HUAWEI TECHNOLOGIES CO., LTD.
BTS3900E GSM
Installation Guide
Issue: 01Date: 2011-09-15
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
2/661
Installation Options of an AC Surge Protection Box
Installing the AC Surge Protection Box (on a pole)
Installing the Integrated Antennas of the BTS3900E
Powering on the BTS3900E
Appendix
Contents
Safety Information
Installation Tools
Installation Instruction
Installation Procedure for the DC BTS3900E
Space Requirements for the DC BTS3900E
Installation Modes for the DC BTS3900E
Installation Components
Installing the DC BTS3900E on a Wall
Installing the DC BTS3900E on a Pole
Installing the DC BTS3900E on an Angle Steel
Installing the DC BTS3900E on a U-Steel
Installing the DC BTS3900E on a L-Shaped Stand
Hoisting the DC BTS3900E and Mounting Brackets onto a tower...
Installing the DC BTS3900E Cables
Mounting and Grounding Requirements of the DC BTS3900E
Installing the Cables Between the APM30 and BTS3900E
Installing the Cables Between the APM30H(Ver.B) and BTS3900E
Installing the Cables Between the PS4890 and BTS3900E
Installing the Cables Between the EMU and the BTS3900E
Installing the Cables Between the Power2000 and the BTS3900E
Installing transmission cables in the public network...
Space Requirements for the AC BTS3900E
Installation Modes for the AC BTS3900E
Installing AC BTS3900E Cables
Copyright Huawei Technologies Co., Ltd. 2011. All rights reserved.
2
3
44
5
9
12
13
15
20
2021
25
27
34
36
37
38
3940
41
42
42
43
47
4849
52
54
55
Dimensions and Installation Clearance Requirements of an AC SurgeProtection Box.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
3/662
Following All Safety PrecautionsBefore any operation, read the instructions and precautions in this document carefully to minimize the possibilityof accidents.
The Danger, Caution, and Note items in the documents do not cover all the safety precautions that must be
followed. They only provide the generic safety precautions for operations.When operating Huawei products and equipment, you must comply with safety precautions and special safety
instructions related to corresponding equipment provided by Huawei. The safety precautions in the documentare related to only Huawei products. Huawei is not liable for any consequence that results from the violation ofuniversal regulations for safety operations and safety codes on design, production, and equipment use.
Complying with the Local Safety RegulationsWhen operating the device, comply with the local safety regulations. The safety precautions provided in thedocuments are supplementary. You must comply with the local safety regulations.
Qualified Personnel OnlyThe personnel in charge of installation and maintenance must be trained and master the correct operating
methods and safety precautions before beginning work.
Symbols
Safety of Personnel The high voltage power supply provides power for running the system. Direct contact with the high voltagepower supply or contact through damp objects may result in fatal danger.
Non-standard and improper high voltage operations may result in fire and electric shock. In a thunderstorm, do not perform operations on high voltage and AC power supply facilities or on a steeltower and mast.
Ground the device before powering on the device. Otherwise, the personnel and device are in danger. Power off the device before performing operations on the power supply equipment. High power radio-frequency signals are harmful to human body. Before installing or maintaining an antenna
on a steel tower or mast with a large number of transmitter antennas, the operator should coordinate with allparties to ensure that the transmitter antennas are shut down.
When handling optical fibers, do not stand close to, or look into the optical fiber outlet with unaided eyes. Protect yourself when drilling holes. Flying dust may hurt your eyes or you may inhale the dust. Power off the batteries before connecting the cables to the batteries. Otherwise, casualties may occur. When working at a height, be cautious about falling objects.
Device Safety Check the electrical connection of the device before operation and ensure that the device is reliably grounded. The static electricity generated by the human body may damage the electrostatic sensitive components onthe circuit board, such as the large-scale integrated circuit (LIC). Wear an ESD wrist strap or ESD gloves when
performing the operation. When working on batteries, take measures to prevent short circuits in the batteries and electrolyte spill/loss.The electrolyte may erode metal and boards, or even cause rust of the equipment or short circuits in the boards.
When the equipment is unpacked, it must be powered on in 24 hours. The maximum duration of the power-off state of the equipment is 24 hours during maintenance.
Safety Information
Indicates a hazard with a high level of risk, which if not avoided, will result in death or
serious injury.DANGER
WARNING
CAUTION
TIP
NOTE
Indicates a hazard with a medium or low level of risk, which if not avoided, could result
in minor or moderate injury.
Indicates a potentially hazardous situation, which if not avoided, could result in
equipment damage, data loss, performance degradation, or unexpected results.
Indicates a tip that may help you solve a problem or save time.
Provides additional information to emphasize or supplement important points of the
main text.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
4/663
Installation Tools
Phillips screwdriver
(M2 to M6)Flat-head screwdriver
(M2 to M6)
Knife Rubber mallet
Crimping pliers
for power cables CleanerWire cutter for
power cables
Torque screwdriver
(14 kgfcm)Inner hexagon wrench Wire stripper
Percussion drill (14) Heat gun Level bar
Multimeter Long measuring tape
Combination wrench
Marking pen
Wrench(with the diameter of at least 32 mm)
(21mm to 21mm) for pole installation(17mm to17mm) for wall installation
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
5/664
Installation Instruction
BTS3900Es are classified into DC and AC BTS3900Es. The procedure for installingDC and AC BTS3900Es are provided in this document.
The RF port at the bottom of the BTS3900E does not have load capacity. Do not place the BTS3900E on theground on its bottom during installation.
When you perform this operation, you need to place the foam pads or paper under the BTS3900E to avoidany damage to the shell.
