+ All Categories
Home > Documents > Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length....

Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length....

Date post: 24-Apr-2018
Category:
Upload: dinhliem
View: 219 times
Download: 2 times
Share this document with a friend
12
Cable Glands Catalogue ISO 9001
Transcript
Page 1: Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length. part ... protrusion mounting thread cable o/bedding max cable overall max across

Cable Glands Catalogue

ISO 9001

Page 2: Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length. part ... protrusion mounting thread cable o/bedding max cable overall max across

1

LOCKNUT WASHER BODY CLAW SEALS NUT

ACRO

SS C

ORNE

RS

CABL

EOV

ERAL

LM

AX

MOU

NTIN

GTH

READ

THREADLENGTH

Part Number

Mounting Thread Cable Acceptance Details Cable Gland Pack QuantitySize

(mm)Length (mm)

Overall Diameter Across Corners (mm)Min (mm) Max (mm)

NG-12 M12 x 1.5 15 4 7 15 50

NG-16 M16 x 1.5 15 6 10 22 50

NG-20 M20 x 1.5 15 8.5 14 27 25

NG-20-2.5TPS M20 x 1.5 15 2.5mm TPS N/A 27 25

NG-25 M25 x 1.5 15 12.5 18 33 25

NG-32 M32 x 1.5 15 18 25 41 10

NG-40 M40 x 1.5 15 24 32 50 10

NG-50 M50 x 1.5 20 30 41 62 2

NG-63 M63 x 1.5 20 40 51 75 2

Thomas & Betts, a global leader in the design, manufacture and marketing of electrical products and accessories is proud to be the manufacturer of the Nicote range of metal cable glands. This catalogue not only details the full Nicote range, but presents the entire Thomas & Betts range of cable glands from the general purpose NG Nylon range through to 304 Stainless Steel models designed to deliver superior performance in harsh environments.

Thomas & Betts Australasia is proudly committed to delivering innovative solutions to its valued customers through experienced sales and service teams in each state and the National Customer Support Centre. Should you not find what you are looking for in this catalogue or need further information please contact us on 1300 666 595.

NG Cable GlandGeneral Purpose Nylon Cable Glands

Thomas & Betts Nylon Cable Glands are quick & easy to install with a high quality gripping claw/seal arrangement that caters for a wide range of cable sizes per fitting. Each gland has no loose parts and requires no disassembly for cable installation.

Product specifications may change at any time without notice.

ApplicationsIndoor and outdoor use

StandardsAS60529-2004

FunctionProvides seal on cable sheath

Protection ClassIP68, Resistant to salt water, weak alcohol, oil, grease and common solvents

ConstructionBody - UL approved Nylon 66 (Black)Seal - EPDM Rubber

Thread TypeMetric with locknut and IP68 washer

Page 3: Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length. part ... protrusion mounting thread cable o/bedding max cable overall max across

2

The Nicote range of metal cable glands are your guarantee of safety in hazardous locations especially where fire and explosion are an identified risk.

The current Nicote range is quite simply the best available because they do not compromise on safety – and that’s what counts!

Take a look at just some of the features that make Nicote the first choice:

Highly Durable Nickel PlatingNicote glands are coated in a proprietary 2 coat plating process that ensures all metal components will not degrade and potentially let you down over time.

Comprehensive RangeThe greater the range of cable sizes a gland is designed to cover, the higher the risk of seals failing. Nicote contains a comprehensive range with smaller cable acceptance increments that also allows the gland bodies to be smaller and hence easier to use when space is tight.

Full ApprovalsDon’t just take our word for it, independent test bodies have confirmed that the Nicote gland range complies with relevant IEC and Australian standards including approvals for hazardous areas.

Neoprene SealsAll Nicote glands use high quality Neoprene seals that retain their tension and are resistant to Oil, chemicals and flame making them the best choice for hazardous applications.

IP66/68 ProtectionAll Nicote glands classified for indoor or outdoor use are supplied with IP66/68 gaskets for installation on the mounting thread and neoprene seals on the cable sheath. This level of protection means that the glands are protected from the ingress of dust and water. Anything less is unacceptable and compromises safety.

