1 INVACARE ® G-SERIES BED DEPARTMENT OF VA NATIONAL CONTRACT #VA797N-14-C-0015
Transcript
Page 1: BED DEPARTMENT OF VA NATIONAL CONTRACT #VA797N-14-C … · department of va national contract #va797n-14-c-0015 16-037VA VA G-Bed Series Brochure.indd 1 4/28/16 1:15 PM INVACARE’S

1

I N VAC A R E ®

G - S E R I E S B E D

D E PA R T M E N T O F VA N AT I O N A L C O N T R AC T # VA 7 9 7 N - 14 - C - 0 015

16-037VA VA G-Bed Series Brochure.indd 1 4/28/16 1:15 PM

Page 2: BED DEPARTMENT OF VA NATIONAL CONTRACT #VA797N-14-C … · department of va national contract #va797n-14-c-0015 16-037VA VA G-Bed Series Brochure.indd 1 4/28/16 1:15 PM INVACARE’S

INVACARE’S G SERIES BED DELIVERS NEW AND INNOVATIVE FEATURES THAT FURTHER MEET PATIENTS’ NEEDS.

The Invacare G Series Bed complies with the IEC 60601-2-52 (2009) standard for safety and

essential performance of medical beds. With Invacare’s G Series Bed you will have the peace

of mind that your bed frame, mattress and rails have passed stringent tests to ensure the

highest standard for patient safety in the homecare environment.

SUPPORTIVE SLEEP SURFACEThe slat deck is designed to provide a comfortable sleep surface for patients, reduces wear and tear on the mattress and is simple to clean, allowing for improved infection control.

NEWLY DESIGNED HAND PENDANT Redesigned pendant complies with IEC 60601-2-52, Invacare’s hand pendant provides safety and durability. The pendant is ergonomically designed and fluid proof, with an extended heavy duty strain relief for increased flexibility.

INTERCHANGEABLE BED ENDS Elongated design to meet the extensive travel range to comply with the IEC 60601-2-52 standard. Easy to clean and impact resistant.

I N VAC A R E ®

G S E R I E S B E D

2

16-037VA VA G-Bed Series Brochure.indd 2 4/28/16 1:15 PM

Page 3: BED DEPARTMENT OF VA NATIONAL CONTRACT #VA797N-14-C … · department of va national contract #va797n-14-c-0015 16-037VA VA G-Bed Series Brochure.indd 1 4/28/16 1:15 PM INVACARE’S

SIMPLIFIED SET-UPThe slat deck eliminates the need to connect the springs at the middle of the bed and provides delivery technicians with top down accessibility to key components.

SECURE MATTRESS KEEPERSInvacare’s mattress keepers enhance patient safety by securely positioning the mattress to prevent sliding.

IP66 RATINGWater resistant connections to prevent fluid ingress. Increased infection control with fluid resistant, washable electronics for efficient cleaning and complies with IEC 60601-2-52.

ADVANCED ELECTRONIC FEATURESPendant connects on either side of the bed for patient’s

ease of use. Three motors operate bed sections

independently. Tool-less replacement of motors.

CRANK THROUGH ELECTRONICSDesigned to allow all motors to be operated manually in the event of a power outage.

BED FEATURES

ERGONOMIC BED SECTIONSErgonomically designed head and foot sections with elongated head section for increased patient comfort.

3

16-037VA VA G-Bed Series Brochure.indd 3 4/28/16 1:15 PM

Page 4: BED DEPARTMENT OF VA NATIONAL CONTRACT #VA797N-14-C … · department of va national contract #va797n-14-c-0015 16-037VA VA G-Bed Series Brochure.indd 1 4/28/16 1:15 PM INVACARE’S

Model # Dimensions Sleep Weight Shipping Carton Regulation Limited Surface Capacity Weight Dimensions Compliance Warranty

G5510 36" W 36" W Safe Working Load: N/A N/A IEC 60601-2-52 (2009) 2 Years 88" L 80" L 450 lb.* IEC 60601-1-11 (2011) (Electronics 15"-32" Max. Patient Weight: IP66 & Mechanical) (travel range) 350 lb. ANSI/AAMI 5 Years 60601-1 3rd Ed. (Welds)

