1
OmnicareEmergency Voice Communications
BS5588 Part 11 & BS5839MADE IN
5 years warranty
Photos & informations for commercial use only - we reserve the right to change without prior notice
FT000457B-Omnicare EN
• OmniCare isanaddressablevoicecommunicationsystemthatallows disabled refuge, fire telephones, emergency/stewardtelephonesanddisabledtoiletalarmstobeconnectedtoonemastercontrolpanel.
• Our disabled refuge have been made to help the physicalimpaired people in the refuge areas. The person in need ofassistance ishelped to theclosest refugeareaandawaits safeevacuation.Theyprovide the capacity to communicate handsfreewith the firemen.They are adapted to several handicaps(mobile,visual,auditory).
• Thearchitectureisbasedonamasterpanelwhichmonitorsallthesystemanditcanbecombinedwithslavespanel.Theconnectionmayberealizedinaloop(Omnicare)orinradial(Care2)(NB:OmnicareandCare2systemsarenotcompatible).
• OmniCarehasbeendesignedandbuilttomeetBS9999:2008,BS5839-9:2011andBS8300:2009(forthedisabledtoiletalarm)
BVOC4 to BVOC32-way BVOC48 to BVOC64-way BVOC80 to BVOC128-way
Powersupply 230VAC
Powerconsumption(VA) 10VA+1VAperremotehandsetfitted
Humidityrange 95%non-condensing
Operatingtemperature -10°Cà+30°C
Indicators Inuse,call,fault,power,chargeandspeechvolume
Remotesignalingoffault Volt-freecontact,closing/opening(setoncommissioning)
Dimensionsmm 410x290x200 410x455x200 410x777x200
Bezeldimensionsmm(radius) 461x340(25) 461x506(25) 461x827(25)
Bezelcutoutmm 420x300 420x465 420x787
Mountingposition Verticalcentreofcontrolsshouldbeatheightof1,4-1,5m(BS5839-9)
• Audiodigitale
• Illimited number of master panels can be connected on thesystem
• Slavespanelscancommunicatewithallthedisabledrefugesoronlywiththeselecteddisabledrefuges
• Speechsteered(disabledrefugeremotes)andfullduplexspeech(firetelephonesandemergencytelephones).
• Systemfullymonitored
• Battery backed for use in the event of power failure : 3h ofcompletecommunicationafter4hoursofelectricalcutout
• Indicators for: in use/occupied, call, fault, power, charger andspeechvolume.
• Loopinstallationenablesapermanentoperating
• Upto200mcablerunbetweenremoteunitsandmastercontrolpanelasstandard.
• Arepeaterunit (BVFREPEM)mustbeused ifdistancebetweenremotesexceeds200m.
• StandardboxinABSorOptionalstainlesssteelfinish(BVOCXMS)
Master panels BVOCX
2
Photos & informations for commercial use only - we reserve the right to change without prior notice
OmnicareEmergency Voice Communications
FT000457B-Omnicare EN
TYPICALSYSTEMANDNETWORKINGSOLUTIONS:
Flushmountingfirerefugeemergencyintercoms:
Typicalsystem-placinganytypeofremoteonasingleloop.
Typically20-30remotespersingleloop.
DisabledtoiletalarmsconnectedtoOmniCaresystemviaarepeaterunit(BVFREPEM).
Anynumberofdisabledtoiletalarmscanbeconnectedperrepeater,however,theywillshowasonecallpointonthemastercontrolpanel.
Typicalnetworksystem,providingbothlocalcontrolorcompletesystemcontrolfrom‘gatehouse’masterpanel.
KEY:Enhanced4-corefireratedcable.
4-coresecuritycable(notfirerated).
‘gatehouse’
building1 building2 building3
48-waymasterpanel
16-waymaster(orslave)panels
3
Photos & informations for commercial use only - we reserve the right to change without prior notice
OmnicareEmergency voice Communication
FT000457B-Omnicare EN
AS:surfacemountable-AF:flushmountable-P:pushdoor-L:lockingdoor-R:red-G:green-S:stainlesssteel-B:beacon
Disabledrefugewithresetting,braille,withorwithoutbeacon
Flushmountablebox
Disabled refuge with
reset (DRS)
Advanced disabled
refugeFire telephone
Emergency / steward
telephone
Combined DRS and fire
telephone
Productcode-BVOC... ECPG/ECPS AS/AF F/FB/FL/FLB/FS/FSL ET/ETB/ETL/ETLB C/CB/CL/CLB/CSP/CSL
Powersupply 12-40VDCselfpoweredfromringcircuit
Powerconsumption 30mA@35V 35mA@35V
Weight 1kg 1kg 4kg 4kg 4.5kg
Humidityrange 95%non-condensing
Operatingtemperature -10°Cto+40°C
Indicators Systemhealthy,statusSystemhealthy,system
activated,inuseSystemhealthy Systemhealthy
Systemhealthy,call
status
Finish Greenorstainlesssteel
GreenwithBraille&
tactile/luminescenttext
withinductionloop
Redorstainlesssteelwith
inductionloop
Green
withinductionloop
Redorstainlesssteelwith
inductionloop
Dimensionsmm 134x134x56encas.:178x440x3
surface:180x440x64130x350x100 130x350x100 130x480x100
DimensionsBezelmm
(radius)154x154x(10) 170x390x(20) 170x390x(20) 170x520
CutoutBezelmm 136x136 138x358 138x358 138x488
Flushmountcutoutmm 133x235x65
Knockouts/cableentry
points
7(20mm&26mm) 20mm&25mm 20mm&25mm 20mm&25mm 20mm&25mm
Mountingposition Remotesshouldbeplacedatheightof1,3-1,4m,ORinrefugeareasatheightof0,9-1,2m
Poduct code and description Bezel Dimensions
BVOCECPGDisabledrefugeremotestandardgreen BVCRMGRN 154x154mm
BVOCECPSDisabledrefugeremotestandardstainlesssteel BVCRMSS 154x154mm
BVOCECPDisabledrefugeremotestandardred BVCRMRED 154x154mm
BVOCF/CFLFiretelephoneredwithpushorlockingdoor BVFHBEZ 170x390x20mm
BVOCFS/SLFiretelephonestainlesssteelwithpushorlockingdoor BVFHBEZSS 170x390x20mm
BVOCET/ETLEmergency/Stewardtelephonepushorlockingdoor,green BVOCETBZ 170x390x20mm
BVOCC/CLFiretelephoneandcombinedfiretelephone/disabledrefugeredwithpushorlockingdoor BVOCFBR 170x520mm
BVOCET/CCSLFiretelephoneandcombinedfiretelephone/disabledrefugestainlessstellwithpushorlockingdoor BVOCFBS 170x520mm