Fire Alarm Systems | BZ 500 LSN Fire Panel The BZ 500 LSN is the ideal fire panel for small and medium- sized objects and offers all the benefits of modern bus technology. Modular extension options make it possible to easily adapt the fire panel to changed operating conditions. Flexible detector integration makes extending the fire alarm system simple and cost-effective. System Overview BE 500 BAT 100 LSN (230 V) Fire 1 2 3 7 8 0 9 5 6 4 BZ 500 LSN 0 400 LSN 0T 400 LSN 0C 410 LSN 0TC 410 LSN T 400 LSN MSS 400 SA MSS 400 DM 210 LSN Feuerwehr SM 210 LSN Feuerwehr 0T 300 GLT FK 100 LSN NBK 100 LSN DOW 1171 Fire 1 2 3 7 8 0 9 5 6 4 SM 20 SM 20 1 2 3 Pos. Description 1 Conventional technology 2 LSN loop 3 Radio technology BZ 500 LSN Fire Panel Easy installation due to modular configuration Up to two loop or four stub lines can be connected For max. 254 LSN elements in up to 64 detector zones and 16 control groups Separate alarm counter for fire alarms and test alarms Self-monitoring of processor technology (Watchdog) www.boschsecurity.com
Transcript

Fire Alarm Systems | BZ 500 LSN Fire Panel

The BZ 500 LSN is the ideal fire panel for small and medium-sized objects and offers all the benefits of modern bustechnology.

Modular extension options make it possible to easily adaptthe fire panel to changed operating conditions. Flexibledetector integration makes extending the fire alarm systemsimple and cost-effective.

System Overview

BE 500

BAT 100 LSN

(230 V)

Fire Alarm

Next TypeMessage

FireExternal Alarm

NextMessage

1 2 3

7 8

CE

no yesStop

Enter

Day/NightOn/Off

ResetSystem

Code

Malfunction

System

Transmission unit

Sounder/Strobe

Power supply

Operation

Code operation

Day operation

Maintenance

Switch off

Transmission unit

Sounder/Strobe

Control

Transmission unit

VerificationTime

ZoneDetector

SwitchOff

SounderStrobe

Reset

TransmissionUnit

Control

ExtinguishingSystem

Maintenance

SwitchingPoint

Addit.Function

Silence buzzer

0

9

5 64

BZ 500 LSN

FireInternal Alarm

Next TypeDetector

Message

Action

ALARM ALARM

1 3317 49

16 4832 64

ALARM

65 81

80 96

BOSCH Security Systems

Scheibe einschlagen

Knopf drücken

0 400 LSN 0T 400 LSN 0C 410 LSN 0TC 410 LSNT 400 LSN

MSS 400 SA

MSS 400

DM 210 LSN

Feuerwehr

Scheibe einschlagen

SM 210 LSN

Feuerwehr

0T 300 GLT

FK 100 LSN NBK 100 LSN

DOW 1171

Fire Alarm

Next TypeMessage

FireExternal Alarm

NextMessage

1 2 3

7 8

CE

no yesStop

ALARM ALARM

1 3332 49

16 3348 64

Enter

Day/NightOn/Off

ResetSystem

Code

Malfunction

System

Transmission unit

Sounder/Strobe

Power supply

Operation

Code operation

Day operation

Maintenance

Switch off

Transmission unit

Sounder/Strobe

Control

Transmission unit

VerificationTime

ZoneDetector

SwitchOff

SounderStrobe

Reset

TransmissionUnit

Control

ExtinguishingSystem

Maintenance

SwitchingPoint

Addit.Function

Silence buzzer

0

9

5 64

FireInternal Alarm

Next TypeDetector

Message

Action

BOSCH Security Systems

SM 20

SM 20

1

2

3

Pos. Description

1 Conventional technology

2 LSN loop

3 Radio technology

BZ 500 LSN Fire Panel▶ Easy installation due to modular configuration

▶ Up to two loop or four stub lines can be connected

▶ For max. 254 LSN elements in up to 64 detector zonesand 16 control groups

▶ Separate alarm counter for fire alarms and test alarms

▶ Self-monitoring of processor technology (Watchdog)

www.boschsecurity.com

2 | BZ 500 LSN Fire Panel

BZ 500 LSN modules (basic version):• ZALE 10, control unit processing module• ANNE 10, connection board• Operating and display panel• Power supply

