+ All Categories
Home > Documents > Birkett Street - City of Stirling ick & Tle-Clear B u s h e s C/Bond Fence Good C ond it n S e w e r...

Birkett Street - City of Stirling ick & Tle-Clear B u s h e s C/Bond Fence Good C ond it n S e w e r...

Date post: 15-Jun-2018
Category:
Upload: nguyendieu
View: 214 times
Download: 0 times
Share this document with a friend
4
D.P D.P D.P D.P D.P D.P D.P SW 1.2 x 1.5 SW 1.5 x 1.2 NOTE: ALL DOWNPIPES CONNECTED TO SOAKWELLS WITH PVC STORMWATER PIPE BY BUILDER SCALE: DRAWN: DATE: CC APRIL 17 1:200 CHK: MS © COPYRIGHT DATE DRAWN CHK 2,000 1,610 3,590 4,500 17,890 6,099 2,580 10,540 2,729 1,511 2,999 17,890 3,101 609 1,511 2,581 12,039 5,600 5,510 5, 00 0 3, 31 9 60 4,068 17,890 4,169 2,581 12,470 1,068 2,581 12,470 1,068 4,500 17,890 6,099 TBA #5 TBA #6 TBA #1 TBA #2 TBA #3 TBA #4 ALFRESCO PAVED @ -1c PORCH PAVED @ -1c PROPOSED RESIDENCE FFL: 10.05 EXTENT OF UPPER FLOOR ABOVE 90mm PVC PIPE (RETIC) UNDER DRIVEWAY GARAGE GRANO @ -1c EDGE OF GRANO COMB. M'BOX GAS / ELECT. 29c HIGH 1c FACEBRICK WALL 60mm INSIDE BOUNDARY WITH SQUARELINE GUTTER, FIREPROOF FLASHING & TERMITE TREATMENT (REFER DETAIL SHEET) PRELAY BALCONY FW IN PIER ZONE: R30 SITE COVER ALLOWED: 55% ACTUAL SITE COVER: 192.86m 2 / 454m 2 = 42.48% -WIND CLASSIFICATION (N1) AS PER AS 4055 MAINTAIN 3m CLEARANCE TO ALL POWER LINES AT ALL TIMES PROJECT No. SHEET No. 02 of 17 17792 SITE PLAN CLIENT: BUILDER: DATE: CLIENT: No further structural changes These are the plans referred to in the Building Contract CONTRACT PLANS VARIATION ENGINEERS 02/05/17 CC CC SUPERVISOR NOTE: * ALL STEEL BEAMS TO BE DELIVERED TO GARAGE AREA. NO STEEL BEAMS TO BE LOCATED WITHIN 6m OVERHEAD POWER LINE DANGER ZONE. * CONCRETE PUMP TO BE LINE PUMP ONLY (NO OVERHEAD PUMP) WHERE NECESSARY. SUPERVISOR BRICKLAYER NOTE: T-BAR LINTELS TO BE INSTALLED AT SAME TIME AS STEEL BEAMS SUPERVISOR NOTE: WHERE POSSIBLE, CONCRETE TRUCK & CRANE ACCESS TO BE FROM ADJOINING PROPERTY TO MAINTAIN 6m CLEARANCE FROM TRANSMISSION VOLTAGE POWER LINES. IF NOT, WESTERN POWER REQUIRES 3 WEEKS NOTICE TO PROVIDE A SAFE WORK ENVIRONMENT AROUND POWER LINES. CLIENT NOTE: REMOVAL AND RE-INSTATEMENT OF FENCING BY OWNER TO BUILDERS SCHEDULE. OWNER TO LIASE WITH NEIGHBOUR(S) ACCORDINGLY. CROSSOVER BY OWNER TO COUNCIL & DEVELOPER SPECIFICATIONS (REFER TO ADDENDA) 1 2 3 4 5 6 7 8 9 SITEPLAN LEGEND - 1 - SAND DELIVERY - 2 - SITE SHED - 3 - SITE TOILET - 4 - TIMBER DELIVERY - 5 - STEEL DELIVERY (TO STAY OUTSIDE OF ANY WESTERN POWER EASEMENT) - 6 - CRANE - 7 - BRICK / RUBBISH PILE - 8 - WALL FRAME - 9 - ROOF TRUSSES NBN/ TELSTRA PIT & PIPE DESIGN REQUIREMENTS PLANS TO BE READ IN CONJUNCTION WITH CONSULTANTS ISSUED FOR CONSTRUCTION DRAWINGS ELECTRICIAN NOTE: ELECTRICIAN TO