  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    1/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    1/49

    1. INTRODUCTION

    In developing the calculations, the Eurocodes and Romanian rules in force were taken

    into consideration:

    PD 165 Standard on structures and calculation of the highway with bridges and culverts

    and precast superstructure cast

    SR EN 1990:2004 Eurocode : Basis of Structural Design

    SR EN 1991-1-1:2004 Eurocode 1 : Actions on structures / Part 1-1 : General actions -

    specific weight , their weight , the payload for buildings and SR EN 1991-2 : 2004 Part 2:

    traffic impact on bridges

    SR EN 1992-1-1 Eurocode 2 : Design of concrete structures / Part 1-1 : General rules and

    rules for buildings EN 1992-2 and SR : 2006 Part 2: Concrete bridges - Design and detailing

    rules

    SR EN 1992-2:2006 - Design of concrete structures / Part 2: Concrete Bridges. Design and

    detailing rules

    SR EN 1997-1:2004 Eurocode 7: Geotechnical design / Part 1: General

    SR EN 1998-1:2004 Eurocode 8: Design of structures for earthquake resistance / Part 1 :

    General rules , seismic actions and rules for buildings EN 1998-2 and SR : 2004 Part 2:

    Bridges

    STAS 2561/3-90 Terrain for foundation / PILES / General design

    STAS 3221-86 Highway bridges . Convoys type and load classes

    STAS 10111/2-87 Bridges railways and road / superstructure concrete, reinforced and

    prestressed concrete / Design specifications

    P100-1:2013 Seismic Design Code - Part I - Design provisions for buildings

    2. MATERIALS

    2.1 Existing structural elements

    ruler and poles - concrete B400 mark - equivalent class C25/30- fck= 25 MPa (resistance to compression feature in MPa)

    - fcd= 16.67 MPa (design compression resistance in MPa)

    - E = 32000 MPa (the modulus of elasticity in MPa)

    Metal Fittings PC52

    - fyk= 355 MPa (flow limit feature of fittings for concrete in MPa)

    - ftk= 520 MPa (Tensile strength characteristic of fittings for concrete in MPa)

    - fyd = 308.7 MPA (Tensile strength calculation of reinforcement for concrete in

    MPa)

    - Es= 210 GPa (the modulus of elasticity in GPa)

    2.2 Structural elements designed

    Plate Slab finishing cast concrete beams with small- openings C35/45

    - fck= 35 MPa (resistance to compression feature in MPa)

    - fcd= 23.33 MPa (design compression resistance in MPa)

    - E = 34000 MPa (the modulus of elasticity in MPa)

    Beams with large openings - Concrete C40/50

    - fck= 40 MPa (resistance to compression feature in MPa)

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    2/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    2/49

    - fcd= 26.67 MPa (design compression resistance in MPa)

    - E = 35000 MPa (the modulus of elasticity in MPa)

    -

    Fittings BST 500S (C)

    - fyk= 500 MPa (flow limit feature of fittings for concrete in MPa)

    - ftk= 550 MPa (Tensile strength characteristic of fittings for concrete, in MPa)- fyd= 434 MPA (Tensile strength calculation of fittings for concrete in MPa)

    - Es= 210 GPa (the modulus of elasticity in GPa)

    Metal floor - Steel S355

    - fyk= 355MPa (drip limit)

    2.3 General characteristics of the material

    For all concrete , these data are generated:

    cu= 3.5 (specific deformation last in )

    = 0.2 (Poisson coefficient)

    = 10-5K-1(linear coefficient of thermal expansion, in K-1)

    = 25 kN/m3(specific weight, in kN/m3)

    Elastic modulus cross section is obtained Gb=0.4E

    For these fittings the following data is general:

    uk= 7.5 % (specific deformation last, in %)

    = 0.3 (Poisson coefficient)

    = 10-5K-1(linear coefficient of thermal expansion, in K-1)

    = 78.5 kN/m3(specific weight, in kN/m3)

    3. LOADS CONSIDERED

    To determine the worst design situations for each structural element separately, were

    considered the following types of requests were considered:

    weight

    Weight path, sidewalk , guardrail and other utilities

    payload of convoys:

    - Class I - A13, S60

    - Class E - A30, V80

    - Grouping 1 or 1.a LM1, LM2, LM4

    thermal variations

    hitting security barriers

    loads that occur in the support elements of slopes or abutments:

    - Earth pushing

    - overload

    Seismic load Ag = 0.3g , TC = 1.0S bridges located south of Targoviste ( to km 44 ) and TC

    = 0.7s for the north

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    3/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    3/49

    4. Design assumptions

    For all structural elements, state of efforts and deformations were determined for each load

    considered. They were grouped using the principle of superposition effects , so you can check the

    quality criteria of adequate strength and ultimate limit state , serviceability limit state or fatigue limit

    state , where was the case. Next will be presented only the design situations that were conclusive

    for the structural elements analyzed.

    4.1 New superstructures

    Phase calculations were carried out considering the time modifications of the physico -

    mechanical properties of materials and the geometric calculation sections, which were sized by

    fittings quantities required and were optimized with metal or concrete sections.

    4.2 Old superstructures

    Calculations were carried out for state of efforts and deformations to estimate reserves of

    volumes of existing fittings, after which the effect of the designed works on the structural design was

    calculated, which resulted in the additional volumes of fittings or steel.

    4.3 Infrastructures

    If elevations in both elevations and the foundations, the worst group proved to be the

    earthquake, considering the final stage of the works. Regarding new works, they were consistently

    sized, and the old ones bearing capacity was examined in relation to new efforts and, where

    appropriate, consolidation building works were designed.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    4/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    4/49

    5. STRUCTURAL DESIGN

    This chapter will present structural dimensioning of the components of each bridge in part,

    designed to implement safe work and building structures to associated class for Section 2 km

    51+041 km 85+000:

    5.1 Bridge on DN71 over stream at km 51+540 ............................................................................. 5

    5.2 Bridge on DN71 over stream at km 55+787 ............................................................................. 9

    5.3 Bridge on DN71 over Valea Dracului at km 62+839 ............................................................... 13

    5.4 Bridge on DN71 over stream Bizdidel at km 63+894 .............................................................. 14

    5.5 Bridge on DN71 over river Ialomita at km 68+605 ........................................................... ....... 17

    5.7 Bridge on DN71 over river Ialomicioara at km 73+281 ........... ......................................... ....... 27

    5.8 Bridge on DN71 over Valea Titei at km 79+563 ..................................................................... 32

