POWER / FUSE PANEL DSX1 or E1 IMA LIM DS3 or E3 LIM Xedge LIMs (Rear View) LIM Slots LINK 0-7 LINK 8-15 AL IS DSX1-IMA LINK 0-7 LINK 8-15 AL IS E1-IMA DS3-2C LINK 0 TX (SELV) RX TX RX LINK 1 L0 IS OS L1 LB RD BL LS YL ER DSX1/DS3 LIMs Connector Panels E3-2C LINK 0 TX (SELV) RX TX RX LINK 1 L0 IS OS L1 LB RD BL LS YL ER Xedge PCL (Front View) E1/E3 LIMs Connector Panels Xedge PCL/IMA+ Installation Checklist GDC P/N 032R401-V722-A1, Issue 1 (May 2009) A F F C B E D CABLE CONNECTIONS Belden COAX cable (or equivalent) DS3/E3 LIM Front Panel Belden 9054 (or equivalent) F DS3-2C or E3-2C LIM F E1 IMA+ LIM E D C B A DSX1 IMA+ LIM Xedge PCL User (LAN) Port Xedge PCL Mgmnt (WAN) Port Xedge Chassis Craft Port RJ45 Ethernet straight-through shielded cable with RJ45 to DB9 female adapter GDC 027H251-005 RJ45 Ethernet straight-through shielded cable T1/E1 50-pin RJ48M to 8-port RJ48C breakout cable assembly (See manual for other distribution options.) GDC 027H251-XXX S-032H016-001 Reference Connector Location Description of Cabling Cable Part Number Connector Details GDC 029H015-001 PCL Front Panel Xedge Chassis Front Panel A B C or For all connector interfaces, refer to the manual for additional information on EMI suppression requirements. D E or 1 2 3 4 5 6 7 8 DSX1/E1 IMA LIM Front Panel 8-Port Breakout Cable Assy
Transcript
Page 1: CABLE CONNECTIONS - GDC · INITIALIZATION - ALL SITES Xedge PCL/IMA+ Installation Checklist GDC P/N 032R401-V722-A1, Iss. 1 (May 2009)-Select M,39,0,E -Check that Option 2 Phy Framer

POWER / FUSE PANEL

DSX1 or E1 IMA LIM

DS3 or E3 LIM

Xedge LIMs(Rear View)

LIMSlots

LIN

K 0-7

LIN

K 8-15

AL

IS

DSX1-IMA

LIN

K 0-7

LIN

K 8-15

AL

IS

E1-IMADS3-2C

LIN

K 0

TX

(SE

LV)

RX

TX

RXLIN

K 1

L0

ISO

S

L1

LB

RD

BL

LS

YL

ER

DSX1/DS3 LIMsConnector Panels

E3-2C

LIN

K 0

TX

(SE

LV)

RX

TX

RXLIN

K 1

L0

ISO

S

L1

LB

RD

BL

LS

YL

ER

Xedge PCL(Front View)

E1/E3 LIMsConnector Panels

Xedge PCL/IMA+ Installation ChecklistGDC P/N 032R401-V722-A1, Issue 1 (May 2009)

A

F

F

CB

E

D

CABLE CONNECTIONS

Belden COAX cable (or equivalent)

DS3/E3 LIMFront Panel

Belden 9054(or equivalent)

F

DS3-2C or E3-2C LIMF

E1 IMA+ LIMEDCB

A

DSX1 IMA+ LIM

Xedge PCL User (LAN) Port

Xedge PCL Mgmnt (WAN) Port

Xedge Chassis Craft Port RJ45 Ethernet straight-through shielded cable with RJ45 to DB9 female adapter GDC 027H251-005

RJ45 Ethernet straight-through shielded cable

T1/E1 50-pin RJ48M to 8-port RJ48C breakout cable assembly (See manual for other distribution options.)

GDC 027H251-XXX

S-032H016-001

Reference Connector Location Description of Cabling Cable Part Number

Connector Details

GDC 029H015-001

PCLFront Panel

Xedge Chassis Front PanelA

B Cor

For all connector interfaces, refer to the manual for additional information on EMI suppression requirements.