Installation Procedure for the DC BTS3900E
Install the
BTS3900E on a pole
Install the
BTS3900E on a wall
Install the BTS3900E
on a U-steel
Install the BTS3900E
on an angle steel
Prepare for the installation
Start
End
Power on the BTS3900E
Install BTS3900E cables
Install the BTS3900E
on a L-shaped stand
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
6/665
Space Requirements for the DC BTS3900E
a Dimensions of a Single DC BTS3900E
Recommended Clearance fora Single DC BTS3900E
c Minimum Clearance for asingle DC BTS3900E
Minimum Installation Clearance for a Single DC BTS3900E
Installed on a Tower
268mm
485mm
130mm
500mm
300mm 200mm
300mm
300mm
200mm
400mm
280mm
280mm
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
7/666
Space Requirements for the DC BTS3900E
e Recommended Clearance for Multiple DC BTS3900Es Installedon a Wall in Standard Mode
f Minimum Clearance for Multiple DC BTS3900Es Installed ona Wall in Standard Mode
g Recommended Clearance for Multiple DC BTS3900EsSide-Mounted on a Wall
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
8/667
Space Requirements for the DC BTS3900E
Recommended Horizontal
Spacing Between DC
BTS3900Esi Minimum Horizontal Spacing
Between DC BTS3900Es
j Recommended VerticalSpacing Between DCBTS3900Es
k Minimum Vertical SpacingBetween DC BTS3900Es
h
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
9/668
Space Requirements for the DC BTS3900E
l Recommended Clearance for Multiple Centralized DCBTS3900Es on a Pole
m Minimum Clearance for Multiple Centralized DC BTS3900Eson a Pole
500mm
300mm
200mm
300mm
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
10/669
Installation Modes for the DC BTS3900E
a Installing the BTS3900E on a Wall
On a wall
When BTS3900Es are installed on awall, the specifications of the wall are
as follows: The wall is able to bear weight fourtimes that of the BTS3900E. The
weight of a DC BTS3900E is 13.5kg.The weight of an AC BTS3900E is17kg.
When the BTS3900E is installed onthe wall, the fastening torque of theexpansion bolt should be 30Nm.
Ensure that the expansion bolt areproperly tightened and there is nocrack on the wall.
The brackets cannot be combinedwhen BTS3900Es are installed on awall, as shown in the figure on the right.
b Installing the BTS3900E on a Pole
A maximum of two BTS3900Es can beinstalled on a pole with the diameter of
60mm to 76mm. When more than two BTS3900Es areinstalled on a pole in centralized mode,
the diameter of the pole must range from76mm to 114mm.
Diameter of a poleOn a pole
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
11/6610
Installation Modes for the DC BTS3900E
c Installing the BTS3900E on an angle steel
d Installing the BTS3900E on a U-steel
BTS3900E
Angle steel10
It is recommended that only one BTS3900Ebe installed on angle steel.
The vertical deviation angle of angle steelmust be less than or equal to 10 degrees, asshown in the preceding figure.
On an angle steel
Diameter of an
angle steel
BTS3900E
U-steel10
On a U-steel Diameter of a U-steel It is recommended that only one BTS3900Ebe installed on U-steel.
The vertical deviation angle of U-steel mustbe less than or equal to 10 degrees, asshown in the preceding figure.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
12/6611
Installation Modes for the DC BTS3900E
e Installing the BTS3900E on a L-shaped stand
On a L-shaped stand
In the scenario where a cable rack is more than 2 m above thefloor (hereinafter referred to as the height-unrestricted
scenario), the BTS3900Es are installed on beam 1 and beam 3by default.In the scenario where a cable rack is 1.8 m to 2 m above the
floor (hereinafter referred to as the height-restricted scenario),the BTS3900Es are installed on beam 2 and beam 4 by default.If the BTS3900E needs to be installed on the L-shaped stand,
only the main bracket is required.BTS3900E can be installed on an L-shaped stand in standardinstallation mode, reverse installation mode, or side installation
mode.
Height-restricted scenarioHeight-unrestricted scenarioCable
rackCable
rack
Beam 2Beam 1
Beam 3Beam 4
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
13/6612
Installation Components
Thefront and rear view ofa BTS3900E
Brackets for Installing
the BTS3900Eb
To protect the RF ports on the bottom of theBTS3900E, remove the dustfree caps when
installing RF cables.
Front view Rear view
The brackets are used for installing the BTS3900Eon a pole, wall, angle steel, or U-steel.
When installing the main mounting bracket, ensure
that the contact piece on the bracket is securelyfixed.
Cover plate Attachment plate Hoist clamp on themain mounting bracket
Main mounting bracket
Dual-nut bolt assembly
Auxiliarymounting bracket
Expansion bolt
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
14/6613
Installing the DC BTS3900E on a Wall
After the expansion bolt is removed, dispose of the plastic tube.Do not hammer the bolt into the expansion tube completely and leave20 mm to 30mm of the bolt outside the wall.
It is recommended that the bottom of the auxiliary
mounting bracket is 1200mm to 1600mm above the
ground.
Place the auxiliary mountingbracket on the wall at the
installation position, adjust the levelness of the bracket, and
then mark the anchor points by using a marking pen.
a
Drill holes at the anchor points and install the expansion
assemblies.
20~30mm
Bolt M10x65
Flat washer 10
Spring washer 10
Expansion tube
Plastic tube
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
15/6614
Installing the DC BTS3900E on a Wall
Fix the auxiliary mounting
bracket on the wall securely.
Install the BTS3900E on the main mounting bracket until
the BTS3900E snaps shut.
Fix the auxiliarymounting bracket on the
expansion bolts andthen tighten the bolts byusing a combination
wrench (17mm-17mm). The auxiliary mountingbracket must be
installed between theflat washer of theexpansion bolt and the
wall.
Install the main mounting
bracket.
Choose standard or reverseinstallation mode according to
site survey. This figure is basedon the standard installation mode.When the BTS3900E is installed
on the wall, ensure that the anglebetween the BTS3900E and the
wall is less than 2 degrees asshown in the preceding figure.
Wall
BTS3900E
2
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
16/6615
Install the main mounting bracket. Then, install the auxiliary
mounting bracket between the nuts of the dual-nut bolt
assembly on the main mounting bracket.
a
40Nm
Use an adjustable wrench to
tighten the nut by the
fastening torque 40Nm.
In this way, the main andauxiliary mounting brackets
are secured on the pole.
bInstall the BTS3900E on the
main mounting bracket untilthe BTS3900E snaps shut.
c
Tighten the two dual-nut bolt assemblies alternatively. After the brackets are
secured properly, measure the spacing between the main and auxiliarymounting brackets on both sides and ensure that the spacing is the same onthe two sides.
Installing the DC BTS3900E on a Pole
(a single BTS3900E)
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
17/6616
Install the first BTS3900E. For details, see page 15.a
Install the other main mounting bracket on the auxiliary
mounting bracket to secure the second BTS3900E.
Reinstall the attachment plate on the back and cover plate on
the front of the second BTS3900E to interchange their positions.
Installing the DC BTS3900E on a Pole
(two BTS3900Es)
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
18/6617
Mount the second BTS3900E on the main mounting bracket.d
When you install two BTS3900Es in back-to-back mode,ensure that the cabling cavities of these two BTS3900Es face
the same direction.