ENSURE NBN/TELSTRA INTERNAL CONDUIT PATHWAYS ARE INSTALLED AND MANDREL TESTED IN ACCORDANCE WITH APPROVED PLANS AT THE SAME TIME AS POWER RUN IN 1M WIDE 0.001 m SSL1 MISCLOSE . Birkett Street Bitumen Semi-Mount Nil Changes to the City Of Stirling Street & Reserve Trees Policy require minimum setbacks to all crossovers dependant on the Diameter At Breast Height (DBH) of any verge trees. Cottage & Engineering Surveys recommends contacting City Of Stirling to verify any verge tree details with their tree audit database before any design work is undertaken. NOTE: OLD AREA TELSTRA/COMMS. PIT NOT LOCATED ADJACENT TO LOT AT TIME OF SURVEY. VERIFY AVAILABILITY WITH TELSTRA. NOTE: WARNING: Check developer/strata company regarding possible future/existing internal service run ins, positions & details. Check for possible private sewer lines & position & details of connection to strata lot. Beware possible building restrictions on strata lot by management statement or by-laws. If strata boundaries not defined on plan only parent lot may be re-pegged and line pegs placed. Scale 1:200 0 2 4 6 8 W S E N SSL1 413151 14 Mar 17 M. Bateman Builder : Ben Trager Homes CLIENT : Baginski SURVEY STRATA LOT 1 #168A Birkett Street, Dianella Survey Strata Plan73125 Original Lot 54 on Diag. 19969 1:200 c J/N: DATE: DRAWN: SCALE: Licensed Surveyors 87-89 Guthrie Street, Osborne Park, Western Australia Telephone: (08) 9446 7361 Facsimile: (08) 9445 2998 Email : [email protected] Website: www.cottage.com.au Lot boundaries drawn on survey are based on landgate plan only. Survey does not include title search and as such may not show easements or other interests not shown on plan. Title should be checked to verify all lot details and for any easements or other interests which may affect building on the property. Survey does not include verification of cadastral boundaries. All features and levels shown are based on orientation to existing pegs and fences only which may not be on correct cadastral alignment. Any designs based or dependent on the location of existing features should have those features' location verified in relation to the true boundary. Survey shows visible features only and will not show locations of underground pipes or conduits for internal or mains services. Verification of the location of all internal and mains services should be confirmed prior to finalisation of any design work. Cottage & Engineering surveys accept no responsibility for any physical on site changes to the parcel or portion of the parcel of land shown on this survey including any adjoining neighbours levels and features that have occurred after the date on this survey. All Sewer details plotted from information supplied by Water