D Eor

1 2 3 4 5 6 7 8

DSX1/E1 IMA LIM Front Panel

8-PortBreakout

Cable Assy

Page 2: CABLE CONNECTIONS - GDC · INITIALIZATION - ALL SITES Xedge PCL/IMA+ Installation Checklist GDC P/N 032R401-V722-A1, Iss. 1 (May 2009)-Select M,39,0,E -Check that Option 2 Phy Framer

INITIALIZATION - ALL SITES

Xedge PCL/IMA+ Installation ChecklistGDC P/N 032R401-V722-A1, Iss. 1 (May 2009)

-Select M,39,0,E -Check that Option 2 Phy Framer is set to DS3-Change Option 3 Cell delin to HEC or PLCP-Change Option 4 to scrambled or not (must match at LIM and connected device.)-Check that Chip Type is set to SUNI QJET-Set Option 10 Reconfigure to yes

-Select M,70,3,3,G[link number],E -Change Option 2 to Enable or Disable -Change Option 3 to scrambled or not (must match at LIM and connected device.)-Change Option 4 Framing to sf or esf -Set Option 5 Line Code to ami or b8zs -Set Option 6 Line length (A through F)

-Select M,39,0,E -Check that Option 2 Phy Framer is set to E3-Change Option 3 Cell delin to HEC or PLCP-Change Option 4 to scrambled or not (must match at LIM and connected device.)-Check that Chip Type is set to SUNI QJET-Set Option 10 Reconfigure to yes

-Select M,70,2,3,G[link number],E -Change Option 2 to Enable or Disable -Change Option 3 to scrambled or not (must match at LIM and connected device.)-Change Option 4 to basic or crc

9.0

FOR T1/DS3 SITES ONLY

10.0

FOR E1/E3 SITES ONLY

11.0

12.0

SITE-SPECIFIC CONFIGURATION - ALL SITES

13.0

14. 0

15.0

STATUS & DIAGNOSTICS - ALL SITES

-Select M,69,0,G,22,E,9,B-Exit out to the root menu. -Select M,97,0,E,0,B-Exit out to the root menu. -Select M,97,1,G[link to add],E,1,9,0,B -Exit out to the root menu.-Select M,97,0,E,0,A-Exit out to the root menu.-Select M,69,0,G,22,E,9,A-Exit out to the root menu.-Verify that the added link is being used: - For DSX1, select M,70,3,1 - For the E1 IMA, select M,70,2,1

-Select M,69,0,G,22,E,9,B-Exit out to the root menu. -Select M,97,0,E,0,B-Exit out to the root menu. -Select M,97,1,G[link to remove],E,0,B -Exit out to the root menu.-Select M,97,0,E,0,A-Exit out to the root menu.-Select M,69,0,G,22,E,9,A-Exit out to the root menu.-Verify that the removed link shows no TX/RX: - For DSX1, select M,70,3,1 - For the E1 IMA, select M,70,2,1

-Select M,27-Select Option 4 (Primary Line Ref screen). -Select Option 2 (Reference Select)-Select from Options A - P to specify a link (0 - 15) for system timing.

19.0 Detecting Link Failures19.1 Diagnostic Page - For DS3 site, select M,70,3,0,R - For E3 site, select M,70,2,0,R19.2 Performance Monitoring Page - For DS3 site, select M,70,3,1 - For E3 site, select M,70,2,119.3 Alarms Page - For DS3 site, select M,70,3,2 - For E3 site, select M,70,2,219.4 Alarms Page Detail screen - For DS3 site, select M,70,2,2,G,5,E - For E3 site, select M,70,3,2,G,5,E

19.5 Link Configuration screen - For DS3 site, select M,70,2,3 - For E3 site, select M,70,3,319.6 IMA Link Table - For DS3 or E3 site, select M,97,119.7 IMA Link Table Detail screen - For DS3 or E3 site, select M,97,1,G,5,E

19.8 Configuration/Status screen - For DS3 site, select M,39,1,E - For E3 site, select M,39,2,E19.9 LIM Config/Status screen - For DS3 site, select M,19,4,E - For E3 site, select M,19,3,E19.10 The PLCP Configuration/Status screen - For DS3 or E3 site, select M,39,0,E

Quick Tips

All procedures start from the root menu.M,19,3, indicates keystrokes.The comma indicates the Enter key.The [number] indicates a specific link.To correct a keystroke error, press Esc key. If necessary, go to Step 3 to start over.

3.0

Skip this stepif the unit hasbeen presetfor E1/T1 at the factory.