Installing the DC BTS3900E on a Pole
(two BTS3900Es)
Standard installationReverse installation
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
19/6618
Reinstall the attachment plate on the back and cover plate on
the side of a BTS3900E to interchange their positions.a
Mount the BTS3900E on
the main mounting bracket.
Install the main mounting
bracket of the second
BTS3900E.
c
Installing the DC BTS3900E on a Pole
(multiple BTS3900Es)
side installation
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
20/6619
Install the main mounting bracket of the third BTS3900E, and
mount the third BTS3900E on the main mounting bracket.e
The layout of three BTS3900Es installed ona pole must be symmetrical.
Mount the second BTS3900E on the main mounting bracket.
Installing the DC BTS3900E on a Pole
(multiple BTS3900Es)
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
21/6620
Installing the DC BTS3900E on an Angle Steel
Installing the DC BTS3900E on a U-Steel
The procedure for installing the BTS3900E on an angle steel isthe same as that on a pole.
When the BTS3900E is installed on an angle steel, the mainmounting bracket and auxiliary mounting bracket can be installedon only the position as shown in the preceding figure.
The procedure for installing the BTS3900E on a U- steel is the same as that on a pole. When the BTS3900E is installed on a U-steel, the main mounting bracket and auxiliary
mounting bracket can be installed on only plane A, B, C, or D, as shown in the precedingfigure.
Angle steel
Plan view
Plan view
U-steel
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
22/6621
Installing the DC BTS3900E on a L-shaped stand
(Height-unrestricted scenario)
Install the main mounting bracket.
Label
Spring washer
Rubber washer
Link the M6 OT terminal at one end of the PGND cable to the wiring
terminal at the bottom of the BTS3900E, and leave the other end idle.
If the BTS3900E needs to be installedon the L-shaped stand, only the main
mounting bracket is required.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
23/6622
Installing the DC BTS3900E on a L-shaped stand
(Height-unrestricted scenario)
Install the BTS3900E on the main mountingbracket.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
24/6623
Installing the DC BTS3900E on a L-shaped stand
(Height-restricted scenario)
Install the main mounting bracket.
Link the M6 OT terminal at one end of the PGND cable to the wiring
terminal at the bottom of the BTS3900E, and leave the other end idle.
Label
Spring washer
Rubber washer
Before installing the main bracket in theheight-restricted scenario, you must
use a finger to push the rubber cap out.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
25/6624
Installing the DC BTS3900E on a L-shaped stand
(Height-unrestricted scenario)
Install the BTS3900E on the main mountingbracket.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
26/6625
The DC BTS3900E support installation on a tower, whereas the AC BTS3900E does not support installationon a tower.
Before installing a BTS3900E on a tower, bind the BTS3900E and mounting brackets and then hoist them ontothe tower. The BTS3900E can be installed on a pole, angle steel, or U-steel.When installed on a tower, only one BTS3900E can be installed in standard mode or reverse mode. Two
BTS3900Es cannot be installed on the side or on a pole in back-to-back mode, and the brackets for more thantwo BTS3900Es cannot be combined.
Bind the BTS3900E and mounting brackets properly using a
lifting sling.
Bind the BTS3900E by leading the lifting sling along the bottom
of the attachment plate and through the BTS3900E handle. Then,
bind mounting brackets to the lifting sling and bind the
BTS3900E handle to the traction sling.
b
The cross-sectional area of the lifting sling and traction sling isaround 20 mm, not more than 25 mm. In addition, the slings can
bear the weight four times more than that of the BTS3900E.When hoisting the BTS3900E and mounting brackets up to thetower, prevent the BTS3900E from colliding with the tower.
When hoisting the BTS3900E up to the tower, bind the E1 cable,FE cable, and alarm cable with outdoor black anti-ultraviolet cableties.
Do not hoist the BTS3900E by thehandle only, as shown in the figure
on the left. Hoist the BTS3900E to the towerbefore it is installed on the pole,
angle steel, or U-steel.
Hoisting the DC BTS3900E and Mounting Brackets
onto a tower
Lifting sling
Tractionsling
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
27/6626
Hoist the BTS3900E and mounting brackets onto the tower.
1.Installers A climb onto the tower. Then, installer Afixes the pulley to the support of the tower platform
and leads the lifting sling through the fixed pulley.
2.Installer C uses a lifting sling to bind theBTS3900E and mounting brackets as shown in the
preceding figure and then tie a knot in the tractionsling at the handle of the BTS3900E.3.Installer B pulls the lifting sling, and at the same
time, installer C pulls the traction sling away fromthe tower to prevent the BTS3900E and mountingbrackets from colliding with the tower.
4.Installers A hold the BTS3900E and mountingbrackets and untie the slings.
Hoisting the DC BTS3900E and Mounting Brackets
onto a tower
Lifting sling Tractionsling
Fixed pulley
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
28/6627
abc
d
eg
h
if
Installing the DC BTS3900E Cables
Cable Connections of a Single DC BTS3900E
Bottom
Install the PGND
cable
Install the RF jumper
(interconnect jumperis optional)
Install the power cable
Install the transport
cable
Install the alarm
cable(optional)
Start
End
When installing the power cable, you must insulate the bare wires and screwdriver if the power cable must beled through the power cabinet of the operator. This prevents short circuit caused by the contact of the bare wire
or screwdriver and other equipment. When opening cabling cavity, do not impose pressure on the cover of the cabling cavity.
External powersystem
External device
Transmission device
Antenna
USB
Maintenance PC
Cable Connections of a DC BTS3900E
Sequence of Installing the Cables
(a) Alarm cable (b) Ethernet cable
(for transmission)
(c) DC
power cable
(d) Ethernet cable
(for maintenance)
(e) RF jumper (f) Feeder
(g) PGND cable (h)E1 cable (i) USB
E1/T1
RET/TST
MON
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
29/6628
Installing the DC BTS3900E Cables
Externalpower system
Ante
nna
When the BTS3900E uses DC power supply, it
supports the cascading power supply mode.Amaximum of three BTS3900Es can be cascadedin the chain topology.When installing the signal cables for combined
cabinets, ensure that port SFP0 of the maincabinet is connected to port SFP0 of the extensioncabinet, or port SFP1 of the main cabinet of is
connected to port SFP0 of the extension cabinet. Port SFP0 of the main cabinet is preferentiallyused.
