Micro Drill- and Shaver System Micro Drill & Shaver System GK_E_1 Micro Drill and Shaver System DT55-EX One for all... ...was the idea behind the development of this drill system, particularly re- garding the use in ENT-surgery. Both the material and the console should be capable of mastering a range of challenges at any given time, whether there be a mastoidectomy with the usual otology handpiece, or the use of a shaver in sinus surgery. Importance was also placed on the aspect of a construction suited to mee- ting the highest quality demands for both the patient and the user, whilst keeping the costs within an acceptable boundary. The result of these efforts is a product whose extensive range of accessories make it possible to pro- vide a comprehensive scale of usage, whilst offering exceptional value for money. Simplicity... ...is the keyword in both installation and usage. However, the choice of possibilities and the range of settings are many and versatile. The second motor socket clearly reduces the cumbersome need for hand- piece changes. The menu has been designed to be self-explanatory, preferred set- tings can be saved using the program selection keys. The integrated pump is not only an optically pleasing solution, it makes tube chan- ging child‘s play. From start to finish... ...everything from one source. Regardless of whether you require rotary in- struments for your drill handpiece, blades for a shaver or even saw-blades, dermatome blades, rinsing hoses or a storage container - all no problem. It is not thrown together on a whim, but carefully selected and tuned to harmonise with each other. The weakest link is the crucial factor, and thus the quality of the accessories is a significant contribution to the complete end result. Art. No. DT-55 EX Control Unit Voltage: 115/230V, 50-60Hz Power: 160 W Speed: 500 - 40.000 rpm Connections: 2 x motor, 1 x foot pedal Dimensions: 290 x 260 x 140 mm Weight: 4.5 kg Integrated Pump Rollers: 8 Capacity: max. 3l / h Regulation: 10% steps Micro Motor Speed: 500 - 40.000 rpm Torque: 4/10 Ncm Cooling: air cooled Drill- and Shaver-System, consisting of: 2 Main control unit 2 Micro motor (+ rack) 2 Foot pedal 2 1 liter irrigation bottle (0,9% NaCl-solution, sterile) 2 Bottle holder 2 Tubing set (3 m, sterile)
Transcript

Micro Drill- and Shaver System

Micro Drill & Shaver System

GK_E_1

Micro Drill and Shaver System DT55-EX

One for all... ...was the idea behind the development of this drill system, particularly re-garding the use in ENT-surgery. Both the material and the console should be capable of mastering a range of challenges at any given time, whether there be a mastoidectomy with the usual otology handpiece, or the use of a shaver in sinus surgery. Importance was also placed on the aspect of a construction suited to mee-ting the highest quality demands for both the patient and the user, whilst keeping the costs within an acceptable boundary. The result of these efforts is a product whose extensive range of accessories make it possible to pro-vide a comprehensive scale of usage, whilst offering exceptional value for money.

Simplicity...

...is the keyword in both installation and usage. However, the choice of possibilities and the range of settings are many and versatile. The second motor socket clearly reduces the cumbersome need for hand-piece changes.

The menu has been designed to be self-explanatory, preferred set-tings can be saved using the program selection keys. The integrated pump is not only an optically pleasing solution, it makes tube chan-ging child‘s play.

From start to fi nish...

...everything from one source. Regardless of whether you require rotary in-struments for your drill handpiece, blades for a shaver or even saw-blades, dermatome blades, rinsing hoses or a storage container - all no problem. It is not thrown together on a whim, but carefully selected and tuned to harmonise with each other. The weakest link is the crucial factor, and thus the quality of the accessories is a signifi cant contribution to the complete end result.

