2
MORE THAN 24 HOURS OF PROTECTION WWW. HARRIS BATTERY.COM BATTERY BASED BACKUP POWER SYSTEMS HOME BACKUP POWER BUSINESS STANDBY POWER SIZING YOUR SYSTEM 22kWh 15kWh 7kWh “Utility power outages vary widely from state to state in the USA. In general, trans- mission grid outages have been doubling every 5 years due to aging infrastructure” - http://insideenergy.org Examples of Backup Systems designed to run for a 24 hour period* Energy conservation will allow for longer run times. Load switching may be required. PROTECT YOURSELF FROM AGING UTILITY INFRASTRUCTURE 1-800-367-7670 Call To Get Started Today ©Harris Battery Company Inc. All rights reserved. We attempt to ensure the correctness of the product descriptions and specifications contained herein. We reserve the right to change designs and specifications without notice or obligation. DOCUMENT PUBLISH DATE 06/12/2017 WWW. HARRIS BATTERY.COM CLEAN & SILENT FULLY AUTOMATIC MAINTENANCE-FREE Chest Freezer, 16.5 cu. ſt. energy star 1,100 watt hour Refrigerator, 22 cu. ſt. Energy Star 1,500 watt hour Sump Pump 1/3HP** 3,000 watt hour Typical fan, gas furnace blower 3,000 watt hour Well Pump, high efficiency, ½ HP** 3,000 watt hour LED lighting (5) 10W lamps 1,200 watt hour Television, 42” LCD (8 hrs) 2,240 watt hour Coffee pot 2,000 watt hour Wifi router 240 watt hour Computer/Server 3000 watt hour Phone Charging 10 watt hour *Actual run times will vary based on system design, appliance energy efficiency and usage. ** Start up demand may exceed system capacity. Refer to owner’s manual for details. NEVER LOSE POWER AGAIN TM TM
Transcript
Page 1: Battery Based Backup Power INSIDE SPREAD ENERGUARD2 copy · Computer/Server 3000 watt hour Phone ... Your Battery Based Backup System powers your designated circuits. If your power

MORE THAN 24 HOURS OF PROTECTION WWW.HARRISBATTERY.COM

BATTERY BASED BACKUP POWER SYSTEMS

HOMEBACKUPPOWER

BUSINESS STANDBYPOWER

S I Z I N G Y O U R S Y S T E M22kWh15kWh7kWh

“Utility power outages vary widely from state to state in the USA. In general, trans-mission grid outages have been doubling every 5 years due to aging infrastructure” - http://insideenergy.org

Examples of Backup Systems designed to run for a 24 hour period* Energy conservation will allow for longer run times. Load switching may be required.

PROTECT YOURSELF FROM AGING UTILITY INFRASTRUCTURE

1-800-367-7670Call To Get Started Today

©Harris Battery Company Inc. All rights reserved. We attempt to ensure the correctness of the product descriptions and specifications contained herein. We reserve the right to change designs and specifications without notice or obligation. DOCUMENT PUBLISH DATE 06/12/2017

WWW.HARRISBATTERY.COM ☑ CLEAN & SILENT ☑ FULLY AUTOMATIC ☑ MAINTENANCE-FREE

Chest Freezer, 16.5 cu. �. energy star 1,100 watt hour

Refrigerator, 22 cu. �. Energy Star 1,500 watt hour

Sump Pump 1/3HP** 3,000 watt hour

Typical fan, gas furnace blower 3,000 watt hour

Well Pump, high e�iciency, ½ HP** 3,000 watt hour

LED lighting (5) 10W lamps 1,200 watt hour

Television, 42” LCD (8 hrs) 2,240 watt hour

Co�ee pot 2,000 watt hour

Wifi router 240 watt hour

Computer/Server 3000 watt hour

Phone Charging 10 watt hour

*Actual run times will vary based on system design, appliance energy e�iciency and usage. ** Start up demand may exceed system capacity. Refer to owner’s manual for details. NEVER LOSE POWER AGAIN

TM

TM

Page 2: Battery Based Backup Power INSIDE SPREAD ENERGUARD2 copy · Computer/Server 3000 watt hour Phone ... Your Battery Based Backup System powers your designated circuits. If your power

BACK-UP WHAT IS IMPORTANT TO YOU

UTILITY POWER OUTAGES & BROWNOUTSWhen utility power is lost, your Battery Based Backup Power System automaticallydetects power outage. Power will then be supplied to the specific circuits in the sub-panel that you choose to have powered when the grid is down.

CUSTOMIZABLE, SAFE & SILENT BACKUP POWERYour Battery Based Backup System powers your designated circuits. If your power needs for current transfer capability exceed one Inverter/Charger (4000W), you can parallel multiple inverters to increase the current flow, and add additional battery storage for longer outages.

AUTOMATICALLY RECHARGES BATTERIESWhen the power is restored, your Battery Based Backup Power System provides fast and e�icient charge power technology to ensure fully charged batteries.

WWW.HARRISBATTERY.COM

☑ No Emissions ☑ No Refueling ☑ Maintenance-Free ☑ No HOA limitations

HOW IT WORKS:

1.

2.

3.

4000W INVERTER/CHARGER

AC&DC BREAKER PANELS

BATTERY CABLES

BATTERY RACK

12 x 2VRE-800TG GEL OPzV TUBULAR CELLS

7kWhBATTERY CAPACITY

4000W INVERTER/CHARGER

AC&DC BREAKER PANELS

BATTERY CABLES

BATTERY RACK

12 x 2VRE-1600TG GEL OPzV TUBULAR CELLS

15kWhBATTERY CAPACITY

4000W INVERTER/CHARGER

AC&DC BREAKER PANELS

BATTERY CABLES

BATTERY RACK

12 x 2VRE7-2300TG GEL OPzV TUBULAR CELLS

22kWhBATTERY CAPACITY

STARTCRITICAL LOADS

PROCRITICAL LOADS

+ 2x STORAGE

ULTIMATECRITICAL LOADS

+ 3x STORAGE

AVAILABLE UPGRADES:

Schneider ElectricAUTO GEN START

Schneider Electric BATTERY MONITOR

Custom engineered solutions, larger inverter/charger options and seismic rated battery racks also available.

ELIMINATES GENERATOR ISSUES:

HOMEBACKUPPOWER

BUSINESS STANDBYPOWER

PROTECT YOUR POWER SUPPLY

REFRIGERATOR/FREEZER

WIFI/ROUTER

APPLIANCES

SUMP PUMP

WELL PUMP

ENTERTAINMENT

LIGHTING & SECURITY

Schneider ElectricCOMBOX


Recommended