BURNDYWedge
BURNDY WEJTAP™SELECTION CHART
By Diameter
CatalogNumber
Sum Of Diameters
Max Win
Run
Max Min
Tap
Max Min
Installed with blue boosters
WCB10
WCB11
WCB12
WCB13
WCB14
WCB15
WCB16
WCB17
WCB18
WCB19
WCB20
WCB21
WCB22
WCB23
WCB24
WCB25
WCB26
WCB27
WCB28
WCB40
WCB41
WCB42
WCB43
WCB44
WCB45
WCB46
WCB47
0.795
0.901
0.707
0.761
0.839
0.769
0.823
0.963
1.011
1.068
1.13
0.846
0.9
0.972
1.052
1.104
1.163
1.221
1.284
0.888
0.942
1.011
1.094
1.146
1.204
1.284
1.368
0.621
0.763
0.526
0.6
0.69
0.622
0.664
0.804
0.867
0.938
0.975
0.711
0.765
0.818
0.897
0.963
1.015
1.08
1.141
0.762
0.794
0.857
0.936
1.009
1.057
1.119
1.188
0.482
0.568
0.568
0.568
0.568
0.568
0.568
0.568
0.568
0.568
0.568
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.684
0.684
0.684
0.684
0.684
0.684
0.684
0.684
0.316
0.364
0.364
0.364
0.364
0.364
0.364
0.364
0.364
0.364
0.364
0.532
0.532
0.532
0.532
0.532
0.532
0.532
0.532
0.603
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.437
0.457
0.204
0.258
0.398
0.204
0.258
0.464
0.572
0.572
0.572
0.204
0.258
0.33
0.5
0.562
0.562
0.575
0.65
0.204
0.258
0.333
0.5
0.562
0.562
0.592
0.684
0.257
0.257
0.162
0.204
0.257
0.162
0.204
0.257
0.364
0.379
0.386
0.162
0.204
0.257
0.324
0.364
0.409
0.46
0.525
0.162
0.204
0.257
0.324
0.364
0.409
0.46
0.6
Installed with red booster
WCR1
WCR2
WCR29
WCR3
WCR30
WCR31
WCR32
WCR33
WCR34
WCR35
WCR36
WCR37
0.723
0.602
0.723
0.656
0.656
0.602
0.53
0.459
0.324
0.56
0.487
0.416
0.584
0.464
0.584
0.516
0.516
0.464
0.41
0.331
0.256
0.452
0.387
0.297
0.398
0.398
0.398
0.398
0.398
0.398
0.326
0.258
0.162
0.398
0.398
0.258
0.257
0.258
0.257
0.258
0.257
0.257
0.204
0.169
0.128
0.257
0.257
0.169
0.398
0.258
0.398
0.325
0.325
0.258
0.258
0.23
0.162
0.162
0.162
0.162
0.257
0.162
0.257
0.206
0.206
0.162
0.162
0.162
0.128
0.128
0.128
0.128
Installed with yellow booster
WCY100
WCY101
WCY102
WCY1 03
1.572
1.503
1.454
2.604
1.4
1.343
1.284
2.484
1.25
1.25
1.25
1.302
0.893
0.893
0.893
1.242
0.351
0.261
0.198
1.302
0.257
0.204
0.162
1.242
BURNDYWedge
INTRODUCTIONThe BURNDY WEJTAP System componentsare designed to provide the most reliable con-nections available, with safer and easierinstallations.
The system consists of a WEJTAP connector,WEJTAP installation tools and power-boosters.
The detailed information on power-boosters,installation tools and accessories follows.
The BURNDY WEJTAP connector uses analuminum alloy wedge that is power-drivenbetween the run and tap cables locking theminto a "C" shaped aluminum alloy spring-body.
A wiping action takes place during installationbetween the conductors and Wedge whichprovides additional cleaning of surface oxidesto supplement wire brushing. In addition, thecontact grooves are lined with a patentedPENETROX™ oxide inhibiting compound toenhance superior contact surface integrity.
The Wedge is automatically locked onto thespring-body by a skiving action produced by alance located at the forward end of the instal-lation tool.
During the life of the connection, the spring-body continues to maintain pressure toensure a reliable connection.
THE WEJTAP™CONNECTOR• Tested to NEMA and CSA Class A heat
cycle requirements to ensure long termreliability.
