of 12
7/30/2019 c19190
1/12
ConstantTemperatureEquipment
ConstantTemperatureEquipment
PolySciencePolyScience
ChillersChillers
7/30/2019 c19190
2/122
SuperiorPerformance
DependableOperation
FlexibleDesign
SuperiorPerformance
DependableOperation
FlexibleDesign
PolyScience
PolyScience RecirculatinPolyScience Recirculatin
PolyScienceChillers
SuperiorPerformance
DependableOperation
FlexibleDesign
SuperiorPerformance
DependableOperation
FlexibleDesign
When it comes to cooling your
sensitive and expensive process
equipment, you can't afford to
cut corners. You need a chiller
you can rely on day in, day
out, year after year.
And that's precisely why your
first choice for process cooling
should be a PolyScience
Recirculating Chiller. Designed
and engineered to deliver
industry-leading performance
and reliability, our 5000 and
6000 Series Chillers provide
the dependable and efficient
heat removal you need andthe advanced, user-friendly
operation you've always wanted.
Contents
Key Advantages. . . . . . . . . . . . . . . . . . . . . . . . 2
6000 SeriesRefrigerating Chillers . . . . . . . . . . . . . . 4
5000 SeriesHeating and RefrigeratingChillers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Compact Chillers . . . . . . . . . . . . . . . . . . . . . 8
Liquid-to-Air Recirculators . . . . . . . . 9
How to Size Your Chiller . . . . . . . . . 10
Chiller Options . . . . . . . . . . . . . . . . . 10
How to Select a Pump Type . . . . .11
Rack Mount Chillers . . . . . . . . . . . . 11
PolyScience Accessories . . . . . 12
Exclusive Pressure andFlow Rate Display
Only PolyScience Chillersgive you at-a-glanceaccess to process pressure
or flow rate information.
Ambient
Tracking andRemoteProbe
Capability
Optionalremote temperature probeallows set point control
based on room, machinery,or material temperature.It's ideal for ultra-precisetemperature control, suchas EDM and CNC lathing.
Built-in ProtectionAudible and visual alarmsalert you to...
Low Fluid Pressure
Low Fluid Flow
High Fluid Temperature
Low Fluid Temperature
High Ambient Temperature
Cool CommandTM
Refrigeration TechnologyReliable Cooling Even at
Elevated Ambient Temperatures
Ultra-Precise Cooling Control
Longer Compressor Life
Cool Command is an advanced refrigera-tion technology that carefully monitors
heat load to deliver only the amount ofrefrigerant needed. It permits effectivecooling even at high temperatures withoutexcessive energy consumption.
7/30/2019 c19190
3/12
Application
Chillers: Simply SuperiorChillers: Simply Superior
www.polyscience.com
Toll Free: 800-229-7569USA and Canada
Worldwide: 847-647-06
Fax: 847-647-1155
e-mail:[email protected]
Lasers
Electrical DischargeMachining (EDM)
Milling Machines
Plasma Etching
AA FurnacesConcentrator/Extractors
Condenser Cooling
Diffusion Pumps
Electron Microscope
FTIR
GC/MS
ICP
NMR Magnets
Reaction Vessels
Rotary Evaporators
Sputtering Systems
Turbo-MolecularPumps
Vacuum Systems
Welders
X-Ray Diffraction
Easy-Access Air FilterReusable filter can beremoved from either side of
unit for easy cleaning.
One-Touch ControlSetting temperature andoperation parameters is assimple as pressing andturning a single knob.
Remote OperationCapability
Remote operation throughoptional:RS232RS485Dry contact orDC voltage (12 to 24
volt signal)
Compact andPortable
Small footprint with heavy-duty locking caster wheels.
Quick-Fill
ReservoirTop-mounted fill portwith easy-access, clean-able filter makes it simple
to add cooling fluid.
Liquid LevelIndicator
Lets you quickly deter-mine when cooling fluidneeds to be added.
7/30/2019 c19190
4/124
PolyScience
The 6000 Series
Refrigerating Chiller
The 6000 Series
Refrigerating Chiller
PolyScience6000 Chillers
PolyScience 6000 Series Recirculating Chillers are designed to handle processtemperatures from -10 to 40C (14 to 104F), making them ideal for manyroutine process cooling needs. To help optimize cooling efficiency for aparticular application, they are available in a wide selection of coolingcapacities, compressor sizes, and pump types.
