Form-I for seeking clearance for project attracting CRZ notification
Basic Information:
Name of the Project :- Proposed Star Hotel Project ( M/s East Venice Hotels and Resorts Pvt. Ltd. )
Location or site alternative under consideration: - Survey Nos. 6, 6/2-3, 6/2-2, 6/2, Alappuzha West Village, Alappuzha District, Kerala
Size of the project ( in terms of total area ):- 1,944 Sq. m. ( 0.1944 ha. ) ( Plot Area ) 4,231.10 sq. m. ( Total Built-up Area ) Proposed Hotel Rooms = 42 Rooms FAR Proposed = 3,604 Sq. m. ( @ 1.85 ) FAR Permissible = 7,776 sq. m. (@4)
CRZ classification of the area :- CRZ – II (The project site is near Alappuzhha Sea coast the CRZ is 500m landward of HTL of the Sea. Being in Alappuzha Municipality the site is in CRZ II. The proposed site development is landward of the 200m line from HTL of the Sea. The site under development is a vacant plot in a well-developed commercial area near Alappuzha beach in Alappuzha Municipality. The CRZ Status report, confirming above aspects of the CRZ Classification of the project site as prepared by NCESS is attached ).
Expected cost of the project: - Rs. 11 Crores
Contact Information:- M/s East Venice Hotels and Resorts Pvt. Ltd. Shanisha, Arattuvazhi, Alappuzha District, Kerala – 688007 Mr. T. P. SHAN ( Managing Director)
Tel. No. 0477-2242281 & 2246356 Mobile No. 9447972281 e-mail: [email protected] ( II ) Activity
1. Construction, operation or decommissioning of the Project involving actions, which will cause
physical changes in the locality ( topography, land use, changes in water bodies, and the like )
S.
No.
Information / Checklist confirmation Yes /
No
Details thereof (with approximate quantities /
rates, wherever possible) with source of
information data
1.1 Permanent or temporary change in land use,
land cover or topography including increase in
intensity of land use ( with respect to local land
use plan )
Yes The proposed project is Star Hotel Project in
Alappuzha Municipality. The proposed project
site is located at well developed commercial
area and confirms the land use.
1.2 Details of CRZ classification as per the
approved Coastal Zone Management Plan?
Yes The project site is near Alappuzhha Sea coast
the CRZ is 500m landward of HTL of the Sea.
Being in Alappuzha Municipality the site is in
CRZ II. The proposed site development is
landward of the 200m line from HTL of the Sea.
The site under development is a vacant plot in
a well-developed commercial area near
Alappuzha beach in Alappuzha Municipality.
The CRZ Status report, confirming above
4
aspects of the CRZ Classification of the project
site as prepared by NCESS is attached
1.3 Whether located in CRZ-I area? No Being in Alappuzha Municipality and within
500m landward of HTL of the Sea, the project
site is CRZ-II area.
1.4 The distance from the CRZ-I area. Yes The approved CRZ Map showing CRZ-I, CRZ II
and CRZ IV area near the site is attached.
Being in Alappuzha Municipality and within
500m landward of HTL of the Sea, the project
site is CRZ-II area.
1.5 Whether located within the hazard zone as
mapped by Ministry of Environment and
Forests / National Disaster Management
Authority?
No The proposed site in not located in hazard
zone. The site development work will be
outside 200m towards landward from HTL of
Sea and within Alappuzha Municipality.
Further, site specific disaster management
plan will be prepared and followed to manage
any disaster at site.
1.6 Whether the area is prone to cyclone, tsunami,
tidal surge, subduction, earthquake etc.?
Yes The project site is along the Sea coast and
within 500 m from HTL and hence there may be
chances of cyclone, tsunami, tidal surge,
subduction, earthquake etc. in the vicinity.
Disaster management plan will be prepared
and followed to manage site during any
disaster.
1.7 Whether the area is prone for saltwater
ingress?
Yes The project site is along the Sea coast and
within 500 m from HTL. The salinity in dry
season is more than 5 ppt and hence the
project area and the surroundings attracts the
CRZ provisions.
1.8 Clearance of existing land, vegetation and
buildings?
Yes There are some native species of trees and
different varieties of shrubs, herbs, grass &
climbers at site. For development of the
proposed project, some trees will be cleared.
1.9 Creation of new land uses? Yes The proposed site is within developed
commercial area.
1.10 Pre-construction investigations e.g. bore hole,
soil testing?
