53
Cable Tray Support Systems & Solutions B.V. Cable Management Solutions B.V. 6 81
Transcript
Page 1: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

Cable Tray

Cable Management Solutions B.V.

E-STRUT BV | Postbus 10025 | 3004 AA Rotterdam | The NetherlandsT: +31 (0)10 522 33 51 | F: +31 (0)10 521 49 [email protected] | www.eurostrut.com

Support Systems & Solutions B.V.Support Systems & Solutions B.V. Cable Management Solutions B.V.

6

81

Page 2: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

33

Cable tray systemsCable tray systems

Cable tray systems

The comprehensive Metsec cable tray rangeconsists of three systems ranging from the lightduty non-return flange cable tray to twosystems with cable-friendly return flange trays,medium duty 25mm deep and heavy duty50mm deep.

The unique perforation pattern allows ease ofattachment of cables with more than adequateventilation. The side walls of the medium andheavy duty ranges are also slotted as standard.

Light duty cable trays are available in widths of50, 75, 100, 150, 225 and 300mm. Medium dutytrays are available in widths of 50, 75, 100,150,225, 300, 450 and 600mm. Heavy duty trays areavailable in widths of 75, 100, 150, 225, 300,450, 600, 750 and 900mm wide.

Each type of tray is a total system with a wideselection of support accessories to providecomprehensive site installation solutions.

Loading graphsSafe working loads are represented graphically as shownand are based on the cable tray being continuous overfour spans or more. Deflection has been limited toSPAN/200 generally, based on the end span condition asthe worst case. Deflection will be less than this on internalspans. However, on wider trays, additional deflection willbe induced locally across the base of the tray, dependingon the width of the tray and the load distribution acrossthe width. This will not be detrimental to the structuralperformance of the tray but may need consideration ifappearance is of prime importance.

Bespoke systemsIn addition to standard cable tray systems, Metsec has theability to manufacture non standard cable tray systems toorder.

Due to sophisticated equipment and software, prototypescan be produced quickly for sample approval.

It is important for customers to issue the complete order atthe outset to allow full use of materials and avoidexpensive waste.

Metsec cable trays are manufactured onsophisticated CNC equipment in a world classmanufacturing cell engaging a high level ofautomation for fast moving items.This allows Metsec to maintain a very high level of on time in full delivery performance.

Comprehensive stocks of cable trays andaccessories in both pre-galvanised and post hotdip galvanised finish are carried at all times toensure timely delivery.

Development and testingMetsec cable tray systems have been fullytested to develop accurate loading graphs.Further verification tests have also been doneunder the requirements of BS EN 61537:2007 –Cable management – cable tray systems andcable ladder systems. These tests includeimpact resistance, marking, connection of re-usable components, safe working load tests,electrical continuity, and performance of steel atextreme temperature ranges.

Metsec cable tray systems have been developedafter significant consultation with major installers.This ensures the systems meet and surpass keyrequirements providing innovative and costeffective solutions in an increasingly demandingmarket

SPAN m

SPAN m

180

140

160

120

100

80

60

40

20

0

140

160

120

100

80

60

40

20

0

300

250

200

150

100

50

0

2.25 2.51.5 1.75 2

SPAN m 1.75 21 1.25 1.5

0.5 0.75 1 1.25 1.5

300/600 wide150/225 wide50/100 wide

450/600 wide225/300 wide75/150 wide

300/450 wide50/225 wide

SA

FE W

OR

KIN

G L

OA

D k

g.p

er m

.S

AFE

WO

RK

ING

LO

AD

kg.

per

m.

SA

FE W

OR

KIN

G L

OA

D k

g.p

er m

.

Return flange - medium duty

SPAN m

SPAN m

180

140

160

120

100

80

60

40

20

0

140

160

120

100

80

60

40

20

0

300

250

200

150

100

50

0

2.25 2.51.5 1.75 2

SPAN m 1.75 21 1.25 1.5

0.5 0.75 1 1.25 1.5

300/600 wide150/225 wide50/100 wide

450/600 wide225/300 wide75/150 wide

300/450 wide50/225 wide

SA

FE W

OR

KIN

G L

OA

D k

g.p

er m

.S

AFE

WO

RK

ING

LO

AD

kg.

per

m.

SA

FE W

OR

KIN

G L

OA

D k

g.p

er m

.

Return flange - heavy duty

SPAN m

SPAN m

180

140

160

120

100

80

60

40

20

0

140

160

120

100

80

60

40

20

0

300

250

200

150

100

50

0

2.25 2.51.5 1.75 2

SPAN m 1.75 21 1.25 1.5

0.5 0.75 1 1.25 1.5

300/600 wide150/225 wide50/100 wide

450/600 wide225/300 wide75/150 wide

300/450 wide50/225 wide

SA

FE W

OR

KIN

G L

OA

D k

g.p

er m

.S

AFE

WO

RK

ING

LO

AD

kg.

per

m.

SA

FE W

OR

KIN

G L

OA

D k

g.p

er m

.

Non-return flange - light duty

82

Page 3: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

33

Cable tray systemsCable tray systems

Cable tray systems

32

The comprehensive Metsec cable tray rangeconsists of three systems ranging from the lightduty non-return flange cable tray to twosystems with cable-friendly return flange trays,medium duty 25mm deep and heavy duty50mm deep.

The unique perforation pattern allows ease ofattachment of cables with more than adequateventilation. The side walls of the medium andheavy duty ranges are also slotted as standard.

Light duty cable trays are available in widths of50, 75, 100, 150, 225 and 300mm. Medium dutytrays are available in widths of 50, 75, 100,150,225, 300, 450 and 600mm. Heavy duty trays areavailable in widths of 75, 100, 150, 225, 300,450, 600, 750 and 900mm wide.

Each type of tray is a total system with a wideselection of support accessories to providecomprehensive site installation solutions.

Loading graphsSafe working loads are represented graphically as shownand are based on the cable tray being continuous overfour spans or more. Deflection has been limited toSPAN/200 generally, based on the end span condition asthe worst case. Deflection will be less than this on internalspans. However, on wider trays, additional deflection willbe induced locally across the base of the tray, dependingon the width of the tray and the load distribution acrossthe width. This will not be detrimental to the structuralperformance of the tray but may need consideration ifappearance is of prime importance.

Bespoke systemsIn addition to standard cable tray systems, Metsec has theability to manufacture non standard cable tray systems toorder.

Due to sophisticated equipment and software, prototypescan be produced quickly for sample approval.

It is important for customers to issue the complete order atthe outset to allow full use of materials and avoidexpensive waste.

Metsec cable trays are manufactured onsophisticated CNC equipment in a world classmanufacturing cell engaging a high level ofautomation for fast moving items.This allows Metsec to maintain a very high level of on time in full delivery performance.

Comprehensive stocks of cable trays andaccessories in both pre-galvanised and post hotdip galvanised finish are carried at all times toensure timely delivery.

Development and testingMetsec cable tray systems have been fullytested to develop accurate loading graphs.Further verification tests have also been doneunder the requirements of BS EN 61537:2007 –Cable management – cable tray systems andcable ladder systems. These tests includeimpact resistance, marking, connection of re-usable components, safe working load tests,electrical continuity, and performance of steel atextreme temperature ranges.

Metsec cable tray systems have been developedafter significant consultation with major installers.This ensures the systems meet and surpass keyrequirements providing innovative and costeffective solutions in an increasingly demandingmarket

SPAN m

SPAN m

180

140

160

120

100

80

60

40

20

0

140

160

120

100

80

60

40

20

0

300

250

200

150

100

50

0

2.25 2.51.5 1.75 2

SPAN m 1.75 21 1.25 1.5

0.5 0.75 1 1.25 1.5

300/600 wide150/225 wide50/100 wide

450/600 wide225/300 wide75/150 wide

300/450 wide50/225 wide

SA

FE W

OR

KIN

G L

OA

D k

g.p

er m

.S

AFE

WO

RK

ING

LO

AD

kg.

per

m.

SA

FE W

OR

KIN

G L

OA

D k

g.p

er m

.

Return flange - medium duty

SPAN m

SPAN m

180

140

160

120

100

80

60

40

20

0

140

160

120

100

80

60

40

20

0

300

250

200

150

100

50

0

2.25 2.51.5 1.75 2

SPAN m 1.75 21 1.25 1.5

0.5 0.75 1 1.25 1.5

300/600 wide150/225 wide50/100 wide

450/600 wide225/300 wide75/150 wide

300/450 wide50/225 wide

SA

FE W

OR

KIN

G L

OA

D k

g.p

er m

.S

AFE

WO

RK

ING

LO

AD

kg.

per

m.

SA

FE W

OR

KIN

G L

OA

D k

g.p

er m

.

Return flange - heavy duty

SPAN m

SPAN m

180

140

160

120

100

80

60

40

20

0

140

160

120

100

80

60

40

20

0

300

250

200

150

100

50

0

2.25 2.51.5 1.75 2

SPAN m 1.75 21 1.25 1.5

0.5 0.75 1 1.25 1.5

300/600 wide150/225 wide50/100 wide

450/600 wide225/300 wide75/150 wide

300/450 wide50/225 wide

SA

FE W

OR

KIN

G L

OA

D k

g.p

er m

.S

AFE

WO

RK

ING

LO

AD

kg.

per

m.

SA

FE W

OR

KIN

G L

OA

D k

g.p

er m

.

Non-return flange - light duty

83

Page 4: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

35

Cable tray systemsSystem configuration and supportMetsec cable trays are designed as a completesystem with simple accessories. Integralconnectors are included for bends tees etc. forall cable tray ranges.

When installing Metsec cable trays care shouldbe taken to ensure accessories

Technical construction detailsMedium and heavy duty cable traysystems have cable-friendly returnflanges that are also slotted for allwidths as standard. The uniqueperforation pattern in the base of thecable trays allows ease of attachmentfor cables with more than adequateventilation. All Metsec cable trayranges have the same plan footprintthat facilitates the set out of cable runsprior to finalisation of design.

DB illus here

Widths 50 to 225

12

Width 300

18

Widths 50 to 600

25

Widths 75 to 900

50

Widths 50 to 225

12

Width 300

18

Widths 50 to 600

25

Widths 75 to 900

50

Widths 50 to 225

12

Width 300

18

Widths 50 to 600

25

Widths 75 to 900

50

39.0

8.0

15.0

15.039.0

8.0

8.0

Equal tee

Straight length

Internal riser

90° flat bend

Straight reducer

90° flat bend

45° flat bend

Straight length

Straight length

Straight length

Straight length

External riser

Crossover

Cable tray systemsCable tray systems

Materials and finishesMaterials and finishes available aremild steel pre-galvanised as standard,mild steel hot dip galvanised aftermanfacture and stainless steel grade316L to order.

Mild steel pre galvanised:manufactured from steel complyingwith BS EN 10346 2009.Mild steel hot dip galvanised:manufactured from steel complyingwith BS EN 10130:2006 and hot dipgalvanised after manufacture to BS EN 1461:2009.

Stainless steel: manufactured fromstainless steel grade 316L complyingwith BS EN 10088-2:2005.

Light duty

Medium duty

Heavy duty

(e.g. bends, tees, crossovers etc.) have adequatesupport with additional supports for largercomponents. Light duty cable tray straightshave one end swaged for easy connection to thenext tray. When light duty straight trays are cutto smaller lengths on site connection to the nexttray requires a fishplate.

84

Page 5: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

Cable tray systems

34

System configuration and supportMetsec cable trays are designed as a completesystem with simple accessories. Integralconnectors are included for bends tees etc. forall cable tray ranges.

When installing Metsec cable trays care shouldbe taken to ensure accessories

Technical construction detailsMedium and heavy duty cable traysystems have cable-friendly returnflanges that are also slotted for allwidths as standard. The uniqueperforation pattern in the base of thecable trays allows ease of attachmentfor cables with more than adequateventilation. All Metsec cable trayranges have the same plan footprintthat facilitates the set out of cable runsprior to finalisation of design.

DB illus here

Widths 50 to 225

12

Width 300

18

Widths 50 to 600

25

Widths 75 to 900

50

Widths 50 to 225

12

Width 300

18

Widths 50 to 600

25

Widths 75 to 900

50

Widths 50 to 225

12

Width 300

18

Widths 50 to 600

25

Widths 75 to 900

50

39.0

8.0

15.0

15.039.0

8.0

8.0

Equal tee

Straight length

Internal riser

90° flat bend

Straight reducer

90° flat bend

45° flat bend

Straight length

Straight length

Straight length

Straight length

External riser

Crossover

Cable tray systemsCable tray systems

Materials and finishesMaterials and finishes available aremild steel pre-galvanised as standard,mild steel hot dip galvanised aftermanfacture and stainless steel grade316L to order.

Mild steel pre galvanised:manufactured from steel complyingwith BS EN 10346 2009.Mild steel hot dip galvanised:manufactured from steel complyingwith BS EN 10130:2006 and hot dipgalvanised after manufacture to BS EN 1461:2009.

Stainless steel: manufactured fromstainless steel grade 316L complyingwith BS EN 10088-2:2005.

Light duty

Medium duty

Heavy duty

(e.g. bends, tees, crossovers etc.) have adequatesupport with additional supports for largercomponents. Light duty cable tray straightshave one end swaged for easy connection to thenext tray. When light duty straight trays are cutto smaller lengths on site connection to the nexttray requires a fishplate.

85

Page 6: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

37

StandardsCable tray systemsCable tray systems

Metsec Cable Tray Systems generally conform to BS EN 61537:2007 Cable management - cable traysystems and cable ladder systems.

Information relating to compliance is detailed/highlightedwithin the following sections of the standard:

6 Classification6.1 According to material6.1.1 Metsec cable tray systems are metallic systemcomponents

6.2 According to resistance to flame propagation6.2.2 Metsec cable tray systems are non-flamepropagating system components

6.6 According to temperature6.6.1 Minimum temperature for the system components isgiven in Table 2.6.6.2 Maximum temperature for the system components isgiven in Table 3.

6.7 According to the free base area of the cable tray lengthas given in Table 4.

6.3 According to electrical continuity characteristics6.3.2 Metsec cable tray systems have electrical continuitycharacteristics

6.4 According to electrical conductivity6.4.1 Metsec cable tray systems are electrically conductivesystem components

6.5 According to resistance against corrosion6.5.2 Metsec cable tray systems are made of steel withmetallic finishes or stainless steel

(Resistance to corrosion is classified according to Table 1and follow the relevant specification in Table 8, withcompliance according to Table 7.)

Table 1 - classification for resistance against corrosionClass Reference - material and finish

0 (a) None

1 Electroplated to a minimum thickness of 5 µm

2 Electroplated to a minimum thickness of 12 µm

3 Pre - galvanised to grade 275 to EN 10327 and EN 10326

4 Pre - galvanised to grade 350 to EN 10346: 2009

5 Post - galvanised to a zinc mean coating thickness (minimum) of 45 µm according to ISO 1461 for zinc thickness only

6 Post - galvanised to a zinc mean coating thickness (minimum) of 55 µm according to ISO 1461 for zinc thickness only

7 Post - galvanised to a zinc mean coating thickness (minimum) of 70 µm according to ISO 1461 for zinc thickness only

8 Post - galvanised to a zinc mean coating thickness (minimum) of 85 µm according to ISO 1461 for zinc thickness only

9A Stainless steel manufactured to ASTM: A 240/A 240M - 95a designation S30400 or EN 10088 grade 1 - 4301 without a post treatment (b)

9B Stainless steel manufactured to ASTM: A 240/A 240M - 95a designation S31603 or EN 10088 grade 1 - 4404 without a post treatment (b)

9C Stainless steel manufactured to ASTM: A 240/A 240M - 95a designation S30400 or EN 10088 grade 1 - 4301 with a post treatment (b)

9D Stainless steel manufactured to ASTM: A 240/A 240M - 95a designation S31603 or EN 10088 grade 1 - 4404 with a post treatment (b)

(a) For materials which have no declared corrosion resistance classification

(b) The post-treatment process is used to improve the protection against crevice crack corrosion and the contamination by other steels

Table 7 - System component compliance and classification forresistance against corrosionSystem component Classification Compliance Subclause forMaterial and finishes according to compliance check

Non - metallic 6.5.1 Declaration 14.2.1

Reference - 6.5.2 Table 1 Declaration 14.2.2zinc coating classes 1 to 8 or measurementas in Table 1.

