 17 66.25

DIMENSIONS W 2 1.85 1.85 1.72 1.72 2

DIMENSIONS D 2 1.3 1.3 1.85 1.85 2

JBN2

42-10

2D20

ST5

JBN2

00-10

2D20

DST5

JBCN

200-1

02D2

0DST

5JL

N082

-102I4

4ST5

JLCN

082-1

02I44

ST5

JBN3

02-10

IN6S

T5

61 2 3 4 5

• UL® & c-UL® Listed 60950• Multi-input units contain color-coded receptacle confi gurations and/or labeling for easy identifi cation and load balancing* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 25: Basic & Metered - objects.eanixter.com

28

1.9kW 20 Amp, 120 Volt, Surge Suppressed

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

LINE DRAWING 1 2 3 4 5 6

AMPS 20 20 20 20 20 20

VOLTS 120 120 120 120 120 120

TOTAL RECEPTACLE QTY 8 8 10 14 20 20

RECEPTACLE TYPE / QTY 5-20R / 8 5-20R / 8 5-20R / 10 5-20R / 14 5-20R / 20 5-20R / 20

RECEPTACLES PER BREAKER 8 8 10 14 20 20

RECEPTACLE CENTER TO CENTER SPACING (INCHES) 1.25 2 2.95 2.95 2.8 2.8

RECEPTACLE ORIENTATION INLINE INLINE INLINE INLINE INLINE INLINE

THERMAL CIRCUIT BREAKER YES YES YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 1 20 / 1 20 / 1 20 / 1 20 / 1 20 / 1

ON-OFF SWITCH YES YES YES YES YES YES

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO NO NO NO NO YES *

CURRENT MONITORING - LOCALAMPS NO NO NO NO NO OPT *

MONITORING N/A N/A N/A N/A N/A AGGREGATE

10’ POWER CORD 1 1 1 1 1 1

STRAIGHT-BLADE PLUG 5-20P 5-20P 5-20P 5-20P 5-20P 5-20P

TWIST-LOCK PLUG OPT OPT OPT OPT OPT OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS YES NO NO NO NO NO

ONE BOTTOM & ONE TOP MOUNTING CLIPS YES YES YES YES NO NO

ONE BOTTOM & TWO TOP MOUNTING CLIPS NO NO NO NO YES YES

DIMENSIONS L (INCHES) 17 24 38.5 47.5 66.25 66.25

DIMENSIONS W 1.61 1.61 1.61 1.61 1.61 1.61

DIMENSIONS D 1.61 1.61 1.61 1.61 1.61 1.61

VSSL

084-1

02S2

0VS

SK08

4-102

S20

VSSA

104-1

02S2

0VS

SC14

4-102

S20

VSSB

204-1

02S2

0VS

SBC2

04-10

2S20

• UL® & c-UL® Listed 60950• Surge Suppression: 330V, 720 Joules* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Rotate Receptacle Orientation 90º: S= Inline / R= Rotated Cord Length (Feet) 02-15 (Plug Attached)

No Switch Option: Insert N before fi rst number in part number Twist-Lock Plug Option: Add TL to end of part number

Current Monitoring Option: Replace C with A in part number

61 2 3 4 5

Page 26: Basic & Metered - objects.eanixter.com

29

20 Amp, 120 Volt, Surge Suppressed, 1.9kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

• UL® & c-UL® Listed 60950• Surge Suppression: 330V, 720 Joules* Detailed meter specs available on pages 4 & 5. SV

RL06

4-102

3SV

RA10

4-102

5

LINE DRAWING 1 2 3

AMPS 20 20 20

VOLTS 120 120 120

TOTAL RECEPTACLE QTY 6 10 10

RECEPTACLE TYPE / QTY 5-20R / 6 5-20R / 10 5-20R / 10

RECEPTACLES PER BREAKER 6 10 10

THERMAL CIRCUIT BREAKER YES YES YES

BREAKER AMPERAGE / QTY 20 / 1 20 / 1 20 / 1

ON-OFF SWITCH YES YES YES

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO NO YES *

CURRENT MONITORING - LOCALAMPS NO NO OPT *

MONITORING N/A N/A AGGREGATE

10’ POWER CORD 1 1 1

STRAIGHT-BLADE PLUG 5-20P 5-20P 5-20P

TWIST-LOCK PLUG OPT OPT OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS YES NO NO

FULL-LENGTH VERTICAL MOUNTING BRACKET NO YES YES

DIMENSIONS L (INCHES) 17 38.5 38.5

DIMENSIONS W 1.72 1.85 1.85

DIMENSIONS D 1.61 1.3 1.3

SVRA

C104

-1025

1 2 3

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 27: Basic & Metered - objects.eanixter.com

30

1.9kW 20 Amp, 120 Volt, Surge Suppressed

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

LINE DRAWING 1 2 3 4

AMPS 20 20 20 20

VOLTS 120 120 120 120

TOTAL RECEPTACLE QTY 14 14 20 20

RECEPTACLE TYPE / QTY 5-20R / 14 5-20R / 14 5-20R / 20 5-20R / 20

RECEPTACLES PER BREAKER 14 14 20 20

THERMAL CIRCUIT BREAKER YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 1 20 / 1 20 / 1 20 / 1

ON-OFF SWITCH YES YES YES YES

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES *

CURRENT MONITORING - LOCALAMPS NO OPT * NO OPT *

MONITORING N/A AGGREGATE N/A AGGREGATE

10’ POWER CORD 1 1 1 1

STRAIGHT-BLADE PLUG 5-20P 5-20P 5-20P 5-20P

TWIST-LOCK PLUG OPT OPT OPT OPT

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

DIMENSIONS L (INCHES) 47.5 47.5 66.25 66.25

DIMENSIONS W 1.85 1.85 1.85 1.85

DIMENSIONS D 1.3 1.3 1.3 1.3

SVRC

144-1

027

SVRB

204-1

0210

SVRB

C204

-1021

0

SVRC

C144

-1027

1 2 3 4

• UL® & c-UL® Listed 60950• Surge Suppression: 330V, 720 Joules* Detailed meter specs available on pages 4 & 5.

ew

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 28: Basic & Metered - objects.eanixter.com

31

20 Amp, 120 or 208 Volt, 1.9kW/3.3kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

LINE DRAWING 1 2 3 4 5 6

AMPS 20 20 20 20 20 20

VOLTS 120 or 208 120 or 208 120 or 208 120 or 208 120 or 208 120 or 208

TOTAL RECEPTACLE QTY 16 16 16 16 10 10

RECEPTACLE TYPE / QTY C-13 / 16 C-13 / 16 C-13 / 16 C-13 / 16 C-13 / 10 C-13 / 10

RECEPTACLES PER BREAKER N/A N/A 16 16 N/A N/A

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD NO NO YES YES NO NO

BREAKER AMPERAGE / QTY N/A N/A 20 / 1 20 / 1 N/A N/A

BREAKER POLE CONFIGURATION N/A N/A DOUBLE DOUBLE N/A N/A

ON-OFF SWITCH NO NO BREAKER BREAKER NO NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES * NO YES *

CURRENT MONITORING - LOCALAMPS NO OPT * NO OPT * NO OPT *

MONITORING N/A AGGREGATE N/A AGGREGATE N/A AGGREGATE

IEC POWER INLET (WITH CORD RETAINING CLAMP) C-20 C-20 C-20 C-20 C-20 C-20

10’ POWER CORD NO NO NO NO NO NO

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS YES YES YES YES NO NO

HORIZONTAL & VERTICAL MOUNTING BRACKETS NO NO NO NO YES YES

DIMENSIONS L/H (INCHES) 1.72 1.72 1.72 1.72 17 17

DIMENSIONS W 17 17 17 17 1.72 1.72

DIMENSIONS D 4.5 4.5 4.5 4.5 1.61 1.61

BREN

162-0

020/1

6BR

ECN1

62-00

20/16

BRE1

60-00

20/16

IEC inlet units allow the PDU to supply 120V, 208V or 230V. The voltage distributed is determined by the voltage input. (For a complete off ering of IEC Cord Sets see page 169)

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5. BR

EC16

0-002

0/16

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part number

BREL

N102

-0020

/16BR

ELCN

102-0

020/1

6

1

2

3

4

5 6

Page 29: Basic & Metered - objects.eanixter.com

32

1.9kW/3.3kW 20 Amp, 120 or 208 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

