KP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 54 CABLE TRAY SYSTEM GFK
Transcript
Page 1: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

KPKPKPKPCable trays

Dividers

Fittings

Covers

Accessoires

Cable tray systems available in height 50 80 110

KPSystemSystem

KPKPKPKPKP54

CABLE TRAY SYSTEM GFK

Page 2: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

The cable tray system KP EBO Systems (manufactured by pultrusion) provides maximum fl exibility

and effi ciency and a support distance of up to 4 m.

Its quickly assembly with clip in jointing pieces without screws included automatically an expansion

joint, greatly facilitates its installation.

Covers

Accessoires

55

Page 3: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

Available siderail heights

GRP-Cable tray, pultruded, perfored KPL 58 58 62

GRP-Cable tray, pultruded, no-perfored KP 58 58 62

GRP-Encap, pultruded KPKE 59 59 63

GRP-Splice plate, pultruded, horizontal KPGH... 59 59 63

STAINLESS STEEL-Splice plate, horizontal KPIH 59 ––––– –––––

GRP-Divider, pultruded KPT... ––––– 59 63

GRP-T, pultruded, small radius KPSS ––––– 59 –––––

GRP-T, pultruded, big radius KPST ––––– ––––– 63

GRP-Elbow 45°, pressed, horizontal KPC ––––– 60 63

GRP-Elbow 90°, pressed, big radius KPB ––––– 60 64

GRP-Changing elevation, pressed KPET ––––– 60 64

GRP-Exterior changing elevation, pressed KPBI ––––– 60 64

GRP-Interior changing elevation, pressed KPBA ––––– 61 64

Cover clip DF... 69

Cover fi xing insert DF M 69*

Cover clip DFUB 69*

Rack, pressed KR 70*

Separating stud TB 70*

Dome head bolt FKM 70*

Hexagon head bolt SKM 70*

Covers for cables ladders UL systems are available from page 66.

SYSTEM

ACCESSORIES

* suitable for all heights

50 80 40

805040

805040

805040

805040

805040

805040

805040

805040

805040

805040

805040

805040

805040

NEW

56

CABLE TRAY SYSTEM KP

Page 4: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

KPL...

KP...

KPKE...

KPB...

KPBA...

KPST...

KPT...

KPD...

KPET...

KPBI...

57

Page 5: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

58

CABLE TRAY SYSTEM KP

GRP cable trayspultruded, perforated

L = fixing distance (m)

Load

q (k

N/m

)

Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5 from thesupport. If this distance is not respected, it is necessary to raise the deflection values by approx. 30%.

The splice plates KPGH 50/ KPIH 50 V4A are not included in the cables trays, please order themseparately.

Load diagram : q = load evenly distributed cables (according to DIN EN IEC 61537 standard)

KPL 40.060

7032 40 60 2,0KPL 50.100 7032 50 100 2,5KPL 50.150 7032 50 150 2,5KPL 50.200 7032 50 200 2,5KPL 40.060/6 7032 40 60 2,0KPL 50.100/6 7032 50 100 2,5KPL 50.150/6 7032 50 150 2,5KPL 50.200/6 7032 50 200 2,5

K23

K23K23K23K23K23K23K23

Item ref. RAL colour

Height WidthB

Materialthickness

(th)mm mm mm

Min. pack.

3 m3 m3 m3 m6 m6 m6 m6 m

EANcode

952557952564952571952588952632952649952656952663

Weight 100 units

pc m/

60,0104,1130,0166,060,0

104,1130,0166,0

Due to the expansion of the material, the following points during installation must be observed :The supporting systems must not be fixed close to the splice platesFor fixing the cables trays on brackets, you need to drill a 9 mm diameter hole for the fixing of thecable tray base with bolts M6x20 V4AWhen fixing the splice plates KPGH… and KPIH..., an expansion distance of about 3 mm must beconsidered.

GRP cable trayspultruded, not perforated

The splice plates KPGH 50/ KPIH 50 V4A are not included in the cables trays, please order themseparately.