All models feature convenient "one-touch" temperature control and bright LED
readouts which can be easily read, even from across the room and let you checktemperature set point and fluid flow rate and/or pressure with just a quick touch.
For added operational safety, PolyScience Chillers feature audible and visualalarms that alert you instantly when operating parameters such as fluidtemperature, flow rate, fluid pressure, and ambient temperature exceedpre-set limits. There are even user-adjustable high and low temperature limits tohelp prevent unauthorized set point changes plus built-in safeties.
Other features include an easy-to-use calibration function that allows you toadjust the Chiller's temperature display to match a traceable temperaturestandard and optional interfaces for various control functions, such as remoteon/off and remote control.
Flexible Design
PolyScience RecirculatingChillers are designed to deliver
reliable performance under a
broad range of operating condi-
tions and applications. Plus for
even greater versatility, you can
select the temperature range,
cooling capacity, pump, and
control options that best meet
your heat removal needs.
-10 to 40C ProcessTemperatures
Extra-Large DigitalTemperature Readout
Digital Pressure and FlowRate Display
One-touch TemperatureControl
Push-Button CalibrationCapability
Cool CommandTM
Refrigeration Technology
Built-in EquipmentProtection
Optional Ambient TrackingProbe
Optional remote On/Offvia contact closure or12 to 24VDC
Optional RS232 or RS485
DI Water Package Available
7/30/2019 c19190
5/12
6000 ChilleSpecificatio
6000 Series Chillers
Specifications
6000 Series Chillers
Specifications
Performance specifications determined at ambient temperature of 20C/68F. For 50Hz units, derate cooling capacity and pump flow by 17%. Wetted Parts are Brass, Stainless
Steel, Polyethylene, EPDM Rubber. Cooling capacity in watts x 3.41= BTU/hr. Specifications subject to change without notice.
Specifications for Standard 6000 Series Chillers with Magnetic Drive Centrifugal Pump
Model 6206 6306 6506 6706 6106
Compressor 1/4 HP 1/3 HP 1/2 HP 3/4 HP 1 HP
Cooling Capacity @ 20C 800 Watts / 2728 BTU/hr 1200 Watts / 4092 BTU/hr 1700 Watts / 5797 BTU/hr 2500 Watts / 8525 BTU/hr 2900 Watts / 9889 BTU/hr10C 500 Watts / 1705 BTU/hr 900 Watts / 3069 BTU/hr 1100 Watts / 3751 BTU/hr 1700 Watts / 5797 BTU/hr 1950 Watts / 6649 BTU/hr
0C 200 Watts / 682 BTU/hr 500 Watts / 1705 BTU/hr 750 Watts / 2557 BTU/hr 760 Watts / 2591 BTU/hr 1000 Watts / 3410 BTU/hr
Flow Rate @ 0 PSI 4.1 gpm / 15.5 lpm 4.1 gpm / 15.5 lpm 4.1 gpm / 15.5 lpm 4.1 gpm / 15.5 lpm 4.1 gpm / 15.5 lpm
Pump Pressure 10 psi @ 0 flow rate 10 psi @ 0 flow rate 10 psi @ 0 flow rate 10 psi @ 0 flow rate 10 psi @ 0 flow rate
Shipping Weight 131 lbs / 59.4 kg 143 lbs / 64.8 kg 168 lbs / 76.2 kg 187 lbs / 85 kg 189 lbs / 85.7 kg
Volts, Hz, Amps 120V, 60Hz, 9.5A 120V, 60Hz, 10.4A 120V, 60Hz, 13.5A 208-230V, 60Hz, 9.2A 208-230V, 60Hz, 9.5A60Hz Cat. No. 082501 082511 082521 082531 082542
Volts, Hz, Amps 240V, 50Hz, 5.6A 240V, 50Hz, 5.9A 240V, 50Hz, 7.2A 240V, 50Hz, 9.2A 240V, 50Hz, 9.5A
