B&R Enclosures HAZARDOUS AREAS CATALOGUE
Transcript
Page 1: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

B&R Enclosures

HAZARDOUS AREASCATALOGUE

Page 2: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.
Page 3: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

Table of Contents

INTRODUCTIONB&R History ---------------------------------------------------------------------------------------2

Capabilities ----------------------------------------------------------------------------------------4

BReakthrough Solutions ----------------------------------------------------------------------6

BRight Ideas ---------------------------------------------------------------------------------------8

PRODUCT SELECTION GUIDELighting ------------------------------------------------------------------------------------------- 10

Enclosures --------------------------------------------------------------------------------------- 12

Plugs & Sockets -------------------------------------------------------------------------------- 12

Weatherproof Lighting & Enclosures --------------------------------------------------- 12

TECHNICAL INFORMATION --------------------------------------------------------------- 13

EX D ENCLOSURESAluminium Ex d Enclosures --------------------------------------------------------------- 18

ENCLOSURESTerminal Boxes ---------------------------------------------------------------------------22 – 28

Control Boxes -----------------------------------------------------------------------------30 – 36

Non-Metallic Enclosures --------------------------------------------------------------38 – 43

LIGHTINGLED Lighting ------------------------------------------------------------------------------46 – 56

Well Glass Lighting ---------------------------------------------------------------------58 – 60

Floodlighting ------------------------------------------------------------------------------62 – 68

Caution Lighting -------------------------------------------------------------------------70 – 73

Fluorescent Lighting -------------------------------------------------------------------74 – 83

Fluorescent & LED Lighting ----------------------------------------------------------84 – 89

PLUG & SOCKET OUTLETSPlug & Socket Outlets ------------------------------------------------------------------92 – 93

WEATHERPROOFFloodlighting ------------------------------------------------------------------------------------ 96

Non-Metallic Control Boxes-------------------------------------------------------- 98 – 100

DisclaimerThis catalogue has been prepared specifically for customers of the publisher and as a general reference only. B&R Enclosures Pty Ltd engages in a policy of continuous development and improvement of its products and reserves the right to alter, add and/or delete specifications of any products or equipment without notice and without incurring liability. The publisher and any party associated with the production of this catalogue do not accept any responsibility or liability whatsoever (to the extent permitted by law) for any inaccuracy, error, misinformation or misleading statements, whether negligently caused or otherwise, contained in this publication. This publication is protected by copyright and may not be reproduced or copied (using any method of reproduction or copying), sold, transmitted, circulated or otherwise forwarded to third parties, in whole or part, without prior written consent of the author. All registered trademarks and product names appearing herein are the property of the respective owners.

Page 4: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.
Page 5: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

edBorn and

Australian

A little bit about B&R Enclosures

Since 1955, B&R has built a reputation for excellence inthe design and manufacture of enclosures. Everything wehave learned in that time, we’ve poured into our productsand relationships.

As a 100% Australian, family-owned business, B&R champions the virtues of quality, service and value. Combined with our unrivalled industry and application knowledge, we are in a unique position to meet the needs of our clients.

The company encompasses four divisions: Industrial, Data ICT, Hazardous Areas and Residential Commercial. Each division has focuses on the unique needs of different market segments.Together, these divisions share the strengths, resources and experience of the founding company to provide attentive customer service, innovative design and superior quality products at a competitive price. Quality is assured with B&R’s certification to ISO 9001:2008.

B&R is also accredited by the Australian Stainless Steel Association as a superior producer of stainless steel products, working to industry best practice.

Our occupational health and safety management system is certified to AS/NZS 4801:2001.

At B&R, we are justifiably proud of our products, and we strive to ensure that you have what you need, when you need them. We have a network of offices and distributors throughout Australia and internationally. Wherever you are, you will be able to buy B&R products nearby.

B&R Enclosures was founded by Dick Bridges in 1955, specialising in sheet metal fabrication, including electrical enclosures for domestic metering applications. With little capital but great enthusiasm for operating his own business and a determination to succeed, Dick commenced operations in his backyard in Adelaide, South Australia.

It was this family determination that has sustained B&R’s growth into manufacturing plants in Brisbane, Adelaide and Sydney, 10 locations nationally and an international network of distributors, allowing them to increase the range, availability, quality and service to their customers.

Under the direction of the founder’s son, Ken and daughter, Chris, B&R Enclosures has grown to be the largest manufacturer of domestic, commercial and industrial enclosures in Australia.

Page 6: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

Length and

With more than 300 employees in different locations, we are ready and able to rise to the biggest challenge.

At B&R, we understand that technology and our people play an important role in making sure our products are of the highest quality. From material through to design and manufacturing, B&R do not compromise on quality. Our final product is not only functional but durable.

Our capabilities include:

• 3D Solidworks modelling

• Automated laser cutter, robotic punching and bending machines

• Robotic foamed in place gasket application machinery

• Automated powdercoating lines with multi-stage pre-treatment process

• Value add services

• Warehousing and distribution

• In-house testing including IP protection rating, salt spray, structural, climate and electrical conformity

eadth

Page 7: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.
Page 8: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.
Page 9: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

At B&R, we not only manufacture and supply a range of enclosure solutions, but we can customise the design to be 100% fit-for-purpose and ready for installation.

B&R Enclosures offer a wide range of services to customise standard product, ensuring that an enclosure is delivered ready for installation. We understand that time is a major consideration on any project and work with our customers to provide products on time and on budget.

We have established two value add divisions located within our manufacturing facilities at Heathwood, Brisbane and Riverwood, Sydney.

brenclosures.com.au

Our services include:

• Door cutouts• Cable entries• Terminals and controls fitted• Viewing windows• Customised wiring• Vent kits / sunshields fitted or punched• Assemble to order / fitting of accessories

What this means for our customers:

• Customised product to suit the project• Shorter lead times• Available for small or large quantities• One point of contact• Standard product straight off the floor

solutionseakthrough

Our people are the best in the business. Experienced professionals with a passion for problem solving and a fl air for innovation.

Page 10: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au

With over 100 years combined industry experience, B&R Enclosures have built a reputation as leaders in the hazardous area market.

Specialising in the supply of electrical equipment for hazardous areas, B&R Ex Systems utilises the manufacturing and distribution network ofB&R Enclosures and a highly experienced team to deliver products of the highest standard.

The company is dedicated to providing superiorquality products, designed to meet the stringent requirements of the internationally recognised IEC Ex Certification Scheme.

B&R Ex Systems accreditation to ISO 9001 for the design, manufacture and distribution of electrical equipment for hazardous areas.

B&R Ex Systems offer a large range of enclosures, lighting, controls and cable glands, as well as IEC Ex certified value add services including custom control fit outs. The dedicated B&R Ex Systems team has over 100 years combined industry experience in the hazardous area market.

The company's philosophy of quality is applied from design through to delivery, so you can be certain your hazardous area projects are safe and reliable.

ideasight

Page 11: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.
Page 12: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

10 Hazardous Areas

LIGHTING

Product Description Protection Method Zones Page No.

LED Exit Light Ex d 1 & 2 46 – 47

LED Lowbay Light Ex d 1 & 2, 21 & 22 48 – 49

LED Linear Light Ex d 1 & 2, 21 & 22 50 – 51

LED Lowbay Light Ex d, Ex t 1 & 2, 21 & 22 52 – 53

LED Lowbay Light Ex d e 1 & 2, 21 & 22 54 – 55

LED Well Glass Ex d, Ex t 1 & 2, 21 & 22 56 – 57

Well Glass Light 400W Ex d 1 & 2 58 – 59

Well Glass Light Ex de 1 & 2 60 – 61

150W – 400W Floodlight Ex de 1 & 2 62 – 63

Well Glass Floodlight Ex nR, Ex t 1 & 2, 21 & 22 64 – 65

150W – 400W Floodlight Ex nR, Ex t 1 & 2, 21 & 22 66

Tank Inspection Vessel Light Ex d 1 & 2 67

300W Halogen Floodlights Ex n R 2 68 – 69

Audio & Visual Caution Light Ex d 1 & 2 70

Visual Caution Light Ex d, Ex t 1 & 2, 21 & 22 71

Local Visual Caution Light Ex de, Ex tb 1 & 2, 21 & 22 72

PRODUCT SELECTION GUIDE

Page 13: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 11

LIGHTING

Product Description Protection Method Zones Page No.

Local Visual Caution Light Ex de, Ex tb 1 & 2, 21 & 22 73

Annular Compact Fluorescent Ex d 1 & 2 74 – 75

Aluminium Fluorescent Ex d 1 & 2 76 – 77

Stainless Steel Fluorescent Ex d emb, Ex d 1 & 2 78 – 79

Non-Metallic FluorescentEmergency & Non-Emergency Ex deq, Ex tD 1 & 2, 21 & 22 80 – 81

Non-Metallic FluorescentEmergency & Non-Emergency

Ex deqmb, Ex tD 1 & 2, 21 & 22 82 – 83

Aluminium Fluorescent & LED Ex d, Ex t 1 & 2, 21 & 22 84 – 85

Non-Metallic Fluorescent & LEDEmergency & Non-Emergency

Ex nA, Ex d nA, Ex d mb,Ex t, Ex mb

2, 21 & 22 86 – 87

Non-Metallic Fluorescent & LED Ex nA, Ex t 2, 21 & 22 88 – 89

Weatherproof Lighting WF1, IP66 – 96 – 97

PRODUCT SELECTION GUIDELIGHTING

Page 14: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

12 Hazardous Areas

ENCLOSURES AND PLUG & SOCKET OUTLETS

Product Description Protection Method Zones Page No.

Ex d Enclosures Ex db, Ex tb, Ex d, Ex t 1 & 2, 21 & 22 18 – 19

Sloping Roof Terminal Box Ex e, Ex nA, Ex de, Ex tD, DIP, Ex t 1 & 2, 21 & 22 22 – 23

Flat Roof Terminal Box Ex e, Ex nA, Ex de, Ex tD, DIP, Ex t 1 & 2, 21 & 22 24 – 25

Flat Roof Terminal Box Ex e, Ex nA, Ex de, Ex tD, DIP, Ex t 1 & 2, 21 & 22 26 – 27

Stainless Steel Terminal Box Ex e, Ex nA, Ex de, Ex tD, DIP, Ex t 1 & 2, 21 & 22 28 –29

Sloping Roof Custom BuiltControl Box

Ex e, Ex nA, Ex de, Ex tD, DIP, Ex t

1 & 2, 21 & 22 30 – 31

Flat Roof Custom BuiltControl Box

Ex e, Ex nA, Ex de, Ex tD, DIP, Ex t 1 & 2, 21 & 22 32 – 33

Flat Roof Custom BuiltControl Box

Ex e, Ex nA, Ex de, Ex tD, DIP, Ex t 1 & 2, 21 & 22 34 – 35

Stainless Steel Control Station Ex e, Ex nA, Ex de, Ex tD, DIP, Ex t 1 & 2, 21 & 22 36 – 37

Non-Metallic Control Station Ex ed, Ex tD 1 & 2, 21 & 22 38 – 39

Non-Metallic Terminal Box Ex e, Ex tD 1 & 2, 21 & 22 40 – 41

Non-Metallic Terminal Box Ex e, Ex tD 1 & 2, 21 & 22 42 – 43

Plug & Socket Outlets Ex de, Ex tD 1 & 2, 21 & 22 92 – 93

Non-Metallic Control Box – – 98 – 99

Weatherproof Control Box – – 100

PRODUCT SELECTION GUIDEENCLOSURES, PLUG & SOCKET OUTLETS

Page 15: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 13

What is a hazardous area?A hazardous area is an area where flammable liquids, vapours, gases or combustible dusts are likely to occur in sufficient quantities to cause fire or explosion. Industries such as metalliferous mining, oil and gas infrastructure, automotive refuelling stations, chemical processing plants, printing industries and cement works often have hazardous applications.

There are three basic conditions that must be satisfied to create a fireor explosion.1. Flammable or combustible material – such as flammable Liquid, vapour or

combustible dust must be present in sufficient quantity and concentration.2. Oxygen3. Ignition source

Hazardous area electrical equipment works by suppressing or separating one or more of these three components to avoid a fire or explosion.

Ignition SourcesThe following ignition sources have the potential to cause an explosion in the right circumstances:

• Electric arcs and spark• Flames• Hot surfaces• Electrostatic sparks• Thermite sparks• Mechanical friction

IEC Standards & CertificationsIEC Ex is an internationally recognised scheme for the certification of hazardous area electrical equipment. The IEC Ex System is designed to facilitate international trade in equipment and services for use in hazardous areas, while maintaining the required level of safety.1

Required InformationThere are 4 important pieces of information required when selecting equipment for hazardous areas.

• Zone Classification• Gas Group• Temperature or T Rating• IP Rating

Zone ClassificationsEquipment that is used in hazardous areas is classified into zones, depending on the potential of an explosion under normal operating conditions. The table below is a guide to zone classification of hazardous areas. B&R Ex Systems does not classify areas for customers, it is the responisbility of the installer or end user to know which zone their area falls within. It is recommended a qualified person is engaged to complete a risk analysis and classify the area in accordance with standard IEC 60079-14.

Gas & vapours Dust Description

Zone 0Ga

Zone 20Da An area in which an explosive atmosphere is continuously present or for long periods or frequently

Zone 1Gb

Zone 21Db An area in which an explosive atmosphere is likely to occur occasionally in normal operation.

Zone 2Gc

Zone 22Dc An area in which an explosive atmosphere is not likely to occur in normal operation.

The hazardous areas are classifi ed in the table above according to IEC 60079-10-1 and IEC 61241-10-2.

Flammable or

combustible material

Oxygen Ignition source

TECHNICAL INFORMATION

• Mechanical sparks produced by grinding• Smouldering deposits• Compression ignition• Electromagnetic radiation• Chemical reactions• Ultrasonics

Page 16: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

14 Hazardous Areas

Gas GroupsElectrical apparatus for use in areas with flammable gases and vapours are divided into groups:Group I – electrical equipment used in underground coal miningGroup II – electrical equipment used in petrochemical industries

Group II is subdivided into 3 groups based on their explosive properties (see table below).

Groups Representative Gas

Group I Methane

Group IIA Propane

Group IIB Ethylene

Group IIC Hydrogen, Acetylene, Carbon Disulphide

Temperature or 'T Rating'Temperature for IgnitionHot surfaces are a potential ignition source in hazardous applications. Hazardous materials will have different minimum temperatures at which ignition becomes a danger. Electrical equipment for hazardous areas is tested and allocated a ‘T Rating’ based on the maximum temperature of the equipment. The ‘T Rating’ must always have a lower maximum temperature than the ignition temperature of the gas group present.

Table 1: provides a summary of the maximum temperatures for the different ratings.

T Rating Maximum Temperature

T1 450ºC

T2 300ºC

T3 200ºC

T4 135ºC

T5 100ºC

T6 85ºC

Table 2: provides some examples of the ignition temperatures and ‘T Ratings’ for gases.

Example Gas Ignition Temperature T Rating

Methane 580ºC T1

Hydrogen 500ºC T1

Kerosene 295ºC T3

Petroleum 400ºC T2

Carbon Disulphide 95ºC T6

Diethyl Ether 160ºC T4

Ethyl Nitrite 95ºC T6

Hydrogen Sulphide 270ºC T3

TECHNICAL INFORMATION

Page 17: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 15

TECHNICAL INFORMATION

DustCombustible DustDust fibres or flyings, which are combustible or ignitable when mixed with air are known as combustible dusts. Dust explosions may be initiated by ignition of a cloud of dust. It is not unusual for an explosion, which starts from the ignition of a dust layer, to cause the dislodging of dust accumulated on various surfaces, which then leads to a dust cloud explosion.

Table 3: Characteristics of some common combustible dusts

Material Minimum ignition energy (mJ)

Ignition temperature

Cloud, ºC Layer, ºC

Aluminium 15 550 740

Coal, Pittsburg (experimental mine coal) 60 610 170

Rice 50 440 220

Sugar 30 370 400

Wheatfl our 30 380 360

NOTE: The data given in this table is derived from AS 2430.2:1986 (superseded by AS/NZS 61241.3 which is superseded by AS/NZS 61241.10)

Protection MethodsTypes of explosion protection for electrical equipment.

Type of Protection Principle Standard Zone

Ex d Flameproof Enclosure Containment – explosion within an enclosure will not be propogated outside the enclosure.

IEC 60079-1 Zone 1 & 2

Ex p Pressurised EnclosuresEnclosure in a protective gas is maintained at a pressure greater than that of the external atmosphere. IEC 60079-2 Zone 1 & 2

Ex q Powder Filling Mounting of potentially incendive components in an enclosure fi lled with quartz or solid glass particles. IEC 60079-5 Zone 1 & 2

Ex o Oil Immersion Equipment or parts are immersed in protective liquid such as oil. The protective liquid acts as an insulating medium. IEC 60079-6 Zone 1 & 2

Ex e Increased Safety Non sparking components are designed to substantially reduce the likelihood of the occurrence of fault conditions which could cause ignition. IEC 60079-7 Zone 1 & 2

Ex i Intrinsic Safety The potential spark energy of a circuit is reduced to below the amount required for ignition.

IEC 60079-11 Zone 0, 1 & 2

Ex n Non–sparkingElectrical apparatus in normal operating conditions and in certain specifi ed abnormal conditions, that is not capable of igniting a surrounding explosive gas atmosphere.

IEC 60079-15 Zone 2

Ex m EncapsulationParts that are capable of igniting an explosive atmosphere by either sparking or heating, are enclosed in a compound so that the explosive atmosphere cannot be ignited under operating or installation conditions.

IEC 60079-18 Zone 0, 1 & 2

Ex t Dust Protection by Enclosure Electrical equipment is protected by the enclosure and surface temperature limitation for use in explosive and dust atmospheres.

IEC 60079-31 Zone 20, 21 & 22

Page 18: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.
Page 19: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

Alu

min

ium

Ex

d E

ncl

osu

res

Page 20: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

18 Hazardous Areas

ALUMINIUM EX D ENCLOSURESZONES 1 & 2, 21 & 22

MATERIALS• Body – Marine grade copper free aluminium body and cover• Fixings – Stainless steel external screws• Mounting plate – Hot dip galvanised steel or aluminium

INCLUSIONS• Customised etched identification label• Earth stud• Hinged lid• Entries, terminals and operators arranged to suit customer requirements

OPTIONS• External epoxy painting with colour on request• Internal anti-condensate painting orange RAL-2004• O-ring gaskets and glass windows on cover• Drain and breather valves

AMBIENT TEMPERATURE-60ºC ~ 130ºC

CONFORMITYIECEx 60079-0:2007IECEx 60079-1:2007IECEx 60079-11:2006IECEx 60079-31:2008

OVERVIEWThe rectangular Ex d enclosure is constructed from aluminium alloy and is suitable for use in hazardous areas with the most demanding conditions. These enclosures are designed to house terminals, electrical equipment and cable terminations. They can be configured for custom built applications such as motor starters, circuit breakers and local control stations. Suitable for application across many industries where reliability and safety are of the highest priority such as offshore, mining and metals, marine, oil & gas, petrochemical and manufacturing industries.

PROTECTIONTerminal BoardsEx db IIB+H2 T6-T3Ex db [ia/ib] IIB+H2 T6-T3Extb IIIC T85ºC – T150ºC

Power UnitsII 2 G Ex d IIB+H2 T6-T3II2 D ex tD A21 T85ºC-150ºC

Control and signallingII2 G Ex d IIB+H2 T6-T3II2 (1) G Ex d [ia] IIB+H2 T6-T3II2 (2) G Ex d [ib] IIB+H2 T6-T3II2 D Ex tD A21 T85ºC-150ºC

IP66

TERMINAL INFORMATION (Reference Guide Only)

Catalogue No.

