One-day Conference 18 March 2017 Power Supply, EMC and Signalling, in Railway Systems EMC Management and Related Technical Aspects in Railway Systems By Dr Peter S W LEUNG http://www.ee.cityu.edu.hk/~pswleung/ 1 Hong Kong Chapter
Transcript
Page 1: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

One-day Conference 18 March 2017

Power Supply, EMC and Signalling, in Railway Systems

EMC Management and Related Technical Aspects in Railway Systems

By

Dr Peter S W LEUNG

http://www.ee.cityu.edu.hk/~pswleung/

1

Hong Kong Chapter

Page 2: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

2

Fixed installation - A particular combination of several types of apparatus, and where applicable, other devices, which are assembled, installed and intended to be used permanently at a predefined location. EMC Directive 2014/30/EU ). Fixed installation/Large systems - Large in size, and require system integration.

Features :

Whole system cannot be EMC tested prior to installation Required to Commit to comply with some EMC particular specifications, code or practice.

Page 3: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

3

What is the EMC assurance process for Large Systems? EMC is an essential part in the system assurance for a complex project, in providing a top level guidelines for all parties including the contractors, subcontractors and equipment suppliers delivering the railway system to produce a structured evidence of EMC analyses and submissions. How to meet the requirements for EMC assurance?

Page 4: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

The railway environment is considered harsh with respect to Electromagnetic Interference (EMI)

function satisfactorily and safely

DDefinition of EMC : Function satisfactorily in its electromagnetic environment without introducing intolerable electromagnetic disturbances to other equipment in that environment - EMC Directive 2014/30/EU Often this is also the ultimate goal and objective of EMC management plan or control plan to the assurance process.

4

Page 5: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

The EMC Management is commonly based on a systematic approach, taking into account all sources and susceptible equipment, subsystem and systems located internally and externally to the rail environment and where all EMC interactions exists for at different levels :

Equipment level – EMC type tests… Inter-(sub)system level – EMC guidelines, Risk analysis… Extra-system level – third parties, EMC impacts, human safety issues…

5

Page 6: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

EMC Assurance Process relies on major components of:

Compliance to EMC standards and guidelines

Risk Identification and Risk Analysis

for various system integration aspects and for different prospective of an EMC solution…

EMC Risk Log or safety Hazard Log

6

Page 7: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

7

Axle counter

IInter- subsystem

Other, future

Railways

External EM Environment

Third Party Systems and Infrastructure

Extra

Extra

Extra

CBTC

Intra

SIG

Tetra

Walkie talkie

Intra

COMM

Intra

ATC

Intra

VEH

Inter- subsystem

Inter- subsystem

Inter- subsystem Rectifier

Switchgear

Inverter

Capacitor

Railway System

Extra

Airport

Extra

Police & Fire Stations

Extra

TVS

PDS

Page 8: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

8

Emissionn EEmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmiiiiiiiiiisssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssi

RE

CE

ESD

CS

RS

Page 9: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

9

Page 10: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

10

EN 55011 Industrial, scientific and medical (ISM) equipment….. EN 55022 ITE. ..Radio disturbance characteristics. Limits and methods of measurement EN 61000-4-2 ESD immunity test EN 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test EN 61000-4-4 Electrical fast transient/ Burst immunity test EN 61000-4-5 Surge immunity test EN 61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields EN 61000-4-8 Power frequency magnetic field immunity test EN 61000-4-11Voltage dips, short interruptions and voltage variations immunity tests EN 61000-4-13 Harmonics and inter-harmonics EEN61000-3-2 : Harmonics Emissions EN61000-3-3 : Flickers and voltage fluctuations

Page 11: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

• Conducted disturbance (150 kHz – 30 MHz) Class A and Class B ITE with both AAverage and Quasi peak limits Mains terminal disturbance – Voltage (in dBuV) Common mode disturbance at telecommunication ports –Voltage and Current • Radiated disturbance (30 MHz – 1 GHz) Class A and Class B ITE with Quasi peak limit Enclosure (10m distance) – E-field When reading shows fluctuations close to the limits, observed for at least 15s at each measurement frequency • Remarks: If average limit is met when using a quasi-peak detector receiver, the EUT shall deemed to meet both limits.

• Radiated disturbance (1 GHz – 6 GHz) Class A and Class B ITE with Peak and Average limits Enclosure (3m distance) – E-field When reading shows fluctuations close to the limits, observed for at least 15s at each measurement frequency.

Page 12: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

• 150KHz to 30MHz depend on type of device (steps limits at 0.15, 0.5 and 5 MHz)

• Measurement according to class A/B devices, warning shall be labelled as in Class A

Page 13: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

80MHz – 1GHz ◦ EN 61000-6-1 (RCL environment)

80M-1000MHz, 3V/m 1.4G-2GHz, 3V/m 2G-2.7GHz, 1V/m

◦ EN 50121-3-2 ( Rolling stock -Apparatus) 80M-1000MHz, 20V/m 1.4G-2GHz, 10V/m 2.1G-2.5GHz, 5V/m

To all 4 sides..

Page 14: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

14

Ambient temperature: 15 oC to 35 oC Relative humidity: 30 % to 60 % Atmospheric pressure: 86 kPa to 106 kPa

EElectrostatic Discharge (ESD) EN61000-4-2

Page 15: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

15

Discharge Electrodes of the ESD Generator

Well defined dimensions for the discharge electrodes

Threshold of feeling: 2 - 4kV Everyone can feel: 5kV Memorable event: 15kV

C = 50 to 250 pFR = 500 to 10k |VC| = 0 to 30kV ( above 30V will have corona effect ) L = 50 - 200nH First order model, TRIBOELECTRIC EFFECT

Page 16: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

simulating the impact of spark or arcing, commonly from opening/ breaking of a current flowing switch

Coupling of the EFT into electronic products occurs when power cables handling high currents are spontaneously varies nearby of power, data, I/O cables.

