Cable Glands Catalogue
ISO 9001
1
LOCKNUT WASHER BODY CLAW SEALS NUT
ACRO
SS C
ORNE
RS
CABL
EOV
ERAL
LM
AX
MOU
NTIN
GTH
READ
THREADLENGTH
Part Number
Mounting Thread Cable Acceptance Details Cable Gland Pack QuantitySize
(mm)Length (mm)
Overall Diameter Across Corners (mm)Min (mm) Max (mm)
NG-12 M12 x 1.5 15 4 7 15 50
NG-16 M16 x 1.5 15 6 10 22 50
NG-20 M20 x 1.5 15 8.5 14 27 25
NG-20-2.5TPS M20 x 1.5 15 2.5mm TPS N/A 27 25
NG-25 M25 x 1.5 15 12.5 18 33 25
NG-32 M32 x 1.5 15 18 25 41 10
NG-40 M40 x 1.5 15 24 32 50 10
NG-50 M50 x 1.5 20 30 41 62 2
NG-63 M63 x 1.5 20 40 51 75 2
Thomas & Betts, a global leader in the design, manufacture and marketing of electrical products and accessories is proud to be the manufacturer of the Nicote range of metal cable glands. This catalogue not only details the full Nicote range, but presents the entire Thomas & Betts range of cable glands from the general purpose NG Nylon range through to 304 Stainless Steel models designed to deliver superior performance in harsh environments.
Thomas & Betts Australasia is proudly committed to delivering innovative solutions to its valued customers through experienced sales and service teams in each state and the National Customer Support Centre. Should you not find what you are looking for in this catalogue or need further information please contact us on 1300 666 595.
NG Cable GlandGeneral Purpose Nylon Cable Glands
Thomas & Betts Nylon Cable Glands are quick & easy to install with a high quality gripping claw/seal arrangement that caters for a wide range of cable sizes per fitting. Each gland has no loose parts and requires no disassembly for cable installation.
Product specifications may change at any time without notice.
ApplicationsIndoor and outdoor use
StandardsAS60529-2004
FunctionProvides seal on cable sheath
Protection ClassIP68, Resistant to salt water, weak alcohol, oil, grease and common solvents
ConstructionBody - UL approved Nylon 66 (Black)Seal - EPDM Rubber
Thread TypeMetric with locknut and IP68 washer
2
The Nicote range of metal cable glands are your guarantee of safety in hazardous locations especially where fire and explosion are an identified risk.
The current Nicote range is quite simply the best available because they do not compromise on safety – and that’s what counts!
Take a look at just some of the features that make Nicote the first choice:
Highly Durable Nickel PlatingNicote glands are coated in a proprietary 2 coat plating process that ensures all metal components will not degrade and potentially let you down over time.
Comprehensive RangeThe greater the range of cable sizes a gland is designed to cover, the higher the risk of seals failing. Nicote contains a comprehensive range with smaller cable acceptance increments that also allows the gland bodies to be smaller and hence easier to use when space is tight.
Full ApprovalsDon’t just take our word for it, independent test bodies have confirmed that the Nicote gland range complies with relevant IEC and Australian standards including approvals for hazardous areas.
Neoprene SealsAll Nicote glands use high quality Neoprene seals that retain their tension and are resistant to Oil, chemicals and flame making them the best choice for hazardous applications.
IP66/68 ProtectionAll Nicote glands classified for indoor or outdoor use are supplied with IP66/68 gaskets for installation on the mounting thread and neoprene seals on the cable sheath. This level of protection means that the glands are protected from the ingress of dust and water. Anything less is unacceptable and compromises safety.
O’Ring SealsAll Nicote glands designed for SWA cable and classified for indoor or outdoor use, feature o’ring seals between the body and sleeve to ensure that water cannot progress along the thread and compromise the seal. Just another safety feature.
Easy to useThe ability to easily produce a tight seal and correct earth everytime is of primary importance. All Nicote glands are designed to be easy to use and to ensure that the installer can see that the correct fitting instructions have been followed. For example, all SWA flameproof glands feature a loose clamping cone so that the installer can see that the armour is fully secured.