VRTE

CN20

2-002

0/16

VRTE

CN20

0-002

0/16

VRZB

N242

-002C

13C2

0

LINE DRAWING 1 2 3 4 5

QUANTITY OF INPUTS 1 1 1 1 3

AMPS 20 20 20 20 20 x 3

VOLTS 120 or 208 120 or 208 120 or 208 120 or 208 (120 or 208) x 3

TOTAL RECEPTACLE QTY 20 20 20 20 24

RECEPTACLE TYPE / QTY C-13 / 20 C-13 / 20 C-13 / 20 C-13 / 20 C-13 / 24

RECEPTACLES PER INPUT N/A N/A N/A N/A 8

RECEPTACLES PER BREAKER PAIR N/A N/A 20 20 N/A

THERMAL CIRCUIT BREAKER NO NO YES YES NO

BREAKER AMPERAGE / QTY N/A N/A 20 / 2 20 / 2 N/A

ON-OFF SWITCH NO NO NO NO NO

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES * NO

CURRENT MONITORING - LOCALAMPS NO OPT * NO OPT * NO

MONITORING N/A AGGREGATE N/A AGGREGATE N/A

IEC POWER INLET (WITH CORD RETAINING CLAMP) C-20 C-20 C-20 C-20 C-20 x 3

10’ POWER CORD NO NO NO NO NO

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES YES

ONE BOTTOM & TWO TOP MOUNTING CLIPS OPT OPT OPT OPT NO

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25 66.25

DIMENSIONS W 1.61 1.61 1.61 1.61 2

DIMENSIONS D 1.61 1.61 1.61 1.61 1.61

VRTE

N202

-0020

/16

VRTE

N200

-0020

/16

1 2 3 4 5

IEC inlet units allow the PDU to supply 120V, 208V or 230V. The voltage distributed is determined by the voltage input. (For a complete off ering of IEC Cord Sets see page 169)

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part number

Page 30: Basic & Metered - objects.eanixter.com

33

20 Amp, 208 Volt, 3.3kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

VHVR

C120

-102D

20ST

6

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

1

2

3

4

LINE DRAWING 1 2 3 4

AMPS 20 20 20 20

VOLTS 208 208 208 208

TOTAL RECEPTACLE QTY 12 12 12 12

RECEPTACLE TYPE / QTY 6-20R / 12 6-20R / 12 6-20R / 12 6-20R / 12

RECEPTACLES PER BREAKER N/A N/A 12 12

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD NO NO YES YES

BREAKER AMPERAGE / QTY N/A N/A 20 / 1 20 / 1

BREAKER POLE CONFIGURATION N/A N/A DOUBLE DOUBLE

ON-OFF SWITCH NO NO BREAKER BREAKER

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES *

CURRENT MONITORING - LOCALAMPS NO OPT * NO OPT *

MONITORING N/A AGGREGATE N/A AGGREGATE

10’ POWER CORD 1 1 1 1

STRAIGHT-BLADE PLUG 6-20P 6-20P 6-20P 6-20P

TWIST-LOCK PLUG OPT OPT OPT OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS YES YES YES YES

DIMENSIONS H (INCHES) 1.72 1.72 1.72 1.72

DIMENSIONS W 17 17 17 17

DIMENSIONS D 6.5 6.5 6.5 6.5

VHVR

N122

-102D

20ST

6VH

VRCN

122-1

02D2

0ST6

VHVR

120-1

02D2

0ST6

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 31: Basic & Metered - objects.eanixter.com

34

3.3kW (x2) 20 Amp, 208 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5. 2V

HVRN

202-1

02D2

0DST

62V

HVRC

N202

-102D

20DS

T62V

HVR2

00-10

2D20

DST6

2VHV

RC20

0-102

D20D

ST6

LINE DRAWING 1 2 3 4

QUANTITY OF INPUTS 2 2 2 2

AMPS 20 x 2 20 x 2 20 x 2 20 x 2

VOLTS 208 x 2 208 x 2 208 x 2 208 x 2

TOTAL RECEPTACLE QTY 20 20 20 20

RECEPTACLE TYPE / QTY 6-20R / 20 6-20R / 20 6-20R / 20 6-20R / 20

RECEPTACLES PER INPUT 10 10 10 10

RECEPTACLES PER BREAKER N/A N/A 10 10

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD NO NO YES YES

BREAKER AMPERAGE / QTY N/A N/A 20 / 2 20 / 2

BREAKER POLE CONFIGURATION N/A N/A DOUBLE DOUBLE

ON-OFF SWITCH NO NO BREAKER BREAKER

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS NO YES x 2 * NO YES x 2 *

CURRENT MONITORING - LOCAL AMPS NO OPT * NO OPT *

MONITORING N/A CIRCUIT N/A CIRCUIT

10’ POWER CORD 2 2 2 2

STRAIGHT-BLADE PLUG (2) 6-20P (2) 6-20P (2) 6-20P (2) 6-20P

TWIST-LOCK PLUG OPT OPT OPT OPT

2U RECESSED MOUNTING BRACKETS YES YES YES YES

DIMENSIONS H (INCHES) 3.39 3.39 3.39 3.39

DIMENSIONS W 17 17 17 17

DIMENSIONS D 6 6 6 6

1

2

3

4

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 32: Basic & Metered - objects.eanixter.com

35

20 Amp, 208 Volt, 3.3kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

LINE DRAWING 1 2 3 4

AMPS 20 20 20 20

VOLTS 208 208 208 208

TOTAL RECEPTACLE QTY 6 6 16 16

RECEPTACLE TYPE / QTY L6-20R / 6 L6-20R / 6 C-13 / 16 C-13 / 16

CIRCUIT BREAKER / ON-OFF SWITCH NO NO NO NO

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES *

CURRENT MONITORING - LOCALAMPS NO OPT * NO OPT *

MONITORING N/A AGGREGATE N/A AGGREGATE

10’ POWER CORD 1 1 1 1

STRAIGHT-BLADE PLUG 6-20P 6-20P 6-20P 6-20P

TWIST-LOCK PLUG OPT OPT OPT OPT

2U RECESSED MOUNTING BRACKETS YES YES NO NO

FLUSH OR PANEL MOUNTING NO NO YES YES

DIMENSIONS H (INCHES) 3.39 3.39 3.45 3.45

DIMENSIONS W 17 17 17 17

DIMENSIONS D 6 6 1.61 1.61

2VHV

RN06

2-102

L20S

T62V

HVRC

N062

-102L

20ST

62V

HVLN

162-1

02C1

3ST6

2VHV

LCN1

62-10

2C13

ST6

1

2

3

4

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 33: Basic & Metered - objects.eanixter.com

36

3.3kW (x2) 20 Amp, 208 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

VHVB

N202

-102D

20ST

6VH

VBCN

202-1

02D2

0ST6

VHVB

N242

-102D

20ST

6

LINE DRAWING 1 2 3 4 5

QUANTITY OF INPUTS 1 1 1 2 2

AMPS 20 20 20 20 x 2 20 x 2

VOLTS 208 208 208 208 x 2 208 x 2

TOTAL RECEPTACLE QTY 20 20 24 20 20

RECEPTACLE TYPE / QTY 6-20R / 20 6-20R / 20 6-20R / 24 6-20R / 20 6-20R / 20

RECEPTACLES PER INPUT N/A N/A N/A 10 10

CIRCUIT BREAKER / ON-OFF SWITCH NO NO NO NO NO

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO NO YES x 2 *

CURRENT MONITORING - LOCALAMPS NO OPT * NO NO OPT *

MONITORING N/A AGGREGATE N/A N/A CIRCUIT

10’ POWER CORD 1 1 1 1 1

STRAIGHT-BLADE PLUG 6-20P 6-20P 6-20P (2) 6-20P (2) 6-20P

TWIST-LOCK PLUG OPT OPT OPT OPT OPT

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25 66.25

DIMENSIONS W 1.85 1.85 2 1.85 1.85

DIMENSIONS D 1.3 1.3 2 1.3 1.3

VHVB

N202

-102D

20DS

T6VH

VBCN

202-1

02D2

0DST

6

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

1 2 3 4 5

Page 34: Basic & Metered - objects.eanixter.com

37

20 Amp, 208 Volt, 3.3kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5. VH

VLN0

82-10

2C13

ST6

VHVL

N082

-102I4

4ST6

LINE DRAWING 1 2 3 4

AMPS 20 20 20 20

VOLTS 208 208 208 208

TOTAL RECEPTACLE QTY 8 8 8 8

RECEPTACLE TYPE / QTY C-13 / 8 C-13 / 4 C-13 / 8 C-13 / 4

RECEPTACLE TYPE / QTY N/A C-19 / 4 N/A C-19 / 4

CIRCUIT BREAKER / ON-OFF SWITCH NO NO NO NO

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO NO YES * YES *

CURRENT MONITORING - LOCALAMPS NO NO OPT * OPT *

MONITORING N/A N/A AGGREGATE AGGREGATE

10’ POWER CORD 1 1 1 1

STRAIGHT-BLADE PLUG 6-20P 6-20P 6-20P 6-20P

TWIST-LOCK PLUG OPT OPT OPT OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS YES YES YES YES

DIMENSIONS L (INCHES) 17 17 17 17

DIMENSIONS W 1.72 1.72 1.72 1.72

DIMENSIONS D 1.61 1.85 1.61 1.85

VHVL

CN08

2-102

C13S

T6VH

VLCN

082-1

02I44

ST6

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

1 2 3 4

Page 35: Basic & Metered - objects.eanixter.com

38

3.3kW 20 Amp, 208 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

VHVB

N242

-102C

13ST

6VH

VBCN

242-1

02C1

3ST6

VHVB

N302

-102IN

6ST6

VHVL

N102

-102C

13ST

6VH

VLCN

102-1

02C1

3ST6

1 2 3 4 5LINE DRAWING 1 2 3 4 5

AMPS 20 20 20 20 20

VOLTS 208 208 208 208 208

TOTAL RECEPTACLE QTY 10 10 24 24 30

RECEPTACLE TYPE / QTY C-13 / 10 C-13 / 10 C-13 / 24 C-13 / 24 C-13 / 24

RECEPTACLE TYPE / QTY N/A N/A N/A N/A C-19 / 6

CIRCUIT BREAKER / ON-OFF SWITCH NO NO NO NO NO

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES * NO

CURRENT MONITORING - LOCALAMPS NO OPT * NO OPT * NO

MONITORING N/A AGGREGATE N/A AGGREGATE N/A

10’ POWER CORD 1 1 1 1 1

STRAIGHT-BLADE PLUG 6-20P 6-20P 6-20P 6-20P 6-20P

TWIST-LOCK PLUG OPT OPT OPT OPT OPT

HORIZONTAL / PANEL MOUNTING BRACKETS YES YES N/A N/A N/A

FULL-LENGTH VERTICAL MOUNTING BRACKET N/A N/A YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES) N/A N/A 61.25 &

64.7561.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES) 17 17 66.25 66.25 66.25