ExtensionCabinet Main Cabinet
Cable Connections of Combined DC BTS3900Es
(a) RF jumper (b) Signal cable for
combined DC BTS3900E
(c) DC power cable (d) PGND cable
(e) PGND cable for cascaded BTS3900Es
abc
de
Cable Connections of
Combined DC BTS3900Es
Ante
nna
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
30/6629
Installing the DC BTS3900E Cables
Waterproof tapePVC insulating
tape
View of the DC BTS3900E Cables
Press the strap on the exposed shielding layer of the powercable tightly. The OT terminal is pressed under the copper bar.
Ensure that the lower edge of the exposed shielding layer doesnot exceed the position shown in the figure on the right. The shielding layer of the other end of the power cable should
be grounded. To avoid sharp bending, the optical cable must be pressed bythe strap next to the power cable during the optical cable
installation.
Wrap the joint of the RF jumper with the waterproof tape andthen with PVC insulating. The tape is wrapped spirally upwards,
downwards, and then upwards again in three layers. For everytwo adjacent tape layers, the tape on the upper layer overlapsabout half the width of the tape on the lower layer.
When removing the SFP high-speed cable, you need togently pull or push the puller according to the terminal type.
RF jumper
Power cable
Shielding layer ofthe power cable
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
31/6630
Installing the DC BTS3900E Cables
Wiring post on the external power system
ANTA_TX/RX port or ANTB_RX port at the bottom of the
BTS3900E
PGND cable: Wiring post on the protection grounding bar.
PGND cable between cascaded BTS3900Es: Grounding
bolt at the bottom of another cascaded BTS3900E.
Grounding screw at the bottom of the BTS3900E
List of Cables
Connected toConnector TypeCable
OT terminal
OT terminalPGND cable (PGNDcable between
cascaded BTS3900Es)
Feeder or antennaDIN male connector
DIN male connector
Antenna jumper
North American standard : OT terminal for the blue wire
to NEG (-)0 port in the cabling cavity of the BTS3900E
and OT terminal for the black wire to the RTN (+)0 port
European standard: OT terminal for the blue wire to NEG
(-)0 port in the cabling cavity of the BTS3900E and OT
terminal for the brown wire to the RTN (+)0 port
Two OT terminalsDC power cable
Bar wires
DC power cable
for cascaded
modules
OT terminal
OT terminal
North American standard: connect the OT terminal of the
blue cable to the NEG (-)1 port and the OT terminal of the
black cable to the RTN (+)1 port on the cabling cavity of the
upper-level BTS3900E
European standard: connect the OT terminal of the blue
cable to the NEG (-)1 port and the OT terminal of the black
cable to the RTN (+)1 port on the cabling cavity of the
upper-level BTS3900ENorth American standard: connect the OT terminal of the
blue cable to the NEG0(-) port and the OT terminal of the
black cable to the RTN0(+) port on the cabling cavity of the
lower-level BTS3900E
North American standard: connect the OT terminal of the
blue cable to the NEG0(-) port and the OT terminal of the
black cable to the RTN0(+) port on the cabling cavity of the
lower-level BTS3900E
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
32/6631
Installing the DC BTS3900E Cables
Connect the connectors labeled with 1A and 1B to portSFP0 or port SFP1 in the cabling cavity of the main
cabinet
Connect the connectors labeled with 2A and 2B to port
SFP0 in the cabling cavity of the extensioncabinet
Inter-BTS3900E signal
cable
SFP0 or SFP1 port in the cabling cavity of the main
cabinet
List of Cables
Connected toConnector TypeCable
CPRI Optical Cable:DLC connector
SFP High Speed Signal
Cable: SFP200 male
connector
CPRI Optical Cable
SFP High Speed Signal
Cable
MON port at the bottom of the BTS3900E
Bar wires
E1/T1 port on the BTS3900E
Corresponding auxiliary devices
Bar wires Alarm signal port on the external device
DB9 female connector
Ethernet cable
RJ-45 connector
RJ-45 connector
Transmission: FE port in the cabling cavity of the BTS3900E
Maintenance: ETH port in the cabling cavity of the BTS3900E
PoE power supply: FE port in the cabling cavity of the
BTS3900E
Transmission: port on the corresponding transmission device
Maintenance: Ethernet port on the PC where the SMT is
installed
PoE power supply: microwave transmission device
DB15 male connector
Alarm cable
E1 cable
(75 ohm/120 ohm)
SFP0 port in the cabling cavity of the extension cabinet
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
33/6632
Cabling cavity
Cover plate of
the cabling cavity
Label for makingpower cables
Cable trough forpower cables
Installing the DC BTS3900E Cables
Opening the cover plate
of the cabling cavity
e Introduction to the cabling cavity
Make power cables by referring to thelabel on the cover plate of the cabling
cavity. For details, see page 56 and 56. After the cables are installed, thewaterproof filler should be installed in
the unused cable trough.The installation method of the cablingcavity of the AC BTS3900E and the
settings of DIP switches on the ACBTS3900E are similar to those of theDC BTS3900E.
Waterproof filler
Closing the cover plate
of the cabling cavity
The screws on the cover plate are tightened in theorder shown in the preceding figure.
Take proper ESD protection measures, for example,
wear ESD gloves, to prevent electrostatic damage tothe boards, modules, or electronic components.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
34/6633
Installing the DC BTS3900E CablesSetting DIP Switchesh
When a 75-ohm cable is used for the BTS3900E,the RX end is not grounded by default.
Bits 1 and 2 are used to specify whether theBTS3900E is a basic module or an extensionmodule and the transmission mode.
When bits 1 and 2 are set to ON, bits 3 and 4
can be used to specify the grounding state of the75-ohm E1 transmission.
Settings of DIP switches on the BTS3900E
Switch Status Description
1 2
ON ON Main cabinet,75-ohm E1 mode
OFF ON Main cabinet,120-ohm E1 mode
ON OFF Main cabinet,T1 mode
OFF OFF Extension cabinet mode
Switch Status Description
3 ON Channel 2 of 75-ohm E1,RX end grounded
OFF Channel 2 of 75-ohm E1RX end not grounded
4 ON Channel 1 of 75-ohm E1RX end grounded
OFF Channel 1 of 75-ohm E1RX end not grounded
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
35/6634
If Huawei does not provide the transmission devices, the interconnection ports of
the transmission devices should meet the following requirements:
The surge protection level of the FE port should be greater than or equal to
7.5kA (8/20us) in all-to-ground common mode. Otherwise, a surge protection unit
should be installed near the FE port. The surge protection level of the E1 port should be greater than or equal to 3kAin pair-to-ground differential mode or 5kA in pair-to-ground common mode.
Otherwise, a surge protection unit should be installed near the E1 port.