Non - referenced zinc 6.5.2 Table 1 By neutral salt 14.2.3coating classes 1 to 8 spray test NSS

Reference - stainless 6.5.2 Table 1 Declaration 14.2.2steel as in Table 1. Class 9A to 9D

Non-referenced Not classified Declaration Nonestainless steel

Other metallic coatings 6.5.2 Table 1 By neutral salt 14.2.3Column 1 classes spray test NSS1 to 8

Aluminium alloys or other 6.5.3 Under Under 14.2.4metals consideration consideration

Organic coatings 6.5.4 Under Under 14.2.5consideration consideration

Table 8 - Zinc coating thickness of referencematerialsClass Minimum Minimum coating Mean coating

Thickness thickness as given in thickness (minimum)BSEN 10346:2009 to ISO 1461

µm µm µm

0 (a) - - -1 5 - -2 12 - -3 - 15 -4 - 19 -5 - - 456 - - 557 - - 708 - - 85

(a) As declared by the manufacturer or responsible vendor

Table 2 - Minimum

temperature classificationMinimum transport, storageinstallation and applicationtemperature °C

+5- 5- 15- 20- 40- 50

Table 4 - Perforation base classificationClassification Perforation in the base area

A Up to 2%B Over 2% and up to 15%C Over 15% and up to 30%D More than 30%

Note: Classification D relates to IEC 60364 - 5 - 52 Subclause A.52.6.2second paragraph

Table 3 - Maximum

temperature classificationMaximum transport, storageinstallation and applicationtemperature °C

+40+60+90+105+120+150

6.9 According to impact resistance6.9.4 System component offering impact resistance up to20 J (as verified by testing in accordance with 10.9 Test forimpact resistance.)

7 Marking and documentation7.1 Each system component is marked by a label. Labelsused fully comply with the rubbing test. Boxed items arelabelled on the packaging

8 Dimensions

Key cross sectional dimensions for straight cable trays

Part No. External Internal External Internal X-sectionaldepth mm depth mm width mm width mm area mm2

(Internal)

CTSL12/0050# 12 11.1 50 48.2 535CTSL12/0075# 12 11.1 75 73.2 813CTSL12/0100# 12 11.1 100 98.2 1090CTSL12/0150# 12 11.1 150 148.2 1645CTSL12/0225# 12 11.1 225 223.2 2478CTSL18/0300# 18 16.8 300 297.6 5000CTSL25/0050# 25 24.3 50 48.6 1181CTSL25/0075# 25 24.3 75 73.6 1788CTSL25/0100# 25 24.3 100 98.6 2396CTSL25/0150# 25 24.1 150 148.2 3572CTSL25/0225# 25 24.1 225 223.2 5379CTSL25/0300# 25 24.0 300 298.0 7152CTSL25/0450# 25 23.8 450 447.6 10653CTSL25/0600# 25 23.8 600 597.6 14223CTSL50/0075# 50 49.2 75 73.4 3611CTSL50/0100# 50 49.2 100 98.4 4841CTSL50/0150# 50 49.1 150 148.2 7277CTSL50/0225# 50 48.8 225 222.6 10863CTSL50/0300# 50 48.8 300 297.6 14523CTSL50/0450# 50 48.5 450 447.0 21680CTSL50/0600# 50 48.5 600 597.0 28955CTSL50/0750# 50 48.0 750 746.0 35808CTSL50/0900# 50 48.0 900 896.0 43008

Minimum internal radius of fittingsMinimal internal radius of fittings available for theaccommodation of cables is 125mm.

9 Construction9.1 Surfaces of system components which are likely tocome into contact with cables during installation areinspected to ensure they shall not cause damage to thecables when installed correctly.9.2 As with all metallic system components, care should beexercised that handling is in accordance with the relativeCOSHH regulations and gloves should be worn.9.3 Screwed connections have been designed to withstandthe mechanical stresses occurring during installations andnormal use and will not cause damage to cables whencorrectly inserted. Screwed connections are in general ISOmetric threads fully compliant to tests in accordance with9.3.1 and 9.3.2 of the standard. Metsec cable tray systemsare usually assembled using M6 roofing bolts particularlyfor couplers, fishplates and connection to supportingframework. These bolts should be tightened to a torque of12N/m.

10 Mechanical propertiesCable tray lengths have been tested generally inaccordance with the standard under 10.2 and 10.3 forverification of the loading graphs. It should be noted thatindependent testing has been carried out to verify thestructural performance of the cable trays at the minimumand maximum temperature classifications for testconditions under 10.2.2.

All accessories eg bends, tees etc should be directlysupported by a suitable support device or devices atappropriate positions.

86

Page 7: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

36

StandardsCable tray systemsCable tray systems

Metsec Cable Tray Systems generally conform to BS EN 61537:2007 Cable management - cable traysystems and cable ladder systems.

Information relating to compliance is detailed/highlightedwithin the following sections of the standard:

6 Classification6.1 According to material6.1.1 Metsec cable tray systems are metallic systemcomponents

6.2 According to resistance to flame propagation6.2.2 Metsec cable tray systems are non-flamepropagating system components

6.6 According to temperature6.6.1 Minimum temperature for the system components isgiven in Table 2.6.6.2 Maximum temperature for the system components isgiven in Table 3.

6.7 According to the free base area of the cable tray lengthas given in Table 4.

6.3 According to electrical continuity characteristics6.3.2 Metsec cable tray systems have electrical continuitycharacteristics

6.4 According to electrical conductivity6.4.1 Metsec cable tray systems are electrically conductivesystem components

6.5 According to resistance against corrosion6.5.2 Metsec cable tray systems are made of steel withmetallic finishes or stainless steel

(Resistance to corrosion is classified according to Table 1and follow the relevant specification in Table 8, withcompliance according to Table 7.)

Table 1 - classification for resistance against corrosionClass Reference - material and finish

0 (a) None

1 Electroplated to a minimum thickness of 5 µm

2 Electroplated to a minimum thickness of 12 µm

3 Pre - galvanised to grade 275 to EN 10327 and EN 10326

4 Pre - galvanised to grade 350 to EN 10346: 2009

5 Post - galvanised to a zinc mean coating thickness (minimum) of 45 µm according to ISO 1461 for zinc thickness only

6 Post - galvanised to a zinc mean coating thickness (minimum) of 55 µm according to ISO 1461 for zinc thickness only

7 Post - galvanised to a zinc mean coating thickness (minimum) of 70 µm according to ISO 1461 for zinc thickness only

8 Post - galvanised to a zinc mean coating thickness (minimum) of 85 µm according to ISO 1461 for zinc thickness only

9A Stainless steel manufactured to ASTM: A 240/A 240M - 95a designation S30400 or EN 10088 grade 1 - 4301 without a post treatment (b)

9B Stainless steel manufactured to ASTM: A 240/A 240M - 95a designation S31603 or EN 10088 grade 1 - 4404 without a post treatment (b)

9C Stainless steel manufactured to ASTM: A 240/A 240M - 95a designation S30400 or EN 10088 grade 1 - 4301 with a post treatment (b)

9D Stainless steel manufactured to ASTM: A 240/A 240M - 95a designation S31603 or EN 10088 grade 1 - 4404 with a post treatment (b)

(a) For materials which have no declared corrosion resistance classification

(b) The post-treatment process is used to improve the protection against crevice crack corrosion and the contamination by other steels

Table 7 - System component compliance and classification forresistance against corrosionSystem component Classification Compliance Subclause forMaterial and finishes according to compliance check

Non - metallic 6.5.1 Declaration 14.2.1

Reference - 6.5.2 Table 1 Declaration 14.2.2zinc coating classes 1 to 8 or measurementas in Table 1.

Non - referenced zinc 6.5.2 Table 1 By neutral salt 14.2.3coating classes 1 to 8 spray test NSS

Reference - stainless 6.5.2 Table 1 Declaration 14.2.2steel as in Table 1. Class 9A to 9D

Non-referenced Not classified Declaration Nonestainless steel

Other metallic coatings 6.5.2 Table 1 By neutral salt 14.2.3Column 1 classes spray test NSS1 to 8

Aluminium alloys or other 6.5.3 Under Under 14.2.4metals consideration consideration

Organic coatings 6.5.4 Under Under 14.2.5consideration consideration

Table 8 - Zinc coating thickness of referencematerialsClass Minimum Minimum coating Mean coating

Thickness thickness as given in thickness (minimum)BSEN 10346:2009 to ISO 1461

µm µm µm

0 (a) - - -1 5 - -2 12 - -3 - 15 -4 - 19 -5 - - 456 - - 557 - - 708 - - 85

(a) As declared by the manufacturer or responsible vendor

Table 2 - Minimum

temperature classificationMinimum transport, storageinstallation and applicationtemperature °C

+5- 5- 15- 20- 40- 50

Table 4 - Perforation base classificationClassification Perforation in the base area

A Up to 2%B Over 2% and up to 15%C Over 15% and up to 30%D More than 30%

Note: Classification D relates to IEC 60364 - 5 - 52 Subclause A.52.6.2second paragraph

Table 3 - Maximum

temperature classificationMaximum transport, storageinstallation and applicationtemperature °C

+40+60+90+105+120+150

6.9 According to impact resistance6.9.4 System component offering impact resistance up to20 J (as verified by testing in accordance with 10.9 Test forimpact resistance.)

7 Marking and documentation7.1 Each system component is marked by a label. Labelsused fully comply with the rubbing test. Boxed items arelabelled on the packaging

8 Dimensions

Key cross sectional dimensions for straight cable trays

Part No. External Internal External Internal X-sectionaldepth mm depth mm width mm width mm area mm2

(Internal)

CTSL12/0050# 12 11.1 50 48.2 535CTSL12/0075# 12 11.1 75 73.2 813CTSL12/0100# 12 11.1 100 98.2 1090CTSL12/0150# 12 11.1 150 148.2 1645CTSL12/0225# 12 11.1 225 223.2 2478CTSL18/0300# 18 16.8 300 297.6 5000CTSL25/0050# 25 24.3 50 48.6 1181CTSL25/0075# 25 24.3 75 73.6 1788CTSL25/0100# 25 24.3 100 98.6 2396CTSL25/0150# 25 24.1 150 148.2 3572CTSL25/0225# 25 24.1 225 223.2 5379CTSL25/0300# 25 24.0 300 298.0 7152CTSL25/0450# 25 23.8 450 447.6 10653CTSL25/0600# 25 23.8 600 597.6 14223CTSL50/0075# 50 49.2 75 73.4 3611CTSL50/0100# 50 49.2 100 98.4 4841CTSL50/0150# 50 49.1 150 148.2 7277CTSL50/0225# 50 48.8 225 222.6 10863CTSL50/0300# 50 48.8 300 297.6 14523CTSL50/0450# 50 48.5 450 447.0 21680CTSL50/0600# 50 48.5 600 597.0 28955CTSL50/0750# 50 48.0 750 746.0 35808CTSL50/0900# 50 48.0 900 896.0 43008

Minimum internal radius of fittingsMinimal internal radius of fittings available for theaccommodation of cables is 125mm.

9 Construction9.1 Surfaces of system components which are likely tocome into contact with cables during installation areinspected to ensure they shall not cause damage to thecables when installed correctly.9.2 As with all metallic system components, care should beexercised that handling is in accordance with the relativeCOSHH regulations and gloves should be worn.9.3 Screwed connections have been designed to withstandthe mechanical stresses occurring during installations andnormal use and will not cause damage to cables whencorrectly inserted. Screwed connections are in general ISOmetric threads fully compliant to tests in accordance with9.3.1 and 9.3.2 of the standard. Metsec cable tray systemsare usually assembled using M6 roofing bolts particularlyfor couplers, fishplates and connection to supportingframework. These bolts should be tightened to a torque of12N/m.

10 Mechanical propertiesCable tray lengths have been tested generally inaccordance with the standard under 10.2 and 10.3 forverification of the loading graphs. It should be noted thatindependent testing has been carried out to verify thestructural performance of the cable trays at the minimumand maximum temperature classifications for testconditions under 10.2.2.

All accessories eg bends, tees etc should be directlysupported by a suitable support device or devices atappropriate positions.

87

Page 8: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

39

Cable tray systemsProduct footprint

Length 1 = Width + radius

Radius

Radius

Radius

100

Width

Width 1 Width 2

Radius250mm

Radius

Length 2 = width + 2 x radius

Width Radius

Width

Radius

Width

Radius

Length 1 = width 1 + radius

Width 2

Radius

250m

m

Radius

Radius

Radius

Length 2 = width 2 + 2 x radius

Length = width + 2 x radius

Width

Length = width + 2 x radius

Radius

Width

Width 1

Radius

Radius

Radius

100

width 2Width 1

Length = width+ radius

Length = width + radius

Radius

RadiusRadius

Radius

90º flat bend Crossover

Equal tee Unequal tee

90º riser Straight or right / left hand reducer

Straight length

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Light duty Medium duty Heavy dutymm

50 CTSL12/0050PG3 CTSL25/0050PG3 N/A

75 CTSL12/0075PG3 CTSL25/0075PG3 CTSL50/0075PG3

100 CTSL12/0100PG3 CTSL25/0100PG3 CTSL50/0100PG3

150 CTSL12/0150PG3 CTSL25/0150PG3 CTSL50/0150PG3

225 CTSL12/0225PG3 CTSL25/0225PG3 CTSL50/0225PG3

300 CTSL18/0300PG3 CTSL25/0300PG3 CTSL50/0300PG3

450 N/A CTSL25/0450PG3 CTSL50/0450PG3

600 N/A CTSL25/0600PG3 CTSL50/0600PG3

750 N/A N/A CTSL50/0750PG3

900 N/A N/A CTSL50/0900PG3

Medium duty straight couplers

Only required for straight tray to straight tray connection – medium duty rangeFinish: post galvanised = HDG, stainless steel grade 316 = SS

Sold in pairs (fasteners excluded)

CTSC25HDGPR

Not available in pre galvanised

Medium duty wrap over couplers

Only required for straight tray to straight tray connection – medium duty rangeFinish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Sold in pairs (fasteners excluded)

CTC25PGPR

Heavy duty straight couplers

Only required for straight tray to straight tray connection – heavy duty rangeFinish: post galvanised = HDG, stainless steel grade 316 = SS

Sold in pairs (fasteners excluded)

CTSC50HDGPR

Not available in pre galvanised

Heavy duty wrap over couplers

Only required for straight tray to straight tray connection – heavy duty rangeFinish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Sold in pairs (fasteners excluded)

