+ All Categories
Home > Documents > BioShield CLP Commercial UV Disinfection System

BioShield CLP Commercial UV Disinfection System

Date post: 26-Nov-2021
Category:
Upload: others
View: 4 times
Download: 0 times
Share this document with a friend
6
PENTAIR.COM BIOSHIELD ® CLP COMMERCIAL UV DISINFECTION SYSTEM UV DISINFECTION SYSTEM Establishing a bio-secure swimming facility begins at the pool design stage. Pentair BioShield Commercial low-pressure UV systems are a proven solution to protect against Giardia, harmful waterborne pathogens and irritating chloramines. STANDARD FEATURES • Significantly reduces chemical odors within enclosed pool area. • Conserve more Free-Chlorine when compared to medium pressure UV systems • Standard sizes available up to 3,400 GPM and NSF 50 Certified to 100 PSI. • UL 508A Listed. • Cost-effective Schedule 80 solvent welded PVC plastic vessels stand up to corrosive Chlorine environments. • High quality American made low-pressure, Amalgam UV lamps offer up to 12,000 hours of continuous operation. • Low temperature lamps conserve energy and negate the need for quartz sleeve wiper systems. • Choice of input/output piping connections. • Suitable for indoor and outdoor pools.
Transcript
Page 1: BioShield CLP Commercial UV Disinfection System

PENTAIR.COM

BIOSHIELD® CLPCOMMERCIAL UV DISINFECTION SYSTEM

UV DISINFECTION SYSTEMEstablishing a bio-secure swimming facility begins at the pool design stage.

Pentair BioShield Commercial low-pressure UV systems are a proven

solution to protect against Giardia, harmful waterborne pathogens and

irritating chloramines.

STANDARD FEATURES• Significantly reduces chemical odors within

enclosed pool area.

• Conserve more Free-Chlorine when compared to medium pressure UV systems

• Standard sizes available up to 3,400 GPM and NSF 50 Certified to 100 PSI.

• UL 508A Listed.

• Cost-effective Schedule 80 solvent welded PVC plastic vessels stand up to corrosive Chlorine environments.

• High quality American made low-pressure, Amalgam UV lamps offer up to 12,000 hours of continuous operation.

• Low temperature lamps conserve energy and negate the need for quartz sleeve wiper systems.

• Choice of input/output piping connections.

• Suitable for indoor and outdoor pools.

Page 2: BioShield CLP Commercial UV Disinfection System

PENTAIR.COM

BIOSHIELD® CLPCOMMERCIAL UV DISINFECTION SYSTEM

BIOSHIELD UV SYSTEM ADDITIONAL FEATURES• Single-end UV lamp and quartz sleeve

access for easy servicing.

• Enhanced, state-of-the-art electronic ballast, sized precisely to the lamp’s power requirement, ensures optimal UV-C output and maximum lamp life.

• Water-tight design protects all electrical hardware from water damage.

• Compact footprint models reduce required operating space.

• 20 ft. lamp cables.

• Touch screen interface with tabulated screens for easy command initiation.

STANDARD FEATURES• Digitally displayed, resettable total operating hour meter.

• Individual Lamp Status and Lamp Life Monitor—alarm triggered upon end-of-useful-lamp-life (12,000 hours).

• Power supply enclosure temperature sensor/alarm—Protects internal components from temperatures exceeding 140˚F.

• UV Vessel water temperature sensor/alarm—Protects vessel from temperatures exceeding 120˚F.

• UV Intensity sensor/alarm—Monitors UV intensity inside the reactor vessel and measures UV-C lamp output percent (1-100%).

• Output Alarm Relay—100mA, normally open “Form A” dry contact for enunciation of above alarm conditions to external controller.

• Thermoplastic NEMA 12 enclosure.

Page 3: BioShield CLP Commercial UV Disinfection System

LOW PRESSURE UV IS THE PROVEN GREEN SOLUTIONTwo UV technologies exist: Low-pressure (LP) and Medium-pressure (MP). Both UV technologies inactivate dangerous pathogens and irritating Chloramines but MP UV systems cost almost 3x more to operate than LP. In the past, Medium-pressure UV systems were believed to be more effective than Low-pressure due to MP’s high UV-C light output and compact package, but over the years LP UV lamp technology has improved to the point where LP lamps are now 5x more powerful than they were initially. Today, LP UV lamp technology continues to evolve and has significantly narrowed the gap of number of lamps required between MP and LP UV systems. The result is that LP UV systems now cost nearly 3x less to operate than MP UV systems.

