Date post: | 16-Aug-2015 |
Category: |
Government & Nonprofit |
Upload: | neeraj-mandloi-ias |
View: | 315 times |
Download: | 2 times |
MODEL BUILDING BYE-LAWS, 2015
Ministry of Urban Development
The relevance of Model Building Bye-Laws with respect to URDPFI and NBC
RELEVANCE OF BUILDING BYE-LAWS
2
Aspect Model Building ByelawsUrban and Regional Plan Formulation
and Implementation (URDPFI) Guidelines
National Building Code
Purpose
Building Permission and regulating construction of buildings.
Preparing Land Use the Master Plans The Code contains administrative regulations, development control rules and general building requirements.
Agency and Use
Municipal Corporations and Urban Development Authorities.
State Town and Country Planning Depts, and Urban Development Authorities.
All Private and Public building construction agencies
Broad areas/
Coverage
Building design as per Plan Guidelines and additionally looking into- Water supply, Sanitation, Fire safety Structural safety Air-conditioning
Land use Classification, Zoning regulations/ Population density, Development promotion regulations, Growth directions and Future infrastructure needs. FAR/FSI Ground Coverage Set Backs Height
To ensure compliance in terms of Development Control Regulations and General Building requirements of building Safety and Services. Fire & Life Safety Building Materials Structural Safety Construction Safety Building Services Landscaping
STRUCTURAL SAFETY – Post Bhuj Earthquake disaster, the MBBL-2004 advised
compliance with all IS Codes for Earthquake resistance of buildings.
Achievement: 34/36 States/UT have incorporated norms
BARRIER FREE PUBLIC BUILDINGS – It was advised to make the provisions for Public and Community buildings
(excluding residential buildings).Achievement: 28/36 States/UT have incorporated norms
MANDATORY RAINWATER HARVESTING – It was advised to make provisions in all new proposed buildings on plots more than 100 sq.m. including
storage or recharge.Achievement: 30/36 States/UT have incorporated norms
MODEL BUILDING BYE-LAWS, 2004
WASTE WATER RECYCLING SYSTEMS – It was advised to make provisions in
buildings having discharge volume of more than 10000 Lt.
ROOFTOP SOLAR WATER HEATING SYSTEMS– It was advised to make provisions in all Public and Community buildings including residential buildings of plinth area more than 150sqm.
FIRE SAFETY– It was advised to make provisions for all new Public buildings as per NBC 2005 Norms.
Achievement: 36/36 States have incorporated Norms
MODEL BUILDING BYE-LAWS, 2004
Out of 36 states and UTs,
22 have undertaken
Comprehensive Revision
of their respective Building Bye-Laws
Since 2004
MODEL BUILDING BYE-LAWS, 2004
Raison d'être for revising the Bye-Laws are as under:
1. Growing Environmental concerns
2. Increased Safety and Security measures
3. Technological Developments
4. Components of Swachh Bharat Mission
5. Focus on Ease of Doing Business
Why Revise Model Building Bye-laws 2004
7
Stakeholder Consultationon Draft MBBL 2015
8
The Draft Model Building Byelaws were circulated (Jan ‘15) • Central Governments agencies/ Institutes:
National Disaster Management Authority Bureau of Indian Standards National Building Construction Corporation National Remote Sensing Centre Delhi Development Authority National Capital Region Planning Board Indian Institute of Public Administration Municipal Corporation of Delhi (South) Housing and Urban Development Corporation Schools of Planning and Architecture
•State Government Departments •Town and Country Planning Departments•Selected Urban Development Authorities •Selected Urban Local Bodies.•Associations like CREDAI and NAREDCO
Safety and Security:
Structural Safety – incorporating provisions of Disaster management as per recommendations of Prof. Arya Committee Report
BIS Codes for General, Cyclone, Earthquake and Landslide safety in buildings
Format for Structural Design Basis Report (SDBR) for various building types
Seismic strengthening/retrofitting of buildings Preventive measures against “Soft Storeys” in multistoreyed buildings Proof Checking of Structural Design for Buildings
Salient Features of MBBL (2015) -I
10
Barrier Free Environment
Building & Site for Differently abled, Elderly and Children. Design provisions for Disabled People including Non-Ambulant People (using small wheel chairs) Site development , Access Path / Walk Way , Parking, Building requirements Stair, Lifts, Toilets, Designing for Children, Drinking Water, Refuge and signage
Salient Features of MBBL (2015) -II
Salient Features of MBBL (2015) -III
Environmental Concerns
Green Buildings
Rainwater Harvesting
Solar Roof Top
Waste water Reuse and Recycle
12
Adaption for Modern Construction Technology:
Provisions for High-rise Building regulations Parking provisions (Podium and others). Peripheral Open Spaces including set-backs Disaster Management And Fire Safety Environment Protection and Preservation Plan Exclusions and exceptions and Structural Safety Definitions for High Rise, Plot Area, Means of access Building components, Building Services, Helipad
Salient Features of MBBL (2015) -IV
13
Technology Tools for Governance:
Online submission of Building proposal, scrutiny and approval systems. Adopt automated systems of plan scrutiny and generation
of reports Timely and integrated systems of intimation to applicant
of approval status Generation of Compliance report from drawings for
Completion certificate
Salient Features of MBBL (2015) -V
14
Following Swachh Bharat Mission:
Revised Norms for adequate toilet facilities for women.• Revised provision of ratio of toilets for women based on higher work
participation
Provisions of Public Conveniences in Public BuildingsMandatory Provisions for Segregated toilet facilities for visitors in Public Buildings
Salient Features of MBBL (2015) -VI
15
Ease of Doing Business:
Online Building plan approval process
Integration of various clearances at Master Plan levels
Integrating “Single Window” process
Empowering Architects
Outsourcing non discretionary verification jobs
Citizen’s Charter
Salient Features of MBBL (2015) -VII
16
Material Technology and Communication Technology:
Bye-Laws for safe use of Glass in Buildings. Identifying different Types of Safety Glasses
to be used as building components Precautions/ measures and Installation Critical location of glasses within the building and for furniture. Standards for Proper Selection Codes, Standards and Publications
Salient Features of MBBL (2015) -VIII
Chapter on Rain Water Harvesting
Importance
Indicative Provisions for Various types of Buildings
Responsibility of ULBs for public spaces
Enforcement and Monitoring
Technological Options
Salient Features of MBBL (2015) -IX
18
Effects of Communication Technology:
Draft Guidelines for mitigation of
Electro Magnetic Radiations in built spaces. Identifying different Types of Electro
Magnetic radiations and emitting
appliances/sources Effects of prolonged Exposure Guidelines for Buildings and Built Forms Indoor and Outdoor Appliances and
Equipment. Standards for Proper Placement
Salient Features of MBBL (2015) -X
19
LINKAGE TO AMRUT REFORMS
Likely to Be approved by the ministry by August 2015
THANK YOU