CTC50PGPR

Cable tray systemsCable tray systems

Footprints are identical for all ranges

Cable tray — accessory foot printStandard radius is 125mm

88

Page 9: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

Cable tray systems

38

Product footprint

Length 1 = Width + radius

Radius

Radius

Radius

100

Width

Width 1 Width 2

Radius250mm

Radius

Length 2 = width + 2 x radius

Width Radius

Width

Radius

Width

Radius

Length 1 = width 1 + radius

Width 2

Radius

250m

m

Radius

Radius

Radius

Length 2 = width 2 + 2 x radius

Length = width + 2 x radius

Width

Length = width + 2 x radius

Radius

Width

Width 1

Radius

Radius

Radius

100

width 2Width 1

Length = width+ radius

Length = width + radius

Radius

RadiusRadius

Radius

90º flat bend Crossover

Equal tee Unequal tee

90º riser Straight or right / left hand reducer

Straight length

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Light duty Medium duty Heavy dutymm

50 CTSL12/0050PG3 CTSL25/0050PG3 N/A

75 CTSL12/0075PG3 CTSL25/0075PG3 CTSL50/0075PG3

100 CTSL12/0100PG3 CTSL25/0100PG3 CTSL50/0100PG3

150 CTSL12/0150PG3 CTSL25/0150PG3 CTSL50/0150PG3

225 CTSL12/0225PG3 CTSL25/0225PG3 CTSL50/0225PG3

300 CTSL18/0300PG3 CTSL25/0300PG3 CTSL50/0300PG3

450 N/A CTSL25/0450PG3 CTSL50/0450PG3

600 N/A CTSL25/0600PG3 CTSL50/0600PG3

750 N/A N/A CTSL50/0750PG3

900 N/A N/A CTSL50/0900PG3

Medium duty straight couplers

Only required for straight tray to straight tray connection – medium duty rangeFinish: post galvanised = HDG, stainless steel grade 316 = SS

Sold in pairs (fasteners excluded)

CTSC25HDGPR

Not available in pre galvanised

Medium duty wrap over couplers

Only required for straight tray to straight tray connection – medium duty rangeFinish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Sold in pairs (fasteners excluded)

CTC25PGPR

Heavy duty straight couplers

Only required for straight tray to straight tray connection – heavy duty rangeFinish: post galvanised = HDG, stainless steel grade 316 = SS

Sold in pairs (fasteners excluded)

CTSC50HDGPR

Not available in pre galvanised

Heavy duty wrap over couplers

Only required for straight tray to straight tray connection – heavy duty rangeFinish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Sold in pairs (fasteners excluded)

CTC50PGPR

Cable tray systemsCable tray systems

Footprints are identical for all ranges

Cable tray — accessory foot printStandard radius is 125mm

89

Page 10: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

41

Cable tray systems90º flat bends

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Light duty Medium duty Heavy dutymm

50 CTFB12/0050PG90 CTFB25/0050PG90 N/A

75 CTFB12/0075PG90 CTFB25/0075PG90 CTFB50/0075PG90

100 CTFB12/0100PG90 CTFB25/0100PG90 CTFB50/0100PG90

150 CTFB12/0150PG90 CTFB25/0150PG90 CTFB50/0150PG90

225 CTFB12/0225PG90 CTFB25/0225PG90 CTFB50/0225PG90

300 CTFB18/0300PG90 CTFB25/0300PG90 CTFB50/0300PG90

450 N/A CTFB25/0450PG90 CTFB50/0450PG90

600 N/A CTFB25/0600PG90 CTFB50/0600PG90

750 N/A N/A CTFB50/0750PG90

900 N/A N/A CTFB50/0900PG90

45º flat bends

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Light duty Medium duty Heavy dutymm

50 CTFB12/0050PG45 CTFB25/0050PG45 N/A

75 CTFB12/0075PG45 CTFB25/0075PG45 CTFB50/0075PG45

100 CTFB12/0100PG45 CTFB25/0100PG45 CTFB50/0100PG45

150 CTFB12/0150PG45 CTFB25/0150PG45 CTFB50/0150PG45

225 CTFB12/0225PG45 CTFB25/0225PG45 CTFB50/0225PG45

300 CTFB18/0300PG45 CTFB25/0300PG45 CTFB50/0300PG45

450 N/A CTFB25/0450PG45 CTFB50/0450PG45

600 N/A CTFB25/0600PG45 CTFB50/0600PG45

750 N/A N/A CTFB50/0750PG45

900 N/A N/A CTFB50/0900PG45

Adjustable flat bends

(Not available for light duty cable tray)Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Medium duty Heavy dutymm

50 CTAB25/0050PG N/A

75 CTAB25/0075PG CTAB50/0075PG

100 CTAB25/0100PG CTAB50/0100PG

150 CTAB25/0150PG CTAB50/0150PG

225 CTAB25/0225PG CTAB50/0225PG

300 CTAB25/0300PG CTAB50/0300PG

Unequal tee (made to order)

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Equal tee

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Light duty Medium duty Heavy dutymm

50 CTET12/0050PG CTET25/0050PG N/A

75 CTET12/0075PG CTET25/0075PG CTET50/0075PG

100 CTET12/0100PG CTET25/0100PG CTET50/0100PG

150 CTET12/0150PG CTET25/0150PG CTET50/0150PG

225 CTET12/0225PG CTET25/0225PG CTET50/0225PG

300 CTET18/0300PG CTET25/0300PG CTET50/0300PG

450 N/A CTET25/0450PG CTET50/0450PG

600 N/A CTET25/0600PG CTET50/0600PG

750 N/A N/A CTET50/0750PG

900 N/A N/A CTET50/0900PG

Cable tray systemsCable tray systems

W1

W2

How to generate the part number - CTUT (depth)/W1/W2(finish)Example - CTUT 25/0300/0150/PGTable below shows a complete list of W1 and W2 combinations.

W1 W2 W1 W2 W1 W2 W1 W2

50 75 100 450 300 75 600 450

50 100 100 600 300 100 600 750

50 150 100 750 300 150 600 900

50 225 100 900 300 225 750 50

50 300 150 50 300 450 750 75

50 450 150 75 300 600 750 100

50 600 150 100 300 750 750 150

50 750 150 225 300 900 750 225

50 900 150 300 450 50 750 300

75 50 150 450 450 75 750 450

75 100 150 600 450 100 750 600

75 150 150 750 450 150 750 900

75 225 150 900 450 225 900 50

75 300 225 50 450 300 900 75

75 450 225 75 450 600 900 100

75 600 225 100 450 750 900 150

75 750 225 150 450 900 900 225

75 900 225 300 600 50 900 300

100 50 225 450 600 75 900 450

100 75 225 600 600 100 900 600

100 150 225 750 600 150 900 750

100 225 225 900 600 225

100 300 300 50 600 300

90

Page 11: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

Cable tray systems

40

90º flat bends

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Light duty Medium duty Heavy dutymm

50 CTFB12/0050PG90 CTFB25/0050PG90 N/A

75 CTFB12/0075PG90 CTFB25/0075PG90 CTFB50/0075PG90

100 CTFB12/0100PG90 CTFB25/0100PG90 CTFB50/0100PG90

150 CTFB12/0150PG90 CTFB25/0150PG90 CTFB50/0150PG90

225 CTFB12/0225PG90 CTFB25/0225PG90 CTFB50/0225PG90

300 CTFB18/0300PG90 CTFB25/0300PG90 CTFB50/0300PG90

450 N/A CTFB25/0450PG90 CTFB50/0450PG90

600 N/A CTFB25/0600PG90 CTFB50/0600PG90

750 N/A N/A CTFB50/0750PG90

900 N/A N/A CTFB50/0900PG90

45º flat bends

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Light duty Medium duty Heavy dutymm

50 CTFB12/0050PG45 CTFB25/0050PG45 N/A

75 CTFB12/0075PG45 CTFB25/0075PG45 CTFB50/0075PG45

100 CTFB12/0100PG45 CTFB25/0100PG45 CTFB50/0100PG45

150 CTFB12/0150PG45 CTFB25/0150PG45 CTFB50/0150PG45

225 CTFB12/0225PG45 CTFB25/0225PG45 CTFB50/0225PG45

300 CTFB18/0300PG45 CTFB25/0300PG45 CTFB50/0300PG45

450 N/A CTFB25/0450PG45 CTFB50/0450PG45

600 N/A CTFB25/0600PG45 CTFB50/0600PG45

750 N/A N/A CTFB50/0750PG45

900 N/A N/A CTFB50/0900PG45

Adjustable flat bends

(Not available for light duty cable tray)Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Medium duty Heavy dutymm

50 CTAB25/0050PG N/A

75 CTAB25/0075PG CTAB50/0075PG

100 CTAB25/0100PG CTAB50/0100PG

150 CTAB25/0150PG CTAB50/0150PG

225 CTAB25/0225PG CTAB50/0225PG

300 CTAB25/0300PG CTAB50/0300PG

Unequal tee (made to order)

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Equal tee

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Light duty Medium duty Heavy dutymm

50 CTET12/0050PG CTET25/0050PG N/A

75 CTET12/0075PG CTET25/0075PG CTET50/0075PG

100 CTET12/0100PG CTET25/0100PG CTET50/0100PG

150 CTET12/0150PG CTET25/0150PG CTET50/0150PG

225 CTET12/0225PG CTET25/0225PG CTET50/0225PG

300 CTET18/0300PG CTET25/0300PG CTET50/0300PG

450 N/A CTET25/0450PG CTET50/0450PG

600 N/A CTET25/0600PG CTET50/0600PG

750 N/A N/A CTET50/0750PG

900 N/A N/A CTET50/0900PG

Cable tray systemsCable tray systems

W1

W2

How to generate the part number - CTUT (depth)/W1/W2(finish)Example - CTUT 25/0300/0150/PGTable below shows a complete list of W1 and W2 combinations.

W1 W2 W1 W2 W1 W2 W1 W2

50 75 100 450 300 75 600 450

50 100 100 600 300 100 600 750

50 150 100 750 300 150 600 900

50 225 100 900 300 225 750 50

50 300 150 50 300 450 750 75

50 450 150 75 300 600 750 100

50 600 150 100 300 750 750 150

50 750 150 225 300 900 750 225

50 900 150 300 450 50 750 300

75 50 150 450 450 75 750 450

75 100 150 600 450 100 750 600

75 150 150 750 450 150 750 900

75 225 150 900 450 225 900 50

75 300 225 50 450 300 900 75

75 450 225 75 450 600 900 100

75 600 225 100 450 750 900 150

75 750 225 150 450 900 900 225

75 900 225 300 600 50 900 300

100 50 225 450 600 75 900 450

100 75 225 600 600 100 900 600

100 150 225 750 600 150 900 750

100 225 225 900 600 225

100 300 300 50 600 300

91

Page 12: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

43

Cable tray systemsCrossovers

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Light duty Medium duty Heavy dutymm

50 CTCO12/0050PG CTCO25/0050PG N/A

75 CTCO12/0075PG CTCO25/0075PG CTCO50/0075PG

100 CTCO12/0100PG CTCO25/0100PG CTCO50/0100PG

150 CTCO12/0150PG CTCO25/0150PG CTCO50/0150PG

225 CTCO12/0225PG CTCO25/0225PG CTCO50/0225PG

300 CTCO18/0300PG CTCO25/0300PG CTCO50/0300PG

450 N/A CTCO25/0450PG CTCO50/0450PG

600 N/A CTCO25/0600PG CTCO50/0600PG

750 N/A N/A CTCO50/0750PG

900 N/A N/A CTCO50/0900PG

Internal riser - flexible

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSCTFR = Flexible risers are supplied flat and folded on site to suit angle.CTIR = Internal risers are folded to suit stated angle. 90 = 90°, 60 = 60°, 45 = 45°, 30 = 30°Eg: CTIR50/0900PG90

Width Light duty Medium duty Heavy dutymm

50 CTFR12/0050PG CTFR25/0050PG N/A

75 CTFR12/0075PG CTFR25/0075PG CTFR50/0075PG

100 CTFR12/0100PG CTFR25/0100PG CTFR50/0100PG

150 CTFR12/0150PG CTFR25/0150PG CTFR50/0150PG

225 CTFR12/0225PG CTFR25/0225PG CTFR50/0225PG

300 CTFR18/0300PG CTFR25/0300PG CTFR50/0300PG

450 N/A CTFR25/0450PG CTFR50/0450PG

600 N/A CTFR25/0600PG CTFR50/0600PG

750 N/A N/A CTIR50/0750PG90 (only available pre-folded)

900 N/A N/A CTIR50/0900PG90 (only available pre-folded)

External riser - flexible

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSCTFR = Flexible risers are supplied flat and folded on site to suit angle.CTER = External risers are folded to suit stated angle. 90 = 90°, 60 = 60°, 45 = 45°, 30 = 30°Eg: CTER50/0900PG90

Width Light duty Medium duty Heavy dutymm

50 CTFR12/0050PG CTFR25/0050PG N/A

75 CTFR12/0075PG CTFR25/0075PG CTFR50/0075PG

100 CTFR12/0100PG CTFR25/0100PG CTFR50/0100PG

150 CTFR12/0150PG CTFR25/0150PG CTFR50/0150PG

225 CTFR12/0225PG CTFR25/0225PG CTFR50/0225PG

300 CTFR18/0300PG CTFR25/0300PG CTFR50/0300PG

450 N/A CTFR25/0450PG CTFR50/0450PG

600 N/A CTFR25/0600PG CTFR50/0600PG

750 N/A N/A CTER50/0750PG90 (only available pre-folded)

900 N/A N/A CTER50/0900PG90 (only available pre-folded)

Reducers

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Light duty Medium duty Heavy dutymmW1 W2

75 50 CTSR12/0075/0050PG CTSR25/0075/0050PG N/A

100 50 CTSR12/0100/0050PG CTSR25/0100/0050PG N/A

150 50 CTSR12/0150/0050PG CTSR25/0150/0050PG N/A

225 50 CTSR12/0225/0050PG CTSR25/0225/0050PG N/A

300 50 CTSR18/0300/0050PG CTSR25/0300/0050PG N/A

450 50 N/A CTSR25/0450/0050PG N/A

600 50 N/A CTSR25/0600/0050PG N/A

750 50 N/A N/A N/A

900 50 N/A N/A N/A

100 75 CTSR12/0100/0075PG CTSR25/0100/0075PG CTSR50/0100/0075PG

150 75 CTSR12/0150/0075PG CTSR25/0150/0075PG CTSR50/0150/0075PG

225 75 CTSR12/0225/0075PG CTSR25/0225/0075PG CTSR50/0225/0075PG

300 75 CTSR18/0300/0075PG CTSR25/0300/0075PG CTSR50/0300/0075PG

450 75 N/A CTSR25/0450/0075PG CTSR50/0450/0075PG

600 75 N/A CTSR25/0600/0075PG CTSR50/0600/0075PG

750 75 N/A N/A CTSR50/0750/0075PG

900 75 N/A N/A CTSR50/0900/0075PG

150 100 CTSR12/0150/0100PG CTSR25/0150/0100PG CTSR50/0150/0100PG

225 100 CTSR12/0225/0100PG CTSR25/0225/0100PG CTSR50/0225/0100PG

300 100 CTSR18/0300/0100PG CTSR25/0300/0100PG CTSR50/0300/0100PG

450 100 N/A CTSR25/0450/0100PG CTSR50/0450/0100PG

600 100 N/A CTSR25/0600/0100PG CTSR50/0600/0100PG

750 100 N/A N/A CTSR50/0750/0100PG

900 100 N/A N/A CTSR50/0900/0100PG

225 150 CTSR12/0225/0150PG CTSR25/0225/0150PG CTSR50/0225/0150PG

300 150 CTSR18/0300/0150PG CTSR25/0300/0150PG CTSR50/0300/0150PG

450 150 N/A CTSR25/0450/0150PG CTSR50/0450/0150PG

600 150 N/A CTSR25/0600/0150PG CTSR50/0600/0150PG

750 150 N/A N/A CTSR50/0750/0150PG

900 150 N/A N/A CTSR50/0900/0150PG

300 225 CTSR18/0300/0225PG CTSR25/0300/0225PG CTSR50/0300/0225PG

450 225 N/A CTSR25/0450/0225PG CTSR50/0450/0225PG

600 225 N/A CTSR25/0600/0225PG CTSR50/0600/0225PG

750 225 N/A N/A CTSR50/0750/0225PG

900 225 N/A N/A CTSR50/0900/0225PG

450 300 N/A CTSR25/0450/0300PG CTSR50/0450/0300PG

600 300 N/A CTSR25/0600/0300PG CTSR50/0600/0300PG

750 300 N/A N/A CTSR50/0750/0300PG

900 300 N/A N/A CTSR50/0900/0300PG

600 450 N/A CTSR25/0600/0450PG CTSR50/0600/0450PG

750 450 N/A N/A CTSR50/0750/0450PG

900 450 N/A N/A CTSR50/0900/0450PG

750 600 N/A N/A CTSR50/0750/0600PG

900 600 N/A N/A CTSR50/0900/0600PG

900 750 N/A N/A CTSR50/0900/0750PG

Cable tray systemsCable tray systems

W1

W2

92

Page 13: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

Cable tray systems

42

Crossovers

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Light duty Medium duty Heavy dutymm