O’Ring SealsAll Nicote glands designed for SWA cable and classified for indoor or outdoor use, feature o’ring seals between the body and sleeve to ensure that water cannot progress along the thread and compromise the seal. Just another safety feature.

Easy to useThe ability to easily produce a tight seal and correct earth everytime is of primary importance. All Nicote glands are designed to be easy to use and to ensure that the installer can see that the correct fitting instructions have been followed. For example, all SWA flameproof glands feature a loose clamping cone so that the installer can see that the armour is fully secured.

When safety matters, there is only one choiceIntroduction

Page 4: Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length. part ... protrusion mounting thread cable o/bedding max cable overall max across

3

MOU

NTIN

G TH

READ

ACRO

SS C

ORNE

RS

CABL

E OV

ERAL

L

MAX

BODY

IP66/68 GASKET NEOPRENE SEAL

SKID WASHER

NUT

PROTRUSIONTHREADLENGTH

Part Number

Mounting Thread Cable Acceptance Details Cable Gland

Size (mm)

Length (mm)

Overall Diameter Across Corners (mm)

Protrusion (mm)Min (mm) Max (mm)

UN12A 1/2” x 26 TPI 10 1.0 6.0 18.3 13

UN16A M16 x 1.5 10 1.0 6.0 20.6 13

UN20A M20 x 1.5 10 6.0 10.6 27.5 14

UN20B M20 x 1.5 10 10.6 15.0 30.9 16

UN25A M25 x 1.5 10 15.0 20.0 33.0 17

UN32A M32 x 1.5 10 20.0 25.0 40.7 18

UN40A M40 x 1.5 16 25.0 30.0 51.1 21

UN40B M40 x 1.5 16 30.0 35.0 55.0 23

UN50A M50 x 1.5 16 35.0 40.0 60.9 23

UN50B M50 x 1.5 16 40.0 45.0 67.0 24

UN63A M63 x 1.5 19 45.0 50.0 78.0 25

UN63B M63 x 1.5 19 50.0 55.0 88.0 32

ApplicationsIndoor and Outdoor use

StandardsAS60529-2004

FunctionProvides Seal on Cable Sheath

Protection ClassIngress of waterIP66/68 (30m)

ConstructionNickel Plated Brass Components

UN Cable GlandGeneral Purpose Cable Gland for Circular Cable

Fitting Instructions1. To comply with IP66/68 approvals, the fibre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus, or use a locknut to secure body.3. Pass the cable through the gland to the required position and tighten gland nut so that the seal grips firmly onto the cable.

Product specifications may change at any time without notice.

Page 5: Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length. part ... protrusion mounting thread cable o/bedding max cable overall max across

4

PROTRUSION

CABL

E OV

ERAL

LM

AX

ACRO

SS C

ORNE

RS

MOU

NTIN

G TH

READ

CABL

EO/

BEDD

ING

MAX

BODYSWA

EXPOSED CLAMP SLEEVE

THREADLENGTH

Part Number

Mounting Thread Cable Acceptance Details Cable Gland SWA Exposed

(mm)

Inner Carton Pack

QuantitySize (mm)

Length (mm)

O/bedding Overall Diameter SWA Dia. (mm)

Across Corners (mm)

Protrusion (mm)Max (mm) Min (mm) Max (mm)

