SP-1000XPanic Device Power
Controller
Access Control PanelBY OTHERS
Dry Output ContactsRated 1.0A @ 28vdc min.
Lock release time to be controlled by access system controller
NC C NONC C NO
dps input
rex input
(888) 284-4774
© 2015
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
FOR REFERENCE ONLY© 2018
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
Function Statement:From exterior - locked condition: From exterior - unlocked condition: From interior - locked condition: From interior - unlocked condition: General:
SGL_etwbutt_RXEL1690_SP1000X.vsdTitle:
Drawn By:
Door: 110BProject: 63-159706 OP / SO#3506101
HWSET: 9.0 / ARCH: 41.01/18/2018Date: 1/18/20181/18/2018Date Printed: Last Revised:
2Pg: 1 OFCody Richardson For: Kawneer Company
5:33:03 PMSO: 132930
Access by presenting valid credential to retract exit device latchbolts electronically. Manual entry by key override via cylinder control.Door to remain locked unless exit device latchbolts held retracted electronically by access system.
Free egress at all times by means of exit device. Free egress at all times by means of exit device.
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.5) It is considered good electrical practice to run spare wires at any location that may be difficult to access after construction.
Interior Exterior
Wire gage, type and number of conductors, per equipment manufacturer.
Card Reader
by Others
Electrical breaker panel
Line voltage wire type and gage, per local
electrical code.
Securitron M-GYDoor Position Switch
Electrical Circuit LegendRed = (+)VDC Power
Black = (-) VDC PowerGreen = Signaling Blue = Activation
Violet = Monitoring/SupervisoryBrown = AC High Voltage
EL-1690-NLOP
Red +24vdc
Gray LX NOWht LX COM
Vio LX NC
Yel RX NC
Red/Grn RX COM
Blu RX NO
SP1000X to be supplied
BY KAWNEER
McKinney T4A3786-QC8
Electric Thru-WireButt Hinge
14 AWG - 100ft max12 AWG - 200ft max
(888) 284-4774
© 2014
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
FOR REFERENCE ONLY© 2018
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
SGL_etwbutt_RXEL1690_SP1000X.vsdTitle:
Drawn By:
Door: 110BProject: 63-159706 OP / SO#3506101
HWSET: 9.0 / ARCH: 41.01/18/2018Date: 1/18/20181/18/2018Date Printed: Last Revised:
2Pg: 2 OFCody Richardson For: Kawneer Company
5:33:03 PMSO: 132930
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.5) It is considered good electrical practice to run spare wires at any location that may be difficult to access after construction.
Interior Exterior
Electrical Breaker Panel
Yale 782Power Supply
110-120VAC 50/60Hz / 750mA
Access Control Panel
BY OTHERS
Card Reader
Box Size by supplier
Line voltage wire type, gage and
number of conductors by electrical contractor. 18 AWG / 3 Pair
Wire type, gage and number of conductors
by hardware manufacturer.2 Conductor
14 AWG up to 100ft12 AWG up to 200ft
SP-1000XPanic Device
Power Controller
13"H x 12.5"W x 3.25"D
Input 115vac / 6.3amp
BY OTHERS
18 AWG / 1 Pair
ON
1 2 3 4
Man
ual T
est
FA
LED
SIN
1IN
2
Bat
AC
CN
OD
elay
ed 1
Follo
wer
1C
NO
Supe
rvis
ion
CN
OD
elay
ed 2
Follo
wer
2C
NO
CN
O24
VD
C+
-12
VD
C+
-
GN
D
GN
D
GN
D
FAC
P
IN1
IN2G NL Bat
-
Bat
+
- + - +
Out 1 Out 2
SP-1000XPanic Device Power
Controller
Access Control PanelBY OTHERS
Dry Output ContactsRated 1.0A @ 28vdc min.