Art. No.DT-55 EX

Control UnitVoltage: 115/230V, 50-60HzPower: 160 WSpeed: 500 - 40.000 rpmConnections: 2 x motor, 1 x foot pedalDimensions: 290 x 260 x 140 mmWeight: 4.5 kg

Integrated PumpRollers: 8Capacity: max. 3l / hRegulation: 10% steps

Micro MotorSpeed: 500 - 40.000 rpmTorque: 4/10 NcmCooling: air cooled

Drill- and Shaver-System, consisting of:

2 Main control unit

2 Micro motor (+ rack)

2 Foot pedal

2 1 liter irrigation bottle (0,9% NaCl-solution, sterile)

2 Bottle holder

2 Tubing set (3 m, sterile)

Micro Drill- and Shaver System

Micro Drill & Shaver System

GK_E_1 GK_E_1

Our electronic motor, which despite a 10 Ncm torque runs smoothly has a controlled start/stop performance. With a running speed of between 500 - 40.000 rpm it easily complies to modern standards. The material and the processing ensure that heat de-velopment during long usage is kept to a mini-mum.

Simply satisfying hygiene demands is not enough. Our motto is to meet the norms of tomorrow to-day and to take the recommendations of accre-dited institutions seriously. Our otology hand-pieces and motors are approved for mechanical cleaning.

Osteotomy handpieces with external cooling - for rotating instruments with 2.35 mm shank diameter and following lenghts:

2 44.5 mm (straight only)2 70 mm2 95 mm2 125 mm

Micro Motor 10 Ncm

Osteotomy handpieces

Art.-No. Description Feature Packaging

77HW001 Handpiece angled for 70 mm burs 1 piece 77HW002 Handpiece angled for 95 mm burs 1 piece 77HW003 Handpiece angled for 125 mm burs 1 piece

77HG001 Handpiece straight for 45 mm burs 1 piece 77HG002 Handpiece straight for 70 mm burs 1 piece 77HG003 Handpiece straight for 95 mm burs 1 piece 77HG004 Handpiece straight for 125 mm burs 1 piece

Art.No. Speed Packaging

77MM010 40.000 rpm 1 piece

GK_E_1

Micro Drill- and Shaver System

Micro Drill & Shaver System

GK_E_1

2 8.000 rpm2 Cutting width 6 / 8 / 10 mm

2 Width: 12.5 mm 25 mm 50 mm 75 mm

Art.-No. Description Width Packaging

77DD012 Dermatome 12.5 mm 1 piece 77DD025 Dermatome 25 mm 1 piece77DD050 Dermatome 50 mm 1 piece77DD075 Dermatome 75 mm 1 piece

77DK012 Dermatome blades 12.5 mm 10 pieces / box77DK025 Dermatome blades 25 mm 10 pieces / box77DK050 Dermatome blades 50 mm 10 pieces / box77DK075 Dermatome blades 75 mm 10 pieces / box

Dermatomes

Mucotome

Art. No. Packaging

77MU000 1 piece

Micro Drill- and Shaver System

Micro Drill & Shaver System

GK_E_1 GK_E_1

Blades for Compass Saw

Compass saw handpiece

2 2.00 mm stroke2 External cooling

Compass saw

Art.No. Width Cutting thickness Material thickness Packaging

77SSB01 17 mm 0.4 mm 0.25 mm 1 piece 77SSB51 13 mm 0.4 mm 0.25 mm 1 piece 77SSB52 22 mm 0.4 mm 0.25 mm 1 piece

77SSB31 10 mm 0.5 mm 0.4 mm 1 piece77SSB32 13 mm 0.5 mm 0.4 mm 1 piece77SSB33 17 mm 0.5 mm 0.4 mm 1 piece77SSB41 21 mm 0.5 mm 0.4 mm 1 piece77SSB34 25 mm 0.5 mm 0.4 mm 1 piece

Art. No. Packaging

77SS000 1 piece

Art.-No. 77SSB31

Art.-No. 77SSB32

Art.-No. 77SSB51

Art.-No. 77SSB01

Art.-No. 77SSB33

Art.-No. 77SSB41

Art.-No. 77SSB52

Art.-No. 77SSB34

A patented manufacturing process results in extraordinary design and superior properties in our surgical saw blades.

During the treatment of delicate bones, Spiggle & Theis saw blades ope-rate in a steady and stable manner, which guarantees controlled guiding during cutting. This is due to the laser sharpened triangular cutting teeth which are set off positively as the result of a special etching procedure.

When using conventional saw blades, the setting of the teeth may lead to irregularities in the blade width. The teeth of Spiggle & Theis saw bla-des, however, are arranged in an exact row, which prevents the blades from undulating laterally when applied to the bone.