• Accommodates a full range of run and tapconductors from #8 to 1590 ACSR in allcommonly used conductors to meet theneeds of electrical distribution systems.
• Color-coded connector, boosters, andtools to assist the installer to make thecorrect selection.
• "Run locator" chamfer is machined intothe Wedge at the end of the "large" grooveto provide positive visual or/and hand con-tact identification of the large run groovefor correct installation.
• Removable design allows tap removalwith minimum conductor damage.
• Tool embosses BURNDY identifier on endof Wedge to provide system identification.
Ask about our unique WEJTAP Tool Systemand Power-Booster which provides safer andeasier installations.
IBURNDYWedge
WEJTAP™ ANDTEST DATAWEJTAP™ connectors have been subjectedto extensive tests simulating the most severeservice and weather conditions. In addition,the WEJTAP™ system meets or exceeds theindustry standards of ANSI C119.4 Class 3,NEMA CC3 1973 Class A 500 Heat Cycles.
As with all BURNDY connectors, the WEJ-TAP™ has been designed to operate coolerthan the attached conductors. The WEJ-TAP™ connectors have also been subjectedto the ASTM B117-73 Salt Spray Test. Theresults are shown to the right.
ANSI C119.4 -1986 Heat Cycle TestAverage Temperature Rise vs. Current Cycles
Q
2ir
ASTM Salt Spray TestAverage % Relative Resistance vs. Hours of Salt Spray Exposure
L_L_J__l__j *
I | T~~ "! TesrConn
Conlrot Co
•— *?"*•*|
— — i_--—
ector
nduciof
i Limit| K-rx
Detailed test report packages are available upon request.
WEJTAP™
Spring-bodies are color-coded and thewedges are marked with nominal conductorrun and tap ranges. WEJTAP™ connectorpackages are labeled with a variety of com-mon conductors with their nominal ranges.
• WEJTAP™ connector wedges are markedwith nominal ACSR. Aluminum and Copperconcentric standard conductors.
• Red WEJTAP™ connector range Run 8-1/0Tap 8-2
• Blue WEJTAP™ connector range Run2-300 Tap 6-300
• Yellow WEJTAP™ connector range Run266.8-1590 Tap 6-1590
All WEJTAP™ wedges contain a clearlydefined chamfer on the large end of the runconductor groove to identify the "large run"groove. Installers will appreciate the conve-nience of visual or hand identification forcorrect wedge positioning.
WEJTAP™ wedges are driven between therun and tap conductors and activate thespring characteristics of the "C" shaped body.This action maintains contact pressure evenwhen the connection is subjected to severeclimatic and electrical conditions.
IBURNDYWedge
BURNDY WEJTAP™CONNECTORSELECTOR CHART
By Conductor Size
RUN
(O
iDCCO0<
34
iiDCco0<
______37
33
54-ccCO0<
37
33
32
?CM
CCCOO<
36
32
31
10
CO
O
DCCOO<
35
12
13
10
10
(O
1CCCOO<
12
13