Yes Per-construction soil investigation has been
carried out for the site.
1.11 Construction Works? Yes Construction of 42 hotel rooms with internal
roads, parking & services etc.
1.12 Demolition Works? No The site is vacant land and no demolition is
required for site development.
1.13 Temporary sites used for construction works,
or housing of construction workers?
Yes
Temporary sheds will be constructed for
housing of construction workers (About 50
persons)
1.14 Above ground buildings, structures or
earthworks including linear structures, cut and
fill or excavations
Yes It is proposed to construct 42 hotel rooms. The
hotel block is with Basement + Ground + 5
Floors with a maximum height about 20.6m.
Excavation of earthwork for foundation of
structures will be carried out. The excavated
top soil will be used for landscaping, internal
road construction and for backfilling purposes.
1.15 Underground works including mining or
tunneling?
No No underground works including mining /
tunneling is required.
1.16 Reclamation works? No No Reclamation work is required.
1.17 Dredging / reclamation / land filling / disposal of No No dredging, reclamation, land filling is
5
dredged material etc.? required.
1.18 Offshore structures? No No offshore structure is required.
1.19 Production and manufacturing processes? No No production / manufacturing process
involved. Proposed project is a construction
project.
1.20 Facilities for storage of goods or materials? Yes Separate raw material handling yard will be
made within the project premises.
1.21 Facilities for treatment or disposal of solid
waste or liquid effluents?
Yes Construction Phase: -
Municipal Solid waste generated from the
project during construction phase will be about
20 kg/day and the domestic sewage will be
about 5.50 KL / day. The non-biodegradable
waste and other packaging materials will be
sold to the vendors. The bio-degradable solid
waste will be disposed through a bio-bin
system for microbial composting and a septic
tank for the domestic sewage from the labour
colony is proposed.
Operation Phase:-
Solid waste generated from the project would
be about 60 Kg/Day and adequate number of
collection bins separately for Bio-degradable
and Non-biodegradable waste would be
provided as per the MSW Rules, 2000. The non-
biodegradable and recyclable waste would be
sold to the recyclers. The biodegradable waste
would be sent to bio-bin facility proposed
within the site.
Further, the spent oil from the DG Sets (defined
as hazardous waste) will be sold to CPCB
approved recyclers.
Effluent : - Domestic sewage about 16 KL / Day
will be generated which will be treated through
proposed Sewage Treatment Plant to be
developed within the project premises.
1.22 Facilities for long term housing of operational
workers?
No The proposed project is a hotel project and
operational workers will be hired locally and
therefore, no housing facilities will be required
for operational workers.
1.23 New road, rail or sea traffic during construction
or operation?
No Not Applicable
1.24 New road, rail, air waterborne or other
transport infrastructure including new or altered
routes and stations, port airport etc.?
No Not Applicable
1.25 Closure or diversion of existing transport routes
or infrastructure leading to changes in traffic
movements?
No Not Applicable
1.26 New or diverted transmission lines or
pipelines?
No Not Applicable
1.27 Impoundment, damming, culverting,
realignment or other changes to the hydrology
of watercourses or aquifers?
No No impoundment, damming, culverting,
realignment or other changes to the hydrology
of surface water courses is proposed.
1.28 Stream and river crossings? No No stream crossing in the project site. Further,
the project site is located near Alappuzha
Coastal area. There is no stream or river
6
crossing.
1.29 Abstraction or transfers of water from ground
or surface waters?
No No water from open well will be proposed.
1.30 Changes in water bodies or the land surface
affecting drainage or run-off?
No The run-off from the site will be channelized
properly and the drainage of the project site
and its surroundings will not be affected.
1.31 Transport of personnel or materials for
construction, operation or decommissioning?
Yes Transportation of personnel / material during
the construction and operation phase are
envisaged. In the construction phase, approx.
2-3 trucks / day is envisaged. During operation
phase the occupants and the visitors use their
vehicles for commutation.
1.32 Long-term dismantling or decommissioning or
restoration works ?
No Not Applicable
1.33 Ongoing activity during decommissioning
which could have an impact on the
environment?
No Not Applicable
1.34 Influx of people to an area in either temporarily
or permanently?
No The proposed project is a Commercial project
and the project would provide some direct /
indirect jobs facilities in the operation phase
and about 50 nos. of local labourers (skilled /
unskilled) would be engaged during
construction phase.