A very limited loss of bone substance is another distinguishing feature.

GK_E_1

Micro Drill- and Shaver System

Micro Drill & Shaver System

GK_E_1

Art.-No. 77SPB04

Art.-No. 77SPB14

Sagittal saw handpiece

2 20.000 rpm

2 External cooling

Sagittal Saw

Art. No. Packaging

77SP000 1 piece

Art.No. Cutting depth Width Cutting thickness Packaging

77SPB04 10 mm 5.9 mm 0.4 mm 1 piece 77SPB14 17 mm 9.9 mm 0.4 mm 1 piece

Saw blade set:

2 10 mm blade

2 15 mm blade

2 17 mm blade

2 21 mm blade

2 25 mm blade

Art. No. Packaging

77SSB00 1 set

Blades for compass saw

Blades for Sagittal Saw

Precise, even and very fi ne cuts are indispensable for stable positio-ning of the implant. The risk of heat generation or thermo necrosis is reduced to a minimum, mainly due to the honeycomb design typical for these blades.

2 Material thickness of 0.25 mm

Micro Drill- and Shaver System

Micro Drill & Shaver System

GK_E_1 GK_E_1

Art.-No. Width of edge Working length Packaging

77SOB04 5.7 mm 32 mm 1 piece77SOB05 9.8 mm 32 mm 1 piece77SOB06 14.6 mm 32 mm 1 piece

77SOB21 4.9 mm 46 mm 1 piece77SOB22 5.7 mm 46 mm 1 piece77SOB23 9.8 mm 46 mm 1 piece77SOB24 14.6 mm 46 mm 1 piece

Blades for Oscillating Saw

Art.-No. 77SOB04

Art.-No. 77SOB05

Art.-No. 77SOB21

Art.-No. 77SOB23

Art.-No. 77SOB06

Art.-No. 77SOB22

Art.-No. 77SOB24

Oscillating saw handpiece

2 15.000 rpm

2 External cooling

Oscillating Saw

Art. No. Packaging

77SO000 1 piece

2 0.4 mm thickness of blades

2 13 mm cutting depth

GK_E_1

Micro Drill- and Shaver System

Micro Drill & Shaver System

GK_E_1

Art.-No. 77SVG00

Art.-No. 77SVW00

2 Straight or angled

2 Compatible to micro motor Art.No. 77MM010

Shavers

Art.-No. Description Packaging

77SVG00 Shaver handpiece, straight 1 piece 77SVW00 Shaver handpiece, angled 1 piece

The shaver treatment method, usually associated with orthopaedics, was fi rst used for ENT-surgery in the USA, 1994. Since then, shaver systems have been developed continuously and are now established in many ENT clinics world-wide.

The setup of all shaver systems currently available on the market is very similar: the console, a handpiece, a motor (integrated) and a shaver blade as the working elements. There are, of course, differences in design, accessories and cutting geometries of the shaver blades. This results in the blades and handpieces of other manufacturers not being compatible with each other.

The indications for shaving lie in the minimally invasive removal of tissue in the area of the nose and the nasal cavi-ties (e.g. adenoids, nasal muscle). The principle stays the same: Tissue is sucked through the cutting window of the shaver blade into the lumen. Due to the rotation of the inner tube the sucked tissue is then severed and transported away through a hose, which is connected to a suction pump.

Micro Drill- and Shaver System

Micro Drill & Shaver System

GK_E_1 GK_E_1

Spiggle & Theis GmbH can supply you with four different cutting geometries, each in three different sizes. Choose between sterile single-use products or non-sterile reusable products. The position of the cutting window can be easily altered by adjusting the setting wheel, even whilst in use.