Page 17: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

EFT is the immunity requirement on impact from power switches

Measurement done on +/- 2KV on line-line or +/- 1KV on Line to earth

No degradation of performance (A) is expected to EUT under the influence

Page 18: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

Surges on the AC power mains is result of switching operations in power grid and from nearby lightning strikes, either directly to power distribution system or nearby ground. Radiated coupling of surges into I/O lines generally occurs when the lines are considerably lengthy (thus proud of induction). • Electronic products are tested for Surge immunity to ensure their continued reliable operation under realistic levels of surge voltages.

• It is essential to demonstrate apparatus used in Railway able to sustain and self recoverable (B) under surge conditions

Page 19: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

To simulate the impact lightening strike +/- 2KV line-line, +/- 1KV Line-Earth Functions of Railway EUT expected to be self recoverable (B).

Page 20: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

Disturbance is generated by intentional RF transmitters Cable attached to the EUT are in resonant mode (λ/4, λ/2) CDN to ensure one-directional RF injection into EUT Rail apparatus to 10V/m across 9KHz to 80 MHz

b d b l

Page 21: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time,

repeated pulse Slower rise time and declining pulse

Relative energy mJ mJ J Peak voltage 15KV 2KV 2KV Eff. Current range A A KA Sources Static Switching of circuit lighting

Page 22: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

• harmonics is regulated and verified up to 40th harmonics (2KHz).

Page 23: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

• voltage fluctuations - Certain products intermittently take power from mains and causing the supply voltage to dip, resulting potentially supplier instable, lighting to flick.

• Flicker measures current variation over time (up to 2 hours) and uses statistical techniques to quantify the severity of flicker.

Max allowable voltage fluctuation > 4% or 3.3% for disturbance >0.5s

Page 24: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

magnetic fields at AC mains frequencies, in association with power transformers. Common problems to electronic displays, Hall effect sensors, and other electronic products having a sensitivity to magnetic fields.

• EUT to sustain H field @100 A/m immunity for 50 Hz and 300 A/m for DC (no degradation (A) is allowed)

Page 25: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

In compliment with Power magnet field, Pulse Magnetic Fields are produced as a result of a large current impulse through a conductor.

Example is lightening current flowing through a grounding conductor at a power sub-station.

• Pulse magnetic fields can also occur in railway system where very large current impulses are used in a power transmission process (Traction substation).

• Immunity to pulse magnetic field of 300 A/m (self recoverable (B) is expected)

Page 26: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

Category A - The measured object continues operating normally, unaffected by the interference Category B - The measured object is interfered with, but functions without degradation once the interference has been removed Category C - Loss of function during the test, but functions resume after resetting the measured object

Category D - the function was lost permanently

Page 27: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

Compliance Matrix: Summarizing EMC type test information according to the requirements.

Pre-compliance test/ type test information.

Provide judgment on discrepancies, and justification on deviation.

Compliance Matrix:

27

Page 28: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

PDS

Signalling and Telecomm

SIG & COMM Apparatus

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSiiiiiiiiiiiiiiiiiiiiiggggggggggggggggggggggggggggggggggggggggggggggggggggggggnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaallllllllllllllllllllllllllllllllllllllllllllllllllllllliiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiinnnnnnnnnnnnnnnnnnnnnnnnnnnnng aaaaaaaand TTTTTTTTelecommmmmmmm

Page 29: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

29

EEN50121 :2015 EN50121-1 Railway Applications – Electromagnetic compatibility , Part 1 General EN50121-2 Railway Applications – EMC, Part 2 Emissions of the whole railway system to the outside world EN50121-3-1 Railway Applications – Electromagnetic compatibility , Part 3-1: Rolling Stocks EN50121-3-2 Railway Applications – Electromagnetic compatibility , Part 3-2: Rolling Stocks EN50121-4 Railway Applications – EMC, Part 4 Emission and immunity of the signalling and telecommunication Apparatus EN 50121-5 Railway applications –EMC, Part 5 Emission and immunity of fixed power supply installations and apparatus

EN61000-6 EN 61000-6-1 EMC. Generic standards - Immunity for residential, commercial and light-industrial environments EN 61000-6-2 EMC Generic Standard – Immunity for industrial environments EN 61000-6-3 EMC - Generic standards. Emission standard for residential, commercial and light-industrial environments EN 61000-6-4 EMC - Generic Standard – Emission standard for industrial environments Others EN 61000-5-2 Electromagnetic Compatibility (EMC): Part 5 Installation and mitigation guidelines, Section 2 Earthing and cabling EN 62128-1 Railway applications – Protective Provisions against Electric Shock EN 62305 Protection against lightning(Parts 1-4)

Page 30: By Dr Peter S W LEUNG · `Rail apparatus to 10V/m across 9KHz to 80 MHz bdbl. ESD EFT Surge Pulse characteristic Sharp rise time Sharp rise time, repeated pulse Slower rise time and

30

System Level - EN50121 :2015 EN50121-1 Railway Applications – Electromagnetic compatibility , Part 1 General EN50121-2 Railway Applications – EMC, Part 2 Emissions of the whole railway system to the outside world EN50121-3-1 Railway Applications – Electromagnetic compatibility , Part 3-1: Rolling Stocks EN50121-3-2 Railway Applications – Electromagnetic compatibility , Part 3-2: Rolling Stocks EN50121-4 Railway Applications – EMC, Part 4 Emission and immunity of the signalling and telecommunication Apparatus EN 50121-5 Railway applications –EMC, Part 5 Emission and immunity of fixed power supply installations and apparatus