DIMENSIONS W 1.72 1.72 1.72 1.72 2

DIMENSIONS D 1.61 1.61 1.61 1.61 2

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part number

Cord Length (Feet) 02-15 (Plug Attached)

Twist-Lock Plug Option: Add TL to end of part number

Page 36: Basic & Metered - objects.eanixter.com

39

20 Amp, 3 Phase, 5.8kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

1 2 3 4

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5. JB

N243

-102D

20TL

21JB

AN24

3-102

D20T

L21

LINE DRAWING 1 2 3 4

AMPS 20 x 3~ 20 x 3~ 20 x 3~ 20 x 3~

VOLTS 120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS 120 120 120 120

TOTAL RECEPTACLE QTY 24 24 12 12

RECEPTACLE TYPE / QTY 5-20R / 24 5-20R / 24 L5-20R / 12 L5-20R / 12

RECEPTACLES PER PHASE 8 8 4 4

CIRCUIT BREAKER / ON-OFF SWITCH NO NO NO NO

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING NO YES * NO YES *

MONITORING N/A PHASE (X,Y,Z) N/A PHASE

(X,Y,Z)

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L21-20P L21-20P L21-20P L21-20P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25

DIMENSIONS W 2 2 2 2

DIMENSIONS D 2 2 2 2

JBN1

23-10

2L20

TL21

JBAN

123-1

02L2

0TL2

1

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

Page 37: Basic & Metered - objects.eanixter.com

40

5.8kW 20 Amp, 3 Phase

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

JBN3

03-10

2IN6T

L21

JBAN

303-1

02IN

6TL2

1

LINE DRAWING 1 2

AMPS 20 x 3~ 20 x 3~

VOLTS 120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS 120 120

TOTAL RECEPTACLE QTY 30 30

RECEPTACLE TYPE / QTY C-13 / 24 C-13 / 24

RECEPTACLES PER PHASE 8 8

RECEPTACLE TYPE / QTY C-19 / 6 C-19 / 6

RECEPTACLES PER PHASE 2 2

CIRCUIT BREAKER / ON-OFF SWITCH NO NO

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING NO YES *

MONITORING N/A PHASE (X,Y,Z)

10’ POWER CORD 1 1

TWIST-LOCK PLUG L21-20P L21-20P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES) 66.25 66.25

DIMENSIONS W 2 2

DIMENSIONS D 2 2

1 2

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

Page 38: Basic & Metered - objects.eanixter.com

41

20 Amp, 3 Phase, 5.8kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

1 2 3 4VH

VBN2

48-10

2D20

TL21

VHVB

AN24

8-102

D20T

L21

LINE DRAWING 1 2 3 4

AMPS 20 x 3~ 20 x 3~ 20 x 3~ 20 x 3~

VOLTS 120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS 208 208 208 208

TOTAL RECEPTACLE QTY 24 24 12 12

RECEPTACLE TYPE / QTY 6-20R / 24 6-20R / 24 L6-20R / 12 L6-20R / 12

RECEPTACLES PER PHASE COMBINATION 8 8 4 4

CIRCUIT BREAKER / ON-OFF SWITCH NO NO NO NO

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING NO YES * NO YES *

MONITORING N/A CIRCUIT (XY,YZ,ZX) N/A CIRCUIT

(XY,YZ,ZX)

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L21-20P L21-20P L21-20P L21-20P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25

DIMENSIONS W 2 2 2 2

DIMENSIONS D 2 2 2 2

VHVB

N128

-102L

20TL

21VH

VBAN

128-1

02L2

0TL2

1

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

Page 39: Basic & Metered - objects.eanixter.com

42

5.8kW 20 Amp, 3 Phase

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

VHVB

N248

-102C

13TL

21VH

VBAN

248-1

02C1

3TL2

1VH

VBN3

08-10

2IN6T

L21

VHVB

AN30

8-102

IN6T

L21

LINE DRAWING 1 2 3 4

AMPS 20 x 3~ 20 x 3~ 20 x 3~ 20 x 3~

VOLTS 120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS 208 208 208 208

TOTAL RECEPTACLE QTY 24 24 30 30

RECEPTACLE TYPE / QTY C-13 / 24 C-13 / 24 C-13 / 24 C-13 / 24

RECEPTACLES PER PHASE COMBINATION 8 8 8 8

RECEPTACLE TYPE / QTY N/A N/A C-19 / 6 C-19 / 6

RECEPTACLES PER PHASE COMBINATION N/A N/A 2 2

CIRCUIT BREAKER / ON-OFF SWITCH NO NO NO NO

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING NO YES * NO YES *

MONITORING N/A CIRCUIT (XY,YZ,ZX) N/A CIRCUIT

(XY,YZ,ZX)

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L21-20P L21-20P L21-20P L21-20P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25

DIMENSIONS W 1.72 1.72 2 2

DIMENSIONS D 1.61 1.61 2 2

1 2 3 4

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

Page 40: Basic & Metered - objects.eanixter.com

43

20 Amp, 3 Phase, 5.8kW (x2)

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

2VHV

BN48

8-102

C13D

TL21

2VHV

BAN4

88-10

2C13

DTL2

1VH

VBN3

09-10

2M11

TL21

VHVB

AN30

9-102

M11T

L21

VHVW

N189

-102M

12TL

21

LINE DRAWING 1 2 3 4 5

QUANTITY OF INPUTS 2 2 1 1 1

AMPS (20 x 3~) x 2 (20 x 3~) x 2 20 x 3~ 20 x 3~ 20 x 3~

VOLTS (120 / 208 WYE) x 2

(120 / 208 WYE) x 2

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS 208 208 120 & 208 120 & 208 120 & 208

TOTAL RECEPTACLE QTY 48 48 30 30 18

RECEPTACLE TYPE / QTY C-13 / 48 C-13 / 48 L6-20R / 6 L6-20R / 6 C-13 / 12

RECEPTACLES PER INPUT 24 24 N/A N/A N/A

RECEPTACLES PER PHASE COMBINATION PER INPUT 8 8 2 2 4

RECEPTACLE TYPE / QTY N/A N/A 5-20R / 24 5-20R / 24 5-20R / 6

RECEPTACLES PER PHASE N/A N/A 8 8 2

CIRCUIT BREAKER / ON-OFF SWITCH NO NO NO NO NO

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING NO YES x 2 * NO YES * NO

MONITORING N/A CIRCUIT (XY,YZ,ZX) N/A CIRCUIT

(XY,YZ,ZX) N/A

10’ POWER CORD 2 2 1 1 1

TWIST-LOCK PLUG (2) L21-20P (2) L21-20P L21-20P L21-20P L21-20P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25 70

DIMENSIONS W 3.5 3.5 2 2 2

DIMENSIONS D 2 2 2 2 2

1 2 3 4 5

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

Page 41: Basic & Metered - objects.eanixter.com

44

11kW 20 Amp, 3 Phase

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

YBN3

03-10

2IN6T

L22

YBAN

303-1

02IN

6TL2

2

LINE DRAWING 1 2 3 4

QUANTITY OF INPUTS 1 1 1 1

AMPS 20 x 3~ 20 x 3~ 20 x 3~ 20 x 3~

VOLTS 230 / 400 WYE

230 / 400 WYE

230 / 400 WYE

230 / 400 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS 230 230 230 230

TOTAL RECEPTACLE QTY 30 30 30 30

RECEPTACLE TYPE / QTY C-13 / 24 C-13 / 24 C-13 / 24 C-13 / 24

RECEPTACLES PER PHASE 8 8 8 8

RECEPTACLE TYPE / QTY C-19 / 6 C-19 / 6 C-19 / 6 C-19 / 6

RECEPTACLES PER PHASE 2 2 2 2

CIRCUIT BREAKER / ON-OFF SWITCH NO NO NO NO

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING NO YES * NO YES *

MONITORING N/A PHASE (X,Y,Z) N/A PHASE

(X,Y,Z)