G50 Headspring 36"W x45"L x 8"H 44 lb. 47" x 8" x 36" 2 Years Mechanical 5 Years Welds

G54 Footspring 36"W x 37.5"L x 8"H 68 lb. 47" x 9" x 37" 2 Years Mechanical 5 Years Welds

G53 Bed Ends 39"W x 7"L x 33"H 60 lb. 39" x 7" x 34" 2 Years Mechanical 5 Years Welds

All references to HCPCS codes: Providers are responsible for determining the appropriate billing codes when submitting claims to the Medicare program, and should consult an attorney or other advisor to discuss specific situations in further detail.

** Whenever bed rails are used as part of any hospital or homecare bed system, the potential for bed rail entrapment exists. To reduce this risk, a patient must always be assessed regarding their risk of entrapment before any product is used. Routine patient monitoring is also required once a product is in use. To learn more about the risk of bed rail entrapment please visit the US FDA’s website at http://www.fda.gov and search for “Bed Rail Entrapment.”

*Includes patient, mattress and all accessories.

Design factors for the IEC 60601-2-52 bed standard

Introducing the latest design in hospital beds from Invacare. The Invacare® G-Series bed meets the current international standard for safety and performance in hospital beds, IEC 60601-2-52 (2009).

Included in the standard are a number of noteworthy design factors such as the following:

Extensive Travel Range Hospital beds intended for use in a home environment must have a travel range of least 15.75" – 31.5" (40 cm-80 cm)

Improved Mattress Support Platform

Head section of the mattress support platform was lengthened to improve patient comfort and support while meeting the angle requirements of the standardsKnee section of the mattress support platform was modified to provide a more ergonomic design and better comfort under knee

Mattress Retention System

Holds the mattress in place reducing the chance of it sliding off the bed during patient ingress or egress when rails are not in use

Pinch Point Mitigation Bed deck redesigned to mitigate risk of pinching by such means as moving susceptible parts in 8" from edge of bed

Improved Patient Entrapment Mitigation

Gap from head board to rail must be less than 60 mmGap from foot board to rail must be less than 60 mm or greater than 318 mmGap between split rails must be greater than 318 mm Top of rails must be at least 8.7" (220 mm) above mattress

Patient Control Pendant Increased button size to improve patients’ ease of use Symbols were redesigned to more user-friendly designs

Enhanced Stability Test 4 locking casters to aid in bed stability

Labeling Mattress, rail, patient weight and safe working load

Trapeze Must be able to hold 168 lb. and still maintain shape

4

16-037VA VA G-Bed Series Brochure.indd 4 4/28/16 1:16 PM

Page 5: BED DEPARTMENT OF VA NATIONAL CONTRACT #VA797N-14-C … · department of va national contract #va797n-14-c-0015 16-037VA VA G-Bed Series Brochure.indd 1 4/28/16 1:15 PM INVACARE’S

Invacare® Half-Length Rail

Model # G30

Exclusive to the Invacare G-Series beds

• Meets IEC 60601-2-52 requirements (2009)

• Removable installation brackets

• Durable powder coated finish resists scratching

• Ships as a pair

The Invacare G30 half-length bed rail meets the latest standard for patient safety, IEC 60601-2-52 (2009). The G30 rail features sturdy, one-inch diameter tubing and includes a rigid cross brace that provides enhanced strength and durability for added protection from entrapment risks. Bed rails, when properly used, are an important safety and accident prevention accessory. The G30 half-length rail is ideal for patients who need assistance in repositioning while in the bed.

Invacare beds, mattresses and rails, excluding therapeutic support surfaces and bariatric beds, when used as a system and sold new and unused after August 1, 2007, meet the voluntary FDA Guidelines for bed rail entrapment. Visit www.invacare.com/bedsafety for additional safety and entrapment information.