Tower Mountinga
The shielding layer of a DC cable must be grounded properly to the maintenance cavity of the BTS3900E. Therefore,
external grounding is not required on the tower.
The shielding layers of the E1 cable and alarm cable are grounded on the BTS side with connectors. Therefore, grounding
clips are not required on the tower.
If cable clips, cable ties, or pig tail clips are used to ground the cables on the power supply device and transmission device
side, grounding clips are not required.
4. Grounding Requirements of External Cables
1. Requirements of BTS3900E Installation and Port Surge Protection
The BTS3900E and its auxiliary devices must be installed within the 45 protection
angle of the lightning rod. The BTS3900E must be grounded to the nearest grounding point on the tower
(within 1m from where the BTS3900E is installed).
None of the external ports of the BTS3900E require external surge protection units.
The BTS3900E and its transmission and power supply devices must be connected
to the same grounding system and share the grounding grid of the site.
2. Recommendations for Transmission Device Protection
Mounting and Grounding Requirements of the DC BTS3900E
Grounding Point (Power Supply
Device and Transmission Device
Located in the Equipment Room)
Grounding Point (Power Supply
Device and Transmission Device
Sharing an Outdoor Cabinet)
Description
FE cable Points 1 and 3 Points 1 and 4 At points 1 and 2, use grounding clips to ground
the shielding layer of a cable by connecting the
PGND cable to the nearest grounding bar of the
tower.
At point 3, use grounding clips to ground the
shielding layer o f a cable by connecting the PGND
cable to the nearest grounding bar of the feeder
window.
At point 4, use grounding clips to ground the
shielding layer o f a cable by connecting the PGND
cable to the nearest grounding bar of the cabinet.
For details about how to install grounding clips,
see page 64.
Point 2 (The distance between the
equipment room and the tower is
more than 10m.)
Point 2 (The distance between the
cabinet and the tower is more than
10 m.)
DC power
cable
Point 3 Point 4
Point 2 (The distance between the
equipment room and the tower is
more than 10m.)
Point 2 (The distance between the
cabinet and the tower is more than
10 m.)
E1 cable
and alarm
cable
Point 3 Point 4
3. Grounding points description
Point 1: within 1m of where the BTS3900E is installedPoint 2: within 1m of the bend in the cable leading away
from the towerPoint 3: over the grounding bar in front of the feeder
window
Point 4: at the inlet of an outdoor cabinet or inside the
cabinet
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
36/6635
If Huawei does not provide the transmission devices, the interconnection
ports of the transmission devices should meet the following requirements: The surge protection level of the FE port should be greater than orequal to 7.5kA (8/20us) in al l-to-ground common mode. Otherwise, a
surge protection unit should be installed near the FE port.
The surge protection level of the E1 port should be greater than or equal
to 3kA in pair-to-ground differential mode or 5kA in pair-to-groundcommon mode. Otherwise, a surge protection unit should be installed
near the E1 port.
Rooftop Mountingb
The shielding layer of a DC cable must be grounded properly to the maintenance cavity of the BTS3900E. Therefore,
external grounding is not required on the rooftop. The shielding layers of the E1 cable and alarm cable are grounded on the BTS side with connectors. Therefore, grounding
clips are not required on the rooftop. Insulating tapes or L-shaped plastic pipes must be used to protect cables from damage.
If cable clips, cable ties, or pig tail clips are used to ground the cables on the power supply device and transmission device
side, grounding clips are not required.
4. Grounding Requirements of External Cables
1. Requirements of BTS3900E Installation and Port Surge Protection
The BTS3900E and its auxiliary devices must be installed within the 45
protection angle of the lightning rod. The BTS3900E must be grounded to the nearest metal pole or rooftop
surge protection belt (within 1m from where the BTS3900E is installed).
None of the external ports of the BTS3900E require external surge
protection units.
The BTS3900E and its auxiliary devices are installed on the same rooftop.
External cables must be routed in lightning-free areas and cannot beshort-circuited to the surge protection belt on the rooftop or to the external
conductors on the building.
2. Recommendations for Transmission Device Protection
Mounting and Grounding Requirements of the DC BTS3900E
Grounding Point (Power
Supply Device and
Transmission Device
Located in the Equipment
Room)
Grounding Point (Power
Supply Device and
Transmission Device
Sharing an Outdoor
Cabinet on the Rooftop)
Description
FE cable Points 1 and 3 Points 1 and 4 At points 1 and 5, use grounding clips to ground the
shielding layer of a cable by connecting the PGND cable
to the nearest surge protection belt on the rooftop.
At point 3, use grounding clips to ground the shielding
layer of a cable by connecting the PGND cable to the
nearest grounding bar of the feeder window.
At point 4, use grounding clips to ground the shielding
layer of a cable by connecting the PGND cable to the
nearest grounding bar of the cabinet.
For details about how to install grounding clips, see
page 64.
Point 5 (The length of the cable
routed horizontally on the
roof top is more than 20m.)
-
DC power cable,
E1 cable, and
alarm cable
Point 3 Point 4
Point 5 (The length of the cable
routed horizontally on the
roof top is more than 20m.)
-
3. Grounding points description
Point 1: within 1m of where the BTS3900E is installedPoint 3: over the grounding bar in front of the feeder windowPoint 4: at the inlet of an outdoor cabinet or inside the cabinet
Point 5: on the roof edge within 1m of the bend of the cable ladder
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
37/6636
APMI
PDU
USLP2
Powercable
Alarm cable
Strip the jacket of the power cable for a smallpart, press the exposed shielding layer on the
strap, and then connect the PGND cable on thestrap to the nearest grounding bolt on the sidein the APM30.
The power cable is connected to one of theLOAD4 to LOAD9 terminals of the PDU.
Shielding layerfor the power
cable (25mm)
Installing the Cables Between the APM30 and
BTS3900E
PowercableAlarm
cable
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
38/6637
Add RJ-45 connectors to the four wires labeled PSU485 TX-, PSU485 TX+, PSU485 RX-, and PSU485 TX-of the alarm cable and cut off other wires. Then, link the RJ-45 connectors to the COM_IN port on the HEUA
or on the CMUA.Strip the jacket of the power cable for a small part, press the exposed shielding layer on the strap. Fordetails, see page 36.