TerminalsMax. number of operators2.5mm2 6.0mm2 10.0mm2 16.0mm2 35.0mm2 50.0mm2 70.0mm2 240.0mm2

FEJB-11 12 x 1 8 x 1 6 x 1 4 x 1 2 x 1 – – – 6

FEJB-21 30 x 1 20 x 1 14 x 1 12 x 1 8 x 1 6 x 1 2 x 1 1 x 1 12

FEJB-22 44 x 1 30 x 1 20 x 1 18 x 1 12 x 1 10 x 1 4 x 1 2 x 1 12

FEJB-23 35 x 1 22 x 1 16 x 1 14 x 1 11 x 1 9 x 1 7 x 1 2 x 1 16

FEJB-30 52 x 2 32 x 2 24 x 2 20 x 2 14 x 2 12 x 1 8 x 1 4 x 1 30

FEJB-31 52 x 2 32 x 2 24 x 2 20 x 2 14 x 2 12 x 1 8 x 1 4 x 1 30

FEJB-51 80 x 2 46 x 2 36 x 2 30 x 2 22 x 2 18 x 2 16 x 1 6 x 1 54

FEJB-61 92 x 3 58 x 3 46 x 3 38 x 3 28 x 3 26 x 2 22 x 2 12 x 1 56

FEJB-63 92 x 3 58 x 3 46 x 3 38 x 3 28 x 3 26 x 2 22 x 2 12 x 1 56

FEJB-71 110 x 3 70 x 3 56 x 3 46 x 3 34 x 3 28 x 2 24 x 2 12 x 1 48

FEJB-73 110 x 3 70 x 3 56 x 3 46 x 3 34 x 3 28 x 2 24 x 2 12 x 1 48

FEJB-91 140 x 3 90 x 3 70 x 3 60 x 3 44 x 3 36 x 3 32 x 2 14 x 2 54

FEJB-73 140 x 3 90 x 3 70 x 3 60 x 3 44 x 3 36 x 3 32 x 2 14 x 2 54

Page 21: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 19

ALUMINIUM EX D ENCLOSURESZONES 1 & 2, 21 & 22

SELECTION GUIDE

DRILLING LAYOUT

TECHNICAL DRAWINGS

Alu

min

ium

Ex d

Enc

losu

res

Catalogue No.

Dimensions (mm) Fixings (mm) Internal Dimensions (mm)

Height(A)

Width(B)

Depth(D)

Height(E)

Width(F)

Height(H)

Width(G) Depth Weight (kg)

FEJB-11 175 175 125 78 165 115 90 115 3.6

FEJB-21 285 245 169 160 245 217 122 175 10.5

FEJB-22 300 200 220 195 190 235 175 135 12.5

FEJB-23 310 260 197 195 238 247 152 195 15.0

FEJB-30 415 315 168 294 288 340 120 245 18.5

FEJB-31 415 315 250 294 288 340 200 245 20.5

FEJB-51 566 366 257 360 343 495 203 295 36.5

FEJB-61 670 470 360 500 437 595 310 395 57.0

FEJB-63 670 470 235 500 437 595 184 395 47.0

FEJB-71 742 542 425 520 580 645 360 445 110.0

FEJB-73 742 542 308 520 532 645 215 445 90.0

FEJB-91 960 660 460 700 650 830 370 530 202.0

FEJB-93 960 660 305 700 650 830 193 530 145.0

Catalogue No.

Drilling Area (mm)

Width Quantity allowed entries for size Height Quantity allowed entries for size

A B 1 2 3 4 5 6 7 8 C D 1 2 3 4 5 6 7 8

FEJB-11 100 60 3 2 2 1 1 – – – 100 60 3 2 2 1 1 – – –

FEJB-21 200 90 10 7 5 3 2 2 1 – 160 90 8 5 4 3 2 1 1 –

FEJB-22 215 130 15 11 8 6 6 3 2 1 110 130 9 5 5 4 2 1 1 1

FEJB-23 215 105 11 8 6 4 3 3 2 1 165 105 9 6 6 5 2 2 1 1

FEJB-30 320 65 13 7 5 5 4 3 – – 225 65 9 5 4 3 3 2 – –

FEJB-31 320 150 28 18 14 11 8 6 3 2 225 150 20 12 9 8 6 5 2 1

FEJB-51 460 155 44 27 24 20 12 10 6 3 255 155 24 15 12 11 6 6 3 2

FEJB-61 550 220 72 50 36 32 21 21 14 8 350 250 48 30 24 20 12 12 8 6

FEJB-63 550 130 36 29 18 16 14 7 5 4 350 130 24 17 12 10 8 4 3 3

FEJB-71 570 270 90 55 46 39 32 21 15 10 370 270 48 35 35 24 20 15 12 6

FEJB-73 570 160 40 26 22 18 14 12 7 4 370 160 26 18 14 12 8 11 4 2

FEJB-91 745 290 112 84 65 55 40 28 23 14 440 290 70 42 35 35 24 18 13 8

FEJB-93 745 145 48 42 29 22 10 11 9 5 440 145 30 24 21 14 12 7 5 3

THREAD SIZE TABLE

Size UNI 6125 ISO 228/1 ASA B2.1 ISO 965/I

1 GK ½" G ½ ½" NPT M20

2 GK ¾" G ¾" ¾" NPT M25

3 GK 1" G 1" 1" NPT M32

4 GK 1¼" G 1¼" 1¼" NPT M40

5 GK 1½" G 1½" 1½" NPT M50

6 GK 2" G 2" 2" NPT M63

7 GK 2½" G 2½" 2½" NPT M75

8 GK 3" G 3" 3" NPT M85

A

C

▲▲

B

E

D

Dilling layout – front view

Dilling layout – cover

Dilling layout – side view

▲▲

▲▲ ▲▲A

Dilling layout front view

▲ ▲F▲ ▲B

A

▲ ▲▲

▲▲

E

FG

D

H

Page 22: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.
Page 23: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

En

clo

sure

s

Page 24: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

22 Hazardous Areas

CERTIFICATIONIECEx ITA 10.0023x

PROTECTIONEx e IIC T6 GbEx nA IIC T6 Gb, Zone 2 onlyEx de IIC T6 GbEx tD A21/22 T80ºCDIP A21/22 Ta80ºCEx t IIIC T80ºC Db

AMBIENT TEMPERATURE-20ºC ~ +40ºC (to +55ºC)

Australian Made

Australian Owned

IP65/66/67

SLOPING ROOF TERMINAL BOXZONES 1 & 2, 21 & 22

MATERIALS• Body – 316 stainless steel• Body thickness – 1.5mm• Fixings – 316 stainless steel• Surface finish – N4

INCLUSIONS• Steel mounting pan• 7mm stainless steel lock• External mounting flange• Internal and external 6mm or 8mm

earth stud• 3mm stainless steel gland plate• Earth strap kit

OVERVIEWSuitable for use in hazardous areas with the most demanding conditions. The 40º sloping roof minimises the build up of solids on the roof of the enclosure. The 40mm overhang ensures material that slides off the roof is directed away from the top of the door. A complete arrangement of terminals can be fitted ranging from 2.5mm to 300mm. This enclosure also caters for IS terminals.

FEATURES• Customised etched identification label• 40º sloping roof and 40mm overhang• Keyed entry with 7mm stainless steel square lock• Other labelling options available• Threaded entries in gland plate versions• IP66 windows available• Brass gland plate option with up to 3 gland plates available

Bottom ViewWith Internals

▲ ▲L

M

Front View Side ViewWith Internals

▲▲

C

I

▲40

▲16▲

A

D

▲ ▲▲F

A

E

B

Is indicative of lock position when there is only one lock on enclosures

Front ViewWith Internals

G

▲▲ H

▲ ▲K

J

TECHNICAL DRAWINGS

Page 25: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 23

! These enclosures are sold with controls and terminals fi tted. Empty enclosures are not available for sale.Contact your local sales engineer to discuss your specifi c requirements.

SLOPING ROOF TERMINAL BOXZONES 1 & 2, 21 & 22

SELECTION GUIDE

TERMINAL INFORMATION (Reference Guide ONLY)

Terminal Size

Catalogue No.2.5mm2@ 20A

2.5mm2Derated to 10A

4mm2 @ 28A

6mm2@ 36A

10mm2@ 50A

35mm2@ 109A

2.5mm2Instrumentation @ 1A

TBKS030215 13 50 10 9 8 5 25

TBKS030420 12 48 9 8 7 4 105

TBKS040315 11 46 9 8 7 4 110

TBKS040420 12 50 10 8 7 5 165

TBKS040620 13 50 10 9 8 5 275

TBKS040630 16 63 12 11 9 6 275

TBKS060420 16 63 12 11 9 6 275

TBKS060630 20 80 16 14 12 8 455

TBKS080620 19 78 16 14 12 8 455

TBKS080630 25 100 20 18 15 10 625

TBKS100620 23 93 18 16 14 10 790

TBKS120830 48 190 38 35 30 21 1110

Dimensions (mm)

External Mounting Centres OpeningUsable Depth Mounting Pan Gland Opening Gland Plate

Catalogue No. Description A B C D E F G H I J K L M Width Depth No. of Locks

TBKS030215/G0

No gland plate

300 200 150 550 510 100 255 155 105 250 150 – – – – 1

TBKS030420/G0 300 400 200 610 570 300 255 355 155 250 350 – – – – 1

TBKS040315/G0 400 300 150 650 610 200 355 255 105 350 250 – – – – 1

TBKS040420/G0 400 400 200 710 670 300 355 355 155 350 350 – – – – 1

TBKS040620/G0 400 600 200 710 670 500 355 555 155 350 550 – – – – 1

TBKS040630/G0 400 600 300 795 755 500 355 555 255 350 550 – – – – 1

TBKS060420/G0 600 400 200 910 870 300 555 355 155 550 350 – – – – 1

TBKS060630/G0 600 600 300 995 955 500 555 555 255 550 550 – – – – 1

TBKS080620/G0 800 600 200 1110 1070 500 755 555 155 750 550 – – – – 2

TBKS080630/G0 800 600 300 1195 1155 500 755 555 255 750 550 – – – – 2

TBKS100620/G0 1000 600 200 1310 1270 500 955 555 155 950 550 – – – – 2

TBKS120830/G0 1200 800 300 1595 1555 700 1155 755 255 1150 750 – – – – 2

TBKS030215

1 x bottom gland plate

300 200 150 550 510 100 255 155 105 250 150 100 55 140 95 1

TBKS030420 300 400 200 610 570 300 255 355 155 250 350 300 105 340 145 1

TBKS040315 400 300 150 650 610 200 355 255 105 350 250 200 55 240 95 1

TBKS040420 400 400 200 710 670 300 355 355 155 350 350 300 105 340 145 1

TBKS040620 400 600 200 710 670 500 355 555 155 350 550 500 105 540 145 1

TBKS040630 400 600 300 795 755 500 355 555 255 350 550 500 205 540 245 1

TBKS060420 600 400 200 910 870 300 555 355 155 550 350 300 105 340 145 1

TBKS060630 600 600 300 995 955 500 555 555 255 550 550 500 205 540 245 1

TBKS080620 800 600 200 1110 1070 500 755 555 155 750 550 500 105 540 145 2

TBKS080630 800 600 300 1195 1155 500 755 555 255 750 550 500 205 540 245 2

TBKS100620 1000 600 200 1310 1270 500 955 555 155 950 550 500 105 540 145 2

TBKS120830 1200 800 300 1595 1555 700 1155 755 255 1150 750 700 205 740 245 2

TBKS030215/G3

1 bottom gland plate,2 side gland plates

300 200 150 550 510 100 255 155 105 250 150 100 55 140 95 1

TBKS030420/G3 300 400 200 610 570 300 255 355 155 250 350 300 105 340 145 1

TBKS040315/G3 400 300 150 650 610 200 355 255 105 350 250 200 55 240 95 1

TBKS040420/G3 400 400 200 710 670 300 355 355 155 350 350 300 105 340 145 1

TBKS040620/G3 400 600 200 710 670 500 355 555 155 350 550 500 105 540 145 1

TBKS040630/G3 400 600 300 795 755 500 355 555 255 350 550 500 205 540 245 1

TBKS060420/G3 600 400 200 910 870 300 555 355 155 550 350 300 105 340 145 1

TBKS060630/G3 600 600 300 995 955 500 555 555 255 550 550 500 205 540 245 1

TBKS080620/G3 800 600 200 1110 1070 500 755 555 155 750 550 500 105 540 145 2

TBKS080630/G3 800 600 300 1195 1155 500 755 555 255 750 550 500 205 540 245 2

TBKS100620/G3 1000 600 200 1310 1270 500 955 555 155 950 550 500 105 540 145 2

TBKS120830/G3 1200 800 300 1595 1555 700 1155 755 255 1150 750 700 205 740 245 2

Please Note: • Other confi gurations and terminal sizes available, please contact your local B&R sales offi ce for evaluation and wattage calculations.• Quantities for instrumentation has been determined based on 1Amp with consideration to the size of the enclosure.

Term

inal

Box

es

Page 26: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

24 Hazardous Areas

FLAT ROOF TERMINAL BOXZONES 1 & 2, 21 & 22

CERTIFICATIONIECEx ITA 10.0023x

PROTECTIONEx e IIC T6 GbEx nA IIC T6 GcEx de IIC T6 GbEx tD A21/22 T80ºCDIP A21/22 Ta80ºCEx t IIIC T80ºC Db

AMBIENT TEMPERATURE-20ºC ~ +40ºC / 55ºC option

Australian Made

Australian Owned

IP65/66/67

MATERIALS• Body – 316 stainless steel• Body thickness – 1.5mm• Fixings – 316 stainless steel• Surface finish – N4

INCLUSIONS• Steel mounting pan• 3mm stainless steel or 6mm brass

gland plate• 7mm stainless steel lock• Internal and external 6mm or 8mm

earth stud• Earth strap kit• Stainless steel label bracket

OVERVIEWThe flat roof keyed terminal box is made from 316 stainless steel and is suitable for use in hazardous areas with the most demanding conditions. The enclosures are suitable forZones 1 & 2, 21 & 22 applications where flammable liquids, gases & vapours or combustible dusts are frequently present. A complete arrangement of terminals can be fitted ranging from 2.5mm to 300mm.This enclosure also caters for IS terminals.

FEATURES• Customised etched identification label• Keyed entry with 7mm square stainless steel lock• Steel mounting pan• Internal and external 6mm earth stud, 8mm option• Replaceable gaskets• Wall-mounting brackets – M8 fixings• Other label options available• Threaded entries on gland plate versions• IP66 windows availble• Brass gland plate option up to 3 gland plates available

TECHNICAL DRAWINGS

Front View

A

▲ ▲B

Is indicative of lock position when there is one lock on enclosure

Front ViewWith Internals

Side View

E

G

▲ ▲H

Bottom View

▲ ▲C

D

Page 27: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 25

FLAT ROOF TERMINAL BOXZONES 1 & 2, 21 & 22

Dimensions (mm)

External Opening Mounting Pan Gland Opening Gland PlateWall Mount

BracketsNo of LocksCatalogue No. Description A B C D E F G H I J K Width Depth

TBKF030215/G0

No gland plate

300 200 150 108 – 255 155 250 150 – – – – 4 1

TBKF030420/G0 300 400 200 158 – 255 355 250 350 – – – – 4 1

TBKF040315/G0 400 300 150 108 – 355 255 350 250 – – – – 4 1

TBKF040420/G0 400 400 200 158 – 355 355 350 350 – – – – 4 1

TBKF040620/G0 400 600 200 158 – 355 555 350 550 – – – – 4 1

TBKF040630/G0 400 600 300 258 – 355 555 350 550 – – – – 4 1

TBKF060420/G0 600 400 200 158 – 555 355 550 350 – – – – 4 1

TBKF060630/G0 600 600 300 258 – 555 555 550 550 – – – – 4 1

TBKF080620/G0 800 600 200 158 – 755 555 750 550 – – – – 6 2

TBKF080630/G0 800 600 300 258 – 755 555 750 550 – – – – 6 2

TBKF100620/G0 1000 600 200 158 – 955 555 950 550 – – – – 6 2

TBKF120830/G0 1200 800 300 258 – 1155 755 1150 750 – – – – 8 2

TBKF030215

1 x bottom gland plate

300 200 150 108 318 255 155 250 150 100 55 140 95 4 1

TBKF030420 300 400 200 158 318 255 355 250 350 300 105 340 145 4 1

TBKF040315 400 300 150 108 418 355 255 350 250 200 55 240 95 4 1

TBKF040420 400 400 200 158 418 355 355 350 350 300 105 340 145 4 1

TBKF040620 400 600 200 158 418 355 555 350 550 500 105 540 145 4 1

TBKF040630 400 600 300 258 418 355 555 350 550 500 205 540 245 4 1

TBKF060420 600 400 200 158 618 555 355 550 350 300 105 340 145 4 1

TBKF060630 600 600 300 258 618 555 555 550 550 500 205 540 245 4 1

TBKF080620 800 600 200 158 818 755 555 750 550 500 105 540 145 6 2

TBKF080630 800 600 300 258 818 755 555 750 550 500 205 540 245 6 2

TBKF100620 1000 600 200 158 1018 955 555 950 550 500 105 540 145 6 2

TBKF120830 1200 800 300 258 1218 1155 755 1150 750 700 205 740 245 8 2

TBKF030215/G3

1 bottom gland plate,2 side gland plates

300 200 150 108 318 255 155 250 150 100 55 140 95 4 1

TBKF030420/G3 300 400 200 158 318 255 355 250 350 300 105 340 145 4 1

TBKF040315/G3 400 300 150 108 418 355 255 350 250 200 55 240 95 4 1

TBKF040420/G3 400 400 200 158 418 355 355 350 350 300 105 340 145 4 1

TBKF040620/G3 400 600 200 158 418 355 555 350 550 500 105 540 145 4 1

TBKF040630/G3 400 600 300 258 418 355 555 350 550 500 205 540 245 4 1

TBKF060420/G3 600 400 200 158 618 555 355 550 350 300 105 340 145 4 1

TBKF060630/G3 600 600 300 258 618 555 555 550 550 500 205 540 245 4 1

TBKF080620/G3 800 600 200 158 818 755 555 750 550 500 105 540 145 6 2

TBKF080630/G3 800 600 300 258 818 755 555 750 550 500 205 540 245 6 2

TBKF100620/G3 1000 600 200 158 1018 955 555 950 550 500 105 540 145 6 2

TBKF120830/G3 1200 800 300 258 1218 1155 755 1150 750 700 205 740 245 8 2

Terminal Size

Catalogue No.2.5mm2@ 20A

2.5mm2Derated to 10A

4mm2 @ 28A

6mm2@ 36A

10mm2@ 50A

35mm2 @ 109A

2.5mm2Instrumentation @ 1A

TBKF030215 13 50 10 9 8 5 25

TBKF030420 12 48 9 8 7 4 105

TBKF040315 11 46 9 8 7 4 110

TBKF040420 12 50 10 8 7 5 165

TBKF040620 13 50 10 9 8 5 275

TBKF040630 16 63 12 11 9 6 275

TBKF060420 16 63 12 11 9 6 275

TBKF060630 20 80 16 14 12 8 455

TBKF080620 19 78 16 14 12 8 455

TBKF080630 25 100 20 18 15 10 625

TBKF100620 23 93 18 16 14 10 790

TBKF120830 48 190 38 35 30 21 1110

TERMINAL INFORMATION (Reference Guide ONLY)

Please Note: • Other confi gurations and terminal sizes available, please contact your local B&R sales offi ce for evaluation and wattage calculations.• Quantities for instrumentation has been determined based on 1Amp with consideration to the size of the enclosure.

Term

inal

Box

es

! These enclosures are sold with controls and terminals fi tted. Empty enclosures are not available for sale.Contact your local sales engineer to discuss your specifi c requirements.

