+ All Categories
Home > Documents > BC-TSG - tetisantesisat.com Dwyer - Temperature.pdfHigh/Low limit alarm Thermocouple, RTD, current...

BC-TSG - tetisantesisat.com Dwyer - Temperature.pdfHigh/Low limit alarm Thermocouple, RTD, current...

Date post: 29-Sep-2018
Category:
Upload: phungdang
View: 217 times
Download: 0 times
Share this document with a friend
4
BC-TSG
Transcript

DWYER INSTRUMENTS, INC.

BC-TSG

PROGRAMMABLE SWITCHES

TS2

INDICATORS

Modbus® is a registered trademark of Schnieder Automationwww.love-controls.com www.love-controls.comwww.love-controls.com

LIMIT SWITCHES

Series

TEMPERATURE

TS TCS TSS2 TSX TSWB TSF 16L TID TI

CONTROLLERS

32ASeries

TEMPERATURE

32B 32DZ 16A 16B 16C 2600 4B SCD SCZ

Range

Control TypeInput

Output

Horsepower RatingPower Requirements

Accuracy

DisplayFeaturesFront Panel RatingAgency Approvals

-50 to 150°C (-58 to 302°F)

On/Off, Heat/CoolPTC thermistor 1000Ω @ 25°C

16A SPDT relay @ 250 VAC resistive5A inductive

1 HP @ 240 VAC110 VAC, 230 VAC, 12 VDC/AC,

24 VDC/AC

±1°C

3 digit, red, 1/2˝ digitsEasy multi-unit programming

IP64

-50 to 150°C (-58 to 302°F)

On/Off, Heat/CoolPTC thermistor 1000Ω @ 25°C

16A SPDT relay @ 250 VAC resistive5A inductive

1 HP @ 240 VAC110 VAC, 230 VAC, 12 VDC/AC,

±1°C

3 digit, red, 1/2˝ digitsPolycarbonate key pad, probe included

IP64

0 to 700°C (32 to 999°F) for Jthermocouple; 0 to 999°C (32 to999°F) for K and S thermocouple

On/Off, Heat/CoolType J, K or S thermocouple

16A SPDT relay @ 250 VAC resistive5A inductive

1 HP @ 240 VAC110 VAC, 230 VAC, 12 VDC/AC,

24 VDC/AC

±1°C

3 digit, red, 1/2˝ digitsEasy, multi-unit programming

IP64

-50 to 150°C (-58 to 302°F)

On/Off, Heat/CoolPTC thermistor 1000Ω @ 25°C

8A SPDT relay @ 250 VAC16A SPDT relay @ 250 VAC

1 HP @ 240 VAC110 VAC, 230 VAC, 12 VDC/AC,

24 VDC/AC

±1°C

3 digit, red, 1/2˝ digitsDual stage temperature control

IP64

PTC: -50 to 150°C (-58 to 302°F);NTC: -50 to 110°C (-58 to 230°F)

On/Off, Heat/CoolNTC/PTC thermistor 1000Ω @ 25°C

One 16A SPST relay @ 250 VACresistive; One 5A SPDT relay @ 250VAC resistive; One 3A SPST relay @

250 VAC resistive1 HP @ 240 VAC for 16A relay110 VAC, 230 VAC, 12 VDC/AC,

24 VDC/AC

±1°C

3 digit, red, 1/2˝ digitsUp to 3 outputs and inputs

IP64

-50 to 150°C (-58 to 302°F)

On/Off, Heat/CoolPTC thermistor 1000Ω @ 25°C

One 16A @ 250 VAC; Two 5A @ 250VAC

1 HP @ 240 VAC for 16A relay110 VAC, 230 VAC, 12 VDC/AC,

24 VDC/AC

±1°C

3 digit, red, 1/2˝ digits3 relay outputs, water level input

IP64

0 to 700°C (32 to 999°F) for Jthermocouple; 0 to 999°C (32 to999°F) for K and S thermocouple

High/Low limit alarmType J, K or S thermocouple

One 16A SPDT relay @ 250 VACresistive, 5A inductive

1 HP @ 240 VAC110 VAC, 230 VAC, 12 VDC/AC,

24 VDC/AC

±1°C

3 digit, red, 1/2˝ digitsLocal or remote manual reset

IP64

-73 to 1300°C (-100 to 2372°F)

High/Low limit alarmThermocouple, RTD, current or voltage

Up to 2 3A SPST relays @ 240 VACresistive, 1.5A @ 240 VAC inductive

––100 to 240 VAC, 132 to 240 VDC

±0.25% of span, ±1 least significantdigit

Two 4 digit displays, 7.62 mm (0.3˝)Universal input, fits 1/16 DIN cut out

IP65

-99 to 999 counts

––Current, PTC or NTC thermistor 1000Ω

@ 25°C (depending on model)––

––110 VAC, 230 VAC, 12 VDC/AC,

24 VDC/AC

±1°C

3 digit, 1/2˝ digitsOutputs 12 VAC supply voltage

IP64

-50 to 99°C (-58 to 99°F)