10
11
11
CO
O
?CCCOO<
12
13
11
11
17
18
ACSR TO ACSR
ICCCOO<c
15
16
11
17
18
19
20
T—
CO
COCDtOOJ
CCCOO<
21
22
23
24
25
26
27
28
23
4CDncoCCCO0<
40
41
42
43
44
45
46
47
47
§
int^<T>CO
DCCO0<
59
58
57
66
65
64
64
63
62
62
co
qlN«tDCCOO<
59
58
57
66
65
64
64
63
62
61
61
|
inCDininDCCOO<
70
69
67
65
64
63
63
62
61
61
61
60
iCO
O
ineniv.CCCOO<
85
84
83
81
81
79
79
78
77
76
75
74
72
CDcp0
*±in0)
DCCOO<
02
01
00
99
98
97
96
96
95
94
93
92
89
87
iCO
incoCO0
CCCOO<
02
01
00
98
97
96
95
95
94
93
92
91
88
87
86
ACSR#8-6/1
ACSR#6-6/1
ACSR#4-6/1
ACSR#2-6/1
ACSR-1/0-6/1
ACSR-2/0-6/1
ACSR-3/0-6/1
ACSR-4/0-6/1
ACSR-266.8-18/1
ACSR-336.4-18/1
ACSR-397.5-18/1
ACSR-477.0-18/1
ACSR-556.5-18/1
ACSR-795.0-36/1
ACSR-954.0-36/1
ACSR-1 033.5-36/1
COLORBLUEBLUERED
YELLOWYELLOW
NUMBER10-2840-4729-3748-9900-39
CODEB
BR
Y
Y
CONNECTORWCB20WCB40WCR30WCY99WCY100
(100-139) IF YELLOW, INSERT 1 BEFORE 00-39
•When ordering, add WC and color codebefore number
• Further information may be obtained bycontacting BURNDY at 1-800-346-4175
BURNDYWedge
BURNDY WEJTAP™CONNECTORSELECTOR CHART
By Conductor Size
RUN
AC
SR
# 8
-6/1
34
AC
SR
# 6
-6/1
37
•
AC
SR
# 4
-6/1
33
32
AC
AC
SR
# 2
-6/1
•32
31
30
SRI
i0
DC(/)0<
12
13
10
10
•QA
i§oc(/)0<
12
13
10
11
11
AC
i
DC</)o<
12
13
11
11
17
18
AC
SR
-4/0
-6/1
15
16
11
17
18
19
20
CO
00CDCO04
DC(/}O<
21
22
23
24
25
26
27
28
co^4CDCOCO
cc(/}o<
40
41
42
43
44
45
46
46
47
iinis!CDeoCCCOO<
59
58
57
67
66
65
64
63
62
62
00
ois!h-"3-ccCOo<
59
58
57
67
66
65
64
63
62
62
61
CO
incdininCC(/)O<
70
69
68
66
65
64
63
62
62
61
61
60
coCO6ino>N.cc(/)O<
85
84
83
82
81
80
79
78
77
77
76
75
72
5CO6*rmencc(/>o<
02
01
00
00
98
98
97
96
95
94
93
92
89
88
CDCOinCOCOoT™
CC(/}0<
02
01
00
99
98
97
96
95
94
93
92
92
88
87
86
AAC#8
AAC#6
AAC #4
AAC#2
AAC-1/0
AAC-2/0
AAC-3/0
AAC-4/0
AAC-266.8
AAC-336.4
AAC-397.5
AAC-477.0
AAC-556.5
AAC-795.0
AAC-954.0
AAC-1 033.5
Q.<
COLORBLUEBLUERED
YELLOWYELLOW
NUMBER10-2840-4729-3748-9900-39
CODEB
B
R
Y
Y
CONNECTORWCB20WCB40WCR30WCY99
WCY100
(100-139) IF YELLOW, INSERT 1 BEFORE 00-39
•When ordering, add WC and color codebefore number
•Further information may be obtained bycontacting BURNDY at 1-800-346-4175
!BURNDYWedge
BURNDY WEJTAP™CONNECTORSELECTOR CHART
By Conductor Size
RUN
?CO
*CCCOo<
34
5CO
*CCCOo<
37
33
/
T~
#DCCO337
33
32
VCSF
AC
SR
# 2-
6/1
36
32
31
30
*TO
CO
0
CCCOo<
35
12
13
10
10
COF
CD
1enCOo<
12
13
10
11
11
>PEF
CDiVCCCOo<
12
13
11
11
17
18
*
CD
ICCCOo<
15
16
11
17
18
19
20
5
00COCD<N
CCCOo<
21
22
23
24
25
26
27
27
I
<a-CDcocoCCCOO<
40
41
42
43
44
45
46
46
47
oo
iniencoCCCOo<:
59
58
57
67
66
65
64
63
62
62
|
or--'h-•efr
CCCOo<
59
58
57
67
66
65
64
62
62
61
76
|
inCDininCCCO0<
70
69
68
66
65
64
63
62
61
61
75