LP and MP UV lamps operate very differently. MP UV lamps convert 11-15% of their input electricity into UV-C light. LP UV lamps convert 35-40%, making them much more effective and cost-efficient at germicidal disinfection and Chloramine control.

Spectra AbsorptionThe data displayed in the Spectral Absorbance chart below is universal according to the laws of science; it applies to all Low-pressure and Medium-pressure UV systems. The chart also identifies several materials associated with swimming pool water at the specific wavelengths that inactivate them.

E. Coli Giardia

2000

4

8

12

16

Wavelength, nm

Spec

tral

Em

itta

nce,

rel

Low-Pressure Lamp Power Distribution

280250 300 350 400315 450 500 550 600 650 700 750 780

Medium-Pressure Lamp Power DistributionAbsorption DNA (Germicidal Curve)

Free-ChlorineUV Absorption

Spectra 290 nm

Tri-chloramineUV Absorption

Spectra 340 nm

MonochloramineUV Absorption

Spectra 246 nm

Di-chloramineUV Absorption

Spectra 297 nm

UV-C UV-A VISIBLE LIGHTUV-B

264 nm Peak Germicidal Efficiency

250 nm-280 nm250 nm-280 nm

Page 4: BioShield CLP Commercial UV Disinfection System

2000

4

8

12

16

Wavelength, nm

Spec

tral

Em

itta

nce,

rel

Low-Pressure Lamp Power Distribution

280250 300 350 400315 450 500 550 600 650 700 750 780

Medium-Pressure Lamp Power DistributionAbsorption DNA (Germicidal Curve)

Free-ChlorineUV Absorption

Spectra 290 nm

Tri-chloramineUV Absorption

Spectra 340 nm

MonochloramineUV Absorption

Spectra 246 nm

Di-chloramineUV Absorption

Spectra 297 nm

UV-C UV-A VISIBLE LIGHTUV-B

264 nm Peak Germicidal Efficiency

250 nm-280 nm250 nm-280 nm

PENTAIR.COM

MONEY-SAVING FACTSConserve Free-ChlorineMP UV lamps decay Free-Chlorine (see Spectral Absorbance Chart) which increases operational cost. LP UV lamps are proven to conserve Free-Chlorine, saving you money.

Low Heat OutputLP Amalgam lamps operate at 180°F, MP lamps at 1,600°F. The extreme heat generated by MP UV lamps intensifies the problem of quartz sleeve fouling and creates the need for expensive and problematic quartz sleeve wiping systems. This ultimately complicates equipment maintenance. BioShield Amalgam UV lamps operate at a fraction of that heat output and do not require the addition of a quartz sleeve wiping system.

Longest Lamp-LifeLP UV lamp life of 12,000 hours, outlast MP lamps by as much as 3 times. Even with the need for additional lamps compared to MP, the high cost and short life of MP make LP UV up to 3 times less costly to maintain.

For example: a 288,000 gallon pool using a MP UV system, operating at 800 GPM, and delivering a UV dose to 60 mJ/cm², replaces MP UV lamps annually at a cost of $1,120 each ($3,300). Compare that to a LP UV system which replaces 7 lamps annually at a cost of $160 each ($1,120).

Proof Is In The Science Regardless of UV system manufacturer claims, the Spectra Chart below clearly illustrates just how much more efficient LP UV technology is compared to MP at inactivating waterborne pathogens and Chloramines. The chart reveals the spectral output of both LP and MP UV lamps and the specific light-spectra that inactivates pathogen-DNA, Chloramines and Free-Chlorine.

Page 5: BioShield CLP Commercial UV Disinfection System

SIZING YOUR BIOSHIELD® UV SYSTEM1. Establishing flow rate requirements in GPM is critical to selecting the correct UV system for your application.