GN164 M16 x 1.5 10.00 7.20 7.40 10.80 0.90 - 1.25 20.5 21.5 8.0 30

GN204 M20 x 1.5 10.00 11.00 10.40 17.00 0.90 - 1.25 25.2 26.3 8.0 20

GN206 M20 x 1.5 10.00 13.75 16.60 20.00 0.90 - 1.25 27.5 26.3 8.0 20

GN254 M25 x 1.5 10.00 16.25 19.60 22.50 0.90 - 1.25 30.3 26.3 8.0 16

GN256 M25 x 1.5 10.00 18.75 22.10 26.00 1.25 - 1.60 33.6 35.7 10.5 8

GN324 M32 x 1.5 10.00 22.75 25.60 30.00 1.25 - 1.60 39.5 38.7 12.0 6

GN326 M32 x 1.5 10.00 26.50 29.60 34.00 1.60 - 2.00 44.5 38.7 12.0 4

GN405 M40 x 1.5 15.00 32.75 33.60 41.50 1.60 - 2.00 54.2 44.6 14.0 6

GN503 M50 x 1.5 15.00 38.50 41.10 49.00 2.00 - 2.50 60.3 51.3 15.5 4

GN505 M50 x 1.5 15.00 44.45 48.60 55.50 2.00 - 2.50 66.7 54.5 15.5 4

GN636 M63 x 1.5 19.00 56.25 55.10 68.25 2.50 - 3.15 82.6 56.0 17.5 2

GN753 2.5” BSP 19.00 60.35 67.85 73.00 2.50 - 3.15 95.3 60.0 21.5 1

GN755 2.5” BSP 19.00 66.70 72.60 79.40 2.50 - 3.15 101.6 60.0 21.5 1

GN Cable GlandGeneral Purpose Cable Gland for Steel Wired Armoured Cable

ApplicationsIndoor use

FunctionProvides Armour Clamp

ConstructionNickel Plated Brass Components

Fitting Instructions1. Screw the gland body into the apparatus.2. Pass the gland sleeve over the cable before commencing to strip the outer sheath of the cable.3. Measure the length of tails required and add about 75mm to the outer sheath and armour to this point.4. Strip the outer sheath.5. Cut the armour wire to the SWA exposed length in the table.6. Pass the armour clamp over the armour.7. Pass the armour cone over the bedding and under the armour wires.8. Pass the bedding through the gland body.9. Engage sleeve thread onto body thread and tighten securely.

Product specifications may change at any time without notice.

Page 6: Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length. part ... protrusion mounting thread cable o/bedding max cable overall max across

5

MOU

NTIN

G TH

READ

CABL

EO/

BEDD

ING

MAX

CABL

E OV

ERAL

LM

AX

PROTRUSION

BODY

IP66/68 GASKETO RINGSEAL CLAMP

SWAEXPOSED

SLEEVE

NEOPRENE SEAL

NUT

ACRO

SS C

ORNE

RS

THREADLENGTH

Part Number

Mounting Thread Cable Acceptance Details Cable Gland SWA Exposed

(mm)

Inner Carton Pack

QuantitySize (mm)

Length (mm)

O/bedding Overall Diameter SWA Dia. (mm)

Across Corners (mm)

Protrusion (mm)Max (mm) Min (mm) Max (mm)