Lock release time to be controlled by access system controller
NC C NONC C NO
dps input
rex input
(888) 284-4774
© 2015
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
FOR REFERENCE ONLY© 2018
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
Function Statement:From exterior- locked condition: From exterior - unlocked condition: From interior - locked condition: From interior - unlocked condition: General:
Pair_RXEL1690_SP1000X.vsdTitle:
Drawn By:
Door: 2801CCProject: 63-159706 OP / SO#3506101
HWSET: 13.0 / ARCH: 601/18/2018Date: 1/18/20181/18/2018Date Printed: Last Revised:
2Pg: 1 OFCody Richardson For: Kawneer Company
5:21:14 PMSO: 132930
Access by presenting valid credential to retract exit device latchbolts electronically. Manual entry by key override on active leaf via cylinder control.Doors to remain locked unless exit device latchbolts held retracted electronically by access system.
Free egress at all times by means of exit device. Request to exit signal sent to access system upon egress for forced door alarm event shunting. Free egress at all times by means of exit device. Request to exit signal sent to access system upon egress for forced door alarm event shunting.
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.5) It is considered good electrical practice to run spare wires at any location that may be difficult to access after construction.
Interior Exterior
Wire gage, type and number of conductors, per equipment manufacturer.
Card Reader
by Others
Electrical breaker panel
Line voltage wire type and gage, per local
electrical code.
Securitron M-GYDoor Position Switch
Electrical Circuit LegendRed = (+)VDC Power
Black = (-) VDC PowerGreen = Signaling Blue = Activation
Violet = Monitoring/SupervisoryBrown = AC High Voltage
RX-EL-1690-NLOP RX-EL-1690-EO
Red +24vdc
Gray LX NOWht LX COM
Vio LX NC
Yel RX NC
Red/Grn RX COM
Blu RX NO
Red +24vdc
Gray LX NOWht LX COM
Vio LX NC
Yel RX NC
Red/Grn RX COM
Blu RX NO
SP1000X to be supplied
BY KAWNEER
14 AWG - 100ft max12 AWG - 200ft max
Von Duprin EPT-10Electric Power Transfer
(888) 284-4774
© 2014
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
FOR REFERENCE ONLY© 2018
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
Pair_RXEL1690_SP1000X.vsdTitle:
Drawn By:
Door: 2801CCProject: 63-159706 OP / SO#3506101
HWSET: 13.0 / ARCH: 601/18/2018Date: 1/18/20181/18/2018Date Printed: Last Revised:
2Pg: 2 OFCody Richardson For: Kawneer Company
5:21:14 PMSO: 132930
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.5) It is considered good electrical practice to run spare wires at any location that may be difficult to access after construction.
Interior Exterior
Electrical Breaker Panel
Yale 782Power Supply
110-120VAC 50/60Hz / 750mA
Access Control Panel
BY OTHERS
Card Reader
Box Size by supplier
Line voltage wire type, gage and
number of conductors by electrical contractor.
18 AWG / 2 Pair
18 AWG / 6 Pair
Wire type, gage and number of conductors
by hardware manufacturer.
18 AWG / 1 Pair
18 AWG / 1 Pair
2 Conductor 14 AWG up to 100ft12 AWG up to 200ft
2 Conductor 14 AWG up to 100ft12 AWG up to 200ft
SP-1000XPanic Device
Power Controller
13"H x 12.5"W x 3.25"D
Input 115vac / 6.3amp
BY OTHERS
ON
1 2 3 4
Man
ual T
est
FA
LED
SIN
1IN
2
Bat
AC
CN
OD
elay
ed 1
Follo
wer
1C
NO
Supe
rvis
ion
CN
OD
elay
ed 2
Follo
wer
2C
NO
CN
O24
VD
C+
-12
VD
C+
-
GN
D
GN
D
GN
D
FAC
P
IN1
IN2G NL Bat
-
Bat
+
- + - +
Out 1 Out 2
SP-1000XPanic Device Power
Controller
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.5) It is considered good electrical practice to run spare wires at any location that may be difficult to access after construction.