50 CTCO12/0050PG CTCO25/0050PG N/A

75 CTCO12/0075PG CTCO25/0075PG CTCO50/0075PG

100 CTCO12/0100PG CTCO25/0100PG CTCO50/0100PG

150 CTCO12/0150PG CTCO25/0150PG CTCO50/0150PG

225 CTCO12/0225PG CTCO25/0225PG CTCO50/0225PG

300 CTCO18/0300PG CTCO25/0300PG CTCO50/0300PG

450 N/A CTCO25/0450PG CTCO50/0450PG

600 N/A CTCO25/0600PG CTCO50/0600PG

750 N/A N/A CTCO50/0750PG

900 N/A N/A CTCO50/0900PG

Internal riser - flexible

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSCTFR = Flexible risers are supplied flat and folded on site to suit angle.CTIR = Internal risers are folded to suit stated angle. 90 = 90°, 60 = 60°, 45 = 45°, 30 = 30°Eg: CTIR50/0900PG90

Width Light duty Medium duty Heavy dutymm

50 CTFR12/0050PG CTFR25/0050PG N/A

75 CTFR12/0075PG CTFR25/0075PG CTFR50/0075PG

100 CTFR12/0100PG CTFR25/0100PG CTFR50/0100PG

150 CTFR12/0150PG CTFR25/0150PG CTFR50/0150PG

225 CTFR12/0225PG CTFR25/0225PG CTFR50/0225PG

300 CTFR18/0300PG CTFR25/0300PG CTFR50/0300PG

450 N/A CTFR25/0450PG CTFR50/0450PG

600 N/A CTFR25/0600PG CTFR50/0600PG

750 N/A N/A CTIR50/0750PG90 (only available pre-folded)

900 N/A N/A CTIR50/0900PG90 (only available pre-folded)

External riser - flexible

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSCTFR = Flexible risers are supplied flat and folded on site to suit angle.CTER = External risers are folded to suit stated angle. 90 = 90°, 60 = 60°, 45 = 45°, 30 = 30°Eg: CTER50/0900PG90

Width Light duty Medium duty Heavy dutymm

50 CTFR12/0050PG CTFR25/0050PG N/A

75 CTFR12/0075PG CTFR25/0075PG CTFR50/0075PG

100 CTFR12/0100PG CTFR25/0100PG CTFR50/0100PG

150 CTFR12/0150PG CTFR25/0150PG CTFR50/0150PG

225 CTFR12/0225PG CTFR25/0225PG CTFR50/0225PG

300 CTFR18/0300PG CTFR25/0300PG CTFR50/0300PG

450 N/A CTFR25/0450PG CTFR50/0450PG

600 N/A CTFR25/0600PG CTFR50/0600PG

750 N/A N/A CTER50/0750PG90 (only available pre-folded)

900 N/A N/A CTER50/0900PG90 (only available pre-folded)

Reducers

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Width Light duty Medium duty Heavy dutymmW1 W2

75 50 CTSR12/0075/0050PG CTSR25/0075/0050PG N/A

100 50 CTSR12/0100/0050PG CTSR25/0100/0050PG N/A

150 50 CTSR12/0150/0050PG CTSR25/0150/0050PG N/A

225 50 CTSR12/0225/0050PG CTSR25/0225/0050PG N/A

300 50 CTSR18/0300/0050PG CTSR25/0300/0050PG N/A

450 50 N/A CTSR25/0450/0050PG N/A

600 50 N/A CTSR25/0600/0050PG N/A

750 50 N/A N/A N/A

900 50 N/A N/A N/A

100 75 CTSR12/0100/0075PG CTSR25/0100/0075PG CTSR50/0100/0075PG

150 75 CTSR12/0150/0075PG CTSR25/0150/0075PG CTSR50/0150/0075PG

225 75 CTSR12/0225/0075PG CTSR25/0225/0075PG CTSR50/0225/0075PG

300 75 CTSR18/0300/0075PG CTSR25/0300/0075PG CTSR50/0300/0075PG

450 75 N/A CTSR25/0450/0075PG CTSR50/0450/0075PG

600 75 N/A CTSR25/0600/0075PG CTSR50/0600/0075PG

750 75 N/A N/A CTSR50/0750/0075PG

900 75 N/A N/A CTSR50/0900/0075PG

150 100 CTSR12/0150/0100PG CTSR25/0150/0100PG CTSR50/0150/0100PG

225 100 CTSR12/0225/0100PG CTSR25/0225/0100PG CTSR50/0225/0100PG

300 100 CTSR18/0300/0100PG CTSR25/0300/0100PG CTSR50/0300/0100PG

450 100 N/A CTSR25/0450/0100PG CTSR50/0450/0100PG

600 100 N/A CTSR25/0600/0100PG CTSR50/0600/0100PG

750 100 N/A N/A CTSR50/0750/0100PG

900 100 N/A N/A CTSR50/0900/0100PG

225 150 CTSR12/0225/0150PG CTSR25/0225/0150PG CTSR50/0225/0150PG

300 150 CTSR18/0300/0150PG CTSR25/0300/0150PG CTSR50/0300/0150PG

450 150 N/A CTSR25/0450/0150PG CTSR50/0450/0150PG

600 150 N/A CTSR25/0600/0150PG CTSR50/0600/0150PG

750 150 N/A N/A CTSR50/0750/0150PG

900 150 N/A N/A CTSR50/0900/0150PG

300 225 CTSR18/0300/0225PG CTSR25/0300/0225PG CTSR50/0300/0225PG

450 225 N/A CTSR25/0450/0225PG CTSR50/0450/0225PG

600 225 N/A CTSR25/0600/0225PG CTSR50/0600/0225PG

750 225 N/A N/A CTSR50/0750/0225PG

900 225 N/A N/A CTSR50/0900/0225PG

450 300 N/A CTSR25/0450/0300PG CTSR50/0450/0300PG

600 300 N/A CTSR25/0600/0300PG CTSR50/0600/0300PG

750 300 N/A N/A CTSR50/0750/0300PG

900 300 N/A N/A CTSR50/0900/0300PG

600 450 N/A CTSR25/0600/0450PG CTSR50/0600/0450PG

750 450 N/A N/A CTSR50/0750/0450PG

900 450 N/A N/A CTSR50/0900/0450PG

750 600 N/A N/A CTSR50/0750/0600PG

900 600 N/A N/A CTSR50/0900/0600PG

900 750 N/A N/A CTSR50/0900/0750PG

Cable tray systemsCable tray systems

W1

W2

93

Page 14: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

45

Cable tray systemsFishplate couplers

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Widthmm (always required for cut lengths of light duty tray)

50 CTFP1PG

75 CTFP1PG

100 CTFP1PG

150 CTFP1PG

225 CTFP2PG

300 CTFP2PG

450 CTFP2PG

600 CTFP2PG

750 CTFP2PG

900 CTFP2PG

Cover - straight length - 3m long

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 6 fixing clamps and fasteners

Width Light duty Medium duty Heavy duty

50 CTSL12CV/050PG CTSL25CC/050PG N/A

75 CTSL12CV/075PG CTSL25CC/075PG CTSL50CC/075PG

100 CTSL12CV/100PG CTSL25CC/100PG CTSL50CC/100PG

150 CTSL12CV/150PG CTSL25CC/150PG CTSL50CC/150PG

225 CTSL12CV/225PG CTSL25CC/225PG CTSL50CC/225PG

300 CTSL18CV/300PG CTSL25CC/300PG CTSL50CC/300PG

450 N/A CTSL25CC/450PG CTSL50CC/450PG

600 N/A CTSL25CC/600PG CTSL50CC/600PG

750 N/A N/A CTSL50CC/750PG

900 N/A N/A CTSL50CC/900PG

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Cover - 90º flat bends

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 5 fixing clamps and fasteners

Width Light duty Medium duty Heavy duty

50 CTFB12CV/050PG90 CTFB25CC/050PG90 N/A

75 CTFB12CV/075PG90 CTFB25CC/075PG90 CTFB50CC/075PG90

100 CTFB12CV/100PG90 CTFB25CC/100PG90 CTFB50CC/100PG90

150 CTFB12CV/150PG90 CTFB25CC/150PG90 CTFB50CC/150PG90

225 CTFB12CV/225PG90 CTFB25CC/225PG90 CTFB50CC/225PG90

300 CTFB18CV/300PG90 CTFB25CC/300PG90 CTFB50CC/300PG90

450 N/A CTFB25CC/450PG90 CTFB50CC/450PG90

600 N/A CTFB25CC/600PG90 CTFB50CC/600PG90

750 N/A N/A CTFB50CC/750PG90

900 N/A N/A CTFB50CC/900PG90

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Extra cover clips

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CV

Duty Standard Ventilated

Light N/A CTCCV18HDG

Medium CTCCC25HDG CTCCV25HDG

Heavy CTCCC50HDG CTCCV50HDG

Cover - 45º flat bends

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 5 fixing clamps and fasteners

Width Light duty Medium duty Heavy duty

50 CTFB12CV/050PG45 CTFB25CC/050PG45 N/A

75 CTFB12CV/075PG45 CTFB25CC/075PG45 CTFB50CC/075PG45

100 CTFB12CV/100PG45 CTFB25CC/100PG45 CTFB50CC/100PG45

150 CTFB12CV/150PG45 CTFB25CC/150PG45 CTFB50CC/150PG45

225 CTFB12CV/225PG45 CTFB25CC/225PG45 CTFB50CC/225PG45

300 CTFB18CV/300PG45 CTFB25CC/300PG45 CTFB50CC/300PG45

450 N/A CTFB25CC/450PG45 CTFB50CC/450PG45

600 N/A CTFB25CC/600PG45 CTFB50CC/600PG45

750 N/A N/A CTFB50CC/750PG45

900 N/A N/A CTFB50CC/900PG45

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Cover - crossover

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 4 fixing clamps and fasteners

Width Light duty Medium duty Heavy duty

50 CTCO12CV/050PG CTCO25CC/050PG N/A

75 CTCO12CV/075PG CTCO25CC/075PG CTCO50CC/075PG

100 CTCO12CV/100PG CTCO25CC/100PG CTCO50CC/100PG

150 CTCO12CV/150PG CTCO25CC/150PG CTCO50CC/150PG

225 CTCO12CV/225PG CTCO25CC/225PG CTCO50CC/225PG

300 CTCO18CV/300PG CTCO25CC/300PG CTCO50CC/300PG

450 N/A CTCO25CC/450PG CTCO50CC/450PG

600 N/A CTCO25CC/600PG CTCO50CC/600PG

750 N/A N/A CTCO50CC/750PG

900 N/A N/A CTCO50CC/900PG

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Cover - equal tee

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 5 fixing clamps and fasteners

Width Light duty Medium duty Heavy duty

50 CTET12CV/050PG CTET25CC/050PG N/A

75 CTET12CV/075PG CTET25CC/075PG CTET50CC/075PG

100 CTET12CV/100PG CTET25CC/100PG CTET50CC/100PG

150 CTET12CV/150PG CTET25CC/150PG CTET50CC/150PG

225 CTET12CV/225PG CTET25CC/225PG CTET50CC/225PG

300 CTET18CV/300PG CTET25CC/300PG CTET50CC/300PG

450 N/A CTET25CC/450PG CTET50CC/450PG

600 N/A CTET25CC/600PG CTET50CC/600PG

750 N/A N/A CTET50CC/750PG

900 N/A N/A CTET50CC/900PG

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Cable tray systemsCable tray systems

94

Page 15: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

Cable tray systems

44

Fishplate couplers

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Widthmm (always required for cut lengths of light duty tray)

50 CTFP1PG

75 CTFP1PG

100 CTFP1PG

150 CTFP1PG

225 CTFP2PG

300 CTFP2PG

450 CTFP2PG

600 CTFP2PG

750 CTFP2PG

900 CTFP2PG

Cover - straight length - 3m long

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 6 fixing clamps and fasteners

Width Light duty Medium duty Heavy duty

50 CTSL12CV/050PG CTSL25CC/050PG N/A

75 CTSL12CV/075PG CTSL25CC/075PG CTSL50CC/075PG

100 CTSL12CV/100PG CTSL25CC/100PG CTSL50CC/100PG

150 CTSL12CV/150PG CTSL25CC/150PG CTSL50CC/150PG

225 CTSL12CV/225PG CTSL25CC/225PG CTSL50CC/225PG

300 CTSL18CV/300PG CTSL25CC/300PG CTSL50CC/300PG

450 N/A CTSL25CC/450PG CTSL50CC/450PG

600 N/A CTSL25CC/600PG CTSL50CC/600PG

750 N/A N/A CTSL50CC/750PG

900 N/A N/A CTSL50CC/900PG

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Cover - 90º flat bends

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 5 fixing clamps and fasteners

Width Light duty Medium duty Heavy duty

50 CTFB12CV/050PG90 CTFB25CC/050PG90 N/A

75 CTFB12CV/075PG90 CTFB25CC/075PG90 CTFB50CC/075PG90

100 CTFB12CV/100PG90 CTFB25CC/100PG90 CTFB50CC/100PG90

150 CTFB12CV/150PG90 CTFB25CC/150PG90 CTFB50CC/150PG90

225 CTFB12CV/225PG90 CTFB25CC/225PG90 CTFB50CC/225PG90

300 CTFB18CV/300PG90 CTFB25CC/300PG90 CTFB50CC/300PG90

450 N/A CTFB25CC/450PG90 CTFB50CC/450PG90

600 N/A CTFB25CC/600PG90 CTFB50CC/600PG90

750 N/A N/A CTFB50CC/750PG90

900 N/A N/A CTFB50CC/900PG90

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Extra cover clips

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CV

Duty Standard Ventilated

Light N/A CTCCV18HDG

Medium CTCCC25HDG CTCCV25HDG

Heavy CTCCC50HDG CTCCV50HDG

Cover - 45º flat bends

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 5 fixing clamps and fasteners