Corporation. DISCLAIMER: DISCLAIMER: DISCLAIMER: DISCLAIMER: SEC Dome Power Pole Phone Pits LEGEND T C TP10.00 TW TR TF [ [ [ [ 10.00 10.00 10.00 ] ] ] ] Top Pillar/Post Top Wall Top Retaining Top Fence W Water Conn. 48.88 90°0'25" 5.5 2.12 225°0'0" 225°0'0" 90°0'0" 20.4 89°59'35" 20.12 90°0'25" SOIL DESCRIPTION FILL- Sand trace artificial material-brown Sand - pale grey / Fill Sand, Topsoil Light Grass Cover 0.004 m SSL2 MISCLOSE 28.49 13.12 4.24 23.99 135°0'13" 135°0'12" 14.62 89°59'35" (20.12) (48.89) 9.96 9.97 10.01 9.95 9.90 10.01 9.89 9.87 9.87 9.88 10.00 9.98 9.92 9.76 9.91 9.84 9.89 9.90 9.86 11.78 9.87 9.83 9.98 9.98 9.96 11.86 10.98 11.01 10.13 10.07 Ref Nail At Base Of Kerb Assumed Datum 10.00 m Concrete Crossover Semi-Mount W Conn. Large Grass Tree 9.96 9.98 9.98 9.83 Sewer I.O. TF [ ] TF [ ] TF [ ] TF [ ] Timber & Galv Carport Closest Wire To Boundary NOTE/BEWARE:ADVISE TRADES O/Head power lines Brick & Tile -Clear Bushes C/Bond Fence Good Condition Sewer M/H Approx. 61m (10.52) >>> >>> PEG FND NUMB PEG FND NUMB PEG FND NUMB PEG FND NUMB PEG FND NUMB PEG GONE (Not Located In Field. Plotted From Water Corp. Sheet Only) Sewer M/H Unable to Calculate Sewer Junction Depth Due to Lack of Information on Water Corporation E-Plan. Verify Junction Invert, Depth & Details With Water Corporation. BUILDER and PLUMBER check GRADE NOTE: Sewer Junction In: 1.7 Inv: 8.4 NOTE: UP NOTE: Approx. Sewer Clearance Line (This line is NOT an easement) Setbacks MUST be confirmed by Water Corp. before any design work is undertaken. This line is NOT definitive. (Meas Abt. 13.12) 10.0 10.0 SSL2 Tree Ø 0.4m Ht 5.0m VACANT 3x CONDUIT LAID UNDER SLAB BOUNDARY WALL CLIENT NOTE: OWNER TO REMOVE TREE PRIOR TO BUILDER COMMENCING ON SITE INDICATES SET-OUT PEGS BY LICENCED SURVEYOR INDICATES PARA-NAIL SETOUT BY LICENCED SURVEYOR W PROPOSED WATER METER BY OWNER PRIOR TO CONSTRUCTION OWNER TO AMEND KERB TO BE MOUNTABLE OR AS OTHERWISE SPECIFIED BY SHIRE EHB NOTE: PROVIDE H2 TREATMENT TO ROOF TIMBERS FOR EUROPEAN HOUSE BORER 1200x1000 CONC. HARDSTAND FOR A/C UNIT STORE A GULLY & GRATE CONNECTED TO SOAKWELLS SUPERVISOR / TRADES NOTE: 1M CLEARANCE TO POWER LINES AT ALL TIMES NOTE: APPROX INVERT LEVEL 8.89 EXTENT OF OVERSHADOWING (18.36m 2 ) CONCRETOR NOTE: DIG FOOTINGS LAST & POUR FIRST. BOTTOM OF FOOTINGS TO MATCH NEIGHBOUR FOOTINGS TERMITE TREATMENT TERMITE TREATMENT WILL BE IN ACCORDANCE WITH THE NATIONAL CONSTRUCTION CODE 2016 PART 3.1.3, PART 2.1.1 AND PART 1.0.7 USING TERMICO TERMITE MANAGEMENT SYSTEM PAVED DRIVEWAY PAVED PATH D.P RECESSED INSTANT GAS HWU Grano / Paving Areas GARAGE PAVED DRIVEWAY ALFRESCO PORCH STORE A PAVED PATH AREA 34.68 25.96 18.92 6.42 5.71 3.09 Perimeter 23.56 20.22 18.90 12.80 12.74 8.18
Transcript