When safety matters, there is only one choiceIntroduction
3
MOU
NTIN
G TH
READ
ACRO
SS C
ORNE
RS
CABL
E OV
ERAL
L
MAX
BODY
IP66/68 GASKET NEOPRENE SEAL
SKID WASHER
NUT
PROTRUSIONTHREADLENGTH
Part Number
Mounting Thread Cable Acceptance Details Cable Gland
Size (mm)
Length (mm)
Overall Diameter Across Corners (mm)
Protrusion (mm)Min (mm) Max (mm)
UN12A 1/2” x 26 TPI 10 1.0 6.0 18.3 13
UN16A M16 x 1.5 10 1.0 6.0 20.6 13
UN20A M20 x 1.5 10 6.0 10.6 27.5 14
UN20B M20 x 1.5 10 10.6 15.0 30.9 16
UN25A M25 x 1.5 10 15.0 20.0 33.0 17
UN32A M32 x 1.5 10 20.0 25.0 40.7 18
UN40A M40 x 1.5 16 25.0 30.0 51.1 21
UN40B M40 x 1.5 16 30.0 35.0 55.0 23
UN50A M50 x 1.5 16 35.0 40.0 60.9 23
UN50B M50 x 1.5 16 40.0 45.0 67.0 24
UN63A M63 x 1.5 19 45.0 50.0 78.0 25
UN63B M63 x 1.5 19 50.0 55.0 88.0 32
ApplicationsIndoor and Outdoor use
StandardsAS60529-2004
FunctionProvides Seal on Cable Sheath
Protection ClassIngress of waterIP66/68 (30m)
ConstructionNickel Plated Brass Components
UN Cable GlandGeneral Purpose Cable Gland for Circular Cable
Fitting Instructions1. To comply with IP66/68 approvals, the fibre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus, or use a locknut to secure body.3. Pass the cable through the gland to the required position and tighten gland nut so that the seal grips firmly onto the cable.
Product specifications may change at any time without notice.
4
PROTRUSION
CABL
E OV
ERAL
LM
AX
ACRO
SS C
ORNE
RS
MOU
NTIN
G TH
READ
CABL
EO/
BEDD
ING
MAX
BODYSWA
EXPOSED CLAMP SLEEVE
THREADLENGTH
Part Number
Mounting Thread Cable Acceptance Details Cable Gland SWA Exposed
(mm)
Inner Carton Pack
QuantitySize (mm)
Length (mm)
O/bedding Overall Diameter SWA Dia. (mm)
Across Corners (mm)
Protrusion (mm)Max (mm) Min (mm) Max (mm)
GN164 M16 x 1.5 10.00 7.20 7.40 10.80 0.90 - 1.25 20.5 21.5 8.0 30
GN204 M20 x 1.5 10.00 11.00 10.40 17.00 0.90 - 1.25 25.2 26.3 8.0 20
GN206 M20 x 1.5 10.00 13.75 16.60 20.00 0.90 - 1.25 27.5 26.3 8.0 20
GN254 M25 x 1.5 10.00 16.25 19.60 22.50 0.90 - 1.25 30.3 26.3 8.0 16
GN256 M25 x 1.5 10.00 18.75 22.10 26.00 1.25 - 1.60 33.6 35.7 10.5 8
GN324 M32 x 1.5 10.00 22.75 25.60 30.00 1.25 - 1.60 39.5 38.7 12.0 6
GN326 M32 x 1.5 10.00 26.50 29.60 34.00 1.60 - 2.00 44.5 38.7 12.0 4
GN405 M40 x 1.5 15.00 32.75 33.60 41.50 1.60 - 2.00 54.2 44.6 14.0 6
GN503 M50 x 1.5 15.00 38.50 41.10 49.00 2.00 - 2.50 60.3 51.3 15.5 4
GN505 M50 x 1.5 15.00 44.45 48.60 55.50 2.00 - 2.50 66.7 54.5 15.5 4
GN636 M63 x 1.5 19.00 56.25 55.10 68.25 2.50 - 3.15 82.6 56.0 17.5 2
GN753 2.5” BSP 19.00 60.35 67.85 73.00 2.50 - 3.15 95.3 60.0 21.5 1
GN755 2.5” BSP 19.00 66.70 72.60 79.40 2.50 - 3.15 101.6 60.0 21.5 1
GN Cable GlandGeneral Purpose Cable Gland for Steel Wired Armoured Cable
ApplicationsIndoor use
FunctionProvides Armour Clamp
ConstructionNickel Plated Brass Components
Fitting Instructions1. Screw the gland body into the apparatus.2. Pass the gland sleeve over the cable before commencing to strip the outer sheath of the cable.3. Measure the length of tails required and add about 75mm to the outer sheath and armour to this point.4. Strip the outer sheath.5. Cut the armour wire to the SWA exposed length in the table.6. Pass the armour clamp over the armour.7. Pass the armour cone over the bedding and under the armour wires.8. Pass the bedding through the gland body.9. Engage sleeve thread onto body thread and tighten securely.
