Maximizing the Potential of
UHPLC/HPLC Analyses
Resolution
Intelligence
Stability
SensitivityIntelligent data solutions, including a new peak calculation method for enhanced separation power, accelerate workflows.
The ultimate platform for high-sensitivity UHPLC and HPLC detection.
Enhanced peak resolution achieved by minimizing external column dispersion.
Superior stability for UHPLC/HPLC analyses.
Ultra High Performance Liquid Chromatograph
-PDeAi
Utilizing patented technologies, and driven by customer input, Shimadzu has developed
the Nexera X2 series to deliver superior, real-world performance across a wider
application range, while delivering unparalleled flexibility and reliability in UHPLC/HPLC
analyses. With no limits and no compromises, the Nexera X2 achieves a new milestone in
the evolution of liquid chromatography.
4
Nexera Quaternary system Nexera Method Scouting system
Nexera MP system Nexera TQ system and Nexera SQ system
Nexera SR system Nexera UHPLC/HPLC system
Nexera X2 SeriesA full range of configurations to meet your applications needs…
features superior sensitivity, resolution and stability. * offers new separation technology.
is a flexible quaternary gradient system that is HPLC and UHPLC compatible.
offers comprehensive method development using 96 combinations of mobile phases and columns.
offers ultrafast LC/MS and LC/MS/MS analysis.
is an LC/MS frontend HPLC for high-throughput analysis of multiple samples.
enables switching from UHPLC to HPLC in a single system using a selection of mixers and columns.
Nexera SR system
Nexera Quaternaryyy system
Nexerarara MP system
Nexera UHPLC/HPLC systemN
*Intelligent Peak Deconvolution Analysis
-PDeAi
The CBM-20A enables system control via a network. The CBM-20A allows for various
system configuration to meet different laboratory workflows.
Nexera X2 Component
Ultra-high-sensitivity and high-resolution detector
Th
sys
The SPD-M30A realizes ultra-high sensitivity and minimized
dispersion, supporting the new separation calculation
method, . The temperature-controlled optics provide
stable baseline for genuine UHPLC analysis.
*Intelligent Peak Deconvolution Analysis
SIL-30ACMP
SPD-M30A
Upgradable to binary gradient and quaternary gradient, the
LC-30AD also supports solvent blending for automated
mobile phase preparation.
LC-30AD
SIL-30AC SIL-30AC / Rack Changer II
CTO-30ASCTO-30A CTO-20AC
U
CBM-20A
D e t e c t o r
A u t o s a m p l e r
C o l u m n o v e n
S o l v e n t d e l i v e r y u n i t
Multifunctional autosampler;
pretreatment and loop injection
are available
Features control to a maximum 150°C
(Max column length: 150 mm)
Large space for placing multiple
columns and valves
(Max column length: 300 mm)
Compact column oven for LC/MS
front end
(Max column length: 50 mm)
Maximum 12 plates can be set with this
combination
Open-access autosampler with
maximum 6 plates
5Ultra High Performance Liquid Chromatograph
-PDeAi
Intelligence in UHPLC/HPLC Analysis
Complete Separation of Co-eluted Peaks by Intel l igent Peak Deconvolution Analysis ( )
Example1: Remove tai l ing peak
Example2: Impurity peak extracted from co-eluted peak
enables the extraction of a single peak from co-eluted peaks by utilizing difference in spectra by a few steps. The new separation
method removes discussion of integration methods for co-eluted peaks. The also helps detect impurity peaks in a target peak.
Vertical separationBaseline separation
Removes peak integration ambiguities
Step 2Extraction of single peak signal using
the difference between each spectrum
Step 1Analysis
Step 3Display of single component
representative peak
Component A
Component B
AU
1
2
nm
Component A
shows extraction of component B.
shows extraction of component A.
::
Component B
0.00 0.25 0.50 0.75 1.00 1.25 min
0.5 mg/L spiked
0.488 mg/L measured
(98% accuracy)
0.00 0.25 0.50 0.75 1.00 1.25 min
Target peak
Tailing peak
The target peak is on the tailing peak
This peak looks a single peak.
Remove the tailing peak!!
By removing the main peak, the impurity peak appears on the chromatogram!!