(888) 284-4774
© 2017
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
FOR REFERENCE ONLY© 2017
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
Function Statement:From exterior- locked condition: From exterior - unlocked condition: From interior - locked condition: From interior - unlocked condition: General:
Pair_RX-EL-1690_SP1000X.vsdTitle:
Drawn By:
Door: 628BProject: PO#62-159033op_SO#3497740
HWSET: 1.0/ARCH: 1812/11/2017Date: 12/11/2017Date Printed: Last Revised:
2Pg: 1 OFCody Richardson For: Kawneer Company
5:24:15 PMSO: 132477
Access by presenting valid credential to retract electric exit device latchbolts. Manual entry by key on active leaf.Doors to remain locked unless active electric exit device latchbolts held retracted by access system.
Free egress at all times by means of exit device. RX signal sent to access system upon egress via exit device push pad for forced door alarm event (DPS) shunting.Free egress at all times by means of exit device. RX signal sent to access system upon egress via exit device push pad for forced door alarm event (DPS) shunting.
Electrical breaker panel
Access Control PanelBY OTHERS
Dry Output ContactsRated 1.0A @ 28vdc min.
Lock release time to be controlled by access system controller
NC C NONC C NO
Card Reader by
Others
Line voltage wire type and gage, per
local electrical code.
Wire gage, type and number of conductors, per equipment manufacturer.
Von Duprin EPT-10Electric Power Transfer
14 AWG - 100ft max12 AWG - 200ft max
dps input
Door Position SwitchBY OTHERS
Interior ExteriorElectrical Circuit Legend
Red = (+)VDC PowerBlack = (-) VDC Power
Green = Signaling Blue = Activation
Violet = Monitoring/SupervisoryBrown = AC High Voltage
rx input
RX-EL-1692NL-OP RX-EL-1690EO
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.5) It is considered good electrical practice to run spare wires at any location that may be difficult to access after construction.
(888) 284-4774
© 2014
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
FOR REFERENCE ONLY© 2017
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
Pair_RX-EL-1690_SP1000X.vsdTitle:
Drawn By:
Door: 628BProject: PO#62-159033op_SO#3497740
HWSET: 1.0/ARCH: 18
12/11/2017Date: 12/11/2017Date Printed: Last Revised:
2Pg: 2 OFCody Richardson For: Kawneer Company
5:24:15 PMSO: 132477
Electrical Breaker Panel Access Control
PanelBY OTHERS
Card Reader
Box Size by supplier
Line voltage wire type, gage and
number of conductors by electrical contractor.
Wire type, gage and number of conductors
by hardware manufacturer.
2 Conductor 14 AWG up to 100ft12 AWG up to 200ft
2 Conductor 14 AWG up to 100ft12 AWG up to 200ft
18 AWG / 6 Pair
Interior Exterior
18 AWG / 2 Pair
SP-1000XPanic Device
Power Controller
13"H x 12.5"W x 3.25"D
Input 115vac / 6.3amp
18 AWG / 1 Pair 18 AWG / 1 Pair
ON
1 2 3 4
Man
ual T
est
FA
LED
SIN
1IN
2
Bat
AC
CN
OD
elay
ed 1
Follo
wer
1 CN
OSu
perv
isio
nC
NO
Del
ayed
2Fo
llow
er 2 C
NO
CN
O24
VD
C
+-
12 V
DC
+-
GN
D
GN
D
GN
D
FAC
P
IN1
IN2G NL B
at -
Bat
+
- + - +
Out 1 Out 2
SP-1000XPanic Device Power
Controller
(888) 284-4774
© 2014
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
FOR REFERENCE ONLY© 2014
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
Function Statement:From exterior- locked condition: From exterior - unlocked condition: From interior - locked condition: From interior - unlocked condition: General:
First Choice EL Device 2 Pair Active SP-1000X AOBO.vsdTitle:
Drawn By:
Door: Example A/BProject: Sample Diagram
HWSET: 1A9/14/2017Date: 9/14/2017Date Printed: Last Revised:
1Pg: 1 OFCody Richardson For: First Choice Building Products
11:58:41 AMSO:
Access by presenting valid credential at reader interface to retract active leaf electric exit device latch and enable exterior actuator use. Doors to remain locked unless electric exit device latch held retracted by access system or momentarily unlocked by push button.
