27
VCA Headquarters 1 The Eastgate Office Centre Eastgate Road Bristol, BS5 6XX United Kingdom Switchboard: +44 (0) 117 951 5151 Main Fax: +44 (0) 117 952 4103 Email: [email protected] Web: www.vca.gov.uk Job number VSM246589 An executive agency of the Department for Transport BS EN 1789:2007 Certificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment 1, in order to achieve compliance for MOUNTING SYSTEMS. Appropriate tests have been witnessed by the Vehicle Certification Agency and the Vehicle Certification Agency have documented the specification of the vehicle tested. See VCA test report(s): VSM246589 Reason for extension: Not Applicable 1. Make (trade name of manufacturer): Getac UK Ltd. 2. Type and general description: V Series Laptop Dock 3. Means of Identification: Adhesive specification label 4. Location of that Marking: Rear of docking station 5. Category of Vehicle: N/A System of components 6. Name and Address of Manufacturer: Getac (UK) Ltd, Nedge Hill, Telford, Shropshire, TF3 3AH UK 7. If approved as a Separate Technical Unit, Location of that marking: Rear of docking station 8. Remarks: An information file containing test reports, drawings and statements is held on file at VCA. Issue Number: VSM246589 Job Number: VSM246589 A.W. Stenning Head of Technical and Quality Group U K A p p r o v a l A u t h o r i t y 20-Dec-11
Transcript
Page 1: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

VCA Headquarters 1 The Eastgate Office Centre Eastgate Road Bristol, BS5 6XX United Kingdom

Switchboard: +44 (0) 117 951 5151 Main Fax: +44 (0) 117 952 4103 Email: [email protected] Web: www.vca.gov.uk

Job number VSM246589 An executive agency of the Department for Transport

BS EN 1789:2007 Certificate of Compliance

This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment 1, in order to achieve compliance for

MOUNTING SYSTEMS. Appropriate tests have been witnessed by the Vehicle Certification Agency and the Vehicle Certification Agency have documented the specification of the vehicle tested. See VCA test report(s): VSM246589 Reason for extension: Not Applicable 1. Make (trade name of manufacturer): Getac UK Ltd.

2. Type and general description: V Series Laptop Dock

3. Means of Identification: Adhesive specification label

4. Location of that Marking: Rear of docking station

5. Category of Vehicle: N/A System of components

6. Name and Address of Manufacturer: Getac (UK) Ltd,

Nedge Hill, Telford, Shropshire, TF3 3AH UK

7. If approved as a Separate Technical Unit, Location of that marking: Rear of docking station

8. Remarks: An information file containing test reports, drawings and statements is

held on file at VCA.

Issue Number: VSM246589 Job Number: VSM246589 A.W. Stenning Head of Technical and Quality Group

UK Approval Auth

orit

y

20-Dec-11

Page 2: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

V100 VEHICLE DOCK

QUICK START GUIDE

Rugged Mobile Computing Solutions

UK Approval Auth

orit

y

20-Dec-11

Page 3: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

2

1. Taking a Look

The Vehicle Dock, with Port Replicator feature, mounts your V100 securely in a vehicle.

Top and Bottom

Port Replicator

1 Studs attach and secure to the pedestal. 2 For external antenna connection (optional). 3 For connecting a video device with BNC interface, such as a CCD Camera.

Latch

2 Guide Pins (circled)

LockPort Replicator

(see figure below)

4 Studs (circled) 1

Guide PinGuide Pin

USB PortsSerial Ports

Power Connector

Audio Output Connector

MicrophoneConnector

WLAN Antenna Pass-Through Connector 2

WWAN Antenna Pass-Through Connector 2

LAN (RJ-45) Port

BNC Video Capture Connector 3

Docking Connector

UK Approval Auth

orit

y

20-Dec-11

Page 4: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

3

2. Mounting the Vehicle Dock

Mounting the Vehicle Dock in a vehicle should be performed by qualified technicians.

The mechanical diagrams provide dimensions (in mm) for installation to the vehicle pedestal.

The above diagram shows the dimensions for the Dock Studs/Bolts. The dimensions of the Pedestal Studs/Bolts must match accordingly.

UK Approval Auth

orit

y

20-Dec-11

Page 5: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

4

3. Docking and Undocking

Docking

1. Make sure that the Vehicle Dock drivers have been installed. (See Chapter 6 of V100 User’s Manual for installation instructions.)