Shaver blades, straight

TrimmerDiameter: 2.5 / 3.5 / 4.2 mm

Spike CutterDiameter: 2.5 / 3.5 / 4.2 mm

Aggressive Full RadiusDiameter: 2.5 / 3.5 / 4.2 mm

Full Radius ResectorDiameter: 2.5 / 3.5 / 4.2 mm

Single use shaver blade, sterile

Reusable shaver blade, non-sterile

Art.-No. Description Feature Inner Ø [mm] Packaging

77SB101 Full Radius Resector single-use, sterile 3.5 5 pieces / box77SB102 Aggressive Full Radius single-use, sterile 3.5 5 pieces / box77SB111 Spike Cutter single-use, sterile 3.5 5 pieces / box77SB121 Trimmer single-use, sterile 3.5 5 pieces / box

77SB201 Full Radius Resector single-use, sterile 4.2 5 pieces / box77SB202 Aggressive Full Radius single-use, sterile 4.2 5 pieces / box77SB211 Spike Cutter single-use, sterile 4.2 5 pieces / box77SB221 Trimmer single-use, sterile 4.2 5 pieces / box

77SB301 Full Radius Resector single-use, sterile 2.5 5 pieces / box77SB302 Aggressive Full Radius single-use, sterile 2.5 5 pieces / box77SB311 Spike Cutter single-use, sterile 2.5 5 pieces / box77SB321 Trimmer single-use, sterile 2.5 5 pieces / box

77SB101-M Full Radius Resector multi-use, non-sterile 3.5 1 piece / box77SB102-M Aggressive Full Radius multi-use, non-sterile 3.5 1 piece / box77SB111-M Spike Cutter multi-use, non-sterile 3.5 1 piece / box77SB121-M Trimmer multi-use, non-sterile 3.5 1 piece / box

77SB201-M Full Radius Resector multi-use, non-sterile 4.2 1 piece / box77SB202-M Aggressive Full Radius multi-use, non-sterile 4.2 1 piece / box77SB211-M Spike Cutter multi-use, non-sterile 4.2 1 piece / box77SB221-M Trimmer multi-use, non-sterile 4.2 1 piece / box

77SB301-M Full Radius Resector multi-use, non-sterile 2.5 1 piece / box77SB302-M Aggressive Full Radius multi-use, non-sterile 2.5 1 piece / box77SB311-M Spike Cutter multi-use, non-sterile 2.5 1 piece / box77SB321-M Trimmer multi-use, non-sterile 2.5 1 piece / box

GK_E_1

Micro Drill- and Shaver System

Micro Drill & Shaver System

GK_E_1

Shaver Blades, curved

Spiggle & Theis GmbH can supply you with three different cutting geometries, each in two different sizes. The position of the cutting window can easily be altered by adjusting the setting wheel, even whilst in use. The shape of curved bla-des is especially adapted for minimally invasive use in maxillary sinus (adenoids etc.).

Art.-No. Description Feature Inner Ø [mm] Packaging

77SB111-C Full Radius Resector single-use, curved (15°), sterile 3.5 5 pieces / box77SB121-C Aggressive Full Radius single-use, curved (15°), sterile 3.5 5 pieces / box77SB131-C Spike Cutter single-use, curved (15°), sterile 3.5 5 pieces / box

77SB113-C Full Radius Resector single-use, curved (30°), sterile 3.5 5 pieces / box77SB123-C Aggressive Full Radius single-use, curved (30°), sterile 3.5 5 pieces / box77SB133-C Spike Cutter single use, curved (30°), sterile 3.5 5 pieces / box

77SB211-C Full Radius Resector single-use, curved (15°), sterile 4.2 5 pieces / box77SB221-C Aggressive Full Radius single-use, curved (15°), sterile 4.2 5 pieces / box77SB231-C Spike Cutter single-use, curved (15°), sterile 4.2 5 pieces / box

77SB213-C Full Radius Resector single-use, curved (30°), sterile 4.2 5 pieces / box77SB223-C Aggressive Full Radius single-use, curved (30°), sterile 4.2 5 pieces / box77SB233-C Spike Cutter single-use, curved (30°), sterile 4.2 5 pieces / box

Single-use shaver blade, 15°, sterile

Single-use shaver blade, 30°, sterileSingle-use shaver blade, 30°, sterile

Spike CutterDiameter: 3.5 / 4.2 mm

Full Radius ResectorDiameter: 3.5 / 4.2 mm

Aggressive Full RadiusDiameter: 3.5 / 4.2 mm

Micro Drill- and Shaver System

Micro Drill & Shaver System

GK_E_1 GK_E_1

At the end of each cleaning and disinfecting process a visual control and a functional test must be carried out to ensure that the inst-ruments are macroscopically clean and that damaged instruments are discarded before being reintegrated in the preparation cycle (see below).