SELECTION GUIDE

Page 28: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

26 Hazardous Areas

FLAT ROOF TERMINAL BOXZONES 1 & 2, 21 & 22

IP65/66/67

MATERIALS• Body – 316 stainless steel• Body thickness – 1.5mm• Fixings – 316 stainless steel• Surface finish – N4

INCLUSIONS• Mounting flanges• External earth stud• Internal earth strap kit

CERTIFICATIONIECEx ITA 10.0023x

PROTECTIONEx e IIC T6 GbEx nA IIC T6 GcEx de IIC T6 GbEx tD A21/22 T80ºCDIP A21/22 Ta80ºCEx t IIIC T80ºC Db

AMBIENT TEMPERATURE-20ºC ~ +40ºC / 55ºC option

OVERVIEWThe flat roof screwed terminal box is made from 316 stainless steel and is suitable for use in hazardous areas with the most demanding conditions. These enclosures are suitable for Zones 1&2, 21&22 applications where flammable liquids, gases & vapours or combustible dusts are frequently present.

FEATURES• Customised etched identification label• Screwed lid• Mounting flanges• Mounting pan option available• External earth stud• Stainless steel fixings• Internal earth strap kit

TERMINAL INFORMATION (Reference Guide ONLY)

Terminal Size

Catalogue No.2.5mm2@ 20A

2.5mm2Derated to 10A

4mm2 @ 28A

6mm2@ 36A

2.5mm2Instrumentation @ 1A

TBSF010108 15 15 10 10 15

TBSF020212 12 20 12 10 20

TBSF030212 11 40 11 9 40

TBSF040212 12 45 9 8 50

TBSF060212 13 35 7 6 80

Please Note: • Other confi gurations and terminal sizes available, please contact your local B&R sales offi ce for evaluation and wattage calculations.• Quantities for instrumentation has been determined based on 1Amp with consideration to the size of the enclosure.• 10mm2 and 35mm2 available on request, cable / entry size to be considered.

Australian Made

Australian Owned

Page 29: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 27

FLAT ROOF TERMINAL BOXZONES 1 & 2, 21 & 22

Catalogue No.

Dimensions (mm) Fixings (mm) Opening

No. of FixingsHeight

(A)Width

(B)Depth

(C)Usable Depth

(D)Distance from Wall

(E)Height

(F)Width

(G)Height

(H)Width

(I)

TBSF010108 150 150 80 27 90 175 100 125 125 4

TBSF020212 200 200 120 67 130 225 150 175 175 4

TBSF030212 300 200 120 67 130 325 150 275 175 4

TBSF040212 400 200 120 67 130 425 150 375 175 4

TBSF060212 600 200 120 67 130 625 150 575 175 4

TECHNICAL DRAWINGS

▲ ▲B

▲ ▲G

F

A

ø8.5 hole size

6mm earth stud

Front View

▲ ▲I

H

Front View With Internals Side View

▲ ▲

▲ ▲C

E

▲ ▲D

Term

inal

Box

es

! These enclosures are sold with controls and terminals fi tted. Empty enclosures are not available for sale.Contact your local sales engineer to discuss your specifi c requirements.

SELECTION GUIDE

Page 30: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

28 Hazardous Areas

STAINLESS STEEL TERMINAL BOXZONES 1 & 2, 21 & 22

MATERIALS• Body – 316 stainless steel• Body thickness – 1.5mm• Fixings – 316 stainless steel• Surface finish – N4

INCLUSIONS• Mounting flanges• External earth stud• Internal earth strap kit

CERTIFICATIONIECEx ITA 10.0023x

PROTECTIONEx e IIC T6 GbEx nA IIC T6 GcEx de IIC T6 GbEx tD A21/22 T80ºCDIP A21/22 Ta80ºCEx t IIIC T80ºC Db

AMBIENT TEMPERATURE-20ºC ~ +55ºC

OVERVIEWThe flat roof screwed terminal box is made from 316 stainless steel and is suitable for use in hazardous areas with the most demanding conditions. These enclosures are suitable for Zones 1 & 2, 21 & 22 applications where flammable liquids, gases & vapours or combustible dust are frequently present.

FEATURES• Customised etched identification label• Screwed lid• Mounting flanges• Stainless steel fixings• Earth strap kit• Optional steel mounting pan

IP65/66

Australian Made

Australian Owned

Page 31: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 29

STAINLESS STEEL TERMINAL BOXZONES 1 & 2, 21 & 22

Catalogue No.

External Dimensions (mm) Fixings (mm) Lid Fixings (mm)

DescriptionHeight

(A)Width

(B)Depth

(C)Distance from wall

(D)Height

(E)Width

(F)Height

(G)Width

(H)

TBSFCS11 Single gang 112 90 90 91 132 67 77 73

TBSFCS12 Double gang 159 90 90 91 179 67 124 73

TBSFCS13 Three gang 205 90 90 91 225 67 170 73

TBSFCS14 Four gang 250 90 90 91 270 67 215 73

TBSFCS16 Six gang 343 90 90 91 363 67 308 73

TECHNICAL DRAWINGS

Front View

▲ ▲F▲ ▲H

▲ ▲B

G

E

A

Side View

G

▲ ▲D▲ ▲C

Section View

Term

inal

Box

es

! These enclosures are sold with controls and terminals fi tted. Empty enclosures are not available for sale.Contact your local sales engineer to discuss your specifi c requirements.

SELECTION GUIDE

Page 32: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

30 Hazardous Areas

SLOPING ROOF CUSTOM BUILT CONTROL BOXZONES 1 & 2, 21 & 22

CERTIFICATIONIECEx ITA 10.0023x

PROTECTIONEx e IIC T6 GbEx nA IIC T6 Gb, Zone 2 onlyEx de IIC T6 GbEx tD A21/22 T80ºCDIP A21/22 Ta80ºCEx t IIIC T80ºC Db

AMBIENT TEMPERATURE-20ºC ~ +40ºC (to +55ºC)

IP65/66

MATERIALS• Body – 316 stainless steel• Body thickness – 1.5mm• Fixings – 316 stainless steel• Surface finish – N4

INCLUSIONS• Steel mounting pan• 7mm stainless steel lock• External mounting flange• Internal and external 6mm or 8mm

earth stud• 3mm stainless steel gland plate• Earth strap kit• No gland plate option

OVERVIEWSuitable for use in hazardous areas with the most demanding conditions. The 40º sloping roof minimises the build up of solids on the roof of the enclosure. The 40mm overhang ensures material that slides off the roof is directed away from the top of the door.

FEATURES• Customised etched identification label• 40º sloping roof and 40mm overhang• Keyed entry with 7mm stainless steel square lock• Other labelling options available• Threaded entries in gland plate versions• IP66 windows available• Brass gland plate option with up to 3 gland plates available

CONTROLS / OPERATORSOther controls / operators are available including:

• Pushbuttons• Isolating switches• Key switches• Pilot lights• Ammeters• Circuit breakers• Motor starters• Viewing windows

Australian Made

Australian Owned

Page 33: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 31

SLOPING ROOF CUSTOM BUILT CONTROL BOXZONES 1 & 2, 21 & 22

Dimensions (mm)

External Mounting Centres Opening Usable Depth Mounting Pan Gland Opening Gland PlateNo of

locksCatalogue No. Description A B C D E F G H I J K L M Width Depth

CBKS030215/G0

No gland plate

300 200 150 550 510 100 255 155 105 250 150 – – – – 1

CBKS030420/G0 300 400 200 610 570 300 255 355 155 250 350 – – – – 1

CBKS040315/G0 400 300 150 650 610 200 355 255 105 350 250 – – – – 1

CBKS040420/G0 400 400 200 710 670 300 355 355 155 350 350 – – – – 1

CBKS040620/G0 400 600 200 710 670 500 355 555 155 350 550 – – – – 1

CBKS040630/G0 400 600 300 795 755 500 355 555 255 350 550 – – – – 1

CBKS060420/G0 600 400 200 910 870 300 555 355 155 550 350 – – – – 1

CBKS060630/G0 600 600 300 995 955 500 555 555 255 550 550 – – – – 1

CBKS080620/G0 800 600 200 1110 1070 500 755 555 155 750 550 – – – – 2

CBKS080630/G0 800 600 300 1195 1155 500 755 555 255 750 550 – – – – 2

CBKS100620/G0 1000 600 200 1310 1270 500 955 555 155 950 550 – – – – 2

CBKS120830/G0 1200 800 300 1595 1555 700 1155 755 255 1150 750 – – – – 2

CBKS030215

1 x bottom gland plate

300 200 150 550 510 100 255 155 105 250 150 100 55 140 95 1

CBKS030420 300 400 200 610 570 300 255 355 155 250 350 300 105 340 145 1

CBKS040315 400 300 150 650 610 200 355 255 105 350 250 200 55 240 95 1

CBKS040420 400 400 200 710 670 300 355 355 155 350 350 300 105 340 145 1

CBKS040620 400 600 200 710 670 500 355 555 155 350 550 500 105 540 145 1

CBKS040630 400 600 300 795 755 500 355 555 255 350 550 500 205 540 245 1

CBKS060420 600 400 200 910 870 300 555 355 155 550 350 300 105 340 145 1

CBKS060630 600 600 300 995 955 500 555 555 255 550 550 500 205 540 245 1

CBKS080620 800 600 200 1110 1070 500 755 555 155 750 550 500 105 540 145 2

CBKS080630 800 600 300 1195 1155 500 755 555 255 750 550 500 205 540 245 2

CBKS100620 1000 600 200 1310 1270 500 955 555 155 950 550 500 105 540 145 2

CBKS120830 1200 800 300 1595 1555 700 1155 755 255 1150 750 700 205 740 245 2

CBKS030215/G3

1 bottom gland plate,2 side gland plates

300 200 150 550 510 100 255 155 105 250 150 100 55 140 95 1

CBKS030420/G3 300 400 200 610 570 300 255 355 155 250 350 300 105 340 145 1

CBKS040315/G3 400 300 150 650 610 200 355 255 105 350 250 200 55 240 95 1

CBKS040420/G3 400 400 200 710 670 300 355 355 155 350 350 300 105 340 145 1

CBKS040620/G3 400 600 200 710 670 500 355 555 155 350 550 500 105 540 145 1

CBKS040630/G3 400 600 300 795 755 500 355 555 255 350 550 500 205 540 245 1

CBKS060420/G3 600 400 200 910 870 300 555 355 155 550 350 300 105 340 145 1

CBKS060630/G3 600 600 300 995 955 500 555 555 255 550 550 500 205 540 245 1

CBKS080620/G3 800 600 200 1110 1070 500 755 555 155 750 550 500 105 540 145 2

CBKS080630/G3 800 600 300 1195 1155 500 755 555 255 750 550 500 205 540 245 2

CBKS100620/G3 1000 600 200 1310 1270 500 955 555 155 950 550 500 105 540 145 2

CBKS120830/G3 1200 800 300 1595 1555 700 1155 755 255 1150 750 700 205 740 245 2

TECHNICAL DRAWINGS

Bottom View With Internals

▲ ▲L

M

Front View Side ViewWith Internals

▲▲

C

I

▲40

▲16▲

A

D

▲ ▲▲F

A

E

B

Is indicative of lock position when there is only one lock on enclosures

Front ViewWith Internals

G

▲▲ H

▲ ▲K

J

Con

trol

Box

es

! These enclosures are sold with controls and terminals fi tted. Empty enclosures are not available for sale.Contact your local sales engineer to discuss your specifi c requirements.

SELECTION GUIDE

Page 34: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

32 Hazardous Areas

FLAT ROOF CUSTOM BUILT CONTROL BOXZONES 1 & 2, 21 & 22

CERTIFICATIONIECEx ITA 10.0023x

PROTECTIONEx e IIC T6 GbEx nA IIC T6 GcEx de IIC T6 GbEx tD A21/22 T80ºCDIP A21/22 Ta80ºCEx t IIIC T80ºC Db

AMBIENT TEMPERATURE-20ºC ~ +40ºC / 55ºC option

Australian Made

Australian Owned

MATERIALS• Body – 316 stainless steel• Body thickness – 1.5mm• Fixings – 316 stainless steel• Surface finish – N4

INCLUSIONS• Steel mounting pan• 3mm stainless steel or 6mm brass

gland plate• 7mm stainless steel lock• Internal and external 6mm or 8mm

earth stud• Earth strap kit• Stainless steel label bracket

OVERVIEWThe flat roof keyed control box is made from 316 stainless steel and is suitable for use in hazardous areas with the most demanding conditions. The enclosures are suitable forZones 1 & 2, 21 & 22 applications where flammable liquids, gases & vapours or combustible dusts are frequently present

CONTROLS / OPERATORSOther controls / operators are available including:

• Pushbuttons• Isolating switches• Key switches• Pilot lights• Ammeters• Circuit breakers• Motor starters• Viewing windows

FEATURES• Customised etched identification label• Keyed entry with 7mm square stainless steel lock• Steel mounting pan• Internal and external 6mm earth stud, 8mm option• Replaceable gaskets• Wall-mounting brackets – M8 fixings• Other label options available• Threaded entries on gland plate versions• IP66 windows availble• Brass gland plate option up to 3 gland plates available

IP65/66

Page 35: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 33

FLAT ROOF CUSTOM BUILT CONTROL BOXZONES 1 & 2, 21 & 22

Dimensions (mm)

External Opening Mounting Pan Gland Opening Gland PlateWall Mount

BracketsNo of LocksCatalogue No. Description A B C D E F G H I J K Width Depth

CBKF030215/G0

No gland plate

300 200 150 108 – 255 155 250 150 – – – – 4 1

CBKF030420/G0 300 400 200 158 – 255 355 250 350 – – – – 4 1

CBKF040315/G0 400 300 150 108 – 355 255 350 250 – – – – 4 1

CBKF040420/G0 400 400 200 158 – 355 355 350 350 – – – – 4 1

CBKF040620/G0 400 600 200 158 – 355 555 350 550 – – – – 4 1

CBKF040630/G0 400 600 300 258 – 355 555 350 550 – – – – 4 1

CBKF060420/G0 600 400 200 158 – 555 355 550 350 – – – – 4 1

CBKF060630/G0 600 600 300 258 – 555 555 550 550 – – – – 4 1

CBKF080620/G0 800 600 200 158 – 755 555 750 550 – – – – 6 2

CBKF080630/G0 800 600 300 258 – 755 555 750 550 – – – – 6 2

CBKF100620/G0 1000 600 200 158 – 955 555 950 550 – – – – 6 2

CBKF120830/G0 1200 800 300 258 – 1155 755 1150 750 – – – – 8 2

CBKF030215

1 x bottom gland plate

300 200 150 108 318 255 155 250 150 100 55 140 95 4 1

CBKF030420 300 400 200 158 318 255 355 250 350 300 105 340 145 4 1

CBKF040315 400 300 150 108 418 355 255 350 250 200 55 240 95 4 1

CBKF040420 400 400 200 158 418 355 355 350 350 300 105 340 145 4 1

CBKF040620 400 600 200 158 418 355 555 350 550 500 105 540 145 4 1

CBKF040630 400 600 300 258 418 355 555 350 550 500 205 540 245 4 1

CBKF060420 600 400 200 158 618 555 355 550 350 300 105 340 145 4 1

CBKF060630 600 600 300 258 618 555 555 550 550 500 205 540 245 4 1

CBKF080620 800 600 200 158 818 755 555 750 550 500 105 540 145 6 2

CBKF080630 800 600 300 258 818 755 555 750 550 500 205 540 245 6 2

CBKF100620 1000 600 200 158 1018 955 555 950 550 500 105 540 145 6 2

CBKF120830 1200 800 300 258 1218 1155 755 1150 750 700 205 740 245 8 2

CBKF030215/G3

1 bottom gland plate,2 side gland plates

300 200 150 108 318 255 155 250 150 100 55 140 95 4 1

CBKF030420/G3 300 400 200 158 318 255 355 250 350 300 105 340 145 4 1

CBKF040315/G3 400 300 150 108 418 355 255 350 250 200 55 240 95 4 1

CBKF040420/G3 400 400 200 158 418 355 355 350 350 300 105 340 145 4 1

CBKF040620/G3 400 600 200 158 418 355 555 350 550 500 105 540 145 4 1

CBKF040630/G3 400 600 300 258 418 355 555 350 550 500 205 540 245 4 1

CBKF060420/G3 600 400 200 158 618 555 355 550 350 300 105 340 145 4 1

CBKF060630/G3 600 600 300 258 618 555 555 550 550 500 205 540 245 4 1

CBKF080620/G3 800 600 200 158 818 755 555 750 550 500 105 540 145 6 2

CBKF080630/G3 800 600 300 258 818 755 555 750 550 500 205 540 245 6 2

CBKF100620/G3 1000 600 200 158 1018 955 555 950 550 500 105 540 145 6 2

CBKF120830/G3 1200 800 300 258 1218 1155 755 1150 750 700 205 740 245 8 2

TECHNICAL DRAWINGS

Front View

A

▲ ▲B

Is indicative of lock position when there is one lock on enclosure

Front ViewWith Internals

Side View

E

G

▲ ▲H

Bottom View

▲ ▲C

D

Con

trol

Box

es

! These enclosures are sold with controls and terminals fi tted. Empty enclosures are not available for sale.Contact your local sales engineer to discuss your specifi c requirements.

SELECTION GUIDE

Page 36: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

34 Hazardous Areas

FLAT ROOF CUSTOM BUILT CONTROL BOXZONES 1 & 2, 21 & 22

Australian Made

Australian Owned

MATERIALS• Body – 316 stainless steel• Body thickness – 1.5mm• Fixings – 316 stainless steel• Surface finish – N4

INCLUSIONS• Mounting flanges• External earth stud• Internal earth strap kit

CERTIFICATIONIECEx ITA 10.0023x

PROTECTIONEx e IIC T6 GbEx nA IIC T6 GcEx de IIC T6 GbEx tD A21/22 T80ºCDIP A21/22 Ta80ºCEx t IIIC T80ºC Db

AMBIENT TEMPERATURE-20ºC ~ +40ºC / 55ºC option

OVERVIEWThe flat roof screwed terminal box is made from 316 stainless steel and is suitable for use in hazardous areas with the most demanding conditions. These enclosures are suitable for Zones 1 & 2, 21 & 22 applications where flammable liquids, gases & vapours or combustible dusts are frequently present.

FEATURES• Customised etched identification label• Screwed lid• Mounting flanges• Mounting pan option available• External earth stud• Stainless steel fixings• Internal earth strap kit

IP65/66

Page 37: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 35

FLAT ROOF CUSTOM BUILT CONTROL BOXZONES 1 & 2, 21 & 22

Catalogue No.

Dimensions (mm) Fixings (mm) Opening

No. of FixingsHeight

(A)Width

(B)Depth

(C)Usable Depth

(D)Distance from Wall

(E)Height

(F)Width

(G)Height

(H)Width

(I)

CBSF010108 150 150 80 27 90 175 100 125 125 4

CBSF020212 200 200 120 67 130 225 150 175 175 4

CBSF030212 300 200 120 67 130 325 150 275 175 4

CBSF040212 400 200 120 67 130 425 150 375 175 4

CBSF060212 600 200 120 67 130 625 150 575 175 4

▲ ▲B

▲ ▲G

F

A

ø8.5 hole size

6mm earth stud

Front View

▲ ▲I

H

Front View With Internals Side View

▲ ▲

▲ ▲C

E

▲ ▲D

TECHNICAL DRAWINGS

Con

trol

Box

es

! These enclosures are sold with controls and terminals fi tted. Empty enclosures are not available for sale.Contact your local sales engineer to discuss your specifi c requirements.

SELECTION GUIDE

Page 38: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

36 Hazardous Areas

IP66

STAINLESS STEEL CONTROL STATIONZONES 1 & 2, 21 & 22

Australian Made

Australian Owned

MATERIALS• Body – 316 stainless steel• Body thickness – 1.5mm• Gasket – Replaceable• Fixings – 316 stainless steel• Surface finish – N4• Components – Certified switch mechanisms, ammeter available

INCLUSIONS• Earth strap kit

CERTIFICATIONIECEx ITA 10.0023x

PROTECTIONEx e IIC T6 GbEx nA IIC T6 GcEx de IIC T6 GbEx tD A21/22 T80ºCDIP A21/22 Ta80ºCEx t IIIC T80ºC Db

AMBIENT TEMPERATURE-20ºC ~ +40ºC / 55ºC option

OVERVIEWControl stations are manufactured from 316 stainless steel. These control stations are available pre-configured or custom-built for ease of installation from one to six operators.

