  • BTS CALIBRATION

    Introduction to scripts Applying scripts VSWR using Anritsu Site Master CTU1 TX Calibration CTU2 TX Calibration Cable configuration

  • BTS CALIBRATION

    A.BOURI Page 2

    Command Scripts :

    Scripts for TX and RX calibration are required to be added to Procom Plus to make the activity easier and less time consuming.

    These are list of commands for specific activities, which run automatically on a single click, and the desired output is achieved

    Scripts Location:

    Add the script files to the following location C:\ Program Files\ Procom Plus\Aspect All scripts are automatically picked up from Aspect file by Procom plus software

    Meta Keys:

    Meta Keys are user defined buttons to directly execute a script or a command

  • BTS CALIBRATION

    A.BOURI Page 3

    Creating single Command Key :

    Creating script application Key :

  • BTS CALIBRATION

    A.BOURI Page 4

    VSWR TEST

  • BTS CALIBRATION

    A.BOURI Page 5

    Steps to perform :

    Turn on Site Master by pressing ON/OFF

    Press Enter to Continue

    Press RECALL SETUP and select GSM900 or DCS 1800 accordingly

    Move to Level 3 and lock all DRIs of the sector in which sweep test (VSWR) is required

    Remove feeder cable from the respective DRIs DUP and connect it with RF OUT port of site master

    Wait for 10 seconds and graphical display will appear showing the reflection throughout cable length.

    Press MARKER, select M1 and then press EDIT, now u can move the marker through the cable length and check reflections at any desired distance

    To save a current reflection, press SAVE DISPLAY, save by site name and fault location for easy access in future

    To view a previous display, press RECALL DISPLAY

    Calibrating Site Master :

    If site Master shows CAL OFF, calibrate as follows with the dummy load, labeled with open, short and load.

    Press Start Cal

    Connect OPEN to the RF OUT port, it will show success

    Now calibrate by connecting SHORT

    connect LOAD with RF out port of site master

    Setting to GSM900 :

    Press MODE

    Select FREQ-SWR and press ENTER

    Press F1 and enter lower limit

    Example F1 = 830.00 MHZ

    Press F2 and enter upper limit

    Example F2= 1000.00 MHZ (Now frequencies are set)

    Press MODE again

    Select DTF-SWR (DTF stands for distance to fault) press ENTER

    Press D1 to enter start distance

    D1= 0.0 m

    Press D2 to enter end distance (estimate the length of the cable, it should not be less)

    Example D2= 140 m (Now distance is set)

    To set up the amplitude, Press AMPLITUDE

    Select TOP and enter limit 1.5

    Now select BOTTOM and enter 1 (amplitude cannot be lesser than 1)

    Finally, to save the settings, press SAVE SETUP

    Check your saved settings for GSM 900 by RECALL SETUP

  • BTS CALIBRATION

    A.BOURI Page 6

    DRI TX CalibrationGSM900:

    Required Tools:

    Digital Power meter

    Power meter Sensor with

    Jumper cable and connectors

    Laptop with Procom Plus and TX Scripts (CTU1 & CTU2)

    MMI Cable for Procom terminal

    EQCP Cable for DRI access

    RSSI Cable for CTU1 clock reset Remarque 1: we will use our sitemaster (equipped with option 5) + Anritsu RF Wattmeter Power Monitor.

    Steps to perform for CTU1:

    Login to site through MCUF

    Check site id by disp_site command State Radios by State dri * * Check alarms at site disp_act Check equipage and antenna select of radios by disp_eq dri x y

  • BTS CALIBRATION

    A.BOURI Page 7

    Move to level 3 by using chg_l " command Login to BSC as follows

    Press Ctrl + n

    Write the command Rlogin 1 0114h (0114h to 0119h) Again press Ctrl + n , now you are in BSC, it can be verified by disp_site, BSC

    ID is 0

    Change to level 3

    Write the command Store to enable calibration data Now write disp_cal_data dri x y to check for Store Calibration Data:

    enabled

    Lock the sector by the command Lock dri x y, Repeat the same for all DRIs of the particular sector.

    While locking a radio, it must be noted to lock the DRI with RTF 0 at the last. RTF 0 of each sector contains BCCH

  • BTS CALIBRATION

    A.BOURI Page 8

    Making Power Measurements (ANRITSU S331A) Power measurement is accomplished using a broadband (1 MHz to 3 GHz)

    RF detector, P/N 5400-71N50. The power monitor displays the measured power in dBm or Watts. In our case we will display measurement in Watts

    Entering Power Monitor Mode

    Step 1. Press the POWER soft key, from the Main Menu Zeroing the Power Monitor

    Step 2. With no power applied to the DUT, press the ZERO soft key from the Power menu.