0.22 0.24 0.26 0.28 min0.22 0.24 0.26 0.28 min
Peak purity curve
1
2
12
-PDeAi-PDeAi
-PDeAi
-PDeAi
-PDeAi
6
Ultimate Sensitivity
Ultra High Performance Liquid Chromatograph
Achieving maximum sensitivity
Column Shim-pack XR-ODSⅢ (50 mmL. × 2.0 mmI.D., 1.6 μm)
Flow rate 0.6 mL/min
Main peak propyl 4-hydroxybenzoate
0.005% Impurity peak ethyl 4-hydroxybenzoate
μAU
mAU
1750
600
S/N 9.53
0.5 0.7 0.9 min
400
200
0
1250
750
250
0
0.0 0.5 1.0 min
Mai
n pe
ak
0 50.5 0 70.7 0 90.9 m
Impurity peak
Section of capillary cell
The SR-Cell features high-sensitivity and low-dispersion by adopting total reflection capillary cell.
High-sensitivity and high-resolution
SR-Cell
The SPD-M30A photodiode array detector adopts the high-sensitivity and low-dispersion capillary cell, SR-Cell, which achieves a
0.4×10-5 AU noise level. The SPD-M30A offers ultimate in UHPLC analysis, realizing high-sensitivity and high-resolution.
The excellent sensitivity and wide dynamic detection range enables simultaneous analysis of a main ingredient and impurity of
0.005% content.
The SR-Cell is available for UHPLC and HPLC, realizing high-sensitivity analysis across a wide analytical range.
0.0 1.0 2.0 3.0 4.0 min
0.0 5.0 10.0 15.0 20.0 25.0 min
Conditions
Conditions
Column
Time program
Flow rate
Shim-pack VP-ODS (150 mmL. × 4.6 mmI.D., 4.6 μm)
2% (0 min)→100% (30 min)
1.0 mL/min
Conditions
Column
Time program
Flow rate
Shim-pack XR-ODSⅡ (75 mmL. × 3.0 mmI.D., 2.2 μm)
2% (0 min)→100% (4.2 min)
1.3 mL/min
SR Cell
The SR-Cell features high-sensitivity by adopting total reflection capillaryThe SR-Cell features high-sensitiv
Section of capillary cellSection of capillary cell
7
Maximized Resolution
Superior peak shape for maximum peak resolution
In ultrafast analysis, external column dispersion affects peak resolution. The SR-Cell in the SPD-M30A has minimized the cell volume to
realize excellent peak shape with higher peak resolution, supporting genuine UHPLC analysis.
Superior spectrum resolution and l inearity
The SPD-M30A provides unrivaled spectrum resolution by adopting an optimized optic system. In addition, the new signal treatment
technology realizes excellent spectrum linearity across a wide area from low concentration to high concentration. The SPD-M30A supports
analyses, such as purity analysis, that require a wide dynamic range.
Nexera SR system for high-sensitivity and high-resolution
Nexera SR system is configured with the new SPD-M30A photodiode array detector.
The new peak calculation technology, , proposes a new approach for separation
of co-eluted peaks and extraction of impurity peaks from main peaks. The superior
sensitivity and resolution expand the range of UHPLC analyses.
*As of November 2012, according to Shimadzu research.
A Benzene spectrum is often used for evaluation of spectrum resolution.
The SPD-M30A shows world’s highest spectrum resolution, B/A=2.90*.
The SPD-M30A shows excellent spectrum linearity in the analysis of
caffeine samples with different concentrations.
Column Shim-pack XR-ODS III(50 mmL. × 2.0 mmI.D., 1.6 μm)
Flow rate 0.6 mL/min
Peak No.
Tailing factor (Tf5%)
Nexera X2 Vendor A
1
2
3
1.309
1.297
1.273
1.546
1.486
1.432
0.20 0.25 0.30 0.35 0.40 0.45 0.50 min
peak
1
peak
2
peak
3
Nexera X2
Vendor A UHPLC
230 240 250 260 270 280 nm
0
B
A
B/A=2.90
Caffeine 100 mg/LCaffeine 1000 mg/L
250 300 350 nm(Normalize)
mAU
Similarity 0.9998
-PDeAi
Nexera SR system
8
Unrivaled Stability
Ultra High Performance Liquid Chromatograph
Baseline stabil ization by temperature-controlled TC-Optics
The SPD-M30A adopts the new temperature-controlled TC-Optics with the SR-Cell that has an optimized heat exchange inlet pipe.
These features achieve faster stabilization times low external dispersion for UHPLC analysis.
The faster stabilization shortens the “wait time” for analysis, thereby increasing total analytical throughput.
Stable performance against room temperature shift
The SPD-M30A incorporates TC-Optics to achieve a more stable baseline against room temperature shifts.
Flow rate 0.5 mL/min
Mobile phase Methanol
Detector PDA 254 nm
Temperature RT
Vendor A PDA detector
SPD-M30A
0 10 20 30 40 50 min
-40
-30
-20
-10
10
0
mAU
The SPD-M30A shows a stable baseline faster after
startup while the detector from vendor A shows
baseline drift during 1 hour.
le the detector from vendor A shows
ft during 1 hour.