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L22-20P L22-20P N/A N/A

IEC 60309 PIN & SLEEVE CONNECTOR N/A N/A20A,

230 / 400V, 4P / 5W

20A, 230 / 400V,

4P / 5W

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25

DIMENSIONS W 2 2 2 2

DIMENSIONS D 2 2 2 2

1 2

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

3 4

YBN3

03-10

2IN6P

S56

YBAN

303-1

02IN

6PS5

6

ew 230/400Vew 230/400V

ew 230/400Vew 230/400V

Page 42: Basic & Metered - objects.eanixter.com

45

30 Amp, 120 Volt, 2.9kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & Metered

BRDN

080-1

034T

LBR

DCN0

80-10

34TL

BRD1

20-10

36TL

XPRC

120-1

03D2

0TL5

XPR1

20-10

3D20

TL5

LINE DRAWING 1 2 3 4 5

AMPS 30 30 30 30 30

VOLTS 120 120 120 120 120

UL® & c-UL® Listed 60950 NO NO NO YES YES

UL® & c-UL® Listed 1950 YES YES YES NO NO

TOTAL RECEPTACLE QTY 8 8 12 12 12

RECEPTACLE TYPE / QTY 5-20R / 8 5-20R / 8 5-20R / 12 5-20R / 12 5-20R / 12

RECEPTACLES PER BREAKER 4 4 6 6 6

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD NO NO NO YES YES

THERMAL CIRCUIT BREAKER YES YES YES NO NO

BREAKER AMPERAGE / QTY 15 / 2 15 / 2 15 / 2 20 / 2 20 / 2

BREAKER POLE CONFIGURATION SINGLE SINGLE SINGLE SINGLE SINGLE

ON-OFF SWITCH NO NO YES BREAKER BREAKER

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO NO YES *

MONITORING N/A AGGREGATE N/A N/A AGGREGATE

CURRENT MONITORING - LOCAL AMPS - AGGREGATE NO OPT * NO NO OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO OPT * NO NO OPT *

10’ POWER CORD 1 1 1 1 1

TWIST-LOCK PLUG L5-30P L5-30P L5-30P L5-30P L5-30P

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS OPT OPT YES YES YES

FLUSH MOUNTING YES YES NO NO NO

DIMENSIONS H (INCHES) 1.72 1.72 1.72 1.72 1.72

DIMENSIONS W 17 17 17 17 17

DIMENSIONS D 4.5 4.5 4.5 6.5 6.5

• UL® & c-UL® Listed (see chart for details)* Detailed meter specs available on pages 4 & 5.

1

2

3

4

5

SatelliteMonitored

Basic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

A

T

MODIFY TO MEET YOUR NEEDS

No Switch Option: Insert N before fi rst number in part number

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 43: Basic & Metered - objects.eanixter.com

46

2.9kW 30 Amp, 120 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5. 2X

PR20

0-103

D20T

L52X

PRC2

00-10

3D20

TL5

2XPR

N062

-103L

30TL

52X

PRCN

062-1

03L3

0TL5

2XPR

060-1

03L2

0TL5

LINE DRAWING 1 2 3 4 5 6

AMPS 30 30 30 30 30 30

VOLTS 120 120 120 120 120 120

TOTAL RECEPTACLE QTY 20 20 6 6 6 6

RECEPTACLE TYPE / QTY 5-20R / 20 5-20R / 20 L5-30R / 6 L5-30R / 6 L5-20R / 6 L5-20R / 6

RECEPTACLES PER BREAKER 10 10 N/A N/A 3 3

MAGNETIC CIRCUIT BREAKER / ON-OFFSWITCH WITH INTEGRAL GUARD YES YES NO NO YES YES

BREAKER AMPERAGE / QTY 20 / 2 20 / 2 N/A N/A 20 / 2 20 / 2

BREAKER POLE CONFIGURATION SINGLE SINGLE N/A N/A SINGLE SINGLE

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES * NO YES *

MONITORING N/A AGGREGATE N/A AGGREGATE N/A AGGREGATE

CURRENT MONITORING - LOCAL AMPS - AGGREGATE NO OPT * NO OPT * NO OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO OPT * NO OPT * NO OPT *

10’ POWER CORD 1 1 1 1 1 1

TWIST-LOCK PLUG L5-30P L5-30P L5-30P L5-30P L5-30P L5-30P

2U RECESSED MOUNTING BRACKETS YES YES YES YES YES YES

DIMENSIONS H (INCHES) 3.39 3.39 3.39 3.39 3.39 3.39

DIMENSIONS W 17 17 17 17 17 17

DIMENSIONS D 6 6 6 6 6 6

2XPR

C060

-103L

20TL

5

1

2

3

4

5

6

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 44: Basic & Metered - objects.eanixter.com

47

30 Amp, 120 Volt, 2.9kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

XPRC

120-1

03C1

3TL5

2VRE

LN16

0-103

C13T

L52V

RELC

N160

-103C

13TL

5

• UL® & c-UL® Listed (see chart for details)* Detailed meter specs available on pages 4 & 5. XP

R120

-103C

13TL

5

LINE DRAWING 1 2 3 4

AMPS 30 30 30 30

VOLTS 120 120 120 120

UL® & c-UL® Listed 60950 YES YES NO NO

UL® & c-UL® Listed 1950 NO NO YES YES

TOTAL RECEPTACLE QTY 12 12 16 16

RECEPTACLE TYPE / QTY C-13 / 12 C-13 / 12 C-13 / 16 C-13 / 16

RECEPTACLES PER BREAKER 6 6 8 8

MAGNETIC CIRCUIT BREAKER / ON-OFFSWITCH WITH INTEGRAL GUARD YES YES NO NO

THERMAL CIRCUIT BREAKER NO NO YES YES

BREAKER AMPERAGE / QTY 20 / 2 20 / 2 15 / 2 15 / 2

BREAKER POLE CONFIGURATION SINGLE SINGLE SINGLE SINGLE

ON-OFF SWITCH BREAKER BREAKER NO NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES *

MONITORING N/A AGGREGATE N/A AGGREGATE

CURRENT MONITORING - LOCAL AMPS - AGGREGATE NO OPT * NO OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO OPT * NO OPT *

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L5-30P L5-30P L5-30P L5-30P

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS YES YES NO NO

FLUSH OR PANEL MOUNTING NO NO YES YES

DIMENSIONS H (INCHES) 1.72 1.72 3.45 3.45

DIMENSIONS W 17 17 17 17

DIMENSIONS D 6.5 6.5 1.61 1.61

1

2

3

4

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 45: Basic & Metered - objects.eanixter.com

48

2.9kW 30 Amp, 120 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

LINE DRAWING 1 2

AMPS 30 30

VOLTS 120 120

TOTAL RECEPTACLE QTY 20 20

RECEPTACLE TYPE / QTY 5-20R / 20 5-20R / 20

RECEPTACLES PER BREAKER 10 10

THERMAL CIRCUIT BREAKER YES YES

BREAKER AMPERAGE / QTY 15 / 2 15 / 2

BREAKER POLE CONFIGURATION SINGLE SINGLE

ON-OFF SWITCH NO NO

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES *

MONITORING N/A AGGREGATE

CURRENT MONITORING - LOCALAMPS - AGGREGATE NO OPT *

CURRENT MONITORING - LOCALAMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO OPT *

10’ POWER CORD 1 1

TWIST-LOCK PLUG L5-30P L5-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES) 66.25 66.25

DIMENSIONS W 1.85 1.85

DIMENSIONS D 1.3 1.3

VRTD

N200

-1031

0TL

VRTD

CN20

0-103

10TL

1 2

• UL® & c-UL® Listed 1950* Detailed meter specs available on pages 4 & 5.