Product specifications may change at any time without notice.
5
MOU
NTIN
G TH
READ
CABL
EO/
BEDD
ING
MAX
CABL
E OV
ERAL
LM
AX
PROTRUSION
BODY
IP66/68 GASKETO RINGSEAL CLAMP
SWAEXPOSED
SLEEVE
NEOPRENE SEAL
NUT
ACRO
SS C
ORNE
RS
THREADLENGTH
Part Number
Mounting Thread Cable Acceptance Details Cable Gland SWA Exposed
(mm)
Inner Carton Pack
QuantitySize (mm)
Length (mm)
O/bedding Overall Diameter SWA Dia. (mm)
Across Corners (mm)
Protrusion (mm)Max (mm) Min (mm) Max (mm)
WGN162 M16 x 1.5 14 6.00 8.00 9.60 0.50 - 0.90 24.1 36 8 40
WGN164 M16 x 1.5 14 7.20 9.20 10.80 0.50 - 0.90 24.1 36 8 40
WGN202 M20 x 1.5 14 8.00 10.40 12.00 0.50 - 0.90 25.3 40 9 30
WGN203 M20 x 1.5 14 9.75 11.60 15.50 0.90 - 1.25 27.5 40 9 30
WGN204 M20 x 1.5 14 11.00 15.10 17.00 0.90 - 1.25 27.5 40 9 30
WGN206 M20 x 1.5 14 13.75 16.60 20.00 0.90 - 1.25 33.0 40 9 20
WGN254 M25 x 1.5 14 16.25 19.60 22.50 0.90 - 1.25 36.4 40 9 8
WGN256 M25 x 1.5 14 18.75 22.10 26.00 1.25 - 1.60 40.7 47 11 6
WGN324 M32 x 1.5 14 22.75 25.60 30.00 1.25 - 1.60 49.8 55 12 8
WGN326 M32 x 1.5 14 26.50 29.60 34.00 1.60 - 2.00 49.8 55 12 8
WGN403 M40 x 1.5 15 28.50 33.60 37.00 1.60 - 2.00 60.9 59 13 4
WGN404 M40 x 1.5 15 30.75 36.60 39.50 1.60 - 2.00 60.9 59 13 4
WGN405 M40 x 1.5 15 32.75 39.10 41.50 1.60 - 2.00 60.9 59 13 4
WGN502 M50 x 1.5 15 35.75 41.10 45.00 2.00 - 2.50 76.0 73 14 4
WGN503 M50 x 1.5 15 38.50 44.60 49.00 2.00 - 2.50 76.0 73 14 4
WGN504 M50 x 1.5 15 41.65 48.60 53.50 2.00 - 2.50 86.5 73 14 2
WGN505 M50 x 1.5 15 44.45 53.10 55.50 2.00 - 2.50 86.5 73 14 2
WGN634 M63 x 1.5 19 48.80 55.10 60.35 2.50 - 3.15 101.9 79 15 1
WGN635 M63 x 1.5 19 52.40 59.95 63.50 2.50 - 3.15 101.9 79 15 1
WGN636 M63 x 1.5 19 56.25 63.10 68.25 2.50 - 3.15 101.9 79 15 1
WGN753 2.5” BSP 19 60.35 67.85 73.00 2.50 - 3.15 115.6 93 22 1
WGN754 2.5” BSP 19 63.50 72060 76.20 2.50 - 3.15 115.6 93 22 1
WGN755 2.5” BSP 19 66.70 75.80 79.40 2.50 - 3.15 115.6 93 22 1
WGN10A 3” BSP 19 70.00 79.00 84.00 3.15 124.0 90 22 1
WGN10B 3” BSP 19 76.00 83.60 88.50 3.15 124.0 90 22 1
General Purpose Cable Gland for Steel Wired Armoured Cable
ApplicationsIndoor and outdoor use
FunctionProvides armour clamp, and sealon outer sheath
Protection ClassIngress of waterIP66/68
ConstructionNickel Plated Brass Components
Product specifications may change at any time without notice.