2. Connect the cables of the peripheral devices to the corresponding connectors on the Vehicle Dock. (Refer to page 2.)

3. Connect one end of the Car Adapter to the Vehicle Dock and the other end to the cigarette lighter in the vehicle.

4. Slide open the docking connector cover on the bottom of V100.

5. By aligning V100 with the guide pins on the Vehicle Dock (refer to the first figure on page 2), carefully plug the docking connector of V100 to the connector on the Vehicle Dock.

UK Approval Auth

orit

y

20-Dec-11

Page 6: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

5

6. Push down the lever to secure V100 on the dock. Then, turn the lock to the locked position with the key.

CAUTION: The Vehicle Dock must be locked with the key for the system to operate safely and properly. 7. Start up V100.

When the Car Adapter is plugged into the cigarette lighter, power will be supplied from the vehicle to V100, with the battery being charged at the same time.

UK Approval Auth

orit

y

20-Dec-11

Page 7: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

6

Undocking

Follow this procedure to undock V100:

1. Turn the lock to the unlocked position with the key.

2. Pull up the latch to release V100.

3. Lift V100 away from the Vehicle Dock.

UK Approval Auth

orit

y

20-Dec-11

Page 8: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

7

UK Approval Auth

orit

y

20-Dec-11

Page 9: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

8

5 6 1 5 1 2 5 3 0 0 0 5 R 0 1

UK Approval Auth

orit

y

20-Dec-11

Page 10: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

Vehicle Certification Agency, 1 The Eastgate Office Centre Eastgate Road, Bristol, BS5 6XX, United Kingdom. Telephone: 0117 951 5151 www.vca.gov.uk

TEST REPORT: Medical vehicles and their equipment – Road Ambulances BS EN 1789:2007 TEST REPORT NUMBER: VSM246589

BS EN 1789:2007 TR1789 Dynamic Rev00 Report/Job Number: VSM246589 Page 1 of 5

TEST DETAILS Subject Ambulances – maintaining systems and fixations of the

equipment in the patients compartment BS/EN Standard BS EN 1789:2007 paragraph 4.5.9. and 5.3. Location of Test(s) MIRA, Watling Street, Nuneaton, Warwickshire, UK Date(s) of Test(s) 08/12/2011 VCA Representative Brent Waddington Manufacturer’s Representative Chris Doran Reason for Test New approval for Getac V Series laptop vehicle mount

MANUFACTURER DETAILS Manufacturer’s Name Getac (UK) Ltd Manufacturer’s Address Getac (UK) Ltd

Mitac House Nedge Hill Telford TF3 3AH

Component description V Series Light Dock Category n/a

CONCLUSION The above mentioned vehicle was tested in accordance with BS EN 1789:2007 Paragraph 4.5.9 and 5.3 and was found to comply in all respects

Signature:

Name: Brent Waddington Steve Holdcroft Position: Type Approval Engineer Principal Engineer Date: 20 December 2011 20 December 2011

LIST OF ANNEXES ANNEX No of PAGES SUBJECT

1 2 3

UK Approval Auth

orit

y

20-Dec-11

Page 11: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

TEST REPORT: Road AmbulancesBS EN 1789:2007

BS EN 1789:2007 TR1789 Dynamic Rev00 Report/Job Number: VSM246589 Page 2 of 5

TEST VEHICLE SPECIFICATION/ WORST CASE RATIONALE: Laptop dock - V Series Light Dock Part No. 541125500301 = 2.63kg Laptop - V100X Laptop 52621255003L = 2.9kg Perform dynamic tests to BS EN 1789:2007 Paragraph 4.5.9: All items, e.g. medical devices equipment and objects normally carried on the road ambulances shall be restrained, installed or stowed to prevent them from becoming a projectile when subjected to accelerations / decelerations of 10g in the forward, rearward, left, right and vertical directions. Laptop docked to docking station for all tests. Equipment used for test Calibration due date: Accelerometer(s): 9461 and 17112 18/03/12 and 23/11/12 Amplifier/Signal Conditioner: 014434 23/07/12 Data Acquisition: 030084 23/07/12 Test Control unit (Speed): 021825 23/07/12 70mm Timing eye: 21767 30/05/12 TEST 1 Date of test: 08 December 2011 VCA Witness: Brent Waddington Complies Test Set-up V100X laptop docked to V Series Light dock. Docking station mounted to sled in forward direction.