1

2

3

4

5

6

7

8

9

1 0

1 1

1 2

1 3

1 4

1 5

1 6

1 7

1 8

1 9

2 0

2 1

2 2

2 3

2 4

2 5

2 6

2 7

2 8

2 9

3 0

3 1

3 2

Alarm4 9

5 0

5 1

5 2

5 3

5 4

5 5

5 6

5 7

5 8

5 9

6 0

6 1

6 2

6 3

6 4

Alarm3 3

3 4

3 5

3 6

3 7

3 8

3 9

4 0

4 1

4 2

4 3

4 4

4 5

4 6

4 7

4 8

StörungSystem

ÜESignalgeber

Energie

BetriebCodebetriebTagbetriebRevision

SteuerungÜE

AbschaltungÜE

Signalgeber

Feuer Alarm FeuerExternalarm Internalarm

weitereMeldungsart Meldungweitere Melderweiterer Maßnahme

Erkundungszeit Code Rücksetzung TagNacht

Abschaltung Gruppe

Rücksetzung Signalgeber

Steuerung ÜE

Revision Löschbereich

Schaltpunkt

MelderinternSummer ABC1

DEF2

GHI3

STU7

VWX8

YZ9

JKL4

MNO5

PQR6

0 enter

weitereFunktion

Sirene

nein stop jaCE

1

2

3

4

5

6

7

8

9

1 0

1 1

1 2

1 3

1 4

1 5

1 6

1 7

1 8

1 9

2 0

2 1

2 2

2 3

2 4

2 5

2 6

2 7

2 8

2 9

3 0

3 1

3 2

Alarm4 9

5 0

5 1

5 2

5 3

5 4

5 5

5 6

5 7

5 8

5 9

6 0

6 1

6 2

6 3

6 4

Alarm3 3

3 4

3 5

3 6

3 7

3 8

3 9

4 0

4 1

4 2

4 3

4 4

4 5

4 6

4 7

4 8

Störung

System

Signalgeber

Energie

Betrieb

Codebetrieb

Tagbetrieb

Revision

Steuerung

ÜE

Abschaltung

ÜE

Signalgeber

Feuer Alarm FeuerExternalarm

MeldungFeuerInternalarm

weitereMeldungsart Meldung

weitereMelderweiterer Maßnahme

Erkundungszeit Code RücksetzungAnlage

Tag

Nacht

Abschaltung GruppeMelder

Rücksetzung Signalgeber

Steuerung ÜE

Revision Löschbereich

Schaltpunkt

interner Summer ABC

1DEF

2GHI

3

STU

7VWX

8YZ

9

JKL

4MNO

5PQR

6

0 enter

weitereFunktion

Sirene

Nein Stop Ja

CE

ANNE 10

BZ 500 LSN

ÜE

1

2

3

5

6

7

44

1 Front panel with operating panel and optional alarm display

2 Toroid transformer

3 Wall frame

4 Battery 12 V/40 Ah

5 Mounting location for hardware accessories

6 Cutout for cable entry

7 Cutout for TAE box

Functions

Alarm displayDisplay element is a two-line LCD display (2 x 40characters) with backlighting that is switched onautomatically when a message is received or can beswitched on manually by pressing a button.

Operation/processing of incoming messagesBoth the operation of the entire fire alarm system and theprocessing of incoming messages is carried out on theoperating and display panel of the BZ 500 LSN.

The fire panel is operated using membrane keys, each keypressed is acoustically confirmed.

The BZ 500 LSN can be equipped with two key switches,each with two switch settings (optional).

Each switch can be freely programmed, e. g..:

• Switch 1: Switch between day/night operation• Switch 2: Connect/disconnect local alarm signaling.

Recording and saving informationUp to 255 messages can be stored in an event database.

A log printer can be connected to document messages(optional).

Controlling the fire panelThe fire panel has integrated test software that continuallymonitors operation of the system. The test softwareperforms the following tasks running continuously in thebackground:

• Monitoring communication between BZ 500 LSN andLSN elements

• Monitoring the fuses• Monitoring the processor function (Watchdog)• Monitoring the program memory• Testing the RAM memory (only when starting the

system).

Further performance characteristics• Three interfaces can be connected (one interface is

included in the basic version)• Two-detector dependency possible• One-man test possible• Ground connection detection

VariantsThe German design of the BZ 500 LSN is available with orwithout the alarm display.