    Wait a few seconds while the Site Master accumulates samples of the quiescent power level.

    When complete, ZERO ADJ: ON is displayed in the message area.

    Remove MMI cable and login to DRI using RSSI cable o MMI ROM> tcu_clock 0 (reset clock to zero)

    Now login to DRI using EQCP cable

    Run the script Alarm_Off_TX, Alternate of script is to type the following commands:

    o EQCP> .gsmfw o EQCP> test o EQCP Test> bbh alarm off o EQCP Test> act c o EQCP Test> cspwr

    Adjust the power by giving offsets through U and D keys. For GSM 900, power should be 20 Watts (>=20 W & =16 W &

  • BTS CALIBRATION

    A.BOURI Page 9

    CTU1 TX Scripts ALARM_OFF_TX script for CTU1

    Press Alt+F3

    Select TX

    Select CTU 1

    Highlight Alarm_Off_Rx and click compile and Run

    SAVE_CAL_TX script for CTU1 Press Alt+F3

    Select TX

    Select CTU 1

    Highlight SAVE_CAL_TX and click compile and Run

  • BTS CALIBRATION

    A.BOURI Page 10

    Calibration of one radio (CTU1) is complete. Repeat the same process for all radios to be calibrated. After completing the last DRI, remove power meter from that DRI and connect back RF cable (All radios that are calibrated are still locked)

    Now login to BSC and Change level by chg_l Clear calibration data of all DRIs that are calibrated by the command

    Clear_cal_data dri x y

    Give hard reset to the radios (Must in CTU1)

    In service all radios by command: o Ins dri x y

    TX Calibration is complete, Note that offsets increasing 6 indicates that the particular CTU1 is faulty and may alter power again shortly.

    Check through disp_cal_data dri x y command that offsets have changed, if offset value is changed, then TX calibration of that DRI is successful.

    Steps to perform for CTU2 Unlike CTU1, CTU2 is calibrated in unlocked state, in a double density DRI, in-service one radio and keep associated radio locked

  • BTS CALIBRATION

    A.BOURI Page 11

    Login to site through MCUF

    Check site id by disp_site command State Radios by State dri * * Check alarms at site disp_act Check equipage and antenna select of radios by

    disp_eq dri x y

    Move to level 3 by using chg_l " command Login to BSC as follows Press Ctrl + n

    Write the command Rlogin 1 0114h (0114h to 0119h) Again press Ctrl + n , now you are in BSC, it can be verified by disp_site,

    BSC ID is 0

    Change to level 3 and Write the command Store to enable calibration data

    Now write disp_cal_data dri x y to check for Store Calibration Data: enabled

  • BTS CALIBRATION

    A.BOURI Page 12

    Lock the sector by the command Lock dri x y, repeat the same for all DRIs of the particular sector.

    While locking a radio, it must be noted to lock

    The DRI with RTF 0 at the last. RTF 0 of each sector contains BCCH

    Remove RF cable from dup and connect Power meter sensor in between.

    Position of sensor should be such that the arrow should direct towards the antenna.

    Connect the jumper cable with power meter and turn it on If power meter is showing values in dbm, convert them to Watt from the front display

    Now that the power meter is connected to the DUP, in service one radio and keep its associated radio locked, normally , in a CTU2 with two radios, the 1st one is in-serviced and the 2nd one is left locked (0 0 in-serviced and 0 1 locked)

  • BTS CALIBRATION

    A.BOURI Page 13

    Login to DRI using EQCP cable (no need to reset clock to 0 in case of CTU2). Run script TX_double or TX_single accordingly, depending weather theCTU2 is double density or single density

    Adjust the power by giving offsets through U and D keys. For GSM 900, power should be 20 Watts (>=20 W & =16 W &

  • BTS CALIBRATION

    A.BOURI Page 14

    Clear previous calibration data by command clear_cal_data dri x y Check that the calibration data is cleared by disp_cal_data dri x y It should show no calibration data

    Now finally, in-service the radios o ins dri x y

    Verifying successful If the offset value is changed after Power calibration (using this command),

    calibration successful

    If the frequencies (in hexa decimals) have changed after RX calibration calibration successful

  • BTS CALIBRATION

    A.BOURI Page 15