BATTERY CHARGING STATION„CHARGE MANAGER 2024“
OPERATING INSTRUCTIONS FOR THE SOFTWARE
VERSION 05/15
Item no.2002024
2
TABLE OF CONTENTS Page1. Functions of the „CM2024 Logger“ Software .............................................................................................................................................. 32. Installation of the „CM2024 Logger“ Software ............................................................................................................................................. 33. Getting Started ............................................................................................................................................................................................ 44. Operation of the Software ........................................................................................................................................................................... 55. Starting Charging Programmes ................................................................................................................................................................... 76. Cancelling Charging Programmes .............................................................................................................................................................. 77. Saving/Loading Recordings ........................................................................................................................................................................ 88. Use of the Windows Clipboard .................................................................................................................................................................... 89. Display Options ........................................................................................................................................................................................... 910. Operation of the Chart Function ................................................................................................................................................................ 1011. Setup „Settings“......................................................................................................................................................................................... 1212. Suspend/Contine Recordings .................................................................................................................................................................... 12
3
1. FUNCTIONS OF THE „CM2024 LOGGER“ SOFTWARE• Displayoftheselectedprogramme,thecurrentprogrammesection,therechargeablebatterychemistry,thetimeandchargingparameters,
such as voltage and charging current• Recordingtheprogressofvoltage,current,charginganddischargingcapacity,etc.• Graphicalillustrationoftheprogressesofvoltageandcurrentinchartform• Printfunctionformeasuringlogs• Saving,loading,pausingandcontinuingrecordings• ExportoftherecordeddatatoExcel(fromVersion2010orhigher)includinggenerationofvoltageandcurrentcharts• ExportoftherecordeddataasCSVfile(=„CommaSeparatedValues“)forreadingintoallcommonspreadsheetprogrammes• Inputandstartofchargingprogrammes• ImportoftherecordsfromtheSDmemorycardSystem Requirements:• WindowsoperatingsystemfromWindowsXPwithSP3orhigher• NetFrameworkV4.0(ClientProfile)• Resolutionatleast1280x768
2. INSTALLATION OF THE „CM2024 LOGGER“ SOFTWAREAftertheoperatingsystemhasbeenfullyloaded,startinstallationofthesoftwareandfollowtheinstructionsoftheinstallationprogrammeoryour operating system.
Note: Beforeconnectingthe„ChargeManager2024“tothecomputer,alwaysinstallthedriversoftware(„SiliconLabsCP210xUSB-UART
Bridge“)accordingtotheinstructionsoftheinstallationprogramme. Thelatestdriverversioncanbefoundunderhttp://www.silabs.com/products/mcu/Pages/USBtoUARTBridgeVCPDrivers.aspxAftercompletionofthesoftwareanddriverinstallation,connectthe„ChargeManagerCM2024“toafreeUSBportofyourcomputerwithasuitableconnectioncable.ThechargerhasaUSBinterfaceforthis(USB-Bsocketattherearofthedevice).Windowsrecognisesthenewhardwarewhenitisconnectedforthefirsttimeandcompletestheinstallationoftherequireddrivers.IntheWindowscontrolpanel,youcancheckinthedevicemanagerwhichCOMporthasbeenawardedtothe„ChargeManager2024“(e.g.„COM7“,seearrowinthefollowingfigure).
Now software installation has been completed.
4
3. GETTING STARTEDAtthefirststartofthesoftware,youneedtoselecttheCOMportofthe„ChargeManager2024“accordingtotheentryinthecontrolpanel(inthisexample„COM7“.
Thissettingcanbechangedunder„Settings/COM-Port“later.Afterconfirmingtheselectionwith„OK“,themainwindowofthesoftwareappears.
Byclickingthebutton„StartLogging“(upperleft),recordingofthedatawillbestarted(thebuttonswitchesitscolourfromredtogreenandthelabelswitchesto„stoplogging“).
Thechargermustbeinoperation,i.e.thedisplaylightingofthe„ChargeManager2024“ison.Toterminatedatarecording,clickthebuttonagain.Thecolourchangesbacktored(andthelabelofthebuttonbackto„StartLogging“,seeabove).