FEATURES• Customised etched identification label• Screwed lid• Mounting flanges• Stainless steel fixings• Earth strap kit

TECHNICAL DRAWINGS

Front View

▲ ▲B

A

Side View

▲ ▲C

Section View

Page 39: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 37

Dimensions (mm)

Catalogue No. Type PoleHeight

(A)Width

(B)Depth

(C) Description

CSS1-P1GRN

Pushbutton

– 112 90 90 1NO+1NC, Start, Green

CSS1-P1RED – 112 90 90 1NO+1NC, Stop, Red

CSS1-P3MH – 112 90 90 1NO+1NC, emergency stop self-locking

CSS1-P2 – 112 90 90 1NO+1NC, double button, Stop-Start

CSS1-P4 – 112 90 90 1NO+1NC, mushroom head button, Black

CSS2-PGPR – 159 90 90 1NO+1NC, 2 pushbuttons Green/Red

CSS3-PGPRPB – 159 90 90 1NO+1NC, 3 pushbuttons Green/Red/Black

CSS2-P1GRNLR

Pushbutton& Lamp

– 159 90 90 1NO+1NC, Start, lamp, Red

CSS2-P1REDLR – 159 90 90 1NO+1NC, Stop, lamp, Red

CSS2-P1GRNLG – 159 90 90 1NO+1NC, Start, lamp, Green

CSS2-P1REDLG – 159 90 90 1NO+1NC, Stop, lamp, Green

CSS2-P2GRNLY – 159 90 90 1NO+1NC, Start, lamp, Yellow

CSS2-P1REDLY – 159 90 90 1NO+1NC, Stop, lamp, Yellow

CSS2-P1GRNLB – 159 90 90 1NO+1NC, Start, lamp, Blue

CSS2-P1REDLB – 159 90 90 1NO+1NC, Stop, lamp, Blue

CSS2-P1GRNLW – 159 90 90 1NO+1NC, Start, lamp, White

CSS2-P1REDLW – 159 90 90 1NO+1NC, Stop, lamp, White

CSS3-PGPRLR

Double Pushbuttonw/ Lamp

– 205 90 90 1NO+1NC, 2 pushbuttons Green/Red, lamp Red

CSS3-PGPRLG – 205 90 90 1NO+1NC, 2 pushbuttons Green/Red, lamp Green

CSS3-PGPRLY – 205 90 90 1NO+1NC, 2 pushbuttons Green/Red, lamp Yellow

CSS3-PGPRLB – 205 90 90 1NO+1NC, 2 pushbuttons Green/Red, lamp Blue

CSS3-PGPRLW – 205 90 90 1NO+1NC, 2 pushbuttons Green/Red, lamp White

CSS3-P2P3MHLR – 205 90 90 2NC, double pushbutton Red, emergency lamp Red

CSS3-P2P3MHLG – 205 90 90 2NC, double pushbutton Red, emergency lamp Green

CSS3-P2P3MHLY – 205 90 90 2NC, double pushbutton Red, emergency lamp Yellow

CSS3-P2P3MHLB – 205 90 90 2NC, double pushbutton Red, emergency lamp Blue

CSS3-P2P3MHLW – 205 90 90 2NC, double pushbutton Red, emergency lamp White

CSS1-LR

Lamp

– 112 90 90 AC24~240V, single lamp, Red

CSS1-LG – 112 90 90 AC24~240V, single lamp, Green

CSS1-LY – 112 90 90 AC24~240V, single lamp, Yellow

CSS1-LB – 112 90 90 AC24~240V, single lamp, Blue

CSS1-LW – 112 90 90 AC24~240V, single lamp, White

CSS2-P2LR

Double Lamp

– 159 90 90 1NO+1NC, AC24~240V, double pushbutton, lamp Red

CSS2-P2LG – 159 90 90 1NO+1NC, AC24~240V, double pushbutton, lamp Green

CSS2-P2LY – 159 90 90 1NO+1NC, AC24~240V, double pushbutton, lamp Yellow

CSS2-P2LB – 159 90 90 1NO+1NC, AC24~240V, double pushbutton, lamp Blue

CSS2-P2LW – 159 90 90 1NO+1NC, AC24~240V, double pushbutton, lamp White

CSS3-P2LR – 175 86 76 1NO+1NC, Red

CSS3-P2LG – 175 86 76 1NO+1NC, Green

CSS3-P2LY – 175 86 76 1NO+1NC, Yellow

CSS3-P2LB – 175 86 76 1NO+1NC, Blue

CSS3-P2LW – 175 86 76 1NO+1NC, White

CSS1-K6

Switch

2-p 112 90 90 Small handle, Ø39mm

CSS2-S6 2-p 159 90 90 Large handle, Ø60mm

CSS2-S6H4 4-p 159 90 90 2NO+2NC, LL 0

STAINLESS STEEL CONTROL STATIONZONES 1 & 2, 21 & 22

Con

trol

Box

es

! These enclosures are sold with controls and terminals fi tted. Empty enclosures are not available for sale.Contact your local sales engineer to discuss your specifi c requirements.

SELECTION GUIDE

Page 40: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

38 Hazardous Areas

MATERIALS• Body – GRP UV stabilised anti-static• Stainless steel screws• Internal gland plate• Surface finish – Textured matt black

INCLUSIONS• Standard built product• Internal brass gland plates

CERTIFICATIONIECEx CQM 13.0017

PROTECTIONEx ed IIC T6Ex tD A21 IP66 T80ºC

AMBIENT TEMPERATURE-40≤Ta≤40ºC

OVERVIEWRange of standard control stations that can be combined into one unit using a maximum of six in configurations to suit the application requirements. They are light-weight, impact resistant and are suitable for use in hazardous areas where stainless steel is not a requirement.

FEATURES• Can be customised to suit requirements• UV stabilised anti-static construction• Five standard controllers in one• Easy installation• Flexible configurations• High chemical stability

IP66

Front View Side View

▲ ▲▲ ▲B c

▲ ▲E

A D

TECHNICAL DRAWINGS

NON-METALLIC CONTROL STATIONZONES 1 & 2, 21 & 22

Page 41: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 39

Dimensions (mm) Mounting Centres (mm)

Catalogue No. PoleHeight

(A)Width

(B)Depth

(C)Height

(D)Width

(E) Description

CSG1-P1GRN

Pushbutton

– 95 86 76 58 73 1NO+1NC, Start, Green

CSG1-P1RED – 95 86 76 58 73 1NO+1NC, Stop, Red

CSG1-P3MH – 95 86 76 58 73 1NO+1NC, emergency stop self-locking,

CSG1-P2 – 95 86 76 58 73 1NO+1NC, double button, Stop-Start

CSG1-P4 – 95 86 76 58 73 1NO+1NC, mushroom head button, Black

CSG2-PGPR – 135 86 76 98 73 1NO+1NC, 2 pushbuttons

CSG3-PGPRPB – 135 86 76 98 73 1NO+1NC, 3 pushbuttons

CSG2-P1GRNLR

Pushbutton& Lamp

– 135 86 76 98 73 1NO+1NC, Start, lamp, Red

CSG2-P1REDLR – 135 86 76 98 73 1NO+1NC, Stop, lamp, Red

CSG2-P1GRNLG – 135 86 76 98 73 1NO+1NC, Start, lamp, Green

CSG2-P1REDLG – 135 86 76 98 73 1NO+1NC, Stop, lamp, Green

CSG2-P2GRNLY – 135 86 76 98 73 1NO+1NC, Start, lamp, Yellow

CSG2-P1REDLY – 135 86 76 98 73 1NO+1NC, Stop, lamp, Yellow

CSG2-P1GRNLB – 135 86 76 98 73 1NO+1NC, Start, lamp, Blue

CSG2-P1REDLB – 135 86 76 98 73 1NO+1NC, Stop, lamp, Blue

CSG2-P1GRNLW – 135 86 76 98 73 1NO+1NC, Start, lamp, White

CSG2-P1REDLW – 135 86 76 98 73 1NO+1NC, Stop, lamp, White

CSG3-PGPRLR – 175 86 76 138 73 1NO+1NC, 2 pushbuttons, lamp, Red

CSG3-PGPRLG – 175 86 76 138 73 1NO+1NC, 2 pushbuttons, lamp, Green

CSG3-PGPRLY – 175 86 76 138 73 1NO+1NC, 2 pushbuttons, lamp, Yellow

CSG3-PGPRLB – 175 86 76 138 73 1NO+1NC, 2 pushbuttons, lamp, Blue

CSG3-PGPRLW – 175 86 76 138 73 1NO+1NC, 2 pushbuttons, lamp, White

CSG3-P2P3MHLR

Double Pushbuttonw/ Lamp

– 175 86 76 138 73 2NC, Red emergency lamp, Red

CSG3-P2P3MHLG – 175 86 76 138 73 2NC, Red emergency lamp, Green

CSG3-P2P3MHLY – 175 86 76 138 73 2NC, Red emergency lamp, Yellow

CSG3-P2P3MHLB – 175 86 76 138 73 2NC, Red emergency lamp, Blue

CSG3-P2P3MHLW – 175 86 76 138 73 2NC, Red emergency lamp, White

CSG1-LR

Lamp

– 95 86 76 58 73 AC24~240V, single lamp, Red

CSG1-LG – 95 86 76 58 73 AC24~240V, single lamp, Green

CSG1-LY – 95 86 76 58 73 AC24~240V, single lamp, Yellow

CSG1-LB – 95 86 76 58 73 AC24~240V, single lamp, Blue

CSG1-LW – 95 86 76 58 73 AC24~240V, single lamp, White

CSG2-P2LR

Double Pushbutton

– 135 86 76 98 73 1NO+1NC, AC24~240V, double lamp, Red

CSG2-P2LG – 135 86 76 98 73 1NO+1NC, AC24~240V, double lamp, Green

CSG2-P2LY – 135 86 76 98 73 1NO+1NC, AC24~240V, double lamp, Yellow

CSG2-P2LB – 135 86 76 98 73 1NO+1NC, AC24~240V, double lamp, Blue

CSG2-P2LW – 135 86 76 98 73 1NO+1NC, AC24~240V, double lamp, White

CSG3-P2LR – 175 86 76 138 73 1NO+1NC, Red

CSG3-P2LG – 175 86 76 138 73 1NO+1NC, Green

CSG3-P2LY – 175 86 76 138 73 1NO+1NC, Yellow

CSG3-P2LB – 175 86 76 138 73 1NO+1NC, Blue

CSG3-P2LW – 175 86 76 138 73 1NO+1NC, White

CSG1-K6

Switch

2-p 95 86 76 58 73 Small handle, Ø39mm

CSG2-S6 2-p 135 86 76 98 73 Large handle, Ø60mm

CSG2-S6H4 4-p 135 86 76 138 73 2NO+2NC, LL 0

Non

-Met

allic

Encl

osur

es

SELECTION GUIDE

NON-METALLIC CONTROL STATIONZONES 1 & 2, 21 & 22

Page 42: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

40 Hazardous Areas

MATERIALS• Body – GRP anti-static• Surface finish – Textured matt black

INCLUSIONS• Custom built to suit requirements

CERTIFICATIONIECEx CQM 13.0016x

PROTECTIONEx e II T6/T5 GbEx tD A21 IP65 T95ºC ~ T80ºC

AMBIENT TEMPERATURE-40ºC + 40ºC / 55ºC option

OVERVIEWA range of non-metallic enclosures which are impact resistant, withstand high or low termperatures and are static resistant. These terminal boxes are suitable for use in hazardous area environments to provide the ultimate in flexibility and are easy to wire and mount. A complete arrangement of terminals can be fitted ranging from 2.5mm to 300mm. The enclosure can also cater for IS terminals.

FEATURES• Earth plate for cable gland entries• Used for terminating wires for various electrical apparatus

and instruments in circuits• Can be used with with IS terminations• Ex e models must use component certified terminals

IP65

TECHNICAL DRAWINGS

Front View Side View

A

▲ ▲▲ ▲B C

NON-METALLIC TERMINAL BOXZONES 1 & 2, 21 & 22

Page 43: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 41

Dimensions (mm) Entries Terminals

Catalogue No.Height

(A)Width

(B)Depth

(C) SizeFrom sideA, B or Z, Y

From sideC, D or S, X No. of Rows 2.5mm 4mm 6mm 10mm 16mm 32mm

TBG001 122 122 96

TBG011 170 122 96

M20 6 4

M25 4 2

M32 2 1 1 14 13 10 8 6 4

M40 2 1

M50 1 1

TBG031 220 134

M20 8 4

M25 5 2

96 M32 3 2 1 23 22 17 13 11 7

M40 3 1

M50 2 1

TBG032 220 134 141

M20 12 6

M25 8 5

M32 6 3

M40 4 2 1 14 13 10 8 6 4

M50 2 1

M63 2 1

TBG051 275 160 96

M20 10 6

M25 10 4

M32 5 2 1 31 29 23 19 16 10

M40 4 2

M50 3 1

TBG052

TBG053

TBG054

275

275

275

160

160

160

161

226

166

M20 24 12

M25 15 9

M32 11 5 1 14 13 10 8 6 4

M40 6 3

M50 5 2

M63 3 1

TBG071 352 234 96

M20 16 10

M25 10 6

M32 7 4 1 43 40 32 26 22 14

M40 5 3

M50 4 2

TBG072

TBG073

TBG074

352

352

352

234

234

234

161

231

166

M20 32 18

M25 21 12

M32 14 8

M40 10 6 1 43 40 32 26 22 14

M50 4 3

M63 4 2

TBG081 352 352 96

M20 16 16

M25 10 10 1 43 40 32 26 22 14

M32 7 7 2 86 80 64 52 44 28

M40 5 5

M50 4 4

TBG082

TBG083

TBG084

TBG085

352

352

352

352

352

352

352

352

161

231

136

166

M20 32 32

M25 21 21

M32 14 14 3 129 120 96 78 66 42

M40 10 10

M50 4 4

M63 4 4

TBG092

TBG093

TBG094

706

706

706

352

352

352

161

231

201

M20 64 32

M25 42 21

M32 28 14 1 86 80 64 52 44 28

M40 20 10 2 172 160 128 104 88 56

M50 12 6

M63 8 4

Non

-Met

allic

Encl

osur

es

! These enclosures are sold with controls and terminals fi tted. Empty enclosures are not available for sale.Contact your local sales engineer to discuss your specifi c requirements.

SELECTION GUIDE

NON-METALLIC TERMINAL BOXZONES 1 & 2, 21 & 22

Page 44: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

42 Hazardous Areas

NON-METALLIC TERMINAL BOXZONES 1 & 2, 21 & 22

MATERIALS• Body – GRP anti-static• Surface finish – Textured matt black

INCLUSIONS• Built in terminal box• Brass gland plate• Certified plugs• Custom built to suit requirements

CERTIFICATIONIECEx CQM 13.0015x

PROTECTIONEx e II T6 GbEx tD A21 T80ºC

AMBIENT TEMPERATURE-40ºC ≤ Ta ≤ +40ºC

OVERVIEWA range of non-metallic enclosures which are impact resistant, withstand high or low termperatures and static resistant. These terminal boxes are suitable for use in hazardous area environments, provide the ultimate in flexibility and are easy to wire and mount.

FEATURES• Impact and static resistant• Withstand high or low temperatures• Cable can connect to terminals from different directions

IP66

TECHNICAL DRAWINGS

A

▲ ▲B

▲ ▲C

Front View Side View

Page 45: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 43

Dimensions (mm) Entries Terminals

Catalogue No. Protection TypeHeight

(A)Width

(B)Depth

(C) Qty Size (mm) Location Qty Size (mm)

TBGS21ET2.5X4/220N

Ex e

95 95 62.5 2 20 Opposite sides 4 2.5

TBGS21ET2.5X4/420X 95 95 62.5 4 20 One each side 4 2.5

TBGS21ET2.5X4/225N 95 95 62.5 2 25 Opposite sides 4 2.5

TBGS21ET2.5X4/425X 95 95 62.5 4 25 One each side 4 2.5

TBGS22ET2.5X8/220N 125 125 69.5 2 20 Opposite sides 8 2.5

TBGS22ET2.5X8/420X 125 125 69.5 4 20 One each side 8 2.5

TBGS22ET2.5X8/225N 125 125 69.5 2 25 Opposite sides 8 2.5

TBGS22ET2.5X8/425X 125 125 69.5 4 25 One each side 8 2.5

TBGS22ET4X4/220N 125 125 69.5 2 20 Opposite sides 4 4

TBGS22ET4X4/420X 125 125 69.5 4 20 One each side 4 4

TBGS22ET4X4/225N 125 125 69.5 2 25 Opposite sides 4 4

TBGS22ET4X4/425X 125 125 69.5 4 25 One each side 4 4

TBGS21TT2.5X4/220N

Ex t

95 95 62.5 2 20 Opposite sides 4 2.5

TBGS21TT2.5X4/420X 95 95 62.5 4 20 One each side 4 2.5

TBGS21TT2.5X4/225N 95 95 62.5 2 25 Opposite sides 4 2.5

TBGS21TT2.5X4/425X 95 95 62.5 4 25 One each side 4 2.5

TBGS22TT2.5X8/220N 125 125 69.5 2 20 Opposite sides 8 2.5

TBGS22TT2.5X8/420X 125 125 69.5 4 20 One each side 8 2.5

TBGS22TT2.5X8/225N 125 125 69.5 2 25 Opposite sides 8 2.5

TBGS22TT2.5X8/425X 125 125 69.5 4 25 One each side 8 2.5

TBGS22TT4X4/220N 125 125 69.5 2 20 Opposite sides 4 4

TBGS22TT4X4/420X 125 125 69.5 4 20 One each side 4 4

TBGS22TT4X4/225N 125 125 69.5 2 25 Opposite sides 4 4

TBGS22TT4X4/425X 125 125 69.5 4 25 One each side 4 4

TBGS21IT2.5X4/220N

Ex i

95 95 62.5 2 20 Opposite sides 4 2.5

TBGS21IT2.5X4/420X 95 95 62.5 4 20 One each side 4 2.5

TBGS21IT2.5X4/225N 95 95 62.5 2 25 Opposite sides 4 2.5

TBGS21IT2.5X4/425X 95 95 62.5 4 25 One each side 4 2.5

TBGS22IT2.5X8/220N 125 125 69.5 2 20 Opposite sides 8 2.5

TBGS22IT2.5X8/420X 125 125 69.5 4 20 One each side 8 2.5

TBGS22IT2.5X8/225N 125 125 69.5 2 25 Opposite sides 8 2.5

TBGS22IT2.5X8/425X 125 125 69.5 4 25 One each side 8 2.5

NON-METALLIC TERMINAL BOXZONES 1 & 2, 21 & 22

SELECTION GUIDE

! These enclosures are sold with controls and terminals fi tted. Empty enclosures are not available for sale.Contact your local sales engineer to discuss your specifi c requirements.

Non

-Met

allic

Encl

osur

es

Page 46: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.
Page 47: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

Lig

hti

ng

Page 48: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

46 Hazardous Areas

Range:BAY-D Series

OVERVIEWSuitable for Zones 1 & 2 applications. These light fittings can be used as a standard light during normal operations that automatically switches to emergency state (engages emergency battery) when there is a loss of power.

FEATURES• Long-life energy saving LED• Emergency duration 180 minutes• Power consumption – 2W

• MATERIALS

• Body – Die cast aluminium• Diffuser – Toughened glass• Surface finish – Epoxy powdercoated yellow• Rated voltage – AC220 –240V, 50Hz

INCLUSIONS• 1 x M20 cable gland entries• Inner control circuit with over charge protection• LED lamp• Direction sign (various options available)

CERTIFICATIONIECEx LCI 08.0021x

PROTECTIONEx d IIC T6

AMBIENT TEMPERATURE-20ºC ~ +55ºC

IP65

A-Type

E-Type

B-Type

F-Type

C-Type

G-Type

D-Type

DIRECTIONAL SIGN OPTIONS

ALUMINIUM EMERGENCY LED EXIT LIGHTZONES 1 & 2

Page 49: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 47

Catalogue No.