KP 40.060

7032 40 60 2,0KP 50.100 7032 50 100 2,5KP 50.150 7032 50 150 2,5KP 50.200 7032 50 200 2,5KP 40.060/6 7032 40 60 2,0KP 50.100/6 7032 50 100 2,5KP 50.150/6 7032 50 150 2,5KP 50.200/6 7032 50 200 2,5

K23

K23K23K23K23K23K23K23

Item ref. RAL colour

Height WidthB

Materialthickness

(th)mm mm mm

Min. pack.

3 m3 m3 m3 m6 m6 m6 m6 m

EANcode

967612952403952410952427952472952489952496952502

Weight 100 units

pc m/

6210013116260

100131162

Due to the expansion of the material, the following points during installation must be observed :The supporting systems must not be fixed close to the splice platesFor fixing the cables trays on brackets, you need to drill a 9 mm diameter hole for the fixing of thecable tray base with bolts M6x20 V4AWhen fixing the splice plates KPGH… and KPIH..., an expansion distance of about 3 mm must beconsidered.

Page 6: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

59

End cap for cable traypultruded

for the cable tray ends

Used for: Cable tray H50, H80, KP…, KPL… and cable truncking LFG…

Mounting accessories required : 2 bolts M6x16 V4A ( to be ordered separately )

KPKE 40.060

7032 40 60KPKE 50.100 7032 50 100KPKE 50.150 7032 50 150KPKE 50.200 7032 50 200

K23

K23K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.1 p.

EANcode

955381955398955404955411

Weight 100 units

pc

5,56,09,0

10,0

Clipsable splice platepressed, horizontal, fixing with bolts

for the connection of cable trays and fittings H40, with splice plates H40

Mounting accessories required : 2 bolts M6x20 V4A ( to be ordered separately )

KPGH 40

7032 25K23

Item ref. RAL colour

Height

mm

Min. pack.

1 set

EANcode

955695

Weight 100 units

4,5

During the assembly, an expansion gap of 3 mm for dilatation must be considered.

Clipsable splice platepultruded, horizontal

for the connection of cable trays and fittings H50, with splice plates H50During the assembly, an expansion gap of 3 mm is automatically taken in consideration.

KPGH 50

7032 39K23

Item ref. RAL colour

Height

mm

Min. pack.

1 set

EANcode

955701

Weight 100 units

6

Splice platehorizontal, stainless steel

Mounting accessories required : 2 bolts M6x20 V4A ( to be ordered separately )

KPIH 40 E5

40E5

Item ref. Height

mm

Min. pack.

1 set

EANcode

955688

Weight 100 units

2,3

During the assembly, an expansion gap of 3 mm for dilatation must be considered.

Separatorpultruded

The divider KPT50 is delivered not mounted, it can be fixed in the cable tray with a boltM 6x16V4A each meter.The divider KPT50/M could be delivered pre-installed (riveted), the position inside the cabletray should be defined with the order.

to separate cables with different functions and / or to separate voltages

KPT 50

7032 37KPT 50/M 7032 37

K23

K23

Item ref. RAL colour

Height

mm

Min. pack.

3 m3 m

EANcode

953127953141

Weight 100 units

m

3636

GRP tee junction, small radiuspressed, with interlocking coupler

KPSS 50.100/P

7032 50 100KPSS 50.150/P 7032 50 150KPSS 50.200/P 7032 50 200

K23

K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.

EANcode

954889954896954902

Weight 100 units

pc

303540

During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.

Page 7: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

60

CABLE TRAY SYSTEM KP

GRP elbow 45°, small radiuspressed, with interlocking coupler

KPC 50.100/P

7032 50 100 100KPC 50.150/P 7032 50 150 175KPC 50.200/P 7032 50 200 200

K23

K23K23

Item ref. RAL colour

Height WidthB

Radius R

mm mm mm

Min. pack.

1 p.1 p.1 p.

EANcode

953585953592953608

Weight 100 units

pc

153040

During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.

GRP elbow 90°, large radiuspressed, with interlocking coupler

KPB 50.100/P

7032 50 100 125 100KPB 50.150/P 7032 50 150 200 175KPB 50.200/P 7032 50 200 225 200

K23

K23K23

Item ref. RAL colour

Height WidthB

C Radius R

mm mm mm mm

Min. pack.