50Hz Cat. No. 082506 082516 082526 082536 082546
Additional Specifications for "P" Series Chillers with Positive Displacement Pumps
Model 6206P 6306P 6506P 6706P 6106P
Flow Rate @ 0 PSI 1 gpm / 3.75 lpm 1 gpm / 3.75 lpm 1 gpm / 3.75 lpm 3.5 gpm / 13.2 lpm 3.5 gpm / 13.2 lpm
Pump Pressure Adjustable 20 - 100 psi Adjustable 20 - 100 psi Adjustable 20 - 100 psi Adjustable 20 - 100 psi Adjustable 20 - 100 psi
Shipping Weight 141 lbs / 64 kg 153 lbs / 69 kg 178 lbs / 81 kg 197 lbs / 89 kg 199 lbs / 90 kg
Volts, Hz, Amps 120V, 60Hz, 12.2A 120V, 60Hz, 13.1A 120V, 60Hz, 16A 208-230V, 60Hz, 11.9A 208-230V, 60Hz, 12.2A60Hz Cat. No. 082502 082512 082522 082532 082544
Volts, Hz, Amps 240V, 50Hz, 6.8A 240V, 50Hz, 7.3A 240V, 50Hz, 8.9A 240V, 50Hz, 11.9A 240V, 50Hz, 12.2A50Hz Cat. No. 082507 082517 082527 082537 082547
Catalog Numbers for "T" Series Chillers with Turbine Pumps (3.5 gpm / 13.2 lpm @ 0 psi, 2 gpm / 7.5 lpm @ 93 psi)
Model 6206T 6306T 6506T 6706T 6106T
Flow Rate @ 0 PSI 3.5 gpm / 13.2 lpm 3.5 gpm / 13.2 lpm 3.5 gpm / 13.2 lpm 3.5 gpm / 13.2 lpm 3.5 gpm / 13.2 lpm
Pump Pressure Adjustable 20 - 90 psi Adjustable 20 - 90 psi Adjustable 20 - 90 psi Adjustable 20 - 90 psi Adjustable 20 - 90 psi
Shipping Weight 143 lbs / 65 kg 156 lbs / 71 kg 181 lbs / 82 kg 197 lbs / 89 kg 199 lbs / 90 kg
Volts, Hz, Amps 120V, 60Hz, 12.2A 120V, 60Hz, 13.1A 120V, 60Hz, 16A 208-230V, 60Hz, 11.9A 208-230V, 60Hz, 12.2A60Hz Cat. No. 082503 082513 082523 082533 082543
Volts, Hz, Amps 240V, 50Hz, 6.8A 240V, 50Hz, 7.3A 240V, 50Hz, 8.9A 240V, 50Hz, 11.9A 240V, 50Hz, 12.2A50Hz Cat. No. 082508 082518 082528 082538 082548
Specifications for Standard 6000 Series Chillers with Magnetic Drive Centrifugal Pump
Additional Specifications for 6000 "P" Series Chillers with Positive Displacement Pump
Additional Specifications for 6000 "T" Series Chillers with Turbine Pump
Which pump type isright for you?See page 11.
C US
Temperature Range -10 to 40C, 14 to 104F
Temperature Stabi lity 0.1C
Reservoir Capaci ty 1.1 gallons / 4.2 l iters
Dimensions, h x w x l 225/8 x 141/2 x 275/8 in. / 57.5 x 36.8 x 70.2 cm
Inlet and Outlet 1/2 inch female NPTSupplied with 1/2 in. and 5/8 in. hose barb adapters
DI Water Package Also Available
6000 Series Chiller Specifications
7/30/2019 c19190
6/12
PolyScience
6
5000 Series
Heating and Refrigerating Chiller
5000 Series
Heating and Refrigerating Chiller
PolyScience5000 Chillers
PolyScience 5000 Series Recirculating Chillers offer the same superiorperformance, dependable operation, and flexible design of our 6000Series Chillers plus an extended operating range: -10 to 70C (14 to158F)! Ideal for more demanding temperature control applications, italso features one-touch set point control, easy-to-read temperature and
fluid flow/pressure displays, push-button calibration, and remote con-trol capability.
Also standard are all the same safety features found on the 6000.Adjustable high/low temperature limits; user-settable alarms for lowflow rate, low fluid pressure, and high ambient temperature; and
integral low liquid level and over-temperature alarms.