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 46: Basic & Metered - objects.eanixter.com

49

30 Amp, 120 Volt, 2.9kW (x2)

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

XPB2

40-10

3D20

DTL5

XPBC

240-1

03D2

0DTL

5

XPB2

40-10

3D20

TL5

XPBC

240-1

03D2

0TL5

LINE DRAWING 1 2 3 4

QUANTITY OF INPUTS 1 1 2 2

AMPS 30 30 30 x 2 30 x 2

VOLTS 120 120 120 x 2 120 x 2

TOTAL RECEPTACLE QTY 24 24 24 24

RECEPTACLE TYPE / QTY 5-20R / 24 5-20R / 24 5-20R / 24 5-20R / 24

RECEPTACLES PER INPUT N/A N/A 12 12

RECEPTACLES PER BREAKER 12 12 6 PER POLE

6 PER POLE

MAGNETIC CIRCUIT BREAKER / ON-OFFSWITCH WITH INTEGRAL GUARD YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 2 20 / 2 20 / 2 20 / 2

BREAKER POLE CONFIGURATION SINGLE SINGLE DOUBLE DOUBLE

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES x 2 *

MONITORING N/A AGGREGATE N/A CIRCUIT

CURRENT MONITORING - LOCALAMPS - AGGREGATE NO OPT * NO OPT *

CURRENT MONITORING - LOCALAMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO OPT * NO OPT *

10’ POWER CORD 1 1 2 2

TWIST-LOCK PLUG L5-30P L5-30P (2) L5-30P (2) L5-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH YES YES YES YES

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25

DIMENSIONS W 2 2 2 2

DIMENSIONS D 2 2 2 2

1 2 3 4

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 47: Basic & Metered - objects.eanixter.com

50

2.9kW 30 Amp, 120 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

VREL

N080

-103C

13TL

5VR

ELN0

80-10

3I44T

L5VR

ELCN

080-1

03C1

3TL5

VREL

CN08

0-103

I44TL

5

LINE DRAWING 1 2 3 4

AMPS 30 30 30 30

VOLTS 120 120 120 120

TOTAL RECEPTACLE QTY 8 8 8 8

RECEPTACLE TYPE / QTY C-13 / 8 C-13 / 4 C-13 / 8 C-13 / 4

RECEPTACLES PER BREAKER 4 2 4 2

RECEPTACLE TYPE / QTY N/A C-19 / 4 N/A C-19 / 4

RECEPTACLES PER BREAKER N/A 2 N/A 2

THERMAL CIRCUIT BREAKER YES YES YES YES

BREAKER AMPERAGE / QTY 15 / 2 15 / 2 15 / 2 15 / 2

BREAKER POLE CONFIGURATION SINGLE SINGLE SINGLE SINGLE

ON-OFF SWITCH NO NO NO NO

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO NO YES * YES *

MONITORING N/A N/A AGGREGATE AGGREGATE

CURRENT MONITORING - LOCALAMPS - AGGREGATE NO NO OPT * OPT *

CURRENT MONITORING - LOCALAMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO NO OPT * OPT *

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L5-30P L5-30P L5-30P L5-30P

HORIZONTAL & VERTICAL MOUNTING BRACKETS YES YES YES YES

DIMENSIONS L (INCHES) 17 17 17 17

DIMENSIONS W 1.72 1.72 1.72 1.72

• UL® & c-UL® Listed 1950* Detailed meter specs available on pages 4 & 5.

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

1 2 3 4

Page 48: Basic & Metered - objects.eanixter.com

51

30 Amp, 120 Volt, 2.9kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

VREL

N100

-103C

13TL

5VR

ELCN

100-1

03C1

3TL5

VREB

N240

-103C

13TL

5VR

EBCN

240-1

03C1

3TL5

1 2 3 4LINE DRAWING 1 2 3 4

AMPS 30 30 30 30

VOLTS 120 120 120 120

TOTAL RECEPTACLE QTY 10 10 24 24

RECEPTACLE TYPE / QTY C-13 / 10 C-13 / 10 C-13 / 24 C-13 / 24

RECEPTACLES PER BREAKER 5 5 12 12

THERMAL CIRCUIT BREAKER YES YES YES YES

BREAKER AMPERAGE / QTY 15 / 2 15 / 2 15 / 2 15 / 2

BREAKER POLE CONFIGURATION SINGLE SINGLE SINGLE SINGLE

ON-OFF SWITCH NO NO NO NO

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES *

MONITORING N/A AGGREGATE N/A AGGREGATE

CURRENT MONITORING - LOCALAMPS - AGGREGATE NO OPT * NO OPT *

CURRENT MONITORING - LOCALAMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO OPT * NO OPT *

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L5-30P L5-30P L5-30P L5-30P

HORIZONTAL & VERTICAL MOUNTING BRACKETS YES YES NO NO

FULL-LENGTH VERTICAL MOUNTING BRACKET NO NO YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES) N/A N/A 61.25 &

64.7561.25 & 64.75

DIMENSIONS L (INCHES) 17 17 66.25 66.25

DIMENSIONS W 1.72 1.72 1.72 1.72

DIMENSIONS D 1.61 1.61 1.72 1.72

• UL® & c-UL® Listed 1950* Detailed meter specs available on pages 4 & 5.

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 49: Basic & Metered - objects.eanixter.com

52

2.9kW (x2) 30 Amp, 120 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

2XPB

480-1

03C1

3DTL

52X

PBC4

80-10

3C13

DTL5

XPB3

00-10

3IN6T

L5

LINE DRAWING 1 2 3 4

QUANTITY OF INPUTS 1 1 2 2

AMPS 30 30 30 x 2 30 x 2

VOLTS 120 120 120 x 2 120 x 2

TOTAL RECEPTACLE QTY 30 30 48 48

RECEPTACLE TYPE / QTY C-13 / 24 C-13 / 24 C-13 / 48 C-13 / 48

RECEPTACLES PER INPUT N/A N/A 24 24

RECEPTACLES PER BREAKER 12 12 12 12

RECEPTACLE TYPE / QTY C-19 / 6 C-19 / 6 N/A N/A

RECEPTACLES PER BREAKER 3 3 N/A N/A

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 2 20 / 2 20 / 4 20 / 4

BREAKER POLE CONFIGURATION SINGLE SINGLE SINGLE SINGLE

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES x 2 *

MONITORING N/A AGGREGATE N/A CIRCUIT

CURRENT MONITORING - LOCAL AMPS - AGGREGATE NO OPT * NO OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO OPT * NO OPT *

10’ POWER CORD 1 1 2 2

TWIST-LOCK PLUG L5-30P L5-30P (2) L5-30P (2) L5-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH YES YES YES YES

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25

DIMENSIONS W 2 2 3.5 3.5

DIMENSIONS D 2 2 2 2

XPBC

300-1

03IN

6TL5

1 2 3 4

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 50: Basic & Metered - objects.eanixter.com

53

30 Amp, 208 Volt, 5kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

2XPR

C200

-103D

20TL

6

XPR1

20-10

3D20

TL6

XPRC

120-1

03D2

0TL6

2XPR

200-1

03D2

0TL6

LINE DRAWING 1 2 3 4

AMPS 30 30 30 30

VOLTS 208 208 208 208

TOTAL RECEPTACLE QTY 12 12 20 20

RECEPTACLE TYPE / QTY 6-20R / 12 6-20R / 12 6-20R / 20 6-20R / 20

RECEPTACLES PER BREAKER 6 6 10 10

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 2 20 / 2 20 / 2 20 / 2

BREAKER POLE CONFIGURATION DOUBLE DOUBLE DOUBLE DOUBLE

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES *

MONITORING N/A AGGREGATE N/A AGGREGATE

CURRENT MONITORING - LOCALAMPS - AGGREGATE NO OPT * NO OPT *

CURRENT MONITORING - LOCALAMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO OPT * NO OPT *

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L6-30P L6-30P L6-30P L6-30P

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS YES YES NO NO

2U RECESSED MOUNTING BRACKETS NO NO YES YES

DIMENSIONS H (INCHES) 1.72 1.72 3.39 3.39

DIMENSIONS W 17 17 17 17

DIMENSIONS D 6.5 6.5 6 6

1

2

3

4

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 51: Basic & Metered - objects.eanixter.com

54

5kW 30 Amp, 208 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

2XPR

N062

-103L

30TL

62X

PRCN

062-1

03L3

0TL6

2XPR

060-1

03L2

0TL6

2XPR

C060

-103L

20TL

6

LINE DRAWING 1 2 3 4

AMPS 30 30 30 30

VOLTS 208 208 208 208

TOTAL RECEPTACLE QTY 6 6 6 6

RECEPTACLE TYPE / QTY L6-30R / 6 L6-30R / 6 L6-20R / 6 L6-20R / 6

RECEPTACLES PER BREAKER N/A N/A 3 3

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD NO NO YES YES

BREAKER AMPERAGE / QTY N/A N/A 20 / 2 20 / 2

BREAKER POLE CONFIGURATION N/A N/A DOUBLE DOUBLE

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES *

MONITORING N/A AGGREGATE N/A AGGREGATE

CURRENT MONITORING - LOCALAMPS - AGGREGATE NO OPT * NO OPT *

CURRENT MONITORING - LOCALAMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO OPT * NO OPT *

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L6-30P L6-30P L6-30P L6-30P

2U RECESSED MOUNTING BRACKETS YES YES YES YES

DIMENSIONS H (INCHES) 3.39 3.39 3.39 3.39

DIMENSIONS W 17 17 17 17

DIMENSIONS D 6 6 6 6

1

2

3

4

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 52: Basic & Metered - objects.eanixter.com

55

30 Amp, 208 Volt, 5kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

XPR1

20-10

3C13

TL6

XPRC

120-1

03C1

3TL6

2VRE

LCN1

60-10

3C13

TL6

2VRE

LN16

0-103

C13T

L6

LINE DRAWING 1 2 3 4

AMPS 30 30 30 30

VOLTS 208 208 208 208

UL® & c-UL® Listed 60950 YES YES NO NO

UL® & c-UL® Listed 1950 NO NO YES YES

TOTAL RECEPTACLE QTY 12 12 16 16

RECEPTACLE TYPE / QTY C-13 / 12 C-13 / 12 C-13 / 16 C-13 / 16

RECEPTACLES PER BREAKER 6 6 N/A N/A

RECEPTACLES PER BREAKER PAIR N/A N/A 8 8

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD YES YES NO NO

THERMAL CIRCUIT BREAKER NO NO YES YES

BREAKER AMPERAGE / QTY 20 / 2 20 / 2 15 / 4 15 / 4

BREAKER POLE CONFIGURATION DOUBLE DOUBLE SINGLE SINGLE

ON-OFF SWITCH BREAKER BREAKER NO NO

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES *

MONITORING N/A AGGREGATE N/A AGGREGATE

CURRENT MONITORING - LOCALAMPS - AGGREGATE NO OPT * NO OPT *

CURRENT MONITORING - LOCALAMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO OPT * NO OPT *

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L6-30P L6-30P L6-30P L6-30P

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS YES YES NO NO

FLUSH OR PANEL MOUNTING NO NO YES YES

DIMENSIONS H (INCHES) 1.72 1.72 3.45 3.45

DIMENSIONS W 17 17 17 17

DIMENSIONS D 6.5 6.5 1.61 1.61

• UL® & c-UL® Listed (see chart for details)* Detailed meter specs available on pages 4 & 5.

