BIEL-029 No. of Printed Pages : 5
DIPLOMA - VIEP - ELECTRONICS AND COMMUNICATION ENGINEERING (DECVI) /
ADVANCED LEVEL CERTIFICATE COURSE IN ELECTRONICS AND COMMUNICATION
ENGINEERING (ACECVI)
Term-End Examination
June, 2017
BIEL-029 : ELECTRONIC MEASUREMENT AND INSTRUMENTS
Time : 2 hours Maximum Marks : 70
Note : Attempt five questions in all. Question no. 1 is
compulsory. All questions carry equal marks.
Missing data, if any, may be assumed. Use of
scientific calculator is allowed.
1. Choose the correct answer from the four
alternatives : 7x2=14
(a) Errors due to human mistakes are called
(i) Systematic Errors
(ii) Instrument Errors
(iii) Gross Errors
(iv) Environmental Errors
BI EL-029
1 P.T.O.
(b) Moving iron and PMMC instruments can be distinguished from each other by looking at the
(i) Pointer
(ii) Terminal Size
(iii) Scale
(iv) Scale Range
(c) Which type of method of focusing is used by CRT in CRO ?
(i) Electrostatic
(ii) Electromagnetic
(iii) Electromechanical
(iv) None of the above
(d) A digital voltmeter uses an A/D converter which needs a start pulse, uses an analog comparator and has a relatively fixed conversion time independent of the applied voltage. The A/D converter is
(i) a Successive Approximation Converter
(ii) a Digital Ramp Converter
(iii) a Dual Slope Converter
(iv) All the above
(e) In CRO, which of the following is not a part of the electron gun ?
(i) Cathode
(ii) Grid
(iii) Accelerating plates
(iv) X-Y plates
BIEL-029 2
(f) A spring controlled moving iron instrument
exhibits a square law response resulting in a
non-linear scale. The shape of the scale can
be made almost linear by
(i) keeping rate of change of inductance
L, with deflection 0, as constant.
(ii) keeping –1
' d0j as constant.
0
(iii) keeping —1
as constant, where k is k0
the spring constant.
dL (iv) keeping 0 . — as constant.
d0
(g) The difference between the Spectrum
Analyser (SA) and CRO is
(i) CRO and SA both measure time
domain signal.
(ii) CRO and SA both measure frequency
domain signal.
(iii) CRO measures time domain signal
and SA measures frequency domain
signal.
(iv) CRO measures frequency domain
signal and SA measures time domain
signal.
BIEL-029
3 P.T.O.
2. (a) Explain various static and dynamic
characteristics of instruments. 10
(b) A 600 V voltmeter is specified to be
accurate within ± 2.5% at Full Scale
Deflection (FSD). Calculate the limiting
error when the instrument is used to
measure a voltage of 400 V. 4
3. (a) Explain why PMMC instruments are most
widely used. Discuss their advantages and
disadvantages. 7
(b) Describe the working of an analog AC
ammeter and voltmeter.
4. (a) Define the sensitivity and deflection factor
of a Cathode Ray Tube (CRT). What are the
roles of the following in a CRO ?
7
(i) Time Based Generator Circuit
(ii) X-Channel
(iii) Triggered Sweep
(iv) Astigmatism
(b) Differentiate between a Double Beam CRO
and Dual Trace CRO in detail. 7
BIEL-029 4
. (a) Draw the block diagram and working of an
integrating type Digital Voltmeter (DVM). 7
(b) An integrator has 100 kQ and 11./F
capacitor. If the voltage applied to the
integrator input is 1 V, find the voltage
developed at the output after 1 sec. If the
reference voltage applied to the integrator
at time t 1 is 5 V, find the time interval
of t2 .
t 1 --> rise time of reference voltage waveform
at the output of the integrator
t2 —> fall time of reference voltage waveform 7
6. (a) Explain with a neat diagram, the working
of a pulse generator. 7
(b) Draw the block diagram of a 'Digital phase
meter'. Also, explain its working operation. 7
7. Write short notes on any two of the following : 2x7=14
(a) Spectrum Analyzer
(b) Grounding
(c) Q-Meter
BIEL-029
5 1,000