Direction Sign External Dimensions (mm) Mounting Centres (mm)

Sign TypeHeight

(A)Width

(B)Depth

(D)Width

(E)Height

(C) Mounting Type Weight (kg)

EEALD/BA A-Type 210 507 110 200 126

Wall

6.4

EEALD/BB B-Type 210 507 110 200 126 6.4

EEALD/BC C-Type 210 507 110 200 126 6.4

EEALD/BD D-Type 210 507 110 200 126 6.4

EEALD/BE E-Type 210 507 110 200 126 6.4

EEALD/BF F-Type 210 507 110 200 126 6.4

EEALD/BG G-Type 210 507 110 200 126 6.4

EEALD/XA A-Type 255 507 110 200 50

Ceiling

6.4

EEALD/XB B-Type 255 507 110 200 50 6.4

EEALD/XC C-Type 255 507 110 200 50 6.4

EEALD/XD D-Type 255 507 110 200 50 6.4

EEALD/XE E-Type 255 507 110 200 50 6.4

EEALD/XF F-Type 255 507 110 200 50 6.4

EEALD/XG G-Type 255 507 110 200 50 6.4

EEALD/GA A-Type 715 430 110 – 440

Pendant pole

6.4

EEALD/GB B-Type 715 430 110 – 440 6.4

EEALD/GC C-Type 715 430 110 – 440 6.4

EEALD/GD D-Type 715 430 110 – 440 6.4

EEALD/GE E-Type 715 430 110 – 440 6.4

EEALD/GF F-Type 715 430 110 – 440 6.4

EEALD/GG G-Type 715 430 110 – 440 6.4

SELECTION GUIDE

Wall-mount option (/B)

B

▲ ▲

A

E

▲ ▲C

D

▲▲

Ceiling mount option (/X)

B

▲ ▲

A

E

▲ ▲C

▲ ▲

A

▲▲▲▲▲▲▲▲▲▲▲▲

▲▲

AC

B

▲ ▲

Pendant pole option (/G)

TECHNICAL DRAWINGS

LED

Lig

htin

g

ALUMINIUM EMERGENCY LED EXIT LIGHTZONES 1 & 2

Page 50: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

48 Hazardous Areas

Catalogue No. Watts Voltage

Dimensions (mm)

Length Width Height Luminous fl ux (lm) Input Current (mA) Weight (kg)

LEDA120SPT/Z1 120 AC180-277 426 410 187 9800 – 11500 400 13.5

LEDA150SPT/Z1 150 AC180-277 426 410 187 12000 – 14400 510 13.5

Product Description Catalogue No.

Bracket For ceiling mounting BR-F-O

Stanchion Bracket

SBT-F-O

SBT2-F-O

SBT-F-O

Eyebolt For pendant mounting LO-F

Pipe Connector PCR-F

Guards GU-F

Range:Frog Series

OVERVIEWThe explosion-proof LED lowbay are an energy saving light designed for use in hazardous and marine locations. The robust construction is designed to operate in salt water and corrosive environments. Suitable for use within chemical, petrochemical, dust and grain applications.

FEATURES• Energy saving• Anti-glare reduces glare where end user has direct visual

contact with the light source• Shock and vibration resistant tempered glass• Optional luminous intensity and colour temps available

MATERIALS• Body – High impact resistant aluminium alloy• Lamps – 150W and 120W options• Lamp source – Osram LED• Surface finish – High corrosion epoxy powdercoated orange

INCLUSIONS• Light• Fixings• Mount supplied seperately

CERTIFICATIONIECEx CQM 13.0003X

PROTECTIONEx d e IIB T6 or T6 GbEx tb IIIC T95ºC or T80ºC Db IP66

AMBIENT TEMPERATURE-40ºC ~ +55ºC

IP66

Guards

Bracket for ceiling mounting

Stanchion bracket

Eyebolt for pendant mounting

Pipe Connector

SELECTION GUIDE

INSTALLATION ACCESSORIES

ALUMINIUM LED LOWBAY LIGHTZONE 1 & 2, 21 & 22

Page 51: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 49

Candela Distribution Beam Angle

Colour Temp

Warm Natural Cool

A 40 1 2 3

B 60 1 2 3

C 80 1 2 3

D 120 1 2 3

E C0-180º:120C90-270º:60 1 2 3

F C0-180º:110C90-270º:120 1 2 3

TECHNICAL DRAWINGS

PART NUMBER ORDER CONVENTION

LEDA120SPT/Z1/ /

Standard catalogue number

Distribution type

Colour temp

Top View Side view

426mm

187m

m

Ø410mm

LIGHT DISTRIBUTION CURVE

9800 10080

390 940 530

1170 1880 1060

1950 3760 2120

2730 5640 3180

3120 7520 7520

1400 1200

2800 2520

4200 5010

7000 7560

D

B

E

C

F180 180 180

180 180

170 170 170

170 170

160 160 160

160 160

150 150 150

150 150

140 140 140

140 140

130 130 130

130 130

120 120 120

120 120

110 110 110

110 110

100 100 100

100 100

90 90 90

90 90

80 80 80

80 80

70 70 70

70 70

60 60 60

60 60

50 50 50

50 50

40 40 40

40 40

30 30 30

30 30

30 30 30

30 30

40 40 40

40 40

50 50 50

50 50

60 60 60

60 60

70 70 70

70 70

80 80 80

80 80

90 90 90

90 90

100 100 100

100 100

110 110 110

110 110

120 120 120

120 120

130 130 130

130 130

140 140 140

140 140

150 150 150

150 150

160 160 160

160 160

170 170 170

170 170

20 20 20

20 20

20 20 20

20 20

10 10 10

10 10

10 10 10

10 1049220

12480

18720

24960

37440

A 180 170 160150

140130

120110100

90

80

70

6050

403030

4050

6070

8090

100

110120

130140

150160 170

2020 1010 0

0 0 0

0 0

LED

Lig

htin

g

ALUMINIUM LED LOWBAYZONE 1 & 2, 21 & 22

Page 52: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

50 Hazardous Areas

Catalogue No. Watts

Dimensions (mm)

Length Width Height Luminous fl ux (lm) Input Current (mA) Weight (kg)

LEDA18BAR/Z1* 18 480 180 62 1500 – 1800 300 4.7

LEDA30BAR/Z1* 30 480 180 62 2500 – 3000 600 4.7

* For more information on candela distribution please see page 51.

Bracket for ceiling mounting

Pipe Clamp

Wire GuardEyebolt for pendant mounting

Product Description Catalogue No.

Bracket For ceiling mounting BR-A-O

Pipe Clamp PCP-A

Eyebolt For pendant mounting LO-A

Guard GU-A

Range:Arowana Series

FEATURES• Energy saving• Anti-glare reduces glare where end user has direct visual

contact with the light source• Shock and vibration resistant tempered glass• Optional luminous intensity and colour temps available

MATERIALS• Body – High impact resistant aluminium alloy• Lamps – 18W and 30W options• Lamp source – Osram LED• Rated voltage 100 - 240V• Surface finish – High corrosion epoxy powdercoated orange

INCLUSIONS• Light• Long-life energy saving LED• Fixings

CERTIFICATIONIECEx CQM 12.0034X

PROTECTIONEx d IIB T6 GbEx tb IIIC T80ºC Db IP66

AMBIENT TEMPERATURE-40ºC ~ +55ºC

IP66

SELECTION GUIDE

INSTALLATION ACCESSORIES

OVERVIEWThe explosion-proof LED linear lights are an energy saving light designed for use in hazardous and marine locations. The robust construction is designed to operate in salt water and corrosive environments. Suitable for use within chemical, petrochemical, dust and grain applications.

ALUMINIUM LED LINEAR LIGHTZONES 1 & 2, 21 & 22

Page 53: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 51

TECHNICAL DRAWINGS

Front View Side View

Colour Temp *

Warm White 1

Natural White 2

Cool White 3

* References catalogue numbers on page 50.

PART NUMBER ORDER CONVENTION

LEDA18BAR/Z1/

Standard catalogue number

Colour temp (eg. 1, 2 or 3)

480mm 180mm▲ ▲▲ ▲

62m

m

LIGHT DISTRIBUTION CURVE

610

800

1120

1280

180 170 160150

140130

120110100

90

80

70

6050

403030

4050

6070

8090

100

110120

130140

150160 170

2020 1010 0

LED

Lig

htin

g

ALUMINIUM LED LINEAR LIGHTZONES 1 & 2, 21 & 22

Page 54: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

52 Hazardous Areas

Catalogue No. Watts

Dimensions (mm)

Length Width Height Luminous fl ux (lm) Input Current (mA) Weight (kg)

LEDA30SPT/Z1 30 311 300 190 2400 – 2900 310 5.3

LEDA60SPT/Z1 60 311 300 190 4100 – 2900 600 5.5

Product Description Catalogue No.

Brackets For ceiling mounting BR-A-O

Stanchion bracket SBT-GF-O

Eyebolt For pendant mounting LO-A

Pipe clamp PCP-A

Guard GU-GF

FEATURES• Energy saving• Anti-glare reduces glare where end user has direct visual

contact with the light source• Shock and vibration resistant tempered glass• Optional luminous intensity and colour temps available

MATERIALS• Body – High impact resistant aluminium alloy• Lamps – 30W and 60W options• Lamp source – Osram LED• Rated voltage 100 - 240V• Surface finish – High corrosion epoxy powdercoated orange

INCLUSIONS• Light• Long-life energy saving LED• Fixings• Mount supplied seperately

CERTIFICATIONIECEx CQM 12.0033 x

PROTECTIONEx d IIB T5/T6 GbEx t IIIC T95ºC/T80ºC Db IP66

AMBIENT TEMPERATURE-40ºC ~ +55ºC

Range:Goldenfrog

IP66

SELECTION GUIDE

INSTALLATION ACCESSORIES

OVERVIEWThe explosion-proof LED lowbay are an energy saving light designed for use in hazardous and marine locations. The robust construction is designed to operate in salt water and corrosive environments. Suitable for use within chemical, petrochemical, dust and grain applications.

Guards

Bracket for ceiling mounting

Eyebolt for pendant mounting

Pipe Clamp

ALUMINIUM LED LOWBAYZONES 1 & 2, 21 & 22

Page 55: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 53

LIGHT DISTRIBUTION CURVES

Catalogue No. Candela Distribution

Colour Temp

Warm Natural Cool

LEDA30SPT/Z1

A 1 2 3

B 1 2 3

C 1 2 3

D 1 2 3

E 1 2 3

F 1 2 3

LEDA60SPT/Z1

A 1 2 3

B 1 2 3

C 1 2 3

D 1 2 3

E 1 2 3

F 1 2 3

PART NUMBER ORDER CONVENTION

LEDA30SPT/Z1/ /

Standard catalogue number

Distribution type

Colour temp

D

B

E

C

F

A

70

140

280

350

420

180 170 160150

140130

120110100

90

80

70

6050

403030

4050

6070

8090

100

110120

130140

150160 170

2020 1010 0

70

140

280

350

420

180 170 160150

140130

120110100

90

80

70

6050

403030

4050

6070

8090

100

110120

130140

150160 170

2020 1010 0

360

420

480

640

700

180 170 160150

140130

120110100

90

80

70

6050

403030

4050

6070

8090

100

110120

130140

150160 170

2020 1010 0

360

420

480

640

700

180 170 160150

140130

120110100

90

80

70

6050

403030

4050

6070

8090

100

110120

130140

150160 170

2020 1010 0

4000

8000

12000

16000

20000

180 170 160150

140130

120110100

90

80

70

6050

403030

4050

6070

8090

100

110120

130140

150160 170

2020 1010 0

4000

8000

12000

16000

20000

180 170 160150

140130

120110100

90

80

70

6050

403030

4050

6070

8090

100

110120

130140

150160 170

2020 1010 0LE

D L

ight

ing

TECHNICAL DRAWINGS

Top View Side View

311m

m

190m

m

ALUMINIUM LED LOWBAYZONES 1 & 2, 21 & 22

Page 56: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

54 Hazardous Areas

Catalogue No. Watts

Dimensions (mm)

Length Width Height Mounting Weight (kg)

LED030FLD/C/Z1 30 280 220 156

Bracket

5.4

LED045FLD/C/Z1 45 290 240 160 5.55

LED060FLD/C/Z1 60 290 240 160 5.55

LED030FLD/P9/Z1 30 280 220 156

90º Pole

5.4

LED045FLD/P9/Z1 45 290 240 160 5.55

LED060FLD/P9/Z1 60 290 240 160 5.55

LED030FLD/P2/Z1 30 280 220 156

25º Pole

5.4

LED045FLD/P2/Z1 45 290 240 160 5.55

LED060FLD/P2/Z1 60 290 240 160 5.55

LED030FLD/W/Z1 30 280 220 156

Wall

5.4

LED045FLD/W/Z1 45 290 240 160 5.55

LED060FLD/W/Z1 60 290 240 160 5.55

ALUMINIUM LED LOWBAYZONES 1 & 2, 21 & 22

FEATURES• Energy saving and long service life LED lamps• Service life up to 50,000 hours• Convenient mounting and ease of maintenance• Multiple mounting options available

MATERIALS• Body – Aluminium alloy• Transparent cover – Toughened glass• Lamp source – Osram LED• Surface finish – Epoxy powdercoated grey

INCLUSIONS• Phoenix cage terminals• Voltage range of AC 100 – 240V• Lamp options – 30W, 45W and 60W

CERTIFICATIONIECEx CQM 13.0025x

PROTECTIONEx de IICDIP A21 TA

For 'T Rating' refer to IECEx certificate

AMBIENT TEMPERATURE-40ºC Ta +50ºC

Range:CZ0873/1 (30W)CZ0874/1 (45W / 60W)

IP66

SELECTION GUIDE

Catalogue No.

Product To suit 30W To suit 45W & 60W

Ceiling bracket (set) D8722/1 D8722/1

Mounting bracket (set) D8701/1 D8701/2

Pendant mounting bracket (set) D8702/1 D8702/2

¾" straight pipe (set) D732

Chain (set) D623

Lamp pole – fence (set) D8725

Lamp pole – flange (set) D8726

INSTALLATION ACCESSORIES

Bracket mount Pole 90º

Wall mountPole 25º

OVERVIEWThe explosion-proof LED lowbay are an energy saving light designed for use in hazardous and marine locations. The robust construction is designed to operate in salt water and corrosive environments. Suitable for use within chemical, petrochemical, dust and grain applications.

Page 57: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 55

ALUMINIUM LED LOWBAYZONES 1 & 2, 21 & 22

TECHNICAL DRAWINGS

LIGHT DISTRIBUTION CURVE

30W

Side View

Front View – mounting bracket

Side Vew – pole mount 90º Side Vew – pole mount 25º

Front View – bracket mount Front View – pendant mount

45W 60W

0

120

240

360

480

600

720

-90

-60

-30 0 30

0

200

400

600

800

1000

1200

-90

-60

-30 0 30

0

200

400

600

800

1000

1200

-90

-60

-30 0 30

A

▲ ▲B

LED

Lig

htin

g

Page 58: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

56 Hazardous Areas

ALUMINIUM LED WELL GLASSZONES 1 & 2, 21 & 22

Catalogue No. Watts

Dimensions (mm)

Height Width Mounting Weight (kg)

LEDA020FLD/C/Z1 20W 208 241

Ceiling

4.05

LEDA030FLD/C/Z1 30W 208 241 4.05

LEDA050FLD/C/Z1 50W 350 255 7.40

LEDA070FLD/C/Z1 70W 350 255 7.40

LEDA100FLD/C/Z1 100W 385 295 8.40

LEDA120FLD/C/Z1 120W 385 295 8.40

LEDA020FLD/H/Z1 20W 208 241

Hook

3.64

LEDA030FLD/H/Z1 30W 208 241 3.64

LEDA050FLD/H/Z1 50W 350 255 6.50

LEDA070FLD/H/Z1 70W 350 255 6.50

LEDA100FLD/H/Z1 100W 385 295 7.50

LEDA120FLD/H/Z1 120W 385 295 7.50

LEDA020FLD/P/Z1 20W 208 241

Pendant pole

4.45

LEDA030FLD/P/Z1 30W 208 241 4.45

LEDA050FLD/P/Z1 50W 350 255 7.80

LEDA070FLD/P/Z1 70W 350 255 7.80

LEDA100FLD/P/Z1 100W 385 295 8.80

LEDA120FLD/P/Z1 120W 385 295 8.80

LEDA020FLD/W/Z1 20W 208 241

Wall

4.42

LEDA030FLD/W/Z1 30W 208 241 4.42

LEDA050FLD/W/Z1 50W 350 255 9.20

LEDA070FLD/W/Z1 70W 350 255 9.20

LEDA100FLD/W/Z1 100W 385 295 10.20

LEDA120FLD/W/Z1 120W 385 295 10.20

LEDA020FLD/S/Z1 20W 208 241

Pole

3.25

LEDA030FLD/S/Z1 30W 208 241 3.25

LEDA050FLD/S/Z1 50W 350 255 7.70

LEDA070FLD/S/Z1 70W 350 255 7.70

LEDA100FLD/S/Z1 100W 385 295 8.70

LEDA120FLD/S/Z1 120W 385 295 8.70

FEATURES• Energy saving and long service life LED lamps• Isolated LED lamp compartment• Wind convection heat dissipation structure• Three enclosure sizes

MATERIALS• Body – Copper-free aluminium alloy• Transparent cover – Toughened glass• Lamp source – Long-life LED• Rated voltage – AC 187–265V, 50/60Hz• Surface finish – Epoxy powdercoated yellow

INCLUSIONS• Lamp options – 20W, 30W, 50W, 70W, 100W and 120W• Multiple mounting options

CERTIFICATIONIECEx CQM 12.0009x

PROTECTIONEx d IIC T6 (-40ºC≤Ta≤+40ºC) / T5 (-40ºC≤Ta≤+55ºC) GbEx t IIIC T80ºC (-40ºC≤Ta≤+40ºC) /T95ºC (-40ºC≤Ta≤+55ºC) Db IP66

AMBIENT TEMPERATURE-40ºC ~ +55ºC T5-40ºC ~ +40ºC T6 Range:

BAD85 Series

IP66/67

SELECTION GUIDE

OVERVIEWThe explosion-proof LED well glass lights are an energy saving light designed for use in hazardous and marine locations. The robust construction is designed to operate in salt water and corrosive environments. Suitable for use within chemical, petrochemical, dust and grain applications.

Page 59: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 57

ALUMINIUM LED WELL GLASSZONES 1 & 2, 21 & 22

TECHNICAL DRAWINGS

LIGHT DISTRIBUTION CURVE

20W & 30W 50W & 70W 100W & 120W

Front View – 20W &30W Front View – 50W &70W Front View – 100W &120W

▲ ▲

▲ ▲ ▲

208m

m

350m

m

385m

m

▲ ▲ ▲▲ ▲ ▲210mm 255m 295mm

0 0 0

160 60 40

320 12080

480 180120

640 240160

800 300200

0º 0º 0º30º 30º 30º

60º60º 60º

90º 90º 90º

LED

Lig

htin

g

Page 60: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

58 Hazardous Areas

OVERVIEWThe 400W flameproof well glass light fittings are manufactured from aluminium with a toughened glass diffuser. They are suitable for use in chemical and petrochemical applications.