Installing the Cables Between the APM30H (Ver.B)and BTS3900E
COM_IN
EPS
LOAD813
Powercable
Alarmcable
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
39/6638
PS4890 BTS3900EaBTS3900E
Shielding layerfor the power
cable
LOAD0
PS4890 USLP2 Board BTS3900Eb
Shielding layerfor the power
cable
Power Cable
Alarm cable
Power cable
Alarm cable
PMU
Installing the Cables Between the PS4890 and
BTS3900E
LOAD0USLP2
PMU
BTS3900E
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
40/6639
Pin on the
DB15
Connector
Wire Type Wire Color Signal
Type
X1.11 Twisted paircable
Red TX-
X1.12 Blue TX+
X1.13 Twisted paircable
Red RX-
X1.14 Orange RX+
Pin on the DB9
Connector
Wire
Type
Wire
Color
Signal
Type
X1.7 Twisted paircable
Orange TX-
X1.2 White andorange
TX+
X1.6 Twisted paircable
White andblue
RX-
X1.1 Blue RX+
For the description of the pin on theDB15 connector, see page 55.
Installing the Cables Between the EMU and the
BTS3900E
DB15connector
DDF
DB9connector
EMUalarm cable
BTS3900Ealarm cable
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
41/6640
Ensure that all the MCBs are set toOFF before the cable connection.
The four wires of the BTS3900E alarm cable marked with PSU 485 are connected to the J18 portaccording to the cable sequence in the preceding figure.
The signal cables of the BTS3900E alarm cable marked with SWITCH and GND can be connectedto the door status monitoring cable or other dry contact alarm cables through interconnectionterminals.
The interconnection terminals are placed in Power 2000.
Installing the Cables Between the Power2000 and
the BTS3900E
Powercable
Dry contact
Alarmcable
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
42/6641
Eudemon 200E-C
Eudemon 200E-C
Connect the FE signal cable that is led out from the FE port on the cabling cavity panel of the BTS3900E tothe INSIDE FE0 port of the UFLP on the SLPU, and then connect the FE signal cable that is led out from the
OUTSIDE FE0 port on the UFLP to the port on the 1FE electric interface card of the Eudemon 200E-C.The FE signal cables on the BTS3900E side and the SLPU side are grounded through grounding clips. Thelength of the FE cables between the BTS3900E and the grounding clips and that between the SLPU and the
grounding clips is within 1m.For details about how to install the Grounding Clip, see page 64.
In the public network transmission scenario, the connection betweenthe AC-powered BTS3900E and the Eudemon 200E-C and that
between the DC-powered BTS3900E and the Eudemon 200E-C are thesame.Connect the FE signal cable that is led out from the FE port on the
cabling cavity panel of the BTS3900E to the port on the electricinterface card of the Eudemon 200E-C.
Indoor Installation of the BTS3900E
Outdoor Installation of the BTS3900E
Installing transmission cables in the public network
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
43/6642
Space Requirements for the AC BTS3900E
The installation scenarios and modes of the AC BTS3900E are the same as those of the DC BTS3900E. Fordetails, see pages 9 to 24.
The AC BTS3900E does not support installation on a tower.
Installation Modes for the AC BTS3900E
Dimensions of a Single AC BTS3900E
The space requirements for the AC BTS3900E is the same as that of the DC BTS3900E.
370mm
485mm
130mm
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
44/6643
Installing the AC BTS3900E Cables
Cable Connections of a Single AC BTS3900E
Bottom
When installing the power cable, you must insulate the bare wires and screwdriver if the power cable must beled through the power cabinet of the operator. This prevents short circuit caused by the contact of the bare wire
or screwdriver and other equipment. When opening maintenance cavity, do not impose pressure on the cover of the maintenance cavity.
USB
External powersystem
Anten
na
Maintenance PC
Alarm device
Transmission device
ab
c
d
e
f
g
h
i
Install the PGND
cable
Install the RF jumper
(interconnect jumper is
optional)
Install the power cable
Install the
transmission cable
Install the alarm
cable(optional)
Start
End
Sequence of Installing the Cables
Cable Connections of a AC BTS3900E
(a) Alarm cable (b) Ethernet cable
(for transmission)
(c) AC
power cable
(d) Ethernet cable
(for maintenance)
(e) RF jumper (f) Feeder
(g) PGND cable (h)E1 cable (i) USB
Surge protection box
E1/T1
RET/TST
MONPort for AC power input
RF port
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
45/6644
Installing the AC BTS3900E Cables
View of the AC BTS3900E Cables
The combined AC BTS3900Es do not
support cascading through power cables.
When the BTS3900E is installedoutdoors, the surge protection box for
AC power is required.
The two antenna ports and AC input power port on theAC BTS3900E must be wrapped with waterproof tape
and PVC insulating tape. For details, see page29.AC power cables use aeronautical connectors. Whenconnecting AC power cables, you must warp them with
PVC corrugated tubes and waterproof tapes.
External power system
Ante
nna
Ante
nna
a
b c
de
Cable Connections of Combined AC BTS3900Es
(a) RF jumper (b) Inter-BTS3900Esignal cable
(c) AC power cable (d) PGND cable
(e) Equipotential cable
Waterproof/PVC
insulating tape
ExtensionCabinet Main Cabinet
Surge protection box
Corrugated pipe Power cable
RF jumper
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
46/6645
Installing AC BTS3900E Cables
3-pin round connectorAC power cable
(outdoor AC BTS3900E
List of Cables
Equipotential cable
(outdoor AC BTS3900E)
Grounding bar on the surge protection box
AC surge protection box
PWR port at the bottom of the BTS3900E
Connected toConnector TypeCable
OT terminal
OT terminalPGND cable (PGNDcable between
cascaded BTS3900Es)
OT terminal
OT terminal
Feeder or antennaDIN male connector
ANTA_TX/RX port or ANTB_RX port on the
BTS3900E
DIN male connector
Antenna jumper
OT terminal
PGND cable: Wiring post on the protection
grounding bar.
PGND cable between cascaded BTS3900Es:
Grounding bolt at the bottom of another
cascaded BTS3900E.
Grounding screw at the bottom of the BTS3900E
Grounding screw at the bottom of the BTS3900E
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
47/6646
Installing AC BTS3900E Cables
E1 cable
(75 ohm/120 ohm)
Ethernet cable
RJ-45 connector
RJ-45 connector
Connected toConnector TypeCable
DB15 male connectorAlarm cable
Bar wires
Bar wires
DB9 female connector
Transmission: port on the corresponding transmission device
Maintenance: Ethernet port on the PC where the SMT is installed
PoE power supply: microwave transmission device
Transmission: FE port in the cabling cavity of the BTS3900EMaintenance: ETH port in the cabling cavity of the BTS3900E
PoE power supply: the FE port in the cabling cavity of the
BTS3900E
Alarm signal port on the external device
MON port at the bottom of the BTS3900E
E1/T1 port on the BTS3900E
Corresponding auxiliary devices
PWR port at the bottom of the BTS3900E3-pin round connector
Bar wires
AC power cable
indoor AC
BTS3900E)
External power system
Inter-
BTS3900E
signal cable
Connect the connectors labeled with 1A and 1B to port SFP0
or port SFP1 in the cabling cavity of the main cabinet.