1 p.1 p.1 p.

EANcode

953349953356953363

Weight 100 units

pc

306080

During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.

GRP changing elevationpressed, in 2 pieces, with interlocking coupler

Composed with different pieces, the changing elevation can be mounted in different heights

KPET 50.100/P

7032 50 100 160 480 800KPET 50.150/P 7032 50 150 160 480 800KPET 50.200/P 7032 50 200 160 480 800

K23

K23K23

Item ref. RAL colour

Height WidthB

HeightH1

HeightH2

HeightH3

mm mm mm mm mm

Min. pack.

1 p.1 p.1 p.

EANcode

954513954520954537

Weight 100 units

pc m/

180184259

During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.The part height depends on the height and the configuration usedH1 = 160 mm =>L1 = 785 mm ( a cut is necessary )H2 = 480 mm =>L2 = 1100 mmH3 = 800 mm =>L3 = 970 mm

GRP vertical inside elbowpressed, with interlocking coupler

KPBI 50.100/P

7032 50 100KPBI 50.150/P 7032 50 150KPBI 50.200/P 7032 50 200

K23

K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.

EANcode

954278954285954292

Weight 100 units

pc

405060

During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.

Page 8: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

61

GRP vertical outside elbowpressed, with interlocking coupler

KPBA 50.100/P

7032 50 100KPBA 50.150/P 7032 50 150KPBA 50.200/P 7032 50 200

K23

K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.

EANcode

954216954223954230

Weight 100 units

pc

304050

During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.

Page 9: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

62

CABLE TRAY SYSTEM KP

GRP cable trayspultruded, perforated

L = fixing distance (m)

Load

q (k

N/m

)

Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5 from thesupport. If this distance is not respected, it is necessary to raise the deflection values by approx. 30%.

The splice plates KPGH…/ KPIH… V4A are not included in the cables trays, please order themseparately.

Load diagram : q = load evenly distributed cables (according to DIN EN IEC 61537 standard)

KPL 80.100

7032 80 100 2,5KPL 80.150 7032 80 150 2,5KPL 80.200 7032 80 200 2,5KPL 80.300 7032 80 300 3,2KPL 80.100/6 7032 80 100 2,5KPL 80.150/6 7032 80 150 2,5KPL 80.200/6 7032 80 200 2,5KPL 80.300/6 7032 80 300 3,2

K23

K23K23K23K23K23K23K23

Item ref. RAL colour

Height WidthB

Materialthickness

(th)mm mm mm

Min. pack.

3 m3 m3 m3 m6 m6 m6 m6 m

EANcode

952595952601952618952625952670952687952694952700

Weight 100 units

m

180200234355180200234355

Due to the expansion of the material, the following points during installation must be observed :The supporting systems must not be fixed close to the splice platesFor fixing the cables trays on brackets, you need to drill a 9 mm diameter hole for the fixing of thecable tray base with bolts M6x20 V4AWhen fixing the splice plates KPGH…, an expansion distance of about 3 mm must be considered.

GRP cable trayspultruded, not perforated

The splice plates KPGH…/ KPIH… V4A are not included in the cables trays, please order themseparately.

KP 80.100

7032 80 100 2,5KP 80.150 7032 80 150 2,5KP 80.200 7032 80 200 2,5KP 80.300 7032 80 300 3,2KP 80.100/6 7032 80 100 2,5KP 80.150/6 7032 80 150 2,5KP 80.200/6 7032 80 200 2,5KP 80.300/6 7032 80 300 3,2

K23

K23K23K23K23K23K23K23

Item ref. RAL colour

Height WidthB

Materialthickness

(th)mm mm mm

Min. pack.

3 m3 m3 m3 m6 m6 m6 m6 m

EANcode

952434952441952458952465952519952526952533952540

Weight 100 units

m

148200240363148200240363

Due to the expansion of the material, the following points during installation must be observed :The supporting systems must not be fixed close to the splice platesFor fixing the cables trays on brackets, you need to drill a 9 mm diameter hole for the fixing of thecable tray base with bolts M6x20 V4AWhen fixing the splice plates KPGH…, an expansion distance of about 3 mm must be considered.