WGN162 M16 x 1.5 14 6.00 8.00 9.60 0.50 - 0.90 24.1 36 8 40

WGN164 M16 x 1.5 14 7.20 9.20 10.80 0.50 - 0.90 24.1 36 8 40

WGN202 M20 x 1.5 14 8.00 10.40 12.00 0.50 - 0.90 25.3 40 9 30

WGN203 M20 x 1.5 14 9.75 11.60 15.50 0.90 - 1.25 27.5 40 9 30

WGN204 M20 x 1.5 14 11.00 15.10 17.00 0.90 - 1.25 27.5 40 9 30

WGN206 M20 x 1.5 14 13.75 16.60 20.00 0.90 - 1.25 33.0 40 9 20

WGN254 M25 x 1.5 14 16.25 19.60 22.50 0.90 - 1.25 36.4 40 9 8

WGN256 M25 x 1.5 14 18.75 22.10 26.00 1.25 - 1.60 40.7 47 11 6

WGN324 M32 x 1.5 14 22.75 25.60 30.00 1.25 - 1.60 49.8 55 12 8

WGN326 M32 x 1.5 14 26.50 29.60 34.00 1.60 - 2.00 49.8 55 12 8

WGN403 M40 x 1.5 15 28.50 33.60 37.00 1.60 - 2.00 60.9 59 13 4

WGN404 M40 x 1.5 15 30.75 36.60 39.50 1.60 - 2.00 60.9 59 13 4

WGN405 M40 x 1.5 15 32.75 39.10 41.50 1.60 - 2.00 60.9 59 13 4

WGN502 M50 x 1.5 15 35.75 41.10 45.00 2.00 - 2.50 76.0 73 14 4

WGN503 M50 x 1.5 15 38.50 44.60 49.00 2.00 - 2.50 76.0 73 14 4

WGN504 M50 x 1.5 15 41.65 48.60 53.50 2.00 - 2.50 86.5 73 14 2

WGN505 M50 x 1.5 15 44.45 53.10 55.50 2.00 - 2.50 86.5 73 14 2

WGN634 M63 x 1.5 19 48.80 55.10 60.35 2.50 - 3.15 101.9 79 15 1

WGN635 M63 x 1.5 19 52.40 59.95 63.50 2.50 - 3.15 101.9 79 15 1

WGN636 M63 x 1.5 19 56.25 63.10 68.25 2.50 - 3.15 101.9 79 15 1

WGN753 2.5” BSP 19 60.35 67.85 73.00 2.50 - 3.15 115.6 93 22 1

WGN754 2.5” BSP 19 63.50 72060 76.20 2.50 - 3.15 115.6 93 22 1

WGN755 2.5” BSP 19 66.70 75.80 79.40 2.50 - 3.15 115.6 93 22 1

WGN10A 3” BSP 19 70.00 79.00 84.00 3.15 124.0 90 22 1

WGN10B 3” BSP 19 76.00 83.60 88.50 3.15 124.0 90 22 1

General Purpose Cable Gland for Steel Wired Armoured Cable

ApplicationsIndoor and outdoor use

FunctionProvides armour clamp, and sealon outer sheath

Protection ClassIngress of waterIP66/68

ConstructionNickel Plated Brass Components

Product specifications may change at any time without notice.

Fitting Instructions1. To comply with IP66/68 approvals, the fibre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus.3. Pass the gland nut, outer seal and gland sleeve over the cable before commencing to strip the outer sheath of the cable.4. Measure the length of tails required and add about 75 mm to the outer sheath and armour to this point.

WGN10A - B Complete with earth fixing lug of 1/2” diameter.

5. Strip the outer sheath.6. Cut the armour wire to SWA exposed length.7. Pass the armour clamp over the armour.8. Pass the body and armour cone over the bedding and under the armour wires.9. Engage sleeve thread onto body thread and tighten securely.10. Slide outer seal and gland nut into position and engage nut thread onto sleeve thread.11. Tighten gland nut securely.

WGN Cable Gland

Page 7: Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length. part ... protrusion mounting thread cable o/bedding max cable overall max across

6

INNER NEOPRENESEAL

SWAEXPOSED

BODY

IP66/68 GASKETO RINGSEAL

CLAMP

CONESLEEVE

NUTOUTER NEOPRENE SEAL

PROTRUSION

ACRO

SS C

ORNE

RS

MOU

NTIN

G TH

READ

CABL

E OV

ERAL

LM

AX

CABL

EO/

BEDD

ING

MAX

THREADLENGTH

Part Number

Mounting Thread Cable Acceptance Details Cable Gland SWA Exposed

(mm)

Inner Carton Pack

QuantitySize (mm)

Length (mm)

Overbedding Overall Diameter SWA Dia. (mm)

Across Corners (mm)

Protrusion (mm)Min (mm) Max (mm) Min (mm) Max (mm)