Free egress at all times by means of exit device or by pressing interior handicap actuator to unlock and swing door. Free egress at all times by means of exit device or by pressing interior handicap actuator to unlock and swing door.
This is a basic/generic sample diagram for reference only. For project specific wiring diagrams, please contact Special Projects Group.
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.
Card Reader
by Others
+-
This device is polarity sensitive. Please observe polarity when connecting the provided wiring harness.
+-
This device is polarity sensitive. Please observe polarity when connecting the provided wiring harness.
Exit
Optional momentary switch. Unlock with
depression.
Exit
Optional momentary switch. Unlock with
depression.
Access Control Panel
Dry Output ContactsRated 1.0A @ 28vdc min.
Lock release time to be controlled by access system controller
NC C NONC C NO
Electrical breaker panel
Line voltage wire type and gage, per local electrical code.
Card Reader
by Others
Wire gage, type and number of conductors, per equipment manufacturer.
Wire gage, type and number of conductors, per equipment manufacturer.
Interior ExteriorExterior
NOTE:
Optional power transfers are available. Please note variations in wire size and maximum run length for these options.
14 AWG - 35 ft max12 AWG - 55 ft max10 AWG - 95 ft max
POWER TRANSFERS
NOTE: Make certain to maintain consistent wire color across the transfer to maintain polarity.
RED REDPURPLE PURPLEYELLOW YELLOW
GREY GREY
Out 2
14 AWG – 40ft max12 AWG – 60ft max10 AWG – 100ft max
With EPT
Auto Operator
Push to Open
C NO
Push to Open
C NO
ActivationLock Relay
First Choice EL-3000
+-First Choice 3000 First Choice EL-3000
+-First Choice 3000
Access Control PanelBY OTHERS
Dry Output ContactsRated 1.0A @ 28vdc min.
Lock release time to be controlled by access system controller
NC C NONC C NO
(888) 284-4774
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
Function Statement:From exterior- locked condition: Access by presenting valid card to unlock active leaf and make exterior actuator available to swing active leaf.From exterior - unlocked condition: Doors to remain locked unless active leaf held unlocked by access system. Press actuator to swing active leaf.From interior - locked condition: Free egress by means of exit device. Interior actuator always available to swing door.From interior - unlocked condition: Free egress by means of exit device. Interior actuator always available to swing door.General: This is a basic generic wiring diagram. For a project specific wiring diagram contact your Kawneer representative.
FOR REFERENCE ONLY
Paneline EL 1 Active w Operator SP-1000X.vsdTitle:
Drawn By:
Door: Kawneer PanelineProject: Paneline EL 1 Active w Operator
Heading: Paneline EL
3/19/2014Date: 2/19/20142/19/2014Date Printed: Last Revised:
1Pg: 1 OFCody Richardson For: Kawneer Company, Inc.
4:09:35 PM
© 2014
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
Card Reader by
Others
Electrical breaker panel
+
-
This device is polarity sensitive. Please observe polarity when connecting the provided wiring harness.
PUSH
+-PUSH
Auto Operator
Push to Open
C NO
Push to Open
C NO
Activation
Lock Relay
NOTE:
Optional power transfers are available. Please note variations in wire size and maximum run length for these options.
14 AWG - 35 ft max12 AWG - 55 ft max10 AWG - 95 ft max
POWER TRANSFERS
NOTE:Make certain to maintain consistent wirecolor across the transfer to maintain polarity.
RED REDPURPLE PURPLEYELLOW YELLOW
GREY GREY
Handicap Actuator
Wire gage, type and number of conductors, per equipment manufacturer.
14 AWG – 40ft max12 AWG – 60ft max10 AWG – 100ft max
With EPT
Line voltage wire type and gage, per local electrical code.