Ifnodataarerecordedbythechargerformorethanapprox.10secondsbecause,e.g.,theconnectiontothechargerhasbeendis-connected,theprogrammewillautomaticallyinterruptdatarecording.Continuationoftherecordingispossible.
5
4. OPERATION OF THE SOFTWAREView during data recording:
1 Load,saveandimportrecordingsfromcard2 SettingtheCOM-port/displaybrightness.TerminatingtherecordingontheSDmemorycard3 ExporttoExcelor„CSV-file“4 View: Chart and/or table5 Print measuring log6 Delete recording7 Automatic display of the last measured value in the table8 Display for data reception from the charger9 Display of the recorded data in table form. The data transfer to other programmes via the clipboard is supported.10 Curves of voltage and current. Different display versions can be chosen.11 Parameterdisplayofthechargingslot.Clickingselectsthecorrespondingview.Ifthedisplayhasabluebackground,thechargepro-
grammeinputisshownafterclicking.The„Stop“symbolorright-clickcancelstherunningchargeprogramme.
1 2 43 5 6 7
8 9 10 11
6
General Notes:• Therecordeddataarealwaysputininterimstorageinparalleltothedisplayinthetemporaryfilesaswell.Iftherearetemporaryfilesatprogrammestart,theprogrammeofferstocontinuetherecording.
• Whenremovingarechargeablebatteryduringtherecording,theassociatedvaluesareautomaticallydeleted.Thisensuresdataintegrity.• Theexportfunctionsfor„Excel“and„CSV“referonlytothecurrentlychosenchargingslot.• Theprintfunctionisnotavailableduringdatarecording.• Thechartsareprintedoutasshowninthesoftware.Thismeans:Ifacut-outhasbeenenlarged,theoutputtakesplaceinthisenlargedviewaswell.Insertionofatitlelineunderindicationofthebatteryslotnumber,duration,charginganddischargingcapacitytakeplaceautomatically. The recommended print format is DIN A4 or DIN A3.
• Loadingandsavingdatavia„File“->„LoadLoggedData“or„SaveLoggedData“referstothedataofallbatterychutesofthe„ChargeManager 2024“. The temporary data are overwritten in „Load Logged Data“.
• Theprogrammeensuresuninterrupteddatarecordingbydeactivatingtheenergysavingsmodeofthecomputerduringtherecording.
7
5. STARTING CHARGING PROGRAMMES
Ifoneorseveralrechargeablebatteriesareinserted,theparameterdisplayshows„NoSetup“.Theparametersetupofthebatteryslotwhereprogrammeinputispossibleisdisplayedinblue.Afterclickingtheparameterdisplay,thechar-ge programme input is now displayed. The parameters suggested by the charger are displayed and can now be changed. Afterclicking„Start“,thechargingprogrammeisexecuted.
Ifthechargingprogrammeisstartedatthechargerinthemeantime,itwillbeexecutedwiththeparameterschosenatthecharger.Then the active programme input in the PC software is concealed after starting.
6. CANCELLING CHARGING PROGRAMMES
Thecurrentprogrammeofthechargingslotcanbecancelledviatherespective„stop“symbolorbyrightclickonthebatteryslotdisplayandthefinalconfirmationof„CancelProgramofSlotx“.
8
7. SAVING/LOADING RECORDINGS
ThechargecurvescanbesavedontheSDmemorycardand/orthePC(„SaveLoggedData“). WhensavingonthePC,itmustbecontinuallyconnectedtothechargerandtherecording(„Logging“)mustbeactive.
IfthechargingcurveshavebeenrecordedontheSDmemorycard,thedatacanonlybereadviaacardreaderatthePCsubsequently(„ImportLogFilefromSDCard“).Itisalsopossibletoloadthesavedrecordsagainwiththissoftware(„LoadLoggedData“).
8. USE OF THE WINDOWS CLIPBOARDInadditiontotheexportfunction,thereisalsotheoptionofexportingtherecordeddataviatheWindowsclipboardintoanyspreadsheetprogrammes,suchas„LibreOffice/OpenOffice“.Procedure:1. Selecttherequiredcellsinthetable2. Right-clickingthetableshowsthefollowingdialogue: „Copy To Clipboard“ copies the selected area or „Copy All...“ copies the entire active table
into the clipboard. Alternatively,thereisalsotheoptionofsavingselecteddataby„CTRL+C“(Copy).3. Thesedatacanbedirectlytransmittedtothetargettableby„CTRL+V“(insert).