    5.9 Bridge on DN71 over Valea Gae at km 82+544 ..................................................................... 32

    5.10 Bridge on DN71 over railroad at km 82+135 ........................................................................ 385.11 Bridge on DN71 over river Ialomita at km 82+544 ................................................................ 42

    5.12 Bridge on DN71 over Valea Lupului at km 82+238 ............................................................... 46

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    5/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    5/49

    5.1 Bridge on DN71 over stream at km 51+540

    It has an opening of 21m and a total length of 28.50m. The superstructure consists of precast

    beams of 21.00m length and 1.03m height over which we pour Reinforced concrete plate over

    concrete slab. They form a carriageway of 7.80m and 1.40m wide sidewalks protected by guardrail

    H4b. Infrastructures are massive reinforced concrete abutments, with direct foundation.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    6/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    6/49

    5.1.1 The superstructure in the longitudinal direction

    Following the calculations made, the most solicited beam emerged as being the one on the

    edge so all further results will be presented only for this one:

    At the last limit state, the maximum bending moment is in the middle and has a value of

    3785 kN x m, resulting in a total 21 beams needed TBP15 (7 5) from S1860 (a moment

    capable of 3800kN x m)

    At the last limit state, the maximum bearing shear force is on the support and has a value of

    835 kN, resulting 10 stirrups with 2 branches in the support area at 15cm, 30cm

    respectively in the middle (with a shear force capable of 940 kN maximum.)

    At the service limit state , considering a pulling force of 190kN, the following resulted:

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    7/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    7/49

    TRANSFER

    Axial Moment CharacteristicsFiber

    Unified effort Conditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    -3612514

    -17430.3736 0.0505

    Above plate 0.000 0

    Above beam 1.013 < 2.456

    C.G. strands -20.378 > -24

    Below beam -22.558 > -24

    CVASIPEMANENT

    Axial Moment CharacteristicsFiber

    Unified effort Conditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    528721+306

    +364.5

    0.606 0.094

    Above plate -2.163 < 0

    Above beam -5.938 < 0

    C.G. strands -8.102 < 0

    Below beam -8.323 < 0

    CHARACTERISTIC GROUPING

    Moment CharacteristicsFiber

    Unifiedeffort Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    1261 0.606 0.094

    Above plate -7.870 > -30

    Above beam -9.228 > -30

    C.G. strands 1.159 < 3.684

    Below beam 2.217 < 3.684

    FREQUENT GROUPING

    Moment CharacteristicsFiber

    Unifiedeffort Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    775 0.606 0.094

    Above plate -5.667 < -1

    Above beam -7.958 < -1

    C.G. strands -2.416 < -1

    Below beam -1.851 < -1

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    8/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    8/49

    NON FREQUENT GROUPING

    Moment CharacteristicsFiber

    Unifiedeffort Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    1009 0.606 0.094

    Above plate -6.728

    Above beam -8.570

    C.G. strands -0.693 < 2.456

    Below beam -0.109 < 2.456

    5.1.2 Support bearings

    For the maximum calculated reaction of 835 kN , neoprene bearings type 5 are proposed, with

    dimensions of 200x300x30mm, the load capacity of 900kN and horizontal deformations up to

    14.4mm, respective 6 mobile with 200x300x41mm dimensions, bearing capacity of 900kN and

    horizontal deformations of 21.6mm.

    5.1.3 Infrastructures

    5.1.3.1 Joint elevation-foundation

    In the joint elevation foundation, the seismic grouping turned out to be the worst , with an

    axial force of compression of 4950 kN and a bending moment to the value of 12 775 kN xm ,

    resulting in a reinforcement with beams 22 BST 500S at 15 cm on all section edges.

    5.1.3.2 Verification of foundation footing

    For seismic group, which has been shown to be the worst, an oblique eccentric loading as follows

    was obtained:

    N = 8030 kN

    MB= 29630 kN x m

    ML= 29815 kN x m

    pef max= 535 kPa

    pconv

    = 485 + CB+ C

    D= 485 + 37 + 20 = 542 kPa

    Verification criteria: pef max< pconv535 < 542 is verified

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    9/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    9/49

    5.2 Bridge on DN71 over stream at km 55+787

    A new bridge is proposed with static scheme with simple support beams with an opening of

    10.50m and a total length of 15.95m. The superstructure consists of 17 precast beams of 11.00m in

    length and 52cm height over which we pour Reinforced concrete plate over concrete slab. They

    form a roadway of 7.80m and 1.40m wide sidewalks protected by guardrail H4b. Infrastructures are

    massive reinforced concrete abutments, with direct foundation.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    10/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    10/49

    5.2.1 The superstructure in the longitudinal direction

    Following the calculations made, the most solicited beam emerged as being the one on the

    edge so all further results will be presented only for this one:

    At the last limit state, the maximum bending moment is in the middle and has a value of

    1190 kN xm , resulting in a total 11 beams needed TBP15 (7 5) from S1860 At the last limit state, the maximum bearing shear force is on the support and has a value of

    275 kN, resulting 10 stirrups with 2 branches in the support area at 20cm , 30cm

    respectively in the middle

    At the service limit state , considering a pulling force of 170kN, the following resulted :

    TRANSFER

    Axial Moment CharacteristicsFiber

    Unified effort Conditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    -167642.5

    -198.70.1513 0.0038

    Above plate 0.000 0

    Above beam 2.561 < 2.657

    C.G. strands -15.357 > -27

    Below beam -18.270 > -27

    CVASIPEMANENT

    Axial Moment CharacteristicsFiber

    Unified effort Conditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    244155+25.5

    +84.5

    0.313 0.02044

    Above plate -1.110 < 0

    Above beam -10.276 < 0

    C.G. strands -8.003 < 0

    Below beam -7.634 < 0

    CHARACTERISTIC GROUPING

    Moment CharacteristicsFiber

    Unifiedeffort Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    435.6 0.313 0.02044

    Above plate -8.597 > -30

    Above beam -12.436 > -30

    C.G. strands -0.634 < 3.985

    Below beam 1.286 < 3.985

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    11/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    11/49

    FREQUENT GROUPING

    Moment CharacteristicsFiber

    Unifiedeffort Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    294.85 0.313 0.02044

    Above plate -6.178 < -1

    Above beam -11.738 < -1

    C.G. strands -3.015 < -1

    Below beam -1.596 < -1

    NON FREQUENT GROUPING

    Moment CharacteristicsFiber

    Unifiedeffort Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    348.48 0.313 0.02044

    Above plate-7.100

    Above beam -12.004

    C.G. strands -2.108 < 2.657

    Below beam -0.498 < 2.657

    5.2.2 Superstructure cross section

    StageMoment Shear force

    (kN x m) / m (kN) / m

    Cement 5.3 7.15

    CTP 4.6 7.6

    Utile 2.1 4.5

    SLU 16.2 26

    Thanks to the resulting very low efforts (both bending moment,

    and shear values negligible) the section will constructively

    reinforce.