––PTC thermistor 1000Ω @ 25°C

––

––110 VAC or 230 VAC

(depending on model)

±1°C

2 digit plus sign, red, 1/2˝ digitsLarge red display

IP64

SizeControl TypeInput

Output

Power RequirementsAccuracy

Display

Features

Front Panel RatingAgency Approvals

1/32 DINPID, On/Off

Thermocouple, RTD, DC voltage orDC current (selectable)

AC or DC SSR, 3A SPST relay, 0 to 20mA or 5 VDC switched voltage

(depending on model)100 to 240 VAC, 132 to 240 VDC

±0.25% of span;±1 least significant digitTwo 4 digit, 7 segment,6.35 mm (0.25˝) LED’s

Fuzzy logic, illuminated keypad

IP66

1/32 DINPID, On/Off

Thermocouple, RTD, DC voltage orDC current (selectable)

5A SPST relay, 0(4) to 20 mA or 14 VDC switched voltage

(depending on model)100 to 240 VAC±0.25% of span;

±1 least significant digitTwo 4 digit, 7 segment, 6.35 mm (0.25˝) LED’s

64 step ramp & soak, RS-485Modbus® communications

IP66

1/32 DINPID, On/Off

Thermocouple, RTD, DC voltage or DC current (depending on model)

AC or DC SSR, 3A SPST relay, 0 to 20 mA or 5 VDC switched voltage

(depending on model)100 to 240 VAC, 132 to 240 VDC

±0.25% of span; ±1 least significant digitTwo 4 digit, 7 segment, 6.35 mm (0.25˝) LED’s

Independent dual zone control

IP66

1/16 DINPID, On/Off

Thermocouple, RTD, DC voltage or DC current (selectable)

AC or DC SSR, 3A SPST relay, 0 to 20 mA or 15 VDC switched voltage

(depending on model)100 to 240 VAC, 132 to 240 VDC

±0.25% of span; ±1 least significant digit

Two 4 digit,7.62 mm (0.3˝) LED’s

Optional process signal outputremote set point

IP66

1/16 DINPID, On/Off

Thermocouple, RTD, DC voltage or DC current (selectable)

5A SPST relay, 0(4) to 20 mA or 14 VDC switched voltage

(depending on model)100 to 240 VAC±0.25% of span;

±1 least significant digitTwo 4 digit, 7 segment, 6.35 mm (0.25˝) LED’s

RS-485 Modbus® communications,optional CT input

IP66

1/16 DINPID, On/Off

Thermocouple or RTD (selectable)

5A SPST relay, 0(4) to 20 mA or 14 VDC switched voltage

(depending on model)100 to 240 VAC±0.25% of span;

±1 least significant digitTwo 4 digit, 7 segment, 6.35 mm (0.25˝) LED’s

Auto-tuning, RS-485 Modbus®

communicationIP66

1/4 DINPID, On/Off

Thermocouple, RTD, DC voltage or DC current (selectable)

AC SSR, 10A SPST relay or 0 to 20 mA

(depending on model)100 to 240 VAC, 132 to 240 VDC

±0.25% of span; ±1 least significant digitTwo 4 digit, 7 segment, 14.2 mm (0.56˝) LED’s

Built-in 24V power supply, fuzzy logic

IP66

1/4 DINPID, On/Off

Thermocouple, RTD, DC voltage or DC current (selectable)

5A SPST relay, 0(4) to 20 mA, 0 to 10VDC or 14 VDC switched voltage

(depending on model)100 to 240 VAC±0.25% of span;

±1 least significant digitTwo 4 digit, 7 segment, 19 mm (0.75˝) LED’s

RS-485 Modbus® communications,optional CT input

IP66

––PID, On/Off

Thermocouple, RTD, DC voltage or DC current (selectable)

3A SPST relay, 0(4) to 20 mA, 0 to 10VDC or 12 VDC switched voltage

(depending on model)24 VDC

––

––

Up to 8 independent PID loops

––

––PID, On/Off

Thermocouple, RTD, DC voltage or DC current (selectable)

3A SPST relay, 4 to 20 mA or 12 VDC switched voltage

(depending on model)120 to 240 VAC, 24 VAC/DC

±0.25% of span; ±1 least significant digitTwo 4 digit, 7 segment, 7.5 mm (0.295˝) LED’s

Local indication and can mount to DIN rail

––

TempSG:dom/intlhumidity/temp 12/17/09 2:29 PM Page 1

Address:Dwyer Instruments, Inc.102 Indiana Highway 212P.O. Box 373Michigan City, IN 46361 U.S.A.

e-mail:General: [email protected]: [email protected]: [email protected]: [email protected]

Telephone:(800) 872-9141(219) 879-8000

website:www.dwyer-inst.comwww.love-controls.comwww.mercoid.comwww.proximitycontrols.com

Fax:(219) 872-9057

DWYER INSTRUMENTS, INC.P.O. Box 373Michigan City, IN 46361-9986

Return Service Requested

DWYER INSTRUMENTS, INC.P.O. Box 373Michigan City, IN 46361Phone: 219/879-8000Fax: 219/872-9057

Internet: http://www.dwyer-inst.comhttp://www.love-controls.com

e-mail: [email protected]

Dwyer Instruments LtdUnit 16, The Wye Estate, London RoadHigh Wycombe, Bucks HP11 1LH United KingdomPhone: (+44) (0)1494-461707Fax: (+44) (0)1494-465102

Houston Office:Phone: 281/446-1146Fax: 281/446-0696

Dwyer Instruments, Pty. Ltd.Unit 1, 11 Waverley DriveUnanderra, NSW 2526 AustraliaPhone: 61 2 4272-2055Fax: 61 2 4272-4055

Just circle any cover(s) above, photocopy this entire page (complete with your name and mailing address) and FAX it to (219) 872-9057 or e-mail us at [email protected].