FEATURES• Integral control gear• Stainless steel fixings• Multiple mounting methods

MATERIALS• Body – Aluminium alloy• Diffuser – Toughened glass• Lamp sources

High Pressure Sodium, Metal Halide or Mercury Vapour• Lamp holder – E40• Rated voltage – AC 240V, 50Hz • Ballast – Conventional• Wire guard – Zinc coated• Surface finish – Epoxy powdercoated yellow or grey

INCLUSIONS• Stainless steel fixings• Integral control gear• Wire guard• Optional external dome or angle reflector available

CERTIFICATIONIECEx CQM 12.0028

PROTECTIONEx d IIC T3

AMBIENT TEMPERATURE-20ºC ~ +55ºC

ALUMINIUM WELL GLASS LIGHT 400WZONES 1 & 2

Catalogue No.

Dimensions (mm)

Length Height Total Height Lamp Source Mounting Weight (kg)

WGA400MH/H 308 648 798

Metal Halide (MH)

Hook 20.85

WGA400MH/P 308 648 1088 Pendant 23.65

WGA400MH/B 308 648 635 Wall 23.25

WGA400MH/C 308 643 643 Ceiling 21.50

WGA400MH/S 480 595 3000 Stanchion / Pole 21.80

WGA400MV/H 308 648 798

Mercury Vapour (MV)

Hook 20.85

WGA400MV/P 308 648 1088 Pendant 23.65

WGA400MV/B 308 648 635 Wall 23.25

WGA400MV/C 308 643 643 Ceiling 21.50

WGA400MV/S 480 595 3000 Stanchion / Pole 21.80

WGA400HS/H 308 648 798

High Pressure Sodium (HS)

Hook 20.85

WGA400HS/P 308 648 1088 Pendant 23.65

WGA400HS/B 308 648 635 Wall 23.25

WGA400HS/C 308 643 643 Ceiling 21.50

WGA400HS/S 480 595 3000 Stanchion / Pole 21.80

IP66

Product Description Catalogue No.

External ReflectorsAngle RA400

Dome RD400

SELECTION GUIDE

External Refl ector – angled

External Refl ector – dome

INSTALLATION ACCESSORIES

Page 61: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 59

ALUMINIUM WELL GLASS LIGHT 400WZONES 1 & 2

Mounting Options

Front View Front View with Dome Reflector

Front View with Angled Reflector

308▲ ▲

648

130

152

▲ ▲

▲▲

Ø 469▲ ▲

185

70

Ø 466

P: Pendant Mount

440

648

308▲ ▲

H: Hook Mount

648

150

308▲ ▲

B: Wall Mount

615▲ ▲

635

30º

C: Ceiling Mount

308▲ ▲

643

S: Pole Mount

▲▲

▲ 3000

595

480

▲Ø 50

TECHNICAL DRAWINGS

TECHNICAL DRAWINGS

60140220300380460520

120

90

60

180 150

30

60140220300380460520

90

60

180 150 120

30

60140220300380460520600680

90

60

180 150 120

30

Luminous intensity distribution = cd/1000lmBased on 400W metal halide lampfor High Pressure Sodium multiply x 1.37for Mercury lamp multiply x 0.6

Wel

l Gla

ssLi

ghtin

g

Page 62: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

60 Hazardous Areas

Catalogue No.

Dimensions (mm)

WattsWidth

(A)Depth

(B)Height

(C)Total Height

(D) Lamp Source Weight (kg)

WGA175MH/T 175 286 276 465 587

Metal Halide

14.45

WGA250MH/T 250 286 276 465 587 14.45

WGA400MH/T 400 324 317 532 660 20.0

WGA175MV/T 175 286 276 465 587

Mercury Vapour

14.45

WGA250MV/T 250 286 276 465 587 14.45

WGA400MV/T 400 324 317 532 660 20.0

WGA150HS/T 150 286 276 465 587

High Pressure Sodium

14.45

WGA250HS/T 250 286 276 465 587 14.45

WGA400HS/T 400 324 317 532 660 20.0

ALUMINIUM WELL GLASS LIGHTZONES 1 & 2

OVERVIEWThe aluminium flameproof well glass light fittings are manufactured from aluminium with a toughened glassdiffuser. They are suitable for use in chemical and petrochemical applications.

FEATURES• Integral control gear• Stainless steel fixings• Multiple mounting method• Ex d e configuration for ease of termination

MATERIALS• Body – Aluminium alloy• Diffuser – Toughened glass• Lamp sources High Pressure Sodium, Metal Halide or Mercury Vapour• Lamp holder – E40• Rated voltage – AC 240V, 50Hz • Wire guard – Zinc coated• Surface finish – Epoxy powdercoated yellow or grey

INCLUSIONS• Stainless steel fixings• Integral control gear• Optional external dome or angle reflector available

CERTIFICATIONECEx CQM 12.0029 (150W – 250W)IECEx CQM 12.0031x (400W only)

PROTECTIONEx d e IIC T3 (150W – 250W)Ex d e IIC T3 Gb (400W only

AMBIENT TEMPERATURE-20ºC ~ +55ºC (150W – 250W)-20ºCTa+55ºC (400W only IP

65

SELECTION GUIDE

Product Description Catalogue No.

External Reflectors – angled

To suit 400W light RA400/T

To suit 250W light RA250/T

To suit 175W light RA175/T

External reflectors – dome

To suit 400W light RD400/T

To suit 250W light RD250/T

To suit 175W light RD175/T

External Refl ector – angled

External Refl ector – dome

INSTALLATION ACCESSORIES

Page 63: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 61

ALUMINIUM WELL GLASS LIGHTZONES 1 & 2

▲ ▲

D C

▲ ▲

A

Front View

▲ ▲

B

Side View

▲▲ ▲▲ ▲

▲▲

E

20

Front ViewDome Reflector

Mounting BracketSide ViewAngled Reflector

15º

▲13

TECHNICAL DRAWINGS

LIGHT DISTRIBUTION CURVES

WGA 250 Series (includes 150W, 175W and 250W)

180º

0

40

80

120

160

2000º 30º

50º

90º

150º 180º

0

80

160

240

360

4000º 30º

50º

150º 180º

0

60

120

180

2400º 30º

45º

90º

135º

WGA 400W

180º

0

20

40

60

80

1000º 30º

60º

90º

150º 180º

0

40

80

120

160

0º 30º

50º 50º

90º 90º

150º 180º

0

40

80

120

160

0º 30º

135º

Wel

l Gla

ssLi

ghtin

g

Page 64: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

62 Hazardous Areas

Catalogue No.

Dimensions (mm) Entries^

WattsWidth

(A)Height

(B)Depth

(C) Lamp Source Mounting Number Type Weight (kg)

FLDA175MH/M 175 330 650 195

Metal Hallide(MH)

Portable 1 x M25 Clearance 13.0

FLDA250MH/M 250 330 650 195 Portable 2 x M20 Clearance 13.0

FLDA175MH/T 175 314 621 195 Fixed 1 x M25 Clearance 13.0

FLDA250MH/T 250 314 621 195 Fixed 2 x M20 Clearance 13.0

FLDA400MH/T 400 454 500 335 Fixed 2 x M25 Threaded 28.0

FLDA150HS/M 150 490 195 650

High Pressure Sodium(HS)

Portable 1 x M25 Clearance 13.0

FLDA250HS/M 250 330 195 600 Portable 1 x M25 Clearance 13.0

FLDA150HS/T 150 314 195 621 Fixed 1 x M25 Clearance 13.0

FLDA250HS/T 250 314 195 571 Fixed 1 x M25 Clearance 13.0

FLDA400HS/T 400 454 335 500 Fixed 2 x M25 Threaded 28.0

Please Note: 175W option not available with High Pressure Sodium lamp source^ All entries are 2 entries, 1 plugged

ALUMINIUM 150W-400W FLOODLIGHTZONES 1 & 2

OVERVIEWSuitable for use in Zone 1 & 2 applications, the robust construction allows the fixture to be utilised in the most arduous of environments.

Available in fixed or portable mounting.

FEATURES• Seperate Ex e rated termination compartment• Portable option available with plug and cable fitted on

request up to 20 metres• 150–250W available in either portable or fixed mounting• 400W available in fixed mounting only

MATERIALS• Body – Aluminium alloy• Diffuser – Toughened glass• Lamp sources High Pressure Sodium, Metal Halide or Mercury Vapour• Lamp holder – E40• Rated voltage – AC 240V, 50Hz • Wire guard – Zinc coated• Surface finish – Epoxy powdercoated yellow or grey

INCLUSIONS• Stainless steel fixings• Lamp holder• 150-250W – 2 x M25, 1 plugged clearance hole• 400W – 2 x M20, 1 plugged• 150–250W available in portable or fixed mounting• 400W available in fixed mounting only• Ex e termination box for ease of cabling

CERTIFICATIONECEx CQM 12.0025 (150W – 250W)IECEx CQM 12.0030 (400W only))

PROTECTIONEx de IIB T3 Gb (150W – 250W)Ex de IIB T3 (400W only)

SELECTION GUIDE

IP65

Page 65: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 63

ALUMINIUM 150W-400W FLOODLIGHTZONES 1 & 2

TECHNICAL DRAWINGS

LIGHT DISTRIBUTION CURVE

A: 250 Series – Portable mounting option

B

▲ ▲

490

▲ ▲C

Side ViewFront View

▲ ▲

A

B: 250 Series – Fixed mounting option

B

▲ ▲C

Side View Fixing PointsFront View

▲ ▲A

▲▲40

▲180

310

3 x Ø12

C: 400 Series – Fixed mounting only

Front View Side View Fixing Points

B

▲ ▲

A

▲▲ C

▲▲

Ø165 ▲

4 x Ø13

▲▲40

300

450

150

Floo

dlig

htin

g

Page 66: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

64 Hazardous Areas

Catalogue No. Dimensions (mm)

Metal Hallide High Pressure Sodium High Pressure Mercury Watts Width Height Mounting Type

WGA175/MH/C/Z2 WGA150/HS/C/Z2 – 175W 235 365

CeilingWGA250/MH/C/Z2 WGA250/HS/C/Z2 WGA250/MV/C/Z2 250W 300 435

WGA400/MH/C/Z2 WGA400/HS/C/Z2 WGA400/MV/C/Z2 400W 300 485

WGA175/MH/W/Z2 WGA150/HS/W/Z2 – 150W 345 325

WallWGA250/MH/W/Z2 WGA250/HS/W/Z2 WGA250/MV/W/Z2 250W 470 425

WGA400/MH/W/Z2 WGA400/HS/W/Z2 WGA400/MV/W/Z2 400W 490 465

WGA175/MH/P25/Z2 WGA150/HS/P25/Z2 – 150W 235 365

Pole 25ºWGA250/MH/P25/Z2 WGA250/HS/P25/Z2 WGA250/MV/P25/Z2 250W 300 435

WGA400/MH/P25/Z2 WGA400/HS/P25/Z2 WGA400/MV/P25/Z2 400W 300 485

WGA175/MH/P/Z2 WGA150/HS/P/Z2 – 150W 260 340

Pendant PoleWGA250/MH/P/Z2 WGA250/HS/P/Z2 WGA250/MV/P/Z2 250W 345 410

WGA400/MH/P/Z2 WGA400/HS/P/Z2 WGA400/MV/P/Z2 400W 345 460

ALUMINIUM WELL GLASS FLOODLIGHTZONE 2, 21 & 22

Range:BnD81 Series

OVERVIEWSuitable for use in zone 2 applications and available in two enclosure sizes with various lamp types to suit the application. The explosion proof well glass floodlight has an aluminium body and toughened glass cover to withstand the most challenging conditions.

FEATURES• Integral control gear for easy installation and maintenance• Dome reflector available

SELECTION GUIDE

MATERIALS• Body – Copper-free aluminium alloy• Transparent cover – Toughened glass, stands 4J impact• Fixings – 316 stainless steel• Lamp holder – E27• Surface finish – Powdercoated yellow

INCLUSIONS• 1 x M25 x 1.5mm cable entries• Fixings

CERTIFICATIONIECEx CQM 12.0010x (175W & 250W)IECEx CQM 12.0039x (400W)

PROTECTIONEx nR IIC T3 GcEx t IIIC T190ºC Db IP65

AMBIENT TEMPERATURE-60ºC ~ +55ºC

IP66

Page 67: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 65

ALUMINIUM WELL GLASS FLOODLIGHTZONE 2, 21 & 22

TECHNICAL DRAWINGS

LIGHT DISTRIBUTION CURVE

150W 250W 400W

0

00

1818 16

3636

32

54 54

48

72 72

64

900º

0º 0º30º

30º 30º

60º

60º60º

90º

90º90º

Floo

dlig

htin

g

Hei

ght

Front View – ceiling mount

Width

▲ ▲

Front View – wall mount Front View – pendant pole Front View – 25º pole

Hei

ght

Width

▲ ▲

Hei

ght

Hei

ght

▲ ▲

Width

▲ ▲

Page 68: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

66 Hazardous Areas

Catalogue No.

Dimensions (mm)

Watts Lamp Source Height Width Depth Weight (kg)

FLDA150HS/Z2 150

High Pressure Sodium

418 572 165 12.85

FLDA250HS/Z2 250 418 572 165 12.85

FLDA400HS/Z2 400 418 572 165 12.85

FLDA150MH/Z2 150

Metal Hallide

418 572 165 12.85

FLDA250MH/Z2 250 418 572 165 12.85

FLDA400MH/Z2 400 418 572 165 12.85

ALUMINIUM FLOODLIGHTZONE 1 & 2, 21 & 22

Range:BnT81 Series

FEATURES• Rapid starting and stable performance• All exposed fasteners are stainless steel

SELECTION GUIDE

MATERIALS• Body – Copper-free aluminium alloy• Cover – Toughened glass, stands 4J impact• Internal reflector – High purity aluminium• Fixings – 316 stainless steel• Lamp – 400W• Lamp holder – E40• Surface finish – Powdercoated white

INCLUSIONS• Fixings

CERTIFICATIONIECEx CQM 12.0011x

PROTECTIONEx nR IIC T3 GcEx nR IIC T252º GcEx t IIC T190ºC Db IP65Ex t IIIC T252ºC Db IP65

AMBIENT TEMPERATURE-60ºC ~ +55ºC

IP66

TECHNICAL DRAWINGS

OVERVIEWSuitable for use in zone 2 applications and available in two enclosure sizes with various lamp types to suit the application. The explosion proof floodlight has an aluminium body and toughened glass cover to withstand the most challenging conditions..

Front View Side View

572mm▲ ▲ 165mm▲ ▲

418m

m

Page 69: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 67

Catalogue No.

Dimensions (mm)

Watts Width Height Lamp Source Mounting Type

WGV035TH/A 35 126 204Halogen Tungsten

Arm

WGV035TH/B 35 126 204 Ceiling

ALUMINIUM TANK INSPECTION VESSEL LIGHTZONES 1 & 2

IP65

OVERVIEWThe flameproof tank inspection vessel light fittings are manufactured from aluminim alloy with a toughened glass diffuser and are suitable for use in chemical and petrochemical applications.

FEATURES• Specially designed reflector

MATERIALS• Body – Aluminium alloy• Diffuser – Toughened glass• Lamp sources – Halogen Tungsten• Lamp wattage – 35W• Rated voltage – 240V, 50Hz• Surface finish – Epoxy powdercoated yellow

INCLUSIONS• Mounting arm or ceiling bracket• 1 x M20, cable gland entries

CERTIFICATIONIECEx LCI 08.0007

PROTECTIONEx d IIB T3 IP65

AMBIENT TEMPERATURE-20ºC ~ +55ºC

SELECTION GUIDE

Range:BAK51 Series

TECHNICAL DRAWINGS

Side View Mounting Option (/A) Front View Mounting Option (/B)

204m

m

205.

5mm

▲ ▲

▲ ▲

126mm166.5mm▲

▲▲

Floo

dlig

htin

g

Page 70: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

68 Hazardous Areas

Catalogue No.

Dimensions (mm)

Lamp Length Width Height Weight (kg)

FLDS300TH/T/Z2 300W 337 137 360 5.3

300W HALOGEN FLOODLIGHTZONE 2

Range:PF-HnR Series

IP66/67

OVERVIEWThe 300W halogen floodlight is manufactured from 316 stainless steel with heat and impact resistant glass front. The powdercoated stainless steel construction and IP66/67 protection rating allows it to be used in the most arduous environments.

FEATURES• 316 stainless steel construction• Stainless steel trunnion mounting arm• Vertical adjustment (up 75º, down 45º)

SELECTION GUIDE

MATERIALS• Body – 316 stainless steel, deep drawn• Glass front – Heat and impact resistant• Gasket – Silicone rubber• Internal reflector – High reflectance aluminium• Fixings – 316 stainless steel• Lamp holder – R7S• Rated voltage – 240V, 50Hz• Surface finish – Epoxy powdercoated white

INCLUSIONS• 300W Halogen lamp• 1 x M20 cable gland entry• Stainless steel trunnion mounting arm• Rubber mount pad for high vibration areas

CERTIFICATIONIECEx KGS 07.0005x

PROTECTIONEx n R II T2 IP67

AMBIENT TEMPERATURE-20ºC ~ +55ºC

Range:PF-HnR

Page 71: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 69

300W HALOGEN FLOODLIGHTZONE 2

TECHNICAL DRAWINGS

LIGHT DISTRIBUTION CURVE

Front View Side View Fixing Dimensions

95

2 x ø14 holes

360m

m

337mm

360m

m

▲ ▲ 137mm

M20 cable gland entry

▲ ▲

90º

120º

60º

30º

90º

120º

60º

30º

180

270

360

90

90

Floo

dlig

htin

g

Page 72: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

70 Hazardous Areas

Catalogue No.

Dimensions (mm)

Watts Width Height Mounting Lamp Colour Weight (kg)

LEDA2AVCL/C/Z1/R 2W 195 205

Ceiling

Red 3.0

LEDA2AVCL/C/Z1/B 2W 195 205 Blue 3.0

LEDA2AVCL/C/Z1/Y 2W 195 205 Yellow 3.0

LEDA2AVCL/C/Z1/G 2W 195 205 Green 3.0

LEDA2AVCL/H/Z1/R 2W 195 205

Horizontal

Red 4.45

LEDA2AVCL/H/Z1/B 2W 195 205 Blue 4.45

LEDA2AVCL/H/Z1/Y 2W 195 205 Yellow 4.45

LEDA2AVCL/H/Z1/G 2W 195 205 Green 4.45

ALUMINIUM AUDIO & VISUAL CAUTION LIGHTZONES 1 & 2

FEATURES• Energy saving• Ultra bright LED lamp• Low power consumption and long service life up to

30,000 hours• Pendant and horizontal mounting options

MATERIALS• Body – Copper-free aluminium alloy• Transparent cover – Toughened glass, impact resistant• Lamps – 2W LED• Rated voltage – AC 220-240V, 50/60Hz• Surface finish – Epoxy powdercoated yellow / grey

INCLUSIONS• Lamp colour – Red, blue, yellow and green• Mounting accessories• Flash frequency – 150 times per minute• Sound intensity – 100-200dB• Pendant type supplied with explosion-proof junction box• Horizontal type – 1 x M25 entries• Pendant type – 2 x M25 entries

CERTIFICATIONIECEx CQM 11.0023

PROTECTIONEx d ib IIC T6 Gb

AMBIENT TEMPERATURE-20ºC ~ +55ºC

OVERVIEWThe explosion proof caution lights are an energy saving light designed for use in chemical, petrochemical, grain, dust and other hazardous area applications.

Range:BBJ Series

IP65

SELECTION GUIDE

TECHNICAL DRAWINGS

205m

m

▲ ▲195mm

Page 73: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 71

TECHNICAL DRAWINGS

ALUMINIUM VISUAL CAUTION LIGHTZONES 1 & 2, 21 & 22

FEATURES• Energy saving• Ultra bright LED lamp• Low power consumption and long service life• Pendant and horizontal mounting options

MATERIALS• Body – Copper-free aluminium alloy• Transparent cover – Toughened glass, impact resistant• Lamps – 3W LED• Lamp colour – Red, blue, yellow and green• Rated voltage – AC 220-240V, 50/60Hz• Surface finish – Epoxy powdercoated yellow / grey

INCLUSIONS• Lamp colour – Red, blue, yellow and green• Mounting accessories• Flash frequency – 150 times per minute• Pendant type supplied with explosion-proof junction box• Horizontal type – 1 x M25 entries• Pendant type – 2 x M25 entries

CERTIFICATIONIECEx CQM 12.0038x

PROTECTIONEx d IIC T6 GbEx t IIIC T80ºC Db IP66

AMBIENT TEMPERATURE-40ºC ~ +55ºC

OVERVIEWThe explosion proof caution lights are an energy saving light designed for use in chemical, petrochemical, grain, dust and other hazardous area applications.