Width Light duty Medium duty Heavy duty

50 CTFB12CV/050PG45 CTFB25CC/050PG45 N/A

75 CTFB12CV/075PG45 CTFB25CC/075PG45 CTFB50CC/075PG45

100 CTFB12CV/100PG45 CTFB25CC/100PG45 CTFB50CC/100PG45

150 CTFB12CV/150PG45 CTFB25CC/150PG45 CTFB50CC/150PG45

225 CTFB12CV/225PG45 CTFB25CC/225PG45 CTFB50CC/225PG45

300 CTFB18CV/300PG45 CTFB25CC/300PG45 CTFB50CC/300PG45

450 N/A CTFB25CC/450PG45 CTFB50CC/450PG45

600 N/A CTFB25CC/600PG45 CTFB50CC/600PG45

750 N/A N/A CTFB50CC/750PG45

900 N/A N/A CTFB50CC/900PG45

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Cover - crossover

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 4 fixing clamps and fasteners

Width Light duty Medium duty Heavy duty

50 CTCO12CV/050PG CTCO25CC/050PG N/A

75 CTCO12CV/075PG CTCO25CC/075PG CTCO50CC/075PG

100 CTCO12CV/100PG CTCO25CC/100PG CTCO50CC/100PG

150 CTCO12CV/150PG CTCO25CC/150PG CTCO50CC/150PG

225 CTCO12CV/225PG CTCO25CC/225PG CTCO50CC/225PG

300 CTCO18CV/300PG CTCO25CC/300PG CTCO50CC/300PG

450 N/A CTCO25CC/450PG CTCO50CC/450PG

600 N/A CTCO25CC/600PG CTCO50CC/600PG

750 N/A N/A CTCO50CC/750PG

900 N/A N/A CTCO50CC/900PG

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Cover - equal tee

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 5 fixing clamps and fasteners

Width Light duty Medium duty Heavy duty

50 CTET12CV/050PG CTET25CC/050PG N/A

75 CTET12CV/075PG CTET25CC/075PG CTET50CC/075PG

100 CTET12CV/100PG CTET25CC/100PG CTET50CC/100PG

150 CTET12CV/150PG CTET25CC/150PG CTET50CC/150PG

225 CTET12CV/225PG CTET25CC/225PG CTET50CC/225PG

300 CTET18CV/300PG CTET25CC/300PG CTET50CC/300PG

450 N/A CTET25CC/450PG CTET50CC/450PG

600 N/A CTET25CC/600PG CTET50CC/600PG

750 N/A N/A CTET50CC/750PG

900 N/A N/A CTET50CC/900PG

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Cable tray systemsCable tray systems

95

Page 16: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

47

Cable tray systemsCover - unequal tee (made to order)

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 5 fixing clamps and fasteners

Cover - reducer

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 4 fixing clamps and fasteners

Width Light duty Medium duty Heavy duty mmW1 W2

75 50 CTSRCV12/0075/0050PG CTSRCC25/0075/0050PG N/A

100 50 CTSRCV12/0100/0050PG CTSRCC25/0100/0050PG N/A

150 50 CTSRCV12/0150/0050PG CTSRCC25/0150/0050PG N/A

225 50 CTSRCV12/0225/0050PG CTSRCC25/0225/0050PG N/A

300 50 N/A CTSRCC25/0300/0050PG N/A

450 50 N/A CTSRCC25/0450/0050PG N/A

600 50 N/A CTSRCC25/0600/0050PG N/A

750 50 N/A N/A N/A

900 50 N/A N/A N/A

100 75 CTSRCV12/0100/0075PG CTSRCC25/0100/0075PG CTSRCC50/0100/0075PG

150 75 CTSRCV12/0150/0075PG CTSRCC25/0150/0075PG CTSRCC50/0150/0075PG

225 75 CTSRCV12/0225/0075PG CTSRCC25/0225/0075PG CTSRCC50/0225/0075PG

300 75 CTSRCV18/0300/0075PG CTSRCC25/0300/0075PG CTSRCC50/0300/0075PG

450 75 N/A CTSRCC25/0450/0075PG CTSRCC50/0450/0075PG

600 75 N/A CTSRCC25/0600/0075PG CTSRCC50/0600/0075PG

750 75 N/A N/A CTSRCC50/0750/0075PG

900 75 N/A N/A CTSRCC50/0900/0075PG

150 100 CTSRCV12/0150/0100PG CTSRCC25/0150/0100PG CTSRCC50/0150/0100PG

225 100 CTSRCV12/0225/0100PG CTSRCC25/0225/0100PG CTSRCC50/0225/0100PG

300 100 CTSRCV18/0300/0100PG CTSRCC25/0300/0100PG CTSRCC50/0300/0100PG

450 100 N/A CTSRCC25/0450/0100PG CTSRCC50/0450/0100PG

600 100 N/A CTSRCC25/0600/0100PG CTSRCC50/0600/0100PG

750 100 N/A N/A CTSRCC50/0750/0100PG

900 100 N/A N/A CTSRCC50/0900/0100PG

225 150 CTSRCV12/0225/0150PG CTSRCC25/0225/0150PG CTSRCC50/0225/0150PG

300 150 CTSRCV18/0300/0150PG CTSRCC25/0300/0150PG CTSRCC50/0300/0150PG

450 150 N/A CTSRCC25/0450/0150PG CTSRCC50/0450/0150PG

600 150 N/A CTSRCC25/0600/0150PG CTSRCC50/0600/0150PG

750 150 N/A N/A CTSRCC50/0750/0150PG

900 150 N/A N/A CTSRCC50/0900/0150PG

300 225 CTSRCV18/0300/0225PG CTSRCC25/0300/0225PG CTSRCC50/0300/0225PG

450 225 N/A CTSRCC25/0450/0225PG CTSRCC50/0450/0225PG

600 225 N/A CTSRCC25/0600/0225PG CTSRCC50/0600/0225PG

750 225 N/A N/A CTSRCC50/0750/0225PG

900 225 N/A N/A CTSRCC50/0900/0225PG

450 300 N/A CTSRCC25/0450/0300PG CTSRCC50/0450/0300PG

600 300 N/A CTSRCC25/0600/0300PG CTSRCC50/0600/0300PG

750 300 N/A N/A CTSRCC50/0750/0300PG

900 300 N/A N/A CTSRCC50/0900/0300PG

600 450 N/A CTSRCC25/0600/0450PG CTSRCC50/0600/0450PG

750 450 N/A N/A CTSRCC50/0750/0450PG

900 450 N/A N/A CTSRCC50/0900/0450PG

750 600 N/A N/A CTSRCC50/0750/0600PG

900 600 N/A N/A CTSRCC50/0900/0600PG

900 750 N/A N/A CTSRCC50/0900/0750PG

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Cable tray systemsCable tray systems

W1W2

W1

W2

How to generate the part number - CTUT (cover type) (depth)/W1/W2(finish)Example - CTUT CC 25/300/150PGTable below shows a complete list of W1 and W2 combinations.

W1 W2 W1 W2 W1 W2 W1 W2

50 75 100 450 300 75 600 450

50 100 100 600 300 100 600 750

50 150 100 750 300 150 600 900

50 225 100 900 300 225 750 50

50 300 150 50 300 450 750 75

50 450 150 75 300 600 750 100

50 600 150 100 300 750 750 150

50 750 150 225 300 900 750 225

50 900 150 300 450 50 750 300

75 50 150 450 450 75 750 450

75 100 150 600 450 100 750 600

75 150 150 750 450 150 750 900

75 225 150 900 450 225 900 50

75 300 225 50 450 300 900 75

75 450 225 75 450 600 900 100

75 600 225 100 450 750 900 150

75 750 225 150 450 900 900 225

75 900 225 300 600 50 900 300

100 50 225 450 600 75 900 450

100 75 225 600 600 100 900 600

100 150 225 750 600 150 900 750

100 225 225 900 600 225

100 300 300 50 600 300

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

96

Page 17: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

Cable tray systems

46

Cover - unequal tee (made to order)

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 5 fixing clamps and fasteners

Cover - reducer

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 4 fixing clamps and fasteners

Width Light duty Medium duty Heavy duty mmW1 W2

75 50 CTSRCV12/0075/0050PG CTSRCC25/0075/0050PG N/A

100 50 CTSRCV12/0100/0050PG CTSRCC25/0100/0050PG N/A

150 50 CTSRCV12/0150/0050PG CTSRCC25/0150/0050PG N/A

225 50 CTSRCV12/0225/0050PG CTSRCC25/0225/0050PG N/A

300 50 N/A CTSRCC25/0300/0050PG N/A

450 50 N/A CTSRCC25/0450/0050PG N/A

600 50 N/A CTSRCC25/0600/0050PG N/A

750 50 N/A N/A N/A

900 50 N/A N/A N/A

100 75 CTSRCV12/0100/0075PG CTSRCC25/0100/0075PG CTSRCC50/0100/0075PG

150 75 CTSRCV12/0150/0075PG CTSRCC25/0150/0075PG CTSRCC50/0150/0075PG

225 75 CTSRCV12/0225/0075PG CTSRCC25/0225/0075PG CTSRCC50/0225/0075PG

300 75 CTSRCV18/0300/0075PG CTSRCC25/0300/0075PG CTSRCC50/0300/0075PG

450 75 N/A CTSRCC25/0450/0075PG CTSRCC50/0450/0075PG

600 75 N/A CTSRCC25/0600/0075PG CTSRCC50/0600/0075PG

750 75 N/A N/A CTSRCC50/0750/0075PG

900 75 N/A N/A CTSRCC50/0900/0075PG

150 100 CTSRCV12/0150/0100PG CTSRCC25/0150/0100PG CTSRCC50/0150/0100PG

225 100 CTSRCV12/0225/0100PG CTSRCC25/0225/0100PG CTSRCC50/0225/0100PG

300 100 CTSRCV18/0300/0100PG CTSRCC25/0300/0100PG CTSRCC50/0300/0100PG

450 100 N/A CTSRCC25/0450/0100PG CTSRCC50/0450/0100PG

600 100 N/A CTSRCC25/0600/0100PG CTSRCC50/0600/0100PG

750 100 N/A N/A CTSRCC50/0750/0100PG

900 100 N/A N/A CTSRCC50/0900/0100PG

225 150 CTSRCV12/0225/0150PG CTSRCC25/0225/0150PG CTSRCC50/0225/0150PG

300 150 CTSRCV18/0300/0150PG CTSRCC25/0300/0150PG CTSRCC50/0300/0150PG

450 150 N/A CTSRCC25/0450/0150PG CTSRCC50/0450/0150PG

600 150 N/A CTSRCC25/0600/0150PG CTSRCC50/0600/0150PG

750 150 N/A N/A CTSRCC50/0750/0150PG

900 150 N/A N/A CTSRCC50/0900/0150PG

300 225 CTSRCV18/0300/0225PG CTSRCC25/0300/0225PG CTSRCC50/0300/0225PG

450 225 N/A CTSRCC25/0450/0225PG CTSRCC50/0450/0225PG

600 225 N/A CTSRCC25/0600/0225PG CTSRCC50/0600/0225PG

750 225 N/A N/A CTSRCC50/0750/0225PG

900 225 N/A N/A CTSRCC50/0900/0225PG

450 300 N/A CTSRCC25/0450/0300PG CTSRCC50/0450/0300PG

600 300 N/A CTSRCC25/0600/0300PG CTSRCC50/0600/0300PG

750 300 N/A N/A CTSRCC50/0750/0300PG

900 300 N/A N/A CTSRCC50/0900/0300PG

600 450 N/A CTSRCC25/0600/0450PG CTSRCC50/0600/0450PG

750 450 N/A N/A CTSRCC50/0750/0450PG

900 450 N/A N/A CTSRCC50/0900/0450PG

750 600 N/A N/A CTSRCC50/0750/0600PG

900 600 N/A N/A CTSRCC50/0900/0600PG

900 750 N/A N/A CTSRCC50/0900/0750PG

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Cable tray systemsCable tray systems

W1W2

W1

W2

How to generate the part number - CTUT (cover type) (depth)/W1/W2(finish)Example - CTUT CC 25/300/150PGTable below shows a complete list of W1 and W2 combinations.

W1 W2 W1 W2 W1 W2 W1 W2

50 75 100 450 300 75 600 450

50 100 100 600 300 100 600 750

50 150 100 750 300 150 600 900

50 225 100 900 300 225 750 50

50 300 150 50 300 450 750 75

50 450 150 75 300 600 750 100

50 600 150 100 300 750 750 150

50 750 150 225 300 900 750 225

50 900 150 300 450 50 750 300

75 50 150 450 450 75 750 450

75 100 150 600 450 100 750 600

75 150 150 750 450 150 750 900

75 225 150 900 450 225 900 50

75 300 225 50 450 300 900 75

75 450 225 75 450 600 900 100

75 600 225 100 450 750 900 150

75 750 225 150 450 900 900 225

75 900 225 300 600 50 900 300

100 50 225 450 600 75 900 450

100 75 225 600 600 100 900 600

100 150 225 750 600 150 900 750

100 225 225 900 600 225

100 300 300 50 600 300

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

97

Page 18: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

49

Cable tray systemsCover - 90º internal riser

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 8 fixing clamps and fasteners

Width Light duty Medium duty Heavy dutymm

50 CTIR12CV/0050PG90 CTIR25CC/0050PG90 N/A

75 CTIR12CV/0075PG90 CTIR25CC/0075PG90 CTIR50CC/0075PG90

100 CTIR12CV/0100PG90 CTIR25CC/0100PG90 CTIR50CC/0100PG90

150 CTIR12CV/0150PG90 CTIR25CC/0150PG90 CTIR50CC/0150PG90

225 CTIR12CV/0225PG90 CTIR25CC/0225PG90 CTIR50CC/0225PG90

300 CTIR18CV/0300PG90 CTIR25CC/0300PG90 CTIR50CC/0300PG90

450 N/A CTIR25CC/0450PG90 CTIR50CC/0450PG90

600 N/A CTIR25CC/0600PG90 CTIR50CC/0600PG90

750 N/A N/A CTIR50CC/0750PG90

900 N/A N/A CTIR50CC/0900PG90

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Cover - 90º external riser

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 8 fixing clamps and fasteners

Width Light duty Medium duty Heavy dutymm

50 CTER12CV/0050PG90 CTER25CC/0050PG90 N/A

75 CTER12CV/0075PG90 CTER25CC/0075PG90 CTER50CC/0075PG90

100 CTER12CV/0100PG90 CTER25CC/0100PG90 CTER50CC/0100PG90

150 CTER12CV/0150PG90 CTER25CC/0150PG90 CTER50CC/0150PG90

225 CTER12CV/0225PG90 CTER25CC/0225PG90 CTER50CC/0225PG90

300 CTER18CV/0300PG90 CTER25CC/0300PG90 CTER50CC/0300PG90

450 N/A CTER25CC/0450PG90 CTER50CC/0450PG90

600 N/A CTER25CC/0600PG90 CTER50CC/0600PG90

750 N/A N/A CTER50CC/0750PG90

900 N/A N/A CTER50CC/0900PG90

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Stand off brackets

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Widthmm

50 CTSO050PG

75 CTSO075PG

100 CTSO100PG

150 CTSO150PG

225 CTSO225PG

300 CTSO300PG

450 CTSO450PG

600 CTSO600PG

750 CTSO750PG

900 CTSO900PG

Hanger brackets

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Widthmm

50 CTHB050/PG

75 CTHB075/PG

100 CTHB100/PG

150 CTHB150/PG

Straight divider - 3m

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Tray depthmm

25 CTDI025PG3

50 CTDI050PG3

Earthing straps

Finish: electro-tinned

Use M6 x 12 roofing bolts Supplied in packs of 10

CT/ES100

Copper braid electro tinned 4mm2, 100mm long

Roofing bolts and nuts

Finish: BZP as standard, stainless steel grade 316 = SS

M6 x 12 roofing bolts

Supplied in packs of 100

M06X12RB

Cable tray systemsCable tray systems

98

Page 19: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

Cable tray systems

48

Cover - 90º internal riser

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 8 fixing clamps and fasteners

Width Light duty Medium duty Heavy dutymm

50 CTIR12CV/0050PG90 CTIR25CC/0050PG90 N/A

75 CTIR12CV/0075PG90 CTIR25CC/0075PG90 CTIR50CC/0075PG90

100 CTIR12CV/0100PG90 CTIR25CC/0100PG90 CTIR50CC/0100PG90

150 CTIR12CV/0150PG90 CTIR25CC/0150PG90 CTIR50CC/0150PG90

225 CTIR12CV/0225PG90 CTIR25CC/0225PG90 CTIR50CC/0225PG90

300 CTIR18CV/0300PG90 CTIR25CC/0300PG90 CTIR50CC/0300PG90

450 N/A CTIR25CC/0450PG90 CTIR50CC/0450PG90

600 N/A CTIR25CC/0600PG90 CTIR50CC/0600PG90

750 N/A N/A CTIR50CC/0750PG90

900 N/A N/A CTIR50CC/0900PG90

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Cover - 90º external riser

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SSStandard closed covers = CC, ventilated cover = CVIncludes 8 fixing clamps and fasteners

Width Light duty Medium duty Heavy dutymm

50 CTER12CV/0050PG90 CTER25CC/0050PG90 N/A

75 CTER12CV/0075PG90 CTER25CC/0075PG90 CTER50CC/0075PG90

100 CTER12CV/0100PG90 CTER25CC/0100PG90 CTER50CC/0100PG90

150 CTER12CV/0150PG90 CTER25CC/0150PG90 CTER50CC/0150PG90

225 CTER12CV/0225PG90 CTER25CC/0225PG90 CTER50CC/0225PG90

300 CTER18CV/0300PG90 CTER25CC/0300PG90 CTER50CC/0300PG90

450 N/A CTER25CC/0450PG90 CTER50CC/0450PG90

600 N/A CTER25CC/0600PG90 CTER50CC/0600PG90

750 N/A N/A CTER50CC/0750PG90

900 N/A N/A CTER50CC/0900PG90

*NB. Closed cover not available for 12mm and 18mm deep cable tray.