Branch Office/Stocking Warehouse LocationCorporate Headquarters

A word on our Temperature Brochure...

Love Controls has and continues to be a leadingmanufacturer and innovator in industrial

temperature controls and switches. Loveoffers controllers and switches in a varietyof configurations and feature sets to solveyour most demanding applications.

Love is proud to complement thisextensive line with its new Series TSF FMApproved Limit Control and Series SCDDIN Rail Mount Temperature/ProcessController. The Series TSF is capable ofbeing a high or low limit on a variety ofapplications such as commercial waterboilers and ovens. The control can be

manually reset either through the frontpanel or a remote reset button. The Series

SCD is capable of controlling up to 8 PIDloops by connecting slave controls to the

master controls. It is programmed via RS-485Modbus® Serial Communications.

We have always felt that the best does not have tocost you the most, and encourage you, the customer, to

check out our value and what we believe to be the mostcompetitively priced products on the market.

Sincerely, The Love Controls Team

BC-TSG

DwyerCompleteCatalog

Engineeringand

ApplicationsHandbook

MercoidComplete Catalog

BuildingAutomation

SystemsCatalog

LoveControlsCatalog

ProximityControlsCatalog

IndustrialGages

Catalog

FREE!! LATEST CATALOG EDITIONS ARE NOW AVAILABLE!

©Copyright 2008 Dwyer Instruments, Inc. 9/08 Printed in U.S.A.

TempSG:dom/intlhumidity/temp 12/17/09 2:31 PM Page 2

Address:Dwyer Instruments, Inc.102 Indiana Highway 212P.O. Box 373Michigan City, IN 46361 U.S.A.

e-mail:General: [email protected]: [email protected]: [email protected]: [email protected]

Telephone:(800) 872-9141(219) 879-8000

website:www.dwyer-inst.comwww.love-controls.comwww.mercoid.comwww.proximitycontrols.com

Fax:(219) 872-9057

DWYER INSTRUMENTS, INC.P.O. Box 373Michigan City, IN 46361-9986

Return Service Requested

DWYER INSTRUMENTS, INC.P.O. Box 373Michigan City, IN 46361Phone: 219/879-8000Fax: 219/872-9057

Internet: http://www.dwyer-inst.comhttp://www.love-controls.com

e-mail: [email protected]

Dwyer Instruments LtdUnit 16, The Wye Estate, London RoadHigh Wycombe, Bucks HP11 1LH United KingdomPhone: (+44) (0)1494-461707Fax: (+44) (0)1494-465102

Houston Office:Phone: 281/446-1146Fax: 281/446-0696

Dwyer Instruments, Pty. Ltd.Unit 1, 11 Waverley DriveUnanderra, NSW 2526 AustraliaPhone: 61 2 4272-2055Fax: 61 2 4272-4055

Just circle any cover(s) above, photocopy this entire page (complete with your name and mailing address) and FAX it to (219) 872-9057 or e-mail us at [email protected].

Branch Office/Stocking Warehouse LocationCorporate Headquarters

A word on our Temperature Brochure...

Love Controls has and continues to be a leadingmanufacturer and innovator in industrial

temperature controls and switches. Loveoffers controllers and switches in a varietyof configurations and feature sets to solveyour most demanding applications.

Love is proud to complement thisextensive line with its new Series TSF FMApproved Limit Control and Series SCDDIN Rail Mount Temperature/ProcessController. The Series TSF is capable ofbeing a high or low limit on a variety ofapplications such as commercial waterboilers and ovens. The control can be

manually reset either through the frontpanel or a remote reset button. The Series

SCD is capable of controlling up to 8 PIDloops by connecting slave controls to the

master controls. It is programmed via RS-485Modbus® Serial Communications.

We have always felt that the best does not have tocost you the most, and encourage you, the customer, to

check out our value and what we believe to be the mostcompetitively priced products on the market.

Sincerely, The Love Controls Team

BC-TSG

DwyerCompleteCatalog

Engineeringand

ApplicationsHandbook

MercoidComplete Catalog

BuildingAutomation

SystemsCatalog

LoveControlsCatalog

ProximityControlsCatalog

IndustrialGages

Catalog

FREE!! LATEST CATALOG EDITIONS ARE NOW AVAILABLE!

©Copyright 2008 Dwyer Instruments, Inc. 9/08 Printed in U.S.A.