FLWN202 M20 x 1.5 15.80 6.00 8.00 11.00 13.00 0.50 - 0.90 25 54 12 30

FLWN203 M20 x 1.5 15.80 8.30 9.75 12.50 15.50 0.90 - 1.25 27 54 12 30

FLWN204 M20 x 1.5 15.80 9.35 11.00 15.10 17.00 0.90 - 1.25 27 54 12 30

FLWN205 M20 x 1.5 15.80 10.60 12.50 16.60 20.00 0.90 - 1.25 33 54 12 20

FLWN206 M20 x 1.5 15.80 12.00 13.75 17.00 20.00 0.90 - 1.25 33 54 12 20

FLWN253 M25 x 1.5 19.00 13.35 15.00 19.60 22.50 0.90 - 1.25 36 56 12 14

FLWN254 M25 x 1.5 19.00 14.60 16.25 19.60 22.50 0.90 - 1.25 36 56 12 14

FLWN255 M25 x 1.5 19.00 15.85 17.50 22.10 26.00 1.25 - 1.60 41 56 12 12

FLWN256 M25 x 1.5 19.00 17.10 18.75 23.00 26.00 1.25 - 1.60 41 56 12 12

FLWN323 M32 x 1.5 25.40 18.35 20.75 25.60 30.00 1.25 - 1.60 50 64 13 8

FLWN324 M32 x 1.5 25.40 20.35 22.75 25.60 30.00 1.25 - 1.60 50 64 13 8

FLWN325 M32 x 1.5 25.40 22.35 24.75 29.60 34.00 1.60 - 2.00 50 64 13 8

FLWN326 M32 x 1.5 25.40 24.35 26.50 30.00 34.00 1.60 - 2.00 50 64 13 8

FLWN403 M40 x 1.5 25.40 26.10 28.50 33.60 37.00 1.60 - 2.00 61 72 15 1

FLWN404 M40 x 1.5 25.40 28.10 30.75 36.60 39.50 1.60 - 2.00 61 72 15 1

FLWN405 M40 x 1.5 25.40 30.35 32.75 37.00 41.50 1.60 - 2.00 61 72 15 1

FLWN Cable GlandFlameproof Cable Gland for Steel Wired Armoured Cable

ApplicationsIndoor and Outdoor use in hazardous areas

StandardsIEC 60079 - 0:2004 IEC 60079 - 1:2007 IEC 61241 - 0:2004 IEC 61241 - 1:2004

FunctionProvides O/Bledding Flameproof Seal, ArmourClamp and Seal on Outer Sheath

Protection ClassANZEx 11.2001xIECEx SIM 11.0002XEx d I/IICIngress of waterIP66/68 (30m)

ConstructionNickel Plated Brass Components

Product specifications may change at any time without notice.

9. Pass the armour cone over the bedding and under the armour wires.10. Pass the bedding through the inner seal in the gland body. N.B. Unless this seal provides a push fit on the bedding the next size gland will be required. (The minimum dimension over the bedding is embossed on the sleeve of the gland for reference.) On glands over FLWN405 one or two seals are supplied with each gland, select the most suitable seal.11. Engage sleeve thread onto body thread and tighten securely.12. Slide outer seal and gland nut into position and engage nut thread onto sleeve thread.13. Tighten gland nut securely.

Fitting Instructions1. To comply with IP66/68 approvals, the fibre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus.3. Leave the inner seal in the gland body.4. Pass the gland nut, outer seal and gland sleeve over the cable before commencing to strip the outer sheath of the cable.5. Measure the length of tails required and add about 75 mm to the outer sheath and armour to this point.6. Strip the outer sheath.7. Cut the armour wire to SWA exposed length.8. Pass the armour clamp over the armour.

Page 8: Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length. part ... protrusion mounting thread cable o/bedding max cable overall max across

7

MOU

NTIN

G TH

READ

CABL

EO/

BEDD

ING

MAX

EPOXY

PROTRUSION

CABL

E OV

ERAL

LM

AXAC

ROSS

COR

NERS

CLAMPSWA

EXPOSEDSLEEVE

NUTOUTER NEOPRENE SEALCONE

BODY SLEEVEO RINGSEAL

IP66/68 GASKETBODY

THREADLENGTH

Part Number

Mounting Thread Cable Acceptance Details Cable Gland SWA Exposed

(mm)

Inner Carton Pack

QuantitySize (mm)

Length (mm)

O/bedding Overall Diameter SWA Dia. (mm)

Across Corners (mm)

Protrusion (mm)Max (mm) Min (mm) Max (mm)