Extended -10 to 70CTemperature Range
Extra-Large DigitalTemperature Readout
Digital Pressure and FlowRate Display
One-touch TemperatureControl
Push-Button CalibrationCapability
Cool CommandTM
Refrigeration Technology
Built-in EquipmentProtection
Optional Ambient TrackingProbe
Optional remote On/Offvia contact closure or 12to 24VDC
Optional RS232 or RS485
DI Water Package Available
7/30/2019 c19190
7/12
5000 ChillerSpecificatio
5000 Series Chillers
Specifications
5000 Series Chillers
Specifications
Performance specifications determined at ambient temperature of 20C/68F. For 50Hz units, derate cooling capacity and pump flow by 17%. Wetted
parts are Brass, Stainless Steel, Polyethylene, EPDM Rubber. Cooling capacity in watts x 3.41= BTU/hr. Specificat ions subject to change without notice.
Additional Specifications for "P" Series Chiller s with Positive Displacement PumpsModel 5206 5306 5706 5106
Compressor 1/4 HP 1/3 HP 3/4 HP 1 HP
Cooling Capacity @ 20C 800 Watts / 2728 BTU/hr 1200 Watts / 4092 BTU/hr 2500 Watts / 8525 BTU/hr 2900 Watts / 9889 BTU/hr10C 500 Watts / 1705 BTU/hr 900 Watts / 3069 BTU/hr 1700 Watts / 5797 BTU/hr 1950 Watts / 6649 BTU/hr0C 200 Watts / 682 BTU/hr 500 Watts / 1705 BTU/hr 760 Watts / 2591 BTU/hr 1000 Watts / 3410 BTU/hr
Flow Rate @ 0 PSI 4.1 gpm / 15.5 lpm 4.1 gpm / 15.5 lpm 4.1 gpm / 15.5 lpm 4.1 gpm / 15.5 lpm
Pump Pressure @ 10 psi @ 0 flow rate 10 psi @ 0 flow rate 10 psi @ 0 flow rate 10 psi @ 0 flow rate
Shipping Weight 131 lbs / 59.4 kg 143 lbs / 64.8 kg 187 lbs / 84.8 kg 189 lbs / 85.7 kg
Volts, Hz, Amps 120V, 60Hz, 10A 120V, 60Hz, 10.7A 208-230V, 60Hz, 9.5A 208-230V, 60Hz, 9.8A60Hz Cat. No. 082601 082611 082631 082641
Volts, Hz, Amps 240V, 50Hz, 5.9A 240V, 50Hz, 6.2A 240V, 50Hz, 9.5A 240V, 50Hz, 9.8A50Hz Cat. No. 082606 082616 082636 082646
Specifications for 6000 Series Chillers with Positive Displacement Pump
Model 5206P 5306P 5706P 5106P
Flow Rate @ 0 PSI 1 gpm / 3.75 lpm 1 gpm / 3.75 lpm 3.5 gpm / 13.2 lpm 3.5 gpm / 13.2 lpm
Pump Pressure Adjustable 20 - 100 psi Adjustable 20 - 100 psi Adjustable 20 - 100 psi Adjustable 20 - 100 psi
Shipping Weight 141 lbs / 64 kg 153 lbs / 69 kg 197 lbs / 89 kg 199 lbs / 90 kg
Volts, Hz, Amps 120V, 60Hz, 12.5A 120V, 60Hz, 13.5A 208-230V, 60Hz, 12.2A 208-230V, 60Hz, 12.5A60Hz Cat. No. 082602 082612 082632 082642
Volts, Hz, Amps 240V, 50Hz, 7.1A 240V, 50Hz, 7.6A 240V, 50Hz, 12.2A 240V, 50Hz, 12.5A50Hz Cat. No. 082607 082617 082637 082647
Specifications for 6000 Series Chillers with Turbine Pump
Model 5206T 5306T 5706T 5106T
Flow Rate @ 0 PSI 3.5 gpm / 13.2 lpm 3.5 gpm / 13.2 lpm 3.5 gpm / 13.2 lpm 3.5 gpm / 13.2 lpm
Pump Pressure Adjustable 20 - 90 psi Adjustable 20 - 90 psi Adjustable 20 - 90 psi Adjustable 20 - 90 psi
Shipping Weight 143 lbs / 65 kg 156 lbs / 71 kg 197 lbs / 89 kg 199 lbs / 90 kg
Volts, Hz, Amps 120V, 60Hz, 12.5A 120V, 60Hz, 13.5A 208-230V, 60Hz, 12.2A 208-230V, 60Hz, 12.5A60Hz Cat. No. 082603 082613 082633 082643
Volts, Hz, Amps 240V, 50Hz, 7.1A 240V, 50Hz, 7.6A 240V, 50Hz, 12.2A 240V, 50Hz, 12.5A50Hz Cat. No. 082608 082618 082638 082648
Specifications for Standard 5000 Series Chillers with Magnetic Drive Centrifugal Pump
Additional Specifications for 5000 "P" Series Chillers with Positive Displacement Pump
Additional Specifications for 5000 "T" Series Chillers with Turbine Pump
Which pump type isright for you?See page 11.