Fitting Instructions1. To comply with IP66/68 approvals, the fibre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus.3. Pass the gland nut, outer seal and gland sleeve over the cable before commencing to strip the outer sheath of the cable.4. Measure the length of tails required and add about 75 mm to the outer sheath and armour to this point.
WGN10A - B Complete with earth fixing lug of 1/2” diameter.
5. Strip the outer sheath.6. Cut the armour wire to SWA exposed length.7. Pass the armour clamp over the armour.8. Pass the body and armour cone over the bedding and under the armour wires.9. Engage sleeve thread onto body thread and tighten securely.10. Slide outer seal and gland nut into position and engage nut thread onto sleeve thread.11. Tighten gland nut securely.
WGN Cable Gland
6
INNER NEOPRENESEAL
SWAEXPOSED
BODY
IP66/68 GASKETO RINGSEAL
CLAMP
CONESLEEVE
NUTOUTER NEOPRENE SEAL
PROTRUSION
ACRO
SS C
ORNE
RS
MOU
NTIN
G TH
READ
CABL
E OV
ERAL
LM
AX
CABL
EO/
BEDD
ING
MAX
THREADLENGTH
Part Number
Mounting Thread Cable Acceptance Details Cable Gland SWA Exposed
(mm)
Inner Carton Pack
QuantitySize (mm)
Length (mm)
Overbedding Overall Diameter SWA Dia. (mm)
Across Corners (mm)
Protrusion (mm)Min (mm) Max (mm) Min (mm) Max (mm)
FLWN202 M20 x 1.5 15.80 6.00 8.00 11.00 13.00 0.50 - 0.90 25 54 12 30
FLWN203 M20 x 1.5 15.80 8.30 9.75 12.50 15.50 0.90 - 1.25 27 54 12 30
FLWN204 M20 x 1.5 15.80 9.35 11.00 15.10 17.00 0.90 - 1.25 27 54 12 30
FLWN205 M20 x 1.5 15.80 10.60 12.50 16.60 20.00 0.90 - 1.25 33 54 12 20
FLWN206 M20 x 1.5 15.80 12.00 13.75 17.00 20.00 0.90 - 1.25 33 54 12 20
FLWN253 M25 x 1.5 19.00 13.35 15.00 19.60 22.50 0.90 - 1.25 36 56 12 14
FLWN254 M25 x 1.5 19.00 14.60 16.25 19.60 22.50 0.90 - 1.25 36 56 12 14
FLWN255 M25 x 1.5 19.00 15.85 17.50 22.10 26.00 1.25 - 1.60 41 56 12 12
FLWN256 M25 x 1.5 19.00 17.10 18.75 23.00 26.00 1.25 - 1.60 41 56 12 12
FLWN323 M32 x 1.5 25.40 18.35 20.75 25.60 30.00 1.25 - 1.60 50 64 13 8
FLWN324 M32 x 1.5 25.40 20.35 22.75 25.60 30.00 1.25 - 1.60 50 64 13 8
FLWN325 M32 x 1.5 25.40 22.35 24.75 29.60 34.00 1.60 - 2.00 50 64 13 8
FLWN326 M32 x 1.5 25.40 24.35 26.50 30.00 34.00 1.60 - 2.00 50 64 13 8
FLWN403 M40 x 1.5 25.40 26.10 28.50 33.60 37.00 1.60 - 2.00 61 72 15 1
FLWN404 M40 x 1.5 25.40 28.10 30.75 36.60 39.50 1.60 - 2.00 61 72 15 1
FLWN405 M40 x 1.5 25.40 30.35 32.75 37.00 41.50 1.60 - 2.00 61 72 15 1
FLWN Cable GlandFlameproof Cable Gland for Steel Wired Armoured Cable
ApplicationsIndoor and Outdoor use in hazardous areas
StandardsIEC 60079 - 0:2004 IEC 60079 - 1:2007 IEC 61241 - 0:2004 IEC 61241 - 1:2004
FunctionProvides O/Bledding Flameproof Seal, ArmourClamp and Seal on Outer Sheath
Protection ClassANZEx 11.2001xIECEx SIM 11.0002XEx d I/IICIngress of waterIP66/68 (30m)
ConstructionNickel Plated Brass Components
Product specifications may change at any time without notice.