SPD-M30A
Flow rate 0.5 mL/min
Mobile phase Methanol
Detector UV 254 nm
0 100 200 300 400 500 600 min-20
-15
-10
-5
0
5
10
15
20
25
mAU
254 nm
Room temperature
Vendor A PDA detector
SPD-M30A25°C
30°C
9
Ultimate Flexibility
The modular nature of Nexera X2 allows a
solvent blending function that can mix
solvents according to desired ratios. This
function enables dilution of solvent, buffer
preparation and modifier addition for mobile
phase preparation.
Buffer pH can be optimized using the solvent
blending function as shown to the right
chromatograms. The function is a useful tool
for optimizing mobile phase conditions in
method development.
Measured pH of mobile phase prepared by solvent blending
Automation of mobile phase preparation by solvent blending function
The solvent blending function can be added to a Nexera UHPLC/HPLC switching system
by upgrading the configuration. The system supports all processes from method
development to method transfer from HPLC to UHPLC.
Combination of UHPLC / HPLC Switching system and solvent blending
Pump1
Pump2
A
B
C
D
A
B
C
D
Y
X
85%
10%
50%
20%
5%
25%
5%
0%
Solvent BlendingAutomated mobile phase preparation
Binary GradientGradient elution by prepared solvents
0.0 1.0 2.0 3.0 4.0 min
Blending 1
1, 2, 3
pH 3.0A / B = 6 / 4
0.0 1.0 2.0 3.0 4.0 min
Blending 2
1
23
pH 7.2A / B = 2 / 8
1, Benzoic ac id2, Sorbic ac id3, methyl 4-hydroxybenzoate
Blending 1 3.010
Blending 2 7.192
3.004
Solvent blending Manual preparation
7.191Blending 1 A / B = 6 / 4
Blending 2 A / B = 2 / 8
Pump Y solvent Methanol
A; 20 mmol/L phosphoric acid aqueous solutionB; 20 mmol/L disodium hydrogen-phosphate
Pump X solvent
em
lvent blending
Nexera UHPLC/HPLC system
10
Ultra High Performance Liquid Chromatograph
Nexera X2 autosamplers support ultrafast injections to increase analytical throughput. In particular, the SIL-30ACMP achieves a 7-second injection
time and a 14-second cycle time, making it ideally suited for ultrafast analysis.
Ultrafast 7-second injection and 14-second cycle t ime
The Nexera X2 autosamplers, SIL-30AC and SIL-30ACMP, provide near-zero carryover. The improved design maintains a low carryover level, even
during long-term usage, to ensure reliable analysis.
Both the SIL-30AC and SIL-30ACMP support the use of multiple rinse
solvents for rinsing the needle’s outer surface and inner surface to
thoroughly minimize carryover.
The carryover level was extremely low even after 30,000 injections.
Minimizing carryover with multiple r inse solvents
Enhanced UHPLC Reliability
0
25000
50000
75000
100000
125000
1:235.40>86.10(+)2:256.10>167.10(+)3:281.10>86.10(+)
0.0 0.25 0.5 0.75 1.0 min
14 sec
Contact surfaces of needle and needle port
where carryover is likely to occur
Port section is rinsed by any of the rinse solutions(1 to 3 solutions)
Discharge to drain port
Needle port(schematic diagram)
Drain
Multi-rinse mechanism canaccommodate up to 4 solutions
Sample loop
Needle
Rinse ports
For rinsing needle surface andinner surface (3 types)
For rinsing needlesurface (1 type)
R0 R1 R2 R3
Shim-pack XR-ODS II (30 mmL. × 1.5 mmI.D., 2.2 μm) Column
Flow rate 1.2 mL/min
Event #
1
2
3
Q1 m/z
235.4
256.1
281.1
Q3 m/z
86.1
167.1
86.1
Compound
Lidocaine
Diphenhydramine
Imipramine
Shim-pack XR-ODS III (150 mmL. × 2.0 mmI.D., 2.2 μm)Column
Mobile phase Water / Methanol = 7 / 3
Flow rate 0.4 mL/min
Sample Caffeine 4000 mg/L
0.0 0.5 1.0 1.5 2.0 2.5 min
-25
0
25
50
75
100
125
150
175
200
mAU
2.25 2.50 2.75 min
0
250
500
750uV
0.00018%
11
Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol “TM” or “®”.Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.
For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.
© Shimadzu Corporation, 2012www.shimadzu.com/an/Printed in Japan 3655-08220-30ANS