Page 10: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

63

End cap for cable traypultruded

for the cable tray ends

Used for: Cable tray H50, H80, KP…, KPL… and cable truncking LFG…

Mounting accessories required : 2 bolts M6x16 V4A ( to be ordered separately )

KPKE 80.100

7032 80 100KPKE 80.150 7032 80 150KPKE 80.200 7032 80 200KPKE 80.300 7032 80 300

K23

K23K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.1 p.

EANcode

955428955435955442955459

Weight 100 units

pc

8111320

Clipsable splice platepultruded, horizontal

Need: 2 pieces for each cut

for the connection of cable trays and the fittings H80, with splice plates H80should be clipped on both cable trays sides.

KPGH 80

7032 69K23

Item ref. RAL colour

Height

mm

Min. pack.

1 set

EANcode

955718

Weight 100 units

22,5

During the assembly, an expansion gap of 3 mm for dilatation must be considered.

Separatorpultruded

The divider KPT80 is delivered not mounted, it can be fixed in the cable tray with a bolt M 6x16V4A each meter.The divider KPT80/M can be delivered pre-mounted (riveted ), the position inside the cabletray must be defined in the purchase order.

to separate cables with different functions and / or to separate voltages

KPT 80

7032 65KPT 80/M 7032 65

K23

K23

Item ref. RAL colour

Height

mm

Min. pack.

3 m3 m

EANcode

953134953158

Weight 100 units

m

4242

GRP tee junction for cable tray, large radiuspressed, with interlocking coupler

KPST 80.100/P

7032 80 100KPST 80.150/P 7032 80 150KPST 80.200/P 7032 80 200KPST 80.300/P 7032 80 300

K23

K23K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.1 p.

EANcode

954759967629954766954773

Weight 100 units

pc

78,078,090,0

108,5

During the assembly, every fitting must be supported at each end, at the cable entry. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.

GRP elbow 45°, small radiuspressed, with interlocking coupler

The piece is provided with a sleeve riveted on one side only.

KPC 80.100/P

7032 80 100 100KPC 80.150/P 7032 80 150 175KPC 80.200/P 7032 80 200 200KPC 80.300/P 7032 80 300 225

K23

K23K23K23

Item ref. RAL colour

Height WidthB

Radius R

mm mm mm

Min. pack.

1 p.1 p.1 p.1 p.

EANcode

953615967636953622953639

Weight 100 units

pc

22324585

During the assembly, every fitting must be supported at each end, at the cable entry. To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.

Page 11: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

64

CABLE TRAY SYSTEM KP

GRP elbow 90°, large radiuspressed, with interlocking coupler

KPB 80.100/P

7032 80 100 125 100KPB 80.150/P 7032 80 150 200 175KPB 80.200/P 7032 80 200 225 200KPB 80.300/P 7032 80 300 250 225

K23

K23K23K23

Item ref. RAL colour

Height WidthB

C Radius R

mm mm mm mm

Min. pack.

1 p.1 p.1 p.1 p.

EANcode

953370967643953387953394

Weight 100 units

pc/

41,565,090,0

170,0

During the assembly, every fitting must be supported at each end, and also in the center.To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.

GRP changing elevationpressed, in 2 pieces, with interlocking coupler

Composed with different pieces, the changing elevation can be mounted in different heights

KPET 80.100/P

7032 80 100 160 480 800KPET 80.150/P 7032 80 150 160 480 800KPET 80.200/P 7032 80 200 160 480 800KPET 80.300/P 7032 80 300 160 480 800

K23

K23K23K23

Item ref. RAL colour

Height WidthB

HeightH1

HeightH2

HeightH3

mm mm mm mm mm

Min. pack.

1 p.1 p.1 p.1 p.

EANcode

954544967650954551954568

Weight 100 units

pc/

190230270350

During the assembly, every fitting must be supported at each end, at the cable entry. To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.The part height depends on the height and the configuration usedH1 = 160 mm =>L1 = 785 mm ( a cut is necessary )H2 = 480 mm =>L2 = 1100 mmH3 = 800 mm =>L3 = 970 mm

GRP vertical inside elbowpressed, with interlocking coupler

KPBI 80.100/P

7032 80 100KPBI 80.150/P 7032 80 150KPBI 80.200/P 7032 80 200KPBI 80.300/P 7032 80 300

K23

K23K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.1 p.