Range:BJD81 Series

IP66/67

Catalogue No.

Dimensions (mm)

Width Height Mounting Lamp Colour Weight (kg)

LEDA03VCL/C/Z1/R 146 230

Ceiling

Red 2.5

LEDA03VCL/C/Z1/B 146 230 Blue 2.5

LEDA03VCL/C/Z1/Y 146 230 Yellow 2.5

LEDA03VCL/C/Z1/G 146 230 Green 2.5

LEDA03VCL/H/Z1/R 146 230

Horizontal

Red 4.4

LEDA03VCL/H/Z1/B 146 230 Blue 4.4

LEDA03VCL/H/Z1/Y 146 230 Yellow 4.4

LEDA03VCL/H/Z1/G 146 230 Green 4.4

SELECTION GUIDE

230m

m

▲ ▲146mm

Cau

tion

Ligh

ting

Page 74: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

72 Hazardous Areas

ALUMINIUM LOCAL VISUAL CAUTION LIGHTZONES 1 & 2, 21 & 22

Catalogue No.

Dimensions (mm)

Watts Width Height Mounting Weight (kg)

LEDA10VCL/C/Z1 10W 250 370 Ceiling 10.0

FEATURES• Energy saving• Ultra bright LED lamp• Low power consumption and long service life up to

55,000 hours• Integrated control chip with various circuit protection• Synchronis function of light fitting via signal lines

MATERIALS• Body – Copper-free aluminium alloy• Transparent cover – Toughened glass, impact resistant• Lamps – ≤10W LED• Rated voltage – AC 220-240V, 50/60Hz• Surface finish – Epoxy powdercoated yellow / grey

INCLUSIONS• Lamp colour – Red• Luminous intensity >200cd• Flash frequency – 1 second• 4 x M25 cable entries (3 plugged)

CERTIFICATIONIECEx CQM 11.0026x

PROTECTIONEx de IIC T6 GbEx tb IIIC T80ºC Db IP66

AMBIENT TEMPERATURE-20ºC ~ +55ºC

OVERVIEWThe explosion proof caution lights are an energy saving light designed for use in chemical, petrochemical, grain, dust and other hazardous area applications.

SELECTION GUIDE

Range:BSZD81 Series

IP65

TECHNICAL DRAWINGS

L

Lamp 1

1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6

Lamp 2 Lamp 3

NPEPower Supply220-240V AC 50/60Hz▲

370m

m

▲ ▲250mm

Page 75: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 73

TECHNICAL DRAWINGS

Catalogue No.

Dimensions (mm)

Watts Width Height Mounting Weight (kg)

LEDA40VCL/C/Z1 40 308 420 Ceiling 13.8

FEATURES• Energy saving• Ultra bright LED lamp• Low power consumption and long service life up to

30,000 hours• Integrated control chip with various circuit protection• Synchronis function of light fittings via signal lines

MATERIALS• Body – Copper-free aluminium alloy• Transparent cover – Toughened glass, impact resistant• Lamps – 40W LED• Rated voltage – AC 220-240V, 50/60Hz• Surface finish – Epoxy powdercoated yellow / grey

INCLUSIONS• Lamp colour – Red• Luminous intensity >2000cd• Flash frequency 20-60 times per minute• 4 x M25 entries (3 plugged)

CERTIFICATIONIECEx CQM 11.0026x

PROTECTIONEx de IIC T6 GbEx tb IIIC T80ºC Db IP66

AMBIENT TEMPERATURE-40ºC ~ +55ºC

OVERVIEWThe explosion proof caution lights are an energy saving light designed for use in chemical, petrochemical, grain, dust and other hazardous area applications.

SELECTION GUIDE

Range:BSZD81-C Series

IP65

L

Lamp 1

1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6

Lamp 2 Lamp 3

NPEPower Supply220-240V AC 50/60Hz▲

420m

m

▲ ▲308mm

Cau

tion

Ligh

ting

ALUMINIUM LOCAL VISUAL CAUTION LIGHTZONES 1 & 2, 21 & 22

Page 76: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

74 Hazardous Areas

Catalogue No.

Dimensions (mm)

Watts No. of Lamps Length Width Height Diameter Weight (kg)

FLUA21X1/C 21W 1 270 245 160 160 5.6

FLUA21X2/C 21W 2 270 245 160 160 5.6

IP65

ALUMINIUM ANNULAR COMPACT FLUORESCENTZONES 1 & 2

OVERVIEWThe flameproof annular fluorescent light fittings are manufactured from aluminium alloy and are suitable for use in chemical and petrochemical applications.

FEATURES• Toughened glass cover, anti-impact and high light

transmission• PL compact lamps

MATERIALS• Body – Aluminium alloy• Wire guard – Zinc coated white• Diffuser – High impact glass• Reflector – Pure aluminium• Ballast – Conventional• Lamp holder – GR-10q• Rated voltage – AC240V, 50Hz• Surface finish – Powdercoated yellow or grey

INCLUSIONS• Light fitting• 2 x M20 cable gland entries (1 plugged)• Zinc coated wire guard• Lamps – single or twin 21W supplied

CERTIFICATIONIECEx CQM 12.0027

PROTECTIONEx d IIB T5

AMBIENT TEMPERATURE-20ºC Tamb +55ºC

SELECTION GUIDE

Page 77: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 75

ALUMINIUM ANNULAR COMPACT FLUORESCENTZONES 1 & 2

TECHNICAL DRAWINGS

Top View

245mm

▲ ▲

Front View

21W x 2

270mm

▲ ▲

160m

m

D

4xø10

LIGHT DISTRIBUTION CURVE

0 0

0º 0º30º 30º

60º 60º

90º 90º

40 28

8056

120

84

160

112

140

21W x 1 21W x 2

Flur

oesc

ent

Ligh

ting

Page 78: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

76 Hazardous Areas

Catalogue No.

Dimensions (mm)

Watts No. of LampsLength

(A)Width

(B)Height

(C)Fixings

(D) Weight (kg)

FLUA018X1/C 18W 1 780 181 186 565 7.78

FLUA018X2/C 18W 2 780 181 186 565 7.78

FLUA036X1/C 36W 1 1395 181 186 1180 10.60

FLUA036X2/C 36W 2 1395 181 186 1180 10.60

ALUMINIUM FLUORESCENTZONES 1 & 2

OVERVIEWThe flameproof fluorescent light fittings are manufactured from aluminium and are suitable for use in Zone 1 & 2 applications. The aluminium body allows the fixture to be used in the most arduous of environments.

FEATURES• Electronic ballast• Removable chassis for easy lamp replacement• Anti-vibration rubber mounts• Immersible to 1 metre• Emergency option available on request

MATERIALS• Body – Die cast aluminium• Ballast – Electronic• Lamp holder – T8 Bi Pin• Rated voltage – 240V, 50Hz• Surface finish – Epoxy powdercoated yellow or grey

INCLUSIONS• Lamps – Single or twin 18W or 36W lamps• 2 x M20 entries• Anti-vibration rubber mounts

CERTIFICATIONIECEx KGS 07.0002x (20W)IECEx KGS 07.0003x (40W))

PROTECTIONEx d IIC T6 or T5 IP67

AMBIENT TEMPERATURE-20ºC ~ +50ºC

IP66/67

SELECTION GUIDE

Range:FX Series

Page 79: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 77

ALUMINIUM FLUORESCENTZONES 1 & 2

TECHNICAL DRAWINGS

LIGHT DISTRIBUTION CURVE

Front View Top View

A

▲ ▲

B

C

D

90º

120º

60º

30º

90º

120º

60º

30º

80

120

160

40

40

▲▲▲

Flur

oesc

ent

Ligh

ting

Page 80: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

78 Hazardous Areas

Catalogue No.

Dimensions (mm)

Watts No. of LampsLength

(A)Width

(B)Height

(C) Weight (kg)

FLUS018X2/C 18W 2 706 220 135 4.95

FLUS036X2/C 36W 2 1312 220 135 8.23

STAINLESS STEEL FLUORESCENTZONES 1 & 2

OVERVIEWSuitable for Zone 1 & 2 applications. The stainless steel body allows the fixture to be utilised in the most arduous environments including metalliferous mining, chemical, petrochemical and industrial construction sites.

FEATURES• 316 stainless steel body and fixings• Centre allen key locking arrangement• 2 x M20 entries• Emergency option available on request

MATERIALS• Body – 316 stainless steel• Diffuser – Polycarbonate• Latch & fixings – 316 stainless steel• Lamps – 2 x 18W or 36W• Lamp holder – T8 Bi Pin• Body surface finish – Epoxy powdercoated white

INCLUSIONS• Lamps• Stainless steel retaining clips and mounting feet

CERTIFICATIONIECEx KGS 08.0001x (18W)IECEx KGS 08.0002x (36W))

PROTECTIONEx d emb IIC T4 GbEx d – interlock switch

AMBIENT TEMPERATURE-25ºC ~ +50ºC

SELECTION GUIDE

Range:FL-220EDG (18W)FL-240EDG (36W

IP66/67

Page 81: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 79

STAINLESS STEEL FLUORESCENTZONES 1 & 2

A

▲ ▲

C

B

500mm

▲ ▲ 4 x ø10 holes

188m

m

Front View Top View

90º

120º

60º

30º

90º

120º

60º

30º

70

105

140

35

35

TECHNICAL DRAWINGS

LIGHT DISTRIBUTION CURVE

Flur

oesc

ent

Ligh

ting

Page 82: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

80 Hazardous Areas

Product Catalogue No.

Dimensions (mm)

Watts No. of LampsLength

(A)Width

(B)Height

(C) Mounting Weight (kg)

Standard

FLUG018X1/CA1 18W 1 808 222 134 Ceiling 6.7

FLUG018X2/CA1 18W 2 808 222 134 Ceiling 6.9

FLUG036X1/CA1 36W 1 1380 222 134 Ceiling 11.3

FLUG036X2/CA1 36W 2 1380 222 134 Ceiling 11.4

EmergencyFLUG018X2/CA1E 18W 2 808 222 134 Ceiling 8.7

FLUG036X2/CA1E 36W 2 1380 222 134 Ceiling 13.1

NON-METALLIC FLUORESCENT EMERGENCY & NON-EMERGENCYZONES 1 & 2, 21 & 22

OVERVIEWThe non-metallic fluorescent lights consist of an SMC body with a polycarbonate diffuser. The light fitting is available in both non-emergency and emergency options. The emergency light fitting automatically recharges during normal operations and lamps turn on when there is a power loss

FEATURES• EOL (end of life) on ballast• Key operated central mechanical interlocking device• Ex d switch for automatic power off when cover is unlocked• Fault, charge and discharge signal for emergency models• Internal catches clamp on both sides of diffuser• Installation accessories available

MATERIALS• Body – SMC• Diffuser – Polycarbonate• Terminals – 3 x 1.5 – 4mm• Brass gland plate• Lamps – single or twin 18W or 36W lamp• Lamp holder – T8 Bi Pin• Rated voltage – 250V, 50Hz

INCLUSIONS• Lamps T8 18W or 36W• 2 x M25 entries each end (2 plugged)• Ceiling mount brackets as standard• EOL on ballast

CERTIFICATIONIECEx CQM 12.0026 (standard)IECEx CQM 12.0041 (emergency)

PROTECTIONEx deq IIC T4 GbEx tD A21 IP66 T80ºC

AMBIENT TEMPERATURE-20ºC ≤ Ta ≤ +55ºC

SELECTION GUIDE

IP66

Page 83: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 81

NON-METALLIC FLUORESCENT EMERGENCY & NON-EMERGENCYZONES 1 & 2, 21 & 22

TECHNICAL DRAWINGS

LIGHT DISTRIBUTION CURVE

Front View Top View Side View

A

▲ ▲

C

▲90

▲ B

450mm

▲ ▲

0 0

0º 0º30º 30º

60º 60º

90º 90º

40 40

80 80

120 120

160 160

200 200

18W x 2 36W x 2Fl

uroe

scen

tLi

ghtin

g

Page 84: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

82 Hazardous Areas

Catalogue No.

Dimensions (mm)

Type Watts No. of LampsLength

(A)Width

(B)Height

(C)Fixings

(D) Mounting Weight (kg) Lamp Holder

FLUG014X2/C

Non-emergency

14W 2 725 222 145 400 Ceiling 5.0 T5

FLUG018X2/C 18W 2 725 222 145 400 Ceiling 5.0 T8

FLUG028X2/C 28W 2 1335 222 145 800 Ceiling 7.9 T5

FLUG036X2/C 36W 2 1335 222 145 800 Ceiling 7.9 T8

FLUG014X2/CE

Emergency

14W 2 725 222 145 400 Ceiling 6.8 T5

FLUG018X2/CE 18W 2 725 222 145 400 Ceiling 6.8 T8

FLUG028X2/CE 28W 2 1335 222 145 800 Ceiling 9.9 T5

FLUG036X2/CE 36W 2 1335 222 145 800 Ceiling 9.9 T8

NON-METALLIC FLUORESCENT EMERGENCY & NON-EMERGENCYZONES 1 & 2, 21 & 22

Range:CZ0865/6

OVERVIEWThe non-metallic fluorescent lights consist of an SMC body with a polycarbonate diffuser. The light fitting is available in both non-emergency and emergency options. The emergency light fitting automatically recharges during normal operations and lamps turn on when there is a power loss

FEATURES• EOL (end of life) on ballast• Central mechanical interlocking device• Ex d switch for automatic power off when cover is unlocked• Fault, charge and discharge signal for emergency models• 1 x M25 and 2 x M25 entries at opposite ends• T5 or T8 lamp options• Internal brass plates

MATERIALS• Body – SMC• Diffuser – Polycarbonate• Lamps – 2 x 14W, 18W, 28W and 36W• Lamp holder – T8 for 18W & 36W; T5 for 14W & 28W• Rated voltage – 110-240V

INCLUSIONS• EOL (End of Life) on ballast• Dust cover on key lock• Ceiling mount brackets

CERTIFICATIONIECEx CQM 10.0012

PROTECTIONEx deqmb IIC T4 GbEx tD A21 T80ºC

AMBIENT TEMPERATURE-20ºC ~ +40ºC

SELECTION GUIDE

IP66

Product Size Catalogue No.

Pipe clamps – galvanised steel

42mm – 45mm J200

47mm – 50mm J300

59mm – 62mm J400

INSTALLATION ACCESSORIES

Page 85: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 83

NON-METALLIC FLUORESCENT EMERGENCY & NON-EMERGENCYZONES 1 & 2, 21 & 22

TECHNICAL DRAWINGS

LIGHT DISTRIBUTION CURVE

Front View Side View

A

C

▲ ▲B

▲ ▲

D

▲ ▲

A AB B

315

270

40

90

45

20

40

60

80

100120

160

180

2000

140

2 x 18W 2 x 36W

A AB B

315

270

40

90

45

20

40

60

80

100

120

160

180

2000

140

B 90 B 90

B 90 B 90

A 0 A 0 A 0 A 0

Flur

oesc

ent

Ligh

ting

Page 86: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

84 Hazardous Areas

Catalogue No.

Dimensions (mm)

Watts Lamp TypeLength

(A)Width

(B) Mounting Weight (kg)

LEDA009X1/C/Z1 9W

LED

810 112

Ceiling

5.5

LEDA009X2/C/Z1 9W 810 222 9.8

LEDA018X1/C/Z1 18W 1420 112 6.5

LEDA018X2/C/Z1 18W 1420 222 11.55

FLUA018X1/C/Z1 18W

Fluorescent

1420 112

Ceiling

5.6

FLUA036X1/C/Z1 36W 1535 112 8.8

FLUA058X1/C/Z1 58W 1840 112 10.4

FLUA018X2/C/Z1 18W 1420 222 10.6

FLUA036X2/C/Z1 36W 1535 222 16.3

FLUA058X2/C/Z1 58W 1840 222 18.3

ALUMINIUM FLUORESCENT & LED LIGHTZONES 1 & 2, 21 & 22

FEATURES• End of lamp life rectification effect protection• Single or dual lamp options• Available with fluorescent or LED lamp source options

MATERIALS• Body – Copper-free aluminium alloy• Glass tube – Toughened glass• Ballast – Electronic• Rated voltage – AC 100–300V, 50/60H• Surface finish – Powdercoated yellow

INCLUSIONS• Fluorescent lamp options – single or twin 18W, 36W or 58W• LED lamp options – single or twin 9W and 18W

CERTIFICATIONIECEx CQM 12.0042x (Fluorescent option)IECEx CQM 12.0005 (LED option)

PROTECTIONEx d IIC T6 GbEx t IIIC T80ºC Db IP66

AMBIENT TEMPERATURE-20ºCTa+55ºC (Fluorescent)-40ºC ~ +55ºC (LED)

OVERVIEWSuitable for use in zone 1 & 2 and zone 21 & 22 applications and available in both LED and fluorescent lamp types. The aluminium body and toughened glass diffuser will withstand the most demanding conditions.

SELECTION GUIDE

Range:BAY-51 Series

IP66

Range:

Page 87: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 85

ALUMINIUM FLUORESCENT & LED LIGHTZONES 1 & 2, 21 & 22

TECHNICAL DRAWINGS

LIGHT DISTRIBUTION CURVE

9W x 1

18W x 1

9W x 2

18W x 2

18W x 1

36W x 1 58W x 1

18W x 2

36W x 2 58W x 2

LED Type

Fluorescent Type

A A

B

B

▲ ▲▲ ▲

▲ ▲

Side View – Single lamp Side View – Twin lamp

0

0 0

0 0 0

0 0 0

60

40 40 40 40 40 40

80 80 80 80 80 80

120 120 120 120 120120

160 160 160 160 160160

60 40 40

120 120 80 80

180 180 120 120

240 240 160 160

300 300 200 200

0º 0º 0º 0º 0º 0º

0º 0º 0º30º

30º 30º 30º 30º 30º 30º

30º 30º 30º

60º

60º 60º 60º 60º 60º 60º

60º 60º 60º

90º

90º 90º 90º 90º 90º 90º

90º 90º 90º

Flur

oesc

ent &

LED

Ligh

ting

Page 88: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

86 Hazardous Areas

Catalogue No.

Dimensions (mm)

Type Watts No. of LampsLength

(A)Width

(B)Height

(C)Fixings

(D) Mounting Weight (kg) Lamp Holder

FLUG014X2/C/Z2

Fluorescent

14 2 725 222 145 400

Ceiling

5.0 T5

FLUG018X2/C/Z2 18 2 725 222 145 400 5.0 T8

FLUG028X2/C/Z2 28 2 1335 222 145 800 7.9 T5

FLUG036X2/C/Z2 36 2 1335 222 145 800 7.9 T8

LED010X2/C/Z2LED

10 2 698 222 145 400Ceiling

5.0 T5 Special

LED019X2/C/Z2 19 2 1335 222 145 800 7.9 T8 Special

NON-METALLIC FLUORESCENT & LED EMERGENCY & NON-EMERGENCYZONES 2, 21 & 22

Range:CZ087 Series

OVERVIEWThe polyester central locking fluorescent and LED light fittings are manufactured from glass reinforced polyester and anti-ultraviolet polycarbonate. These light fittings are available with fluorescent or LED lamps. The material provides protection from various chemical matters in factories because of their high stability and mechanical strength and can prevent corrosion from occurring.