9. Pass the armour cone over the bedding and under the armour wires.10. Pass the bedding through the inner seal in the gland body. N.B. Unless this seal provides a push fit on the bedding the next size gland will be required. (The minimum dimension over the bedding is embossed on the sleeve of the gland for reference.) On glands over FLWN405 one or two seals are supplied with each gland, select the most suitable seal.11. Engage sleeve thread onto body thread and tighten securely.12. Slide outer seal and gland nut into position and engage nut thread onto sleeve thread.13. Tighten gland nut securely.
Fitting Instructions1. To comply with IP66/68 approvals, the fibre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus.3. Leave the inner seal in the gland body.4. Pass the gland nut, outer seal and gland sleeve over the cable before commencing to strip the outer sheath of the cable.5. Measure the length of tails required and add about 75 mm to the outer sheath and armour to this point.6. Strip the outer sheath.7. Cut the armour wire to SWA exposed length.8. Pass the armour clamp over the armour.
7
MOU
NTIN
G TH
READ
CABL
EO/
BEDD
ING
MAX
EPOXY
PROTRUSION
CABL
E OV
ERAL
LM
AXAC
ROSS
COR
NERS
CLAMPSWA
EXPOSEDSLEEVE
NUTOUTER NEOPRENE SEALCONE
BODY SLEEVEO RINGSEAL
IP66/68 GASKETBODY
THREADLENGTH
Part Number
Mounting Thread Cable Acceptance Details Cable Gland SWA Exposed
(mm)
Inner Carton Pack
QuantitySize (mm)
Length (mm)
O/bedding Overall Diameter SWA Dia. (mm)
Across Corners (mm)
Protrusion (mm)Max (mm) Min (mm) Max (mm)
FLPW203B M20 x 1.5 15.80 9.75 12.50 15.50 0.90 - 1.25 27 54 11.5 14
FLPW206B M20 x 1.5 15.80 13.75 15.00 20.00 0.90 - 1.25 33 54 11.5 14
FLPW256B M25 x 1.5 19.00 18.75 19.50 26.00 1.25 - 1.60 41 56 11.5 10
FLPW326B M32 x 1.5 25.40 26.50 25.50 34.00 1.60 - 2.00 5 64 13.5 6
FLPW405B M40 x 1.5 25.40 32.75 33.50 41.50 1.60 - 2.00 61 72 15.5 2
FLPW503B M50 x 1.5 28.60 38.50 41.00 49.00 2.00 - 2.50 76 88 17 2
FLPW505B M50 x 1.5 28.60 44.45 48.50 55.50 2.00 - 2.50 87 88 17 2
FLPW635B M63 x 1.5 28.60 52.40 55.00 63.50 2.50 - 3.15 102 96 19 1
FLPW636B M63 x 1.5 28.60 56.25 63.00 68.00 2.50 - 3.15 102 96 19 1
FLPW754B 2.5” BSP 28.60 63.50 67.50 76.00 2.50 - 3.15 116 100 23 1
FLPW755B 2.5” BSP 28.60 66.70 75.50 79.40 2.50 - 3.15 116 100 23 1
Gland Table 1 (mm) Table 2 (mm)
FLPW203B 11.50 13.50
FLPW206B 11.50 13.50
FLPW256B 11.50 13.50
FLPW326B 13.50 15.50
FLPW405B 15.50 17.50
FLPW503B 17.00 17.50
FLPW505B 17.00 19.50
FLPW635B 19.00 21.00
FLPW636B 19.00 21.00
FLPW754B 23.00 25.00
FLPW755B 23.00 25.00
FLPWB Cable GlandBarrier Cable Gland for Steel Wired Armoured Cable
ApplicationsIndoor and Outdoor use in hazardous areas
StandardsIEC 60079 - 0:2004 IEC 60079 - 1:2007 IEC 61241 - 0:2004 IEC 61241 - 1:2004
FunctionProvides Barrier Epoxy Seal to Cable Cores,Armour Clamp, and Seal on Outer Sheath
Protection ClassANZEx 11.2001X IECEx SIM 11.0002X Ex d I//IIC Ingress of waterIP66/68 (30m)
ConstructionNickel Plated Brass Components
Product specifications may change at any time without notice.