Stand off brackets

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Widthmm

50 CTSO050PG

75 CTSO075PG

100 CTSO100PG

150 CTSO150PG

225 CTSO225PG

300 CTSO300PG

450 CTSO450PG

600 CTSO600PG

750 CTSO750PG

900 CTSO900PG

Hanger brackets

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Widthmm

50 CTHB050/PG

75 CTHB075/PG

100 CTHB100/PG

150 CTHB150/PG

Straight divider - 3m

Finish: pre galvanised = PG, post galvanised = HDG, stainless steel grade 316 = SS

Tray depthmm

25 CTDI025PG3

50 CTDI050PG3

Earthing straps

Finish: electro-tinned

Use M6 x 12 roofing bolts Supplied in packs of 10

CT/ES100

Copper braid electro tinned 4mm2, 100mm long

Roofing bolts and nuts

Finish: BZP as standard, stainless steel grade 316 = SS

M6 x 12 roofing bolts

Supplied in packs of 100

M06X12RB

Cable tray systemsCable tray systems

99

Page 20: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

KBSI

KBS

KGI / KG

NATO

CABLE TRAYS

100

Page 21: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

101

Page 22: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

KBSI 35Cable tray with interlocking ends

Interlocking ends Alternative perforations Return flangesOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

- KBSI 35*075*0.75 35 75 0.750 3000 0.810 60 P m- KBSI 35*075*1.00 35 75 1.000 3000 1.080 60 P m- KBSI 35*100*0.75 35 100 0.750 3000 0.930 60 P m- KBSI 35*100*1.00 35 100 1.000 3000 1.240 60 P m- KBSI 35*150*0.75 35 150 0.750 3000 1.170 60 P m- KBSI 35*150*1.00 35 150 1.000 3000 1.560 60 P m- KBSI 35*200*0.75 35 200 0.750 3000 1.420 60 P m- KBSI 35*200*1.00 35 200 1.000 3000 1.890 60 P m- KBSI 35*300*0.75 35 300 0.750 3000 1.910 60 P m- KBSI 35*300*1.00 35 300 1.000 3000 2.540 60 P m

To fix with:

- KBV - - - - 0.010 96 P piece

LOAD DIAGRAM Graph valid for KBSI 35. This diagram illustrates the permissible uniformly distributed loads applied to multiple supports. They comply with IEC 61537 par 10.3.3 test type III with connection to 1/5 of the span. F = max. admissible load (daN/m) L = support distance (m) Max. deflection (m) = L/100

CHARACTERISTICS Embedded perforations for : - extra load capacity - better aeration - better stability - better condensation drainage Alternative perforations for : - better fixation on the supports - very useful for cable fixation. Earthing. TECHNICAL INFORMATION The perforation scheme differs according to the width. The surface of the interlocking end is rounded in order to protect the cables. Round holes of Ø 16 mm and Ø 19.5 mm provided as opening for the fitting of a gland.

& CLICKQUICK

102

Page 23: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

KBSI 60Cable tray with interlocking ends

Interlocking ends Alternative perforations Return flangesOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

HD KBSI 60*075*0.75 60 75 0.750 3000 1.050 60 P m- KBSI 60*075*1.00 60 75 1.000 3000 1.400 60 P m- KBSI 60*075*1.25 60 75 1.250 3000 1.750 60 P m

HD KBSI 60*100*0.75 60 100 0.750 3000 1.170 60 P mHD KBSI 60*100*1.00 60 100 1.000 3000 1.560 60 P m

- KBSI 60*100*1.25 60 100 1.250 3000 1.950 60 P mHD KBSI 60*150*0.75 60 150 0.750 3000 1.420 30 P mHD KBSI 60*150*1.00 60 150 1.000 3000 1.890 30 P m

- KBSI 60*150*1.25 60 150 1.250 3000 2.360 30 P mHD KBSI 60*200*0.75 60 200 0.750 3000 1.660 30 P mHD KBSI 60*200*1.00 60 200 1.000 3000 2.220 30 P m

- KBSI 60*200*1.25 60 200 1.250 3000 2.770 30 P mHD KBSI 60*250*0.75 60 250 0.750 3000 1.910 30 P m

- KBSI 60*250*1.00 60 250 1.000 3000 2.540 30 P mHD KBSI 60*300*0.75 60 300 0.750 3000 2.150 30 P mHD KBSI 60*300*1.00 60 300 1.000 3000 2.870 30 P m

- KBSI 60*300*1.25 60 300 1.250 3000 3.580 30 P mHD KBSI 60*400*1.00 60 400 1.000 3000 3.520 30 P m

- KBSI 60*400*1.25 60 400 1.250 3000 4.400 30 P mHD KBSI 60*500*1.00 60 500 1.000 3000 4.170 30 P m

- KBSI 60*500*1.25 60 500 1.250 3000 5.210 30 P m- KBSI 60*600*1.00 60 600 1.000 3000 4.820 30 P m- KBSI 60*600*1.25 60 600 1.250 3000 6.030 30 P m

To fix with:

- KBV - - - - 0.010 96 P piece

LOAD DIAGRAM Graph valid for KBSI 60. This diagram illustrates the permissible uniformly distributed loads applied to multiple supports. They comply with IEC 61537 par 10.3.3 test type III with connection to 1/5 of the span. F = max. admissible load (daN/m) L = support distance (m) Max. deflection (m) = L/100

More technical specifications for this product can be found at the end of this chapter.Other lengths min. 1.80 m / max. 6 m for each run of 100 mm.

& CLICKQUICK

103

Page 24: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

KBSI 60*6Cable tray with interlocking ends

Interlocking ends Alternative perforations Return flangesOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

- KBSI 60*075*1.00*6 60 75 1.000 6000 1.400 60 P m- KBSI 60*100*1.00*6 60 100 1.000 6000 1.560 60 P m- KBSI 60*150*1.00*6 60 150 1.000 6000 1.890 30 P m- KBSI 60*200*1.00*6 60 200 1.000 6000 2.220 30 P m- KBSI 60*300*1.00*6 60 300 1.000 6000 2.870 30 P m- KBSI 60*400*1.00*6 60 400 1.000 6000 3.520 30 P m

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P piece

LOAD DIAGRAM Graph valid for KBSI 60*6. This diagram illustrates the permissible uniformly distributed loads applied to multiple supports. They comply with IEC 61537 par 10.3.3 test type III with connection to 1/5 of the span. F = max. admissible load (daN/m) L = support distance (m) Max. deflection (m) = L/100

Other lengths on request : min. 1.80 m / max. 6 m per steps of 100 mm. CHARACTERISTICS Embedded perforations for : - extra load capacity - better aeration - better stability - better condensation drainage Alternative perforations for : - better fixation on the supports - very useful for cable fixation. Earthing. TECHNICAL INFORMATION The perforation scheme differs according to the width. Alternative perforation beginning at width 200 mm. The surface of the interlocking end is rounded in order to protect the cables. Round holes of Ø 16 mm and Ø 19.5 mm provided as opening for the fitting of a gland. Separation ‘SLIS 60’ can be used on any width from 200 mm.

104

Page 25: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

KBS 35Perforated cable tray

Alternative perforation Return flangesOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

HD KBS 35*050*0.75 35 50 0.750 3000 0.680 150 P mHD KBS 35*050*1.00 35 50 1.000 3000 0.920 150 P mHD KBS 35*075*0.75 35 75 0.750 3000 0.810 60 P mHD KBS 35*075*1.00 35 75 1.000 3000 1.080 60 P mHD KBS 35*100*0.75 35 100 0.750 3000 0.930 60 P mHD KBS 35*100*1.00 35 100 1.000 3000 1.240 60 P mHD KBS 35*150*0.75 35 150 0.750 3000 1.170 60 P mHD KBS 35*150*1.00 35 150 1.000 3000 1.560 60 P mHD KBS 35*200*0.75 35 200 0.750 3000 1.420 60 P mHD KBS 35*200*1.00 35 200 1.000 3000 1.890 60 P mHD KBS 35*300*0.75 35 300 0.750 3000 1.910 60 P mHD KBS 35*300*1.00 35 300 1.000 3000 2.540 60 P mHD KBS 35*400*1.00 35 400 1.000 3000 3.190 60 P m

- KBS 35*500*1.00 35 500 1.000 3000 3.840 60 P m- KBS 35*600*1.00 35 600 1.000 3000 4.500 60 P m

To fix with:

- V 35 27 180 - - 0.050 48 P pieceHD V 35*200 25 200 - - 0.040 48 P piece

LOAD DIAGRAM Graph valid for KBS 35. This diagram illustrates the permissible uniformly distributed loads applied to multiple supports. They comply with IEC 61537 par 10.3.3 test type III with connection to 1/5 of the span. F = max. admissible load (daN/m) L = support distance (m) Max. deflection (m) = L/100

CHARACTERISTICS Embedded perforations for : - extra load capacity - better aeration - better stability - better condensation drainage Alternative perforations for : - better fixation on the supports - very useful for cable fixation TECHNICAL INFORMATION The perforation scheme differs according to the width. Alternative perforation beginning at 200 mm. Round holes of Ø 16 mm and Ø 19.5 mm provided as opening for the fitting of a gland. KBS 35*050*0.75 en KBS 35*050*1.00: no knock-out facility (pre-shaped holes).

105

Page 26: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

KBS 60Perforated cable tray

Alternative perforation Return flangesOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

HD KBS 60*050*0.75 60 50 0.750 3000 0.930 60 P mHD KBS 60*050*1.00 60 50 1.000 3000 1.240 60 P mHD KBS 60*075*1.00 60 75 1.000 3000 1.400 60 P mHD KBS 60*075*1.25 60 75 1.250 3000 1.750 60 P mHD KBS 60*100*1.00 60 100 1.000 3000 1.560 60 P mHD KBS 60*100*1.25 60 100 1.250 3000 1.950 60 P mHD KBS 60*100*1.50 60 100 1.500 3000 2.350 60 P mHD KBS 60*150*1.00 60 150 1.000 3000 1.890 30 P mHD KBS 60*150*1.25 60 150 1.250 3000 2.360 30 P mHD KBS 60*150*1.50 60 150 1.500 3000 2.830 30 P mHD KBS 60*200*1.00 60 200 1.000 3000 2.220 30 P mHD KBS 60*200*1.25 60 200 1.250 3000 2.770 30 P mHD KBS 60*200*1.50 60 200 1.500 3000 3.320 30 P mHD KBS 60*250*1.00 60 250 1.000 3000 2.540 30 P mHD KBS 60*300*1.00 60 300 1.000 3000 2.870 30 P mHD KBS 60*300*1.25 60 300 1.250 3000 3.580 30 P mHD KBS 60*300*1.50 60 300 1.500 3000 4.300 30 P mHD KBS 60*400*1.00 60 400 1.000 3000 3.520 30 P mHD KBS 60*400*1.25 60 400 1.250 3000 4.400 30 P mHD KBS 60*400*1.50 60 400 1.500 3000 5.280 30 P mHD KBS 60*500*1.00 60 500 1.000 3000 4.170 30 P mHD KBS 60*500*1.25 60 500 1.250 3000 5.210 30 P mHD KBS 60*500*1.50 60 500 1.500 3000 6.250 30 P mHD KBS 60*600*1.25 60 600 1.250 3000 6.030 30 P mHD KBS 60*600*1.50 60 600 1.500 3000 7.230 30 P m

To fix with:

HD V 60*200 50 200 - - 0.080 48 P piece- V 60 52 180 - - 0.090 48 P piece

LOAD DIAGRAM Graph valid for KBS 60. This diagram illustrates the permissible uniformly distributed loads applied to multiple supports. They comply with IEC 61537 par 10.3.3. test type III with connection to 1/5 of the span. F = max. admissible load (daN/m) L = support distance (m) Max. deflection (m) = L/100

Round holes of Ø 16 mm and Ø 19.5 mm provided as opening for the fitting of a gland. KBS 60*050*0.75 and KBS 60*050*1.00: No knock-out facility (pre-shaped holes).

106

Page 27: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

KBS 85Perforated cable tray

Alternative perforation Return flangesOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

HD KBS 85*100*1.00 85 100 1.000 3000 1.890 24 P mHD KBS 85*150*1.00 85 150 1.000 3000 2.220 24 P mHD KBS 85*200*1.00 85 200 1.000 3000 2.540 24 P mHD KBS 85*300*1.00 85 300 1.000 3000 3.190 24 P mHD KBS 85*400*1.00 85 400 1.000 3000 3.840 24 P mHD KBS 85*400*1.50 85 400 1.500 3000 5.770 24 P mHD KBS 85*500*1.25 85 500 1.250 3000 5.620 24 P mHD KBS 85*500*1.50 85 500 1.500 3000 6.740 24 P mHD KBS 85*600*1.25 85 600 1.250 3000 6.430 24 P mHD KBS 85*600*1.50 85 600 1.500 3000 7.720 24 P m

To fix with:

- V 85 77 180 - - 0.130 48 P pieceHD V 85*200 75 200 - - 0.130 48 P piece

LOAD DIAGRAM Graph valid for KBS 85. This diagram illustrates the permissible uniformly distributed loads applied to multiple supports. They comply with IEC 61537 par 10.3.3 test type III with connection to 1/5 of the span. F = max. admissible load (daN/m) L = support distance (m) Max. deflection (m) = L/100

CHARACTERISTICS Embedded perforations for : - extra load capacity - better aeration - better stability - better condensation drainage Alternative perforations for : - better fixation on the supports - very useful for cable fixation TECHNICAL INFORMATION The perforation scheme differs according to the width. Alternative perforation beginning at 200 mm. Round holes of Ø 16 mm and Ø 19.5 mm provided as opening for the fitting of a gland.