Temperature Range -10 to 70C, 14 to 158F
Temperature Stabil ity 0.1C
Reservoir Capaci ty 1.1 gallons / 4.2 li te rs
Dimensions, h x w x l 225/8 x 141/2 x 275/8 in. / 57.5 x 36.8 x 70.2 cm
Inlet and Outlet 1/2 inch female NPTSupplied with 1/2 in. and 5/8 in. hose barb adapters
DI Water Package Also Available
5000 Series Chiller Specifications
C US
7/30/2019 c19190
8/12
PolyScience
8
Compact Chillersand Recirculators
Additional Cooling Solutions
Compact Chillers
Additional Cooling Solutions
Compact Chillers
8
Performance specifications determined at ambient temperature of 20C/68F. For 50Hz units, derate cooling capacity by 17%.
Cooling capacity in watts x 3.41 = BTU/hr. Specifications subject to change without notice.
Model 612
-10 to 40C temperature range
0.2C temperature stability
Analog temperature control
High efficiency heat exchanger
Self-priming centrifugal pump
Rack mount option available withfull extension slides for installationin a standard 19 inch rack
Model 5005
-5 to 50C temperature range
0.1C temperature stability
Compact design
Low pressure centrifugal pump
Sealed reservoir prevents evapora-tion, minimizes algae growth suitable for open or closed loopcooling applications
Cool CommandTM refrigerationtechnology
Model 5005 Specifications
Temperature Range -5 to 50C / 23 to 122F
Temperature Stability 0.1C
Readout LED
Readout Selectability C or F
Cooling Capacity @ 20C 450 Watts / 1535 BTUs/hr10C 350 Watts / 1194 BTUs/hr0C 150 Watts / 511 BTUs/hr
Flow Rate @ 0 PSI 3 gpm / 11.4 lpm
Pump Pressure 5 psi @ 0 flow rateReservoir Capacity 0.46 gal. / 1.75 liters
Reservoir Drain Yes
Inlet and Outlet 1/2 inch female NPT
Heater 350 Watts
Over Temperature Safety Yes
Low Liquid Safety Yes
Dimensions, 201/2 x 12 x 161/2 in.l x w x h 52 x 30.5 x 41.9 cm
Shipping Weight 80 lbs / 36.3 kg
Cat . No. 120V, 60Hz, 6.5A 082590
Cat . No. 240V, 50Hz, 3.2A 082595
Specifications for Model 5005
Temperature Range -10 to 40C / 14 to 104F
Temperature Stability 0.2C
Cooling Capacity @ 20C 190 Watts/ 648 BTUs/hr10C 140 Watts / 478 BTUs/hr0C 90 Watts / 307 BTUs/hr
-10C 45 Watts / 154 BTUs/hr
Flow Rate @ 0 PSI 1.43 gpm / 5.4 lpm
Reservoir Capacity 0.1 gal. / 0.4 liters
Inlet and Outlet 3/8 inch female NPT
Dimensions, 181/2 x 12 x13 in.l x w x h 47 x 30.5 x 33 cm
Shipping Weight 57 lbs / 25.8 kg
Cat. No. 120V, 60Hz, 7A 082550
Cat. No.240V, 50Hz, 3.5A 082551
Specifications for Model 612
Rack mount installation kit
for a 19 inch rack. Order
Cat. No. 505-040
PolyScience offers a wide
selection of temperature
control solutions. For cooling
applications that don't require
the power or performance of
6000 and 5000 Series Chillers,
PolyScience offers compact
chillers and liquid-to-air
recirculators.