EANcode

954308967667954315954322

Weight 100 units

pc

506580

102

During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.

GRP vertical outside elbowpressed, with interlocking coupler

KPBA 80.100/P

7032 80 100KPBA 80.150/P 7032 80 150KPBA 80.200/P 7032 80 200KPBA 80.300/P 7032 80 300

K23

K23K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.1 p.

EANcode

954247967674954254954261

Weight 100 units

pc

40506080

During the assembly, every fitting must be supported at each end, at the cable entry. To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.

Page 12: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

65

NOTES

Page 13: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

66

CABLE TRAY SYSTEM COVERS KP

GRP cover for cable traypultruded

for cable trays

Used for: GRP cable trays H40, H50 and H80 KP… and KPL… (perforated)

KPD 60

7032 60 2,0KPD 100 7032 100 2,5KPD 150 7032 150 2,5KPD 200 7032 200 2,5KPD 300 7032 300 2,5

K23

K23K23K23K23

Item ref. RAL colour

WidthB

Materialthickness

(th)mm mm

Min. pack.

3 m3 m3 m3 m3 m

EANcode

956241956258956265956272956289

Weight 100 units

pc m/

29,152,075,0

100,0145,0

To ensure a correct and strong installation of the cable trays and covers , a minimum distance of3 mm for dilatation must be considered for both parts. Fast fix clip of covers. In extreme windy conditions (strong winds, storms for example), werecommend to add cover clips DF…V4A.

GRP cover for horizontal elbow 45°, small radiuspressed

Used for: Elbow 45° H50, H80 and H110 mm, KKC… and KPC…/P

KKCD 100

7032 100KKCD 150 7032 150KKCD 200 7032 200KKCD 250 7032 250KKCD 300 7032 300KKCD 400 7032 400KKCD 500 7032 500KKCD 600 7032 600

K23

K23K23K23K23K23K23K23

Item ref. RAL colour

WidthB

mm

Min. pack.

1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.

EANcode

956456956463956470956487956494956500956517956524

Weight 100 units

pc

1223335051

138150173

Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.

Cover for horizontal elbow 90°, large radiuspressed

Used for: Horizontal elbow 90°, large radius, H50, H80 and H110, KKB… and KPB…/P

KKBD 100

7032 100KKBD 150 7032 150KKBD 200 7032 200KKBD 250 7032 250KKBD 300 7032 300KKBD 400 7032 400KKBD 500 7032 500KKBD 600 7032 600

K23

K23K23K23K23K23K23K23

Item ref. RAL colour

WidthB

mm

Min. pack.

1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.

EANcode

956371956388956395956401956418956425956432956449

Weight 100 units

pc

19,543,068,097,0

115,0241,0334,0403,0

Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.

GRP cover for vertical inside elbowpressed

Used for: Vertical inside elbow 50 mm high, KKBI… and KPBI…/P

KKBID 50.050

7032 50 50KKBID 50.100 7032 50 100KKBID 50.150 7032 50 150KKBID 50.200 7032 50 200KKBID 50.300 7032 50 300

K23

K23K23K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.1 p.1 p.

EANcode

956814956821956838956845956852

Weight 100 units

pc

520425063

Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.

Page 14: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

67

GRP cover for vertical inside elbowpressed

Used for: Vertical inside elbow 80 mm high, KKBI… and KPBI…/P

KKBID 80.100

7032 80 100KKBID 80.150 7032 80 150KKBID 80.200 7032 80 200KKBID 80.250 7032 80 250KKBID 80.300 7032 80 300KKBID 80.400 7032 80 400KKBID 80.500 7032 80 500KKBID 80.600 7032 80 600

K23

K23K23K23K23K23K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.

EANcode

956869956876956883956890956906956913956920956937

Weight 100 units

pc

18,024,533,040,045,561,073,095,0

Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.