Further, on full occupancy of the project, the
maximum population expected is 100 Persons
and hence there will be influx of people due to
the project at the project site.
1.35 Introduction of alien species? No Not Applicable
1.36 Loss of native species or genetic diversity? Yes There are some native trees, shrubs, herbs and
grass existing at site, some of them are native
species, will be lost during site development.
1.37 Any other actions? None Nil
2. Use of Natural resources for construction or operation of the Project ( such as land, water, materials
or energy, especially any resources which are non-renewable or in short supply):
S.
No.
Information / checklist confirmation Yes /
No
Details thereof ( with approximate quantities /
rates, wherever possible ) with source of
information data
2.1 Land especially undeveloped or agricultural
land ( ha )
Yes Plot of 0.1944 Hectares is the undeveloped land with some native trees, shrubs, herbs and grass existing at site. The project site occupy very less space for land cover and vertical growth is proposed.
2.2 Water (expected source & competing users )
unit: KLD
Yes Construction phase: - The daily water consumption during construction phase is for domestic requirement (7 KLD) of the construction labourers and for construction purposes requirement is 10 KLD. The source of water will be from stored rain water in tank and Public Supply / Water tankers. Operation Phase: - The total daily domestic water consumption for proposed project would be 20 KLD (which includes fresh water requirement of 13.5 KL). The sources of water during operation phase are: - 1. Roof Rain Water (Rainy Days-Concurrent
7
use) (Non-flushing). 2. Public Supply from KWA (Non-flushing
requirement) (Non-rainy days) 3. Treated water from STP (Flushing
requirement) (Entire year) The break-up details regarding the water consumption & waste water generation are provided at daily water balance chart attached.
2.3 Minerals ( MT ) No Not Applicable
2.4 Construction material – stone, aggregates,
sand / soil ( expected source – MT )
Yes Steel : 1,000 MT M-Sand: 8,500 Cu. m. Cement & Laterite Blocks : 4,000 Cu. m. Cement : 5,000 Bags It shall be procured from local market
2.5 Forests and timber ( source – MT ) Yes Wood shall be used for doors, however recyclable wood shall be used for doors.
2.6 Energy including electricity and fuels (source,
competing users) Unit: fuel (MT), energy (MW)
Yes Power Requirement = 200 KW Power Source : Kerala State Electricity Board & D.G. Sets = 200 KVA X 1 No. (Standby arrangement) Fuel – Low Sulphur HSD
2.7 Any other natural resources ( use appropriate
standard units )
No Not Applicable
3. Use, storage, transport, handling or production of substances or materials, which could be harmful to human health or the environment or raise concerns about actual or perceived risks to human health.
S.
No.
Information / Checklist confirmation Yes
/ No
Details thereof ( with approximate quantities /
rates, wherever possible ) with source of
information data
3.1 Use of substances or materials, which are
hazardous (as per MSIHC rules) to human
health or the environment (flora, fauna, and
water supplies)
Yes This is a commercial project and no storage of
hazardous chemicals. ( as per MSIHC Rules ) will
be done, apart from used oil from D.G. Sets and
suitable arrangement will be adopted for the
same. It will be stored in HDPE drums and kept
in secured rooms under lock and will be sold to
CPCB approved vendors only.
3.2 Changes in occurrence of disease or affect
disease vectors ( e.g. insect or water borne
diseases )
No Suitable drainage & waste management
measures will be adopted both in the
construction and operation phase which will
restrict stagnation of water or accumulation of
water. This will effectively restrict the
reproduction and growth of disease vectors.
Further, appropriate sanitation facility will be
provided at site during construction phase &
operation phase. Good house-keeping and
hygienic measures will be followed during
construction and operation phase to avoid any
cause which can lead to occurrence of disease.
3.3 Affect the welfare of people e.g. by changing
living conditions?
Yes The proposed project is a commercial hotel
project and thereby the living index of the people
around the project site will definitely improve.
Also there will be various ancillary activities like
convenient shops, transport facilities etc.
attached to the project which will benefit the
local people and change their living condition.
3.4 Vulnerable groups of people who could be
affected by the project e.g. hospital patients,
No Not Applicable. There is no storage of any
material within the site which will affect the
8
children, the elderly etc., vulnerable groups of people.
3.5 Any other causes, that would affect local
communities, fisherfolk, their livelihood, dwelling
unit of traditional local communities etc
None
4. Production of solid wastes during construction or operation or decommissioning ( MT / Months )
S.