-Select F,C then arrow to the proper file for site: confT13.4hec for 4 T1 links� confE13.4hec for 4 E1 links-Press Enter to select highlit (“Copy From”) file. -Arrow to config.cfg file, then press Enter.-At confirmation prompt, type Y(es).-At root menu, type W, N, type Y to confirm.

4.0 -Select M,0 (System screen).-Select 0 to specify a contact phone number.-Select 1 to specify a unique node name.-Select 2 to specify node location.-Press X to confirmation prompt, type Y to save.

5.0 -Select M,94,3,E (Tunnel Management Table).-Select Option 09 then enter new IP for the node.-Press X to confirmation prompt, type Y to save.-Exit out to root menu.-Select M,9,6 (Slot-0 Configuration screen)-At the prompt, edit the IP address, then press Enter.-Select 11 (Slot-0 IP Mask prompt)-Type 255.255.255.255 then press Enter.-Type X,X to confirmation prompt, type Y to save.-At root menu, type W, N, type Y to confirm.

6.0 -Select M,23,1,E-Select Option 17 and set to valid (idle). -Select S (Summary), then select M (move). -At the Row to Move prompt, select 0.-Press Enter six times for Source VCI prompt. -Type new VCI number; press enter to complete row. -Type new VPI number; press enter to complete row.-Exit out to root menu, then select M,23,1,E-Select Option 17 then select C (Start Mgmnt VC) -Check that Pk Fd Rate and Pk Bd Rate are at 15.-Exit out to root menu.

8.0 -Log in to PCL as root with password = ADMIN -Within three seconds, press CTRL-C-At the # prompt, type passwd-Type new password at the prompt, then press Enter. -At the confirmation prompt, retype new password.-Type exit to terminate session.

7.0 -Select M,8,2,A[new #], to add new entry number.-Select E[new entry number] to edit the new entry.-At the prompts, define the SNMP Manager: - Enter the Source IP address - For Community Name, type public - For Access type, select Read/write - For Traps, select Send All - For Validity, select valid

18.0 Loopback Tests 18.1 For DS3 loopbacks, select M,19,3,0 - Select B for line loop - Select C for local loop 18.2 For E3 loopbacks, select M,19,4,0 - Select B for line loop - Select C for local loop 18.3 For T1 loopbacks, select M,70,3,G[number],E - Select B for line loop - Select C for diagnostic line loop 18.4 For E1 loopbacks, select M,70,2,G[number],E - Select B for line loop - Select E for diagnostic line loop

17.0 Warm StartUsed with any change in resources, or to put new software or config.cfg into effect, or to resolve a general initialization problem with an IMA LIM. 17.1 At root menu, type W,N 17.2 At the confirmation prompt, type Y(es)

16.0 IMA Group Status 16.1 At root menu, select M,97,0,E�

1.0 -Do not move any component from its position in the chassis as shipped from the manufacturer.-Make cable connections as shown in diagram.

2.0 -Open craft/Telnet session. Use connection settings: 9600, N-8-1, VT100, Raw ASCII-Log in as root with password = MANAGER.

BASIC TROUBLESHOOTING - ALL SITES

START

Log in to PCL from Craft port

?

No

Yes

Check power andcables, settings.

(1.0, 2.0)

Log inOK ?

Swap Chassiswith spare.

Line Errors orAlarms

NoYes

VerifyFacility

DS3 / E3 T1 / E1 IMA

Log inOK ?

Swap PCL andreconfigure. 3.0 - 15.0

Log inOK ?

Yes Log inOK ?

No

Swap PCL andreconfigure. 3.0 - 15.0

SwapIMA LIM

No

Swap DS3or E3 LIM

END

No

Fail/Alarm

?

CallATT

Service

No

Prior toSetup

Log In

ActivateConfig

DefineNode

SetTunnelMgmnt IP

Change TunnelMgmnt VCI/VPI

AddSNMPMgmnt

Change RootPassword

ChangeDS3Settings

ChangeT1Settings

ChangeE3Settings

ChangeE3Settings

Add IMA Link

Remove �IMA Link

ChangeLink used for SysTiming

FacilityOK?

FacilityOK?

Yes Yes

FixFacility

Yes

YesFail/Alarm

?

No

CallATT

Service

No

Log inOK ?

Yes

VerifyFacility

20.1 Troubleshoot- Power- Connections- Login

20.2 Troubleshoot- LIMs- PCL

20.0 Cell Layer Diagnostics 20.1 At root menu, select D,P