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.
Interior Exterior
ON
1 2 3 4
Man
ual T
est
FA
LED
SIN
1IN
2
Bat
AC
CN
OD
elay
ed 1
Follo
wer
1C
NO
Sup
ervi
sion
CN
OD
elay
ed 2
Follo
wer
2C
NO
CN
O24
VD
C+
-12
VD
C+
-
GN
D
GN
D
GN
D
FAC
P
IN1
IN2G NL Bat
-
Bat
+
- + - +
Out 1 Out 2
ON
1 2 3 4
Man
ual T
est
FA
LED
SIN
1IN
2
Bat
AC
CN
OD
elay
ed 1
Follo
wer
1C
NO
Sup
ervi
sion
CN
OD
elay
ed 2
Follo
wer
2C
NO
CN
O24
VD
C+
-12
VD
C+
-
GN
D
GN
D
GN
D
FAC
P
IN1
IN2G NL Bat
-
Bat
+
- + - +
Out 1 Out 2
(888) 284-4774
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
Function Statement:From exterior- locked condition: Access by presenting valid credential to unlock door.From exterior - unlocked condition: Doors to remain locked unless held unlocked by access control system.From interior - locked condition: Free egress at all times by means of exit device.From interior - unlocked condition: Free egress at all times by means of exit device.General: This is a basic generic wiring diagram. For a project specific wiring diagram contact your Kawneer representative.
FOR REFERENCE ONLY
Paneline EL Exit Device 1 Single SP-1000X.vsdTitle:
Drawn By:
Door: Kawneer Paneline
Project: Paneline EL 1 single door
Heading: Paneline EL
5/5/2014Date: 01/22/20145/5/2014Date Printed: Last Revised:
1Pg: 1 OFCody Richardson For: Kawneer Company, Inc.
5:14:26 PM
© 2014
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
Exit
NO
C
NC
NC C NO
Access Control Panel
Dry Output ContactsRated 1.0A @ 28vdc min.
Lock release time to be controlled by access system controller
Card Reader by
Others
Electrical breaker panel
Line voltage wire type and gage, per local electrical code.
14 AWG – 40ft max12 AWG – 60ft max10 AWG – 100ft max
With EPT
NOTE:
Optional power transfers are available. Please note variations in wire size and maximum run length for these options.
14 AWG - 35 ft max12 AWG - 55 ft max10 AWG - 95 ft max
POWER TRANSFERS
NOTE:Make certain to maintain consistent wirecolor across the transfer to maintain polarity.
RED REDPURPLE PURPLEYELLOW YELLOW
GREY GREY
+
-
This device is polarity sensitive. Please observe polarity when connecting the provided wiring harness.
Optional momentary switch. Unlock with depression.
PUSH
+-
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.
Wire gage, type and number of conductors, per equipment manufacturer.
Electric Power Transfer
ON
1 2 3 4
Man
ual T
est
FA
LED
SIN
1IN
2
Bat AC
CN
OD
elay
ed 1
Follo
wer
1C
NO
Supe
rvis
ion
CN
OD
elay
ed 2
Follo
wer
2C
NO
CN
O24
VD
C+
-12
VD
C+
-
GN
D
GN
D
GN
D
FAC
P
IN1
IN2G NL Bat
-
Bat
+
- + - +
Out 1 Out 2
(888) 284-4774
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
Function Statement:From exterior- locked condition: Access by presenting valid credential to unlock active leaf.From exterior - unlocked condition: Doors to remain locked unless held unlocked by access control system.From interior - locked condition: Free egress at all times by means of exit device.From interior - unlocked condition: Free egress at all times by means of exit device.General: This is a basic generic wiring diagram. For a project specific wiring diagram contact your Kawneer representative.
FOR REFERENCE ONLY
Paneline EL Exit Device 1 Pair 1 Active SP1000X.vsdTitle:
Drawn By:
Door: Kawneer PanelineProject: Paneline EL 1 Pair with 1 Active
Heading: Paneline EL
5/5/2014Date: 5/5/201401/20/2014Date Printed: Last Revised:
1Pg: 1 OFCody Richardson For: Kawneer Company, Inc.