No.
Information / Checklist confirmation Yes
/ No
Details thereof ( with approximate quantities /
rates, wherever possible ) with source of
information data
4.1 Spoil, overburden or mine wastes No No such spoil over burden or mine waste will be
generated. The construction debris will be used
for backfilling purposes.
4.2 Municipal waste ( domestic and or commercial
wastes )
Yes There will be about 20 kg/ day of municipal solid
waste during construction phase.
The total municipal solid waste generated from
the project would be about 60 kg / day on full
occupancy during operation phase.
4.3 Hazardous wastes (as per Hazardous Waste
Management Rules )
Yes The oil used in the DG Sets (as standby source
of power) after certain hours of operation, needs
to be changed. This used oil from the DG Sets
will be sold to the CPCB approved recyclers. The
list of authorized recyclers are M/s Perfect
alloys, Changannur, M/s Peejay Enterprises,
Thiruvalla, M/s Excel Petrochemicals, Kochi &
M/s Cee Jee Lubricants, Aluva are the approved
recyclers for discarded batteries & used oil
located in Kerala.
Used oil will be stored in HDPE drums in isolated
covered facility.
4.4 Other industrial process wastes No Not Applicable
4.5 Surplus product No Not Applicable
4.6 Sewage sludge or other sludge from effluent
treatment
Yes The sludge from STP will be partially recycled for
enhancing biological treatment and the excess
sludge will be sent to the filter press and the de-
canted sludge will be used as manure in green
area during operation phase.
4.7 Construction or demolition wastes Yes Construction waste & demolition waste will be
used for back filling purposes.
4.8 Redundant machinery or equipment No Not Applicable
4.9 Contaminated soils or other materials No Not Applicable
4.10 Agricultural wastes No Not Applicable
4.11 Other solid wastes Yes Some horticulture waste will be generated and
which will be stored along with bio-degradable
waste and would be disposed accordingly.
5. Release of pollutants or any hazardous, toxic or noxious substances to air ( Kg / hr. )
S.
No.
Information / Checklist confirmation Yes /
No
Details thereof ( with approximate quantities /
rates, wherever possible ) with source of
information data
5.1 Emissions from combustion of fossil fuels from
stationary or mobile sources
Yes The operation of proposed project does not
envisage any major air pollutant generating
sources except D.G. Sets and vehicular
movement during construction phase and
operation phase. It is proposed to have a DG
9
Set of 62.5 kVA x 1 No. capacity during
construction phase and 200 KVA x 1 No. during
operation phase.
5.2 Emissions from production processes No Not Applicable. No production activity
envisaged.
5.3 Emissions from materials handling including
storage or transport
Yes This will be restricted to the construction phase
and within the project site only.
5.4 Emissions from construction activities
including plant and equipment
Yes Dust will be generated during unloading of
construction materials, drilling and grinding
operation etc. this will be restricted to the
construction phase and within the site only.
The other source of emission is from DG Sets of
62.5 kVA of 1 no. which will be used during
construction phase.
5.5 Dust or odours from handling of materials
including construction materials, sewage and
waste
Yes During construction phase dust will be
generated during the handling of construction
materials, sprinklers for suppression of dust
will be installed during construction phase to
minimize the dust operation.
Wind breakers (i.e. barricades with GI Sheets) at
all vulnerable sides (all along the nearby
houses) or location or using shade nets will be
used for dust control.
5.6 Emissions from incineration of waste No Not Applicable, no incineration proposed.
5.7 Emissions from burning of waste in open air
(e.g. slash materials, construction debris )
No Not Applicable
5.8 Emissions from any other sources No Not Applicable
6. Generation of Noise and Vibration, and Emissions of Light and Heat:
S.
No.
Information / Checklist confirmation Yes /
No
Details thereof ( with approximate quantities /
rates, wherever possible ) with source of
information data
6.1 From operation of equipment e.g. engines,
ventilation plant, crushers
Yes
During construction phase, the machinery used
for construction will be of highest standard with
reputed make and will adhere to international
standards. These standards itself take care of
noise pollution control. Hence insignificant
impacts due to construction machinery are
envisaged.
The source of vibration from the project is
during construction of the building. Pile
foundation excavation through rotary drilling is
the source of vibration. The PPV levels from the
rotary drilling for pile foundation would be
maintained within 10 mm/sec at 20 m from the
source. Therefore, there will not be any damage
due to the vibration generated during
foundation work to the nearby structures.