107

Page 28: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

KBS 110Perforated cable tray

Alternative perforation Return flangesOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

HD KBS 110*150*1.25 110 150 1.250 3000 3.180 24 P mHD KBS 110*200*1.25 110 200 1.250 3000 3.580 24 P mHD KBS 110*300*1.25 110 300 1.250 3000 4.400 24 P mHD KBS 110*400*1.25 110 400 1.250 3000 5.210 24 P mHD KBS 110*500*1.25 110 500 1.250 3000 6.030 24 P mHD KBS 110*500*1.50 110 500 1.500 3000 7.230 24 P mHD KBS 110*600*1.25 110 600 1.250 3000 6.840 24 P mHD KBS 110*600*1.50 110 600 1.500 3000 8.210 24 P m

To fix with:

HD V 110*200 100 200 - - 0.170 48 P piece

LOAD DIAGRAM Graph valid for KBS 110. This diagram illustrates the permissible uniformly distributed loads applied to multiple supports. They comply with IEC 61537 par 10.3.3 test type III with connection to 1/5 of the span. F = max. admissible load (daN/m) L = support distance (m) Max. deflection (m) = L/100

CHARACTERISTICS Embedded perforations for : - extra load capacity - better aeration - better stability - better condensation drainage Alternative perforations for : - better fixation on the supports - very useful for cable fixation TECHNICAL INFORMATION The perforation scheme differs according to the width. Alternative perforation beginning at 200 mm. Round holes of Ø 16 mm and Ø 19.5 mm provided as opening for the fitting of a gland.

108

Page 29: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

KBS 110*6Perforated cable tray

Alternative perforation Return flanges Support distance up to 6 meterOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

HD KBS 110*200*1.50*6 110 200 1.500 6000 4.300 24 P mHD KBS 110*300*1.50*6 110 300 1.500 6000 5.280 24 P mHD KBS 110*400*1.50*6 110 400 1.500 6000 6.250 24 P mHD KBS 110*500*1.50*6 110 500 1.500 6000 7.230 24 P mHD KBS 110*600*1.50*6 110 600 1.500 6000 8.210 24 P m

To fix with:

HD KPW 115 400 - - 0.590 24 P piece

LOAD DIAGRAM Graph valid for KBS 110*6. This diagram illustrates the permissible uniformly distributed loads applied to multiple supports. They comply with IEC 61537 par 10.3.3 test type III . F = max. admissible load (daN/m) L = support distance (m) Max. deflection (m) = L/200

CHARACTERISTICS Embedded perforations for : - extra load capacity - better aeration - better stability - better condensation drainage Alternative perforations for : - better fixation on the supports - very useful for cable fixation TECHNICAL INFORMATION The perforation scheme differs according to the width. Alternative perforation beginning at 200 mm. Round holes of Ø 16 mm and Ø 19.5 mm provided as opening for the fitting of a gland.

109

Page 30: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

KBSM(I)Cable tray machine constr. interl. ends

Alternative perforation Return flangesOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

- KBSM 60*050*1.00 60 50 1.000 3000 1.240 3 P m- KBSMI 60*075*1.00 60 75 1.000 3000 1.400 3 P m- KBSMI 60*100*1.00 60 100 1.000 3000 1.560 3 P m- KBSMI 60*150*1.00 60 150 1.000 3000 1.890 3 P m- KBSMI 60*200*1.00 60 200 1.000 3000 2.200 3 P m- KBSMI 60*300*1.00 60 300 1.000 3000 2.870 3 P m

- Cable tray machine constructions, interlocking from width 75 mm (connect width 50 mm with jointing plate) - Large cable outlet (dimensions 30x50 mm) with round corners - Distance between cable outlets: bottom = 150 mm, sides = 300 mm - Edge protection RBKBSM to order separately - Round cable gland central to the bottom, alternately M16/M20 - The cable outlet holes allow the cable trays to be used in machine constructions, especially in the field of internal transport - Can be used as lighting rail by immediately connecting through bottom perforations M16 and M20 - Staggered slots in sides and bottom for easy connection with accessories - To be used with standard accessories, such as the cover with swerve clamp

KGI 60Cable tray not perforated, interlocking

Not perforated Return flangesOn Demand Height 35 mm On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

HD KGI 60*075*1.00 60 75 1.000 3000 1.700 3 P mHD KGI 60*100*1.00 60 100 1.000 3000 1.900 3 P mHD KGI 60*150*1.00 60 150 1.000 3000 2.300 3 P mHD KGI 60*200*1.00 60 200 1.000 3000 2.700 3 P mHD KGI 60*250*1.00 60 250 1.000 3000 3.100 3 P mHD KGI 60*300*1.00 60 300 1.000 3000 3.500 3 P m

- KGI 60*300*1.25 60 300 1.250 3000 4.300 3 P mHD KGI 60*400*1.00 60 400 1.000 3000 4.300 3 P m

- KGI 60*400*1.25 60 400 1.250 3000 5.300 3 P m- KGI 60*500*1.25 60 500 1.250 3000 6.300 3 P m- KGI 60*600*1.25 60 600 1.250 3000 7.300 3 P m

To fix with:

- KBV - - - - 0.010 96 P piece

& CLICKQUICK

110

Page 31: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

LOAD DIAGRAM Graph valid for KGI 60. This diagram illustrates the permissible uniformly distributed loads applied to multiple supports. They comply with IEC 61537 par 10.3.3 test type III with connection to 1/5 of the span. F = max. admissible load (daN/m) L = support distance (m) Max. deflection (m) = L/100

KG 110Cable tray not perforated

Not perforated Return flangesOn Demand Height 85 mm On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

HD KG 110*100*1.50 110 100 1.500 3000 4.000 18 P mHD KG 110*150*1.50 110 150 1.500 3000 4.590 18 P mHD KG 110*200*1.50 110 200 1.500 3000 5.180 18 P mHD KG 110*300*1.50 110 300 1.500 3000 6.360 18 P mHD KG 110*400*1.50 110 400 1.500 3000 7.540 18 P mHD KG 110*500*1.50 110 500 1.500 3000 8.710 18 P mHD KG 110*600*1.50 110 600 1.500 3000 9.890 18 P m

To fix with:

HD V 110*200 100 200 - - 0.170 48 P piece

LOAD DIAGRAM Graph valid for KG 110. This diagram illustrates the permissible uniformly distributed loads applied to multiple supports. They comply with IEC 61537 par 10.3.3 test type III with connection to 1/5 of the span. F = max. admissible load (daN/m) L = support distance (m) Max. deflection (m) = L/100

111

Page 32: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

NATO 15Perforated cable tray - upright flanges

Linear and alternative perforations Upright flangesOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

HD NATO 15*050*1.25 15 50 1.250 2000 0.730 40 P mHD NATO 15*100*1.25 15 100 1.250 2000 1.050 20 P mHD NATO 15*150*1.25 15 150 1.250 2000 1.350 20 P mHD NATO 15*200*1.25 15 200 1.250 2000 1.700 20 P mHD NATO 15*300*1.25 15 300 1.250 2000 2.400 20 P m

To fix with:

HD V 15*200 20 150 - - 0.050 48 P piece

LOAD DIAGRAM Graph valid for NATO 15, mounted in continuous span with the jointing plates 1/5 away from the supports. Safety factor = 2. F = max. admissible load (daN/m) L = support distance (m) L/200 = deflection (m)

DUniversal cover

Especially used for horizontal en vertical sectionsOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

HD D 050 10 50 - 3000 0.350 3 P mHD D 075 10 75 - 2000 0.500 10 P mHD D 100 10 100 - 2000 0.820 10 P mHD D 150 10 150 - 2000 1.170 10 P mHD D 200 10 200 - 2000 1.420 10 P mHD D 250 10 250 - 2000 1.850 10 P mHD D 300 10 300 - 2000 2.100 10 P mHD D 400 10 400 - 2000 4.150 10 P mHD D 500 10 500 - 2000 5.000 10 P mHD D 600 10 600 - 2000 5.650 10 P m

To fix with:

- DCO - - - - 0.010 96 P piece- DCL - - - - 0.010 96 P piece

Covers with width > 400 mm are delivered with diagonal reinforcements.

112

Page 33: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

DCOLid clamp

Standard finish Spring steel

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

- DCO - - - - 0.010 96 P piece

2 pieces per meter.

DCLLid clamp clips

Standard finish Stainless Steel 316

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

- DCL - - - - 0.010 96 P piece

2 pieces per meter. Not applicable for KG.

& CLICKQUICK

& CLICKQUICK

113

Page 34: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

B 90Horizontal bend 90°

Slides over the cable traysRadius 100 mmOn Demand Height 35mm - 85mm - 110mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

W 50 75 100 150 200 250 300 400 500 600A 255 280 305 355 405 455 505 605 705 805B 255 280 305 355 405 455 505 605 705 805

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD B 90*60*050 60 50 - - 0.480 1 P pieceHD B 90*60*075 60 75 - - 0.520 1 P pieceHD B 90*60*100 60 100 - - 0.740 1 P pieceHD B 90*60*150 60 150 - - 0.830 1 P pieceHD B 90*60*200 60 200 - - 1.380 1 P pieceHD B 90*60*250 60 250 - - 1.860 1 P pieceHD B 90*60*300 60 300 - - 2.300 1 P pieceHD B 90*60*400 60 400 - - 2.960 1 P pieceHD B 90*60*500 60 500 - - 5.430 1 P pieceHD B 90*60*600 60 600 - - 6.690 1 P piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

More technical specifications for this product can be found at the end of this chapter.Minimum number bolts and nuts VM 6*10: 8 pieces.

114

Page 35: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

DB 90Cover for horizontal bend 90°

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

50 75 100 150 200 250 300 400 500 600B 256 281 306 356 406 456 506 606 706 806

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD DB 90*050 10 56 - - 0.520 1 P pieceHD DB 90*075 10 81 - - 0.620 1 P pieceHD DB 90*100 10 106 - - 0.730 1 P pieceHD DB 90*150 10 156 - - 0.980 1 P pieceHD DB 90*200 10 206 - - 1.260 1 P pieceHD DB 90*250 10 256 - - 1.590 1 P pieceHD DB 90*300 10 306 - - 1.950 1 P pieceHD DB 90*400 10 406 - - 2.780 1 P pieceHD DB 90*500 10 506 - - 3.750 1 P pieceHD DB 90*600 10 606 - - 4.880 1 P piece

To fix with:

- DCL - - - - 0.010 96 P piece

VHAdjustable Corner 90-180°

Corner plate adjustable between 90° and 180°On Demand Height 35 mm - 85 mm - 110 mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD VH 60*050 60 50 - - 0.350 1 P pieceHD VH 60*075 60 75 - - 0.350 1 P pieceHD VH 60*100 60 100 - - 0.400 1 P pieceHD VH 60*150 60 150 - - 0.500 1 P pieceHD VH 60*200 60 200 - - 0.700 1 P pieceHD VH 60*250 60 250 - - 0.900 1 P pieceHD VH 60*300 60 300 - - 1.150 1 P pieceHD VH 60*400 60 400 - - 1.700 1 P pieceHD VH 60*500 60 500 - - 2.500 1 P pieceHD VH 60*600 60 600 - - 3.450 1 P piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

Minimum number bolts and nuts VM 6*10: 4 pieces.

115

Page 36: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

THorizontal T-piece

Slides over the cable traysRadius 100 mmOn Demand Height 35 mm - 85 mm - 110 mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

50 75 100 150 200 250 300 400 500 600A 458 483 508 558 608 658 708 808 908 1008

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD T 60*050 60 50 - - 0.840 1 P pieceHD T 60*075 60 75 - - 0.980 1 P pieceHD T 60*100 60 100 - - 1.130 1 P pieceHD T 60*150 60 150 - - 1.520 1 P pieceHD T 60*200 60 200 - - 1.760 1 P pieceHD T 60*250 60 250 - - 2.250 1 P pieceHD T 60*300 60 300 - - 2.590 1 P pieceHD T 60*400 60 400 - - 3.380 1 P pieceHD T 60*500 60 500 - - 6.120 1 P pieceHD T 60*600 60 600 - - 7.260 1 P piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

Minimum number bolts and nuts VM 6*10: 12 pieces.

DTCover for horizontal T-piece

For all heightsOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD DT 050 10 56 - - 0.990 1 P pieceHD DT 075 10 81 - - 1.140 1 P pieceHD DT 100 10 106 - - 1.310 1 P pieceHD DT 150 10 156 - - 1.660 1 P pieceHD DT 200 10 206 - - 2.060 1 P pieceHD DT 250 10 256 - - 1.780 1 P pieceHD DT 300 10 306 - - 2.980 1 P pieceHD DT 400 10 406 - - 4.050 1 P pieceHD DT 500 10 506 - - 5.320 1 P pieceHD DT 600 10 606 - - 6.710 1 P piece

To fix with:

- DCL - - - - 0.010 96 P piece

116

Page 37: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

ASHorizontal adapter 90°

Slides over the cable traysRadius 100 mmOn Demand Height 35 mm - 85 mm - 110 mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

50 75 100 150 200 250 300 400 500 600A 458 483 508 558 608 658 708 808 908 1008

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD AS 60*050 60 50 - - 0.580 1 P pieceHD AS 60*075 60 75 - - 0.620 1 P pieceHD AS 60*100 60 100 - - 0.680 1 P pieceHD AS 60*150 60 150 - - 0.710 1 P pieceHD AS 60*200 60 200 - - 0.810 1 P pieceHD AS 60*250 60 250 - - 0.910 1 P pieceHD AS 60*300 60 300 - - 0.930 1 P pieceHD AS 60*400 60 400 - - 1.130 1 P pieceHD AS 60*500 60 500 - - 1.530 1 P pieceHD AS 60*600 60 600 - - 1.780 1 P piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

Minimum number bolts and nuts VM 6*10: 8 pieces.

DASCover for horizontal adapter 90°

For all heightsOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD DAS 050 10 56 - - 0.820 1 P pieceHD DAS 075 10 81 - - 0.870 1 P pieceHD DAS 100 10 106 - - 0.910 1 P pieceHD DAS 150 10 156 - - 1.010 1 P pieceHD DAS 200 10 206 - - 1.090 1 P pieceHD DAS 250 10 256 - - 0.550 1 P pieceHD DAS 300 10 306 - - 1.270 1 P pieceHD DAS 400 10 406 - - 1.450 1 P pieceHD DAS 500 10 506 - - 1.630 1 P pieceHD DAS 600 10 606 - - 1.810 1 P piece

To fix with:

- DCL - - - - 0.010 96 P piece

117

Page 38: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

KRCross-over

Slides over the cable traysRadius 100 mmOn Demand Height 35 mm - 85 mm - 110 mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD KR 60*050 60 50 - - 1.180 1 P pieceHD KR 60*075 60 75 - - 1.560 1 P pieceHD KR 60*100 60 100 - - 1.480 1 P pieceHD KR 60*150 60 150 - - 2.080 1 P pieceHD KR 60*200 60 200 - - 2.380 1 P pieceHD KR 60*250 60 250 - - 2.760 1 P pieceHD KR 60*300 60 300 - - 3.520 1 P pieceHD KR 60*400 60 400 - - 4.610 1 P pieceHD KR 60*500 60 500 - - 5.320 1 P pieceHD KR 60*600 60 600 - - 6.160 1 P piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

Minimum number bolts and nuts VM 6*10: 16 pieces.

