Date post: | 25-May-2015 |
Category: |
Health & Medicine |
Upload: | jean-marc-retrouvey |
View: | 571 times |
Download: | 2 times |
Bracketing: A Basic Teaching Module for Dental
Assistants
Dr Jean Marc Retrouvey
McGill University, Faculty of Dentistry
General steps in bracket bonding
Prophylaxis
• Pre-bonding prophylaxis procedure – Using oil-free pumice mixed with water: tooth surfaces where the brackets are to be bonded must be cleaned.
Isolation of teeth (Cheek retractors)
Acid Etching
Proceed by quadrants
Apply a light coat of resin
Select the proper bracket
Position the bracket as precisely as possible
Use a mirror to verify if the bracket is centered on the crown
Excess composite
Remove excess composite around the bracket with a scaler or an explorer before light curing. If not, it will encourage plaque accumulation.
Use height gage properly
In the canine, premolar and molar regions, the gauge is placed parallel with the occlusal plane
Verify bracket positioning
Tip and Torque in the position of incisors
GENERAL ORTHODONTIC INSTRUMENTATION FOR FIXED
APPLIANCES
Examination kit
• Cotton pliers. This instrument is used to hold brackets securely when placing them onto the tooth surface.
• Explorer. In orthodontics, this is commonly used to remove elastics, in place of a scaler. In addition, it can be used to remove excess resin after bracket placement.
• Mouth mirror. This is used to verify the MD position of the bracket
Bidirectional ligature director. This instrument is used to tuck metal ligatures under the archwire, to keep the ends free from irritating the soft tissue.
Bracket height gauge. This is used to measure the distance from the occlusal/incisal surface to the bracket slot.
Distal-end cutter. This instrument cuts the distal end of archwire while holding the cut end. Therefore, this can be used in an intraoral setting.
Mathieu plier. This is an instrument that locks (like a haemostat) and braces small metal parts. In general, they are used to hold and twist the ends of metal ligatures, and also to place elastic ligatures.
Ligature-cutting plier. To avoid damage to the instrument, these pliers must only be used to cut small gauges of “dead soft” stainless steel ligature wire (<0.014”) intra orally.
Hard wire cutter. This instrument is designed to cut thick wire (> 0.014”) extraorally.
Ladmore composite instrument. This non-stick instrument is used to place resin onto the base of the bracket.
Cheek and lip retractor. This is an adjustable device that retracts away the lips and cheeks to maximize visibility and to minimize salivary contamination.
Debonding plier. This instrument is used to remove brackets by holding the bracket mesio-distally and applying slight pressure by torquing or turning in a clockwise motion.