Apart from this, the construction activity will be
restricted to day time only.
Noise will be created from operation of D.G.
Sets but all the D.G. Sets shall be acoustic fitted
to restrict the noise within the permissible limit.
Noise barriers all along the project boundary
will be created. Also marble / tile cutting area
noise barrier enclosures at appropriate height.
10
6.2 From industrial or similar processes No Not Applicable
6.3 From Construction or demolition Yes Due to the various construction activities there
will be short term noise impacts in the
immediate vicinity of the project site. The
construction activity will include the following
noise generation activities:
Operation of D.G. Sets, concreting and mixing.
Excavation, jack hammer, etc.
6.4 From blasting or piling No No blasting or mechanized piling will be used in
the construction phase.
6.5 From construction or operational traffic Yes Some amount of noise will be generated from
vehicular movement in the construction and
operation phase.
6.6 From lighting or cooling systems Yes The lighting proposed within the project area
during construction phase and operation phase
will be limited to the permissible lux level. The
proposed project is hotel project thereby no
Central air conditioning system is required.
6.7 From any other sources No Not Applicable
7. Risks of contamination of land or water from releases of pollutants into the ground or into sewers, surface
waters, ground water, coastal waters or the sea:
S.
No.
Information / Checklist confirmation Yes /
No
Details thereof ( with approximate quantities /
rates, wherever possible ) with source of
information data
7.1 From handling, storage, use or spillage of
hazardous materials
No Used Oil from the D.G. Sets will be stored in a
separate place and sold to CPCB approved
recyclers. Used oil will be stored in HDPE
drums in isolated covered facility. The storage
of used oil will be in such a way that no spillage
of hazardous materials.
7.2 From discharge of sewage or other effluents
to water or the land (expected mode and
place of discharge)
No Sewage will be disposed off through proposed
Sewage Treatment Plant to be developed within
the premises and treated water will be used for
flushing & horticulture purposes within the site.
7.3 By deposition of pollutants emitted to air into
the land or into water
No Not Applicable
7.4 From any other sources No Not Applicable
7.5 Is there a risk of long term build up of
pollutants in the environment from these
sources?
No Not Applicable
8. Risk of accidents during construction or operation of the Project, which could affect human health or the
environment
S.
No.
Information / Checklist confirmation Yes
/ No
Details thereof ( with approximate quantities /
rates, wherever possible ) with source of
information data
8.1 From explosions, spillages, fires etc from
storage, handling, use or production of
hazardous substances
No This is basically a commercial project and does
not involve any major hazardous construction
activity. Hence chances of explosions, spillages,
fires are minimal.
During Construction all the labours will be
provided with suitable personal protective
equipment (PPE) as required under the health &
safety norms. Training and awareness about the
11
safety norms will be provided to all supervisors
and labours involved in construction activity.
An agreement will be signed with the contractor
which will clearly deals with the safety aspects
during construction.
No major hazardous waste is being stored within
the project site. No Industrial or process activity
is involved and hence chances of chemical
hazards are minimal. However, suitable fire
fighting measures will be provided.
8.2 From any other causes No Not Applicable
8.3 Could the project be affected by natural
disasters causing environmental damage
(e.g., floods, earthquakes, landslides,
cloudburst etc)?
No As per seismic classification, the project site
falls in Zone-III. No report of cloudburst in the
area. Also there is no hilly area around the
project site, there is no chance of landslide.
Appropriate measures will be taken to protect
the stream passing near the site.
Structural design aspects as per seismic code
would be incorporated as per norms.
9. Factors which should be considered (such as consequential development) which could lead to environmental
effects or the potential for cumulative impacts with other existing or planned activities in the locality
S.
No.
Information / Checklist confirmation Yes /
No
Details thereof ( with approximate quantities /
rates, wherever possible ) with source of
information data
9.1 Lead to development of supporting facilities,
ancillary development or development
stimulated by the project which could have
impact on the environment e.g.:
Supporting infrastructure (roads, power supply,
waste or waste water treatment, etc.)
housing development
extractive industries
supply industries
other
Yes
No
No
No
No
Appropriate infrastructure like roads, power
supply, waste management and waste water
treatment will be developed within the site so
that chances of occurrence of any adverse
impacts are minimized.
During construction skilled, unskilled and
professional work force including temporary and
permanent employees shall be hired locally in
order to generate the employment to the local
people. While during the project operation stage
for the purposes of day-to-day maintenance
workers will be employed. Moreover, some more
employment will be created as a result of
positive induced development in the immediate
vicinity.