Pre-Test Checks Fixtures present: All as shown in manufacturers documents Yes Deceleration Results Pulse meets requirements of BS EN 1789:2007, Figure 6 Yes Post test inspection V Series Light Dock Yes V100X Laptop Yes Remarks

UK Approval Auth

orit

y

20-Dec-11

Page 12: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

TEST REPORT: Road AmbulancesBS EN 1789:2007

BS EN 1789:2007 TR1789 Dynamic Rev00 Report/Job Number: VSM246589 Page 3 of 5

TEST 2 Date of test: 08 December 2011 VCA Witness: Brent Waddington Complies Test Set-up V100X laptop docked to V Series Light dock. Docking station mounted to sled in lateral LHS direction.

Pre-Test Checks Fixtures present: All as shown in manufacturers documents Yes Deceleration Results Pulse meets requirements of BS EN 1789:2007, Figure 6 Yes Post test inspection V Series Light Dock Yes V100X Laptop Yes Remarks TEST 3 Date of test: 08 December 2011 VCA Witness: Brent Waddington Complies Test Set-up V100X laptop docked to V Series Light dock. Docking station mounted to sled in rearwards direction.

Pre-Test Checks Fixtures present: All as shown in manufacturers documents Yes Deceleration Results Pulse meets requirements of BS EN 1789:2007, Figure 6 Yes

UK Approval Auth

orit

y

20-Dec-11

Page 13: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

TEST REPORT: Road AmbulancesBS EN 1789:2007

BS EN 1789:2007 TR1789 Dynamic Rev00 Report/Job Number: VSM246589 Page 4 of 5

Post test inspection V Series Light Dock Yes V100X Laptop Yes Remarks TEST 4 Date of test: 08 December 2011 VCA Witness: Brent Waddington Complies Test Set-up V100X laptop docked to V Series Light dock. Docking station mounted to sled in lateral RHS direction.

Pre-Test Checks Fixtures present: All as shown in manufacturers documents Yes Deceleration Results Pulse meets requirements of BS EN 1789:2007, Figure 6 Yes Post test inspection V Series Light Dock Yes V100X Laptop Yes Remarks

UK Approval Auth

orit

y

20-Dec-11

Page 14: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

TEST REPORT: Road AmbulancesBS EN 1789:2007

BS EN 1789:2007 TR1789 Dynamic Rev00 Report/Job Number: VSM246589 Page 5 of 5

TEST 5 Date of test: 08 December 2011 VCA Witness: Brent Waddington Complies Test Set-up V100X laptop docked to V Series Light dock. Docking station mounted to sled in vertical direction.

Pre-Test Checks Fixtures present: All as shown in manufacturers documents Yes Deceleration Results Pulse meets requirements of BS EN 1789:2007, Figure 6 Yes Post test inspection V Series Light Dock Yes V100X Laptop Yes Remarks None

UK Approval Auth

orit

y

20-Dec-11

Page 15: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

1031824-01a

Test Results

BS EN 1789 Dynamic Tests on Laptop and Dock

Customer:

Chris Doran Getac (UK) Ltd Mitac House Nedge Hill Telford TF3 3AH

MIRA Contact: James Vey Safety Development Dept MIRA Ltd Watling Street Nuneaton CV10 0TU

Authority: K0910282 Witnesses: J Vey, V Smith - MIRA C Doran - Getac (UK) Ltd B Waddington - VCA

Test Date(s): 08/12/2011

Prepared By:

Approved By:

J Vey C Harper

Project Engineer Principal Engineer

Date:12th December 2011 © MIRA Ltd 2011. All rights reserved, subject to client contract. Information contained in this document may not be published in any

form of advertising or other matter without prior agreement of the CEO of MIRA.

MIRA Ltd. Registered Office: Watling Street · Nuneaton · Warwickshire · CV10 0TU · England · http://www.mira.co.uk Tel: +44 (0)24 7635 5000 · Fax: +44 (0)24 7635 8000 Registered in England No 402570 · VAT Registration GB 100 1464 84

Test Objective / Method / Specification No

Perform dynamic tests to BS EN 1789:2007 Paragraph 4.5.9:

All items, e.g. medical devices equipment and objects normally carried on the road ambulance shall be restrained, installed or stowed to prevent them from becoming a projectile when subjected to accelerations / decelerations of 10g in the forward, rearward, left, right and vertical directions.

Specimen Description / Part No(s)

Laptop dock – V-series light dock

Laptop – V100X

Test Equipment

MIRA linear impact sled and instrumentation as listed in Appendix

Attachments

Graphs 1 – 5

Photos 1 – 12

Appendix – Quality Assurance of Measurements

Test Results Summary

The subject was tested in accordance with the test specification with deviation*. The acceptance criteria of the test specification were:

*Deceleration levels exceeded pre-set limits in tests 1, 3 & 5.