FLPW203B M20 x 1.5 15.80 9.75 12.50 15.50 0.90 - 1.25 27 54 11.5 14

FLPW206B M20 x 1.5 15.80 13.75 15.00 20.00 0.90 - 1.25 33 54 11.5 14

FLPW256B M25 x 1.5 19.00 18.75 19.50 26.00 1.25 - 1.60 41 56 11.5 10

FLPW326B M32 x 1.5 25.40 26.50 25.50 34.00 1.60 - 2.00 5 64 13.5 6

FLPW405B M40 x 1.5 25.40 32.75 33.50 41.50 1.60 - 2.00 61 72 15.5 2

FLPW503B M50 x 1.5 28.60 38.50 41.00 49.00 2.00 - 2.50 76 88 17 2

FLPW505B M50 x 1.5 28.60 44.45 48.50 55.50 2.00 - 2.50 87 88 17 2

FLPW635B M63 x 1.5 28.60 52.40 55.00 63.50 2.50 - 3.15 102 96 19 1

FLPW636B M63 x 1.5 28.60 56.25 63.00 68.00 2.50 - 3.15 102 96 19 1

FLPW754B 2.5” BSP 28.60 63.50 67.50 76.00 2.50 - 3.15 116 100 23 1

FLPW755B 2.5” BSP 28.60 66.70 75.50 79.40 2.50 - 3.15 116 100 23 1

Gland Table 1 (mm) Table 2 (mm)

FLPW203B 11.50 13.50

FLPW206B 11.50 13.50

FLPW256B 11.50 13.50

FLPW326B 13.50 15.50

FLPW405B 15.50 17.50

FLPW503B 17.00 17.50

FLPW505B 17.00 19.50

FLPW635B 19.00 21.00

FLPW636B 19.00 21.00

FLPW754B 23.00 25.00

FLPW755B 23.00 25.00

FLPWB Cable GlandBarrier Cable Gland for Steel Wired Armoured Cable

ApplicationsIndoor and Outdoor use in hazardous areas

StandardsIEC 60079 - 0:2004 IEC 60079 - 1:2007 IEC 61241 - 0:2004 IEC 61241 - 1:2004

FunctionProvides Barrier Epoxy Seal to Cable Cores,Armour Clamp, and Seal on Outer Sheath

Protection ClassANZEx 11.2001X IECEx SIM 11.0002X Ex d I//IIC Ingress of waterIP66/68 (30m)

ConstructionNickel Plated Brass Components

Product specifications may change at any time without notice.

Fitting Instructions1. To comply with IP66/68 approvals, the fibre gasket must be installed on the mounting thread.2. Pass Nut, Seal and Sleeve over the outer sheath of cable (Where more than 1 seal is supplied, use the seal with the smallest clearance on the cable).3. Measure the length of cores required and strip the outer sheath and armour wires to the length shown in Table 1.4. Remove the Bedding and any fillers to the length shown in Table 2.5. Slide the clamp over the armour wires and work the Cone over the bedding and under the SWA.6. Locate the Body onto the Cores and hold hard against the face of the Cone. Screw the Sleeve onto the Body and tighten, now tighten the nut onto the sleeve.7. Remove the Body from the assembly.8. Prepare the epoxy putty. This is a 2 part pack and must be mixed in a ratio of 1 to 1 until the colour is even throughout, without any streaks. After mixing it remains pliable for at least 1 hour. (see Useable Life for Mixed Epoxy below)

Note: The Red Epoxy component is affected by storage temperature. Please check to ensure this component is as pliable as the yellow component. It is recommended that the epoxy should be mixed and fitted only with the user wearing the disposable gloves supplied with every gland.

9. Spread the conductors and apply to epoxy to the EXPOSED CENTRE of the conductors. Close the conductors and pack putty into the recess of the cone and down onto the top of the bedding material leaving a shoulder of putty to fill the sleeve cup.

Continue folding putty round the conductors and working it well in between them, joining with that extruded from the core center avoiding any gaps or voids. Cover the conductors from the face of the cone to the length equal at least to the length of the Sleeve.