DKRCover for cross-over

For all heightsOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD DKR 050 10 56 - - 0.450 1 P pieceHD DKR 075 10 81 - - 0.700 1 P pieceHD DKR 100 10 106 - - 0.770 1 P pieceHD DKR 150 10 156 - - 1.160 1 P pieceHD DKR 200 10 206 - - 1.590 1 P pieceHD DKR 250 10 256 - - 2.020 1 P pieceHD DKR 300 10 306 - - 2.480 1 P pieceHD DKR 400 10 406 - - 5.000 1 P pieceHD DKR 500 10 506 - - 6.700 1 P pieceHD DKR 600 10 606 - - 8.300 1 P piece

To fix with:

- DCL - - - - 0.010 96 P piece

118

Page 39: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

SB 90Rising elbow 90°

Slides over the cable traysRadius 100 mmOn Demand Height 35 mm - 85 mm - 110 mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD SB 90*60*050 60 50 - - 0.550 1 P pieceHD SB 90*60*075 60 75 - - 0.650 1 P pieceHD SB 90*60*100 60 100 - - 0.730 1 P pieceHD SB 90*60*150 60 150 - - 0.880 1 P pieceHD SB 90*60*200 60 200 - - 1.000 1 P pieceHD SB 90*60*250 60 250 - - 1.080 1 P pieceHD SB 90*60*300 60 300 - - 1.180 1 P pieceHD SB 90*60*400 60 400 - - 1.430 1 P pieceHD SB 90*60*500 60 500 - - 1.900 1 P pieceHD SB 90*60*600 60 600 - - 2.150 1 P piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

Minimum number bolts and nuts VM 6*10: 8 pieces.

SBCLSnap-in internal rising bend 90°

Snap-in system with cable tray KBS 60 and KBSI 60Radius 100 mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

- SBCL 90*60*050 60 50 - - 0.550 1 P piece- SBCL 90*60*075 60 75 - - 0.650 1 P piece- SBCL 90*60*100 60 100 - - 0.730 1 P piece- SBCL 90*60*150 60 150 - - 0.880 1 P piece- SBCL 90*60*200 60 200 - - 1.000 1 P piece- SBCL 90*60*250 60 250 - - 1.080 1 P piece- SBCL 90*60*300 60 300 - - 1.180 1 P piece- SBCL 90*60*400 60 400 - - 1.430 1 P piece- SBCL 90*60*500 60 500 - - 1.900 1 P piece- SBCL 90*60*600 60 600 - - 2.150 1 P piece

- opening for extra locking using 4x VM 6*10 - openings provided for fitting a lid - Only available in height 60 mm.

& CLICKQUICK

119

Page 40: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

DSB 90Cover for rising elbow 90°

Flat banded.On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD DSB 90*050 - 50 - - 0.150 1 P pieceHD DSB 90*075 - 75 - - 0.190 1 P pieceHD DSB 90*100 - 100 - - 0.260 1 P pieceHD DSB 90*150 - 150 - - 0.390 1 P pieceHD DSB 90*200 - 200 - - 0.510 1 P pieceHD DSB 90*250 - 250 - - 0.640 1 P pieceHD DSB 90*300 - 300 - - 0.770 1 P pieceHD DSB 90*400 - 400 - - 1.030 1 P pieceHD DSB 90*500 - 500 - - 1.290 1 P pieceHD DSB 90*600 - 600 - - 1.540 1 P piece

To fix with:

- DCL - - - - 0.010 96 P piece

VB 90Low elbow 90°

Slides over the cable traysRadius 100 mmOn Demand Height 35 mm - 85 mm - 110 mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD VB 90*60*050 60 50 - - 0.550 1 P pieceHD VB 90*60*075 60 75 - - 0.630 1 P pieceHD VB 90*60*100 60 100 - - 0.650 1 P pieceHD VB 90*60*150 60 150 - - 0.780 1 P pieceHD VB 90*60*200 60 200 - - 0.850 1 P pieceHD VB 90*60*250 60 250 - - 0.950 1 P pieceHD VB 90*60*300 60 300 - - 1.080 1 P pieceHD VB 90*60*400 60 400 - - 1.330 1 P pieceHD VB 90*60*500 60 500 - - 1.430 1 P pieceHD VB 90*60*600 60 600 - - 1.600 1 P piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

Minimum number bolts and nuts VM 6*10: 8 pieces.

120

Page 41: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

VBCLSnap-in external rising bend

Snap-in system with cable tray KBS 60 and KBSI 60Radius 100 mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

- VBCL 90*60*050 60 50 - - 0.550 1 P piece- VBCL 90*60*075 60 75 - - 0.630 1 P piece- VBCL 90*60*100 60 100 - - 0.650 1 P piece- VBCL 90*60*150 60 150 - - 0.780 1 P piece- VBCL 90*60*200 60 200 - - 0.850 1 P piece- VBCL 90*60*250 60 250 - - 0.950 1 P piece- VBCL 90*60*300 60 300 - - 1.080 1 P piece- VBCL 90*60*400 60 400 - - 1.330 1 P piece- VBCL 90*60*500 60 500 - - 1.430 1 P piece- VBCL 90*60*600 60 600 - - 1.600 1 P piece

- opening for extra locking using 4x VM 6*10 - openings provided for fitting a lid. - Only available in height 60 mm.

DVB 90Cover for low elbow 90°

Flat bandedOn Demand Height of 35 mm - 85 mm - 110 mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD DVB 90*60*050 - 50 - - 0.150 1 P pieceHD DVB 90*60*075 - 75 - - 0.250 1 P pieceHD DVB 90*60*100 - 100 - - 0.340 1 P pieceHD DVB 90*60*150 - 150 - - 0.510 1 P pieceHD DVB 90*60*200 - 200 - - 0.680 1 P pieceHD DVB 90*60*250 - 250 - - 0.850 1 P pieceHD DVB 90*60*300 - 300 - - 1.020 1 P pieceHD DVB 90*60*400 - 400 - - 1.360 1 P pieceHD DVB 90*60*500 - 500 - - 1.710 1 P pieceHD DVB 90*60*600 - 600 - - 2.040 1 P piece

To fix with:

- DCL - - - - 0.010 96 P piece

& CLICKQUICK

121

Page 42: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

SDBHinged joint double

On Demand Height 35 mm - 85 mm - 110 mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD SDB 60*050 60 50 - - 0.940 1 pieceHD SDB 60*075 60 75 - - 0.980 1 pieceHD SDB 60*100 60 100 - - 1.030 1 pieceHD SDB 60*150 60 150 - - 1.120 1 pieceHD SDB 60*200 60 200 - - 1.220 1 pieceHD SDB 60*250 60 250 - - 1.310 1 pieceHD SDB 60*300 60 300 - - 1.420 1 pieceHD SDB 60*400 60 400 - - 1.590 1 pieceHD SDB 60*500 60 500 - - 1.780 1 pieceHD SDB 60*600 60 600 - - 1.970 1 piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

Minimum number bolts and nuts VM 6*10: 8 pieces.

DSHinged joint

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD DS 35 35 - - - 0.110 24 pieceHD DS 60 60 - - - 0.130 50 P pieceHD DS 85 85 - - - 0.340 24 pieceHD DS 110 110 - - - 0.390 24 piece

Minimum number bolts and nuts VM 6*10: 4 pieces.

122

Page 43: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

AZHUniversal coupling 90°

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD AZH 35 35 - - - 0.340 1 pieceHD AZH 60 60 - - - 0.390 1 P pieceHD AZH 85 85 - - - 0.750 1 pieceHD AZH 110 110 - - - 0.900 1 piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

Minimum number bolts and nuts VM 6*10: 4 pieces.

BVSIStiffening plate

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD BVSI 050 46.6 100 - - 0.080 1 P pieceHD BVSI 075 70 100 - - 0.100 1 P pieceHD BVSI 100 75 100 - - 0.100 1 P pieceHD BVSI 150 125 100 - - 0.160 1 P pieceHD BVSI 200 175 100 - - 0.180 1 P pieceHD BVSI 250 225 100 - - 0.300 1 P pieceHD BVSI 300 275 100 - - 0.370 1 P pieceHD BVSI 400 375 100 - - 0.500 1 P pieceHD BVSI 500 475 100 - - 0.520 1 P pieceHD BVSI 600 575 100 - - 0.750 1 P piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

Minimum number bolts and nuts VM 6*10: 4 pieces.

123

Page 44: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

VSReducting plate

On Demand Height 35 mm - 85 mm - 110 mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD VS 60*025 50 25 - - 0.080 1 P pieceHD VS 60*050 50 50 - - 0.080 1 P pieceHD VS 60*075 50 75 - - 0.090 1 P pieceHD VS 60*100 50 100 - - 0.100 1 P pieceHD VS 60*125 50 125 - - 0.100 1 P pieceHD VS 60*150 50 150 - - 0.110 1 P pieceHD VS 60*200 50 200 - - 0.120 1 P pieceHD VS 60*250 50 250 - - 0.140 1 P pieceHD VS 60*300 50 300 - - 0.180 1 P pieceHD VS 60*350 50 350 - - 0.180 1 P pieceHD VS 60*400 50 400 - - 0.210 1 P piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

More technical specifications for this product can be found at the end of this chapter.Minimum number bolts and nuts VM 6*10: 4 pieces.

EEnd piece

On Demand Height 35 mm - 85 mm - 110 mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD E 60*050 55 46 - - 0.110 1 P pieceHD E 60*075 55 71 - - 0.120 1 P pieceHD E 60*100 55 96 - - 0.130 1 P pieceHD E 60*150 55 146 - - 0.160 1 P pieceHD E 60*200 55 196 - - 0.180 1 P pieceHD E 60*250 55 246 - - 0.170 1 P pieceHD E 60*300 55 296 - - 0.220 1 P pieceHD E 60*400 55 396 - - 0.270 1 P pieceHD E 60*500 55 496 - - 0.310 1 P pieceHD E 60*600 55 596 - - 0.360 1 P piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

Minimum number bolts and nuts VM 6*10: 4 pieces.

124

Page 45: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

RBKBSMEdge protection KBSM(I)

Standard finish Polypropylene

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

- RBKBSM - - - - 0.010 - P piece

MPFolded mounting plate

For the fixation of contact and distribution boxesOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD MP 157 160 - - 0.180 50 P piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

Number bolts and nuts VM 6*10: 2 pieces.

MPVFlat mounting plate

For the fixation of contact and distribution boxesOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD MPV 175 160 - - 0.200 50 P piece

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P piece- KBV - - - - 0.010 96 P piece

HD VMK 6*10 - - M6 - 0.010 250 P piece

Number bolts and nuts VM 6*10: 2 pieces.

125

Page 46: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

MPVCLMounting plate clips

For the fixation of contact and distribution boxes.On Demand Powder coating / Duplex SystemStandard finish Pre-galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

- MPVCL 175 160 - - 0.180 50 P piece

Clippable on the perforated cable tray with clip KBV.

SLOSDivision plate free

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

HD SLOS 35 35 - - 3000 0.330 150 P mHD SLOS 60 60 - - 3000 0.510 120 P mHD SLOS 85 85 - - 3000 0.680 60 P mHD SLOS 110 110 - - 3000 0.820 3 P m

To fix with:

HD VM 6*10 - - M6 10 0.010 250 P pieceHD VMK 6*10 - - M6 - 0.010 250 P piece

Fixation set VM 6*10: 1 per meter.

SLISClip-in partition

Standard finish Pre-galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

- SLIS 60 60 - - 3000 0.440 3 P m

To fix with:

- CL - - - - 0.010 100 P piece

Fixation set clips CL : 4 pieces per length. Separation SLIS can be used on any width from 200 mm.

& CLICKQUICK

& CLICKQUICK

126

Page 47: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

CLClips for clip-in partition

Standard finish Pre-galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

- CL - - - - 0.010 100 P piece

4 pieces per length

SINBuild-in division plate

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

HD SIN 85 85 - - 3000 0.670 3 mHD SIN 110 110 - - 3000 0.900 3 m

This partition is pointwelded in the cable tray KG/KGI according to your specifications. The scale should be given when ordering.

SINIBuild-in division plate KGI

On Demand Height 35 mmOn Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/m u Stock Unit

HD SINI 60 60 - - 2950 0.510 3 m

This partition is pointwelded in the cable tray KG according to your specifications. The scale should be given when ordering.

& CLICKQUICK

127

Page 48: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

V 35Jointing plate for fast mounting

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

- V 35 27 180 - - 0.050 48 P piece

Minimum number bolts and nuts VM 6*10: 1 pieces.

V 60Jointing plate for fast mounting

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

- V 60 52 180 - - 0.090 48 P piece

Minimum number bolts and nuts VM 6*10: 2 pieces.

V 85Jointing plate for fast mounting

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

- V 85 77 180 - - 0.130 48 P piece

Minimum number bolts and nuts VM 6*10: 2 pieces.

128

Page 49: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

V 15*200Jointing plate

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD V 15*200 20 150 - - 0.050 48 P piece

V 35*200Jointing plate

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD V 35*200 25 200 - - 0.040 48 P piece

Minimum number bolts and nuts VM 6*10: 2 pieces.

V 60*200Jointing plate

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD V 60*200 50 200 - - 0.080 48 P piece

Minimum number bolts and nuts VM 6*10: 4 pieces.

129

Page 50: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

V 85*200Jointing plate

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD V 85*200 75 200 - - 0.130 48 P piece

Minimum number bolts and nuts VM 6*10: 4 pieces.

V 110*200Jointing plate

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD V 110*200 100 200 - - 0.170 48 P piece

Minimum number bolts and nuts VM 6*10: 8 pieces.

KPWJointing plate for wide-span

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD KPW 115 400 - - 0.590 24 P piece

Minimum number bolts and nuts VM 6*10: 8 pieces.

130

Page 51: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

CABLE TRAYS

LVSupporting corner

On Demand Powder coating / Duplex SystemStandard finish Pre-galvanisedOptional finish 1 Hot-dip galvanised

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

HD LV 35 32 20 - - 0.080 24 pieceHD LV 60*85 60 43 - - 0.170 24 P pieceHD LV 110 94 58 - - 0.240 24 piece

Minimum number bolts and nuts VM 6*10: 4 pieces.

KBVFast locking for KBSI

Standard finish Stainless Steel 316

HD ReferenceC

mmN mm

KœL mm

2 mm kg/piece u Stock Unit

- KBV - - - - 0.010 96 P piece

& CLICKQUICK

131

Page 52: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

TECHNICAL INFORMATION

KBSI 60Mounting principle

How do you proceed ? Very simple : 1. Put two lengths together. 2. Slide them into each other. 3. Fix clips KBV for extra stability and safe locking. 4. Finished !!! This system offers you various advantages : 1. Smaller cost price. 2. Faster mounting. 3. No bolts and nuts required. 4. Fixation with clips. 5. Earthing. 6. Easier fixation thanks to alternative perforations. 7. Better stability thanks to embedded perforations. 8. Better aeration of the cables thanks to embedded perforations. 9. Integrated cable protection thanks to overlapping ends. 10. Smooth finishing touch. 11. Smaller stock investment.

B 90Mounting principle

132

Page 53: Cable Tray - stalutech.nlstalutech.nl/wp-content/uploads/2013/10/H-06.pdf · 33 Cable tray systems Cable tray systems Cable tray systems 32 The comprehensive Metsec cable tray range

TECHNICAL INFORMATION

VSMounting principle

133


Recommended