Met Not Met See comments

UK Approval Auth

orit

y

20-Dec-11

Page 16: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

MIRA-1031824-01a BS EN 1789 Dynamic Tests on Laptop and Dock

Test Results : Page 2 of 13 Getac (UK) Ltd

UK Approval Auth

orit

y

20-Dec-11

Page 17: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

MIRA-1031824-01a BS EN 1789 Dynamic Tests on Laptop and Dock

Test Results : Page 3 of 13 Getac (UK) Ltd

UK Approval Auth

orit

y

20-Dec-11

Page 18: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

MIRA-1031824-01a BS EN 1789 Dynamic Tests on Laptop and Dock

Test Results : Page 4 of 13 Getac (UK) Ltd

UK Approval Auth

orit

y

20-Dec-11

Page 19: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

MIRA-1031824-01a BS EN 1789 Dynamic Tests on Laptop and Dock

Test Results : Page 5 of 13 Getac (UK) Ltd

UK Approval Auth

orit

y

20-Dec-11

Page 20: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

MIRA-1031824-01a BS EN 1789 Dynamic Tests on Laptop and Dock

Test Results : Page 6 of 13 Getac (UK) Ltd

UK Approval Auth

orit

y

20-Dec-11

Page 21: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

MIRA-1031824-01a BS EN 1789 Dynamic Tests on Laptop and Dock

Test Results : Page 7 of 13 Getac (UK) Ltd

Photo 1 V-series light dock

Ref 1658

Photo 2 V100X laptop

Ref 1660

UK Approval Auth

orit

y

20-Dec-11

Page 22: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

MIRA-1031824-01a BS EN 1789 Dynamic Tests on Laptop and Dock

Test Results : Page 8 of 13 Getac (UK) Ltd

Photo 3 Laptop and dock on sled prior to forward test

Ref 1634

Photo 4 Laptop and dock on sled after forward test

Ref 1637

UK Approval Auth

orit

y

20-Dec-11

Page 23: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

MIRA-1031824-01a BS EN 1789 Dynamic Tests on Laptop and Dock

Test Results : Page 9 of 13 Getac (UK) Ltd

Photo 5 Laptop and dock on sled prior to left test

Ref 1640

Photo 6 Laptop and dock on sled after left test

Ref 1641

UK Approval Auth

orit

y

20-Dec-11

Page 24: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

MIRA-1031824-01a BS EN 1789 Dynamic Tests on Laptop and Dock

Test Results : Page 10 of 13 Getac (UK) Ltd

Photo 7 Laptop and dock on sled prior to rearward test

Ref 1643

Photo 8 Laptop and dock on sled after rearward test

Ref 1646

UK Approval Auth

orit

y

20-Dec-11

Page 25: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

MIRA-1031824-01a BS EN 1789 Dynamic Tests on Laptop and Dock

Test Results : Page 11 of 13 Getac (UK) Ltd

Photo 9 Laptop and dock on sled prior to right test

Ref 1648

Photo 10 Laptop and dock on sled after right test

Ref 1649

UK Approval Auth

orit

y

20-Dec-11

Page 26: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

MIRA-1031824-01a BS EN 1789 Dynamic Tests on Laptop and Dock

Test Results : Page 12 of 13 Getac (UK) Ltd

Photo 11 Laptop and dock on sled prior to vertical test

Ref 1651

Photo 12 Laptop and dock on sled after vertical test

Ref 1654

UK Approval Auth

orit

y

20-Dec-11

Page 27: BS EN 1789:2007 Certificate of ComplianceCertificate of Compliance This Vehicle has satisfied all requirements of paragraph(s) 4.5.9 and 5.3 of BS EN 1789:2007 including Amendment

MIRA-1031824-01a BS EN 1789 Dynamic Tests on Laptop and Dock

Test Results : Page 13 of 13 Getac (UK) Ltd

Appendix 1 Quality Assurance of Measurements

The test equipment is checked on a regular schedule to traceable standards in an International Assurance of Measurements (QAM) procedure. Each item of equipment is issued with a QAM number. The numbers for the equipment used in these tests were:-

Description QA Number CAC Due on

Accelerometer 9461 200g 18/03/2012

Accelerometer 17112 200g 23/11/2012

Amplifier 14434 - 23/07/2012

Data Acquisition Unit 30084 - 23/07/2012

Test Control Unit 21825 - 23/07/2012

Channel Sample Rate: 10,000/sec