Connect the connectors labeled with 2A and 2B to port SFP0
in the cabling cavity of the extension cabinet.
SFP0 or SFP1 port in the cabling cavity of the main cabinet
SFP0 port in the cabling cavity of the extension cabinet
CPRI Optical Cable :
DLC connector
SFP High Speed Signal
Cable: SFP200 male
connector
CPRI Optical Cable
SFP High SpeedSignal Cable
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
48/664747
Dimensions of an AC
surge protection boxa bDimensions and Installation Clearance Requirements
of an AC Surge Protection Box
Recommended clearance for
an AC surge protection box
c Minimum clearance foran AC surge protection box
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
49/6648
a bInstallation Options of an AC Surge Protection Box
AC surge protection box
installed on a pole
AC surge protection box
installed on a wall
The procedure for installing an AC surge protection box on a wall is the same as that for installing a BTS3900Eon a wall. For details, see Installing the DC BTS3900E on a Wall.
Following is the procedure for installing an AC surge protection box on a pole.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
50/6649
Installing the AC Surge Protection Box (on a pole)
Install an AC surge protection box on a pole.
Loosen the screws on the AC surge protection box using the M4
phillips screwdriver and open the cover plate. Then, remove the
thread-lock sealing nut from the PG connector of the surge
protection box, and store waterproof blocks properly.
b
Do not use the removed thread-lock sealing nut of the PG connector with the thread-lock sealing nuts on other
surge protection boxes.
1.Loosen the screw on the clamp using anM4 Phillips screwdriver.
2. Lead the clamp through the gap betweenthe rear cover plate and the case of thesurge protection box.
3.Circle the clamp around the pole, and thentighten the screw on the clamp.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
51/6650
Installing the AC Surge Protection Box (on a pole)
Glide the thread-lock sealing nut and then the PG connector
over the power cable. Connect power cables to the AC surge
protection box.
c
Close the cover plate of the surge protection box and tighten
the screw to 1.4Nm using an M4 Phillips screwdriver.
Ensure that the insulation layer of eachpower cable is fastened using clips.
1. Lead the power cable between the surge protection
box and the external power device through the PG
connector labeled IN. Connect the OT terminals of the
blue, brown, and yellow/green core wires to the Lin,Nin, and GND ports on the surge protection box
respectively.
2. Lead the power cable between the BTS3900Eand the AC surge protection box through the PG
connector labeled OUT. Connect the OTterminals of the blue, brown, and yellow/green
core wires to the Nout, Lout, and GND ports onthe surge protection box respectively.3.Tighten the thread-lock sealing nut, and thenuse a wrench to tighten the PG connector to
ensure it is waterproofed properly.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
52/6651
Installing the AC Surge Protection Box (on a pole)
Wrap waterproof tape and then PVC insulation tape around both
ends of each power cable and connectors between corrugated
pipes.e
Install the PGND cable between the BTS3900E and the AC surge
protection box.
Corrugated pipes Corrugated pipes
PGND cableEquipotential cable
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
53/6652
Installing the Integrated Antennas of the BTS3900E
Installing Directional Antennas
ANTA_TX/RX
M63.0
45Nm
M30
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
54/6653
Installing Omni-Directional Antennas
Installing the Integrated Antennas of the BTS3900E
ANTA_TX/RX
45Nm
M30
M63.0
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
55/6654
Powering on the BTS3900E
Power on the BTS3900E
Start
End
Check whether the status of the RUN
LED is 0.125s ON, 0.125s OFF and that
of ALM LED is OFF?
Rectify the fault
Yes
No
When the BTS3900E is unpacked, it must bepowered on within 24 hours. Each time the
BTS3900E is maintained after being put into use,the power-off duration cannot exceed 24 hours.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
56/6655
Appendix
Lifting the CPRI optical cable up to the tower
Color tape
Corrugated pipe
1. Cut off a 200mm long corrugated pipe with thediameter of 25mm.
2. Lead the fiber tails labeled 1A and 1B of theoptical cable into the corrugated pipe by 160mm.3. Wrap the corrugated pipe and optical cable with
the color tape.4. For the tower made of steel pipes, tie the blackjacket to the corrugated pipe at the position 150 mm
away from the color tape, and then lift the opticalcable up to the tower.5. For the tower made of angle steel girders, carry
the optical cable onto the tower when climbing up to
the tower.6. After the optical cable is lifted up to the tower,
remove the color tape and corrugated pipe beforeinstalling the optical cable.
Binding Waterproof Labels
Attach waterproof labels to corresponding cables
The default position for attaching a waterprooflabel is 2cm away from the connector. In special
scenarios, the label can be attached at anotherposition to avoid a bend of a cable or a positionwhere installation is difficult. Generally speaking,
all the waterproof labels should be attached neatlyand consistently.
Both ends of a cable near connectors should beattached with waterproof labels, and the silkscreen
on the label should be in consistent with the
corresponding cable.For details, see the precedingfigure.
Silkscreen on the
Waterproof Label
Cable
PWR Power cable
SFP Signal cable forcombined
BTS3900Es
ALM Alarm cable
E1 E1 cable
FE FE cable
ANTA RF jumper
ANTB
GND PGND cable
Mapping of waterproof labels and cables
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
57/6656
Add two OT terminals to the end of the power cable
Making OT Terminals by Using a Wire Stripper (Recommended)
-48V DC power cable-48V DC power wire
GND wireShielding layer
OT terminals
Determine lengths of power cables for differentoperations according to the scales on the inner
side of the cover plate of the cabling cavity.
Based on the determined length, remove thejacket and shielding layer from the power cable.
Add an OT terminal to each wire.
Strip a 15 mm jacket off the power cable toreveal the shielding layer of the power cable.
Remove the jacket from each wire.
The assembling of OT terminals to the powercable must be complete before the BTS3900E
is installed.
Appendix
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
58/6657
1 2 3
4 5 6
7 8 9
10 11 12
Making OT terminals at the input end of the power cable by using a knife
Do not damage theshielding layer of the
power cable whencutting the jacket.