HCPCS Code: E0305**

HMESA CODE: 10-10-01-01

Invacare® Full-Length Bed Rail

Model # G29

Exclusive to the Invacare G-Series beds

• Meets IEC 60601-2-52 requirements (2009)

• Removable installation brackets

• Durable powder coated finish resists scratching

• Ships as a pair

The Invacare G29 full-length bed rail meets the latest standard for patient safety, IEC 60601-2-52 (2009). The G29 rail features sturdy, one-inch diameter tubing and bolts directly to the frame of the G-Series bed providing enhanced strength and durability for added protection from entrapment risks. Bed rails, when properly used, are an important safety and accident prevention accessory. The G29 full-length rail is ideal for patients who are at risk of rolling out of the bed.

Invacare beds, mattresses and rails, excluding therapeutic support surfaces and bariatric beds, when used as a system and sold new and unused after August 1, 2007, meet the voluntary FDA Guidelines for bed rail entrapment. Visit www.invacare.com/bedsafety for additional safety and entrapment information.

HCPCS Code: E0310**

HMESA CODE: 10-10-01-02

All references to HCPCS codes: Providers are responsible for determining the appropriate billing codes when submitting claims to the Medicare program, and should consult an attorney or other advisor to discuss specific situations in further detail.

** Whenever bed rails are used as part of any hospital or homecare bed system, the potential for bed rail entrapment exists. To reduce this risk, a patient must always be assessed regarding their risk of entrapment before any product is used. Routine patient monitoring is also required once a product is in use. To learn more about the risk of bed rail entrapment please visit the US FDA’s website at http://www.fda.gov and search for “Bed Rail Entrapment.”

Model # Rail Length* Rail Height Rail Height Limited Above Deck Above Deck Warranty Raised Lowered

G29 Full-Length Rail 64.8" 15.5" 4.7" 1 Year

G30 Half-Length Rail 32" 16.2" Below the deck 1 Year

*Measurement on flat bed as per owner's manual.

FEATURES FEATURES

5

16-037VA VA G-Bed Series Brochure.indd 5 4/28/16 1:16 PM

Page 6: BED DEPARTMENT OF VA NATIONAL CONTRACT #VA797N-14-C … · department of va national contract #va797n-14-c-0015 16-037VA VA G-Bed Series Brochure.indd 1 4/28/16 1:15 PM INVACARE’S

Invacare® Trapeze

Model # G7740CS

• Ideally centered directly over the patient for ease of use

• Soft grip handle easily adjusts in height

• Attaches directly to the bed end

• Durable powder coated finish resists scratching

• Meets IEC 60601-2-52 (2009) requirements

The G7740CS patient trapeze helps the patient reposition while they are in bed. Ideally positioned directly over the center of the bed, the patient simply grabs the height adjustable, soft grip handle to reposition themselves. The G770CS trapeze meets the requirements of the IEC 60601-2-52 (2009) standard and is appropriate for patients using the G5510 bed.

HCPCS Code: E0910**

HMESA CODE: 10-10-07-00

Model # Height Range User Limited Weight Warranty

G7740CS Trapeze 20" - 28" 168 lb. 1 Year Mattress (safe working to Trapeze load)

FEATURES

All references to HCPCS codes: Providers are responsible for determining the appropriate billing codes when submitting claims to the Medicare program, and should consult an attorney or other advisor to discuss specific situations in further detail.

** Whenever bed rails are used as part of any hospital or homecare bed system, the potential for bed rail entrapment exists. To reduce this risk, a patient must always be assessed regarding their risk of entrapment before any product is used. Routine patient monitoring is also required once a product is in use. To learn more about the risk of bed rail entrapment please visit the US FDA’s website at http://www.fda.gov and search for “Bed Rail Entrapment.”6

16-037VA VA G-Bed Series Brochure.indd 6 4/28/16 1:16 PM

Page 7: BED DEPARTMENT OF VA NATIONAL CONTRACT #VA797N-14-C … · department of va national contract #va797n-14-c-0015 16-037VA VA G-Bed Series Brochure.indd 1 4/28/16 1:15 PM INVACARE’S

Invacare® Solace Prevention Mattress, 80" L

Model # SPS1080

• Nylon top cover and tri-laminate vinyl bottom for ease in cleaning and durability

• Two layer, high quality foam designed for preventing pressure ulcers

• Aids in providing uniform weight distribution for pressure ulcer prevention

Featuring special zoned layers of high density foam for aid in pressure relief on areas susceptible to pressure ulcers and soft head and foot sections for ultimate comfort, this dual-layered mattress has the comfort and technology that users need.