7/30/2019 c19190
9/12
Application
Additional Cooling Solutions
Liquid-to-Air Recirculator
Additional Cooling Solutions
Liquid-to-Air Recirculator
0 0.5 1.0 1.5 2.0 2.5
Flow (GPM)
22C
20C
18C
16C
14C
12C
10C
8C
6C
4C
2C
0C
T(Water)
500W
1000W
2000W
3000W
4000W
Positive Displacement Pump Turbine Pump
At 20C/68F Ambient C US
Performance specifications determined at ambient temperature of 20C/68F. For 50Hz units, derate cooling capacity and pump flow by 17%.
Cooling capacity in watts x 3.41 = BTU/hr. Specifications subject to change without notice.
Model 3370 Economical liquid-to-air cooling
handles fluid temperatures up to 77C
For applications where the cooling fluidtemperature is higher than ambient andcontrol isn't required
Positive displacement pump, reusable inlinefluid filter (optional turbine pump available)
Built-in low liquid indicator
Model 340
Economical liquid-to-air cooling handles fluid temperatures up to 50C
For applications where the coolingfluid temperature is higher than ambi-ent and control isn't required
Magnetic drive centrifugal pump
Built-in low liquid indicator
Supplied with mounting plates forinstallation in a standard 19 inch rack
Includes 1/4 in. tube and 1/4 in. flowhose barb fittings
Operating Temperature Range Ambient to 77C / 170Fmaximum
Cooling Capacity @ 20C 4000 Watts / 13,640 BTU/hrFlow Rate @ 0 PSI 1.5 gpm / 5.6 lpm
Pump Pressure Adjustable 20-100 psi
Reservoir Capacity 1.3 gal. / 4.8 liters
Inlet and Outlet 1/2 inch female NPT
Dimensions, 15 x 15 x 25 in.l x w x h 38 x 38 x 63.5 cm
Shipping Weight 76 lbs / 31.8 kg
Cat. No.120V, 60Hz, 5.5A PD Pump 040305
Cat. No. 240V, 50Hz, 2.75A PD Pump 040306
Cat. No. 120V, 60Hz, 7A Turbine Pump 040307
Cat. No. 240V, 50Hz, 3.5A Turbine Pump 040308
www.polyscience.com
Toll Free: 800-229-7569USA and Canada
Worldwide: 847-647-06
Fax: 847-647-1155
e-mail:[email protected]
Model 340 Specifications
Operating Temperature Range Ambient to 50C / 122Fmaximum
Cooling Capaci ty @ 20C 400 Watts / 1364 BTU/hr
Reservoir Capacity 0.07 gal. / 0.25 liters
Flow Rate @ 0 PSI 0.2 gpm / 0.75 lpm
Pump Pressure 5.2 psi @ 0 flow rate
Low Flow Indicator yes
Inlet and Outlet 1/4 in. ID, 1/4 in. flowquick disconnect
Dimensions, 8 x 151/8 x 83/4 in.l x w x h 20.3 x 38.4 x 22.2 cm
Rack Mount Width 19 in. / 48.3 cm
Shipping Weight 24 lbs / 10.9 kg
Accessory Outlet Current 3.0A @ 120V maximum1.5A @ 240V maximum
Volts, Hz, Amps 120V, 60Hz, 3.5A240V, 50Hz, 2.0A
Cat. No. 120V / 240V 040310
Specifications for Model 340
Bioreactors
CCD Camera
Closed LoopApplications
Condensers
DensitometersElectron Microscope
FTIR
General Lab Cooling
GC/MS
ICP
IncubatorWater Jackets
Lasers
Rotary Evaporators
Small Injection Mold
Small Peltier Device
Spectrophotometers
Specifications for Model 3370
7/30/2019 c19190
10/12
PolyScience
How To SizeYour Chiller
Select the PolyScience Chiller
That's Right For You
Select the PolyScience Chiller
That's Right For You
10
Correctly sizing your PolyScience Chiller maximizes operating efficiency and economy. The opti-mum size is based on the amount of heat the application is generating plus the power needed tomaintain temperature under varying loads. The following formula is used to calculate heat load:
Watts =[T x (K)]
S
Where:
T = The difference between the incoming and
outgoing fluid temperature of the device.