The BZ 500 LSN Austria has been especially configured forAustria and is a fire panel for 64 detector zones with alarmdisplay for 32 detector zones.

The following country-specific language variants ofBZ 500 LSN are available:

• English (en)• French (fr)• Italian (it)• Spanish (es)• Portuguese (pt)• Dutch (nl)• Danish (da)• Polish (pl)• Czech (cz)• Hungarian (hu)The alarm display is ready for installation for fire panels withforeign language labeling (cutout in housing and frontmembrane provided for the alarm display). The requiredATE 100 LSN detector zone display kit with red, yellow orred/yellow LEDs must be ordered separately.

BZ 500 LSN Fire Panel | 3

Certifications and Approvals

Region Certification

Germany VdS-S S 295042 BS 1000

VdS G 298002 BZ 500

DIBt Z-6.5-1630 FSA 500 LSN Basiszulassung2007-04-13

Z-6.5-1630 FSA 500 LSN Ergänzung2008-08-29

Z-6.5-1630 FSA 500 LSN Ergänzung2008-12-05

Europe CE BZ 500

CPD 0786-CPD-20358 EV Typ BZ 500

Austria PFB 007/BM-PSys/002 BZ 500 LSN

007/BM-PSys/011 BZ 500 LSN

Poland CNBOP 1908/2005 BZ 500

CzechRepublic

TZÚS 080_012700 BZ 500 LSN cz

080-001277 BS 1000

Hungary TMT TMT-50-1/2004 BZ 500 LSN

Russia GOST POCC DE.C313.B06297

MOE UA1.016.0107652-05 BZ 500, UEZ2000 B, UGM 2020 B

Slovakia EVPÚ SK08-ZSV-0024 BZ 500 LSN cz

Installation/Configuration Notes

Basic installation/configuration notes• Country-specific standards and guidelines must be

observed during the planning phase.• It is preferable to use the loop formation because of the

higher security of loop lines compared with stub lines.• It is possible to combine LSN interfaces and LSN

detectors on one loop or stub line.• Conventional detectors can be connected using an

NBK 100 LSN fire interfaces. By connecting theNBK 100 LSN, two DC primary lines are made available.

• When calculating the cable length for fire interfaces, theminimum required supply voltage must beremembered.

Installation/configuration notes in accordance with VdS/VDE• Loop formation must be according to VDE 0833 if:

- the detection area comprises more than32 detectors

- a primary line includes multiple fire sectors.• According to VDE 0833, automatic and hold up alarm

detectors must not be combined in a stub line.• In line with VDE 0833, a stub line must contain a

maximum of 10 hold up alarm detectors.• Energy balancing is performed according to VDE 0833

Part 2 and is determined using the 'UEZPRO' planningand current calculation program.

LSN system limit values per ZALE 10• Maximum 127 LSN elements (E) per loop can be

connected (LSN detector + LSN interface ≤ 127 E) per loop line

• Maximum 32 LSN elements per stub line• Maximum 100 mA current consumption (higher current

consumption disables the NVU)• Maximum cable length 1000 m

VdS limit values per ZALE 10• A maximum of 512 peripheral elements (PE) can be

connected (LSN elements + GLT elements ≤ 512 PE)• 6000 m2 maximum monitoring area• Maximum 500 m as total cable length of all detector

alarm displays• Max. 10 hold up alarm detectors per stub (VDE 0833)

Limit values for formation of loop lines or stub lines (basicversion)

E1

En En

ZALE 10

NVU 1

I II

E1

E2

En

En-1

I II

E1

ZALE 10

NVU 1

a b

21

1 Loop connection 2 Stub connection

a 1 loop: L < 1000 m b 2 stubs: ΣL < 1000 m

L = cable length

Limit values for formation of loop lines or stub lines (withhardware accessories)