    5.2.3 Support bearings

    For the maximum calculated reaction of 275 kN , neoprene bearings type 2 are proposed, with

    dimensions of 200x100x30mm , the load capacity of 300kN and horizontal deformations up to

    14.4mm ( enough to take over deformations from temperature).

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    12/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    12/49

    5.2.4 Verification of foundation footing

    For seismic group, which has been shown to be the worst, an oblique eccentric loading as

    follows was obtained:

    N = 3000 kN

    MB= 7678 kN x m

    ML= 1434 kN x m

    pef max= 474 kPa

    pconv= 485 + CB+ CD= 485 + 23 + 20 = 528 kPa

    Verification criteria : pef max< pconv474 < 528 is verified

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    13/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    13/49

    5.3 Bridge on DN71 over Valea Dracului at km 62+839

    The bridge was executed around 1966 and was rated at class E load , convoys A30 and V80

    according to STAS 3221-63. Later the bridge was widened symmetrically with each 1,00m. The total

    length of the bridge is 11,33m with an opening of 6,15m. Total width of the bridge is 11.20m , with a

    carriageway of 7,80m without sidewalks and guardrails. Bridge superstructure is made of a

    reinforced concrete slab and two perforated strips with a height of 0,52m and 7,60m length. Theworks designed have no significant changes in terms of structure or state resistance of structural

    efforts.

    Although the new work load resulting from intervention generated sectional efforts

    approximately 70 % higher in all structural elements , these increases are not significant, resulting in

    sections as reinforced constructively as like the other details or elements.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    14/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    14/49

    5.4 Bridge on DN71 over stream Bizdidel at km 63+894The total length of the bridge is 81.05m with 4 Openings of 17,30m. Total width of the bridge

    is 12.00m , with a carriageway of 8.40m and two sidewalks of 1,50m. Transversal slope of the

    bridge is only one way. Transversely, the superstructure consists of 10 perforated strips , length

    17,54m , height 0,80m with neoprene bearings and consoles cast of monolithic concrete pavement.

    Abutments are massive concrete inverse walls and piles are lamellar rods for bearing strips

    equipped with all the infrastructure being founded directly.

    It is proposed to change the superstructure with one comprises 10 precast beams with

    18.00m length and height of 72cm Reinforced concrete plate over concrete slab, to ensure a road of

    8.40m and 1.50m each with two sidewalks.

    5.4.1 The superstructure in the longitudinal direction

    Following the calculations made, the most solicited beam emerged as being the one on the

    edge so all further results will be presented only for this one:

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    15/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    15/49

    At the last limit state, the maximum bending moment is in the middle and has a value of

    2716 kN xm , resulting in a total 20 beams needed TBP15 (7 5) from S1860, which

    correspond to a capable moment of 2,840 kN xm

    At the last limit state, the maximum bearing shear force is on the support and has a value of

    697 kN, resulting 10 stirrups with 2 branches in the support area at 10cm in bearing zone

    (with a shear force of 956 kN capable ) 20/30cm respectively in the middle.

    At the service limit state , considering a pulling force of 205kN, the following resulted:

    TRANSFER

    Axial Moment CharacteristicsFiber

    Unified effort Conditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    -3680416

    -11680.411 0.033

    Above plate 0

    Above beam 0.406 < 2.247

    C.G. strands -15.704 > -21

    Below beam -17.31 > -21

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    16/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    16/49

    CVASIPEMANENT

    Axial Moment CharacteristicsFiber

    Unified effort Conditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    244 618+61.4+254.5

    0.611 0.0665

    Above plate -1.171 < 0

    Above beam -7.372 < 0C.G. strands -6.79 < 0

    Below beam -6.732 < 0

    CHARACTERISTIC GROUPING

    Moment CharacteristicsFiber

    Unifiedeffort Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    916.5 0.611 0.0665

    Above plate -7.096 > -21

    Above beam -10.817 > -21

    C.G. strands -0.209 < 3.37

    Below beam 0.848 < 3.37

    FREQUENT GROUPING

    Moment CharacteristicsFiber

    Unifiedeffort Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    566.8 0.611 0.0665

    Above plate -4.835 < -1

    Above beam -9.503 < -1

    C.G. strands -2.72 < -1

    Below beam -2.044 < -1

    NON FREQUENT GROUPING

    Moment CharacteristicsFiber

    Unifiedeffort Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    733.2 0.611 0.0665

    Above plate -5.911 > -21

    Above beam -10.128 > -21

    C.G. strands -1.525 < 2.247

    Below beam -0.668 < 2.247

    5.4.2 Support bearings

    For the maximum calculated reaction of 697 kN , neoprene bearings type 5 are proposed, with

    dimensions of 200x300x30mm, the load capacity of 900kN and horizontal deformations up to

    14.4mm, respective 6 mobile with 200x300x41mm dimensions, bearing capacity of 900kN and

    horizontal deformations of 21.6mm

    5.4.3 Infrastructures

    Among the total weight of the initial superstructure and the new one are differences of less

    than 5% , so there are no significant differences between the efforts status of substructure works

    designed before and after.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    17/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    17/49

    5.5 Bridge on DN71 over river Ialomita at km 68+605

    The total length of the bridge is 205.96m , with six openings of 31.85m. Total width of the

    bridge is 10.05m , with a carriageway of 7.80m , and one sidewalk upstream of 1.50m. Bridge

    superstructure consists of four prefabricated beams , prestressed to modular lengths of 31.88m and

    1.80m height.

    Its proposed to cast a Reinforced concrete plate over concrete slab ensuring the roadway7.80m and the upstream sidewalk 1.40m, resulting in a total width of 10.22m.