D.P

D.P

D.P

D.P

D.P

D.P

D.P

SW1.2 x 1.5

SW1.5 x 1.2

NOTE: ALL DOWNPIPESCONNECTED TO

SOAKWELLS WITH PVCSTORMWATER PIPE BY

BUILDER

SCALE:DRAWN: DATE:CC APRIL 17

1:200 CHK: MS

© COPYRIGHT

DATE DRAWN CHK

2,000

1,610 3,590

4,500

17,89

06,0

99

2,580 10,5402,729 1,511

2,999

17,89

03,1

01

609

1,511

2,581 12,039

5,600

5,510

5,000 3,319

60

4,068

17,89

04,1

69

2,581 12,470 1,068

2,581 12,470 1,068

4,500

17,89

06,0

99

TBA #5

TBA #6

TBA #1

TBA #2

TBA #3 TBA #4

ALFRESCOPAVED @ -1c

PORCHPAVED @ -1c

PROPOSEDRESIDENCEFFL: 10.05

EXTENT OF UPPER FLOOR ABOVE

90mm PVC PIPE(RETIC) UNDER

DRIVEWAY

GARAGEGRANO @ -1c

EDGE OF GRANO COMB. M'BOXGAS / ELECT.

29c HIGH 1c FACEBRICK WALL 60mm INSIDEBOUNDARY WITH SQUARELINE GUTTER,

FIREPROOF FLASHING & TERMITE TREATMENT (REFER DETAIL SHEET)

PRELAY BALCONYFW IN PIER

ZONE: R30 SITE COVERALLOWED: 55%

ACTUAL SITE COVER:192.86m2 / 454m2 = 42.48%

-WIND CLASSIFICATION (N1)AS PER AS 4055

MAINTAIN 3m CLEARANCE TOALL POWER LINES AT ALL TIMES

PROJECT No. SHEET No. 02 of 1717792

SITE PLAN

CLIENT:

BUILDER:

DATE:

CLIENT:

No further structural changes

These are the plans referred to in the Building Contract

CONT

RACT

PLA

NS

VARIATIONENGINEERS 02/05/17 CC CC

SUPERVISOR NOTE:* ALL STEEL BEAMS TO BE DELIVERED TO

GARAGE AREA. NO STEEL BEAMS TO BE LOCATED WITHIN 6m

OVERHEAD POWER LINE DANGER ZONE.

* CONCRETE PUMP TO BE LINE PUMP ONLY (NO OVERHEAD PUMP) WHERE NECESSARY.

SUPERVISOR BRICKLAYER NOTE:T-BAR LINTELS TO BE INSTALLED AT SAME

TIME AS STEEL BEAMS

SUPERVISOR NOTE:WHERE POSSIBLE, CONCRETE TRUCK &CRANE ACCESS TO BE FROM ADJOININGPROPERTY TO MAINTAIN 6m CLEARANCEFROM TRANSMISSION VOLTAGE POWER

LINES.IF NOT, WESTERN POWER REQUIRES 3 WEEKS

NOTICE TO PROVIDE A SAFE WORKENVIRONMENT AROUND POWER LINES.

CLIENT NOTE:REMOVAL AND RE-INSTATEMENT OF FENCINGBY OWNER TO BUILDERS SCHEDULE. OWNERTO LIASE WITH NEIGHBOUR(S) ACCORDINGLY.

CROSSOVER BY OWNER TOCOUNCIL & DEVELOPER

SPECIFICATIONS(REFER TO ADDENDA)

1

23

4 5

6

7

8 9

SITEPLAN LEGEND - 1 - SAND DELIVERY - 2 - SITE SHED - 3 - SITE TOILET - 4 - TIMBER DELIVERY - 5 - STEEL DELIVERY (TO STAY OUTSIDE OF ANY WESTERN POWER EASEMENT) - 6 - CRANE - 7 - BRICK / RUBBISH PILE - 8 - WALL FRAME - 9 - ROOF TRUSSES

NBN/ TELSTRA PIT & PIPE DESIGNREQUIREMENTS

PLANS TO BE READ IN CONJUNCTION WITHCONSULTANTS ISSUED FOR CONSTRUCTION

DRAWINGS

ELECTRICIAN NOTE:ELECTRICIAN TO ENSURE NBN/TELSTRA

INTERNAL CONDUIT PATHWAYS ARE INSTALLEDAND MANDREL TESTED IN ACCORDANCE WITH

APPROVED PLANS AT THE SAME TIME ASPOWER RUN IN

1M WIDE

0.001 mSSL1 MISCLOSE

.

Birkett StreetBitumen

Semi-Mount Nil

Changes to the City Of Stirling Street & ReserveTrees Policy require minimum setbacks to allcrossovers dependant on the Diameter At BreastHeight (DBH) of any verge trees. Cottage &Engineering Surveys recommends contactingCity Of Stirling to verify any verge tree detailswith their tree audit database before any designwork is undertaken.

NOTE:

OLDAREA

TELSTRA/COMMS. PIT NOT LOCATEDADJACENT TO LOT AT TIME OF SURVEY.VERIFY AVAILABILITY WITH TELSTRA.

NOTE:

WARNING:Check developer/strata company regarding possiblefuture/existing internal service run ins, positions &details. Check for possible private sewer lines &position & details of connection to strata lot. Bewarepossible building restrictions on strata lot bymanagement statement or by-laws. If strataboundaries not defined on plan only parent lot maybe re-pegged and line pegs placed.

