Page 1 of 10 SOFTWARE OPERATIONS Browser Control for MA-725F/MM-700F 1. Browser Control Outline 1.1. General Description The browser Control feature allows password protected control of source, volume control and options on either an MA-725F or MM-700F from a browser on your PC (Internet Explorer, Google Chrome, Firefox, etc.). Smartphones (iOS or Android devices) using a browser function are also supported. Note: When browser control is active, the front panel and any WP-700 AM controllers will be disabled. 1.2. System Requirement Any PC or MAC with a web browser. Any iOS or Android smart phone. Firmware update requires a PC running Win 7 or Win 10. The MA-725F or MM-700F will require the version of firmware (v2.05) or latest 2. Browser Operations 2.1. Browser Access Page Point your browser to the mixer’s default IP address of 192.168.14.1 (first make sure your computer’s IP address is in the same range as the mixer 192.168.14.xxx). The default user name is “admin”. The default password is “admin”. NOTE: IF YOU CANNOT CONNECT TO THE DEFAULT IP ADDRESS, YOU MAY NEED TO UPDATE THE SYSTEM FIRMWARE. REFER TO SECTION 3 INSTRUCTIONS ON PAGES 5 AND 6 OF THIS DOCUMENT.
Transcript
Page 1: Browser Control for MA-725F/MM-700F - GoWild AGshop.gowild.ch/shop/resources/downloads/MA-725F_and_MM...an MA-725F or MM-700F from a browser on your PC (Internet Explorer, Google Chrome,

Page 1 of 10

SOFTWARE OPERATIONS

Browser Control for MA-725F/MM-700F 1. Browser Control Outline 1.1. General Description

The browser Control feature allows password protected control of source, volume control and options on either an MA-725F or MM-700F from a browser on your PC (Internet Explorer, Google Chrome, Firefox, etc.). Smartphones (iOS or Android devices) using a browser function are also supported.

Note: When browser control is active, the front panel and any WP-700 AM controllers will be disabled.

1.2. System Requirement

Any PC or MAC with a web browser. Any iOS or Android smart phone. Firmware update requires a PC running Win 7 or Win 10. The MA-725F or MM-700F will require the version of firmware (v2.05) or latest

2. Browser Operations 2.1. Browser Access Page

Point your browser to the mixer’s default IP address of 192.168.14.1 (first make sure your computer’s IP address is in the same range as the mixer 192.168.14.xxx). The default user name is “admin”. The default password is “admin”.

NOTE: IF YOU CANNOT CONNECT TO THE DEFAULT IP ADDRESS, YOU MAY NEED TO UPDATE THE SYSTEM FIRMWARE. REFER TO SECTION 3 INSTRUCTIONS ON PAGES 5 AND 6 OF THIS DOCUMENT.

Page 2: Browser Control for MA-725F/MM-700F - GoWild AGshop.gowild.ch/shop/resources/downloads/MA-725F_and_MM...an MA-725F or MM-700F from a browser on your PC (Internet Explorer, Google Chrome,

Page 2 of 10

2.2. Operations

This is the mixer’s landing page for the URL. It allows control of source selection and volume.

To get to the options menu, click on the Gear icon at the top right of the screen as indicate round mark in red color.

Control Screen with Menu

All Zone: View all zones on one page

Zone: 1 – 4

View individual zones on one page

Page 3: Browser Control for MA-725F/MM-700F - GoWild AGshop.gowild.ch/shop/resources/downloads/MA-725F_and_MM...an MA-725F or MM-700F from a browser on your PC (Internet Explorer, Google Chrome,

Page 3 of 10

2.3. Control Center Allows the user to turn Browser Control On or Off using the green “LED”. Green indicates Browser control is on. Grey indicates Browser control is off. Volume and zone selection are also possible from this window.

Control Center Screen

2.4. Network Configuration

View or change the unit’s IP address and view Firmware version

Network Configuration Screen

Page 4: Browser Control for MA-725F/MM-700F - GoWild AGshop.gowild.ch/shop/resources/downloads/MA-725F_and_MM...an MA-725F or MM-700F from a browser on your PC (Internet Explorer, Google Chrome,

Page 4 of 10

2.5. Password Setting Up to 6 digits (Letters and numbers only. No special characters)

Password Setting Screen

2.6. Browser Control Release To return control to the wall controllers or front panel, hold down Input Select buttons 1-4 on Zone 1 for more than 4 seconds.

Page 5: Browser Control for MA-725F/MM-700F - GoWild AGshop.gowild.ch/shop/resources/downloads/MA-725F_and_MM...an MA-725F or MM-700F from a browser on your PC (Internet Explorer, Google Chrome,

Page 5 of 10

3. How to Update MA-725F/MM-700F Firmware

Connect a straight Ethernet cable from your Windows PC to the MA-725F/MM-700F and turn the MA-725F/MM-700F Off.

Push and hold the Input 1 select switch on Zone 1

Restart the MA-725F/MM-700F. When the Power LED starts flashing, release the input 1 select switch.

You will see the Firmware Upgrade Tool. Click on the executable file and run the program.

Press the “Connect” button to start communication with the MA-725F/MM-700F.