    Elevation

    5.5.1 Longitudinal superstructure

    Following the calculations made, the most solicited beam emerged as being the one on the

    edge (number 4) so all further results will be presented only for this one:

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    18/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    18/49

    EFFORT STATE AFTER REMOVAL OF ROAD ELEMENTS

    AxialMoment

    Geometriccharacteristics Fiber

    Unifiedeffort Conditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    4480 -14820.62070.64830.9348

    0.26750.28570.3692

    Above plate 0.000 0

    Above beam -7.821 < 2.657

    C.G. strands -10.3698 > -27

    Below beam -12.069 > -27

    CVASIPEMANENT

    Moment Geometriccharacteristics Fiber

    Unifiedeffort Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    30952085

    1.5601 1.1971

    Above plate -0.871 < 0

    Above beam -12.872 < 0

    C.G. strands -5.027 < 0

    Below beam -0.103 < 0

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    19/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    19/49

    CHARACTERISTIC GROUPING

    MomentGeometric

    characteristics Fiber

    Unifiedeffort Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    2120 1.5601 1.1971

    Above plate -1.742 > -30

    Above beam -13.394 > -30C.G. strands -3.663 < 3.985

    Below beam 2.824 < 3.985

    FREQUENT GROUPING

    MomentGeometric

    characteristics Fiber

    Unifiedeffort Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    1272 1.5601 1.1971

    Above plate -1.402 < -0.5

    Above beam -13.190 < -0.5

    C.G. strands -4.195 < -0.5

    Below beam 0.483 < -0.5

    NON FREQUENT GROUPING

    MomentGeometric

    characteristics Fiber

    Unifiedeffort Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    1696 1.5601 1.1971

    Above plate -1.579

    Above beam -13.297

    C.G. strands -3.918 < 2.657

    Below beam 2.335 < 2.657

    From the above tables it may be noted that the beams do not check in with the convoy

    calculation frequency grouping LM1, but with convoys A30 and V80. Consequently, the bridge was

    raised only at the bridges load class E, as is otherwise foreseen to proceed in Euronorms in terms

    of old structures.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    20/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    20/49

    5.5.2 Superstructure cross section

    StageMoment Shear force

    (kN x m) / m (kN) / m

    Concrete 24 20CTP 18 14Utile 65 168.3SLU 145 273.1

    At the last limit state, for taking the bending

    moment, reinforcement bars 16 BST 500S at 15cm are

    required to which correspond capable moment of 180 kN x

    m. Similarly, for taking up the shear force, it will be armed

    with stirrups 10 BST 500S at 50cm on both sides of the

    plate.

    5.5.3 Infrastructures

    Between the total weight of the initial superstructure and rehabilitated one, there are

    differences of around 17 % , so there are no significant differences between the status of efforts in

    infrastructure works before and after the designed ones.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    21/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    21/49

    5.6 Bridge on DN71 over railroad at km 69+500

    a new passage is proposed with static scheme of continuous beams of 40-60-40m

    respectively 40-50-50-40m. The cross-section is mixed , consisting of a metal deck consists of 2

    semi boxes height of 1.60m, with longitudinal and transverse supports and a concrete slab 25cm

    and is bracketed over the top of the base of the metal boxes , in order to achieve cross slope of 5%.

    Over concrete deck plate is made the carriageway , sidewalks and guardrails. We obtain a roadwayof 7.80m and 2 sidewalks of 1.40m which include spaces for mounting directional guardrails.

    Infrastructures are made of 6 lamellar piles and two massive abutments with indirect

    foundation on drilled piles with a large diameter 1.50m and length of 25.00m.

    5.6.1 Longitudinal superstructure

    Next will be presented diagrams of the bending moment and shear force equal to a unit load

    or winding moment and shearing for payloads:

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    22/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    22/49

    Bending moment diagrams of a force equal to unity

    Shear force diagrams of a force equal to unity

    The bending moment envelope system TS

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    23/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    23/49

    The bending moment envelope system UDL

    According to the calculation made, the marginal beam emerged as the most solicited one so

    that further results will be presented only for it in various sections from above (A-G) :

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    24/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    24/49

    5.6.1.1 Verification of bending moment

    Next will be presented values of bending moments and normal sections of stresses on the

    various stages of execution:

    Stage 1 - Weight metal frame, plate over concrete slab, concrete shrinkage

    Calculation section A B C D E F G

    Bending Moment [kN x m] 1725 -5280 3545 2175 -4000 2060 -4125Effort on superior concreteplate

    [N / mm2]Effort on superior metalbeam

    -59.1 180.9 -121.5 -74.5 137.1 -70.6 141.4

    Effort on inferior metalbeam

    32.9 -100.7 67.6 41.5 -76.3 39.3 -78.7

    Stage 2 - Elimination towers, concrete contraction phase 2, pathway - pavement - guardrail

    Calculation section A B C D E F G

    Bending Moment [kN x m] 1725 -5276 3543 2175 -4000 2060 -4125

    Effort on superior concrete

    plate

    [N / mm2]

    -0.9 2.7 -1.8 -1.1 2.1 -1.1 2.1Effort on superior metalbeam

    -12.1 36.9 -24.8 -15.2 28.0 -14.4 28.9

    Effort on inferior metalbeam

    22.4 -68.6 46.1 28.3 -52.0 26.8 -53.6

    Stage 3 - Traffic Loads

    Calculation section A B C D E F G

    Bending Moment [kN x m] 6433 -7705 8286 6395 -6200 6760 -6520

    Effort on superior concreteplate

    [N / mm2]

    -3.5 4.2 -4.5 -3.5 3.4 -3.7 3.6

    Effort on superior metalbeam -11.1 13.3 -14.3 -11.0 10.7 -11.6 11.2

    Effort on inferior metalbeam

    76.2 -91.2 98.1 75.7 -73.4 80.0 -77.2

    Calculation section A B C D E F G Verification

    Effort on superiorconcrete plate

    [N /mm2]

    -6 9 -9 -6 7 -6 8Comp

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    25/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    25/49

    5.6.1.2 Verification of shear force

    Final stage efforts

    Calculation section R1 R2 R3 R4 R5

    Shear force calculation (VEd) [kN] 1640 2890 1730 2525 2525

    Capable shear force (VRd) [kN] 4330 8660 4330 6490 6490

    0.4 0.3 0.4 0.4 0.4

    Since the dimensionless factor = VEd/ VRdis always kept below 0.5 its no longer necessary to

    check the loss of stability of the heart by buckling or bending moment in combination with shear

    force.