10. Assemble the Sleeve over the epoxy until it fits into the Cone. Remove any surplus epoxy.11. Reassemble the Body, tighten and allow at least three hours for the epoxy to reach correct hardness.12. Remove the Body, fit to the equipment the reassemble completed fitting.

Useable Life for Mixed Epoxy This will depend upon the bulk mass and temperature. Approximate figures are: 25 grams wt 2 hours @ 25deg. C 25 grams wt 3 hours @ 15deg. C

CureThis will depend upon the bulk mass and temperature. Approximate figures are:25 grams wt 12 hours @ 25deg. C25 grams wt 24 hours @ 15deg. C

Mechanical properties of cured mixTensile strength BS6319 2 days min. 30MPaCompressive strength BS6319 2 days min. 40MPaHardness min 75 shore DSpecific Gravity @ 20 deg. C 1.84 to 1.99

Page 9: Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length. part ... protrusion mounting thread cable o/bedding max cable overall max across

8

CUT

LINE

FOR

MIN

IMUM

CAB

LEDI

AMET

ER

SHRO

UDNU

MBE

RTO

SUI

T GL

AND

FROM

SEL

ECTI

ONCH

ART

MOU

NTIN

G TH

READ

DIAM

ETER

EART

H BO

LTDI

AMET

ER

ACROSS FLATS

MOUNTING THREAD

CUT

LINE

FOR

MIN

IMUM

CAB

LEDI

AMET

ER

SHRO

UDNU

MBE

RTO

SUI

T GL

AND

FROM

SEL

ECTI

ONCH

ART

MOU

NTIN

G TH

READ

DIAM

ETER

EART

H BO

LTDI

AMET

ER

ACROSS FLATS

MOUNTING THREAD

CUT LINE FORMINIMUM CABLE

DIAMETER

SHROUDNUMBER

TO SUIT GLANDFROM SELECTION

CHART

MOUNTING THREAD

DIAMETER

EARTH BOLTDIAMETER

ACROSS FLATS

MOUNTING THREAD

Part Number

Mounting Thread

Earth Bolt Diameter

(mm)

Inner Carton Pack Quantity

E16 M16 6.35 TBA

E20 M20 6.35 200

E25 M25 6.35 100

E32 M32 6.35 50

E40 M40 6.35 50

E50 M50 6.35 25

E63 M63 6.35 25

Part Number

Mounting Thread

Across Flats Hexagon

(mm)

Inner Carton Pack Quantity

L12 1/2” x 26 TPI 16 100

LNB-16 M16 x 1.5 20.7 100

LNB-20 M20 x 1.5 27 100

LNB-25 M25 x 1.5 31.6 100

LNB-32 M32 x 1.5 40 100

LNB-40 M40 x 1.5 48.2 40

LNB-50 M50 x 1.5 57.3 25

LNB-63 M63 x 1.5 82 20

L250 2.5” BSP 94 6

L275 2.75” BSP 102 6

L300 3.0” BSP 116 6

L325 3.25” BSP 116 6

L350 3.5” BSP 124 6

L400 4.0” BSP 140 4

Shroud Size

Cable Gland

UN GN WGN FLWN FLPWB

S0 UN20AUN20B

GN204GN206GN254

WGN162WGN164WGN202

S1 UN25A GN256 WGN203WGN204

FLWN202FLWN203FLWN204

FLPW203B

S2 UN32A WGN206WGN254

FLWN205FLWN206

FLPW206B

S3 GN324GN326

WGN256 FLWN253FLWN254

S4 UN40A FLWN255FLWN256

FLPW256B

S5 UN40BUN50A

GN405 WGN324WGN326

FLWN323FLWN324FLWN325FLWN326

FLPW326B

S6 UN50BUN63A

GN503GN505

WGN403WGN404WGN405

FLWN403FLWN404FLWN405

FLPW405B

S7 UN63B GN636 WGN502WGN503

FLPW503B

Nicote PVC Shroud

Shroud Size

Part Number Black

Part Number Orange

0 S0-BLK S0-ORG

1 S1-BLK S1-ORG

2 S2-BLK S2-ORG

3 S3-BLK S3-ORG

4 S4-BLK S4-ORG

5 S5-BLK S5-ORG

6 S6-BLK S6-ORG

7 S7-BLK S7-ORG

Cable Gland AccessoriesEarth Tags Locknuts

Shrouds

Page 10: Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length. part ... protrusion mounting thread cable o/bedding max cable overall max across