Press “Load New FW” and select updating new firmware.

Press “Upgrade Firmware” button to start the firmware update.

If the update is successful, your screen will resemble the

illustration to the right. >>

Turn the MA-725F/MM-700F Off.

Page 6: Browser Control for MA-725F/MM-700F - GoWild AGshop.gowild.ch/shop/resources/downloads/MA-725F_and_MM...an MA-725F or MM-700F from a browser on your PC (Internet Explorer, Google Chrome,

Page 6 of 10

Push and hold the input select switches 2 and 3 under Zone 1 and restart the MA-725F/MM-700F.

The default IP address of the unit has been changed to 192.168.14.1.

Use this IP address to reconnect to the MA-725F/MM-700F through your browser.

Page 7: Browser Control for MA-725F/MM-700F - GoWild AGshop.gowild.ch/shop/resources/downloads/MA-725F_and_MM...an MA-725F or MM-700F from a browser on your PC (Internet Explorer, Google Chrome,

Page 7 of 10

PAGING OPERATIONS

Selectable Paging Function by RM-9012C

4. Selectable Paging 4.1. General Description

The paging function feature is able to broadcast the paging from RM-9012C to selected zones by zone keys of RM-9012C using special cables between MA-725F and RM-9012C. Note :

・Paging function is available from the firmware version 3 or later.

・Firmware version 3 or later have a possibility to select operation modes, either normal

operation mode or paging operation mode.

・Paging operation mode has functional limitations from among the normal operation mode

instead of realizing the paging functions.

・It is required to prepare the special cables to connect the RM-9012C and MA-725F.

4.2. Features Possible to broadcast the paging to selected zones from RM-9012C Up to 2 RM-9012C are able to connect to MA-725F Up to 2 WP-700 are able to connect to MA-725F Web-browser function are also available.

4.3. Firmware Updating

The procedure of firmware updating is same as section 3 “How to update MA-725F/MM-700F Firmware”.

4.4. Select the Operation Mode

Depends on your application, you can select the operation mode either normal operation mode or paging operation mode by following procedure after updating the firmware to version 3 or later.

4.4.1. Turn the power of the unit OFF.

4.4.2 Hold the input select key 3 on output CH4.

Page 8: Browser Control for MA-725F/MM-700F - GoWild AGshop.gowild.ch/shop/resources/downloads/MA-725F_and_MM...an MA-725F or MM-700F from a browser on your PC (Internet Explorer, Google Chrome,

Page 8 of 10

4.4.3 Turn the power of the unit ON.

4.4.4 All of LEDs in front of the MA-725F will blink 3 times than reset → Start the paging operation mode

In order to switch back to the normal operation mode, you follow 4.4.1. – 4.4.3. again.

Then all of LEDs in front of the MA-725F will blink 6 times than reset → Start normal operation mode

4.5. Connection

4.5.1 Cable preparation to connect RM-9012C and MA-725F

In order to connect RM-9012C and MA-725F, following cable should be prepared.

Page 9: Browser Control for MA-725F/MM-700F - GoWild AGshop.gowild.ch/shop/resources/downloads/MA-725F_and_MM...an MA-725F or MM-700F from a browser on your PC (Internet Explorer, Google Chrome,

Page 9 of 10

4.5.2 Connection of RM-9012C

Up to 2 RM-9012C are able to connect to a MA-725F as below.

・Audio Line of Mic.1 should be connected to the connector H/C/E of PRIORITY 1 input,

and also RJ45 connector should be connected to REMOTE CH 2.

・Audio Line of Mic. 2 should be connected to the connector H/C/E of PRIORITY 2 input,

and also RJ45 connector should be connected to REMOTE CH 4.

RM-9012C Mic. 2 RM-9012C Mic. 1 (with AD-246) (with AD-246)

Note :

・Position of DIP SWs 1-4 for PRIORITY 1 and 2 are ignored

・Position of DIP SW 6 for PRIORITY 1 and 2 should be OFF (Line) as audio output from

RM-9012C is Line level.

・In case the switch PRIORITY MIX 1+2 is OFF, the behavior is same as normal mode.

(Audio signals of PRIORITY 1 and 2 are not mixed)

・In case the switch PRIORITY MIX 1+2 is ON, always audio signals from PRIORITY 1 and 2

are mixed.

Page 10: Browser Control for MA-725F/MM-700F - GoWild AGshop.gowild.ch/shop/resources/downloads/MA-725F_and_MM...an MA-725F or MM-700F from a browser on your PC (Internet Explorer, Google Chrome,

Page 10 of 10

4.5.3 Connection of WP-700 Up to 2 WP-700 are able to connect to a MA-725F as below.

・WP-700 should be connected to REMOTE CH 1 or CH 3.

WP-700 unit 2 WP-700 unit 1

Note :

・Regardless the position of the switch REMOTE LINK, it works as ON permanently.

(CH1 and 2 are always linked, same as CH3 and CH4)

4.6. Operation Following shows the using keys of RM-9012C. Details are written on the manual of RM-9012C.

① Channel Selector key (CH 1 to CH 4)

Select the desired zones for the announcement

② Talk key

It is a press-to-talk key for the announcement


Recommended