    5.6.2 Superstructure cross section

    StageMoment Shear force(kN x m) / m (kN) / m

    Cement 10.8 11.15CTP 7.7 10Utile 5.23 5SLU 32 35.3

    For taking the bending moment reinforcement bars 12 BST

    500S at 20cm are required.

    Regarding shear force , given the very small efforts

    resulted, the section will be constructively reinforced.

    5.6.3 Support bearingsFor the maximum calculated reaction on abutments of 1637 kN (R1),respectively 1730 kN

    (R3), neoprene mobile bearings type 14 are proposed, with dimensions of 300x500x81mm, the

    load capacity of 2250kN and horizontal deformations up to 49.5mm..

    For the maximum calculated reaction on piles of 5035 kN (R2), 4540 kN (R4) respective 4605

    kN (R5), neoprene fixed bearings type 21 are proposed, with dimensions of 550x650x54mm, the

    load capacity of 5300kN and horizontal deformations up to 29.7mm.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    26/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    26/49

    5.6.4 Expansion joints

    Table displacement results in joints

    Section Abutment Pile

    Temperature [cm] 2.88 17.28

    Seismic [cm] 3.55 15.33

    0.5xSeism+0.5x Temperature [cm] 3.22 16.31

    Adopted [cm] 10.00 20.00

    5.6.5 Substructure elevations

    The calculation resulted that the most solicited element of the substructure is pile P4.

    Therefore only these results will be presented. In group seismic bending moment is

    maximum at joint elevation - foundation and has 15830 kN x m with a corresponding axial

    force 6460 kN, resulting in a reinforcement bar 32 BST 500S at 10 cm (corresponding to

    capable moment of 16300 kN x m with a corresponding axial force 6390 kN).

    In the event of train impactagainst the protective gear block

    resulted a pile bending moment at the

    base of a value of 10236 kN xm. This

    resulted in a vertical reinforcement

    bars 20 BST 500S 15 cm around

    the clock.

    For uptaking the shear force, a

    constructive reinforcement is

    sufficient, as the concrete can take it

    up almost fully (VRdc=3630 kN).

    5.6.6 Piles Verification

    Calculation efforts:

    Nr. crt. Calculation hypothesis sectional Effort

    1. Maximum axial force Nmax = 5830 kN, Nmin=-475 kN

    2. Maximum bending moment Mmax = 4060 kN x m, Ncor= 560 kN

    3. The maximum shear force Vmax = 580 kN

    5.6.6.1 For piles 1500mm with 25.00m sheet with a slab foundation level of 2.00m , to

    obtain maximum lifting capacity of 6820 kN under compression (compared to 5830 kN maximumeffort ) , composed of 3275 kN and peak pressure of 3545 kN of mantle friction. Tensile load bearing

    capacity of 1470 kN is calculated (compared to maximum tractive effort of 475 kN of the pilot).

    5.6.6.2 For reinforcement 32 bars 28BST 500S were able to obtain a moment 4480 kN xm

    (compared to 4060 when computing kN xm ) with an axial force of 485 kN corresponding capable

    (compared to axial force of 560kN computing).

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    27/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    27/49

    5.6.6.3 For Spiral reinforcement 10 BST 500S to step 10cm to obtain a shear force of 1720

    kN capable ( versus shear calculation with a value of 580 kN). To mention that after the first 10.00m

    , up to 20cm can be increased.

    5.7 Bridge on DN71 over river Ialomicioara la km 73+281

    It is proposed to change the superstructure keeping the static scheme of the continuous beamwith openings of 18.40m - 24.00m, 18.40m. Cross section consists of three reinforced concrete

    beams with thick 55cm and 90cm in the bearing field , with heights of 2.20m , 2.30m respectively ,

    with a plate of variable thickness averaging 35cm. Over the concrete deck plate is the carriageway,

    sidewalks and guardrails . We obtain a roadway of 8.40m and sidewalks of 1.40m which include the

    space for mounting the directional guardrails.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    28/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    28/49

    5.7.1 Longitudinal superstructure

    Next will be presented diagrams of the bending moment and shear force equal to a unit load

    or winding and shearing moment for payloads:

    Bending moment diagrams of a force equal to unity

    Shear force diagrams of a force equal to unity

    The bending moment envelope system TS

    Enveloping shear system TS

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    29/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    29/49

    The bending moment envelope system UDL + people

    Enveloping UDL shear system + people

    According to the calculation made, the marginal beam emerged as the most solicited one so

    that further results will be presented only for it in various sections from above (R1, C1, R2, C2):

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    30/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    30/49

    5.7.1.1 Verification of bending moment

    Next will be presented values of bending moments and normal sections of stresses:

    Bending moments [kNm]

    StageSection

    C1 R1 C2

    Beam 604.8 -1244.7 699.3

    Plate + braces 828.8 -1705.7 958.3

    CTP 414.4 -852.9 479.2

    TS 2457.5 -1491.6 2607.5

    UDL + people 1076.2 -1581.1 1231.7

    SLU 7265.3 -9282.5 8067.5

    To receive bending moments, reinforcements were provided as follows:Calculation section C1 R1 C2

    Areas necessary reinforcement(mm2) 8000 11175 8890

    Reinforcement beams BST500S 1032 2425 1232

    Capable moment [kNm] 7303 9785 8759

    5.7.1.2 Verification at shear force

    Shear force [kN]

    Stage

    Section

    R1 C1 R2 C2

    Beam 180.9 86.4 324.0 0.0

    Plate + braces 180.9 86.4 324.0 0.0

    CTP 180.9 86.4 324.0 0.0

    TS 671.8 387.2 688.4 329.1

    UDL + people 257.7 137.7 399.8 115.4

    SLU 1987.5 1058.5 2781.3 600.1

    Withstanding shear forces, the following reinforcements were provided as follows :

    Calculationsection

    R1 C1 R2 C2

    Reinforcementstirrups

    BST 500S

    2 stirrups12 at 20cm

    2 stirrups10 at 30cm

    2 stirrups12 at 15cm

    It is notnecessary

    Capable sheerforce[kN]

    2375 1090 3165 657

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    31/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    31/49

    5.7.2 Cross section superstructure

    Console platePlate between

    beams

    StageMoment

    Shearforce

    MomentShearforce

    kN x m kN kN x m kNConcrete 122.4 76.5 42.9 52CTP 96.26 50.4 14.1 17.7Utile 242 200 165 100SLU 621.9 441.3 300 228.3

    To attain the bending moment on the console, revealed the area of reinforcement required tobe 4806mm2. Reinforcement with beams was adopted 16 BST 500S at 15cm, an effective area of

    4825mm2.