5:17:29 PM
© 2014
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
NC C NO
Access Control Panel
Dry Output ContactsRated 1.0A @ 28vdc min.
Lock release time to be controlled by access system controller
Card Reader by
Others
Electrical breaker panel
Line voltage wire type and gage, per local
electrical code.
NOTE:
Optional power transfers are available. Please note variations in wire size and maximum run length for these options.
14 AWG - 35 ft max12 AWG - 55 ft max10 AWG - 95 ft max
POWER TRANSFERS
NOTE:Make certain to maintain consistent wirecolor across the transfer to maintain polarity.
RED REDPURPLE PURPLEYELLOW YELLOW
GREY GREY
+
-
This device is polarity sensitive. Please observe polarity when connecting the provided wiring harness.
PUSH
+-PUSH
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.
Wire gage, type and number of conductors, per equipment manufacturer.
Exterior
14 AWG - 40ft max12 AWG - 60ft max
10 AWG - 100ft max
Exit
NO
C
NC
Optional momentary switch. Unlock with depression.
Interior
ON
1 2 3 4
Man
ual T
est
FA
LED
SIN
1IN
2
Bat AC
CN
OD
elay
ed 1
Follo
wer
1C
NO
Sup
ervi
sion
CN
OD
elay
ed 2
Follo
wer
2C
NO
CN
O24
VD
C+
-12
VD
C+
-
GN
D
GN
D
GN
D
FAC
P
IN1
IN2G NL Bat
-
Bat
+
- + - +
Out 1 Out 2
(888) 284-4774
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
Function Statement:From exterior- locked condition: Access by presenting valid credential to unlock doors.From exterior - unlocked condition: Doors to remain locked unless held unlocked by access control system.From interior - locked condition: Free egress at all times by means of exit device.From interior - unlocked condition: Free egress at all times by means of exit device.General: This is a basic generic wiring diagram. For a project specific wiring diagram contact your Kawneer representative.
FOR REFERENCE ONLY
Paneline EL Exit Device 1 Pair 2 Active SP1000X.vsdTitle:
Drawn By:
Door: Kawneer Paneline
Project: Paneline EL 1 Pair with 2 Active
Heading: Paneline EL
5/5/2014Date: 01/20/201401/20/2014Date Printed: Last Revised:
1Pg: 1 OFCody Richardson For: Kanweer Company Inc.
5:18:41 PM
© 2014
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
Exit
NO
C
NC
NC C NO
Access Control Panel
Dry Output ContactsRated 1.0A @ 28vdc min.
Lock release time to be controlled by access system controller
Card Reader by
Others
Electrical breaker panel
Line voltage wire type and
gage, per local electrical code.
14 AWG – 40ft max12 AWG – 60ft max10 AWG – 100ft max
With EPT
NOTE:
Optional power transfers are available. Please note variations in wire size and maximum run length for these options.
14 AWG - 35 ft max12 AWG - 55 ft max10 AWG - 95 ft max
POWER TRANSFERS
NOTE:Make certain to maintain consistent wirecolor across the transfer to maintain polarity.
RED REDPURPLE PURPLEYELLOW YELLOW
GREY GREYOptional momentary switch.
Unlock with depression.
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.
+
-
This device is polarity sensitive. Please observe polarity when connecting the provided wiring harness.
+
-
This device is polarity sensitive. Please observe polarity when connecting the provided wiring harness.
PUSH
+-PUSH
+ -
Set Dip Switch 1- ONFor Sequential Mode
Wire gage, type and number of conductors, per equipment manufacturer.