FEATURES• Robust construction• Standard ceiling mount• Anti-vibration lamp holders• Mechanical interlocking device• Explosion-proof distance switch for automatic power off• Nicket plated brass and stainless steel cable gland options• Through wiring

MATERIALS• Body – Glass fibre reinforced polyester• Diffuser – Polycarbonate• Fluorescent lamp – twin 14W, 18W, 28W & 36W options• LED lamp – twin 19W standard in 36W body• Lamp holder – T8 or T5, G13• Rated voltage – AC 220-240V, 50/60Hz on request

INCLUSIONS• EOL (End of Life) on ballast• Dust cover on key lock• Ceiling mount brackets• Lamps

CERTIFICATIONIECEx CQM 12.0001

PROTECTIONEx nA IIC T4 Gc/ Ex t IIIC T80ºC Db IP66Ex mb nA IIC T4 Gc/ Ex t IIIC T80ºC Db IP66Ex d nA IIC T4 Gc/ Ex t IIIC T80ºC Db IP66Ex d mb nA IIC T4 Gc/ Ex t IIIC T80ºC Db IP66

AMBIENT TEMPERATURE-25ºC ~ +50ºC

SELECTION GUIDE

IP66

Page 89: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 87

NON-METALLIC FLUORESCENT & LED EMERGENCY & NON-EMERGENCYZONES 2, 21 & 22

TECHNICAL DRAWINGS

LIGHT DISTRIBUTION CURVE

Front View Side View

A

C

▲ ▲B

▲ ▲

D

▲ ▲

Flur

oesc

ent &

LED

Ligh

ting

10W x 2

-90º 90º

-60º

-30º 0º 30º

60º

0

80

160

240

320

400

14W x 2

-90º 90º

-60º

-30º 0º 30º

60º

0

40

80

120

160

200

18W x 2

-90º 90º

-60º

-30º 0º 30º

60º

0

40

80

120

160

200

28W x 2

-90º 90º

-60º

-30º 0º 30º

60º

0

50

100

150

200

250

36W x 2

-90º 90º

-60º

-30º 0º 30º

60º

0

40

80

120

160

200

19W x 2

-90º 90º

-60º

-30º 0º 30º

60º

0

150

300

450

600

750

LED Type

Fluorescent Type

Page 90: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

88 Hazardous Areas

Dimensions (mm)

Catalogue No. Lamp Type Watts No. of LampsLength

(A)Width

(B)Height

(C)Fixings

(D)

FLUP018X1/C/Z2

Fluorescent

18W 1 658 100 101 400

FLUP018X2/C/Z2 18W 2 658 100 101 400

FLUP036X1/C/Z2 36W 1 1268 100 101 900

FLUP036X2/C/Z2 36W 2 1268 100 101 900

FLUP058X1/C/Z2 58W 1 1568 100 101 900

FLUP058X2/C/Z2 58W 2 1568 100 101 900

LEDP009X1/C/Z2

LED

9W 1 658 100 101 400

LEDP009X2/C/Z2 9W 2 658 100 101 400

LEDP018X1/C/Z2 18W 1 1268 100 101 900

LEDP018X2/C/Z2 18W 2 1268 100 101 900

LEDP025X1/C/Z2 25W 1 1568 100 101 900

LEDP025X2/C/Z2 25W 2 1568 100 101 900

NON-METALLIC FLUORESCENT & LED LIGHTZONE 2, 21 & 22

Range:BnY81 Series

FEATURES• Dual tube light available with emergency function• Fluroescent and LED options available• Stainless steel diffuser clips• Internal brass gland plate• Installation accessories available

SELECTION GUIDE

MATERIALS• Body – Polycarbonate• Ballast – Electronic• Exposed fasteners – Stainless steel• Rated voltage – 100 – 300V AC 50/60Hz

INCLUSIONS• Fluorescent lamp options – 1 or 2 18W, 36W or 58W• LED lamp options – 1 or 2 9W and 18W• 2 x M20 x 1.5mm cable glands• Fixings

CERTIFICATIONIECEx CQM 12.0046x

PROTECTIONEx nA IIC T4 GcEx t IIIC T80ºC Db IP66

AMBIENT TEMPERATURE-60ºC ~ +55ºC

IP66

OVERVIEWSuitable for use in zone 2 and zone 21 & 22 applications and available in both LED and fluorescent lamp types. The non metallic polycarbonate body is corrosion proof and impact resistant and the polycarbonate diffuser will withstand the most demanding conditions.

Page 91: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 89

NON-METALLIC & LED FLUORESCENT LIGHTZONE 2, 21 & 22

TECHNICAL DRAWINGS

LIGHT DISTRIBUTION CURVE

A A

C C

▲▲

▲ ▲

▲ ▲▲ ▲

B B

▲▲

Flur

oesc

ent &

LED

Ligh

ting

Front View – Single lamp Front View – Twin lamp

18W x 1

36W x 2

18W x 2

58W x 1

36W x 1

58W x 2

0

0

0

0

0

0

30º

30º

30º

30º

30º

30º

40

40

40

40

40

40

80

80

80

80

80

80

120

120

120

120

120

120

160

160

160

160

160

160

90º

90º

90º

90º

90º

90º

60º

60º

60º

60º

60º

60º

D D

▲ ▲▲ ▲

Page 92: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.
Page 93: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

Plu

g &

So

cket

Ou

tlet

s

Page 94: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

92 Hazardous Areas

IP66

PLUG & SOCKET OUTLETSZONES 1 & 2, 21 & 22

Range:CZ0251 (16Amp)CZ0252 (32Amp)CZ0253 (63Amp)CZ0254 (125Amp)

OVERVIEWDesigned to provide electrical connection within a hazardous area for mobile or portable equipment. Designed with a switch on the inside, the Ex de connection prevents sparking and is high impact resistant.

FEATURES• Internal brass gland plate• Self-cleaning inserting sleeve and contact joints• Protective cover for high degree of protection• Minimal force required when inserting or extracting• Internal switch >32A and external switch for <32A

MATERIALS• Body – SMC anti-static• Surface finish – Textured matt black

OPTIONS• Plug• Socket outlets• Panel socket outlet and coupler socket also available as an option

CERTIFICATIONIECEx CQM 10.0013 (16A)IECEx CQM 09.0009U (32A)IECEx CQM 10.0002 (63A & 125A)IECEx CQM 10.0014U (Panel)

PROTECTIONEx de IIC GbEx tD A21

AMBIENT TEMPERATURE-40ºC ~ +45ºC / 55ºC option

TECHNICAL DRAWINGS

Type

Dimensions (mm) Fixing Dimensions (mm)

Height(A)

Width(B)

Depth(C)

Height(D)

Width(E)

16Amp – 2 Poles 223 103 122 142 86

16Amp – 3 Poles 223 103 122 142 86

16Amp – 4 Poles 241 123 147 163 106

32Amp – 4 Poles 24 133 162 198 118

63Amp – 4 Poles 472 201 248 352 181

125Amp – 4 Poles 537 249 274 411 228

Type Width (mm) Diameter (mm)

16Amp – 2 Poles 163 73

16Amp – 3 Poles 163 73

16Amp – 4 Poles 187 77

16Amp – 5 Poles 187 84

32Amp – 4 Poles 237 96

63Amp – 4 Poles 262 111

125Amp – 4 Poles 298 121

A

D

▲ ▲

▲ ▲

B

Width Diameter

▲ ▲E

▲ ▲C

▲▲ ▲▲▲▲ ▲▲

Page 95: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 93

PLUG & SOCKET OUTLETSZONES 1 & 2, 21 & 22

Catalogue No. Entries Amps Volts Colour Pins

SO-PG016A024VSP

2 x M25 16A

24V 2P

SO-PG016A042V2P 42V 2P

SO-PG016A110V2PE 110V 1PN+E

SO-PG016A240V2PE 220V 1PN+E

SO-PG016A240V3PE 220V 3P+E

SO-PG016A415V3PE 400V 3P+E

SO-PG016A490V3PE 480V 3P+ESO-PG016A690V3PE 615V 3P+E

SO-PG016A415V4PE 400V 3PN+E

SO-PG032A240V3PE

2 x M32 32A

220V 3P+E

SO-PG032A415V3PE 400V 3P+E

SO-PG032A490V3PE 480V 3P+ESO-PG032A690V3PE 615V 3P+E

SO-PG032A415V4PE 400V 3PN+E

SO-PG063A240V3PE

2 x M50 63A

220V 3P+E

SO-PG063A415V3PE 400V 3P+E

SO-PA063A415V3PE 400V 3P+E Auxillary

SO-PG063A490V3PE 480V 3P+E

SO-PA063A490V3PE 480V 3P+E Auxillary

SO-PG063A690V3PE 615V 3P+E

SO-PA063A690V3PE 615V 3P+E Auxillary

SO-PG063A415V4PE 400V 3P+E

SO-PA063A415V4PE 400V 3P+E Auxillary

SO-PG125A240V3PE

2 x M63 125A

220V 3P+E

SO-PG125A415V3PE 400V 3P+E

SO-PA125A415V3PE 400V 3P+E Auxillary

SO-PG125A490V3PE 480V 3P+E

SO-PA125A490V3PE 480V 3P+E Auxillary

SO-PG125A690V3PE 615V 3P+E

SO-PA125A690V3PE 615V 3P+E Auxillary

SO-PG125A415V4PE 400V 3P+E

SO-PA125A415V4PE 400V 3P+E Auxillary

SELECTION GUIDE – PLUGS

Sockets

Product Catalogue No. Entries Amps Volts Colour Pins

Wall

SO-SW016A024V2P

2 x M25 16A

24V 2PSO-SW016A042V2P 42V 2PSO-SW016A110V2PE 110V 2P+E

SO-SW016A240V2PE 220V 2P+E

SO-SW016A240V3PE 220V 3P+E

SO-SW016A415V3PE 400V 3P+E

SO-SW016A490V3PE 480V 3P+E

SO-SW016A690V3PE 615V 3P+E

SO-SW016A415V4PE 400V 3PN+E

SO-SW032A240V3PE

2 x M32 32A

220V 3P+E

SO-SW032A415V3PE 400V 3P+E

SO-SW032A490V3PE 480V 3P+E

SO-SW032A690V3PE 615V 3P+E

SO-SW032A415V4PE 400V 3PN+E

SO-SW063A240V3PE

2 x M50 63A

220V 3P+E

SO-SW063A415V3PE 400V 3P+E

SO-SA063A415V3PE 400V 3P+E Auxillary

SO-SW063A490V3PE 480V 3P+E

SO-SA063A490V3PE 480V 3P+E Auxillary

SO-SW063A690V3PE 615V 3P+E

SO-SA063A690V3PE 615V 3P+E Auxillary

SO-SW063A415V4PE 400V 3PN+E

SO-SA063A415V4PE 400V 3PN+E Auxillary

SO-SW125A240V3PE

2 x M63 125A

220V 3P+E

SO-SW125A415V3P 400V 3P+E

SO-SA125A415V3PE 400V 3P+E Auxillary

SO-SW125A490V3PE 480V 3P+E

SO-SA125A490V3PE 480V 3P+E Auxillary

SO-SW125A690V3PE 615V 3P+E

SO-SA125A690V3PE 615V 3P+E Auxillary

SO-SW125A415V4PE 400V 3PN+E

SO-SA125A415V4PE 400V 3PN+E Auxillary

Panel

SO-SP016A024V2P

2 x M25 16A

24V 2PSO-SP016A042V2P 42V 2PSO-SP016A110V2PE 110V 1PN+ESO-SP016A240V2PE 220V 1PN+ESO-SP016A240V3PE 220V 3P+ESO-SP016A415V3PE 400V 3P+E

SO-SP016A490V3PE 480V 3P+E

SO-SP016A690V3PE 615V 3P+E

SO-SP016A415V4PE 400V 3PN+E

SO-SP032A240V3PE

2 x M32 32A

220V 3P+E

SO-SP032A415V3PE 400V 3P+E

SO-SP032A490V3PE 480V 3P+E

SO-SP032A690V3PE 615V 3P+E

SO-SP032A415V4PE 400V 3PN+E

Coupler

SO-SC016A024V2P

2 x M25 16A

24V 2PSO-SC016A042V2P 42V 2PSO-SC016A110V2PE 110V 1PN+ESO-SC016A240V2PE 220V 1PN+ESO-SC016A240V3PE 220V 3P+ESO-SC016A415V3PE 400V 3P+E

SO-SC016A490V3PE 480V 3P+E

SO-SC016A690V3PE 615V 3P+E

SO-SC016A415V4PE 400V 3PN+E

SO-SC032A240V3PE

2 x M32 32A

220V 3P+E

SO-SC032A415V3PE 400V 3P+E

SO-SC032A490V3PE 480V 3P+E

SO-SC032A690V3PE 615V 3P+E

SO-SC032A415V4PE 400V 3PN+E

SELECTION GUIDE – SOCKETS

Plug

& S

ocke

t O

utle

ts

Page 96: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.
Page 97: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

Wea

ther

pro

of

Lig

hti

ng

& E

ncl

osu

res

Page 98: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

96 Hazardous Areas

ALUMINIUM WEATHER-PROOF FLOODLIGHT

Range:M0874/3 Series

MATERIALS• Body – Copper-free aluminium alloy• Glass tube – Toughened glass• Ballast – Electronic• Rated voltage – AC 220V, 50/60Hz• Surface finish – Powdercoated grey

INCLUSIONS• Mounting accessories• UV resistant lens

PROTECTIONWF1, IP66

AMBIENT TEMPERATURE-40ºC Ta 50ºC

FEATURES• Convenient mounting and ease-of-service• Multiple mounting options available• Energy saving• 2600 – 2800 lm

OVERVIEWThe weather-proof floodlights are manufactured from aluminium alloy giving exceptional corrosion resistance. An impact resistant polycarbonate lens, weatherproof terminal box make this unit suitable for extreme conditions.

SELECTION GUIDE

Catalogue No.

Dimensions (mm)

Width Height Mounting Weight (kg)

ESA40FLD/C/WP 300 235 Bracket 7.0

ESA40FLD/P9/WP 485 232 Pole 90º 7.0

ESA40FLD/P2/WP 415 262 Pole 25º 7.0

ESA40FLD/W/WP 420 235 Wall 7.0

Bracket mount 90º Pole mount

Wall mount25º Pole mount

Product Description Catalogue No.

Brackets

For ceiling mount D8722/2

For general mounting D8701/2

For pendant mounting D8702/2

Straight pipe¾" galvanised steel pipe withpowdercoated surface

D732

Lamp polesFence type (set) D8725

Flange type (set) D8726

INSTALLATION ACCESSORIES

IP66

Page 99: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 97

ALUMINIUM WEATHER-PROOF FLOODLIGHT

TECHNICAL DRAWINGS

Wea

ther

proo

f

235m

m

Front View – bracket mount

300mm

▲ ▲

232m

m

Front View – 90º pole mount

485mm

▲ ▲

262m

m

235m

m

Front View – 25º pole mount

Front View – wall mount

415mm

420mm

-90º 90º

-60º

-30º 0º 30º

60º

0

80

160

240

320

400

LIGHT DISTRIBUTION CURVE

Page 100: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

98 Hazardous Areas

Range:M0242

IP65

MATERIALS• Body – Glass reinforced polyester• Rated voltage – 380V maximum

INCLUSIONS• Control box• Customised to suit application requirements

AMBIENT TEMPERATURE-40ºC ≤ Ta ≤ +40ºC / 55ºC option

OVERVIEWA range of non-metallic control boxes for applications that do not require stainless steel. Glass fibre reinforced polyester is weatherproof and anti-corrosive.

FEATURES• Individual enclosures can be combined into large units• Standard pitch between two components is 40mm• Built-in board front mounting rail type• Cable entry can be set to the top, bottom, left or right side

of the control box• Cable gland can be metal or plastic

NON-METALLIC CONTROL BOX

Page 101: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au Hazardous Areas 99

NON-METALLIC CONTROL BOX

Catalogue No.

Dimensions (mm)

Max. number of operatorsHeight

(A)Width

(B)Depth

(C)

WTBG2A 2 122 122 96

WTBG2B 2 122 122 96

WTBG4 4 220 134 96

WTBG9 9 275 160 96

WTBG16 16 352 234 96

WTBG28 28 352 352 96

WTBG56 56 352 706 161

! These enclosures are sold with controls and terminals fi tted. Empty enclosures are not available for sale.Contact your local sales engineer to discuss your specifi c requirements.

SELECTION GUIDE

TECHNICAL DRAWINGS

Front View Side View

A

▲ ▲▲ ▲B C

Wea

ther

proo

f

Page 102: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

100 Hazardous Areas

Range:M0242

IP65

MATERIALS• Body – SMC polyester• Rated voltage – 380V maximum

INCLUSIONS• Control box• 3 standard sizes• 1 – 9 installed componenets• Custom built to suit application requirements

AMBIENT TEMPERATURE-40ºC ≤ Ta ≤ +55ºC / 40ºC option

OVERVIEWA range of non-metallic control boxes for applications that do not require stainless steel. Glass fibre reinforced polyester is weatherproof and anti-corrosive.

FEATURES• Three types of standard enclosures• Explosion-proof operation head fitted to make enclosure

more reliable and durable• Easy to install• Flexible configurations• Stable and high anti-corrosion chemical performance• Two types of vertical foot trays• Ammeter, signal, switch and start/stop options available• Pendant, pipe or vertical mounting options

NON-METALLIC WEATHERPROOF CONTROL BOX

Page 103: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

brenclosures.com.au

NON-METALLIC WEATHERPROOF CONTROL BOX

Catalogue No.

Dimensions (mm)

Max. number of operatorsHeight

(A)Width

(B)Depth

(C)

WCSG2 2 170 122 96

WCSG4 4 220 134 96

WCSG9 9 275 160 96

! These enclosures are sold with controls and terminals fi tted. Empty enclosures are not available for sale.Contact your local sales engineer to discuss your specifi c requirements.

SELECTION GUIDE

TECHNICAL DRAWINGS

Wea

ther

proo

f

A

▲ ▲▲ ▲B C

Front View Side View

Page 104: B&R Enclosures HAZARDOUS AREAS · the hazardous area market. ... 10 Hazardous Areas LIGHTING ... The table below is a guide to zone classification of hazardous areas.

Head Office 51 Stradbroke Street Heathwood QLD 4110 AustraliaPO Box 1151 Browns Plains BC QLD 4118 AustraliaT: +61 7 3714 1000 F: +61 7 3714 1081

QLD Office – Sales & Warehouse51 Stradbroke Street Heathwood QLD 4110 AustraliaPO Box 1151 Browns Plains BC QLD 4118 AustraliaT: +61 7 3714 1111 F: +61 7 3714 1091

North QLD Office – Sales & Warehouse25 Dalrymple Road Garbutt QLD 4814 AustraliaPO Box 7615 Garbutt QLD 4815 AustraliaT: +61 7 4727 1900 F: +61 7 4755 0675

NSW & ACT Office – Sales & WarehouseUnit 12/100 Belmore Road North Riverwood NSW 2210 AustraliaPO Box 90 Riverwood NSW 2210 AustraliaT: +61 2 9915 9555 F: +61 2 9584 0055

Newcastle – DistributionRoss Joice Agencies Pty Ltd109-111 Broadmeadow Road Broadmeadow NSW 2292 AustraliaT: +61 2 4961 4433 F: +61 2 4961 2498

VIC & TAS Office – Sales & Warehouse50-52 Sunmore Close Heatherton VIC 3202 AustraliaT: +61 3 9552 0552 F: +61 3 9551 8636

SA & NT Office – Sales & Warehouse505 Grand Junction Way Wingfield SA 5013 AustraliaT: +61 8 8417 6222 F: +61 8 8268 3675

Northern Territory – DistributionJewell Distributors Pty LtdCnr Hidden Valley & Beaton Roads Berrimah NT 0828 AustraliaT: +61 8 8947 0870 F: +61 8 8947 0764

WA Office – Sales & Warehouse6 Montgomery Way Malaga WA 6090 AustraliaT: +61 8 6310 4777 F: +61 8 9249 6776

National SalesT: 1300 Enclosures (1300 362 567)F: 1300 796 599E: [email protected]