Fitting Instructions1. To comply with IP66/68 approvals, the fibre gasket must be installed on the mounting thread.2. Pass Nut, Seal and Sleeve over the outer sheath of cable (Where more than 1 seal is supplied, use the seal with the smallest clearance on the cable).3. Measure the length of cores required and strip the outer sheath and armour wires to the length shown in Table 1.4. Remove the Bedding and any fillers to the length shown in Table 2.5. Slide the clamp over the armour wires and work the Cone over the bedding and under the SWA.6. Locate the Body onto the Cores and hold hard against the face of the Cone. Screw the Sleeve onto the Body and tighten, now tighten the nut onto the sleeve.7. Remove the Body from the assembly.8. Prepare the epoxy putty. This is a 2 part pack and must be mixed in a ratio of 1 to 1 until the colour is even throughout, without any streaks. After mixing it remains pliable for at least 1 hour. (see Useable Life for Mixed Epoxy below)
Note: The Red Epoxy component is affected by storage temperature. Please check to ensure this component is as pliable as the yellow component. It is recommended that the epoxy should be mixed and fitted only with the user wearing the disposable gloves supplied with every gland.
9. Spread the conductors and apply to epoxy to the EXPOSED CENTRE of the conductors. Close the conductors and pack putty into the recess of the cone and down onto the top of the bedding material leaving a shoulder of putty to fill the sleeve cup.
Continue folding putty round the conductors and working it well in between them, joining with that extruded from the core center avoiding any gaps or voids. Cover the conductors from the face of the cone to the length equal at least to the length of the Sleeve.
10. Assemble the Sleeve over the epoxy until it fits into the Cone. Remove any surplus epoxy.11. Reassemble the Body, tighten and allow at least three hours for the epoxy to reach correct hardness.12. Remove the Body, fit to the equipment the reassemble completed fitting.
Useable Life for Mixed Epoxy This will depend upon the bulk mass and temperature. Approximate figures are: 25 grams wt 2 hours @ 25deg. C 25 grams wt 3 hours @ 15deg. C
CureThis will depend upon the bulk mass and temperature. Approximate figures are:25 grams wt 12 hours @ 25deg. C25 grams wt 24 hours @ 15deg. C
Mechanical properties of cured mixTensile strength BS6319 2 days min. 30MPaCompressive strength BS6319 2 days min. 40MPaHardness min 75 shore DSpecific Gravity @ 20 deg. C 1.84 to 1.99
8
CUT
LINE
FOR
MIN
IMUM
CAB
LEDI
AMET
ER
SHRO
UDNU
MBE
RTO
SUI
T GL
AND
FROM
SEL
ECTI
ONCH
ART
MOU
NTIN
G TH
READ
DIAM
ETER
EART
H BO
LTDI
AMET
ER
ACROSS FLATS
MOUNTING THREAD
CUT
LINE
FOR
MIN
IMUM
CAB
LEDI
AMET
ER
SHRO
UDNU
MBE
RTO
SUI
T GL
AND
FROM
SEL
ECTI
ONCH
ART
MOU
NTIN
G TH
READ
DIAM
ETER
EART
H BO
LTDI
AMET
ER
ACROSS FLATS
MOUNTING THREAD
CUT LINE FORMINIMUM CABLE
DIAMETER
SHROUDNUMBER
TO SUIT GLANDFROM SELECTION
CHART
MOUNTING THREAD
DIAMETER
EARTH BOLTDIAMETER
ACROSS FLATS
MOUNTING THREAD
Part Number
Mounting Thread
Earth Bolt Diameter
(mm)
Inner Carton Pack Quantity
E16 M16 6.35 TBA
E20 M20 6.35 200
E25 M25 6.35 100
E32 M32 6.35 50
E40 M40 6.35 50
E50 M50 6.35 25
E63 M63 6.35 25
Part Number
Mounting Thread
Across Flats Hexagon
(mm)
Inner Carton Pack Quantity
L12 1/2” x 26 TPI 16 100