    To attain the bending moment between beams, revealed the area of reinforcement required to

    be 2267mm2. Reinforcement with beams was adopted 16 BST 500S at 15cm, an effective area of

    4825mm2.

    Due to the large thickness of the slab is not necessary to retrieve vertical shear reinforcement

    , concrete strength is sufficient for taking such efforts.

    5.7.3 Support bearings

    For the maximum calculated reaction on abutments of 1987.5 kN (R1), neoprene mobile

    bearings type 18 are proposed, with dimensions of 400x600x110mm, the load capacity of 3600kN

    and horizontal deformations up to 69.3mm.

    For the maximum calculated reaction on piles of 3545 kN (R2), , neoprene fixed bearings type

    17 are proposed, with dimensions of 400x600x52mm, the load capacity of 3600kN and horizontal

    deformations up to 29.7mm, respectively neoprene mobile bearings type 18 are proposed, with

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    32/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    32/49

    dimensions of 400x600x110mm, the load capacity of 3600kN and horizontal deformations up to

    69.3mm.

    5.7.4 Infrastructures

    In terms of weights and masses, significant differences between the old and the new

    superstructure dont exist. Taking into account the fact that there is no intervention on resistanceelements of the infrastructure , it follows that their verification is not required.

    5.8 Bridge on DN71 over Valea Titei at km 79+563

    Not applicable because only the road elements and exterior surfaces degraded are being upgraded,

    resistance structures are untouched.

    5.9 Bridge on DN71 over Valea Gae at km 82+544

    The bridge was dimensioned to Class E load ( convoys A30 and V80 ) ; according to STAS

    3221-63. The total length of the bridge is 23,30m with a single opening of 17,30m. The total width is10,40m with a carriageway of 7,90m and 2 sidewalks of 1,00m, now fully covered. Bridgesuperstructure consists of four monobloc prestressed precast beams with collaboration betweenbeams achieved by the plate and three prestressed struts. Propping the superstructure is made withmetal bearings . Abutments are founded directly and have massive concrete elevations.

    It is proposed to demolish the slab between beams, of consoles and struts for reuse of theexisting beams. 4 existing beams are remounted with a new beam with the same geometricalcharacteristics. The beams will thus have to 2.05m between axes on the new neoprene bearings. Inaddition, the execution is planned of tile Reinforced concrete plate over concrete slab allowing aroad of 8.40m and sidewalks 1.40m. To get to a better state of efforts in the final phase , the platewill be poured in 2 stages.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    33/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    33/49

    5.9.1 Longitudinal superstructure

    5.9.1.1 Prefabricated new beam

    At the last limit state, the maximum bending moment is in the middle and has a value of

    5840 kN xm , resulting in a total 26 beams needed TBP15 (7 5) from S1860 (with a

    capable moment 6130 kN x m).

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    34/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    34/49

    At the last limit state, the maximum bearing shear force is on the support and has a value of

    1197 kN, resulting 14 stirrups with 2 branches in the support area ( value of shear force

    capable of 1436 kN) at 20cm , 30cm respectively in the middle.

    At the service limit state , considering a pulling force of 160kN, the following resulted:

    TRANSFER

    Axial Moment CharacteristicsFiber

    Stress Conditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    -4002387

    -19750.3756 0.0674

    Above plate 0.000 0

    Above beam 1.369 < 2.456

    C.G. strands -21.143 > -24

    Below beam -23.236 > -24

    CVASIPEMANENT

    Axial Moment Characteristics

    Fiber

    Stress Conditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    596.8631

    +1070+590

    1.212 0.204

    Above plate -2.971 < 0

    Above beam -2.960 < 0

    C.G. strands -8.276 < 0

    Below beam -9.242 < 0

    CHARACTERISTIC GROUPING

    Moment CharacteristicsFiber

    Stress Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    1865 1.212 0.204

    Above plate -7.636 > -26.67

    Above beam -3.252 > -26.67C.G. strands 2.535 < 3.685

    Below beam 3.587 < 3.685

    FREQUENT GROUPING

    Moment CharacteristicsFiber

    Stress Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    1195 1.212 0.204

    Above plate -5.862 < -1

    Above beam -3.141 < -1

    C.G. strands -1.577 < -1

    Below beam -1.293 < -1

    INFREQUENT GROUPING

    Moment CharacteristicsFiber

    Stress Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    1495 1.212 0.204

    Above plate -6.703

    Above beam -3.193

    C.G. strands 0.372 < 2.456

    Below beam 1.021 < 2.456

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    35/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    35/49

    5.9.1.2 Prefabricated existing beams

    The calculation made, the most solicited emerged as being beam 7 so that further results willbe presented only for it. All checks were made considering appropriate reinforcement strands

    corresponding to class I of fissuring from the moment of execution of the structure ( 26 + 2 ) TBP

    strands Type 12 (7 4 ) of S1860.

    At the last limit state, the maximum bending moment is in the middle and has a value of

    4960 kN x m, covered by the capable moment given by the beam in collaboration with the

    thicker plate calculated at 5685 kN x m

    At the last limit state , the maximum bearing shear force is 1047 kN , covered by the capable

    shear force with value 1457 kN , corresponding to stirrup reinforcement 8 from PC52 with 2

    branches in the support area at 5cm , 10,20cm respectively towards the middle.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    36/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    36/49

    At the service limit state , considering a pulling force of 109kN, the following resulted

    AFTER REMOVAL OF PLATE AND ROAD STRUCTURES

    Axial Moment CharacteristicsFiber

    Stress Conditions

    [kN] [kN x m] A [m2

    ] I [m4

    ] [N/mm2

    ] [N/mm2

    ]

    -3590 -1435 0.3756 0.0675

    Above plate 0.000 0

    Above beam -0.127 < 2.247

    C.G. strands -15.906 > -21

    Below beam -17.854 > -21

    CVASIPEMANENT

    Moment CharacteristicsFiber

    Stress Conditions

    [kN x m] A [m2

    ] I [m4

    ] [N/mm2

    ] [N/mm2

    ]