Proposed Hotel Project
Not Applicable
Not Applicable
Not Applicable
9.2 Lead to after-use of the site, which could have
an impact on the environment
No Not Applicable
9.3 Set a precedent for later developments No Not Applicable
9.4 Have cumulative effects due to proximity to
other existing or planned projects with similar
effects
No Not Applicable
12
III Environmental Sensitivity
S.
No.
Area Name /
Identity
Aerial distance ( within 15 km. )
Proposed project location boundary
1. Areas protected under international conventions,
national or local legislation for their ecological,
landscape, cultural or other related value
Lakshadweep
Sea
Within 500m radius
2. Areas which are important or sensitive for
ecological reasons - Wetlands, watercourses or
other water bodies, coastal zone, biospheres,
mountains, forests
Lakshadweep
Sea
Within 500m radius
3. Areas used by protected, important or sensitive
species of flora or fauna for breeding, nesting,
foraging, resting, over wintering, migration
Lakshadweep
Sea
Within 500m radius
4. Inland, coastal, marine or underground waters Sea Within 500m radius
5. State, National boundaries None None within 15 km radius
6. Routes or facilities used by the public for access
to recreation or other tourist, pilgrim areas
NH-47 National Highway-47 is about 1 km away
from the site.
7. Defence installations No Not Applicable
8. Densely populated or built-up area Alappuzha
City
The project site is within City limits and
is densely populated.
9. Areas occupied by sensitive man-made land
uses (hospitals, schools, places of worship,
community facilities)
Yes Several Hospitals, Schools, Temples and
community centre areas are located near
the site within 15 km.
10. Areas containing important, high quality or
scarce resources (ground water resources,
surface resources, forestry, agriculture, fisheries,
tourism, minerals)
No None within the area.
11. Areas already subjected to pollution or
environmental damage. (those where existing
legal environmental standards are exceeded)
No No critically polluted area is located
within 15 KM radius.
12. Areas susceptible to natural hazard which could
cause the project to present environmental
problems (earthquakes, subsidence, landslides,
erosion, flooding or extreme or adverse climatic
conditions)
CRZ Status
Seismic Zone
No reported incidence of earthquakes,
subsidence, landslides, erosion, flooding
or extreme or adverse climatic condition
at site.
The project site is near Alappuzhha Sea
coast the CRZ is 500m landward of HTL
of the Sea. Being in Alappuzha
Municipality the site is in CRZ II. The
proposed site development is landward
of the 200m line from HTL of the Sea. The
site under development is a vacant plot
in a well-developed commercial area
within Alappuzha Municipality. The CRZ
Status report, confirming above aspects
of the CRZ Classification of the project
site as prepared by NCESS is attached.
The project area falls in Zone – III,
accordingly to the Indian Standards
Seismic Zoning Map. Suitable NBC
measures will be adopted while
designing the structures.
13
I hereby give an undertaking that the data and information given above are true to the best of my
knowledge and belief and I am aware that any if any part of the data / information submitted is
found to be false or misleading at any stage, the project is liable to be rejected and the clearance
given, if any, to the project is likely to be revoked at our risk and cost.
Signature of the Applicant
Date: 06. 05.2016
Place: Alappuzha, Kerala
IKI,IIIA I,A (]OAS1hI, ZONIi
No.25 l.s/Ai/ I 6/KCZMA/S&T D'
irf0llr-i iie Nlenlbe l Secretar)'- KCZMA'
lrr
L.td. Alappuzhal. l)ecisiorr No: 75.05.18 in the
Marcir 2016.
MANAG F],MEN'T AT]THOR.ITY
Scierrce & TechnologY (A) DePt'
Sasthra Bhavan' Pattom PO'
Thiruvananthapuram-4. Dated : i0 04 2016
Floor
Jhe.loint Secletaq'-
Nlirristr,r'of Envilonment- Forests & Clinatic Change
(lA-lll Division). Govemment of India' IndiaraParyavaran Rhavan' 3''r
.lorbagh load. New l)elhi- I i 0003
5rf- SLrb:_ S&TD Construction ofStar Hotel project _cM clearance sought by Shri.l.p Shan-
Manasitrg lJirector' East Venice Hotel and Resofis P\t Ltd' Alappuzha-reg
Ref: l. Lr. No. 05.02.l6 tiom the Managing Dilector' East Venice llotels and Resorts l)r t
TbeMarragingDirector.EastVeniceHotelsandResortsPvtLtdllasfrrrnishedaproposatrirl obtair.rir.rg CRZ clearance for construction of Star Hotel Ploje.c].at l" T: ffi'^11^6lt:?:!',t',".