GRP cover for vertical outside elbowpressed

Used for: Vertical outside elbow H50 mm, KKBA… and KPBA…/P

KKBAD 50.050

7032 50 50KKBAD 50.100 7032 50 100KKBAD 50.150 7032 50 150KKBAD 50.200 7032 50 200KKBAD 50.300 7032 50 300

K23

K23K23K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.1 p.1 p.

EANcode

956623956630956647956654956661

Weight 100 units

pc

7,810,042,051,065,0

Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.

GRP cover for vertical outside elbowpressed

Used for: Vertical outside elbow H80 mm, KKBA… and KPBA…/P

KKBAD 80.100

7032 80 100KKBAD 80.150 7032 80 150KKBAD 80.200 7032 80 200KKBAD 80.250 7032 80 250KKBAD 80.300 7032 80 300KKBAD 80.400 7032 80 400KKBAD 80.500 7032 80 500KKBAD 80.600 7032 80 600

K23

K23K23K23K23K23K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.

EANcode

956678956685956692956708956715956722956739956746

Weight 100 units

pc

29,539,051,061,072,090,0

120,0136,0

Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.

GRP cover for changing elevationpressed

1 KKETD is composed of :- 1 GRP cover for inside elbow- 1 GRP cover for outside elbowUsed for: Changing elevation H50 mm KKET… and KPET…/P

KKETD 50.100

7032 50 100KKETD 50.150 7032 50 150KKETD 50.200 7032 50 200KKETD 50.300 7032 50 300

K23

K23K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.1 p.

EANcode

957002957019957026957033

Weight 100 units

pc

20414060

Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.

Page 15: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

68

CABLE TRAY SYSTEM COVERS KP

GRP cover for changing elevationpressed

1 KKETD is composed of :- 1 GRP cover for inside elbow- 1 GRP cover for outside elbowUsed for: Changing elevation H50 mm KKET… and KPET…/P

KKETD 80.100

7032 80 100KKETD 80.150 7032 80 150KKETD 80.200 7032 80 200KKETD 80.250 7032 80 250KKETD 80.300 7032 80 300KKETD 80.400 7032 80 400KKETD 80.500 7032 80 500KKETD 80.600 7032 80 600

K23

K23K23K23K23K23K23K23

Item ref. RAL colour

Height WidthB

mm mm

Min. pack.

1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.

EANcode

957040957057957064957071957088957095957101957118

Weight 100 units

pc

23,531,740,544,047,061,098,0

120,0

Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.

GRP cover for tee junction, large radiuspressed, with interlocking coupler

Used for: Cover for tee junction for H50, H80 and H110 mm, KKST… and KPST…/P

KKSTD 100

7032 100KKSTD 150 7032 150KKSTD 200 7032 200KKSTD 250 7032 250KKSTD 300 7032 300KKSTD 400 7032 400KKSTD 500 7032 500KKSTD 600 7032 600

K23

K23K23K23K23K23K23K23

Item ref. RAL colour

WidthB

mm

Min. pack.

1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.

EANcode

957187957194957200957217957224957231957248957255

Weight 100 units

pc

354252636578

100118

Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.

Tee junction cover, small radiuspressed, with interlocking coupler

Used for: Tee junction for H50 and H80 mm, KKSS… and KPSS…/P

KKSSD 50

7032 50KKSSD 100 7032 100KKSSD 150 7032 150KKSSD 200 7032 200KKSSD 250 7032 250KKSSD 300 7032 300

K23

K23K23K23K23K23

Item ref. RAL colour

WidthB

mm

Min. pack.

1 p.1 p.1 p.1 p.1 p.1 p.

EANcode

957262957279957286957293957309957316

Weight 100 units

pc

5,08,09,5

13,014,515,5

Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.

GRP cover for right hand reductionpressed

Used for: Right hand reduction H50, H80 and H110 mm, KKRR…

KKRRD 200

7032 200KKRRD 300 7032 300KKRRD 400 7032 400KKRRD 500 7032 500KKRRD 600 7032 600

K23

K23K23K23K23

Item ref. RAL colour

WidthB

mm

Min. pack.

1 p.1 p.1 p.1 p.1 p.