LNB-16 M16 x 1.5 20.7 100
LNB-20 M20 x 1.5 27 100
LNB-25 M25 x 1.5 31.6 100
LNB-32 M32 x 1.5 40 100
LNB-40 M40 x 1.5 48.2 40
LNB-50 M50 x 1.5 57.3 25
LNB-63 M63 x 1.5 82 20
L250 2.5” BSP 94 6
L275 2.75” BSP 102 6
L300 3.0” BSP 116 6
L325 3.25” BSP 116 6
L350 3.5” BSP 124 6
L400 4.0” BSP 140 4
Shroud Size
Cable Gland
UN GN WGN FLWN FLPWB
S0 UN20AUN20B
GN204GN206GN254
WGN162WGN164WGN202
S1 UN25A GN256 WGN203WGN204
FLWN202FLWN203FLWN204
FLPW203B
S2 UN32A WGN206WGN254
FLWN205FLWN206
FLPW206B
S3 GN324GN326
WGN256 FLWN253FLWN254
S4 UN40A FLWN255FLWN256
FLPW256B
S5 UN40BUN50A
GN405 WGN324WGN326
FLWN323FLWN324FLWN325FLWN326
FLPW326B
S6 UN50BUN63A
GN503GN505
WGN403WGN404WGN405
FLWN403FLWN404FLWN405
FLPW405B
S7 UN63B GN636 WGN502WGN503
FLPW503B
Nicote PVC Shroud
Shroud Size
Part Number Black
Part Number Orange
0 S0-BLK S0-ORG
1 S1-BLK S1-ORG
2 S2-BLK S2-ORG
3 S3-BLK S3-ORG
4 S4-BLK S4-ORG
5 S5-BLK S5-ORG
6 S6-BLK S6-ORG
7 S7-BLK S7-ORG
Cable Gland AccessoriesEarth Tags Locknuts
Shrouds
9
As supplied with glands
Part Number
Mounting Thread Size
Cable Gland Carton Pack QuantityUN WGN FLWN FLPWB
UB4P 1/2” UN12A 100
UB8P M16 UN16A WGN162WGN164
100
UB13P M20 UN20A WGN202WGN203WGN204WGN206
FLWN202FLWN203FLWN204FLWN205FLWN206
FLPW203BFLPW206B
100
UB17P M20 UN20B 100
UB22P M25 UN25A WGN254WGN256
FLWN253FLWN254FLWN255FLWN256
FLPW256B 100
UB27P M32 UN32A WGN324WGN326
FLWN323FLWN324FLWN325FLWN326
FLPW326B 100
UB31P M40 UN40AUN40B
WGN403WGN404WGN405
FLWN403FLWN404FLWN405
FLPW405B 100
UB36P M50 UN50A 100
UB41P M50 UN50B WGN502WGN503WGN504WGN505
FLWN502FLWN503FLWN504FLWN505
FLPW503BFLPW505B
100
UB45P M63 UN63AUN63B
WGN634WGN635WGN636
FLWN633FLWN634FLWN635FLWN636
FLPW635BFLPW636B
20
UB117P 2.5” BSP WGN753WGN754WGN755
FLWN753FLWN754FLWN755
FLPW754BFLPW755B
20
UB118P 2.75” BSP 20
UB119B 3” BSP WGN10AWGN10B
20
UB517P 3.5” BSP 20
UB518P 4” BSP 20
Nicote AccessoriesIP66/68 Gasket
Fibre Gasket
10
MOU
NTIN
G TH
READ
ACRO
SS C
ORNE
RS
CABL
E OV
ERAL
L
MAX
BODY
SEAL
SKID WASHER
NUT
PROTRUSIONTHREADLENGTH
Part Number
Mounting Thread Cable Acceptance Details Cable Gland Pack QuantitySize
(mm)Length (mm)
Overall Diameter Across Corners (mm)Min (mm) Max (mm)
SSG-16-8 M16 x 1.5 10 3.5 8.4 22 50
SSG-20-11 M20 x 1.5 10 6.4 11.5 22 25
SSG-20-16 M20 x 1.5 12 11 16.3 27.5 25
SSG-25 M25 x 1.5 12 15 21 32 25
SSG-32 M32 x 1.5 12 19 27.7 40 10
SSG Cable GlandGeneral Purpose Stainless Steel Cable Gland
ApplicationsIndoor and outdoor use in harsh environments
StandardsAS60529-2004
FunctionProvides seal on cable sheath
Protection ClassIP65
ConstructionBody and compression nut304 Stainless Steel
Stainless Steel Cable Glands are high quality glands designed for use in severe environments. Made from 304 grade stainless steel, each gland features a wide cable diameter range and UP65 protection.
Product specifications may change at any time without notice.
For futher information, contact the Thomas & Betts National Support Centre onPhone 1300 666 595 Fax 1300 666 594 Email [email protected] Website www.tnbaust.comThomas & Betts Australasia Pty Ltd Head Office,Unit D3, 3-29, Birnie Avenue, Lidcombe NSW 2141 Australia ABN 62 074 810 898
All technical claims in this document are based upon technical information available at the time of publication. This information may change over time and comparisons may therefore vary.
27 November 2013