1

2

3

4

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 53: Basic & Metered - objects.eanixter.com

56

5kW 30 Amp, 208 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

• UL® & c-UL® Listed (see chart for details)* Detailed meter specs available on pages 4 & 5. VR

EBN2

00-10

3D20

TL6

VREB

CN20

0-103

D20T

L6XP

B240

-103D

20TL

6XP

BC24

0-103

D20T

L6

1 2 3 4 5 6

XPB1

20-10

3L20

TL6

XPBC

120-1

03L2

0TL6

LINE DRAWING 1 2 3 4 5 6

AMPS 30 30 30 30 30 30

VOLTS 208 208 208 208 208 208

UL® & c-UL® Listed 60950 NO NO YES YES YES YES

UL® & c-UL® Listed 1950 YES YES NO NO NO NO

TOTAL RECEPTACLE QTY 20 20 24 24 12 12

RECEPTACLE TYPE / QTY 6-20R / 20 6-20R / 20 6-20R / 24 6-20R / 24 L6-20R / 12 L6-20R / 12

RECEPTACLES PER BREAKER N/A N/A 12 12 6 6

RECEPTACLES PER BREAKER PAIR 10 10 N/A N/A N/A N/A

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD NO NO YES YES YES YES

THERMAL CIRCUIT BREAKER YES YES NO NO NO NO

BREAKER AMPERAGE / QTY 15 / 4 15 / 4 20 / 2 20 / 2 20 / 2 20 / 2

BREAKER POLE CONFIGURATION SINGLE SINGLE DOUBLE DOUBLE DOUBLE DOUBLE

ON-OFF SWITCH NO NO BREAKER BREAKER BREAKER BREAKER

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES * NO YES *

MONITORING N/A AGGREGATE N/A AGGREGATE N/A AGGREGATE

CURRENT MONITORING - LOCAL AMPS - AGGREGATE NO OPT * NO OPT * NO OPT *

CURRENT MONITORING - LOCALAMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO OPT * NO OPT * NO OPT *

10’ POWER CORD 1 1 1 1 1 1

TWIST-LOCK PLUG L6-30P L6-30P L6-30P L6-30P L6-30P L6-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH NO NO YES YES YES YES

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25 66.25 66.25

DIMENSIONS W 1.85 1.85 2 2 2 2

DIMENSIONS D 1.61 1.61 2 2 2 2

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 54: Basic & Metered - objects.eanixter.com

57

30 Amp, 208 Volt, 5kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

VREL

N080

-103C

13TL

6VR

ELN0

80-10

3I44T

L6VR

ELCN

080-1

03C1

3TL6

LINE DRAWING 1 2 3 4

AMPS 30 30 30 30

VOLTS 208 208 208 208

TOTAL RECEPTACLE QTY 8 8 8 8

RECEPTACLE TYPE / QTY C-13 / 8 C-13 / 4 C-13 / 8 C-13 / 4

RECEPTACLES PER BREAKER PAIR 4 2 4 2

RECEPTACLE TYPE / QTY N/A C-19 / 4 N/A C-19 / 4

RECEPTACLES PER BREAKER PAIR N/A 2 N/A 2

THERMAL CIRCUIT BREAKER YES YES YES YES

BREAKER AMPERAGE / QTY 15 / 4 15 / 4 15 /4 15 /4

BREAKER POLE CONFIGURATION SINGLE SINGLE SINGLE SINGLE

ON-OFF SWITCH NO NO NO NO

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO NO YES * YES *

MONITORING N/A N/A AGGREGATE AGGREGATE

CURRENT MONITORING - LOCALAMPS - AGGREGATE NO NO OPT * OPT *

CURRENT MONITORING - LOCALAMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO NO OPT * OPT *

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L6-30P L6-30P L6-30P L6-30P

HORIZONTAL & VERTICAL MOUNTING BRACKETS YES YES YES YES

DIMENSIONS L (INCHES) 17 17 17 17

DIMENSIONS W 1.72 1.72 1.72 1.72

DIMENSIONS D 1.61 1.85 1.61 1.85

VREL

CN08

0-103

I44TL

6

1 2 3 4

• UL® & c-UL® Listed 1950* Detailed meter specs available on pages 4 & 5.

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 55: Basic & Metered - objects.eanixter.com

58

5kW 30 Amp, 208 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

• UL® & c-UL® Listed 1950* Detailed meter specs available on pages 4 & 5. VR

ELN1

00-10

3C13

TL6

VREL

CN10

0-103

C13T

L6

1 2 3 4

VREB

N240

-103C

13TL

6VR

EBCN

240-1

03C1

3TL6

LINE DRAWING 1 2 3 4

AMPS 30 30 30 30

VOLTS 208 208 208 208

TOTAL RECEPTACLE QTY 10 10 24 24

RECEPTACLE TYPE / QTY C-13 / 10 C-13 / 10 C-13 / 24 C-13 / 24

RECEPTACLES PER BREAKER PAIR 5 5 12 12

THERMAL CIRCUIT BREAKER YES YES YES YES

BREAKER AMPERAGE / QTY 15 / 4 15 / 4 15 / 4 15 / 4

BREAKER POLE CONFIGURATION SINGLE SINGLE SINGLE SINGLE

ON-OFF SWITCH NO NO NO NO

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES *

MONITORING N/A AGGREGATE N/A AGGREGATE

CURRENT MONITORING - LOCAL AMPS - AGGREGATE NO OPT * NO OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO OPT * NO OPT *

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L6-30P L6-30P L6-30P L6-30P

HORIZONTAL & VERTICAL MOUNTING BRACKETS YES YES NO NO

FULL-LENGTH VERTICAL MOUNTING BRACKET NO NO YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES) NO NO 61.25 &

64.7561.25 & 64.75

DIMENSIONS L (INCHES) 17 17 66.25 66.25

DIMENSIONS W 1.72 1.72 1.72 1.72

DIMENSIONS D 1.61 1.61 1.72 1.72

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 56: Basic & Metered - objects.eanixter.com

59

30 Amp, 208 Volt, 5kW (x2)

8 0 0 - 4 3 2 - 3 2 1 9

Basic & Metered

1 2 3 4XP

B300

-103IN

6TL6

XPBC

300-1

03IN

6TL6

2XPB

480-1

03C1

3DTL

62X

PBC4

80-10

3C13

DTL6

LINE DRAWING 1 2 3 4

QUANTITY OF INPUTS 1 1 2 2

AMPS 30 30 30 x 2 30 x 2

VOLTS 208 208 208 x 2 208 x 2

TOTAL RECEPTACLE QTY 30 30 48 48

RECEPTACLE TYPE / QTY C-13 / 24 C-13 / 24 C-13 / 48 C-13 / 48

RECEPTACLES PER INPUT N/A N/A 24 24

RECEPTACLES PER BREAKER 12 12 12 12

RECEPTACLE TYPE / QTY C-19 / 6 C-19 / 6 N/A N/A

RECEPTACLES PER BREAKER 3 3 N/A N/A

MAGNETIC CIRCUIT BREAKER / ON-OFF YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 2 20 / 2 20 / 4 20 / 4

BREAKER POLE CONFIGURATION DOUBLE DOUBLE DOUBLE DOUBLE

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS NO YES * NO YES x 2 *

MONITORING N/A AGGREGATE N/A AGGREGATE

CURRENT MONITORING - LOCAL AMPS - AGGREGATE NO OPT * NO OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL NO OPT * NO OPT *

10’ POWER CORD 1 1 2 2

TWIST-LOCK PLUG L6-30P L6-30P (2) L6-30P (2) L6-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH YES YES YES YES

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25

DIMENSIONS W 2 2 3.5 3.5

DIMENSIONS D 2 2 2 2

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

SatelliteMonitored

Basic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

A

T

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part numberCurrent Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Cord Length (Feet) 02-15 (Plug Attached)