Interior Exterior
ON
1 2 3 4
Man
ual T
est
FA
LED
SIN
1IN
2
Bat
AC
CN
OD
elay
ed 1
Follo
wer
1C
NO
Sup
ervi
sion
CN
OD
elay
ed 2
Follo
wer
2C
NO
CN
O24
VD
C+
-12
VD
C+
-
GN
D
GN
D
GN
D
FAC
P
IN1
IN2G NL Bat
-
Bat
+
- + - +
Out 1 Out 2
(888) 284-4774
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
Function Statement:From exterior- locked condition: Access by presenting valid credential to unlock door.From exterior - unlocked condition: Doors to remain locked unless held unlocked by access control system.From interior - locked condition: Free egress at all times by means of exit device.From interior - unlocked condition: Free egress at all times by means of exit device.General: This is a basic generic wiring diagram. For a project specific wiring diagram contact your Kawneer representative.
FOR REFERENCE ONLY
Paneline EL Exit Device 1 Single SP-1000X.vsdTitle:
Drawn By:
Door: Kawneer Paneline
Project: Paneline EL 1 single door
Heading: Paneline EL
5/5/2014Date: 01/22/20145/5/2014Date Printed: Last Revised:
1Pg: 1 OFCody Richardson For: Kawneer Company, Inc.
5:14:26 PM
© 2014
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
Exit
NO
C
NC
NC C NO
Access Control Panel
Dry Output ContactsRated 1.0A @ 28vdc min.
Lock release time to be controlled by access system controller
Card Reader by
Others
Electrical breaker panel
Line voltage wire type and gage, per local electrical code.
14 AWG – 40ft max12 AWG – 60ft max10 AWG – 100ft max
With EPT
NOTE:
Optional power transfers are available. Please note variations in wire size and maximum run length for these options.
14 AWG - 35 ft max12 AWG - 55 ft max10 AWG - 95 ft max
POWER TRANSFERS
NOTE:Make certain to maintain consistent wirecolor across the transfer to maintain polarity.
RED REDPURPLE PURPLEYELLOW YELLOW
GREY GREY
+
-
This device is polarity sensitive. Please observe polarity when connecting the provided wiring harness.
Optional momentary switch. Unlock with depression.
PUSH
+-
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.
Wire gage, type and number of conductors, per equipment manufacturer.
Electric Power Transfer
ON
1 2 3 4
Man
ual T
est
FA
LED
SIN
1IN
2
Bat AC
CN
OD
elay
ed 1
Follo
wer
1 CN
OSu
perv
isio
nC
NO
Del
ayed
2Fo
llow
er 2 C
NO
CN
O24
VD
C
+-
12 V
DC
+-
GN
D
GN
D
GN
D
FAC
P
IN1
IN2G NL B
at -
Bat
+
- + - +
Out 1 Out 2
(888) 284-4774
© 2014
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
FOR REFERENCE ONLY© 2014
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
Function Statement:From exterior- locked condition:From exterior - unlocked condition:From interior - locked condition: From interior - unlocked condition:General:
Paneline EL Exit Device 2 Pair 1 Active SP-1000X.vsdTitle:
Drawn By:
Door: Project:
Heading:
3/19/2014Date: 3/19/20143/19/2014Date Printed: Last Revised:
1Pg: 1 OFCody Richardson For: Kawneer Company, Inc.
10:44:32 AMSO: SPG SO
Access by presenting card to unlock active leaf.Doors to remain locked unless held unlocked by access system or momentarily unlocked by push button.Free egress at all times by means of exit device.Free egress at all times by means of exit device.This is a absic and generic diagram. For a project specific wiring diagram, please contact your Kawneer representative.
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.
Card Reader
by OthersPUSH
+-PUSH
+-
This device is polarity sensitive. Please observe polarity when connecting the provided wiring harness.
PUSH
+-PUSH
+-
This device is polarity sensitive. Please observe polarity when connecting the provided wiring harness.
Exit
NOC
NC
Optional momentary switch. Unlock with
depression.
Exit
NOC
NC
Optional momentary switch. Unlock with
depression.
Access Control Panel
Dry Output ContactsRated 1.0A @ 28vdc min.
