BERRIDGE MANUFACTURING COMPANY6515 Fratt Rd, San Antonio, TX 78218800-669-0009 | 210-650-3050 | Fax 210-650-0379
• High-Strength Coated Steel• Residential & Commercial Buildings• Use With Metal Roofing or Siding or Any Standard Building Material
CONTRACTOR TRAINING AVAILABLE
05 40 00/BERBuyLine 8668
Reasons to Use Steel Framing Instead of Wood Framing:
· Fire & Termite Proof • Will Not Mold or Rot • Permanent Structural integrity • Superior Structural Performance & Longevity • Moisture Proof • Warp Proof • High Strength • Light Weight • Will Not Lose
Strength • Low Cost • Long Lasting Coated Steel • Dimensionally True • Steel is Recyclable • Environmentally Friendly
NEW GREEN BUILDING PRODUCT!NEW GREEN BUILDING PRODUCT!
BERRIDGE SPACEFRAMEBUILDING SYSTEM COMPONENTS
BERRIDGE SPACEFRAMEBUILDING SYSTEM COMPONENTS
Patent Pending
GROSS PROPERTIES
THICKNESS(in)
0.024
DEPTH(in)
3.5
FLANGE(in)
1.450
LIP(in)
---
Ag(in2)
0.157
Ix(in4)
0.252
Sx(in3)
0.155
Iy(in4)
0.043
Sy(in3)
0.039
rx(in)
1.265
ry(in)
0.526
TORSIONAL PROPERTIES
J(in4)
0.00003023
Cw(in6)
0.0715
Xo(in)
-1.045
Ae(in2)
0.105
Ix(in4)
0.252
Sx(in3)
0.155
TENSION(lbs)
3771
MOMENT(lbs-ft)
309
SHEAR(lbs)
1171
PHYSICAL PROPERTIES GROSS PROPERTIES
THICKNESS(in)
0.024
DEPTH(in)
3.5
FLANGE(in)
1.450
LIP(in)
---
Ag(in2)
0.31491
Ix(in4)
0.504
Sx(in3)
0.309
Iy(in4)
0.149
Sy(in3)
0.097
rx(in)
1.265
ry(in)
0.689
TORSIONAL PROPERTIES FULL BRACED PROPERTIES & ALLOWABLE STRENGTH
J(in4)
0.00006046
Cw(in6)
0.14307
Xo(in)
0.00
Ae(in2)
0.21001
Ix(in4)
0.504
Sx(in3)
0.309
TENSION(lbs)
7542
MOMENT(lbs-ft)
618
SHEAR(lbs)
2343
SINGLE 24 GA STUD
DOUBLE 24 GA. STUD
Berridge Spaceframe Building System Components
PHYSICAL PROPERTIES
FULL BRACED PROPERTIES & ALLOWABLE STRENGTH
BERRIDGE SPACEFRAME: A GREEN, SUSTAINABLE WAY TO BUILD
Uses and Applications:Berridge Spaceframe Building System Com-ponents are used in single and multi-family residential, light commercial, assisted living, hotels/motels and other low-rise projects.Products in Place:Berridge Spaceframe Building System Com-ponents are used to fabricate light weight wall and roof panel assemblies that are easily transported and erected at the job site. Stan-dard components are offered to the contractor much the same as conventional timber but at about one-fourth the weight, and with absolute dimensional stability.Assembly and Installation:Berridge Spaceframe Building System Com-ponents may be quickly assembled at the construction site, with no sawing or cutting. The framing contractor is provided with simple, easily followed typical installation details.Materials and Finishes:Wall and roof panel assemblies use cold-formed, light gauge aluminum-zinc alloy coated steel, produced to highest industry standards. Stan-dard gauge thickness is .0239 24 minimum gauge 40,000 p.s.i. Grade C material to deliver maximum performance at minimum weight.Technical SupportWall and roof panel assemblies are specified using the design criteria shown in this brochure and in the “Design Manual”.
Codes and Certifications:Design professionals may use the loads and properties for Berridge Spaceframe Building Systems components to design structures which meet local building codes and other certifications.Environmental Data:Berridge Spaceframe Roof and Wall assemblies are constructed with recycled steel products from leading steel suppliers and are completely recyclable -- a “green” and “sustainable” build-ing product.
DOUBLE 24 GA STUD PROPERTIES
SINGLE 24 GA STUD PROPERTIES
Patent Pending
© Berridge Manufacturing Company 2009 - Specifications subject to change without notice www.berridgespaceframe.com
T Y P I C A L I N S T A L L A T I O N D E T A I L S
EAVE 24 GA. EDGE TRIM CONNECTION TO 16 GA. CEE-CHANNEL
BACK-TO-BACK 24 GA. ROOF STUDS WITH BLOCKING AT END OF EAVE
ALTERNATE EAVE CONNECTION TO 16 GA. CEE CHANNEL ROOF STUD CONNECTION TO KNEE WALL WITH 24 GA. TRIM
24 GA. RIDGE TRIM CONNECTION BETWEEN ROOF STUDS & VERTICAL SUPPORT STUD WALL
24 GA. BLOCKING BETWEEN STUDS
24 GA. WALL STUDS CONNECTED INTO 24 GA. TRACK
05 40 00/BERBuyLine 8668
© Berridge Manufacturing Company 2009 - Specifications subject to change without noticewww.berridgespaceframe.com
BERRIDGE MANUFACTURING COMPANY6515 Fratt Rd, San Antonio, TX 78218800-669-0009 | 210-650-3050 | Fax 210-650-0379
SPACEFRAME BUILDING SYSTEM COMPONENTS
CONTRACTOR TRAINING AVAILABLE
TYPICAL FRAMING
STUD & TRACK
CONDUIT THRU STUD CEILING CHANNEL BEAMS
CORRUGATED WALL SHEATHING
STUD & BLOCKING
VALLEY FRAMING
Send for your free Design Guide:
Engineering Properties & Typical Installation Detail Drawings
Patent Pending
© Berridge Manufacturing Company 2009 - Specifications subject to change without noticewww.berridgespaceframe.com Printed in USA 2009