2. Know Target Dose. Target Dose depends on the intended purpose of the UV reactor. While this can be complicated, the following rules-of-thumb are often used at minimum:

UV Dose Standard Commercial Application

40 mJ/cm² Inactivation of chlorine tolerant pathogens

60 mJ/cm² Additional breakdown of Chloramines for greatly improved air and water quality

3. Standard Commercial Application. Select desired UV dose column below. Identify maximum flow rate that meets system flow rate requirement. Complete this step for model CLP4 or CLP6 and with provided vessel and power enclosure dimensions, choose the best model suited for the mechanical space. *Note: Small port size may restrict actual maximum flow rate.

Model¹Lamps/Watts

Max Flow Rate (GPM) 40 mJ/cm²

Max Flow Rate (GPM) 60 mJ/cm²

Port Size²

Max Flow

Amps Max Load

UV Vessel Dimensions²

(A x B x C)

Power Enclosure Dimensions

(H x W x D)Max PSI

ONLY AVAILABLE IN 120VAC

CLP41A6-XN 1/130 62 42 2" *64 2.1/1.0 56" x 6"x 47" 24.6" x 20.2" x 10.6" 100

CLP42A6-XN 2/130 105 70 3" *144 3.9/2.0 56" x 6" x 47" 24.6" x 20.2" x 10.6" 100

CLP43A6-XN 3/130 152 101 3" *144 5.8/2.9 56" x 6" x 47" 24.6" x 20.2" x 10.6" 1004" *251

CLP43A8-XN 3/130 225 150 4" *251 5.8/2.9 62" x 8" x 51" 24.6" x 20.2" x 10.6" 100

CLP44A8-XN 4/130 295 196 4" *251 7.5/3.7 62" x 8" x 51" 24.6" x 20.2" x 10.6" 1006" *569

CLP45A8-XN 5/130 350 233 4" *251 9.4/4.7 62" x 8" x 51" 30.5" x 24.9" x 12.6" 1006" *569

CLP46A10-XN 6/130 500 334 6" *569 11.2/5.6 64" x 10" x 51" 30.5" x 24.9" x 12.6" 75

CLP47A10-XN 7/130 585 390 6" *569 13.3/6.5 64" x 10" x 51" 30.5" x 24.9" x 12.6" 758" *996

CLP47A12-XN 7/130 700 467 6" *569 13.3/6.5 69" x 12" x 51" 30.5" x 24.9" x 12.6" 508" *996

CLP48A12-XN 8/130 790 525 6" *569 15.0/7.5 69" x 12" x 51" 30.5" x 24.9" x 12.6" 508" *996

ONLY AVAILABLE IN 240VAC

CLP61A6-XN 1/320 185 123 3" *144 1.6 85" x 6" x 76" 24.6 " x 20.2" x 10.6" 1004" *251

CLP62A6-XN 2/320 325 216 4" *251 3 85" x 6" x 76" 24.6 " x 20.2" x 10.6" 1006" *569

CLP63A6-XN 3/320 465 310 4" *251 4.5 85" x 6" x 76" 24.6 " x 20.2" x 10.6" 1006" *569

CLP63A8-XN 3/320 660 438 6" *569 4.5 85" x 6" x 76" 24.6 " x 20.2" x 10.6" 100

CLP64A8-XN 4/320 850 566 6" *569 6 85" x 6" x 76" 24.6 " x 20.2" x 10.6" 100

CLP65A8-XN 5/320 1020 678 6" *569 7.5 85" x 6" x 76" 30.5" x 24.1" x 12.6" 100

CLP66A10-XN 6/320 1470 979 8" *996 9 88" x10"x 76" 30.5" x 24.1" x 12.6" 75

CLP67A10-XN 7/320 1730 1158 8" *996 11 88" x10"x 76" 30.5" x 24.1" x 12.6" 75

CLP67A12-XN 7/320 2080 1385 8" *996 11 90" x 12" x 76" 30.5" x 24.1" x 12.6" 5010" *1567

CLP68A12-XN 8/320 2350 1566 10" *1567 13 90" x 12" x 76" 30.5" x 24.1" x 12.6" 50

CLP69A14-XN 9/320 2870 1912 12" *2218 14 92" x 14" x 76" 40.4" x 32.5" x 12.6" 50

CLP610A16-XN 10/320 3400 2267 14" *2650 16 94" x 16" x 76" 40.4" x 32.5" x 12.6" 50

¹ When ordering: Replace 'X' in part number with requested flange size; e.g. CLP41A6-2N for two-inch flange.