Lock release time to be controlled by access system controller
NC C NONC C NO
Electrical breaker panel
Line voltage wire type and gage, per local electrical code.
Card Reader
by Others
Wire gage, type and number of conductors, per equipment manufacturer.
Wire gage, type and number of conductors, per equipment manufacturer.
With EPT or Door Loop14 AWG - 40ft max12 AWG - 60ft max
10 AWG - 100ft max
Dip 1 = OFFFor Independent Mode
Interior ExteriorExterior
NOTE:
Optional power transfers are available. Please note variations in wire size and maximum run length for these options.
14 AWG - 35 ft max12 AWG - 55 ft max10 AWG - 95 ft max
POWER TRANSFERS
NOTE:Make certain to maintain consistent wirecolor across the transfer to maintain polarity.
RED REDPURPLE PURPLEYELLOW YELLOW
GREY GREY
Out 2
ON
1 2 3 4
Man
ual T
est
FA
LED
SIN
1IN
2
Bat AC
CN
OD
elay
ed 1
Follo
wer
1C
NO
Supe
rvis
ion
CN
OD
elay
ed 2
Follo
wer
2C
NO
CN
O24
VD
C+
-12
VD
C+
-
GN
D
GN
D
GN
D
FAC
P
IN1
IN2G NL Ba
t -
Bat
+
- + - +
Out 1 Out 2
(888) 284-4774
These drawings are the sole and exclusive property of Special Projects Group and contain sensitive privileged or confidential information which may be used only for its benefit. The disclosure of these drawings to unauthorized persons is strictly prohibited. This document and all copies must be returned upon demand.
COPYRIGHT SPECIAL PROJECTS GROUP, INC.
Function Statement:From exterior- locked condition:From exterior - unlocked condition:From interior - locked condition: From interior - unlocked condition:General :
FOR REFERENCE ONLY
Paneline EL Exit with Rosslare SP-1000X.vsdTitle:
Drawn By:
Door: Kawneer PanelineProject: Paneline EL with Rosslare Key Pad
Heading: Paneline EL
3/19/2014Date: 3/19/20143/19/2014Date Printed: Last Revised:
1Pg: 1 OFCMR For: Kawneer Company, Inc.
10:47:02 AM
© 2014
This drawing is not a substitute for qualified field technicians. One hour of telephone support is available without charge.
SO: N/A
Access by means of presenting valid credential or entering valid code.Door to remain locked unless toggled unlocked by valid toggle code.
Free egress at all times by means of exit device.Free egress at all times by means of exit device.
Diagram for use with “stand alone” Rosslare AC-G43 key pad or AC-G44 key pad / proximity card reader.
321
64
57 89 0
* #
RBk
GnWh
Pr GrBnBl
YlOr
Exit
NO
C
NC
Optional remote release
button
Rosslare AC-G43or
Rosslare AC-G44
+
-
This device is polarity sensitive. Please observe polarity when connecting the provided wiring harness.
Electrical breaker panel
COMNO
1) Verify that each component requiring or supplying power has been configured for proper system voltage before applying power.
NOTES:
2) All wires to be 18 awg 100' max unless otherwise noted on drawing. Refer to manufacturers instructions for proper wire gauge on any power supply, electric device or electrified lock hardware. Manufacturers requirements take precedence. 3) All line voltage power to be I/A/W local electrical code.
4) All low voltage wires to be stranded copper unless superseded by local electrical code or electric device manufacturer.
NOTE:
Optional power transfers are available. Please note variations in wire size and maximum run length for these options.
14 AWG - 35 ft max12 AWG - 55 ft max10 AWG - 95 ft max
POWER TRANSFERS
NOTE:Make certain to maintain consistent wirecolor across the transfer to maintain polarity.
RED REDPURPLE PURPLEYELLOW YELLOW
GREY GREY
Electric Power Transfer
PUSH
+-
Out 2
14 AWG - 40ft max12 AWG - 60ft max
10 AWG - 100ft max
Line voltage wire type and gage, per
local electrical code.
Interior Exterior