.,.if^fprrfr" iVest Village, Alappuzha Mr-rnicipality' Alappuzha District The proposed area rs rrl
gllZ ll a'd lies o. the funO*liJ ,la" of exisiing-road ut-ta tultaingt The 75'r' meeting of Kclala
(loastal Ztrne Management Authority (KCZMA) held on 23'd March 2016 has discr-rssed tlre
Dr.onosal in cletail and decided to recornnend the same to Ministry of Environment alrd Ftlte sl
iH4otlF) sublect to the pemrissible FAR limits in that area'
hr the above circumstance, I am to recommended the above.proposal on cRZ angle and li'
lirr.rvar.d herewith tl-re fbllowing doctulent. witlt a request to consider the proposal subiect to the
pemissible FAR limits in that area'
a; l)rrlr lillecl ttp Foltrt lapplicationb) llaPid LilA RePort
c)DisasterManagementPlan.RiskAssessmentRepofiandEnvironmentManagementl)lancl) Cltl n,un or"ou-d^ ty Nutionut cer]rre ior Earth Scier.rce Studies (NCESSt'
1 hit uvaualrthaPurame) The CRZ map coveting 7 km radius around the project site'
1) Project layout snpel irnposed on the CRZ- map .
qt Nci Obieition Certiticaie fiom the State Pollorition Control Board'
r.ninutes of the 7-5'r' Meeting ol KCZMA held on 1l"l
ploposal to KCZVIA tn tluc
Yours faithlull]'.
Dr. G GE VARGIIT.SI.,,
Member Secretarl'. KCZMA
I aur to reqtlest You to intbr:m
cor Se.
(lopy to :-1.'l-he District Collector" Alappuzha
2.-[he Secletary. Alappr"rzl.ra Municipality
i. ShLi. T.P Shan- Mar.ragit.rg Director' East Venice Hote and Resofis Pvt Ltd. Alappuzha
FIRE PROTECTION ARRAN
GEMEN
T FOR HOTEL BUILDIN
G(A-5) AS PER NATION
AL BUILDING CODE
OF INDIA PART IV 2005 (ABOVE 15 M
TR BUT NOT EXCEEDIN
G 30 MTRS IN
HEIGH
T)
PROJECT
ARCHITECT
BUILDING OW
NER
05.12.2014D
ATE
K.R.SAJEEV
DRAW
ING NO
CHECKED
RIVISION NO
Soumya
DRAW
NREVIEW
ED
FIRE ALARM CONTROL PANEL
FBC
WET RISER
SINGLE H
OSE HYDRAN
T VALVE
HB
HV
HOOTER CUM
PA SPEAKERH
S
FIRE BRIGADE CONNECTION
MAN
UAL CALL POINT
HOSE BOX
FIRE EXTINGUISH
ERF.Extgr
SYMBOL
DESCRIPTION
LEGEND
HR
HOSE REEL
158/2014
LAND
DETAILS
VILLAGE -
Re.Sy. No. -
DISTRICT -
MU
NICIPLAITY - ALAPPUZH
A
ALAPPUZHA
ALAPPUZHA W
EST
TALUK -
AMBALAPPUZH
A
6, 6/2-3, 6/2-2, 6/2
00
PROPOSED H
OTEL BUILDING
SPRINKLER BULB PENDAN
T TYPE
01
SPRINKLER BULB SIDE W
ALL TYPE
YHYARD H
YDRANT
REGD: O
FFICE @ ERNAKULAM
FIRE PROTECTIO
N EN
GINEERS, CONSULTANTS, CONTRACTORS
Door No:33/3160-A,'Krishna',Behind Ernakulam
Medical Center
Century Club Road,Vennala,Cochin-682 028Ph: +91-484-2805882 Fax-2805880Em
ail: aagindiapvtltd@hotm
ail.comVisit us: w
ww
.aagindia.comM
obile dwg section: 9447723821, M
obile Office : 9446409990
BRANCH
OFFICE @
BANGALOREAag India Private Lim
ited,Patel Muninarayanappa Com
plexH
ennur Bagalur Main Road,Kothanur Post, Bangalore East
Bangalore - 560 077,Mob: 9900053217, 9900053218
E-mail: aagindiabangalore@
gmail.com
Visit us: ww
w.aagindia.com
REGIONAL OFFICE@
CALICUTAag India Private Lim
ited,Regional O
ffice: (North K
erala),SeikenC
hambers,K
annur Road, K
ozhikode - 6730 01Ph: 0495 - 3043884, M
ob: 9447723841E-m
ail: aagindiacalicut@gm
ail.comVisit us: w
ww
.aagindia.com
Aag India Private Limited
FIRE CON
SULTANT AT ALAPPUZH
A
SDHD
SMOKE DETECTOR
HEAT DETECTOR
A R
C H
A N
A T O
W E
R S
,N
ear District Industrial C
entre,,K
O L L A
M - 6 9 1 0 0 1
K E
R A
L A
P H
: 4 7 4 2 7 6 0 5 5 7P
H : 4 7 4 3 2 9 6 0 0 0
email id : info@
9architects.comw
ebsite : ww
w.9architects.com
Mr. T.P Shan &
3 Others Shanisha Arattuvazhy W
ard, Alapuzha- 688 007
XX
YY
HARVESTING TANK
(capacity 72,000Ltrs)
RAIN WATER
M.H
.