EANcode

957378957385957392957408957415

Weight 100 units

pc

50,579,0

119,0131,0160,0

Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.

Page 16: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

69

GRP cover for left hand reductionpressed

Used for: Reduction H50, 80 and 110 mm, KKRL…

KKRLD 200

7032 200KKRLD 300 7032 300KKRLD 400 7032 400KKRLD 500 7032 500KKRLD 600 7032 600

K23

K23K23K23K23

Item ref. RAL colour

WidthB

mm

Min. pack.

1 p.1 p.1 p.1 p.1 p.

EANcode

957323957330957347957354957361

Weight 100 units

pc

4975

110147160

Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.

Cover fixing clipstainless steel

for fixing the cables tray covers and fittings

Used for: Cable tray cover KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... and KKRRD...

DF 50 E4

55DF 80 E4 85

E4

E4

Item ref. Height

mm

Min. pack.

50 p.50 p.

EANcode

957873957880

Weight 100 units

pc.

1,72,1

Under normal conditions, it is recommended to mount 1 clip each meter alternatively every 3 meters.Under extreme weather conditions, such as strong winds or storms, the quantity of clips must beincreased.

Cover fixing

Used for: Cover for cable tray KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... und KKRRD…

DF M

K01

Item ref. Min. pack.

50 p.

EANcode

957927

Weight 100 units

pc.

0,2

For fixing the cover, it is necessary to drill a 8,2 mm diameter hole for the diameter. In extremeweather conditions such as strong winds, for example, the quantity of clips must be increased.

Cover fixing

Used for: Cover for cable tray KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... und KKRRD…

DFUB 5.5X19 E4

N E4

Item ref. Min. pack.

50 p.

EANcode

062065

Weight 100 units

0,64

For fixing the cover, it is necessary to drill a 8,2 mm diameter hole for the diameter. In extremeweather conditions such as strong winds, for example, the quantity of clips must be increased.

Page 17: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

70

CABLE TRAY SYSTEM ACCESSOIRES KP

Rack for cablespressed, standard

The rack for cables KR is delivered not mounted and must be screwed on the cable tray basewith 2 bolts M…V4A at each meter.The rack for cables KR…/M can be delivered pre-mounted (riveted), the position must bedefined in the purchase order.

for fixing the cables with cable ties in the vertical rack

Used for: Cable tray H50, H80 and H110 mm, KK…, KKL…, KP…, KPL…

The mounting straps must be ordered separately

KR 100

7032 100KR 150 7032 150KR 200 7032 200KR 250 7032 250KR 300 7032 300KR 400 7032 400KR 500 7032 500KR 600 7032 600KR 100/M 7032 100KR 150/M 7032 150KR 200/M 7032 200KR 250/M 7032 250KR 300/M 7032 300KR 400/M 7032 400KR 500/M 7032 500KR 600/M 7032 600

K23

K23K23K23K23K23K23K23K23K23K23K23K23K23K23K23

Item ref. RAL colour

WidthB

mm

Min. pack.

1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.

EANcode

955466955473955480955497955503955510955527955534955541955558955565955572955589955596955602955619

Weight 100 units

pc

2,43,14,06,06,7

11,016,020,02,43,14,06,06,7

11,016,020,0

For a wall or ceiling mounting, the cable tray supports must be adjusted properly in order to obtain allcable trays on a straight line.

Separating studpultruded

Not suitable when the cable tray is mounted vertically (not horizontally)

for an easy mounting of cables and connections

TB

K01

Item ref. Min. pack.

1 p.

EANcode

957934

Weight 100 units

m

1

When mounting the separating stud, it is necesary to drill a 10 mm hole diameter in the base.

Dome head boltIncluded nut and washer

Also named M6x16V4A for FKM 6x16 E4, M6x20V4A for FKM 6x20 E4, M8x20PA6 for FKM 8x20K01, M10x30V4A for SKM 10x30 E4

FKM 6X16 E4

6 16FKM 6X20 E4 6 20

E4

E4

Item ref. ThreadM

LengthL

mm

Min. pack.

100 p.100 p.