E1

En En

ZALE 10

NVU 1

I II

E1

E2

En

En-1

III IV

E1

ERLE 10

NVU 2

L 3L 2L 1

L1 < 1000 m L2+L3 < 1000 m

Limit values for text entry• Short text (informational text) per alarm point (address

or sub-address dependent)- ZALE: 250 text blocks each with 19 characters- ERLE: 250 text blocks each with 19 characters

www.boschsecurity.com

4 | BZ 500 LSN Fire Panel

• Action plan (optionally address or line statusdependent)- ZALE: 15 text blocks each with 68 (28 + 40)

characters- ERLE: 15 text blocks each with 68 (28 + 40)

characters• Links for activating switch points/control groups and

alarm displays (address-, sub-address- or line status-dependent; displays flash separately for each linestatus)- 300 switch points/control groups- 16 detector points per switch point/control group- 8 line statuses per switch point/control group- 500 alarm point entries- 2000 line status entries

Power supply• The maximum power unit current (battery charge

current + standby current) is 12 V/5.4 A.• Two batteries with a maximum capacity of 40 Ah each

can be charged with the integrated power pack.• If additional power is required, a UEV 1000 universal

power supply with a 12 V/5,4 A power supply unit andtwo 40 Ah batteries can be used.

• Alternatively, the NEV 300 looped power supply withLSN chip can be used.

• The integrated BATES deep discharge protectiondisconnects the batteries from the loads as soon as thebattery voltage drops under 10.5 V.

Hardware accessory optionsThe fire panel can be installed in a 19" system.

For additional options, the UZG 1000 universal additionalhousing can be used.

TeleService can be used in conjunction with a transmissionunit (AT 2000/MOD 300).

Internal hardware accessories

Module Number Short description

ERWE 10 1 Voltage converter required for connection ofNBK 100 LSN, NTK 100 LSN, NSB 100 LSN,MSS 401. ERT 100. FK 100 LSN

ERLE 10 1 Line extension (1 loop with L<1000 m)

ERSE 10 1 Interface extension (2 x serial)

ERT 100 n Module for retrofit with loop system powersupply

SIV 28 V n For monitored protection of users connectedto the BZ 500 LSN

SM 20 max. 3* 20 mA interface for connecting DR 500 T/AV,BE 500. UGM 2020 or RUBIN

SM 24 max. 3* V24 interface for connecting peripheral devi-ces or a modem

SM 485 max. 3* Interface module for RS485 interface

AT 2000 1 Automatic selector and dialer

ATE 100 LSN max. 2 Kit with 32 LEDs (red or yellow) for alarm dis-play

Key switch max. 2 Key switch for free programming

Module Number Short description

TRN max. 2 Panel relay module with two relays/double-throw contacts for potential-free outputs

RTP max. 2 Panel relay module with four relays/double-throw contacts for potential-free outputs

ICP‑BS‑TRSP n For installation and free switching of up to5 TRN panel relay modules

BS NRK-N n 2 relays for potential-free outputs, each witha 230 V AC double-throw contact

Teleservice 1 Assembly and connection accessories for in-stallation of a transmission unit for the Tele-service

MOD 300 1 Modem incl. serial signaling interface for datatransmission in telecommunications networks

BS NTK n Panel interface for implementing switchingaddresses in the BZ 500 LSN

ICP‑LSA‑20 max. 2 Connection strip

External hardware accessories

Module Number Short description

FIBS 1 Fire department operation and informationsystem (FBF 100 LSN, FAT 2002 RE)

FBF 100 LSN 3 Fire service control panel

FBF 0760GLT 1 Fire service control panel

FAT 2002 RE 3 Fire department display panel redundant

BE 500 LSN 3 Operating panel for display and processing ofincoming messages from the fire detectionsystem

BAT 100 LSN n Display panel

FK 100 LSN +DOW 1171

n RF expansion module FK 100 LSN with opticalRF smoke detector DOW 1171

SD 1 Fire department key deposit

LA 1 Extinguishing system via LSN interface

MSS 300 n Signaling device above LSN interface

MSS 400/401 n Signaling device in LSN loop, (MSS 401 withadditional voltage supply)

SD audio/visual n Signaling device via LSN interface

TU 1 For transmitting fire alarms to the receipt sys-tem

DR 500T/AV 1 Tabletop printer (SM 20 required)

UGM 2020, RU-BIN

1 Higher-level UGM 2020, RUBIN danger detec-tion system

UEV 1000 n For additional energy requirements with a12 V/5.4 A power supply unit and space fortwo batteries

NEV 300 n Power supply with LSN chip

UZG 1000 n Universal additional housing

* Total number of interface modules (SM 20+SM 24+SM485)n = any number within the framework of the system limit values

BZ 500 LSN Fire Panel | 5

For further applications like monitored activation ofsignaling devices or extinguishing systems, refer to theFLM-20 Series Interface Modules.