AT

Page 57: Basic & Metered - objects.eanixter.com

60

8.6kW 30 Amp, 3 Phase

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

1 2 3 4

XPB1

23-10

3L20

TL21

XPBA

123-1

03L2

0TL2

1

LINE DRAWING 1 2 3 4

AMPS 30 x 3~ 30 x 3~ 30 x 3~ 30 x 3~

VOLTS 120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS 120 120 120 120

TOTAL RECEPTACLE QTY 24 24 12 12

RECEPTACLE TYPE / QTY 5-20R / 24 5-20R / 24 L5-20R / 12 L5-20R / 12

RECEPTACLES PER BREAKER AND PHASE 8 8 4 4

MAGNETIC CIRCUIT BREAKER / ON-OFFSWITCH WITH INTEGRAL GUARD YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 3 20 / 3 20 / 3 20 / 3

BREAKER POLE CONFIGURATION DOUBLE DOUBLE DOUBLE DOUBLE

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING NO YES * NO YES *

MONITORING N/APHASE/

BREAKER(X,Y,Z)

N/APHASE/

BREAKER(X,Y,Z)

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L21-30P L21-30P L21-30P L21-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH YES YES YES YES

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25

DIMENSIONS W 2 2 2 2

DIMENSIONS D 2 2 2 2

XPB2

43-10

3D20

TL21

XPBA

243-1

03D2

0TL2

1

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

Page 58: Basic & Metered - objects.eanixter.com

61

30 Amp, 3 Phase, 8.6kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

XPB3

03-10

3IN6T

L21

XPBA

303-1

03IN

6TL2

1

LINE DRAWING 1 2

AMPS 30 x 3~ 30 x 3~

VOLTS 120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS 120 120

TOTAL RECEPTACLE QTY 30 30

RECEPTACLE TYPE / QTY C-13 / 24 C-13 / 24

RECEPTACLES PER BREAKER AND PHASE 8 8

RECEPTACLE TYPE / QTY C-19 / 6 C-19 / 6

RECEPTACLES PER BREAKER AND PHASE 2 2

MAGNETIC CIRCUIT BREAKER / ON-OFFSWITCH WITH INTEGRAL GUARD YES YES

BREAKER AMPERAGE / QTY 20 / 3 20 / 3

BREAKER POLE CONFIGURATION DOUBLE DOUBLE

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING NO YES *

MONITORING N/APHASE/

BREAKER(X,Y,Z)

10’ POWER CORD 1 1

TWIST-LOCK PLUG L21-30P L21-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH YES YES

DIMENSIONS L (INCHES) 66.25 66.25

DIMENSIONS W 2 2

DIMENSIONS D 2 2

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

1 2

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

Page 59: Basic & Metered - objects.eanixter.com

62

8.6kW 30 Amp, 3 Phase

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

LINE DRAWING 1 2 3 4

AMPS 30 x 3~ 30 x 3~ 30 x 3~ 30 x 3~

VOLTS 120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS 208 208 208 208

TOTAL RECEPTACLE QTY 24 24 12 12

RECEPTACLE TYPE / QTY 6-20R / 24 6-20R / 24 L6-20R / 12 L6-20R / 12

RECEPTACLES PER BREAKER AND PHASE COMBINATION 8 8 4 4

MAGNETIC CIRCUIT BREAKER / ON-OFFSWITCH WITH INTEGRAL GUARD YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 3 20 / 3 20 / 3 20 / 3

BREAKER POLE CONFIGURATION DOUBLE DOUBLE DOUBLE DOUBLE

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING NO YES * NO YES *

MONITORING N/ACIRCUIT/

BREAKER(XY,YZ,ZX)

N/ACIRCUIT/

BREAKER(XY,YZ,ZX)

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L21-30P L21-30P L21-30P L21-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH YES YES YES YES

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25

DIMENSIONS W 2 2 2 2

DIMENSIONS D 2 2 2 2

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

DELTA Unit Confi guration Option: 21= WYE L21-30P Plug / 15= DELTA L15-30P Plug

XPB2

48-10

3D20

TL21

XPBA

248-1

03D2

0TL2

1XP

B128

-103L

20TL

21XP

BA12

8-103

L20T

L21

1 2 3 4

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

Page 60: Basic & Metered - objects.eanixter.com

63

30 Amp, 3 Phase, 8.6kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

1 2 3 4

XPB3

08-10

3IN6T

L21

XPBA

308-1

03IN

6TL2

1XP

B339

-103M

14TL

21XP

W24

9-103

M46T

L21

LINE DRAWING 1 2 3 4

AMPS 30 x 3~ 30 x 3~ 30 x 3~ 30 x 3~

VOLTS 120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS 208 208 120 & 208 120 & 208

TOTAL RECEPTACLE QTY 30 30 33 24

RECEPTACLE TYPE / QTY C-13 / 24 C-13 / 24 C-13 / 24 C-13 / 12

RECEPTACLES PER BREAKER AND PHASE COMBINATION 8 8 8 4

RECEPTACLE TYPE / QTY C-19 / 6 C-19 / 6 C-19 / 3 C-19 / 6

RECEPTACLES PER BREAKER AND PHASE COMBINATION 2 2 1 2

RECEPTACLE TYPE / QTY N/A N/A 5-20R / 6 5-20R / 6

RECEPTACLES PER BREAKER AND PHASE N/A N/A 2 2

MAGNETIC CIRCUIT BREAKER / ON-OFFSWITCH WITH INTEGRAL GUARD YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 3 20 / 3 20 / 3 20 / 3

BREAKER POLE CONFIGURATION DOUBLE DOUBLE DOUBLE DOUBLE

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING NO YES * NO NO

MONITORING N/ACIRCUIT/

BREAKER(XY,YZ,ZX)

N/A N/A

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L21-30P L21-30P L21-30P L21-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH YES YES YES YES

DIMENSIONS L (INCHES) 66.25 66.25 66.25 70

DIMENSIONS W 2 2 2 2

DIMENSIONS D 2 2 2 2

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

DELTA Unit Confi guration Option: 21= WYE L21-30P Plug / 15= DELTA L15-30P Plug

Page 61: Basic & Metered - objects.eanixter.com

64

16.6kW 30 Amp, 3 Phase

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

YB30

3-103

IN6T

L22

YBA3

03-10

3IN6T

L22

LINE DRAWING 1 2 3 4

AMPS 30 x 3~ 30 x 3~ 30 x 3~ 30 x 3~

VOLTS 230 / 400 WYE

230 / 400 WYE

230 / 400 WYE

230 / 400 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS 230 230 230 230

TOTAL RECEPTACLE QTY 30 30 30 30

RECEPTACLE TYPE / QTY C-13 / 24 C-13 / 24 C-13 / 24 C-13 / 24

RECEPTACLES PER BREAKER AND PHASE 8 8 8 8

RECEPTACLE TYPE / QTY C-19 / 6 C-19 / 6 C-19 / 6 C-19 / 6

RECEPTACLES PER BREAKER AND PHASE 2 2 2 2

MAGNETIC CIRCUIT BREAKER / ON-OFFSWITCH WITH INTEGRAL GUARD YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 3 20 / 3 20 / 3 20 / 3

BREAKER POLE CONFIGURATION DOUBLE DOUBLE DOUBLE DOUBLE

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING NO YES * NO YES *

MONITORING N/APHASE /

BREAKER(X,Y,Z)

N/APHASE /

BREAKER(X,Y,Z)

10’ POWER CORD 1 1 1 1

TWIST-LOCK PLUG L22-30P L22-30P N/A N/A

IEC 60309 PIN & SLEEVE CONNECTOR N/A N/A 30A, 230/400V4P / 5W

30A, 230/400V4P / 5W

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH YES YES YES YES

DIMENSIONS L (INCHES) 66.25 66.25 66.25 66.25

DIMENSIONS W 2 2 2 2

DIMENSIONS D 2 2 2 2

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

1 2 3 4

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

ew 230/400V ew 230/400V

YB30

3-103

IN6P

S56

YBA3

03-10

3IN6P

S56

ew 230/400V ew 230/400V

Page 62: Basic & Metered - objects.eanixter.com

65

35 Amp, 3 Phase, 10.1kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

ZPB3

68-10

5IT6C

S15-3

5

LINE DRAWING 1

AMPS 35 x 3~

VOLTS 208 DELTA

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS 208

TOTAL RECEPTACLE QTY 36

RECEPTACLE TYPE / QTY C-13 / 30

RECEPTACLES PER BREAKER AND PHASE COMBINATION 10

RECEPTACLE TYPE / QTY C-19 / 6

RECEPTACLES PER BREAKER AND PHASE COMBINATION 2

MAGNETIC CIRCUIT BREAKER / ON-OFFSWITCH WITH INTEGRAL GUARD YES

BREAKER AMPERAGE / QTY 20 / 3

BREAKER POLE CONFIGURATION DOUBLE

10’ POWER CORD 1

CALIFORNIA STYLE 50A, 250V3P / 4W

FULL-LENGTH VERTICAL MOUNTING BRACKET YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH YES

DIMENSIONS L (INCHES) 66.25

DIMENSIONS W 2

DIMENSIONS D 2

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• Detailed wiring diagram available on page 181.• UL® & c-UL® Listed 60950