EANcode

962693962709

Weight 100 units

pc

1,21,4

Dome head boltIncluded nut and washer

Also named M6x16V4A for FKM 6x16 E4, M6x20V4A for FKM 6x20 E4, M8x20PA6 for FKM 8x20K01, M10x30V4A for SKM 10x30 E4

FKM 8X20 K01

8 20K01

Item ref. ThreadM

LengthL

mm

Min. pack.

100 p.

EANcode

962716

Weight 100 units

pc

0,4

Hexagon head boltIncluded nut and washer

Also named M6x16V4A for FKM 6x16 E4, M6x20V4A for FKM 6x20 E4, M8x20PA6 for FKM 8x20K01, M10x30V4A for SKM 10x30 E4

SKM 10X30 E4

10 30SKM 10X40 E4 10 40

E4

E4

Item ref. ThreadM

LengthL

mm

Min. pack.

100 p.100 p.

EANcode

962730962747

Weight 100 units

pc

4,55,1

70

ACCESSOIRES POUR SYSTÈME DE CHEMINS DE CÂBLES KP

Ratelier pour câblespressé, standard

Le râteau pour câbles KR est livré non-monté et à visser dans le fond du socle à l'aide de 2boulons M...V4A par mètre.Le râteau pour câbles KR.../M peut être pré-monté en usine (riveté), le positionnement est àdéfinir au moment de la commande.

pour la fixation des câbles à l'aide de colliers dans le ratelier vertical

Utilisable pour : Chemins de câbles H50,H80 et H110 mm, KK..., KKL..., KP..., KPL...

Les colliers de fixation doivent être commandés séparément

KR 100

7032 100KR 150 7032 150KR 200 7032 200KR 250 7032 250KR 300 7032 300KR 400 7032 400KR 500 7032 500KR 600 7032 600KR 100/M 7032 100KR 150/M 7032 150KR 200/M 7032 200KR 250/M 7032 250KR 300/M 7032 300KR 400/M 7032 400KR 500/M 7032 500KR 600/M 7032 600

K23

K23K23K23K23K23K23K23K23K23K23K23K23K23K23K23

Réf. Art. Cou-leurRAL

LargeurB

mm

Coli-sage mini.

1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.

CodeEAN

955466955473955480955497955503955510955527955534955541955558955565955572955589955596955602955619

Poids100uni.

pc

kg

2,43,14,06,06,7

11,016,020,02,43,14,06,06,7

11,016,020,0

En cas de montage mural ou au plafond, il faut prendre soin de poser correctement le chemin decâbles sur son support afin de former une surface plane

Tige de séparationpultrudée

Non adapté lorsque le chemin de câbles est monté à champ.

pour le montage facile de câbles et de liaisons

TB

K01

Réf. Art. Coli-sage mini.

1 p.

CodeEAN

957934

Poids100uni.

m

kg

1

Lors du montage, il est nécessaire de percer un trou traversant de diametre 10 mm pour l'installationdes tiges de séparation.

Bouloninclus écrou et rondelle

Egalement appelé : M6x16V4A pour FKM 6x16 E4, M6x20V4A pour FKM 6x20 E4, M8x20PA6pour FKM 8x20 K01, M10x30V4A pour SKM 10x30 E4

FKM 6X16 E4

6 16FKM 6X20 E4 6 20

E4

E4

Réf. Art. FiletageM

Long.L

mm

Coli-sage mini.

100 p.100 p.

CodeEAN

962693962709

Poids100uni.

pc

kg

1,21,4

Bouloninclus écrou et rondelle

Egalement appelé : M6x16V4A pour FKM 6x16 E4, M6x20V4A pour FKM 6x20 E4, M8x20PA6pour FKM 8x20 K01, M10x30V4A pour SKM 10x30 E4

FKM 8X20 K01

8 20K01

Réf. Art. FiletageM

Long.L

mm

Coli-sage mini.

100 p.

CodeEAN

962716

Poids100uni.

pc

kg

0,4

Page 18: CABLE TRAY SYSTEM GFK Fittings - Startseite - · PDF fileKP Cable trays Dividers Fittings Covers Accessoires Cable tray systems available in height 50 80 110 System KP 54 CABLE TRAY

71

NOTES


Recommended