Parts Included

BZ 500 LSN Fire Panel de, en, fr, it, es, pt, nl, da, pl, cz, hu

Qty. Components

1 Sheet steel housing, painted light gray

1 Operating panel with labeling in national language

1 ANNE 10 (with a V24 interface)

1 ZALE 10

1 5.4 A power supply unit

1* Front membrane for the alarm display with country-specific la-beling (without ATE 100 LSN)

* with the exception of BZ 500 LSN de

BZ 500 LSN Fire Panel de and at, with alarm display

Qty. Components

1 Sheet steel housing, painted light gray

1 Operating panel with labeling in national language

1 ANNE 10 (with a V24 interface)

1 ZALE 10

1 5.4 A power supply unit

1 ATE 100 LSN kit with 32 red LEDs

Technical Specifications

Electrical

AC line voltage 230 V AC (-15%/+10%), 50 Hz

Current consumption

• In standby mode 200 mA

• During an alarm 270 mA

• Display/illumination 200 mA

• Additional per NVU 380 mA

Power consumption 110 W (fully equipped model)

Operating voltage 11 V DC . . . 15 V DC(13.9 V DC at 30 °C)

Battery capacity 80 Ah (2x 12 V/40 Ah)

Battery charge voltage 13.8V DC

Back-up time Max. 72 h

Mechanics

Dimensions (W x H x D)

• With key switch (incl. key) 443 x 501 x 230 mm

• Without key switch 443 x 501 x 215 mm

Weight (fully equipped model)

• Without batteries 17 kg

• With 2 batteries (12 V/40 Ah) 46 kg

Color

• Housing Light-gray, RAL 9002

• Operating panel Pale gray, Bosch NCS

Environmental conditions

Protection class as per EN 60529 IP 40

Classes of equipment as perEN 60950

Class II equipment

Permissible operating temperature -5 °C . . . +45 °C

Permissible storage temperature -20 °C . . . +60 °C

Planning a Local SecurityNetwork LSN

Maximum current consumption perLSN loop

100 mA

Max. number of LSN elements

• In basic model (ZALE 10) 127

• With extension (ERLE 10) 254

Maximum LSN cable length 1,000 m

Cable for the Local SecurityNetworkLSN

J-Y (St) Y n x 2 x 0.6 orJ-Y (St) Y n x 2 x 0.8

Ordering Information

BZ 500 LSN Fire Panel de, without AlarmDisplay

BZ 500-DE

BZ 500 LSN Fire Panel de, with AlarmDisplay for 32 Det. Zones

BZ 500-MG-EAZ-DE

BZ 500 LSN Fire Panel Austria, with AlarmDisplay for 32 Det. Zones

BZ 500 A

BZ 500 LSN Fire Panel en BZ 500-GB

BZ 500 LSN Fire Panel fr BZ 500 FR

BZ 500 LSN Fire Panel it BZ 500 IT

BZ 500 LSN Fire Panel es BZ 500 ES

BZ 500 LSN Fire Panel pt BZ 500 PT

BZ 500 LSN Fire Panel nl BZ 500-MG-EAZ-NL

BZ 500 LSN Fire Panel da BZ 500 DA

BZ 500 LSN Fire Panel pl BZ 500 PL

BZ 500 LSN Fire Panel cs BZ 500 CZ

BZ 500 LSN Fire Panel hu BZ 500 HU

www.boschsecurity.com

6 | BZ 500 LSN Fire Panel

Americas:Bosch Security Systems, Inc.130 Perinton ParkwayFairport, New York, 14450, USAPhone: +1 800 289 0096Fax: +1 585 223 [email protected]

Europe, Middle East, Africa:Bosch Security Systems B.V.P.O. Box 800025600 JB Eindhoven, The NetherlandsPhone: + 31 40 2577 284Fax: +31 40 2577 [email protected]

Asia-Pacific:Robert Bosch (SEA) Pte Ltd, Security Systems38C Jalan PemimpinSingapore 577180Phone: +65 6319 3453Fax: +65 6319 [email protected]

Represented by

© Bosch Security Systems Inc. 2009 | Data subject to change without noticeT275040779 | Cur: en-US, V11, 30 Mar 2009


Recommended