9
9. DISPLAY OPTIONSUnder„DisplayStyle“,youcanselecttherequireddisplay.If„Table“isselected,onlythedataintableformareshown;whenselecting„Charts“,theillustrationofthecurvesforvoltageandcurrentingraphicformisactive.There is also the option of concurrent display of both versions.Example: Display version „Charts“
Discharge Charging Cooling pause
Final voltage
Whether charging or discharging is currently underway is shown by colour:• Greenandred:Duringthechargingphases• Darkgreenandbrown:Duringthedischargingphases• Blueandorange:Coolingphasesinthe„Maximize“programme
Missingdatapoints(e.g.duetorecordingpauses)aremarkedbygreydots.Attheendoftheprogramme,thechartalsoindicatesthefinalvoltage.
10
10. OPERATION OF THE CHART FUNCTIONFunctions:Fourviewsarepossible:Line,bar,areachartandlinesin3Dperspective(„Tilt“and„Rotation“canbeset).
Line chart Bar chart
Areachart 3D-lines
11
Enlarging to certain areas, „Zoom“ by mouse:Keeptheleftmousebuttonpushedinthegraphicaldisplayanddrawaframeoverthedesiredarea.Afterreleasingthemousebutton,theselected area is shown enlarged.
Alternative: Movethemousepointertotheareaofthechartandright-click.Thefollowinginputfieldappears(seefigureontheright).• „ZoomIn“enlargestheviewbyhalfoftherecording.• „ResetZoom“takesyoubacktotheoverallview.
Dependingonthepointerpositionofthemouse,youcanalsousethescrollwheeltoenlarge/reduce.
Moving the displayed areas Movementispossibleviathecursorbuttonsonthekeyboard(arrows)orthescrollbarsatthechartwindows.
Further control options via the keyboardButton Function„Home“(„Pos1“) Restoretotalview(like„ResetZoom“)„Delete“(„Entf“/„Del“) Jumptothestartoftherecording„End“(„Ende“) Jumptotheendoftherecording„“(„Backspace“) Reducezoombyonelevel„PageUp“(„Bild“) MoveX-axistowardstheendinlargesteps„PageDown“(„Bild“) MoveX-axistowardsthestartinlargesteps
Display of the data on the mouse pointer positionIfthemousepointerisplacedononeofthedisplayedcurves,pushingtherightmousebuttonwill return the current values at this time.
12
11. SETUP „SETTINGS“
„COMPort“: SelectionoftheCOM-port(onlypossiblewhennorecordingisrunning)„LCDbrightness“: Settingthedisplaybrightnessofthe„ChargeManager2024“(onlypossiblewhentherecordingisrunning)„ReleaseSD-Card“: TerminaterecordingontheSD-memorycard(onlypossiblewhenarecordingisrunning)
12. SUSPEND/CONTINUE RECORDINGSAfterdisconnectingthemainsunitofthecharger,thefollowingmessagewillbedisplayedbythesoftwareafterapprox.10seconds:
Nowclosethesoftware.Ifrequired,thecomputercannowbeswitchedoff.Thesoftwarewilloffertocontinuetherecordingatthenextprogrammestart.
Youcannowtakethechargerintooperationagainandthenconfirmthesoftwaremessagewith„Yes“.Nowthelastrecordeddataareloadedand the recordings are automatically continued. Whenselecting„no“,thedataaredeletedandanewrecordingisstarted.
Ifthesoftwarehasnotbeenterminated,pushthebutton„StartLogging“aftertakingthe„ChargeManager2024“intooperation.Therecording is continued here as well.
( Legal NoticeThisisapublicationbyConradElectronicSE,Klaus-Conrad-Str.1,D-92240Hirschau(www.conrad.com).
Allrightsincludingtranslationreserved.Reproductionbyanymethod,e.g.photocopy,microfilming,orthecaptureinelectronicdataprocessingsystemsrequirethepriorwrittenapprovalbytheeditor.Reprinting,alsoinpart,isprohibited.Thispublicationrepresentthe technical status at the time of printing.
© Copyright 2015 by Conrad Electronic SE. V1_0515_01_DT