Scale 1:200

0 2 4 6 8

W S

EN

SSL1

413151 14 Mar 17 M. Bateman

Builder : Ben Trager HomesCLIENT : BaginskiSURVEY STRATA LOT 1 #168A Birkett Street,Dianella

Survey Strata Plan73125 Original Lot 54 on Diag. 199691:200cJ/N: DATE: DRAWN:SCALE:

Licensed Surveyors

87-89 Guthrie Street, Osborne Park, Western AustraliaTelephone: (08) 9446 7361 Facsimile: (08) 9445 2998

Email : [email protected] Website: www.cottage.com.au

Lot boundaries drawn on survey arebased on landgate plan only. Survey does notinclude title search and as such may not showeasements or other interests not shown on plan.Title should be checked to verify all lot detailsand for any easements or other interests whichmay affect building on the property.

Survey does not include verification of cadastralboundaries. All features and levels shown arebased on orientation to existing pegs and fencesonly which may not be on correct cadastral alignment.Any designs based or dependent on the location ofexisting features should have those features'location verified in relation to the true boundary.

Survey shows visible features only and will notshow locations of underground pipes or conduitsfor internal or mains services. Verification ofthe location of all internal and mains servicesshould be confirmed prior to finalisation of anydesign work.

Cottage & Engineering surveys accept noresponsibility for any physical on site changes tothe parcel or portion of the parcel of land shownon this survey including any adjoining neighbourslevels and features that have occurred after thedate on this survey. All Sewer details plottedfrom information supplied by Water Corporation.

DISCLAIMER:

DISCLAIMER:

DISCLAIMER:

DISCLAIMER:

SEC DomePower PolePhone Pits

LEG

EN

D

T C

TP10.00TWTRTF

[[[[

10.0010.0010.00

]]]]

Top Pillar/PostTop WallTop RetainingTop Fence

W Water Conn.

48.8

8

90°0'25"5.52.1

2

225°0'0"

225°

0'0"

90°0

'0"

20.4

89°59'35"

20.12

90°0

'25"

SOIL DESCRIPTIONFILL- Sand trace artificial material-brownSand - pale grey / Fill Sand, TopsoilLight Grass Cover

0.004 mSSL2 MISCLOSE

28.4

9

13.124.24

23.9

9

135°0'13"135°0'12"

14.6289°5

9'35"

(20.12)

(48.

89)

9.96

9.97

10.0

1

9.95 9.90

10.01

9.89

9.879.

879.8

810.0

0

9.98

9.92

9.76

9.919.

84

9.89

9.909.

8611.78

9.87

9.8

39

.98

9.9

89

.96

11.86

10.98

11.0110.13

10.07

Ref Nail At Base Of KerbAssumed Datum 10.00 m

ConcreteCrossover

Semi-Mount

W

Con

n.

LargeGrassTree

9.9

69

.98

9.9

89

.83

Sewer I.O.

TF[ ]

TF[ ]

TF[ ]

TF[ ]

Timber &Galv Carport

Closest Wire To Boundary

NOTE/BEWARE:ADVISE TRADESO/Head power lines

Brick & Tile-Clear

Bus

hes

C/BondFence Good

Condition

Sewer M/H

Approx. 61m

(10.52)>>> >>>

PEG FNDNUMB

PEG FNDNUMB

PEG FNDNUMB

PEG FNDNUMB

PEG FNDNUMB

PEGGONE

(Not Located In Field. PlottedFrom Water Corp. Sheet Only)

Sewer M/H

Unable to CalculateSewer Junction Depth Due to Lack ofInformation on Water CorporationE-Plan. Verify Junction Invert, Depth& Details With Water Corporation.

BUILDER and PLUMBER check GRADE

NOTE:

Sewer JunctionIn: 1.7Inv: 8.4NOTE: UP

NOTE:Approx. Sewer Clearance Line(This line is NOT an easement)Setbacks MUST be confirmedby Water Corp. before anydesign work is undertaken.This line is NOT definitive.