K = Conversion constant for the density andspecific heat of water.Use 4,186 when calculating load in C;
use 2,326 when calculating load in F.
S = The number of seconds needed to fill aone liter container.
Additional considerations:
1. For ambient temperatures above 20C, add
1% to the calculated wattage for each 0.5Cabove 20C.
2. Add 20% to the calculated wattage if oper-ating with 50 Hz power.
3. Add 10% to the calculated wattage if operat-ing at high altitude or at line voltages consis-tently below the rated voltage.
4. Future cooling needs and/or variability ofthe heat output of the existing device.
Ambient Tracking For set point controlbased on room, machinery, or material tem-perature. Platinum RTD sensor with stainlesssteel sheath 3/16 dia. x 3 in. long (.47 dia. x 7.6cm). Probe cable ends in DB9 female plug.
Order in 10 ft. (3 m), 25 ft. (7.6 m) or 50 ft.(15.25 m) cable lengths. Custom lengths or
standard 4 inch front panel mount with clipavailable.Order option code: AA
Dry Contact Control Permits remoteOn/Off via contact open or contact closure(contact open is standard with a male connector)Order option code: HH
DC Voltage Control Permits remote On/Offvia 12 to 24 volt DC signal (male connector)
Order option code: GG
DI Water Package With DI compatiblewetted partsOrder option code: PP
RS232 and RS485 Communication PortsRS232 - Order option code: MRS485 - Order option code: O
Low Fluid Alarm/Shut Down Provides visu-al and audible alarm for low fluid level andshut down for pump protectionOrder option code: X1
PolyScience offers a variety
of option packages to create
a chiller that specifically fits
your application needs.
Customization and modifica-
tion inquiries are welcome.
PolyScience also offers a varietyof custom options to meet specific require-ments including:
Pumps
Filters
Tubing
Fittings
Control Options
Factory InstalledChiller Optionsfor Chillers on
pages 4 - 7
No Reservoir - For open loop applications withexternal reservoir.Order option code: UU
External Sensor - Tracks the fluid temperature of
the chiller line at a remote point. The probesenses the temperature at the location and com-pensates for any thermal loss over the distance.Order option code: CC
Remote Control - Control the temperature ofyour process in applications where the chiller isthe primary loop and your process is the sec-ondary loop. The sensor, located in the second-ary loop, will allow the chiller to control thetemperature of your process by adjusting thechiller fluid temperature accordingly.Order option code: QQ
Where:
7/30/2019 c19190
11/12
How To Select
A Pump Type
How To Select
A Pump Type
Rack MounChillers
Magnetic DriveCentrifugal Pump
Magnetic Drive Centrifugal Pumpsproduce high flow at low pressure, arevery quiet, and require little mainte-nance. The fact that fluid flow can be
restricted without pump damage makesthis pump suitable for many applications.
Chillers equipped with a centrifugalpump attached to a device with a built insolenoid valve to shut off cooling flowalso require an external bypass. See
Accessories, page 12.
Positive DisplacementPump
Positive Displacement Pumps producemoderate flow at high pressure and aremost suited to applications wheregreater head pressure is needed, such as
applications where fluid must bepumped some distance or where in-linepressure is required to activate flowdevices.
Turbine Pump
Turbine Pumps are typically used inapplications requiring operation withhigher head pressures (90 psi) and lowto moderate flow rates (1 to 9 gpm).
GPM
LPM
16
12
8
4
0
0 2 4 6 8 10 12 14 16
0 8.8 17.6 26.4 35.2 44.0 52.8 61.6 70.5
P
SI
6
10
14
2
GPM
LPM
100
75
50
25
0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
0 2.2 4.4 6.6 8.8 11.0 13.2 15.4 17.6
PSI
GPM
LPM
100
75
50
25
0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
0 2.2 4.4 6.6 8.8 11.0 13.2 15.4 17.6
P
SI
6206,6306,6506,5206,5306
6206, 6306, 6506,6706, 6106,
5206, 5306, 5706,5106
6706,6106,5706,5106
6206,6306,6506,
5206,5306
Rack Mounted ChillersPolyScience also offers specially-designed chillers forapplications where, for either convenience or necessity,the cooling equipment needs to be installed in a standard19 inch rack. For information on this rack mountingoption or to discuss a unique cooling requirement, suchas an extended temperature range or special electricalrequirement, contact PolyScience customer service.