Appendix
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
59/6658
Pin Assignment for the Wires of the Alarm Cable
Appendix
Wire Type LabelWire ColorWireDB15 Connector
GNDX1.8
X1.3
Twisted pairX1.1
X1.6 GND
SWITCH_H1
X1.2
X1.7 GND
SWITCH_H2
SWITCH_H3
X1.9
X1.4
GND
SWITCH_H4
X1.11
X1.12
PSU485 TX-
PSU485 TX+
X1.13
X1.14
PSU485 RX-
PSU485 RX+
White
Blue
White
Orange
White
Green
White
Brown
Blue
Red
Orange
Red
Twisted pair
Twisted pair
Twisted pair
Twisted pair
Twisted pair
X2.1
X2.3
X2.5
X2.7
X2.6
X2.2
X2.4
X2.8
X2.9
X2.10
X2.11
X2.12
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
60/6659
Pin Assignment for E1 Cablee
Pin of the DB9 female
connector
Wire type Coaxial Series
NO.
Signal Description
X1.1 Tip 2 R0 -
X1.2 Ring -
X1.3 Tip 4 R1 -
X1.4 Ring -
X1.6 Tip 1 T0 -
X1.7 Ring Start X1.Shell
X1.8 Tip 3 T1 -
X1.9 Ring Start X1.Shell
75-ohm E1 cable
Pin of the DB9 female
connector
Color Wire type Signal Label
X1.1 White Twisted pair R0 R0+
X1.2 Orange R0-
X1.3 White Twisted pair R1 R1+
X1.4 Brown R1-
X1.6 White Twisted pair T0 T0+
X1.7 Blue T0-
X1.8 White Twisted pair T1 T1+
X1.9 Green T1-
120-ohm E1 cable
Appendix
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
61/6660
AppendixAppendix
f General Cabling Requirements1. The bending radius of the cables must meet the following specifications:
The bending radius of the 7/8'' feeder must be more than 250 mm (9.84 in.), and the bending radius of the 5/4''feeder must be more than 380 mm (14.96 in.).
The bending radius of the 1/4'' jumper must be more than 35 mm (1.38 in.). The bending radius of the super-flexible 1/2'' jumper must be more than 50 mm (1.97 in.), and the bending radius of the ordinary 1/2'' jumper mustbe more than 127 mm (5 in.).
The bending radius of the power cable or PGND cable must be at least five times the diameter of the cable.The bending radius of the optical fiber must be at least 20 times the diameter of the optical fiber.The bending radius of the E1/T1 cable must be at least five times the diameter of the cable.
The bending radius of the signal cable must be at least five times the diameter of the cable.
2. The cables must be bound as follows:
Different types of cables must be separately routed and cannot be entangled.The cables must be bound tightly and neatly. The sheaths of the cables must not be damaged.
The cable ties must face the same direction, and those at the same horizontal line must be in a straight line. Extra length of cable ties must be cut.Labels or nameplates must be attached to the cables after they are installed.
3. The cables must be routed as follows:
Different types of cables must be separately routed with a minimum space of 30 mm (1.18 in.) between everytwo cables.
Different types of cables must be installed in an untangled and orderly fashion.Different types of cables must be routed in parallel or separated by special objects.
1. Cabling requirements for power cables are as follows:
g Special Cabling Requirements-48 V DC power cables must be bound together.+24 V DC power cables must be bound together.
Power cables, transmission cables, and signal cables are routed separately.Multiple power cables must be bound when routed.Power cables must be installed in the position specified in engineering design documents.
If the length of power cables is insufficient, replace the cables rather than adding connectors or soldering jointsto lengthen the cables.
2. Cabling requirements for PGND cables are as follows:
PGND cables for the base station must be connected to the same ground bar.PGND cables must be buried in the ground or routed indoors. They should not be routed overhead before they
are led into the equipment room.The exterior of the coaxial wire and the shield layer of the shielded cable must have proper electrical contactwith the metal surface of the equipment to which they are connected.
PGND cables and signal cables must be installed in an untangled and orderly fashion. A certain distance mustbe reserved between them to prevent interference from each other.Fuses or switches must not be installed on the PGND cables.
Other devices must not be used for electrical connections of the PGND cables.All the metal parts in the housing of the equipment must be reliably connected to the ground terminal.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
62/6661
AppendixAppendix
g Special Cabling Requirements3. Cabling requirements for E1 cables are as follows:
E1 cables must not cross power cables, PGND cables, or RF cables when routed. If transmission cables arerouted with power cables, PGND cables, or RF cables in parallel, the spacing between them must be greater than
30 mm (1.18 in.).E1 cables are routed straightly and bound neatly with cable ties.Sufficient slack is provided in E1 cables at turns.
4. Cabling requirements for optical fibers are as follows:
Do not stretch, step on, or place heavy objects on optical fibers. Keep the fibers away from sharp objects.When optical fibers are routed, the extra length of the fibers must be coiled around special devices, such as a
fiber coiler.When coiling optical fibers, apply even strength. Do not bend the fibers with force.Vacant optical connectors must be covered with dustproof caps.
h Appearance of the Cables Installed in the BTS3900Eon the wallTransmission device
Alarm device
External power supply system
Cascaded SFP cables
Cascaded optical fiber
Main cabinet
Extension cabinet
When the spacing between the maincabinet and the extension cabinet is less
than 2 m, the cascaded SFP cableshould be used. If the spacing betweenthe main cabinet and the extension
cabinet is within the range from 2 m to 10m, the cascaded optical fiber should beused.
Bending radius of the cables shouldmeet the specifications.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
63/6662
Appendix
Uplink cableRF jumper
Downlink cable:Power cable
PGND cable
Alarm CableTransmission cable
Cascaded signalcable
i Appearance of the Cables Installed in the BTS3900Eon the pole
A certain distance should be reservedbetween the AC power cable and
other cables.
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
64/6663
Selecting the installation position of the grounding clip and stripping off thecable sheath with electric knife without any damage to the shielding layer.
Fixing the grounding clip and waterproofing it.
The angle resulting from the grounding wire of the clip and the cable shouldnot be larger than 15 degrees. When the cable is vertically routed, the
grounding wire of the clip should be led downwards.
Appendix
j Installing the Grounding Clip
7/21/2019 Bts3900e Gsm Installation Guide(v600r013c00_01)(PDF)-En
65/6664
Change History
This describes the changes in the BTS3900E Installation Guide .
01 (2011-09-15)
This is the first release.