The characteristics listed below determine the next step, i.e. Packaging An additional cleaning cycle Disposal

Cleanliness

Inspection Defects Result

Magnifying glass,8 –10 times magnifi ed

Not clean

Free from defects

Fracture

Free from defects

Metal abrasion

Free from defects

Corrosion

Pitting corrosion

Free from defects

Bending/Diffi cultto rotate

Free from defects

Functional test:The inner tube of the Shaver Blade is locked into the outer tube and set in rotary motion with a fi nger.

Check if there is any bending.Diffi cult to rotate:the low-vibration operation orproper chucking in the motor canno longer be guaranteed.

Residual corrosion is to be sub-jected to a special cleaning cycle. Advanced corrosion (e.g. pitting corrosion), as a result of which resistance to fracture can no longer be guaranteed, inevita-bly leads to the disposal of the instrument.

Obvious or hiddenmetal abrasion:the instrument is blunt.

Fracture or damageto inner or outer blades

Visual control, magnifying glass if necessary 8 –10 times magnifi ed

Impurities

Form and

Function

Surface

Notes:Discoloration is not a sign of inferior quality, but does indicate that:

Certain procedures are unsuitable for the instruments

There were residues of impurities left from previous procedures, e.g. resi- dues of medicine and cleaning agents

There has been non-conform be- haviour of the user, for example by omitting the pre-cleaning step in new instruments or improper storage.

Delicate instruments should always be che-cked with magnifying glasses (8 – 10 times magnifi ed). All parts of the Spiggle & Theis Shaver BlZZes must be discarded together as a whole. Do not just replace one component under any circumstances.Lubricate the inner tube of the shaver blade with an oil spray to ensure minimum friction of the inner blade. Spray from a distance of approximately 5 cm. The rotation of the inner tube in the tro-car leads to the formation of an even fi lm between the inner and the outer tube which signifi cantly reduces metal abrasion.

Checklist Shaver Blades, multi-use

Preparation cycle:Every reusable instrument, new or reused, should pass through the entire preparation cycle. Each step is essential for the true sterility of the prepared instrument, so that the risk of infection can be signifi cantly reduced for both, patient and personnel. Not macroscopically clean instruments are subjected to another cleaning and disin-fecting cycle prior to sterilization, whereas instruments that are not fi t for use must be discarded.If the verdict in all categories is „free from defects“, the instrument is ready for sterili-zation and can be packed in foil or boxes.

GK_E_1

Micro Drill- and Shaver System

Micro Drill & Shaver System

GK_E_1

Rinsing Rail

Validated Cleaning Process

Thanks to the special rinsing rail we can exclusively offer a validated mechanical and manual cleaning process for our multi-use shaver blades. This procedure is applicable for all common clinical washing machines. The setup and connec-tions are quickly in place.

Rinsing rail for automated cleaning of our shaver blades, non-sterile

2 For straight or angled shaver blades

Art.-No. Description Packaging

77R0001 Rinsing rail for shaver blades 1 piece77R0011 Stopper for rinsing rail 3 pieces

77ZZC01 77ZZC02

Art.-No. Description Packaging

77ZZC01 Clip set (small) 10 pieces / set77ZZC02 Clip set (large) 3 pieces /set

Clip sets

77ZZ901 77ZZ904 77ZSE05

Art.-No. Description Packaging

77ZZ900 Cleaning spray for motors and handpieces 1 piece77ZZ901 Spray attachment for motors 1 piece77ZZ904 Spray attachment for handpieces 1 piece77ZSE05 Irrigation tubing set, 3m 10 pieces77SBB02 Cleaning brush for shaver blades, 2.0 mm 1 piece77SBB03 Cleaning brush for shaver blades, 3.0 mm 1 piece

Cleaning accessories

77SBB02

77ZZ900

2 For motor cable


Recommended