FILAC™ 3000 OEM THERMOMETRY Market-Leading Technology Choosing the Filac™ 3000 OEM thermometry option for your multiparameter device will give you access to the resources you need to successfully satisfy the demands of the market. Our Filac™ 3000 OEM thermometry offerings are RoHS compliant, meet IPC 610 standards, and are manufactured in FDA regulated / ISO 13485 registered facilities. Easy Integration The Filac™ 3000 OEM thermometry offerings have been designed specifically for OEM integration. Our development kit contains all of the information needed to facilitate integration of the Filac™ 3000 thermometer technology into your multiparameter device. Developers also will be provided other necessary tools, including mechanical models, drawings, communication protocols, interface documentation, and component samples. Market Acceptance The Filac™ 3000 thermometers and probes are known for reliability, durability, and accuracy. Many companies integrate our technology in their multiparameter units. Infection Control The color coded Filac™ 3000 isolation chambers are also available for integration to provide a simple, yet effective, means of preventing cross-contamination between oral and rectal probes. The Filac™ 3000 OEM component auto-senses an attached probe and adjusts the measurement technique accordingly for an oral/axillary or rectal reading. Technical Support Your satisfaction and the success of your multiparameter device occupy the core of our focus. Should you have any customer support inquiries related to our components or development kit, our experienced team of engineers and sales associates will be at your service for technical and ordering support. Technology for Integration into Multiparameter Devices
Transcript
Page 1: Brochure: Filac™ 3000 OEM Thermometry

FILAC™ 3000OEM THERMOMETRY

Market-Leading Technology Choosing the Filac™ 3000 OEM thermometry option for your multiparameter device will give you access to the resources you need to successfully satisfy the demands of the market. Our Filac™ 3000 OEM thermometry offerings are RoHS compliant, meet IPC 610 standards, and are manufactured in FDA regulated / ISO 13485 registered facilities.

Easy IntegrationThe Filac™ 3000 OEM thermometry offerings have been designed specifically for OEM integration. Our development kit contains all of the information needed to facilitate integration of the Filac™ 3000 thermometer technology into your multiparameter device. Developers also will be provided other necessary tools, including mechanical models, drawings, communication protocols, interface documentation, and component samples.

Market AcceptanceThe Filac™ 3000 thermometers and probes are known for reliability, durability, and accuracy. Many companies integrate our technology in their multiparameter units.

Infection ControlThe color coded Filac™ 3000 isolation chambers are also available for integration to provide a simple, yet effective, means of preventing cross-contamination between oral and rectal probes. The Filac™ 3000 OEM component auto-senses an attached probe and adjusts the measurement technique accordingly for an oral/axillary or rectal reading.

Technical SupportYour satisfaction and the success of your multiparameter device occupy the core of our focus. Should you have any customer support inquiries related to our components or development kit, our experienced team of engineers and sales associates will be at your service for technical and ordering support.

Technology forIntegration into Multiparameter Devices

Page 2: Brochure: Filac™ 3000 OEM Thermometry

Product Specifications ACCURACY

• Quick Mode (Oral): +/-0.3O C (+/-0.6O F) • Standard Mode (Axillary/Rectal): +/-0.1O C (+/-0.2O F) • Direct Mode: +/-0.1O C (+/-0.2O F)

MEASUREMENT RESPONSE TIME

• Quick Mode (Oral): 3-5 seconds• Standard Mode (Oral): 6-10 seconds• Auxillary: 8-12 seconds• Rectal: 10-14 seconds • Direct Mode: 60-120 seconds

AMBIENT OPERATING RANGE

• 10–40O C (50–104OF) at 10–95% RH

TEMPERATURE RANGE

• 30–43.0O C (86.0–109OF)

STORAGE TEMPERATURE RANGE

• -25–55O C (-13–131OF) at 95% RH (noncondensing)

VOLTAGE REQUIREMENTS

• 5–6 volts

For additional information contact your Cardinal Health sales representative at [email protected] or visit cardinalhealth.com/OEM-medical.

ISOLATION CHAMBER

© 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and Filac are trademarks or registered trademarks of Cardinal Health and may be registered in the US and/or in other countries. 03/2018 - H9837 - WF#753808

15 Hampshire StreetMansfield, MA 02048

800.962.9888508.261.8000

Order Information

Code Description Ship Case

500062 Filac™ 3000 OEM PCB 80

500026 Filac™ 3000 Oral Probe 4 ft. 1

500027 Filac™ 3000 Oral Probe 9 ft. 1

500028 Filac™ 3000 Oral Isolation Chamber 1

500036 Filac™ 3000 Rectal Probe 4 ft. 1

500037 Filac™ 3000 Rectal Probe 9 ft. 1

500038 Filac™ 3000 Rectal Isolation Chamber 1

502000 Filac™ 3000 Probe Covers 2000

500099 Filac™ 3000 Calibration Plug 1

Quick Predictive Measurement Technology

ORAL PROBE


Recommended