HCPCS Code: E0184**

HMESA CODE: 10-10-08-01

SPS 1080.fsa Bed

Report created by FSA - www.pressuremapping.com

1

Female5' 5" 110 lbs

Friday, September 18, 2009 3:36:13.281 PM

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

mmHg

1. Test shows subject in supine position demonstrating contact measurement between key pressure points using FSA pressure mapping technology. Subject: Female, 5'2", 105 lb.

Model # Dimensions Weight Regulation Limited Capacity Compliance Warranty

SPS1080 80" L 350 lb. 16 CFR 1632 5 Years 36" W 16 CFR 1633 (Mattress) 6" H 1 Year (Cover)

1

FEATURES

All references to HCPCS codes: Providers are responsible for determining the appropriate billing codes when submitting claims to the Medicare program, and should consult an attorney or other advisor to discuss specific situations in further detail.

** Whenever bed rails are used as part of any hospital or homecare bed system, the potential for bed rail entrapment exists. To reduce this risk, a patient must always be assessed regarding their risk of entrapment before any product is used. Routine patient monitoring is also required once a product is in use. To learn more about the risk of bed rail entrapment please visit the US FDA’s website at http://www.fda.gov and search for “Bed Rail Entrapment.” 7

16-037VA VA G-Bed Series Brochure.indd 7 4/28/16 1:16 PM

Page 8: BED DEPARTMENT OF VA NATIONAL CONTRACT #VA797N-14-C … · department of va national contract #va797n-14-c-0015 16-037VA VA G-Bed Series Brochure.indd 1 4/28/16 1:15 PM INVACARE’S

Invacare Corporation www.invacare.com

USAOne Invacare WayElyria, Ohio44035-4190(800) 333-6900

©2016 Invacare Corporation. All rights reserved. Trademarks are identified by the symbols ™ and ®. All trademarks are owned by or licensed to Invacare Corporation unless otherwise noted. Specifications are subject to change without notification. Form No. 16-037va160153

* When used as part of any homecare bed system, the international standard is put in place to ensure patient safety and durability of all medical beds. Key elements include differentiation by application environment, changes in the gaps and clearances of side rails to minimize entrapment (calculated using the 5th percentile of an adult female head, neck and chest dimensions), increased durability of side rails, enhanced safety instructions and warning labels.

** Whenever bed rails are used as part of any hospital or homecare bed system, the potential for bed rail entrapment exists. To reduce this risk, a patient must always be assessed regarding their risk of entrapment before any product is used. Routine patient monitoring is also required once a product is in use. To learn more about the risk of bed rail entrapment please visit the US FDA’s website at http://www.fda.gov and search for “Bed Rail Entrapment.”

Kits and Components

Invacare Model # HCPCS Description

GBED-56 Invacare® G-Series Bed Package includes G5510 Full-Electric Bed and one set of G29 Full Rails. (mattress not included)

GBED-57 Invacare® G-Series Bed Package includes G5510 Full-Electric Bed and one set of G30 Half Rails. (mattress not included)

GBED-58 Invacare® G-Series Bed Package includes G5510 Full-Electric Bed and two sets of G30 Half Rails. (mattress not included)

G5510 Hospital Bed, Total Electric

G29 Bed side rails, full length

G30 Bed side rails, half length

G7740CS Trapeze

SPS1080 Solace Foam Pressure Reduction Mattress

DEPARTMENT OF VA NATIONAL CONTRACT #VA797N-14-C-0015

TO PLACE YOUR ORDER CALL: 1.800.642.8262

8