9

As supplied with glands

Part Number

Mounting Thread Size

Cable Gland Carton Pack QuantityUN WGN FLWN FLPWB

UB4P 1/2” UN12A 100

UB8P M16 UN16A WGN162WGN164

100

UB13P M20 UN20A WGN202WGN203WGN204WGN206

FLWN202FLWN203FLWN204FLWN205FLWN206

FLPW203BFLPW206B

100

UB17P M20 UN20B 100

UB22P M25 UN25A WGN254WGN256

FLWN253FLWN254FLWN255FLWN256

FLPW256B 100

UB27P M32 UN32A WGN324WGN326

FLWN323FLWN324FLWN325FLWN326

FLPW326B 100

UB31P M40 UN40AUN40B

WGN403WGN404WGN405

FLWN403FLWN404FLWN405

FLPW405B 100

UB36P M50 UN50A 100

UB41P M50 UN50B WGN502WGN503WGN504WGN505

FLWN502FLWN503FLWN504FLWN505

FLPW503BFLPW505B

100

UB45P M63 UN63AUN63B

WGN634WGN635WGN636

FLWN633FLWN634FLWN635FLWN636

FLPW635BFLPW636B

20

UB117P 2.5” BSP WGN753WGN754WGN755

FLWN753FLWN754FLWN755

FLPW754BFLPW755B

20

UB118P 2.75” BSP 20

UB119B 3” BSP WGN10AWGN10B

20

UB517P 3.5” BSP 20

UB518P 4” BSP 20

Nicote AccessoriesIP66/68 Gasket

Fibre Gasket

Page 11: Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length. part ... protrusion mounting thread cable o/bedding max cable overall max across

10

MOU

NTIN

G TH

READ

ACRO

SS C

ORNE

RS

CABL

E OV

ERAL

L

MAX

BODY

SEAL

SKID WASHER

NUT

PROTRUSIONTHREADLENGTH

Part Number

Mounting Thread Cable Acceptance Details Cable Gland Pack QuantitySize

(mm)Length (mm)

Overall Diameter Across Corners (mm)Min (mm) Max (mm)

SSG-16-8 M16 x 1.5 10 3.5 8.4 22 50

SSG-20-11 M20 x 1.5 10 6.4 11.5 22 25

SSG-20-16 M20 x 1.5 12 11 16.3 27.5 25

SSG-25 M25 x 1.5 12 15 21 32 25

SSG-32 M32 x 1.5 12 19 27.7 40 10

SSG Cable GlandGeneral Purpose Stainless Steel Cable Gland

ApplicationsIndoor and outdoor use in harsh environments

StandardsAS60529-2004

FunctionProvides seal on cable sheath

Protection ClassIP65

ConstructionBody and compression nut304 Stainless Steel

Stainless Steel Cable Glands are high quality glands designed for use in severe environments. Made from 304 grade stainless steel, each gland features a wide cable diameter range and UP65 protection.

Product specifications may change at any time without notice.

Page 12: Cable Glands Catalogue - Plucka · mounting thread cable overall max across corners thread length. part ... protrusion mounting thread cable o/bedding max cable overall max across

For futher information, contact the Thomas & Betts National Support Centre onPhone 1300 666 595 Fax 1300 666 594 Email [email protected] Website www.tnbaust.comThomas & Betts Australasia Pty Ltd Head Office,Unit D3, 3-29, Birnie Avenue, Lidcombe NSW 2141 Australia ABN 62 074 810 898

All technical claims in this document are based upon technical information available at the time of publication. This information may change over time and comparisons may therefore vary.

27 November 2013


Recommended