² Vessel dimension 'C' represents clearance requirements for glassware maintenance.

QUARTZ SLEEVE/UVLAMP ACCESS PORTS

WATER OUTLET PORTTEMP SENSOR PORT

WATERINLETPORT

W

H

UV SENSOR PORT

WATER DRAIN PORTREMOVABLE HEAD SECTION

CLEARANCE REQUIREDFOR LAMP & QS REMOVAL = C

LAMP FIELD SAFETY COVER

B

A

Page 6: BioShield CLP Commercial UV Disinfection System

400 Regency Forest Dr | Cary, NC 27518 | United States | 800.831.7133 | pentair.com

All indicated Pentair trademarks and logos are property of Pentair Inc. Third party registered and unregistered trademarks and logos are the property of their respective owners.

PCA-102 02/2021 ©Pentair. All Rights Reserved.

THE PROVEN SOLUTIONHealthy swimming is a matter of clean water and air conditions. Whether you swim in a residential or public pool, pool water and air quality can make you sick.

UV has proven to be a solution for dangerous RWI’s (Recreational Water Illnesses) and Chloramines (Chemical Irritants). UV Treatment is as natural as sunlight. More specifically, UV-C light is a natural component of the electromagnetic radiation that the Sun emits. Much of the Sun’s radiation is absorbed by ozone in the Earth’s upper atmosphere, but some UV-C light passes through and inactivates exposed microorganisms, including those found in surface waters.

UV systems operate the same way. Inside a UV system, UV lamps emit UV-C light (wavelength range 240-280 nm). Waterborne pathogens in the water circulating through the UV vessel are exposed to the UV-C light for a determined amount of time and become inactivated.

SOLUTION FOR GERMS THAT CAUSE RWI’SUV is instant germicidal disinfection, Free Chlorine is not. UV disinfection inactivates germs (Giardia and E. Coli.) most commonly associated with RWI’s. UV disinfection provides instant (single-pass) treatment unlike Free-Chlorine and ozone.

UV systems are a “Green” Technology and deliver multiple benefits contributing to healthy swim water.

REDUCED CHLORAMINESIf you have swimmers and pool staff suffering from eye and nasal irritation, it ’s most likely the result of high Chloramine levels (Dichloramine and Trichloramine). Chloramines, by-products of Free-Chlorine disinfection, form when the Free-Chlorine reacts with ammonia (sweat, urine and other waste from swimmers) in the pool water. As Chloramine levels build, they release into the atmosphere. Warm temperatures, unacceptable pH, high bather use and inadequate turn-over (filtering) are the most common causes of high Chloramine levels. The typical solution pool operators use to solve their out-of-control Chloramines problem is “Super-Chlorination”, which is to increase Free-Chlorine from 1.0/I to 5.0 mg/I, but UV systems are a gentler and more effective solution.

UV SYSTEMS ARE PROVEN TO BE VERY EFFECTIVE IN THE TREATMENT OF CHLORAMINESSpecific wavelengths of UV light will break down the bonds of chloramine molecules, effectively destroying them.

Chlorine Disinfection Is Not Instant

AGENTDISINFECTANT TIMES FOR FECAL

CONTAMINANTS IN CHLORINATED WATER*

E. Coli 0157:H7Bacterium

<<1 minute

Hepatitis AVirus

approximately 16 minutes

GiardiaParasite

approximately 45 minutes

*1 mg/L (1ppm) free chlorine at pH 7.5 and 25°C (77°F)*These disinfectant times are only for pools that do not use chlorine stabilizers such as cyanuric acid. Disinfection times would be expected to be longer in the presence of a chlorine stabilizer.

UV Disinfection Is InstantRequired Microorganism UV Dose

UV Dosage in mJ/cm²

0 20 4010 30 50

Bacteria

Protozoa

Ecoli6.6mJ/cm²

Giardiaintestinalis (cysts)34 mJ/cm²

AN ECO SELECT® BRAND PRODUCTThe BioShield® UV system has earned the Eco Select brand distinction from Pentair for its efficiency and environmentally friendly performance.


Recommended