    1897 1.213 0.205

    Above plate -2.364 < 0

    Above beam -5.933 < 0

    C.G. strands -7.755 < 0

    Below beam -8.068 < 0

    CHARACTERISTIC GROUPING

    Moment CharacteristicsFiber

    Stress Conditions

    [kN x m] A [m

    2

    ] I [m

    4

    ] [N/mm

    2

    ] [N/mm

    2

    ]

    1415 1.213 0.205

    Above plate -5.310 > -21

    Above beam -6.119 > -21

    C.G. strands -0.875 < 3.370

    Below beam 0.027 < 3.370

    FREQUENT GROUPING

    Moment CharacteristicsFiber

    Stress Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    1061 1.213 0.205

    Above plate -4.574 < -1

    Above beam -6.073 < -1

    C.G. strands -2.595 < -1

    Below beam -1.997 < -1

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    37/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    37/49

    INFREQUENT GROUPING

    Moment CharacteristicsFiber

    Stress Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    1132 1.213 0.205

    Above plate -4.574

    Above beam -6.073

    C.G. strands -2.251 < 2.247

    Below beam -1.592 < 2.247

    From the above tables it may be noted that the beams do not check in with the convoy

    calculation frequency grouping LM1, but with convoys A30 and V80. Consequently, the bridge was

    raised only at the bridges load class E, as is otherwise foreseen to proceed in Euronorms in terms

    of old structures.

    5.9.2 Support bearings

    For maximum calculated reaction of 1197 kN , propose neoprene bearings, fixed type9 respectively , with dimensions of 200x400x30mm , the load capacity of 1200kN and horizontal

    deformation of 14.4mm, respectively tip 10 mobile, with dimensions of 200x400x63mm, the load

    capacity of 1200kN and horizontal deformation of 36mm.

    5.9.3 Verification of foundation footing

    For seismic group , which has been shown to be the worst, an oblique eccentric loading as

    follows was obtained:

    N = 6420 kN

    MB= 11000 kN x m

    ML= 10995 kN x m

    pef max= 513 kPa

    pconv= 485 + CB+ CD= 485 + 23 + 20 = 528 kPa

    Verification criteria: pef max< pconv513 < 528 to verify

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    38/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    38/49

    5.10 Overpass on DN71 over railroad at km 82+135

    a new bridge is proposes static scheme by a simply supported beams with an opening of

    11.50m and a total length of 17.10m. The superstructure consists of 17 precast beams of 12.00m in

    length and 52cm height we pour Reinforced concrete plate over concrete slab. They form a

    carriageway of 7.80m and two sidewalks 1.40m width protected by guardrail H4b. Infrastructures

    are massive reinforced concrete abutment, with direct foundation.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    39/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    39/49

    5.10.1 Longitudinal superstructure

    Following the calculations made, the most solicited beam emerged as being the one on the

    edge so all further results will be presented only for this one:

    At the last limit state, the maximum bending moment is in the middle and has a value of

    1620 kN xm , resulting in a total 16 beams needed TBP15 (7 5) from S1860 At the last limit state, the maximum bearing shear force is on the support and has a value of

    307 kN, resulting 10 stirrups with 2 branches in the support area at 20cm , 30cm

    respectively in the middle

    At the service limit state , considering a pulling force of 170kN, the following resulted:

    TRANSFER

    Axial Moment CharacteristicsFiber

    Stress Conditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    -243762.5

    -242.30.1513 0.0038

    Above plate 0.000 0

    Above beam 0.075 < 2.657

    C.G. strands -19.717 > -27

    Below beam -23.894 > -27

    CVASIPEMANENT

    Axial Moment CharacteristicsFiber

    Stress Conditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    380

    220

    +37.5

    +123.8

    0.313 0.02044

    Above plate -1.566 < 0

    Above beam -18.131 < 0

    C.G. strands -10.354 < 0

    Below beam -8.713 < 0

    CHARACTERISTIC GROUPINGS

    Moment CharacteristicsFiber

    Stress Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    557.6 0.313 0.02044

    Above plate -11.137 > -30

    Above beam -20.934 > -30

    C.G. strands -1.533 < 3.985

    Below beam 2.562 < 3.985

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    40/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    40/49

    FREQUENT GROUPINGS

    Moment CharacteristicsFiber

    Stress Conditions

    [kN x m] A [m2

    ] I [m4

    ] [N/mm2

    ] [N/mm2

    ]

    372.7 0.313 0.02044

    Above plate -7.964 < -1

    Above beam -20.004 < -1

    C.G. strands -4.458 < -1

    Below beam -1.177 < -1

    INFREQUENT GROUPINGS

    Moment CharacteristicsFiber

    Stress Conditions

    [kN x m] A [m

    2

    ] I [m

    4

    ] [N/mm

    2

    ] [N/mm

    2

    ]

    446.1 0.313 0.02044

    Above plate -9.223

    Above beam -20.373

    C.G. strands -3.297 < 2.657

    Below beam 0.307 < 2.657

    5.10.2 Cross section superstructure

    Stage

    Moment Shear force

    (kN x m) / m (kN) / m

    Concrete 5.3 7.15

    CTP 4.6 7.6

    Utile 2.1 4.5

    SLU 16.2 26

    Thanks to the efforts of very low results ( both bending moment ,

    and shear values negligible ) will be armed constructively.

    5.10.3 Support bearings

    For the maximum calculated reaction of 297 kN , neoprene bearings type 2 are proposed, with

    dimensions of 200x100x30mm , the load capacity of 300kN and horizontal deformations up to

    14.4mm ( enough to take over deformations from temperature.)

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    41/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    41/49

    5.10.4 Verification of foundation footing

    For seismic group , which has been shown to be the worst, an oblique eccentric loading as follows

    was obtained:

    N = 3000 kN

    MB= 7678 kN x m

    ML= 1434 kN x m

    pef max= 474 kPa

    pconv= 485 + CB+ CD= 485 + 23 + 20 = 528 kPa

    Verification criteria: pef max< pconv474 < 528 to verify

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    42/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    42/49

    5.11 Bridge over DN71 over river Ialomita at km 82+544

    The total length of the bridge is 141.20m , 4 openings of 28.50m. Total width of the bridge is

    12.10m , with a carriageway of 8.80m , and two sidewalks 1.40m. Bridge superstructure consists of

    five precast beams , prestressed to modular lengths of 29.00m and 1.80m height . It is proposed to

    change the superstructure on the last opening.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    43/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    43/49

    5.11.1 Longitudinal superstructure

    After the calculations made, the most solicited beam emerged as being the one on the edge

    so all further results will be presented only for this one:

    EFFORT STATE AT TRANSFER

    AxialMoment

    Geometriccalculations Fiber

    StressConditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    -72031645-6003

    0.646 0.2857

    Above plate 0.000 0Above beam 1.336 < 2.657

    C.G. strands -22.593 > -27

    Below beam -24.379 > -27

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    44/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    44/49

    CVASIPEMANENT

    Axial MomentGeometric

    calculations FiberStress

    Conditions[kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    815369316571168

    1.5601 1.1971

    Above plate -1.942 < 0Above beam -9.344 < 0

    C.G. strands -6.051 < 0

    Below beam -5.805 < 0

    CHARACTERISTIC GROUPING

    MomentGeometric

    calculations FiberStress

    Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    3269 1.5601 1.1971

    Above plate -4.786 > -30

    Above beam -10.507 > -30

    C.G. strands 0.825 < 3.985

    Below beam 1.671 < 3.985

    FREQUENT GROUPING

    MomentGeometric

    calculations FiberStress

    Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    1922 1.5601 1.1971

    Above plate -3.674 < -1

    Above beam -10.052 < -1

    C.G. strands -1.862 < -1

    Below beam -1.251 < -1

    INFREQUENT GROUPING

    MomentGeometric

    calculations FiberStress

    Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    2615 1.5601 1.1971

    Above plate -4.217

    Above beam -10.274

    C.G. strands -0.55 < 2.657

    Below beam 0.176 < 2.657

    From the above tables it may be noted that the beams do not check in with the convoy

    calculation frequency grouping LM1, but with convoys A30 and V80. Consequently, the bridge was

    raised only at the bridges load class E, as is otherwise foreseen to proceed in Euronorms in terms

    of old structures.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    45/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    45/49

    5.11.2 Superstructure cross section

    StageMoment Shear Force

    (kN x m) / m (kN) / m

    Cement 24 20CTP 18 14Utile 65 168.3SLU 145 273.1

    At the last limit state, for taking the bending moment

    resulted that reinforcement bars 16 BST 500S at 15cm

    are required to which correspond a capable moment of 180

    kN x m . Similarly, regarding shear force, it will be armed

    with stirrups 10 BST 500S at 50cm on both sides of the

    plate.

    5.11.3 Infrastructures

    Between the total weight of the initial superstructure and rehabilitated one, there are

    differences of around 12 % , so there are no significant differences between the status of efforts in

    infrastructure works before and after the designed ones.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    46/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    46/49

    5.12 Bridge on DN71 over Valea Lupului at km 82+238

    The total length of the bridge is 52.50m 3 simply supported openings of 15,00m. Total width of

    the bridge is 12.20m , with a carriageway of 8.60m and two sidewalks of 1,50m. Transversal slope

    of the bridge is only one way. Transversely the superstructure comprises 10 precast beams , length

    15,00m , height 0,72m with neoprene bearings and sidewalk consoles cast of monolithic concrete.

    Abutments are massive concrete turned walls and lamellar piles with rods for bearing strips, all the

    infrastructure being founded directly.

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    47/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    47/49

    5.12.1 Longitudinal superstructure

    After the calculations made, the most solicited beam emerged as being the one on the edge

    so all further results will be presented only for this one:

    At the last limit state, the maximum bending moment is in the middle and has a value of

    2716 kN x m, resulting in a total 20 beams needed TBP15 (7 5) from S1860 (a moment

    capable of 2840 kN x m)

    At the last limit state, the maximum bearing shear force is on the support and has a value of

    697 kN, resulting 10 stirrups with 2 branches in the support area at 10cm, 30cm

    respectively in the middle (with a shear force capable of 956 kN maximum.)

    At the service limit state , considering a pulling force of 205kN, the following resulted:

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    48/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    48/49

    TRANSFER

    Axial Moment CharacteristicsFiber

    Stress Conditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    -3680

    416

    -1168 0.411 0.033

    Above plate 0

    Above beam 0.406 < 2.247

    C.G. strands -15.704 > -21Below beam -17.31 > -21

    CVASIPEMANENT

    Axial Moment CharacteristicsFiber

    Stress Conditions

    [kN] [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    244618

    +61.4+254.5

    0.611 0.0665

    Above plate -1.171 < 0

    Above beam -7.372 < 0

    C.G. strands -6.79 < 0

    Below beam -6.732 < 0

    CHARACTERISTIC GROUPING

    Moment CharacteristicsFiber

    Stress Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    916.5 0.611 0.0665

    Above plate -7.096 > -21

    Above beam -10.817 > -21

    C.G. strands -0.209 < 3.37

    Below beam 0.848 < 3.37

    FREQUENT GROUPING

    Moment CharacteristicsFiber

    Stress Conditions

    [kN x m] A [m2

    ] I [m4

    ] [N/mm2

    ] [N/mm2

    ]

    566.8 0.611 0.0665

    Above plate -4.835 < -1

    Above beam -9.503 < -1

    C.G. strands -2.72 < -1

    Below beam -2.044 < -1

    INFREQUENT GROUPING

    Moment CharacteristicsFiber

    Stress Conditions

    [kN x m] A [m2] I [m4] [N/mm2] [N/mm2]

    733.2 0.611 0.0665

    Above plate -5.911 > -21

    Above beam -10.128 > -21

    C.G. strands -1.525 < 2.247

    Below beam -0.668 < 2.247

    5.12.2 Bearing structures

  • 7/25/2019 Breviar Structuri DN71 - Sector 2

    49/49

    Revizuire/Actualizare Studiu de Fezabilitate pentru Modernizare DN71 Baldana-Targoviste-Sinaia

    km 0+000 - km 44+130 largire la 4 benzi si km 51+041 km 109+905 drum la 2 benziBreviar de calcul structuri Sector 2

    For the maximum calculated reaction of 651 kN , neoprene bearings type 5 are proposed, with

    dimensions of 200x300x30mm, the load capacity of 900kN and horizontal deformations up to

    14.4mm, respective 6 mobile with 200x300x41mm dimensions, bearing capacity of 900kN and

    horizontal deformations of 21.6mm.

    5.12.3 InfrastructuresAmong the total weight of the initial superstructure and the new one are differences of less

    than 5% , so there are no significant differences between the efforts status of substructure works

    designed before and after.

    Verified, Drafted,

    ing. Strambu Stefan ing. Urdareanu Vlad


Recommended