92
35CO
pin0>r»CCCO0<
85
84
83
82
81
80
79
78
77
75
72
89
CDcoq"3-incpCCCO0<
02
01
00
00
98
98
97
96
95
93
90
87
jrcoCO
COco0
CCCO0<
02
01
00
99
98
97
96
95
94
92
89
87
COPPER #8
COPPER #6
COPPER #4
COPPER #2
COPPER-1/0
COPPER-2/0
COPPER-3/0
COPPER-4/0
COPPER-250.0
COPPER-350.0
COPPER-500.0
COPPER-750.0
COPPER-1000.0
COLORBLUEBLUERED
YELLOWYELLOW
NUMBER10-2840-4729-3748-9900-39
CODEB
BR
Y
Y
CONNECTORWCB20WCB40WCR30WCY99
WCY100
(100-139) IF YELLOW, INSERT 1 BEFORE 00-39
•When ordering, add WC and color codebefore number
•Further information may be obtained bycontacting BURNDY at 1-800-346-4175
BURNDYWedge
BURNDY WEJTAP™CONNECTORSELECTOR CHART
By Conductor Size
RUN
co
6<<
If
86<<
37
33
T*6<<
37
33
32
A;
CM
6<<
36
32
31
30
V C T
0
6<<
35
12
13
29
10
o A;
?o<<
12
13
10
14
11
vc
16<<
12
13
14
11
17
18
AA
C-4
/0
15
16
11
17
18
19
20
CO<D(DCNI
6<<
21
22
23
24
25
26
27
28
<a;CDCOCO
6<<
40
41
42
43
44
45
46
46
47
int^o>CO
6<<
48
49
50
51
52
53
54
55
56
56
o
£*6<<
59
58
57
67
66
65
64
63
62
62
62
inCDinin6<<
59
58
57
66
65
64
63
62
62
61
61
60
oinO)h-6<<
85
84
83
82
81
80
79
78
77
77
76
75
72
o
sO)CJ<<
02
01
00
99
98
98
97
96
95
94
93
92
89
88
inCOCO0
6<<
02
01
00
00
98
97
96
95
94
93
92
92
88
87
86
AAC#8
AAC#6
AAC#4
AAC#2
AAC-1/0
AAC-2/0
AAC-3/0
AAC-4/0
AAC-266.8
AAC-336.4
AAC-397.5
AAC-477.0
AAC-556.5
AAC-795.0
AAC-954.0
AAC-1 033.5
COLORBLUEBLUERED
YELLOWYELLOW
NUMBER10-2840-4729-3748-9900-39
CODEB
B
R
Y
Y
CONNECTORWCB20WCB40WCR30WCY99WCY100
(100-139) IF YELLOW, INSERT 1 BEFORE 00-39
•When ordering, add WC and color codebefore number
• Further information may be obtained bycontacting BURNDY at 1-800-346-4175
i
BURNDYWedge
BURNDY WEJTAP™CONNECTORSELECTOR CHART
By Conductor Size
RUN
AA
C-#
8
34L
AA
C-#
6
37
33
<**6<<
1 • — : —37
33
32
*6<<
36
32
31
30:
o
6<<
35
12
13
29_^_
10
o?36<<
12
13
10
14
11
oco6<<
12
13
14
11
17
18
AAC TO COPPER
0
6<<
15
16
11
17
18
19
20
ooid10CNJ
6<<
21
22
23
24
25
26
27
27
n-<dCOcp6<<
40
41
42
43
44
45
46
46
47
U)iv0>cp6<<
48
49
50
51
52
53
54
55
56
62
0Nf«-«a-6<<
59
58
57
67
66
65
64
63
62
61
76
it)CDLO
•4o<<
59
58
57
66
65
64
63
62
61
61
75
92
qLT50)t^-6<<
85
84
83
82
81
80
79
78
77
75
72
89
0
s0>O<<
02
01
00
99
98
98
97
96
95
93
90
88
if>COCO0!•»
6<<
02
01
00
00
98
97
96
95
94
92
89
87
COPPER #8
COPPER #6
COPPER #4
COPPER #2
COPPER-1/0
COPPER-2/0
COPPER-3/0
COPPER-4/0
COPPER-250.0
COPPER-350.0
COPPER-500.0
COPPER-750.0
COPPER-1000.0
COLORBLUEBLUEREDYELLOWYELLOW
NUMBER10-2840-4729-3748-9900-39
CODEB
BR
Y
Y
CONNECTORWCB20WCB40WCR30WCY99WCY100
(100-139) IF YELLOW, INSERT 1 BEFORE 00-39
•When ordering, add WC and color codebefore number
• Further information may be obtained bycontacting BURNDY at 1-800-346-4175