PolyScience also offers a wide range of OEM refrigerationsolutions, from private labeled cooling equipment to
custom-designed refrigeration sub-assemblies.
PolyScience Chillers offer a choice of pump to fit your application needs
A rack mount chiller option is available
6706,6106,5706,5106
Pump TypeSpecificatio
7/30/2019 c19190
12/12
AboutPolyScience
PolyScience is a leading manufacturerof Refrigerated Circulators, HeatingCirculators, Chillers, Heat Exchangers,Water Baths, and custom temperaturecontrol equipment for industrial andlaboratory use. We have been provid-ing customers worldwide with preci-sion temperature control equipmentsince 1963 and serve a diverse range ofindustries, including:
Biotechnical
Chemical
Industrial Laser
Medical
Pharmaceutical
Clinical
Beyond our comprehensive line ofstandard temperature control products,PolyScience also offers customdesigned heating and cooling equip-ment. If you have a special applicationor specific product need, our experi-enced design, engineering, and techni-
cal staff will be happy to review yourapplication and design a product thatmeets your exact requirements.
ISO 9001:2000 Certified
Division of Preston Industries, Inc.
www.polyscience.com
6600 West Touhy Avenue, Niles, IL 60714
PolyScience
RS232 Adapter Kit Available for PolyScience
6000 and 5000 Chillers. Includes hardware,
installation and operation instructions.
Cat. No. 510-298
External Pressure Reducer For chillers
with a positive displacement or turbine pump.
Reduces chiller output to an adjustable rangeof 10-45 PSI. Cat. No. 060302
External Bypass For chillers with a centrifugal
pump and attached to a device with a built-in
solenoid valve to shut off cooling flow.
Connects to the inlet and outlet, allowing
bypass flow when main flow is stopped.
Cat. No. 510-147
Model 612 Rack Mount Kit includes 19 in.
standard rack mount bracket and hardware.
Cat. No. 505-040
Hose Barb Tubing Adapters for PolyScience6000 and 5000 Chillers. Two sets: 1/2 in. (1.27
cm) NPT x 5/8 in. (1.58 cm) and 1/2 in. NPT x1/2 in. Cat. No. 510-288
90 Elbow Tubing Adapters for PolyScienc
Compact Chillers and Liquid-to-Air Recirculato
Two sets: 1/2 in. (1.27 cm) NPT x 5/8 in. (1.5
cm) and 1/2 in. NPT x 1/2 in.
Cat. No. 510-213
Tubing Insulation Per yard (0.9 m)5
/16 in. (0.8 cm) I.D. Cat. No. 0603091/2 in. (1.27 cm) I.D. Cat. No. 060311
Lab Algaecide helps keep circulating fluid
clean, odor free, and resistant to black algae
Stainless steel compatible. Use 10 to 15 drop
per gallon. 8 oz. (236 ml) dispenser bottle
treats approximately 400 gallons (1514 liters)
Cat. No. 004-300040
PolyThermTM Fluid Start Up Kit Lab grade
Ethylene Glycol mixed 50/50 with distilled
water, and lab algaecide. Five each 1/2 gallo
containers. Cat. No. 004-300060
Ethylene Glycol Lab grade clear antifreeze
fluid used for low temperatures.
1 gallon container Cat. No. 060340
010144 5M R 6
DURACHILLTM ChillersIndustrial capacity chillers
for dependable heat removal.
From 1.5 to 25 HP, up to
86,000 watts of cooling.
CirculatorsOver 30 models, with tem-
perature ranges of -45 to
200C, Precise control and
stability.
Water BathsSeven models, capacities
of 2L to 28L, temperature
range of ambient +5 to
100C.
PolyScience Product Brochures
PolyScience Accessories
Replacement Air Filter Washable filter
helps keep chiller condenser clean for opti-
mal performance. Cat. No. 305-001