(Meas Abt. 13.12)

10.0

10.0

SSL2

TreeØ 0.4mHt 5.0m

VACANT

3x CONDUIT LAIDUNDER SLAB

BOUN

DARY

WAL

L

CLIENT NOTE:OWNER TO REMOVE TREE

PRIOR TO BUILDERCOMMENCING ON SITE

INDICATES SET-OUTPEGS BY LICENCED

SURVEYORINDICATES PARA-NAILSETOUT BY LICENCED

SURVEYOR

W

PROPOSED WATERMETER BY OWNER

PRIOR TO CONSTRUCTION

OWNER TO AMENDKERB TO BE MOUNTABLE

OR AS OTHERWISESPECIFIED BY SHIRE

EHB NOTE:PROVIDE H2 TREATMENT TO ROOF

TIMBERS FOR EUROPEAN HOUSE BORER

1200x1000 CONC.HARDSTANDFOR A/C UNIT

STOR

E A

GULLY & GRATECONNECTED

TO SOAKWELLS

SUPERVISOR / TRADES NOTE:1M CLEARANCE TO POWER

LINES AT ALL TIMES

NOTE: APPROX INVERTLEVEL 8.89

EXTENT OFOVERSHADOWING

(18.36m2)

CONCRETOR NOTE:DIG FOOTINGS LAST

& POUR FIRST.BOTTOM OF FOOTINGSTO MATCH NEIGHBOUR

FOOTINGS

TERMITE TREATMENTTERMITE TREATMENT WILL BE IN ACCORDANCEWITH THE NATIONAL CONSTRUCTION CODE 2016

PART 3.1.3, PART 2.1.1 AND PART 1.0.7 USINGTERMICO TERMITE MANAGEMENT SYSTEM

PAVED DRIVEWAY PAVED PATH

D.P

RECESSED INSTANTGAS HWU

Grano / Paving Areas

GARAGEPAVED DRIVEWAYALFRESCOPORCHSTORE APAVED PATH

AREA34.6825.9618.926.425.713.09

Perimeter23.5620.2218.9012.8012.748.18

©CO

PYRI

GHT

CLIE

NT:

ADDR

ESS:

SCAL

E:DR

AWN:

DATE

:CC

APRI

L 17

1:100

DATE

DRAW

N C

HK

CHK:

MS

PROJ

ECT

No.

SHEE

T No

.

05 o

f 17

/Volu

mes/c

ommo

n/Job

s/Clie

nts H

omes

/1700

0 Job

s/177

92 B

agins

ki/Dr

afting

/1779

2.pln

CLIE

NT:

BUILD

ER:

DATE

:

CLIE

NT:

No fu

rther

stru

ctura

l cha

nges

BAGI

NSKI

1779

2

STRA

TA LO

T 1 (

#168

A) B

IRKE

TT S

TREE

TDI

ANEL

LACI

TY O

F ST

IRLIN

G

SONA

TA

ELEV

ATIO

NS

Thes

e are

the p

lans r

eferre

d to i

n the

Buil

ding C

ontra

ct

CONTRACT PLANS

VARI

ATIO

NEN

GINE

ERS

02/05

/17CC

CC

BENC

HMAR

K SP

ECIF

ICAT

ION

.

LEV

EL

7, 1

WA

LTE

RS

DR

IVE

O

SB

OR

NE

PA

RK

6

017

P: (

08) 9

242

0900

F: (0

8) 9

242

0909

AB

N: 5

4 15

5 21

2 57

0 B

LD R

EG

: 138

76

GENERAL NOTES:GROUND FLOOR:RENDERED BRICKWORK TO FRONT ELEVATION - AS INDICATED ONPLAN1c FACE BRICKWORK TO REMAINDER OF RESIDENCE

31c CEILINGS THROUGHOUT U.N.O24º 43' PITCH COLORBOND ROOF WITH 480w BOXED & LINED EAVES

UPPER FLOOR:100mm EPS CLADDING FIXED TO FRAMED WALL AS PERMANUFACTURERS REQ'MENTS

31c CEILINGS THROUGHOUT U.N.O24º 43' PITCH COLORBOND ROOF WITH 480w BOXED & LINED EAVES

50c

28c

64c

29c 33c

35c

10c

GF 0 ( 0c)

2,657

GF Ceiling 2,657 ( 31c)

429

UF 3,086 ( 36c)

2,657

UF Ceiling 5,743 ( 67c)

500

FLASHING

29c HIGH 1c FACEBRICK WALL 60mm INSIDE BOUNDARYWITH SQUARELINE GUTTER, FIREPROOF FLASHING

& TERMITE TREATMENT (REFER DETAIL SHEETS)