M.H
.
PR
OPO
SEDB
UILD
ING
SY
.NO
.6,6/3-2, 6/2-2,6/2
(SEWAGE TREATMENT PLANT)
TUBE W
ELLPRO
POSED
FIRE TANK
CAR PARKING
CAR PARKING
TWO WHEELER / CYCLE PARKING
(capacity 1,50,000Ltrs)
A L A
P P
U Z H
A B
E A C H
GATE 5.0m
wide
MA
IN E
NTR
Y
GATE 5.0m
wide
EXIT
M E D
I C A L C
O L L E G
E
LOADING & UNLOADING SPACE
RO
AD
11.0M W
IDE
TWO WHEELER / CYCLE PARKING
0.00 LVL
+1.35 LVL
-15 LVL
SY.N
O.7
SY.N
O.7
+1.20 LVL
0.00 LVL
0.00 LVL
0.00 LVL
+1.35 LVL
CO
MPO
UN
D W
ALL
0.00 LVL
-1.40 LVL
Z Z
FOM
ATIN
G FAC
TOR
Y
FOM
ATIN
G FAC
TOR
Y
W.C
GO
V.H
OS
PITAL
RISER
F.B.C
YH
YH
FBC
BV NRV
BVN
RV
J.P
BV
FIRE FIGHTING SUM
P1,50,000 LTRS ONLY
FOR FIRE FIGHTIN
G PURPOPSE
MAIN ELECTRICAL PUM
P 2280 LPM
NRV
NRV
S.PM
EP
BV
From Static Storage tank
BV NRV
NRV
BV
BA
LL VA
LVE PRESSURE
SWITCH
PRESSU
RE G
AU
GE
AIR
RELEA
SE VA
LVE
FROM
PUM
PD
ELIVER
Y LIN
E
DRA
INLIN
E
D.G Back-up
FOOT VALVES
JOCKEY PUMP 180LPM
STAND BY PUM
P ( D.G Back-up) 2280 LPM
WATER SOURCE FROM
BORE WELL
WET RISER SYSTEM
YHYH
GL
F.ExtgrFAP
HB
HR H
V
F.ExtgrH
R HV
HB
F.ExtgrH
R HV
HB
MCP
HS
F.ExtgrH
R HV
HB
HB
HR H
V
FIRE FIGHTING W
ATER TANK 20,000 LTRS CAPACITY
TERRACE FLOOR
AIR RELEASEVALVE
BUTTERFLY VALVE
NON
RETURN VALVE
F.ExtgrH
R HV
HB
F.ExtgrH
R HV
HB
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
20.60Mtrs
Basement Floor
MCP
HS
MCP
HS
MCP
HS
MCP
HS
MCP
HS
MCP
HS
F.Extgr
PLINTH AREA(m2)
TOTAL
MAIN
BUILDING
BASEMEN
T FLOOR
GROUND FLOOR
FIRST FLOOR
THIRD FLOOR
SECOND FLOOR
FOURTH FLOOR
FIFTH FLOOR
595.20
590.20
4231.10
582.10
617.50
617.50
617.50
611.10
PLINTH
AREA STATEMEN
T