+ All Categories
Home > Documents > Brochure WIM Compas F - Hobre.comhobre.com/files/products/Brochure_WIM_Compas_F_rev.2.pdf · WIM...

Brochure WIM Compas F - Hobre.comhobre.com/files/products/Brochure_WIM_Compas_F_rev.2.pdf · WIM...

Date post: 06-Mar-2018
Category:
Upload: buixuyen
View: 215 times
Download: 2 times
Share this document with a friend
4
Transcript
Page 1: Brochure WIM Compas F - Hobre.comhobre.com/files/products/Brochure_WIM_Compas_F_rev.2.pdf · WIM Compas™ F Specifications Service Natural gas, Fuel gas, Biogas, Flare gas etc. Measuring
Page 2: Brochure WIM Compas F - Hobre.comhobre.com/files/products/Brochure_WIM_Compas_F_rev.2.pdf · WIM Compas™ F Specifications Service Natural gas, Fuel gas, Biogas, Flare gas etc. Measuring
Page 3: Brochure WIM Compas F - Hobre.comhobre.com/files/products/Brochure_WIM_Compas_F_rev.2.pdf · WIM Compas™ F Specifications Service Natural gas, Fuel gas, Biogas, Flare gas etc. Measuring

WIM Compas™ F Specifications Service Natural gas, Fuel gas, Biogas, Flare gas etc. Measuring principle Residual Oxygen Method Sample wetted parts SS316, Inconel and Platinum Installation options - General Purpose Area - ATEX Cat 3G Ex purge (Zone 2) - ATEX Cat 2G EExp dem (ib)IIC T3 (Zone 1) - NFPA purge for Class 1 Div.2 hazardous area Measuring ranges Wobbe Index 50 MJ/Nm3 span in 0 – 100 MJ/Nm3 range Calorific Value (SG cell option) 50 MJ/Nm3 span in 0 – 120 MJ/Nm3 range CARI* span of 15 in 0 – 25 range Accuracy ± 0,4% of measured value for natural gas Repeatability ± 0,05% of measured value Drift < ±0,05% per day (on natural gas) Response time T90 < 5 seconds (lag time and T90 rise time included)

Specific Gravity cell (option) Updated signal (every 10 seconds, Hobré SG cell) SG range 0 – 3 SG accuracy < ± 0,5% of Full scale Response time CV signal < 20 seconds to T90

Specific Gravity cell (option) Continuous measurement (oscillation principle SG cell) SG range 0 – 3 SG accuracy < ± 0,5% of reading Response time CV signal < 5 seconds to T90

* CARI = Combustion Air Requirement Index Outputs Local HMI 8,4” full colour display with touchpad (all functions) Analogue outputs 2 off isolated 0/4 – 20 mA (optionally up to 4) Digital outputs - 2 off relay SPDT for malfunction and calibration status - 8 off 24VDC 1 A or volt free; service selectable Digital input Start calibration, Start validation Communication options - Remote control via TCP/IP incl. software for remote operation - MODBUS RTU via RS485 Utilities Power supply 115/230 VAC, 50/60 Hz Power consumption 850 VA max Instrument air - 10 Nl/min at 3 barG minimum - 50 Nl/min for Ex purge option (170 Nl/min pre purge flow) - 50 Nl/min for vortex cooler option Sample flow ± 1 Nl/min Sample pressure 1,5 – 5 barG for standard version 0 – 1,5 barG requires pump option Installation Mounting Wall mounting Dimensions (HxWxD) 1000 x 800 x 400 mm (non-Ex version) Weight 80 – 250 kg, depending on version Enclosure protection IP65 design Ambient temperature range Standard and ATEX 2G (Zone 1) version +5..40°C Optional -20 – +60 C (general purpose & Zone 2 version only)

Page 4: Brochure WIM Compas F - Hobre.comhobre.com/files/products/Brochure_WIM_Compas_F_rev.2.pdf · WIM Compas™ F Specifications Service Natural gas, Fuel gas, Biogas, Flare gas etc. Measuring

Order Code WIM Compas™ F

P P version (sample pressure > 1,5 barg)

LP1 LP1 version with one pump, incl. fast loop (sample pressure < 1,5 barg )

LP2 LP2 version with two pumps, incl. fast loop (sample pressure < 1,5 barg and high dew point)

C Continuous measurement principle

D High sulphur version with continuous measurement and dilution system

I High sulphur version with Injection system

115 Power supply 115 VAC, 50/60 Hz

230 Power supply 230 VAC, 50/60 Hz

0 No specific gravity meter

SGC Oscillation type specific gravity cell

SGU Hobré specific gravity cell

0 No sample pressure monitoring

SPM Sample pressure monitoring

0 General purpose area version

1 ATEX 2G (Zone 1) IIC T3 hazardous area (excluding backup purge)

2 ATEX 2G (Zone 1) IIC T3 hazardous area (including backup purge and frame)

3 ATEX 3G (Zone 2) IIC T3 hazardous area version *

Z NFPA Z-purge for NEC class 1 div 2

2 2 analog outputs

4 4 analog outputs

0 No serial communication

R Remote operation via TCP/IP

RO Remote operation via optical fiber

M Modbus RTU via RS485

MO Modbus RTU via optical fiber

0 No extra isolated relais added

R 8 off extra isolated relais added (already included in ATEX 2G, Zone 1 version)

0 No additional fast loop inside the analyser

F Fast loop installed inside analyser

FA Fast loop with alarm installed inside analyser

0 Standard ambient temperature range 5 - 40°C

H Heated electronics for low ambient temperature (down to -20°C)

C Vortex cooler for high ambient temperature (up to 60°C, not available for ATEX 2G Zone 1)

HC Version for ambient temperature range -20 up to +60°C ( not available for ATEX 2G Zone 1)

1 No additional frame included

2 Analyser mounted on free standing frame (SS304)

3 Analyser mounted on free standing frame with sunroof

* In case of purge failure the analyser will not be switched off.