170W CONTRASTING RENDEREDEPS CLAD FRAMED

WALL UP TO 50c TO BCA 3.9.2

1c FACE BWK RECESSED INSTANTGAS HWU

obs100mm EPS CLADDING FIXEDTO FRAMED WALL AS PER

MANUFACTURERS REQUIREMENTS

obs

T-BAR @ 27c WITHBWK OVER SETBACK

120mm FROM PIER

EXPOSED TIMBERBEAM @ 63c

MIN

2c HIGH CONTRASTING RENDEREDMOULDING PROTRUDING 20mm

470x590 CONTRASTINGRENDERED PIER UP TO 34c

470 x 590 CONTRASTINGEPS CLAD FRAMED PIER UP

TO 50c WITH 2x 120x120TIMBER POSTS ABOVE

PRIVACY SCREEN TOSUIT R-CODE

REQUIREMENTS

RENDERED BWKN.G.L

N.G.L

28c 28c

64c

29c

-1c

1c FACE BWK

120 x 120TIMBER POST

EXPOSED TIMBER BEAM @ 27c

100mm EPS CLADDING FIXEDTO FRAMED WALL AS PER

MANUFACTURERS REQUIREMENTSFLASHING

450W x 600H WALLPENETRATION

N.G.L N.G.L

50c

28c

64c

7c

GF 0 ( 0c)

2,657

GF Ceiling 2,657 ( 31c)

429

UF 3,086 ( 36c)

2,657

UF Ceiling 5,743 ( 67c)

350

1,000

FLASHING

COMB. GAS/ELECMETERBOX

120 x 120TIMBER POST

T-BAR @ 27c WITHBWK OVER SETBACK

120mm FROM PIER

1c FACE BWK

EXPOSED TIMBER BEAM @ 27c

EXTENT OFRENDERED BWK

100mm EPS CLADDING FIXEDTO FRAMED WALL AS PER

MANUFACTURERS REQUIREMENTSEXPOSED TIMBERBEAM @ 63c

obs

obs

2c HIGH CONTRASTING RENDEREDMOULDING PROTRUDING 20mm

470x590 CONTRASTINGRENDERED PIER UP TO 34c

470 x 590 CONTRASTINGEPS CLAD FRAMED PIER UP

TO 50c WITH 2x 120x120TIMBER POSTS ABOVE

A/C UNITMIN

RENDEREDBWK

170W CONTRASTING RENDEREDEPS CLAD FRAMED

WALL UP TO 50c TO BCA 3.9.2

N.G.L

28c 29c

51c

25c

0c

28c

50c

64c

58c

28c

10c

3c

64c

33c

35c

GF 0 ( 0c)

2,657

GF Ceiling 2,657 ( 31c)

429

UF 3,086 ( 36c)

2,657

UF Ceiling 5,743 ( 67c)

RENDERED BWK

FLASHING

COLORBOND ROOF@ 24°43' PITCH INSTALLED

TO MANUFACTURERSSPECIFICATIONS

REMOTE SECTIONALDOOR AS SELECTED

EXTENT OFRENDERED BWK

SELECTEDBALUSTRADETO BCA 3.9.2

T-BAR @ 25cWITH BWK OVER

100mm EPS CLADDING FIXEDTO FRAMED WALL AS PER

MANUFACTURERS REQUIREMENTS

COLORBOND ROOF@ 24°43' PITCH INSTALLED

TO MANUFACTURERSSPECIFICATIONS

GRANO @ -1c

T-BAR @ 28c WITHBWK OVER SETBACK

120mm FROM PIER

470 x 590 CONTRASTINGEPS CLAD FRAMED PIER UP

TO 50c WITH 2x 120x120TIMBER POSTS ABOVE

EXPOSED TIMBERBEAM @ 63c

2c HIGH CONTRASTING RENDEREDMOULDING PROTRUDING 20mm

470x590 CONTRASTINGRENDERED PIER UP TO 34c

470 x 590 CONTRASTINGEPS CLAD FRAMED PIER UP

TO 50c WITH 2x 120x120TIMBER POSTS ABOVE

N.G.L

EHB NOTE:PROVIDE H2 TREATMENT TO ROOF

TIMBERS FOR EUROPEAN HOUSE BORER

Elevation 2

Elevation 3

Elevation 4

Elevation 1


Recommended