1

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

Page 63: Basic & Metered - objects.eanixter.com

66

8.3kW - 10kW 50 & 60 Amp, 208 Volt

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

LINE DRAWING 1 2 3 4

AMPS 50 50 60 60

VOLTS 208 208 208 208

TOTAL RECEPTACLE QTY 3 9 3 9

RECEPTACLE TYPE / QTY C-19 / 3 C-19 / 9 C-19 / 3 C-19 / 9

RECEPTACLES PER BREAKER 1 3 1 3

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 3 20 / 3 20 / 3 20 / 3

BREAKER POLE CONFIGURATION DOUBLE DOUBLE DOUBLE DOUBLE

10’ POWER CORD 1 1 1 1

IEC 60309 PIN & SLEEVE CONNECTOR N/A N/A 60A, 250V2P / 3W

60A, 250V2P / 3W

CALIFORNIA STYLE 50A, 250V 2P / 3W

50A, 250V 2P / 3W N/A N/A

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS YES YES YES YES

DIMENSIONS H (INCHES) 1.72 1.72 1.72 1.72

DIMENSIONS W 17 17 17 17

DIMENSIONS D 6.5 8.5 6.5 8.5

ZP03

0-105

C19C

S6ZP

090-1

05C1

9CS6

ZP03

0-106

C19P

S6

• UL® & c-UL® Listed 60950 ZP09

0-106

C19P

S6

1

2

3

4

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

Page 64: Basic & Metered - objects.eanixter.com

67

60 Amp, 208 Volt, 10kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & MeteredSatellite

MonitoredBasic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

ZPB3

00-10

6IN6P

S6ZP

BA30

0-106

IN6P

S6

LINE DRAWING 1 2

AMPS 60 60

VOLTS 208 208

TOTAL RECEPTACLE QTY 30 30

RECEPTACLE TYPE / QTY C-13 / 24 C-13 / 24

RECEPTACLES PER BREAKER AND PHASE 8 8

RECEPTACLE TYPE / QTY C-19 / 6 C-19 / 6

RECEPTACLES PER BREAKER AND PHASE 2 2

MAGNETIC CIRCUIT BREAKER / ON-OFFSWITCH WITH INTEGRAL GUARD YES YES

BREAKER AMPERAGE / QTY 20 / 3 20 / 3

BREAKER POLE CONFIGURATION DOUBLE DOUBLE

CURRENT MONITORING - LOCAL SCROLLING NO YES *

MONITORING N/A BREAKER

10’ POWER CORD 1 1

IEC 60309 PIN & SLEEVE CONNECTOR 60A, 250V2P / 3W

60A, 250V2P / 3W

FULL-LENGTH VERTICAL MOUNTING BRACKET YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH YES YES

DIMENSIONS L (INCHES) 66.25 66.25

DIMENSIONS W 2 2

DIMENSIONS D 2 2

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

1 2

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

Page 65: Basic & Metered - objects.eanixter.com

68

17.3kW 60 Amp, 3 Phase

Basic & Metered

w w w . g e i s t m f g . c o m

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

2ZPR

128-1

06C1

9PS1

5ZP

B128

-106C

19PS

15ZP

B248

-106IB

BPS1

5ZP

W45

8-106

C13P

S15

LINE DRAWING 1 2 3 4

AMPS 60 X 3~ 60 X 3~ 60 X 3~ 60 X 3~

VOLTS 208 DELTA 208 DELTA 208 DELTA 208 DELTA

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS 208 208 208 208

TOTAL RECEPTACLE QTY 12 12 24 45

RECEPTACLE TYPE / QTY C-19 / 12 C-19 / 12 C-13 / 12 C-13 / 45

RECEPTACLES PER BREAKER 2 2 2 15

RECEPTACLE TYPE / QTY N/A N/A C-19 / 12 N/A

RECEPTACLES PER BREAKER N/A N/A 2 N/A

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD YES YES YES YES

BREAKER AMPERAGE / QTY 20 / 6 20 / 6 20 / 6 20 / 3

BREAKER POLE CONFIGURATION DOUBLE DOUBLE DOUBLE TRIPLE

10’ POWER CORD 1 1 1 1

IEC 60309 PIN & SLEEVE CONNECTOR 60A, 250V3P / 4W

60A, 250V3P / 4W

60A, 250V3P / 4W

60A, 250V3P / 4W

2U RECESSED MOUNTING BRACKETS YES NO NO NO

FULL-LENGTH VERTICAL MOUNTING BRACKET NO YES YES YES

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES) N/A 61.25 &

64.7561.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH N/A NO NO YES

DIMENSIONS L/H (INCHES) 3.4 66.25 66.25 70

DIMENSIONS W 17 2.3 2.3 3

DIMENSIONS D 9 3.45 3.45 2

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• Detailed wiring diagram available on page 181.• UL® & c-UL® Listed 60950

1 2 3 4

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

Page 66: Basic & Metered - objects.eanixter.com

69

80 & 120 Amp, 3 Phase, 23kW - 34.5kW

8 0 0 - 4 3 2 - 3 2 1 9

Basic & Metered

ZPB1

28-X

X8C1

9HW

15-B

EZP

B048

-XXX

T30H

W15

-BE

LINE DRAWING 1 2

AMPS 80 x 3~ 120 x 3~

VOLTS 208 DELTA 208 DELTA

OUTPUT VOLTAGE FOR 3 PHASE INPUT 208 208 DELTA

TOTAL RECEPTACLE QTY 12 4

RECEPTACLE TYPE / QTY C-19 / 12 L15-30R / 4

RECEPTACLES PER BREAKER 3 1

MAGNETIC CIRCUIT BREAKER / ON-OFFSWITCH WITH INTEGRAL GUARD YES YES

BREAKER AMPERAGE / QTY 20 / 4 30 / 4

BREAKER POLE CONFIGURATION TRIPLE TRIPLE

HARDWIRED - WIRING ACCESS PANEL - CONDUIT CONNECTION ACCESS YES YES

HARDWIRED CONNECTION OPENING 1.5” TRADE SIZE

1.5” TRADE SIZE

TERMINAL BLOCK ACCEPTS WIRE GAUGE 14 - 2/0 14 - 2/0

SUGGESTED BRANCH CIRCUIT BREAKER RATING 100A 150A

TOOLLESS MOUNTING HARDWARECENTER TO CENTER SPACING (INCHES)

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES) 66.25 66.25

DIMENSIONS W 3.5 3.5

DIMENSIONS D 3.5 3.5

• All 3 phase and multi-input units have color-coded receptacle confi gurations or labeling for easy identifi cation and load balancing• Detailed wiring diagram for 80A unit available on page 181.• UL® & c-UL® Listed 60950

1 2

SatelliteMonitored

Basic & Metered

SwitchedEducational

SoftwareEnvironmental

AccessoriesBrackets

Resources

Page 67: Basic & Metered - objects.eanixter.com

70

Inline Metered

w w w . g e i s t m f g . c o m

LCE-

001C

13-00

C14

LCE-

002C

19-00

C20

LINE DRAWING 1 2

AMPS 15 20

VOLTS 120 or 208 120 or 208

TOTAL RECEPTACLE QTY 1 1

RECEPTACLE TYPE / QTY C-13 / 1 C-19 / 1

CIRCUIT BREAKER / ON-OFF SWITCH NO NO

POWER MONITORING - LOCALPOWER FACTOR / AMPS / VOLTS / WATTS YES * YES *

MONITORING AGGREGATE AGGREGATE

CURRENT MONITORING - LOCALAMPS - AGGREGATE OPT * OPT *

IEC POWER INLET C-14 C-20 WITH CORD RETAINING CLAMP

PANEL MOUNTING INTEGRAL BRACKETS YES YES

DIMENSIONS H (INCHES) 2.5 2.5

DIMENSIONS W 6.25 6.25

DIMENSIONS D 1.6 1.6

IEC inlet units allow the PDU to supply 120V, 208V or 230V. The voltage distributed is determined by the voltage input. (For a complete off ering of IEC Cord Sets see page 169)

• UL® & c-UL® Listed 60950* Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Current Monitoring Option: Replace C with A in part number

1

2

1.4kW - 3.3kW 15 & 20 Amp, 120 or 208 Volt

Satel

liteSw

itche

d M

onito

red

Basic

&

Meter

edSo

ftwar

eEn

viron

menta

lAc

cess

ories

Brac

kets

Reso

urce

sEd

ucati

onal

Page 68: Basic & Metered - objects.eanixter.com

718 0 0 - 4 3 2 - 3 2 1 9

Basic & Metered

Notes

NotesSatellite

MonitoredSwitched

EducationalSoftware

EnvironmentalAccessories

BracketsResources


Recommended